• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 69
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 75
  • 75
  • 75
  • 55
  • 28
  • 27
  • 26
  • 22
  • 18
  • 18
  • 14
  • 14
  • 14
  • 12
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Metodologia de projeto cooperativo para condicionadores de qualidade de energia

Liberado, Eduardo Verri [UNESP] 02 March 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:22:34Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-03-02Bitstream added on 2014-06-13T19:28:07Z : No. of bitstreams: 1 liberado_ev_me_bauru.pdf: 1524353 bytes, checksum: 5a5ec88c9ac35fcba41e0a65ff12ce49 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / As discussões recentes na área de condicionamento de energia elétrica têm como objetivo integrar as tecnologias de compensação convencionais às tendências do setor elétrico, às quais apontam para a distribuição da geração e do condicionamento de energia ao longo da rede, contribuindo para a configuração da chamada rede inteligente. Visando contribuir com tais discussões este trabalho apresenta o desenvolvimento de uma metodologia de projeto e controle de sistemas de condicionamento de energia, nos quais diversas tecnologias de compensadores sejam capazes de operar cooperativamente. As definições matemáticas desta metodologia são embasadas na teoria de potência conservativa, uma modelagem matemática recente que associa características de circuitos elétricos à parcelas de corrente e potência. As tecnologias de compensadores utilizadas são os compensadores estáticos de reativos, filtros passivos e filtros ativos. Os compensadores projetados e controlados de acordo com a metodologia proposa foram testadas em simulação para atuar em redes com alta e baixa impedância de linha, na presença de cargas lineares e não lineares e em configurações fixas e variáveis ao longo do tempo de simulação. Em todos os casos, a compensação atenuou significativamente distúrbios de corrente relacionados com reativos, desequilíbrio e não linearidades entre tensões e correntes da carga. Uma rede com cargas distribuídas também foi simulada para avaliar a cooperação entre os compensadores, quando estavam conectados em diferentes pontos desta rede, bem como para discutir os possíveis critérios de projeto e controle da compensação distribuída / Recent discussions in power conditioning aim to integrate traditional compensation technologies to new trends in electrical system, which has been pointing to the characterization of the smart grid concept. In order to contribute to those discussions, this dissertation presents a methodology to design and control different technologies of power conditioners for cooperative compensation. The mathematical definitions used in the methodology came from conservative power theory, a recent mathematical modeling that offers power and current decompositions associated to some characteristics of electrical circuits. Thus, static var compensators, passive filters and active filters were designed according to the proposed methodology and tested in simulation with three-phase linear and loads connected to two typical grids, with and low line impedances. Results show effective compensation of reactive current, load unbalance and non linearities between voltage and current. Moreover, preliminary studies in distributed compensation are presented too, with simulations of a 13-node distribution grid based on IEEE 13-node test feeder, and the results of these simulations offer relevant considerations to extend the methodology to distributed compensators
42

Metodologia de projeto de controladores de amortecimento para posicionamento parcial de polos de modelos multimáquinas de sistemas de potência

Rossi, Carlos Henrique 10 August 2012 (has links)
Este trabalho propõe uma metodologia de projeto de controladores para o amortecimento de oscilações eletromecânicas de baixa frequência em sistemas elétricos de potência. O problema de controle é estruturado na forma de desigualdades matriciais, as quais permitem a busca por uma solução numérica para o problema de controle. Os controladores de amortecimento baseados na realimentação dinâmica de saída, gerados por metodologias de projeto na forma de desigualdades matriciais, geralmente apresentam ordem elevada. Além disso, projetos considerando sistemas de potência de médio porte demandam elevado tempo computacional. Nesse contexto, o presente trabalho propõe uma metodologia de projeto capaz de gerar controladores de ordem reduzida. A metodologia proposta adota um índice de desempenho que possibilita a redução do tempo computacional demandado no projeto. O índice de desempenho adotado para o sistema em malha fechada é a energia do sinal de saída do sistema. Essa energia corresponde à integral do valor quadrático do sinal adotado como saída do sistema. A metodologia proposta permite especificar um índice de desempenho apenas para aos modos de resposta de interesse do sistema, contornando as limitações das metodologias baseadas em posicionamento regional de polos. A relação entre o valor da energia do sinal de saída do sistema e seu fator de amortecimento é estabelecida por meio de uma equação algébrica. Neste trabalho, a metodologia é aplicada na geração de controladores de amortecimento para geradores síncronos. Entretanto, o procedimento proposto é genérico o suficiente para ser aplicado a outros tipos de geradores (gerador de indução empregado em unidades eólicas, por exemplo), a dispositivos FACTS (do Inglês, Flexible AC Transmission System) assim como a outros tipos de sistemas dinâmicos. A metodologia gerou um controlador eficaz para um caso onde a formulação baseada no tradicional posicionamento regional de polos é incapaz de gerar um controlador que assegure uma boa margem de estabilidade para o modo de resposta de interesse. / This work proposes a methodology for the design of controller to damp low frequency electromechanical oscillations in power systems. The control problem is structured in the form of matrix inequalities, which allows obtaining a numerical solution for the control problem. The damping controllers based on dynamic output feedback, generated by design methodologies in the form of matrix inequalities, usually presents high order. In addition, the design of this controller, considering large power systems, usually requires excessive computational effort. In this context, this work proposes a methodology for the design of reduced order controllers. The proposed methodology employs a performance index that is less costly in terms of computational effort when compared to the one with the traditional regional pole placement. The adopted performance index for the closed loop system is the energy of the system output. This energy corresponds to the integral of the signal squared regarding the system output. The proposed methodology allows specifying a performance index only for the response modes of interest, overcoming the limitations of the methodologies based on regional pole placement. The relation between the energy value of the output signal of the system and its damping factor is established by means of an algebraic equation. In this paper, the methodology is applied to generate damping controller for synchronous generators. However, the proposed procedure is general enough to be applied to other kinds of power plants (wind generation, for example), to FACTS devices, as well as to other dynamic systems. The methodology has generated an effective controller for a case where the formulation based on the regional pole placement is unable to generate a controller which assures a good stability margin for the response mode of interest.
43

Metodologia de projeto de controladores de amortecimento para posicionamento parcial de polos de modelos multimáquinas de sistemas de potência

Rossi, Carlos Henrique 10 August 2012 (has links)
Este trabalho propõe uma metodologia de projeto de controladores para o amortecimento de oscilações eletromecânicas de baixa frequência em sistemas elétricos de potência. O problema de controle é estruturado na forma de desigualdades matriciais, as quais permitem a busca por uma solução numérica para o problema de controle. Os controladores de amortecimento baseados na realimentação dinâmica de saída, gerados por metodologias de projeto na forma de desigualdades matriciais, geralmente apresentam ordem elevada. Além disso, projetos considerando sistemas de potência de médio porte demandam elevado tempo computacional. Nesse contexto, o presente trabalho propõe uma metodologia de projeto capaz de gerar controladores de ordem reduzida. A metodologia proposta adota um índice de desempenho que possibilita a redução do tempo computacional demandado no projeto. O índice de desempenho adotado para o sistema em malha fechada é a energia do sinal de saída do sistema. Essa energia corresponde à integral do valor quadrático do sinal adotado como saída do sistema. A metodologia proposta permite especificar um índice de desempenho apenas para aos modos de resposta de interesse do sistema, contornando as limitações das metodologias baseadas em posicionamento regional de polos. A relação entre o valor da energia do sinal de saída do sistema e seu fator de amortecimento é estabelecida por meio de uma equação algébrica. Neste trabalho, a metodologia é aplicada na geração de controladores de amortecimento para geradores síncronos. Entretanto, o procedimento proposto é genérico o suficiente para ser aplicado a outros tipos de geradores (gerador de indução empregado em unidades eólicas, por exemplo), a dispositivos FACTS (do Inglês, Flexible AC Transmission System) assim como a outros tipos de sistemas dinâmicos. A metodologia gerou um controlador eficaz para um caso onde a formulação baseada no tradicional posicionamento regional de polos é incapaz de gerar um controlador que assegure uma boa margem de estabilidade para o modo de resposta de interesse. / This work proposes a methodology for the design of controller to damp low frequency electromechanical oscillations in power systems. The control problem is structured in the form of matrix inequalities, which allows obtaining a numerical solution for the control problem. The damping controllers based on dynamic output feedback, generated by design methodologies in the form of matrix inequalities, usually presents high order. In addition, the design of this controller, considering large power systems, usually requires excessive computational effort. In this context, this work proposes a methodology for the design of reduced order controllers. The proposed methodology employs a performance index that is less costly in terms of computational effort when compared to the one with the traditional regional pole placement. The adopted performance index for the closed loop system is the energy of the system output. This energy corresponds to the integral of the signal squared regarding the system output. The proposed methodology allows specifying a performance index only for the response modes of interest, overcoming the limitations of the methodologies based on regional pole placement. The relation between the energy value of the output signal of the system and its damping factor is established by means of an algebraic equation. In this paper, the methodology is applied to generate damping controller for synchronous generators. However, the proposed procedure is general enough to be applied to other kinds of power plants (wind generation, for example), to FACTS devices, as well as to other dynamic systems. The methodology has generated an effective controller for a case where the formulation based on the regional pole placement is unable to generate a controller which assures a good stability margin for the response mode of interest.
44

Um simulador do controle em tempo real de sistemas de energia eletrica

Kawakami, Regina Morishigue 27 July 2018 (has links)
Orientador: Ariovaldo Verandio Garcia / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-07-27T13:05:23Z (GMT). No. of bitstreams: 1 Kawakami_ReginaMorishigue_M.pdf: 946052 bytes, checksum: c8161543e5e71a1460a743248ceb144a (MD5) Previous issue date: 2000 / Mestrado
45

Alocação otima de reguladores de tensão em redes de distribuição de energia eletrica / Optimal placement of voltage regulators in distribution systems

Pereira, Carlos Alberto Nogueira 13 August 2018 (has links)
Orientador: Carlos Alberto de Castro Junior / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-13T12:20:41Z (GMT). No. of bitstreams: 1 Pereira_CarlosAlbertoNogueira_M.pdf: 1167781 bytes, checksum: 59548f165acd2e595bebd984ef043c53 (MD5) Previous issue date: 2009 / Resumo: Neste trabalho apresenta-se o desenvolvimento de um método heurístico para o dimensionamento e alocação de reguladores de tensão ao longo dos alimentadores primários de sistemas radiais de distribuição de energia elétrica, objetivando a melhoria do perfil de tensão, a minimização das perdas de potência ativa nos trechos de rede e a minimização dos custos de instalação dos equipamentos. O algoritmo desenvolvido para alocação ótima de reguladores de tensão em redes de distribuição radiais é composto por duas etapas. A primeira etapa visa a seleção, a instalação e o ajuste do tap dos reguladores de tensão nas barras que proporcionam melhores condições técnicas (menor desvio de tensão e redução das perdas de potência ativa). Na segunda etapa, procura-se reduzir o número de reguladores de tensão inicialmente alocados, movendo-os adequadamente quando possível até que a melhor condição econômica (mínimos custos de instalação e manutenção) seja obtida. Em conjunto com o desenvolvimento do trabalho, foi elaborado um programa computacional com a finalidade de verificar a funcionalidade e eficiência do método. Foram realizadas simulações em sistemas de distribuição teóricos e reais, sob condições de carga leve e pesada, obtendo-se rapidez e eficiência durante a execução do algoritmo proposto e resultados confiáveis. São apresentados os resultados de simulações para um sistema de 70 barras, e estes são comparados com um método já proposto na literatura. São também apresentados resultados de simulações para redes de distribuição reais de 136 barras, 202 barras e 400 barras / Abstract: This dissertation reports the development of a heuristic method for sizing and allocating voltage regulators in distribution radial primary feeders. The goals are to improve the voltage profile, to minimize the real power losses and to minimize equipment installation and maintenance costs. The proposed algorithm for the optimal allocation of voltage regulators in radial distribution networks comprises two steps. The first step aims to select, install and set the tap of voltage regulators at buses that result in the best technical conditions (smallest voltage deviation and real power losses reduction). In the second step, an attempt is made to reduce the number of voltage regulators initially allocated in the first step, by moving them appropriately until the best economical condition (minimum installation and maintenance costs) is reached. A computational program was implemented to evaluate the efficiency of the proposed method. Simulations have been carried out for theoretical and realistic distribution systems, for light and heavy load conditions, and the method showed to be fast and efficient, providing reliable results. Simulations results for a 70-bus distribution system and the comparison with those provided by another method proposed in the literature are shown. Also, simulation results are shown for realistic 136-, 202-, and 400-bus realistic systems / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica
46

Papel dos controles secundarios numa analise de estabilidade de tensão em regime permanente

Paula, Andre Saraiva de 02 August 2018 (has links)
Orientador : Anesio dos Santos Jr / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-02T13:04:42Z (GMT). No. of bitstreams: 1 Paula_AndreSaraivade_M.pdf: 4368055 bytes, checksum: d01245971b646a02573882bf32ccca8f (MD5) Previous issue date: 2002 / Mestrado
47

Sistema de geração distribuida fontes CA e CC conectado a rede monofasica e controle eletronico da qualidade da energia eletrica / Distribution generator systems with AC and DC sources connected to a single-hase feeder and electronic control of the power quality

Machado, Ricardo Quadros 02 January 2005 (has links)
Orientadores: Jose Antenor Pomilio, Simone Buso / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-04T01:54:00Z (GMT). No. of bitstreams: 1 Machado_RicardoQuadros_D.pdf: 40226020 bytes, checksum: 3daf262738d5d4691a16184af4e741f1 (MD5) Previous issue date: 2004 / Resumo: Esta tese apresenta uma nova forma de conexão direta entre um gerador de indução trifásico e uma rede monofásica, situação típica de ambientes rurais, com possibilidade de geração local de energia. O funcionamento do sistema prevê que seja garantida ao usuário local energia elétrica de boa qualidade. Por energia de boa qualidade entende-se: tensões senoidais e equilibradas, freqüência fixa e boa regulação de tensão. Para a rede monofásica, controla-se o fluxo de potência de modo que o fator de potência resultante seja unitário. A obtenção destes comportamentos se dá com o uso de um conversor CC-CA PWM trifásico, conectado em derivação no ponto de acoplamento das cargas locais. Por este conversor flui uma parcela da potência da carga relacionada com desequilíbrios e distorções. A maior parte da potência ativa não precisa ser processada pelo conversor, o que dá a esta solução um rendimento maior do que se obtém com as alternativas de dupla conversão. O sistema completo de geração distribuída pode receber energia, da geração CA (gerador de indução), de uma fonte CC (células a combustível, painéis fotovoltáicos ou bancos de baterias) conectada ao barramento CC do conversor PWM ou da rede monofásica. No caso de alimentação apenas pela rede, tem-se uma estrutura de conversão mono-trifásica interativa com a linha / Abstract: This thesis proposes a novel solution to connect a three-phase induction generator directly to a single-phase feeder. Typical situations are found in rural areas in which is possible to obtain local power generation. High power quality at the customers such as sinusoidal and balanced voltages, constant frequency and regulated AC voltage, is provided. Additionally, unity power factor on the feeder is obtained. A three-phase shunt voltage source inverter VSI-PWM is connected at the point of common coupling. This converter processes a fraction of the load power that is associated with unbalances, reactive power and harmonics, as well. The efficiency of the partial power processing is higher when compared to double-conversion systems. On the other hand, the system is able to manage a DC source as a fuel cells, a solar panel and batteries. If only the single-phase source is available, the system operates as a single to three-phase line-interactive converter / Doutorado / Energia Eletrica / Doutor em Engenharia Elétrica
48

Controladores repetitivos aplicados a filtros ativos de potência sob variações de carga e de frequência da rede / Repetitive controllers applied to active power filters under load variations and line frequency deviations

Zimmermann, Cristiano Porporatti 03 October 2014 (has links)
Este trabalho apresenta o desenvolvimento e adaptação de técnicas para minimizar os efeitos das variações de carga e de frequência da rede em controladores repetitivos aplicados a filtros ativos de potencia. Para minimizar os efeitos provenientes de sinais aperiódicos decorrentes da conexão ou desconexão de cargas não lineares é elaborada uma técnica que diferencia cargas lineares de não lineares. Esta técnica opera de forma a só reinicializar o controlador quando o erro devido ao transitório for de valor considerável ou quando ocorrer a transição de carga não linear para linear. Também é desenvolvido um algoritmo de adaptação do ganho do controlador repetitivo baseado em uma função de adaptação sigmóide, com intuito de minimizar os efeitos provocados por ruído aleatório no sistema de medição. Na sequência, são analisados os efeitos da variação de frequência e apresentados os principais métodos de compensação deste problema. Entre as soluções apresentadas, encontra-se o método da alteração do número de amostras por período e o método da variação da taxa de amostragem. O primeiro possui a vantagem de utilizar técnicas de projeto lineares e invariantes no tempo. Já o segundo método, por variar a frequência de amostragem, deve ser analisado sob um aspecto de sistema variante no tempo, o que acarreta em maior complexidade na prova de estabilidade. Os algoritmos de reinicialização e adaptação do ganho do controlador repetitivo são analisados sob variação da frequência da rede. Para a compensação da variação da rede, utiliza-se o método do truncamento do número de amostras e o da variação da taxa de amostragem. Por fim, para validar os algoritmos desenvolvidos s˜ao realizados testes em uma plataforma experimental. / This work presents the development and modification of techniques to reduce the effects of load variation and mains frequency deviation in repetitive controllers applied to active power filters. To minimize the effects of aperiodic signals resulting from the connection or disconnection of non-linear loads is developed a technique which recognizes linear and nonlinear loads, and operates to reset the controller only when the error due to the transition of considerable value, and the transition is from non-linear to linear load. An algorithm to adapt the gain of the repetitive controller, based on a sigmoid function adaptation, in order to minimize the effects caused by random noise in the measurement system is also used. This work also analyzes the effects of frequency variation and presents the main methods to cope with this situation. Some solutions are the change in the number of samples per period and the variation of the sampling rate. The first has the advantage of using linear design techniques and results in a time invariant system. The second method changes the sampling frequency and leads to a time variant system that demands a difficult analysis of stability. The proposed algorithms were tested using the methods of truncation of the number of samples and the method of changing the sampling rate of the system to compensate possible frequency variations of the grid. Experimental results are presented to validate the proposal.
49

Desenvolvimento de sensores e instrumentação aplicados no projeto de equipamentos analisadores de qualidade de energia elétrica

Koizumi, Marcos Tsuyoshi 30 November 2012 (has links)
CAPES / Uma má qualidade de energia elétrica gera grandes prejuízos para a sociedade. Desta forma são utilizados equipamentos denominados analisadores de qualidade de energia elétrica para quantizar os valores destes distúrbios e assim determinar as causas destas anormalidades. O grande problema destes equipamentos é o custo elevado e geralmente são importados inviabilizando uma medição multiponto do sistema elétrico do cliente. Neste cenário, este trabalho objetiva fornecer subsídios e alternativas para o desenvolvimento de equipamentos analisadores de qualidade de energia, que consiste de um conjunto com sensores de corrente e tensão e um módulo central de processamento. No desenvolvimento de quaisquer sensores ou instrumentação surgem algumas dificuldades de condicionamento de sinal por causa das características elétricas do componente usado e principalmente por causa do ruído. Alguns meios de contornar estes problemas são a utilização de uma instalação adequada dos equipamentos de medição, blindagens eletromagnéticas e projeto de PCB’s. No caso de sensores magnéticos, a histerese, saturação magnética e as interferências por campos magnéticos externos introduzem erro de medida no sistema e para a resolução destes problemas foram adotadas configurações de sensores Hall em malha fechada e diferencial. Outro componente que pode ser usado é o sensor Flux-gate que possui potencialidade para medições de corrente de pequena ordem além de oferecer a vantagem de maior integrabilidade ao sistema medidor. Na sequência foi projetado e construído um registrador de tensão e corrente para análise de qualidade de energia elétrica, denominado PQ-Logger, que pode usar estes sensores mencionados anteriormente. O uso de um DSP e um chip para acessar um pendrive genérico permite o armazenamento destes dados. O PQ-Logger-Tran é outro equipamento que foi idealizado para armazenar trechos de transiente de média frequência. Os resultados indicam positivamente o uso conjunto destes sensores de corrente e o equipamento desenvolvido para o propósito de medição destes parâmetros de forma rápida e econômica na infraestrutura elétrica do cliente. / A poor quality power causes large losses to society. Thus it is used an equipment named power quality analyzers for magnitude measurement of these disturbances and determine the causes of these abnormality. The principal problem with these devices is the high cost and they usually are imported that invalidates multipoint measurement of client’s electrical system. In this scenario, this work aims to provide support and alternatives for the development of power quality analyzers, which consists of a set with voltage and current sensors and a central processing module. In the development of any sensors or instrumentation there are difficulties on signal conditioning generated from the used component’s electrical characteristics and principally noise. Some solutions for these problems is the use of proper measuring equipment installation, electromagnetic shielding and design of PCBs. For magnetic sensors, the hysteresis, magnetic saturation and interference by external magnetic fields introduce measurement error in the system and to solve these problems it was adopted Hall sensors in closed-loop and differential configurations. Another component that can be used is the Flux-gate sensor that has potential use in small range current measurements and offers the advantage of higher integrability in the meter system. Following is designed and built a voltage and current logger for Power quality analysis, called PQ-Logger that may utilize the sensors mentioned above. The use of a DSP and a chip for accessing a generic flash drive allows storage of these data. The PQ-Logger-Tran is other equipment that was designed to store snippets of mid-frequency transient. The results positively indicate the combined use of these current sensors and equipment developed for the measuring purpose of these parameters in a quickly and economically form in the customer‘s electrical infrastructure.
50

Classificação de eventos em redes de distribuição de energia elétrica utilizando modelos neurais autônomos

Lazzaretti, André Eugênio 06 July 2010 (has links)
Este trabalho apresenta uma metodologia para classificação de eventos de curto-circuito e mano-bras em redes de distribuição de energia elétrica, com base nos registros oscilográficos de tensão na barra da subestação de distribuição. São apresentados os resultados obtidos para duas formas distintas de pré-processamento dos sinais de tensão, sendo a primeira baseada em Transformada de Fourier e a segunda em Transformada Wavelet para diferentes famílias de funções wavelet. Foram comparados três modelos neurais para o processo de classificação: Multi-Layer Perceptron, Radial Basis Function e Support Vector Machine. Os modelos foram treinados levando em conta uma característica autônoma de operação das redes, ou seja, a seleção automática do modelo e o controle de complexidade. Os resultados foram validados para um conjunto de simulações realizadas no programa Alternative Transient Program, visando a aplicação prática do método proposto em um equipamento registrador de oscilografias, desenvolvido pelo Lactec em conjunto com a Copel - Curitiba, PR, denominado Power Quality Monitor. Foram obtidos resultados com desempenho na ordem de 90% de acerto médio para as diferentes formas de pré-processamento e diferente modelos neurais. / This work presents a method for automatic classification of faults and events related to quality of service in power distribution networks, based on oscillographies of the bar feeder voltages of the distribution substation. We present the results for two distinct pre-processing forms of the voltage signals. The first is based on the Fourier Transform and the second on the Wavelet Transform for different families of wavelet functions. We compared three neural models for the process of classification: Multi-Layer Perceptron, Radial Basis Function and Support Vector Machine. The models were trained taking into account the autonomous operation of networks, i.e. automatic model selection and control complexity. The results were validated for a set of simulations performed using the Alternative Transient Program, aimed at practical implementation of the proposed method in an oscillograph logger, developed by Lactec together with Copel, called the Power Quality Monitor. The results were obtained with performance on the order of 90% of average accuracy for the various pre-processing forms and neural models.

Page generated in 0.0268 seconds