• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 7
  • Tagged with
  • 8
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Cálculo de doses em radiocirurgias estereotáxicas com aceleradores lineares e feixes cônicos

Rosa, Tiago Brizolara da January 2006 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências Físicas e Matemáticas. Programa de Pós-Graduação em Física. / Made available in DSpace on 2012-10-22T20:27:25Z (GMT). No. of bitstreams: 1 246997.pdf: 21549442 bytes, checksum: 5308e8a08fc0e009bcb53bf68006652e (MD5) / Este trabalho descreve os conceitos e métodos utilizados no desenvolvimento do módulo de física de um sistema de planejamento de radiocirurgias estereotáxicas de cabeça utilizando colimadores cônicos adaptados a aceleradores lineares. A determinação das doses fundamenta-se em dois conjuntos básicos de informação: (a) os padrões de deposição de dose de cada cone, obtidos através de dosimetria do feixe com detectores posicionados em locais selecionados em um simulador de água ou material dosimetricamente equivalente e (b) geometria detalhada e precisa do paciente, obtida através da construção de um modelo anatômico tridimensional a partir de estudos tomográficos realizados com um sistema de referência estereotáxico fixado à cabeça do paciente. O módulo de física implementa métodos para construção de mapas de dose a partir da informação dosimétrica, detecção do contorno da cabeça do paciente, integração da dose depositada por arcos radiocirúrgicos definidos pelo movimento da mesa e do cabeçote do acelerador, visualização das curvas de isodose sobre cortes tomográficos, cálculo e visualização de histogramas dose-volume e emissão de relatório com os parâmetros de irradiação para cada arco (incluindo as unidades de monitor calculadas). Planejamentos realizados com o sistema desenvolvido foram comparados a planejamentos obtidos com um sistema em uso clínico há vários anos, com resultados praticamente idênticos. O trabalho apresenta ainda uma introdução sobre radiocirurgias estereotáxicas e um apêndice com conceitos básicos de interação da radiação com a matéria, numa tentativa de contribuir para o preenchimento da lacuna existente no que se refere a textos em português sobre o tema.
2

Desenvolvimento de um dosímetro in vivo a MOSFET para aplicações em radioterapia

Siebel, Osmar Franca January 2013 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Elétrica, Florianópolis, 2013. / Made available in DSpace on 2014-08-06T17:21:47Z (GMT). No. of bitstreams: 1 325426.pdf: 6454074 bytes, checksum: 53e8bea408ce70608702b736942b96c2 (MD5) Previous issue date: 2013 / Na radioterapia (teleterapia), a diferença entre a dose prescrita e a dose recebida pelo paciente deve ser de no máximo 5%. Por esta razão o uso de dosímetros é essencial para atingir esta especificação e garantir o sucesso deste tipo de tratamento contra o câncer. Neste trabalho é apresentado um dosímetro in vivo a MOSFET para aplicações radioterápicas que possui um processo de leitura simples e preciso e que utiliza um sensor pequeno e de baixo custo. Além disso, este dosímetro não requer cabos ou baterias durante a irradiação o que é vantajoso, pois os metais presentes nestes componentes interagem com a radiação podendo assim alterar o valor da dose recebida pelo paciente. No dosímetro desenvolvido foi utilizado o circuito integrado (CI) CD4007UBM (Texas Instruments) como sensor de radiação. A sua escolha é justificada, pois seus transistores MOS possuem um óxido de porta com espessura de 120nm. Esta espessura é indicada para a aplicação desejada, pois tem uma sensibilidade à radiação ionizante próxima de 7 mV/Gy e permite a operação com tensões relativamente baixas, |VT| 1,6 V. Além disso, este CI é de muito baixo custo (R$1/CI) e possui dimensões reduzidas (área de 35mm2 e espessura inferior a 2 mm). Em um dosímetro a MOSFET a dose total é inferida pela variação da tensão de limiar (VT) devido à radiação ionizante, deste modo o circuito extrator de VT é um bloco fundamental deste tipo de dosímetro. No dosímetro desenvolvido foi utilizado um circuito extrator com corrente constante (CC) preciso, com baixo consumo e que determina diretamente o valor de VT. É importante mencionar que este extrator CC opera na inversão moderada (enquanto extratores CC convencionais são polarizados na inversão forte) e extrai um valor de VT que possui significado físico. Os experimentos com radiação ionizante foram realizados no Centro de Pesquisas Oncológicas (CEPON) em Florianópolis utilizando aceleradores lineares para gerar raios-X de 6 MV e 15 MV. Dentre os principais resultados do protótipo do dosímetro MOSFET CD4007 podemos citar: sensibilidade de 98,1 mV/Gy, dependência térmica de 0,5 cGy/°C, dependência angular de 13%, dependência energética de 1,3%, linearidade de 97,5% e atenuação ao feixe de apenas 0,14%.<br> / Abstract : In radiotherapy (teletherapy), the maximum difference between the prescribed dose and the dose delivered to the patient must be ±5%. For this reason, the use of dosimeters is essential to meet this specification and, consequently, to ensure the success of this type of cancer treatment. In this work we present a new in vivo MOSFET dosimeter suitable for in vivo radiotherapy applications which combines a simple and accurate readout procedure with a small size, low-cost, and cable/battery-free sensor. The absence of cable and battery during irradiation is interesting because metals that are present in these components can deflect radiation and, consequently, change the dose received by the patient. The dosimeter that we developed uses the integrated circuit (IC) CD4007UBM (Texas Instruments) as the radiation sensor. This IC was chosen because its MOS transistors have a gate oxide thickness of 120 nm, which is indicated for the desired application since it has adequate radiation sensitivity (7 mV/Gy) and is able to operate at relatively low voltage (|VT | ~= 1,6 V). Moreover, this IC has a very low cost, US$0.5/IC, and small dimensions (35 mm2 and thickness lower than 2 mm). MOSFET dosimeters sense the total dose by the variation of the threshold voltage (VT ) due to ionizing radiation; for this reason, the VT -extractor circuit is a fundamental block in this type of dosimeter. In our dosimeter we used an accurate and lowpower constant-current (CC) VT -extractor circuit that directly determines the VT . It is worth to mention that this CC extractor operates in moderate inversion (conventional CC extractors are biased in strong inversion) and extracts a value of VT that has physical meaning. Experiments with ionizing radiation were carried out at the Centro de Pesquisas Oncol´ogicas (CEPON) in Florian´opolis/Santa Catarina using linear accelerators to generate X rays of 6 MV and 15 MV. Among the main results of the CD4007 MOSFET dosimeter we can highlight: radiation sensitivity 98.1 mV/Gy, thermal dependence 0.5 cGy/?C, angular dependence of 13%, energy dependence of 1.3%, linearity of 97.5%, and attenuation to the radiation beam of 0.14%.
3

Verificação das condições de uso e funcionamento dos aparelhos de raios X odontológicos, na cidade de Itajaí, Santa Catarina

Mezadri, Ariel César 12 May 2000 (has links)
Orientador: Frab Norberto Bóscolo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-17T06:54:43Z (GMT). No. of bitstreams: 1 Mezadri_ArielCesar_M.pdf: 13427930 bytes, checksum: 64f72909457587aefddb45598e8b7d12 (MD5) Previous issue date: 2000 / Resumo: Este foi um estudo realizado sobre as condições de uso e funcionamento em 70 aparelhos de raios X odontológicos, na cidade de Itajaí, Santa Catarina, com o objetivo de verificar se os profissionais estavam trabalhando dentro das normas preconizadas para o uso, e se os aparelhos estavam funcionando dentro dos padrões aceitáveis, fundamentado na Portaria n° 453, de 10 de junho de 1998, da Secretaria de Vigilância Sanitária do Ministério da Saúde. Foram analisados: tensão nominal da rede elétrica, reprodutibilidade e exatidão do tempo de exposição, tensão de pico, reprodutibilidade da taxa de Kerma no ar, linearidade da taxa de Kerma com o tempo de exposição, diâmetro e alinhamento de campo de radiação, determinação do tempo de exposição com escala de densidade, tipo e comprimento do localizador e padrão de imagem radiográfica. Os resultados obtidos indicaram que a quilovoltagem efetiva, no geral, foi menor que a nominal. Um percentual de 45,7% dos aparelhos precisavam correção imediata do tamanho de campo do feixe útil de radiação e 47,1% de alinhamento. Cerca de 14,3% dos pesquisados estavam utilizando localizadores do tipo cônico fechado. Dos profissionais, 78,6% não estavam seguindo corretamente as regras que norteiam o processamento de filmes fotográficos. Finalmente, conclui-se que os aparelhos de raios X avaliados não estavam trabalhando adequadamente dentro das normas peconizadas para seu uso. / Abstract: This work was a study accomplished on the use conditions and operation in 70 apparels of odontological X rays, in the city of Itajaí, Santa Catarina, with the objective of verifying if the professionals were using the recommended norms of handling and if the apparels were working inside of the acceptable patterns, being based in the judicial directive no. 453, of June 1, 1998, of the Clerkship of Sanitary Surveillance of the Ministry of the Health. They were analyzed: nominal tension of the electric net, reprodutability of the rate of Kerma in the air, linearity of the rate of Kerma with the time of exhibition, diameter and alignment of radiation field, determination of the time of exhibition with density scale, type and length of the finder and pattern of radiography image. The obtained results indicated that the effective quilovolt, in general, was smaller than to nominal. A percentile of 45,7% of the apparels needed immediate correction of the size of field of the useful bunch of radiation and 47,1% of alignment. About 14,30/0 of those researched were using finders of the shut conical type. Among professionals, 78,60/0 were not following correctly the rules of processing radiography. Finally, it was concluded that the apparels of X rays were not working according to the acceptable patterns, and the professional were not working appropriately inside the norms for X ray's use. / Mestrado / Mestre em Radiologia Odontológica
4

Estrutura eletrônica do polímero orgânico conjugado MEH-PPV em solução sob radiação ionizante

Batagin Neto, Augusto [UNESP] 17 February 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:30Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-02-17Bitstream added on 2014-06-13T18:50:42Z : No. of bitstreams: 1 bataginneto_a_me_bauru.pdf: 728792 bytes, checksum: 1630464fa8b5bc3088ecee698a2e6b9e (MD5) / Os polímeros orgânicos conjugados têm sido amplamente utilizados em diversos campos tecnológicos devido às suas características semicondutoras e ópticas. Recentemente foi relatada a possibilidade de sua utilização na área de dosimetria. O polímero MEH-PPV, quando diluído em solventes que contenham halogênios, tem apresentado características bastante promissoras nesta área, contudo não há ainda uma completa compreensão dos mecanismos envolvidos. No presente trabalho realizou-se o estudo conformacional e da estrutura eletrônica do polímero MEH-PPV em clorofórmio e as possíveis alterações provenientes da irradiação desta solução com radiações ionizantes. Métodos de modelagem de materiais foram utilizados a fim de simular o sistema. Resultados experimentais sugerem que os efeitos observados são oriundos da interação do solvente com a cadeia polimérica. A fim de investigar tal possibilidade, uma análise dos prováveis sítios de maior reatividade sobre o polímero foi realizada, apontando um mecanismo de incorporação de radicais sobre a cadeia principal. / Organic conducting polymers have been employed in several technological fields due to its semiconducting and optical properties. Recently, several reports points to applications in radiation dosimetry. When diluted in halogen-containing solvents, the polymer MEH-PPV shows interesting properties after gamma irradiation. Despite the promising application, still is lacking a complete understanding of the underlying phenomena. In the present work, we studied the geometry conformation and electronic structure of MEH-PPV in the presence of chloroform employing molecular modeling techniques to simulate the system. Several possibilities for polymer modification under gamma radiation were investigated, following suggestion from experimental results. Finally, a model for the color modifications of the solution is present.
5

Estudo de desempenho de dosimétros eletrônicos em feixes de raios X contínuos e pulsados

Margarete Cristina Guimarães 27 February 2014 (has links)
A monitoração individual é um procedimento básico de verificação da obediência às diretrizes regulatórias de proteção radiológica. Dosímetros eletrônicos com detectores de estado sólido (DE) têm sido amplamente usados para dosimetria pessoal, inclusive em feixes pulsados de radiação onde a resposta deles ainda não é conhecida e falhas têm sido registradas. Neste trabalho, condições de radiação para testar a resposta de DE em feixes contínuos e pulsados foram estudadas na máquina de raios X de potencial constante Seifert-Pantak HS320 e na máquina de raios X médico VMI Pulsas 800 Plus. Os feixes foram caracterizados em termos de tensão no tubo, camada semirredutora, energia média e taxa de kerma no ar. A coerência metrológica do detector Xi R/F Unfors usado como referência nas medidas de kerma no ar foi verificada contra câmaras de ionização Radcal 10X6-6 a RC-6. Dosímetros eletrônicos RADOS Rad-60, Aloka PDM-111 Thermoelectron e EPD MK2 foram testados quanto ao erro intrínseco relativo e dependência energética em radiações similares às qualidades RQR e RQA da IEC e série N da ISO. Os resultados demonstraram a confiabilidade do dosímetro de estado sólido Unfors Xi R/F, embora sua resposta mostrasse ser afetada em feixes altamente filtrados. Os testes nos DE mostraram que alguns erros intrínsecos relativos em termos de equivalente de dose pessoal, Hp(10), foram maiores que os valores estabelecidos em normas para feixes contínuos. Em feixes pulsados, alguns DE não responderam adequadamente à radiação e apresentaram erros intrínsecos relativos bem altos. Este trabalho ressaltou a necessidade de testes adicionais nos DE, além de limitada calibração em feixes de 137Cs, antes de usá-los em feixes pulsados de raios X. / Personal radiation monitoring is a basic procedure to verify the compliance to regulatory requirements for radiological protection. Electronic personal dosimeters (EPD) based on solid state detectors have largely been used for personnel monitoring; including for pulsed radiation beams where their responses are not well known and deficiencies have been reported. In this work, irradiation conditions for testing the response of EPDs in both continuous and pulsed X-ray beams were studied to be established in a constant potential Seifert-Pantak and in a medical Pulsar 800 Plus VMI X-ray machines. Characterization of X-ray beams was done in terms of tube voltage, half-value layer, mean energy and air kerma rate. A Xi R/F Unfors solid state dosimeter used as reference for air kerma measurements was verified against a RC-6 and 10X6-6 Radcal ionization chambers as far its metrological coherence. Rad-60 RADOS, PDM- 11 Aloka and EPD MK2 Thermoelectron EPDs were selected to be tested in terms of relative intrinsic error and energy response in similar to IEC RQR, IEC RQA and ISO N reference radiations. Results demonstrated the reliability of the solid state Xi R/F Unfors dosimeter to be as reference dosimeter although its response was affected by heavily filtered beams. Results also showed that relative intrinsic errors in the response of the EPDs in terms of personal dose equivalent, Hp(10), were higher than the requirement established for continuous beams. In pulsed beams, some EPDs showed inadequate response and high relative intrinsic errors. This work stressed the need of performing additional checks for EPDs, besides the limited 137Cs beam calibration, before using them in pulsed X-ray beams.
6

Desenvolvimento e caracterização de dosímetros para monitoração individual de trabalhadores ocupacionalmente expostos à radiação combinando as técnicas de termoluminescência (TL) e luminescência opticamente estimulada (OSL) / Development and characterization of dosimeters for individual monitoring of workers occupationally exposed to radiation combining the techniques of thermoluminescence (TL) and optically stimulated luminescence (OSL)

Malthez, Anna Luiza Metidieri Cruz, 1985- 28 August 2018 (has links)
Orientadores: Vera Lúcia da Silveira Nantes Button, Marcelo Baptista de Freitas / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-28T09:42:26Z (GMT). No. of bitstreams: 1 Malthez_AnnaLuizaMetidieriCruz_D.pdf: 4070699 bytes, checksum: 5b502eb8b2975aac6052df7ad659d32a (MD5) Previous issue date: 2015 / Resumo: Neste estudo foi desenvolvido um dosímetro (monitor individual) para monitoração externa de indivíduos ocupacionalmente expostos à radiação (raios X e gama) que faz o uso simultâneo das técnicas de termoluminescência (TL) e luminescência opticamente estimulada (OSL - Optically Stimulated Luminescence), combinado às diferentes características dosimétricas de detectores já utilizados com a técnica TL na rotina dos Serviços de Monitoração Individual Externa (SMIEs) no Brasil (LiF:Mg,Ti ¿ TLD100, CaF2:natural, CaSO4:Dy - IPEN) e detectores utilizados com a técnica OSL, ainda pouco explorados na monitoração individual (BeO ¿ Thermalox 995) e recentemente autorizados a serem utilizados com a técnica OSL no país (Al2O3:C - Luxel). Para o desenvolvimento do monitor, diversas características intrínsecas e dosimétricas dos detectores empregando as técnicas TL e OSL em três diferentes equipamentos leitores foram avaliadas. Testes de desempenho foram aplicados ao monitor desenvolvido, conforme critérios estabelecidos no país e no exterior (CASEC e IEC, respectivamente). Os resultados obtidos demonstram que as respostas TL e OSL dos detectores dependem fortemente da configuração do leitor utilizado, da técnica empregada (TL ou OSL) e do tipo de sinal avaliado, no caso da técnica OSL (OSL total ou inicial). Assim é fundamental uma análise prévia de características intrínsecas do material, como comprimento de onda principal da emissão luminescente, tipo (inicial ou total) e magnitude (doses baixa, moderada ou alta) do sinal que será avaliado para a escolha adequada dos parâmetros do leitor (filtros, máscaras, potência, entre outros) empregando as duas técnicas. Os resultados obtidos com a técnica OSL reforçam seu uso na monitoração individual no Brasil, uma vez que estavam em acordo com a técnica TL, amplamente empregada pelos SMIEs nacionais. Além da determinação de dose individual, normalmente empregada na monitoração de trabalhadores, o dosímetro desenvolvido permite também estimar doses acumuladas ao longo do tempo, empregando a técnica OSL nos detectores de Al2O3:C ou BeO, sendo que no caso deste último, a dose única (ou individual) também pode ser determinada com a técnica TL aplicada simultaneamente no mesmo detector. Após a avaliação das respostas em energia dos detectores, um algoritmo foi desenvolvido, testado e validado para avaliar fatores de correção com respeito à energia, baseado na razão entre as respostas de um par de detectores TL e OSL. Os resultados demonstraram que as diferentes razões entre os sinais provenientes do par, permitem avaliar de forma precisa a qualidade da radiação à qual o par de detectores foi exposto. O monitor desenvolvido possui três configurações diferentes de pares de detectores, Al2O3:C/LiF:Mg,Ti, Al2O3:C/BeO e CaSO4:Dy/BeO. Ele apresenta como principais vantagens, em relação aos dosímetros já existentes em uso comercialmente, a possibilidade de poder inferir informações sobre a dose e qualidade da radiação (energia efetiva) sem a utilização de filtros e com diminuição das incertezas associadas, avaliar doses acumuladas ao longo do tempo com o mesmo dosímetro e combinar todas as características dos detectores associadas às técnicas TL e OSL, simultaneamente em um mesmo dosímetro. Os resultados dos testes de desempenho do monitor apresentaram conformidade com os critérios nacionais e internacionais estabelecidos, e contribuíram para que os critérios nacionais utilizados para a técnica TL possam ser estendidos para a técnica OSL / Abstract: In this study a dosimeter (personal monitor) for external monitoring of individuals occupationally exposed to radiation (X and gamma rays) was developed using simultaneously thermoluminescent (TL) and optically stimulated luminescence (OSL) techniques. Intrinsic characteristics of detectors already used with TL technique in External Individual Monitoring Services routine in Brazil (LiF:Mg,Ti ¿ TLD 100, CaF2:natural and CaSO4:Dy ¿ IPEN) were combined to detectors used with OSL technique, one less explored (BeO ¿ Thermalox 995), and other recently approved (Al2O3:C - Luxel) to be used in individual monitoring in the country (Al2O3:C - Luxel). During the monitor development, several intrinsic and dosimetric characteristics of detectors were evaluated employing TL and OSL techniques in three different reader equipments. Performance tests were applied to the developed monitor according to national and international established criteria (CASEC and IEC, respectively). The obtained results showed that the responses of TL and OSL detectors are strongly dependent on reader configuration, employed technique (TL and OSL) and, in the particular case of OSL technique, also the signal (total or initial OSL). Therefore, a previous analysis of the intrinsic characteristics of the material, as the main wavelength of the luminescent emission, the signal type (initial or total) and dose magnitude (low, moderate or high) must to be made in order to select the reader configuration (filters, power, and others) used with each technique. The results obtained with OSL technique reinforce its use in Brazil, as they were in agreement with TL technique, which is already largely used by national EIMS. In addition to the assess of individual dose, usually employed in workers monitoring, the developed dosimeter allows evaluating accumulated dose over time using OSL technique with Al2O3:C or BeO detectors, and single or individual doses can be evaluated applying TL technique simultaneously applied in the same detector. After the evaluation of the energy response of detectors, an algorithm was developed, tested and validated to assess correction factors with respect to energy, based on the ratio of the responses of a pair of TL and OSL detectors. The results confirm that the different ratios between signals from a detector pair allow to evaluate more accurately the radiation quality to that the pair of detectors were exposed. The monitor was developed with three different arrangements of pairs of detectors, Al2O3:C/LiF:Mg,Ti, Al2O3:C/BeO and CaSO4:Dy/BeO. It presents as main advantages, compared to existing commercial dosimeters in use, the possibility to infer information on the dosage and quality of radiation (effective energy) without the use of filters and reducing associated uncertainties, to assess cumulative doses over time with the same dosimeter, and to combine all features of the detectors associated with TL and OSL techniques, simultaneously, in the same dosimeter. The results of the performance tests of the developed monitor were in accordance to national and international criteria, and contributed to that the national criteria, used for TL technique, can also be extended to the OSL technique / Doutorado / Engenharia Biomedica / Doutora em Engenharia Elétrica
7

Implantação de radiações de referência em máquina de raios X diagnóstico médico para fins de calibração de dosímetros pessoais

Annibal Theotonio Baptista Neto 28 February 2005 (has links)
Nenhuma / Campos de raios-x que estejam em conformidade com os requisitos internacionais de padronização nem sempre são disponíveis em uma região e, principalmente, em países em desenvolvimento. Esta situação tem sido usada como justificativa para a ausência de calibração de dosímetros pessoais e tem contribuído para a falta de confiabilidade nos programas de monitoração de trabalhadores expostos à radiação. Considerando a existência de diversas máquinas de raios-x em hospitais e a necessidade da calibração de dosímetros pessoais, este trabalho investigou a viabilidade da implantação de feixes de radiação-x destinados à calibração, comparáveis às radiações padronizadas internacionalmente, em uma máquina de raios-x diagnóstico médico. A implantação das radiações para calibração foi realizada com a determinação e comparação de parâmetros dos feixes de raios-x como a tensão do tubo, camada semi-redutora, uniformidade do campo de radiação, filtração e radiação espalhada. Os procedimentos, a geometria e as condições de irradiação foram, sempre, os mais simples possíveis para uma confiabilidade mínima dos resultados, nas condições usuais em hospitais. A viabilidade do uso dos feixes de radiação implantados foi confirmado através da análise do desempenho de um dosímetro pessoal do tipo filme, em calibrações e irradiações no Laboratório de Calibração de Dosímetros do Centro de Desenvolvimento da Tecnologia Nuclear, no Laboratório Nacional de Metrologia das Radiações Ionizantes e no University of Wisconsin Radiation Calibration Laboratory. Apesar da diferença entre os feixes de raios-x implantados e as radiações de referência, o desempenho do dosímetro pessoal atendeu aos requisitos para a monitoração individual. / X-ray fields that comply with international standardization requirements are not available in a world region, mainly in developing countries. This is used as an excuse for a lack of calibration of personal dosimeters and, consequently, a lack of reliability in individual monitoring programs applied to occupational workers under radiation exposures. Considering the availability of x-ray machines in many hospitals, this work studied the feasibility of implementing x-ray calibration beams in a medical diagnostic machine, which are comparable to international reference radiations for calibrating personal dosimeters. Implementation of the calibration beams was carried out by determining and comparing beam parameters as tube voltage, half-value layer, beam uniformity, filtration and scattered radiation. Procedures, geometry and exposure conditions were as simple as possible for a minimum reliability and close to the hospital conditions. The feasibility of the use of the implemented radiation beams was confirmed by analyzing the performance of a film personal dosimeter under calibration and irradiation at the Dosimeter Calibration Laboratory of the Centro de Desenvolvimento da Tecnologia Nuclear, the National Metrology Laboratory for Ionizing Radiations and the University of Wisconsin Radiation Calibration Laboratory. In spite of the difference between the implemented x-ray beams and the reference radiations, the performance of the film personal dosimeter complied with the accuracy requirements for individual monitoring.
8

Avaliação da exposição ocupacional do cristalino em radiologia intervencionista

Flavia Luiza Soares Borges 26 August 2013 (has links)
Estudos recentes têm indicado o aumento da incidência de opacidade do cristalino para baixas doses de radiação. Considerando os dados epidemiológicos, a Comissão Internacional de Proteção Radiológica (ICRP) emitiu um comunicado que mudou o limite de dose absorvida para o cristalino. A publicação também recomenda a redução dos limites de dose equivalente para os indivíduos ocupacionalmente expostos, agora considerado de 20 mSv em um ano, em média, ao longo de cinco anos. Como consequência, algumas exposições planejadas requerem o uso de dosímetro adicional para estimar a dose no cristalino em profissionais. Este é o caso dos profissionais de radiologia intervencionista. Atualmente, as normas nacionais e internacionais, carecem de uma metodologia específica para a dosimetria em Hp(3). A recomendação ICRP provocou o debate sobre a adequação da grandeza equivalente de dose e sobre os métodos para as suas medições. Os objetivos deste trabalho foram: estudar a metodologia para a calibração de dosímetros pessoais em Hp(3) e monitorar profissionais durante os procedimentos de radiologia intervencionista. Diretrizes internacionais e recomendações da literatura recente foram adotadas para os procedimentos de calibração e testes. Para calibração, o sistema de dosimetria, que consiste em um suporte e um detector termoluminescente LiF:Mg,Cu,P (TLD-100H), foi exposto a radiações de referência em um fantoma cilíndrico preenchido com água, que se simulou a cabeça. Os fatores de calibração foram determinados para o potencial de tubo 20-150 kV da série 4037 estreito espectro de ISO. A monitoração individual foi realizada durante procedimentos vasculares de angioplastia e angiografia. Os resultados mostraram-se satisfatórios comparados à literatura. / Recent studies have indicated the increase of the incidence of lens opacities for low radiation doses. Considering epidemiological data, the International Commission on Radiological Protection (ICRP) issued a statement that changed the absorbed dose threshold for the eye lens. The statement also recommends a reduction in the dose limits to the eye lens for occupationally exposed persons; now it is considered to be 20 mSv in a year averaged over five years. As consequence, some planned exposures require the use of additional dosemeter for estimating eye lens dose in professionals; it is the case of the staff in interventional radiology. Nowadays, in the national and international standards there is a lack of specific methodology for eye lens dosimetry. The ICRP recommendation raised the debate on the adequacy of dose equivalent quantities of radiological protection and on the methods for their measurements. The objectives of this research were to study the methodology for calibrating personal dosemeters in Hp (3) and monitor professionals during interventional radiology procedures. International guidelines and recent literature were adopted for the calibration procedures and tests. For calibration, the dosimetric system, consisting of a holder and thermoluminescent detector LiF:Mg,Cu,P (TLD-100H), was exposed to standard radiation fields on a cylindrical water phantom that simulated the head. The calibration coefficients of the dosimetric system were determined for tube potential from 20 to150 kV of the ISO 4037 narrow spectrum series. The individual monitoring was performed during vascular procedures - angiography and angioplasty. The results were satisfactory were compared to the literature

Page generated in 0.0367 seconds