• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 9
  • 1
  • Tagged with
  • 11
  • 11
  • 6
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Simulação numérica da convecção natural no interior de um refrigerador doméstico

Kinoshita, Denise [UNESP] 15 April 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:39Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-04-15Bitstream added on 2014-06-13T19:30:01Z : No. of bitstreams: 1 kinoshita_d_me_ilha.pdf: 2189895 bytes, checksum: 18c800e5f3dc7c91ac3187a97f2410b9 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Neste trabalho realizou-se um estudo numérico do escoamento em gabinetes de refrigeradores domésticos operando em regime de convecção natural, usando-se o Método de Volumes Finitos. No procedmento numérico, o problema do acoplamento pressão-velocidade foi resolvido pelo algoritmo SIMPLE - Semi Implicit Method for Pressure Linked Equations para malha desencontrada. O esquema Power-Law foi utilizado como função de interpolação para os termos convectivo-difusivos e o TDMA-Tri Diagonal Matrix Algorithm foi usado para resolver os sistemas de equações algébricas. O gabinete do refrigerador foi modelado como uma cavidade tridimensional vazia sem prateleiras e o evaporador foi modelado como uma placa plana vertical com temperatura uniforme prescrita. O código numérico foi verificado parcialmente para problemas clássicos de convecção natural encontrados na literatura. Resultados experimentais preliminares para um refrigerador doméstico comercial de 350 l também foram levantados para a validação do código numérico. Após a validação do código numérico, as influências do posicionamento e temperatura do evaporador nos campos de temperatura e velocidade foram analisadas para três configurações do gabinete: gabinete sem gaveta de verdura, gabinete com gaveta de verdura e gabinete com gaveta de verdura com aberturas laterais. O modelo de gabinete com gaveta de verdura com aberturas laterais mostrou-se o mais adequado para estudar o problema. Nove posições do evaporador foram avaliadas, mostrando que o posicionamento na direção horizontal praticamente não influencia o campo de temperatura e velocidade do escoamento, enquanto que o posicionamento na direção vertical tem uma influencia significativa. Os campos de velocidade e temperatura e a carga térmica do evaporador... / A numerical study of the flow inside cabinets of domestic refrigerators working on natural convection regime is performed in this work using the Finite Volume Method as numerical procedure for solving the governing equations. The pressure-velocity coupling was solved using the algorithm SIMPLE–Semi Implicit Method for Pressure Linked Equations applied to a staggered mesh. The Power-Law scheme was used as interpolation function for the convective-diffusive terms, and the algorithm TDMA-Tri Diagonal Matrix Algorithm was used to solve the systems of algebraic equations. The model was applied to static refrigerator working in steady state with constant and uniform evaporator temperature. The cabinet was considered as an empty three-dimensional cavity without shelves and the evaporator was modeled as a vertical flat plate with prescribed uniform temperature. The numerical code was partially verified for classical natural convection problems usually found in the literature. Preliminary experimental results for a 350 l commercial domestic refrigerator were also obtained for validating the numerical code. After validating the numerical code, the influence of the positioning and temperature of the evaporator on the temperature and velocity fields were analyzed for three cabinet configurations: cabinet without vegetable drawer, cabinet with vegetable drawer, and cabinet with vegetable drawer presenting lateral openings. The model including the vegetable drawer with lateral openings showed to be the best model to study the problem. Nine evaporator positions were evaluated, showing that the positioning in the horizontal direction practically does not affect the temperature and velocity fields of the flow, while the vertical positioning has a significant effect on the results. The temperature and velocity... (Complete abstract click electronic access below)
2

Simulação numérica da convecção natural no interior de um refrigerador doméstico /

Kinoshita, Denise. January 2011 (has links)
Orientador: José Luiz Gasche / Banca: Cassio Roberto Macedo Maia / Banca: Sidnei José de Oliveira / Resumo: Neste trabalho realizou-se um estudo numérico do escoamento em gabinetes de refrigeradores domésticos operando em regime de convecção natural, usando-se o Método de Volumes Finitos. No procedmento numérico, o problema do acoplamento pressão-velocidade foi resolvido pelo algoritmo SIMPLE - Semi Implicit Method for Pressure Linked Equations para malha desencontrada. O esquema Power-Law foi utilizado como função de interpolação para os termos convectivo-difusivos e o TDMA-Tri Diagonal Matrix Algorithm foi usado para resolver os sistemas de equações algébricas. O gabinete do refrigerador foi modelado como uma cavidade tridimensional vazia sem prateleiras e o evaporador foi modelado como uma placa plana vertical com temperatura uniforme prescrita. O código numérico foi verificado parcialmente para problemas clássicos de convecção natural encontrados na literatura. Resultados experimentais preliminares para um refrigerador doméstico comercial de 350 l também foram levantados para a validação do código numérico. Após a validação do código numérico, as influências do posicionamento e temperatura do evaporador nos campos de temperatura e velocidade foram analisadas para três configurações do gabinete: gabinete sem gaveta de verdura, gabinete com gaveta de verdura e gabinete com gaveta de verdura com aberturas laterais. O modelo de gabinete com gaveta de verdura com aberturas laterais mostrou-se o mais adequado para estudar o problema. Nove posições do evaporador foram avaliadas, mostrando que o posicionamento na direção horizontal praticamente não influencia o campo de temperatura e velocidade do escoamento, enquanto que o posicionamento na direção vertical tem uma influencia significativa. Os campos de velocidade e temperatura e a carga térmica do evaporador... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: A numerical study of the flow inside cabinets of domestic refrigerators working on natural convection regime is performed in this work using the Finite Volume Method as numerical procedure for solving the governing equations. The pressure-velocity coupling was solved using the algorithm SIMPLE-Semi Implicit Method for Pressure Linked Equations applied to a staggered mesh. The Power-Law scheme was used as interpolation function for the convective-diffusive terms, and the algorithm TDMA-Tri Diagonal Matrix Algorithm was used to solve the systems of algebraic equations. The model was applied to static refrigerator working in steady state with constant and uniform evaporator temperature. The cabinet was considered as an empty three-dimensional cavity without shelves and the evaporator was modeled as a vertical flat plate with prescribed uniform temperature. The numerical code was partially verified for classical natural convection problems usually found in the literature. Preliminary experimental results for a 350 l commercial domestic refrigerator were also obtained for validating the numerical code. After validating the numerical code, the influence of the positioning and temperature of the evaporator on the temperature and velocity fields were analyzed for three cabinet configurations: cabinet without vegetable drawer, cabinet with vegetable drawer, and cabinet with vegetable drawer presenting lateral openings. The model including the vegetable drawer with lateral openings showed to be the best model to study the problem. Nine evaporator positions were evaluated, showing that the positioning in the horizontal direction practically does not affect the temperature and velocity fields of the flow, while the vertical positioning has a significant effect on the results. The temperature and velocity... (Complete abstract click electronic access below) / Mestre
3

Análise do desempenho de condensadores de parade-aquecida usados em refrigeradores domésticos /

Lima, Roniel de Souza. January 2017 (has links)
Orientador: André Luiz Seixlack / Resumo: Neste trabalho apresenta-se um modelo distribuído para análise de condensadores do tipo parede aquecida, hot-wall, usados em refrigeradores domésticos. Nesse modelo considera-se o escoamento do fluido refrigerante no interior do tubo do condensador e a transferência de calor entre a placa de revestimento externo do refrigerador e o ar ambiente. No modelo, inclui-se também a transferência de calor ao longo da fita de alumínio, usada para fixação do tubo na placa de revestimento externo e a transferência de calor através do isolamento térmico para o interior do compartimento refrigerado. O escoamento no interior do tubo é considerado unidimensional e dividido em três regiões: região monofásica de vapor superaquecido, região bifásica líquido-vapor e região monofásica de líquido sub-resfriado. O escoamento bifásico é analisado segundo o modelo homogêneo, ou seja, considerando condições de equilíbrio térmico e hidrodinâmico entre as fases. Considera-se também a queda de pressão do escoamento no interior do tubo. A fita de alumínio e a placa de revestimento externo são consideradas como aletas com extremidades adiabáticas. As equações do escoamento do fluido refrigerante: conservação da massa, quantidade de movimento e conservação de energia, são resolvidas por integração numérica e a equação de conservação de energia ao longo da fita de alumínio é resolvida pelo método de Volumes Finitos. O sistema de equações algébricas, decorrente do processo de discretização das equações difere... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This work presents a distributed model for the analysis of hot-wall condensers used in domestic refrigerators. In this model, the flow of refrigerant inside the condenser tube and the heat transfer between the outer coating plate of the refrigerator and the ambient air are considered. Also included in this model the heat transfer along the aluminum tape used to hold the tube to the outer coating plate and the heat transfer through the thermal insulation into the refrigerated compartment. The flow inside the tube is taken as one-dimensional and divided into three regions: superheated vapor region, two-phase liquid-vapor region and sub-cooled liquid region. The two-phase flow is analyzed according to the homogeneous model, that is, considering conditions of thermal and hydrodynamic equilibrium between the phases. It is also considered the pressure drop of the flow inside the tube. The aluminum tape and the outer coating plate are considered as fins with adiabatic ends. The equations of the refrigerant flow: mass conservation, momentum and energy conservation, are solved by numerical integration and the energy conservation equation along the aluminum tape is solved by the Finite Volume method. The set of algebraic equations, resulting from the discretization process of the differential equations, is solved iteratively by successive iterations, point-to-point along the condenser tube and the aluminum tape. The results obtained are compared with experimental data available in the ... (Complete abstract click electronic access below) / Mestre
4

Análise numérica de condensadores do tipo arame-sobre-tubo usados em refrigeradores domésticos /

Lima, Rafael Sene de. January 2008 (has links)
Orientador: André Luiz Seixlack / Banca: Emanuel Rocha Woiski / Banca: José Roberto Simões Moreira / Resumo: Neste trabalho apresenta-se um modelo numérico para a simulação do escoamento transiente de fluidos refrigerantes ao longo de condensadores do tipo arame-sobre-tubo, comumente usados em refrigeradores domésticos que empregam o ciclo de compressão de vapor. A análise envolve o escoamento do fluido refrigerante no interior do tubo e a transferência de calor por convecção natural e radiação entre a superfície externa do tubo, as aletas em forma de arames cilíndricos e o ar externo. No interior do tubo o escoamento é considerado unidimensional e dividido em uma região monofásica de vapor superaquecido, uma região bifásica líquido-vapor e outra em que o refrigerante encontra-se no estado de líquido subresfriado. A queda de pressão no interior do tubo é também considerada. Na região bifásica o escoamento é considerado homogêneo, ou seja, são consideradas condições de equilíbrio térmico e hidrodinâmico entre as fases. Inicialmente, condições de regime permanente serão assumidas e posteriormente será analisada a resposta dinâmica do condensador às variações das condições de operação do sistema. A simulação do escoamento ao longo do condensador é obtida a partir da solução numérica das equações de conservação da massa, da quantidade de movimento e de conservação de energia. Para a parede do condensador, a equação de conservação de energia é resolvida para determinar a sua distribuição de temperatura. O método de Volumes Finitos é usado na discretização das equações governantes. O modelo permite a determinação, nos regimes permanente e transiente, das distribuições de pressão, título, temperatura do refrigerante e temperatura do tubo ao longo do condensador, em função da geometria do condensador e das condições de operação. O modelo proposto é analisado e os resultados obtidos são discutidos e comparados... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This work presents a numerical model to simulate the unsteady refrigerant fluid flow along wire-on-tube condensers, commonly used in vapor compression cycle based domestic refrigerators. The model considers the refrigerant flow inside the tube and the heat transfer from the outer surfaces of the wires and tubes to the surrounding air by free convection and radiation. The refrigerant flow along the condenser is divided into a vapor superheated singlephase region, a two-phase liquid-vapor flow region and a subcooled liquid region. The refrigerant pressure drop is taking into account. The homogeneous model is employed for the two-phase flow region, i.e. the hydrodynamic and thermal equilibrium between the phases are considered. Initially the steady state condition is considered and later condenser unsteady behavior is analyzed. The mass conservation, momentum and energy conservation equations for the refrigerant flow are solved in order to evaluate the distributions of mass flux, pressure and temperature of the refrigerant fluid, respectively. Also, the energy conservation equation for the tube wall is solved to determine the wall temperature distribution. The system of differential equations is solved using the Finite Volume method. The model is analyzed and the obtained results are compared with data available in the open literature. / Mestre
5

Análise numérica de condensadores do tipo arame-sobre-tubo usados em refrigeradores domésticos

Lima, Rafael Sene de [UNESP] 27 February 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:39Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-02-27Bitstream added on 2014-06-13T18:10:04Z : No. of bitstreams: 1 lima_rs_me_ilha.pdf: 1489215 bytes, checksum: ed4f819bbee11e72c48fb349bb496fc5 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Neste trabalho apresenta-se um modelo numérico para a simulação do escoamento transiente de fluidos refrigerantes ao longo de condensadores do tipo arame-sobre-tubo, comumente usados em refrigeradores domésticos que empregam o ciclo de compressão de vapor. A análise envolve o escoamento do fluido refrigerante no interior do tubo e a transferência de calor por convecção natural e radiação entre a superfície externa do tubo, as aletas em forma de arames cilíndricos e o ar externo. No interior do tubo o escoamento é considerado unidimensional e dividido em uma região monofásica de vapor superaquecido, uma região bifásica líquido-vapor e outra em que o refrigerante encontra-se no estado de líquido subresfriado. A queda de pressão no interior do tubo é também considerada. Na região bifásica o escoamento é considerado homogêneo, ou seja, são consideradas condições de equilíbrio térmico e hidrodinâmico entre as fases. Inicialmente, condições de regime permanente serão assumidas e posteriormente será analisada a resposta dinâmica do condensador às variações das condições de operação do sistema. A simulação do escoamento ao longo do condensador é obtida a partir da solução numérica das equações de conservação da massa, da quantidade de movimento e de conservação de energia. Para a parede do condensador, a equação de conservação de energia é resolvida para determinar a sua distribuição de temperatura. O método de Volumes Finitos é usado na discretização das equações governantes. O modelo permite a determinação, nos regimes permanente e transiente, das distribuições de pressão, título, temperatura do refrigerante e temperatura do tubo ao longo do condensador, em função da geometria do condensador e das condições de operação. O modelo proposto é analisado e os resultados obtidos são discutidos e comparados... / This work presents a numerical model to simulate the unsteady refrigerant fluid flow along wire-on-tube condensers, commonly used in vapor compression cycle based domestic refrigerators. The model considers the refrigerant flow inside the tube and the heat transfer from the outer surfaces of the wires and tubes to the surrounding air by free convection and radiation. The refrigerant flow along the condenser is divided into a vapor superheated singlephase region, a two-phase liquid-vapor flow region and a subcooled liquid region. The refrigerant pressure drop is taking into account. The homogeneous model is employed for the two-phase flow region, i.e. the hydrodynamic and thermal equilibrium between the phases are considered. Initially the steady state condition is considered and later condenser unsteady behavior is analyzed. The mass conservation, momentum and energy conservation equations for the refrigerant flow are solved in order to evaluate the distributions of mass flux, pressure and temperature of the refrigerant fluid, respectively. Also, the energy conservation equation for the tube wall is solved to determine the wall temperature distribution. The system of differential equations is solved using the Finite Volume method. The model is analyzed and the obtained results are compared with data available in the open literature.
6

Análise do desempenho de condensadores de parade-aquecida usados em refrigeradores domésticos / Numerical analysis of hot-wall condensers for domestic refrigerators

Lima, Roniel de Souza [UNESP] 28 July 2017 (has links)
Submitted by Roniel de Souza Lima null (roniel.engmec@gmail.com) on 2017-09-13T17:06:48Z No. of bitstreams: 1 versão final_dissertação_Roniel Lima_17 setembro 2017.pdf: 4567933 bytes, checksum: 8c4bf48e57f6f60dabd2a29c4eb7026b (MD5) / Approved for entry into archive by Luiz Galeffi (luizgaleffi@gmail.com) on 2017-09-15T13:34:02Z (GMT) No. of bitstreams: 1 lima_rs_me_ilha.pdf: 4567933 bytes, checksum: 8c4bf48e57f6f60dabd2a29c4eb7026b (MD5) / Made available in DSpace on 2017-09-15T13:34:02Z (GMT). No. of bitstreams: 1 lima_rs_me_ilha.pdf: 4567933 bytes, checksum: 8c4bf48e57f6f60dabd2a29c4eb7026b (MD5) Previous issue date: 2017-07-28 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Neste trabalho apresenta-se um modelo distribuído para análise de condensadores do tipo parede aquecida, hot-wall, usados em refrigeradores domésticos. Nesse modelo considera-se o escoamento do fluido refrigerante no interior do tubo do condensador e a transferência de calor entre a placa de revestimento externo do refrigerador e o ar ambiente. No modelo, inclui-se também a transferência de calor ao longo da fita de alumínio, usada para fixação do tubo na placa de revestimento externo e a transferência de calor através do isolamento térmico para o interior do compartimento refrigerado. O escoamento no interior do tubo é considerado unidimensional e dividido em três regiões: região monofásica de vapor superaquecido, região bifásica líquido-vapor e região monofásica de líquido sub-resfriado. O escoamento bifásico é analisado segundo o modelo homogêneo, ou seja, considerando condições de equilíbrio térmico e hidrodinâmico entre as fases. Considera-se também a queda de pressão do escoamento no interior do tubo. A fita de alumínio e a placa de revestimento externo são consideradas como aletas com extremidades adiabáticas. As equações do escoamento do fluido refrigerante: conservação da massa, quantidade de movimento e conservação de energia, são resolvidas por integração numérica e a equação de conservação de energia ao longo da fita de alumínio é resolvida pelo método de Volumes Finitos. O sistema de equações algébricas, decorrente do processo de discretização das equações diferenciais, é solucionado iterativamente por substituições sucessivas, ponto a ponto, ao longo do tubo do condensador e da fita de alumínio. Os resultados obtidos são comparados com dados experimentais disponíveis na literatura. Considerando toda a faixa de vazão em massa do fluido refrigerante analisada, 2,52 – 4,32 kg/h, o desvio absoluto médio entre os resultados calculados e os dados experimentais de capacidade do condensador foi de 1,8 %. / This work presents a distributed model for the analysis of hot-wall condensers used in domestic refrigerators. In this model, the flow of refrigerant inside the condenser tube and the heat transfer between the outer coating plate of the refrigerator and the ambient air are considered. Also included in this model the heat transfer along the aluminum tape used to hold the tube to the outer coating plate and the heat transfer through the thermal insulation into the refrigerated compartment. The flow inside the tube is taken as one-dimensional and divided into three regions: superheated vapor region, two-phase liquid-vapor region and sub-cooled liquid region. The two-phase flow is analyzed according to the homogeneous model, that is, considering conditions of thermal and hydrodynamic equilibrium between the phases. It is also considered the pressure drop of the flow inside the tube. The aluminum tape and the outer coating plate are considered as fins with adiabatic ends. The equations of the refrigerant flow: mass conservation, momentum and energy conservation, are solved by numerical integration and the energy conservation equation along the aluminum tape is solved by the Finite Volume method. The set of algebraic equations, resulting from the discretization process of the differential equations, is solved iteratively by successive iterations, point-to-point along the condenser tube and the aluminum tape. The results obtained are compared with experimental data available in the literature. Considering whole range of refrigerant mass flow rate analyzed, 2.52 - 4.32 kg/h, the mean absolute deviation between the calculated results and the experimental condenser capacity data was 1.8%.
7

<b>Development of a high-performance domestic refrigerator/freezer with R600a utilizing advanced cycle architecture and vapor-injected reciprocating compressor</b>

Changkuan Liang (20299014) 19 December 2024 (has links)
<p dir="ltr">Domestic refrigerator/freezers account for 6% of all energy consumption around the globe and mainly rely on vapor compression cycles to operate. Researchers have investigated advanced cycle architectures, such as dual-loop cycles and ejector-enhanced cycles to improve their efficiencies. However, the energy saving potential of these advanced cycles often do not justify the additional costs. To further improve efficiency and reduce energy consumption, this work presents and assesses a two-stage vapor-injected cycle for domestic refrigerator/freezer applications. The proposed cycle directs the refrigerant exiting the medium temperature evaporator directly into the injection port of a vapor-injection compressor. The cycle establishes two separate evaporation temperatures to better match the cabinet temperatures of fresh food and freezer compartments. The reduced difference between each cabinet temperature and its evaporation temperature can reduce heat transfer irreversibilities and improve overall system efficiency. A bypass circuit cycle triple-evaporator domestic refrigerator freezer was used as the baseline cycle to investigate the performance improvement of the proposed cycle. A previously validated dynamic model of the baseline cycle was modified to consider a two-stage vapor-injected cycle. The simulation predicted a 12.9% energy consumption reduction with the proposed cycle when utilizing the baseline compressor efficiency for the vapor-injected compressor.</p><p dir="ltr">To evaluate additional performance improvements, a detailed mechanistic compressor model of the baseline variable-speed compressor was developed and validated with experimental data. Next, a vapor-injection line was added to the compressor model as an additional flow path to the compression chamber. The injection line is modeled as a tube connected to an opening on the cylinder wall, which is uncovered during the compression stroke. The injection tube is controlled by a fast-acting solenoid valve to separate injection and suction flow for the compressor. Parametric studies were carried out to assess the effects of injection timing and injection port diameter on power consumption and overall isentropic efficiency with respect to the baseline compressor. It was found that vapor injection in the reciprocating compressor can reduce the specific work required by more than 10%. Based on parametric studies, opening time of the fast-acting solenoid valve directly impacts the compressor efficiency and mass flow rate. There exists an optimal cylinder pressure associated with the opening of the solenoid valve that leads to maximum compressor efficiency.</p><p dir="ltr">The mechanistic compressor model was integrated into the two-stage system model using a reduced-order model to obtain more realistic and higher fidelity results. The reduced-order model considers the injection thermodynamic state and timing as well as evaporating and condensing temperatures from the system operation. Further, a control scheme based on the two-stage vapor-injected cycle’s available control variables was developed. The vapor-injected reciprocating compressor’s injection timing was varied in a parametric study to study its effect on two-stage system’s performance. As a results, 29.7% energy consumption reduction compared to the baseline cycle was achieved at injection timing of 4.95 radians.</p><p><br></p><p dir="ltr">To confirm the design and realistic performance of the designed vapor-injected reciprocating compressor, a prototype was designed and tested. A fast-acting solenoid and in-line check valve are connected and mounted directly on the cylinder wall to reduce dead volume during compression. The solenoid valve is controlled using the crank angle measurement from a Hall-effect sensor detecting a series of specifically placed magnets on the crankshaft. The prototype compressor was tested using a hot-gas-bypass compressor test stand under different suction, discharge and injection pressures. The experimental results show the prototype compressor’s specific work was reduced by up to 25% during vapor-injected operation compared to its single-stage operation with no injection. The results also showed the specific work reduction increased with an increase of injection pressure when condensing and suction pressures were fixed. The experiments also confirmed the compressor is able to separate the suction and injection flow, confirming it’s ability to be used in the two-stage cycle.</p>
8

Energy Efficiency Improvements in Household Refrigeration Cooling Systems

Björk, Erik January 2012 (has links)
This thesis is based on eight articles all related to the characteristics of the cooling system and plate evaporator of a household refrigerator. Through these articles, knowledge is provided that can be used to increase the operational efficiency in household refrigeration. Papers A, B and C focus on heat transfer and pressure drop in a commonly used free convection evaporator – the plate evaporator. Applicable correlations are suggested on how to estimate the air side heat transfer, the refrigerant side pressure drop and the refrigerant side heat transfer. Papers D, E and F hold a unique experimental study of the refrigerant charge distribution in the cooling system at transient and steady state conditions. From this cyclic losses are identified and estimated and ways to overcome them are suggested. In paper G the topic “charging and throttling” is investigated in an unparalleled experimental study based on more than 600 data points at different quantities of charge and expansions device capacities. It results in recommendations on how to optimize the capillary tube length and the quantity of refrigerant charge. Finally, Paper H holds a thermographic study of the overall cooling system operating at transient conditions. Overall, a potential to lower the energy use by as much as 25 % was identified in the refrigerator studied. About 10 % was found on the evaporator’s air side. 1-2 % was identified as losses related to the edge effect of the evaporator plate. About 8 % was estimated to be cyclic losses. About 5 % was found in cycle length optimization.  It is believed that most of these findings are of general interest for the whole field of household refrigeration even though the results come from one type of refrigerator. Suggestions of simple means to reduce the losses without increasing the unit price are provided within the thesis / <p>QC 20120411</p>
9

O refrigerador doméstico como instrumento motivador para o ensino de física térmica : uma proposta para o curso Técnico Integrado em Refrigeração e Climatização

Poglia, Rodrigo January 2013 (has links)
Neste trabalho, apresentamos uma proposta de ensino de Física Térmica contextualizada e integrada à formação técnica para alunos de nível médio do curso Técnico Integrado em Refrigeração e Climatização do Instituto Federal Sul-rio-grandense, Campus Venâncio Aires, RS. O trabalho foi desenvolvido com 60 alunos de duas turmas de primeiro ano, durante o segundo semestre de 2011 e, concretizou uma proposta de ementa que buscou construir um currículo integrado entre a formação geral e a técnica, com vistas a uma formação unitária e um ensino potencialmente significativo. Como instrumento motivador e desencadeador do processo de ensino/aprendizagem, utilizou-se um sistema de refrigeração doméstico montado sob a forma de uma bancada didática que, associado a um texto de apoio produzido sob o referencial das teorias da aprendizagem significativa de David Ausubel e da interação social de Lev Semyonovich Vygotsky, guiaram as atividades com os alunos. O produto educacional resultante deste trabalho de conclusão compreende um material didático impresso preparado para a aplicação desta metodologia com alunos, ficando disponível para os demais interessados em utilizar ou adaptar tal material para a sua realidade de ensino. / In this work one presents a proposal of Thermal Physics teaching contextualized and integrated to the technical formation, directed to students of high school from the Integrated Technical Course on Refrigeration and Air Conditioning (Curso Técnico Integrado em Refrigeração e Climatização) of Instituto Federal Sul-rio-grandense, Campus Venâncio Aires, RS. This work was developed with 60 students of two classes of the first year during the second semester of 2011 and it aimed at making true a draft proposal which tries to build an integrated grade, between the general and technical formation, aiming at an unitary formation and a potentially significant teaching. As a motivating and starting instrument of the teaching-learning process one used a domestic refrigeration system, mounted on a teaching table that, associated to a help text, produced based on the theories of significant learning of David Ausubel and the social interaction of Lev Semyonovich Vygotsky, guided the activities along with the students. The educational product resulting from this completion work comprehends a printed didactical material prepared to the application of this methodology with the students, being available to anyone who may be interested in using or adapt such material to their teaching reality.
10

O refrigerador doméstico como instrumento motivador para o ensino de física térmica : uma proposta para o curso Técnico Integrado em Refrigeração e Climatização

Poglia, Rodrigo January 2013 (has links)
Neste trabalho, apresentamos uma proposta de ensino de Física Térmica contextualizada e integrada à formação técnica para alunos de nível médio do curso Técnico Integrado em Refrigeração e Climatização do Instituto Federal Sul-rio-grandense, Campus Venâncio Aires, RS. O trabalho foi desenvolvido com 60 alunos de duas turmas de primeiro ano, durante o segundo semestre de 2011 e, concretizou uma proposta de ementa que buscou construir um currículo integrado entre a formação geral e a técnica, com vistas a uma formação unitária e um ensino potencialmente significativo. Como instrumento motivador e desencadeador do processo de ensino/aprendizagem, utilizou-se um sistema de refrigeração doméstico montado sob a forma de uma bancada didática que, associado a um texto de apoio produzido sob o referencial das teorias da aprendizagem significativa de David Ausubel e da interação social de Lev Semyonovich Vygotsky, guiaram as atividades com os alunos. O produto educacional resultante deste trabalho de conclusão compreende um material didático impresso preparado para a aplicação desta metodologia com alunos, ficando disponível para os demais interessados em utilizar ou adaptar tal material para a sua realidade de ensino. / In this work one presents a proposal of Thermal Physics teaching contextualized and integrated to the technical formation, directed to students of high school from the Integrated Technical Course on Refrigeration and Air Conditioning (Curso Técnico Integrado em Refrigeração e Climatização) of Instituto Federal Sul-rio-grandense, Campus Venâncio Aires, RS. This work was developed with 60 students of two classes of the first year during the second semester of 2011 and it aimed at making true a draft proposal which tries to build an integrated grade, between the general and technical formation, aiming at an unitary formation and a potentially significant teaching. As a motivating and starting instrument of the teaching-learning process one used a domestic refrigeration system, mounted on a teaching table that, associated to a help text, produced based on the theories of significant learning of David Ausubel and the social interaction of Lev Semyonovich Vygotsky, guided the activities along with the students. The educational product resulting from this completion work comprehends a printed didactical material prepared to the application of this methodology with the students, being available to anyone who may be interested in using or adapt such material to their teaching reality.

Page generated in 0.1078 seconds