1

Couplage d'une pile à combustible avec des supercapacités pour étudier les gains en termes de rendement et de durée de vie / Direct hybridization of PEMFC with small aqueous supercapacitors

Ait Hammou Taleb, Saïd 31 January 2019 (has links)
Les piles à combustible sont des convertisseurs électrochimiques. Elles convertissent l’énergie chimique en une énergie électrique directement disponible grâce à une réaction d’oxydoréduction. Dans notre cas, nous nous intéressons aux piles à membrane protonique plus communément appelées PEMFC (Proton Exchange Membrane Fuel Cell) qui fonctionne à l’hydrogène. Ce type de pile domine le marché puisqu’elles conviennent à de nombreuses applications portables et stationnaires. Si l’on s’intéresse aux PAC pour des utilisations stationnaires, des durées de vie supérieures à 10 000 h peuvent être atteintes. Cependant, celles-ci se réduisent significativement pour des applications de type transport avec de fréquents arrêts et démarrages ainsi que d’importantes variations de puissance : dans ce cas, 3000 h de fonctionnement semblent constituer une limite difficile à dépasser. En régime instationnaire, les fluctuations de puissance impactent les conditions opératoires de la pile et génèrent des phénomènes locaux accélérant son vieillissement. L’intérêt de l’hybridation est d’élargir le champ d’application des systèmes pile à combustible en les rendant capables de répondre aux exigences des applications de type transport. Dans notre cas, il s’agit d’une structure parallèle, avec comme source d’énergie principale, une pile à combustible assistée d’un moyen de stockage, les supercapacités. A travers nos travaux, nous avons recherché à déterminer les avantages que peut offrir l’hybridation en termes de simplification de système : identifier les composants ou sous-systèmes qui limitent la dynamique de la pile à combustible, comprendre les mécanismes mis en jeu et étudier les solutions que peut offrir l’association des SC à la PAC. L’ajout de supercapacités, en tant que sources secondaires, permet d’obtenir une densité de puissance plus élevée et ainsi d’adapter le système PAC à des applications instationnaires. Nous avons également observé qu’il est possible de concevoir des systèmes fiables en limitant le vieillissement des piles. Les travaux ont permis de tester des supercapacités planes élaborées par l’IMN. L’intérêt est de pouvoir produire des supercapacités planes performantes à bas coût et non néfaste pour l’environnement / Fuel cell are an electrochemical devices wich convert chemical energy into electricity. In this study we focus on PEMFC Proton Exchange Membrane Fuel Cells fede by hydrogen and air. This kind of fuel cell has many advantages and show extensive application potentials. If PEMFC exhibits good power capability during steady-state operation, the slow response during transient peak power demands has restrained them for being used in large-scale and high-power transportation applications, such as automobive. To overcome these difficulties, a variety of research has been carried out on the development of hybrid systems based on supercapacitors or batteries. In this work, we study the effect of passive hybridization to improve the system performance and reliability, more specifically during steep load variations. We show that SC can provide a sufficient amount of power to the system during the short time needed by the gas supply lines to respond to an increase in power or current density. This makes it possible to always feed the fuel cell with the right amount of gas without anticipating current peaks or load variations. Flat supercapacitors were also designed and made within the framework of this project. The aim was to design cheap and safe SC with materials like activated carbon electrode and LiNO3 as the electrolyte. In this study we also showed how a direct passive hybridization of PEMFC with small aqueous supercapacitors brings to the design of more efficient, simple and reliable FC systems. By using transient load (Heaviside steps), we showed that the direct hybridization of PEMFC with SC allows to extend its lifetime
2

Hybridation directe d’une pile à combustible PEM et d’un organe supercapacitif de stockage : étude comparative du vieillissement en cyclage urbain, et gestion optimale de la consommation d’hydrogène / Direct hybridization of a PEM fuel cell and a supercapacitor storage device : Comparative study of aging in urban cycling, and optimal management of hydrogen consumption

Arora, Divyesh 17 September 2019 (has links)
La pile à combustible (FC) est peu adaptée aux variations brusques de puissance rencontrées dans les applications transport. L’hybridation de la pile à un supercondensateur (SC) a alors été étudiée, puisque cet organe de stockage capacitif permet de gérer les transitoires de puissance. L’hybridation est directe/passive, permettant ainsi de réduire le volume, la masse et le coût du système. Initialement, la faisabilité et l’impact de la taille du SC sur la performance de la FC en mono-cellule ont été examinés numériquement. Cette modélisation montre que l’augmentation de la taille du SC renforce l’effet de lissage induit par l’utilisation du SC sur le courant de la FC. Il en résulte des variations lentes et une réduction des amplitudes de courant et de tension, une diminution du courant efficace de la FC, et donc des pertes électriques de celle-ci. L’hybridation de la FC, comparativement à son fonctionnement seule, permet en outre de réduire la surconsommation en H2 de près de 50 % dans les mêmes conditions opératoires. Ces résultats ont été validés par des essais expérimentaux réalisés en mono-cellule et 3-cellules de 100 cm2 hybridée ou non. Par la suite, toujours en utilisant le protocole de cyclage urbain (FC-DLC), la durabilité de la FC a été étudiée lors d’essais de longue durée. La durabilité de la FC, qu’elle soit hybridée ou non, est la même. L’hybridation n’améliore donc pas la durée de vie de la FC mais ne lui nuit pas non plus. Par la suite, afin d’encore réduire la surconsommation en H2 en longue durée cyclage, différentes stratégies ont été étudiées : diminution du débit minimum des gaz imposé par le cyclage et diminution du coefficient de surstœchiométrie en H2. Ces changements n’ont pas d’influence sur la durabilité de la pile hybridée et ont permis de réduire à 10 % la surconsommation en hydrogène. La FC non hybridée, quant à elle, a vu sa durabilité divisée par deux lors de la diminution des débits minimum et ne fonctionnait pas avec le coefficient de surstœchiométrie ramené à 1,1. Ensuite, les travaux ont été étendus à un stack FC de forte puissance (Système Ballard de 1,2 kW) hybridé à deux modules de SC de 165 F (Maxwell Technologies). En final, un système hybride de 34 kW (FC de 10 kW et SC de 566.67 F) a montré des performances suffisantes pour une application transport urbain et péri-urbain. De plus, comparativement à une pile de 34 kW 21 % d’hydrogène sont économisés et l'investissement des équipements peut être réduit de près 50 % / The fuel cell (FC) is poorly adapted to the sudden variations in power encountered in transport applications. The FC hybridization to a supercapacitor (SC) was then studied, since this capacitive storage device allows to manage the power transients. Hybridization is direct/passive, thus reducing the volume, mass and cost of the system. Initially, the feasibility and the impact of SC size on FC performance have been examined numerically. Theoretical investigations show that increasing the size of SC enhances the smoothing effect introduced by the supercapacitor on FC current. This results into slow variations and reduction in both current and voltage amplitudes, a decrease in the fuel cell’s effective current, and therefore in FC electrical losses. Hybridization, compared to its FC operation alone, still reduces hydrogen overconsumption by nearly 50 % under the same operating conditions. These results have been validated by experimental tests carried out on a 100 cm2 single FC and a 3 cell stack. Later, the durability of the FC system has been investigated through long term tests. These durability tests have been conducted on the 100 cm2 single FC test bench using urban cycling protocol (FC-DLC), for both hybridized and unhybridized FC system, with continuous evaluation of degradation extent and causes. These tests suggest no detrimental impact on durability of the FC. For these two operating modes, a progressive aging of the gas diffusion layer seems to appear. Subsequently, in order to further reduce the overconsumption of hydrogen in long-term FC-DLC cycling, different strategies were studied: reducing the minimum gas flow rate imposed by FC-DLC cycling from 0.2 to 0.05 A cm-2, and reducing the hydrogen overstoichiometry coefficient from 1.2 to 1.1. These changes have no influence on the durability of the hybrid cell and have reduced hydrogen overconsumption to 10 %. On the contrary, in case of the unhybridized FC, durability was halved as minimum flows were reduced and it did not work when the overstoichiometry reduced coefficient. Further, work has been extended to high power FC systems (1.2 kW FC system, hybridized with two modules of 165 F, SC module). Finally, the FC downsizing has been demonstrated from 34kW FC system to hybrid source system of 10kW FC hybridized with 566.64 F SC, presenting 21 % hydrogen saving and nearly 50 % net cost savings.
3

Etude de dégradations des performances de Piles à Combustible PEM BT alimentées en H2/O2 lors de campagnes d'endurance : du suivi de l'état de santé en opération à la modélisation du vieillissement / Study of the performance degradation of low temperature PEM fuel cells fed with H2/O2 during ageing campaigns : from the online state of health monitoring to the ageing modeling

Tognan, Malik 12 September 2018 (has links)
Les travaux développés dans cette thèse traitent de la thématique du vieillissement des Piles à Combustible (PàC) à Membranes Echangeuses de Protons Basse Température (PEM BT). L’utilisation d’une PàC dans un contexte stationnaire à l’intérieur d’une batterie H2 (tandem PàC/Electrolyseur avec un étage de stockage H2 voire O2) est envisagée dans le cadre du déploiement d’un micro-réseau insulaire basé sur des sources d’énergie renouvelables (éolien et photovoltaïque). Deux aspects connexes associés à l’utilisation de la PàC et à son vieillissement dans cet environnement sont investigués dans ce travail de thèse : d’une part la manière dont les performances de la PàC et son rendement vont se dégrader au cours du temps et d’autre part les méthodes et outils qui vont être utilisés pour évaluer son état de santé durant sa période d’activité. La première de ces deux thématiques est abordée via l’étude d’une base de données d’essais en endurance à courant constant effectués sur des prototypes de stack PEM BT fonctionnant en H2/O2. L’hétérogénéité du vieillissement pour les différents stacks testés est mise en avant, de même que le découplage entre les pertes d’étanchéité interne et les dégradations des performances en tension au courant nominal durant les différentes campagnes. Une méthodologie proposant une dissociation des dynamiques réversibles et irréversibles de décroissance de la tension de la PàC au cours du temps est ensuite exposée et sert de base à la construction d’un modèle de dégradation de la tension sur un fonctionnement à courant fixe. Le modèle montre des résultats encourageants et une perspective liée à son utilisation dans le cadre du pronostic est suggérée. La question de la sensibilité du vieillissement aux variations dynamiques de la charge est ensuite abordée de manière complémentaire à ces essais d’endurance (effectués à charge constante) via une campagne de vieillissement effectuée sur des monocellules hybridées ou non directement par des supercondensateurs et cyclant sur un profil de courant dynamique. Une comparaison des évolutions des performances des monocellules au cours du temps dans les deux cas (hybridé et non-hybridé) est effectuée et met en avant l’effet du cyclage dynamique sur la dégradation des performances des PàC. La deuxième thématique touchant les méthodes et outils dédiés à l’évaluation de l’état de santé de la PàC durant son fonctionnement est introduite dans la suite de ces travaux en se penchant notamment sur une des causes majeures de la fin de vie des PàC : l’accroissement du crossover d’H2 vers l’O2 lié à la perte d’étanchéité interne de la membrane. Des mesures de tension à vide (OCV) effectuées lors de phases d’arrêt/démarrage sont scrutées a posteriori pour une des campagnes de la base de données d’essais en endurance. L’objectif est de rechercher des éventuelles corrélations entre l’accroissement des fuites internes et l’évolution de ces mesures au cours du temps afin de développer des potentiels indicateurs des fuites internes. Une séquence opératoire de mise en gaz mettant en avant un lien entre le niveau de crossover d’H2 et la vitesse d’effondrement de l’OCV pour certaines cellules du stack est identifiée et reproduite à l’occasion d’une campagne complémentaire d’essais. Une dernière partie du manuscrit est finalement consacrée à une approche théorique prospective dédiée à l’intégration d’un phénomène parasite, l’oxydation du Pt, dans la modélisation des performances statiques et dynamiques d’une PàC. Les retombées attendues portent sur l’amélioration de l’interprétation des caractérisations menées régulièrement (EIS, OCV, balayages sinus de forte amplitude aux très basses fréquences…), permettant le suivi du vieillissement. / This thesis work deals with the thematic of the Low Temperature Proton Exchange Membrane (PEM LT) Fuel Cell (FC) aging. The use of a FC inside a H2 battery (association of a FC, an electrolyzer and H2 / O2 tanks) in a stationary context is considered in an island micro-grid based on renewable energies (wind and solar power). Two axes linked with the FC use and aging in this context are investigated in this work: one of the axes is centered in the study of the FC performance decrease dynamics over time and the other on the development of methods and tools dedicated to the state of health monitoring during the FC operation. The first thematic is introduced through the exploitation of several aging campaigns performed on PEM FC stack prototypes under constant current solicitations. The stacks considered are fed with pure O2 on the cathode side. A focus is made on the aging heterogeneity inside the stacks and a decoupling between the nominal voltage degradation dynamics and the development of the H2 internal leak with time is highlighted for the different stacks and campaigns. A generic methodology dissociating the reversible and the irreversible voltage losses dynamics is proposed and is further used as a basis to model the nominal voltage degradation with time. The model built in this way is showing encouraging results and its potential use for prognostic purpose is suggested. Whereas these investigations focus on the FC performance degradations under constant current solicitation, the impact of load current dynamic variations on the FC aging is also treated with an experimental study performed on single cells. An ageing campaign under a dynamic load profile is performed on several single cells directly hybridized or not by supercapacitors. The hybridized cells are cycling on an almost-constant current profile whereas the non-hybridized cells are cycling on a dynamic one. A comparison of the performances evolution with time in both cases (hybridized and nothybridized) is done and highlights the effect of the dynamic cycling on the FC performance degradation. The second thematic dealing with the FC state of health evaluation is introduced with one of the main causes of the FC end-of-life: the development of the H2 internal leak between the anode and cathode compartments. Open Circuit Voltage (OCV) measurements performed during start-up and shut-down routines phases are scanned a posteriori in one of the aging campaign of the database. The objective is to seek some potential correlations between those OCV measurements and the H2 internal leak increase over time in order to develop internal leak indicators. A gases introduction operating sequence highlighting a link between the internal leak level and the OCV drift for some stack’s cells is identified during some start-up phases and reproduced during a complementary campaign. A last part of the manuscript is finally dedicated to the integration of a parasitic mechanism (the Pt oxidation) into the FC theoretical quasi-static and dynamic performance modeling. The model integrating this phenomenon is showing some abilities to explain and analyze several experimental features observed on classical performance characterization measurements (EIS, OCV measurements, large amplitude sinus sweep at very low frequency…), opening some perspectives for the FC state of health monitoring.