Estudo de cogeração em hotéis

Brofman, Eduardo Gus January 2014 (has links)
Este trabalho é um estudo da aplicação de um sistema que utiliza a cogeração para hotéis localizados na cidade de Porto Alegre, RS, Brasil. Foi analisada a implantação desse tipo de sistema, também chamado de CHP (Combined Heat and Power), de um ponto de vista econômico e energético. A questão econômica foi determinada pela viabilidade através de métodos de análise quantitativa, neste caso, dando enfoque ao tempo de retorno do investimento. Para a análise energética foi realizado o estudo dos consumos e demandas anuais da operação do prédio através da ferramenta de simulação térmo-energética de edificações. O software escolhido foi o EnergyPlus. Essas análises, energéticas e econômicas, foram realizadas através de uma comparação entre o hotel sem o sistema de CHP e o hotel com o sistema de CHP. O hotel hipotético simulado foi definido através de um levantamento de informações a respeito do desempenho energético de hotéis que funcionam em Porto Alegre. Além dos estudos energéticos e econômicos, foram realizadas variações em parâmetros do hotel para tentar abranger uma série de possíveis cenários e verificar suas viabilidades econômicas. Foi visto que a cogeração pode trazer redução de custo operacional mesmo não tendo um menor consumo energético anual. Em alguns cenários o tempo de retorno do investimento apresentou valor abaixo dos seis anos, sendo considerado como uma boa opção de investimento. / This work is a study of the application of a CHP (Combined Heat and Power) system in hotels built in the city of Porto Alegre, RS, Brazil. This system was analyzed from an economic and energetic point of view. The economic matter on its viability perspective was determined through quantitative methods, in this case, with the focus on the time frame for the investment's return. For the energetic analysis, a annual energy consumption and demand study was performed utilizing a whole-building energy model with computer simulation. The chosen software was EnergyPlus. The analyses, energetic and economic, were performed through a comparison between the hotel without the CHP system and with the CHP system. The hypothetic simulated hotel was determined by a data survey on the energetic performance of hotels build in Porto Alegre. In addition to the energetic and economic studies, some parametric variations to the hotel were made to include a series of possible scenarios and check their economic viability. It was observed that the CHP can provide some operational cost reductions even without presenting a lower annual energetic consumption. In some scenarios, the time to return the investment showed figures lower than six years, being considered a good investment option.
52

Desenvolvimento de metodologia para avaliação do potencial de utilização de sistemas de energia solar fotovoltaica em meios urbanos

Torres, Rafael Gerzson January 2015 (has links)
Este trabalho visa desenvolver uma metodologia, através de ferramentas computacionais de simulação, de avaliação de mapas solares para a análise de sombreamentos e da radiação solar incidente sobre as coberturas e telhados das edificações dentro do ambiente urbano e aplicá-la para a cidade de Porto Alegre. Desta forma é possível identificar os melhores espaços para alocar futuras instalações fotovoltaicas e evitar possíveis perdas por sombreamento ao longo do ano. Para tanto, foram selecionadas quatro regiões de estudo, cada uma representando uma tipologia de bairro e edificações. Os bairros Centro Histórico, São Geraldo, São Sebastião e Santana foram selecionados por representarem: edificações comerciais de escritórios, galpões comerciais (depósitos e oficinas), residencial de baixa altura e prédios residenciais, respectivamente. Após o desenvolvimento dos mapas solares, são realizadas estimativas para capacidade de instalação e produção de energia elétrica por sistemas fotovoltaicos em cada edificação. O software EnergyPlus produziu modelos termoenergéticos para quatro edificações típicas representando cada uma das regiões de estudo e, assim, proceder um balanço de energia em escala anual para o consumo energético e a produção de energia. Considerando as hipóteses de simulação e premissas de cálculo utilizadas, verifica-se que existe potencial para a geração distribuída de energia em escala urbana para as regiões de estudo. Um resultado significativo ocorreu para a região do bairro São Geraldo, onde as dez maiores áreas de telhado equivalem a 53% do potencial total de instalação fotovoltaica aplicada a edificações da região de estudo. Ainda, realizado o balanço de energia, foram analisados os cenários de investimento para cada tipologia de edificação típica, resultando em um retorno sobre o investimento entre 9 e 13 anos, dependendo do tipo de edificação. / This work aims to develop a methodology, through computer simulation tools, for evaluating solar maps for shading analysis and incident solar radiation on the building roofs within the urban environment. This methodology is applied in the city of Porto Alegre. Thus, it is possible to identify the best areas to allocate future photovoltaic systems and avoid possible shading losses throughout the year. Therefore were selected four study areas, each one representing one type of neighborhood and respective buildings. The neighborhoods Centro Histórico, São Geraldo, São Sebastião and Santana were selected because they represent: commercial/office buildings, warehouses/workshops, low-rise residential and residential buildings, respectively. After the development of solar maps, estimates were made for the capacity of installation and the electric energy produced by photovoltaic systems in each building roof. The EnergyPlus software produced an energy model for a typical building of each study area (neighborhood) and make an energy balance in annual scale for the energy consumption and energy production. Considering the simulation hypothesis and assumptions, it appears that there is potential for the distributed generation in urban scale for the four study areas. A significant result was found for the São Geraldo region, where only the top ten building roof areas equals to 53% of the total potential of building applied photovoltaic in the respective neighborhood region. Also, performing the energy balance, investment scenarios were analyzed for each typical building, resulting in a return on investment between 9 and 13 years, depending on the building type.
53

Estudo de cogeração em hotéis

Brofman, Eduardo Gus January 2014 (has links)
Este trabalho é um estudo da aplicação de um sistema que utiliza a cogeração para hotéis localizados na cidade de Porto Alegre, RS, Brasil. Foi analisada a implantação desse tipo de sistema, também chamado de CHP (Combined Heat and Power), de um ponto de vista econômico e energético. A questão econômica foi determinada pela viabilidade através de métodos de análise quantitativa, neste caso, dando enfoque ao tempo de retorno do investimento. Para a análise energética foi realizado o estudo dos consumos e demandas anuais da operação do prédio através da ferramenta de simulação térmo-energética de edificações. O software escolhido foi o EnergyPlus. Essas análises, energéticas e econômicas, foram realizadas através de uma comparação entre o hotel sem o sistema de CHP e o hotel com o sistema de CHP. O hotel hipotético simulado foi definido através de um levantamento de informações a respeito do desempenho energético de hotéis que funcionam em Porto Alegre. Além dos estudos energéticos e econômicos, foram realizadas variações em parâmetros do hotel para tentar abranger uma série de possíveis cenários e verificar suas viabilidades econômicas. Foi visto que a cogeração pode trazer redução de custo operacional mesmo não tendo um menor consumo energético anual. Em alguns cenários o tempo de retorno do investimento apresentou valor abaixo dos seis anos, sendo considerado como uma boa opção de investimento. / This work is a study of the application of a CHP (Combined Heat and Power) system in hotels built in the city of Porto Alegre, RS, Brazil. This system was analyzed from an economic and energetic point of view. The economic matter on its viability perspective was determined through quantitative methods, in this case, with the focus on the time frame for the investment's return. For the energetic analysis, a annual energy consumption and demand study was performed utilizing a whole-building energy model with computer simulation. The chosen software was EnergyPlus. The analyses, energetic and economic, were performed through a comparison between the hotel without the CHP system and with the CHP system. The hypothetic simulated hotel was determined by a data survey on the energetic performance of hotels build in Porto Alegre. In addition to the energetic and economic studies, some parametric variations to the hotel were made to include a series of possible scenarios and check their economic viability. It was observed that the CHP can provide some operational cost reductions even without presenting a lower annual energetic consumption. In some scenarios, the time to return the investment showed figures lower than six years, being considered a good investment option.
54

Avaliação comparativa do desempenho térmico de painéis de Light Steel Frame pré-fabricados para uso em construções modulares. / Comparative assessment of the thermal performance of pre-fabricated light steel frame panels for use in modular constructions.

Márcio Bernardo 11 April 2017 (has links)
As evoluções tecnológicas juntamente com o surgimento de novas necessidades dos usuários resultaram em diversos novos tipos de métodos construtivos. O conceito de industrialização das edificações vem evoluindo com velocidade, e estes novos sistemas construtivos surgiram como alternativa aos sistemas tradicionais buscando entre outros, melhor desempenho térmico, energético, lumínico, acústico e de sustentabilidade. Diante desta crescente demanda por inovação, a ABNT (Associação Brasileira de Normas Técnicas) passou a estudar um conjunto de normas para estabelecer critérios de desempenho ao validar os novos sistemas construtivos de edificações habitacionais. Isto se concretizou com a publicação da Norma de Desempenho (ABNT NBR 15575/2013), que estipula parâmetros para desempenho dessas construções e métodos detalhados de acordo com o desempenho desejado. Simultaneamente, as simulações computacionais evoluíram, permitindo menor custo de experimentação, são capazes de antecipar resultados antes somente possíveis após testes físicos com protótipos e também a encontrar alternativas de soluções também quanto à eficiência energética e ao conforto dos usuários. Entre alguns programas existentes para simulação de desempenho térmico, está o EnergyPlus, o qual foi utilizado para este estudo, tendo como principal objetivo avaliar o desempenho térmico de painéis de light steel frame pré-fabricados utilizados na fachada e nas vedações internas de um sistema construtivo modular composto por estrutura metálica, e piso e a laje de concreto. Para o desenvolvimento do estudo, foi utilizado como modelo base uma residência térrea, configurada por ambientes independentes, que virão a compor uma residência inteira onde serão inseridos os painéis de light steel frame pré-fabricados. As 16 tipologias de painéis foram estudadas em três diferentes cidades do Brasil, sendo elas situadas nas regiões Nordeste, Sudeste e Sul e em dias típicos de verão e inverno, utilizando os recursos de simulação computacional (EnergyPlus) possibilitando a análise comparativa de desempenho térmico de cada tipologia ao serem submetidos a diferentes temperaturas e regime de insolação. A maioria das tipologias de painéis apresentam resultados favoráveis apenas para a cidade de Fortaleza, e desfavoráveis para as cidades de São Paulo e Curitiba, onde somente a última tipologia de painel atendeu os requisitos mínimos de desempenho para todas as cidades. Este estudo não contempla dados experimentais ou ensaios físicos. / Technological developments coupled with the emergence of new user needs resulted in several types of new construction methods. The concept of building industrialization has been evolving with speed, and these new construction systems have emerged as an alternative to traditional systems. These alternative systems seek better thermal performance, energy efficiency, light performance, acoustic and sustainability, among other things. Faced with this growing demand for innovation, ABNT (Brazilian Technical Standards Association) went on to study a set of rules to establish performance criteria to validate the new construction systems of residential buildings. These criteria were established with the publication of Performance Standard (NBR 15575/2013), which provides detailed parameters for performance of these buildings and provides methods according to the desired performance. At the same time, computer simulations have evolved, allowing lower cost of experimentation. These simulations are able to anticipate results which were previously only possible after physical tests of prototypes and also are able to find alternative solutions for energy efficiency and comfort of users. Among some existing programs for simulating thermal performance is the EnergyPlus, which was used for this study, with the primary objective of evaluating the thermal performance of prefabricated light steel frame panels. These panels were used in the facade and the internal seals of a building system composed of modular steel structure and floor and the concrete slab. To develop the study, a one-story residence was used as a base model, set by independent environments, composed entirely of the prefabricated light steel frame panels. The 16 panel types were studied in three different cities in Brazil, located in the Northeast, Southeast and South, and on a typical day of summer and winter. Using the computer simulation resources (EnergyPlus) enabled comparative analysis of thermal performance of each type when subjected to different temperatures and insolation regime. Most panel types have favorable results only in the city of Fortaleza, and unfavorable in the cities of São Paulo and Curitiba, whereas only the last panel type met the minimum performance requirements for all cities. This study does not include experimental data or physical tests.
55

Demonstrating the significance of microclimate on annual building energy simulations using RadTherm

Sommerfeldt, Nelson January 2012 (has links)
Buildings account for over 35% of the energy demand in OECD countries, making them a prime target for improvement. (EIA 2011) To help building owners reduce energy usage, ratings systems such as LEED have been developed. A prerequisite for certification is the demonstration of energy efficiency through computer modeling; however, the complex nature of building energy simulations too often leads to errors of up to 30% (Turner and Frankel 2008). One source of significant error can be the assumptions made of environmental conditions, which are often simplified to speed up simulations. To demonstrate the significance of active microclimate modeling, a building energy model combined with a microclimate model has been created in RadTherm, a commercial CAE thermal solver. Simulations are run using Passive House construction in three types of environments, and demonstrate an increase in energy demand over an annual time scale when microclimatic components are included. The increase in demand is less than 1%, however the decrease in radiant heat losses are up to 30%. Using the same methodology with revisions to the building construction and urban geometry, a larger increase in energy demand is expected.
56

Heating, ventilating and air-conditioning system energy demand coupling with building loads for office buildings

Korolija, Ivan January 2011 (has links)
The UK building stock accounts for about half of all energy consumed in the UK. A large portion of the energy is consumed by nondomestic buildings. Offices and retail are the most energy intensive typologies within the nondomestic building sector, typically accounting for over 50% of the nondomestic buildings’ total energy consumption. Heating, ventilating and air conditioning (HVAC) systems are the largest energy end use in the nondomestic sector, with energy consumption close to 50% of total energy consumption. Different HVAC systems have different energy requirements when responding to the same building heating and cooling demands. On the other hand, building heating and cooling demands depend on various parameters such as building fabrics, glazing ratio, building form, occupancy pattern, and many others. HVAC system energy requirements and building energy demands can be determined by mathematical modelling. A widely accepted approach among building professionals is to use building energy simulation tools such as EnergyPlus, IES, DOE2, etc. which can analyse in detail building energy consumption. However, preparing and running simulations in such tools is usually very complicated, time consuming and costly. Their complexity has been identified as the biggest obstacle. Adequate alternatives to complex building energy simulation tools are regression models which can provide results in an easier and faster way. This research deals with the development of regression models that enable the selection of HVAC systems for office buildings. In addition, the models are able to predict annual heating, cooling and auxiliary energy requirements of different HVAC systems as a function of office building heating and cooling demands. For the first part of the data set development used for the regression analysis, a data set of office building simulation archetypes was developed. The four most typical built forms (open plan sidelit, cellular sidelit, artificially lit open plan and composite sidelit cellular around artificially lit open plan built form) were coupled with five types of building fabric and three levels of glazing ratio. Furthermore, two measures of reducing solar heat gains were considered as well as implementation of daylight control. Also, building orientation was included in the analysis. In total 3840 different office buildings were then further coupled with five different HVAC systems: variable air volume system; constant air volume system; fan coil system with dedicated air; chilled ceiling system with embedded pipes, dedicated air and radiator heating; and chilled ceiling system with exposed aluminium panels, dedicated air and radiator heating. The total number of models simulated in EnergyPlus, in order to develop the input database for regression analysis, was 23,040. The results clearly indicate that it is possible to form a reliable judgement about each different HVAC system’s heating, cooling and auxiliary energy requirements based only on office building heating and cooling demands. High coefficients of determination of the proposed regression models show that HVAC system requirements can be predicted with high accuracy. The lowest coefficient of determination among cooling regression models was 0.94 in the case of the CAV system. HVAC system heating energy requirement regression models had a coefficient of determination above 0.96. The auxiliary energy requirement models had a coefficient of determination above 0.95, except in the case of chilled ceiling systems where the coefficient of determination was around 0.87. This research demonstrates that simplified regression models can be used to provide design decisions for the office building HVAC systems studied. Such models allow more rapid determination of HVAC systems energy requirements without the need for time-consuming (hence expensive) reconfigurations and runs of the simulation program.
57

Análise da eficiência energética do sistema de condicionamento de ar com distribuição pelo piso em ambiente de escritório, na cidade de São Paulo, utilizando o modelo computacional Energyplus. / Energy efficiency analysis of underfloor air distribution (ufad) system for office rooms, at São Paulo city, using the ENERGYPLUS software.

Inatomi, Thais Aya Hassan 06 May 2008 (has links)
Este trabalho tem por finalidade avaliar o desempenho energético do sistema de condicionamento de ar com distribuição pelo piso (Underfloor Air Distribution System UFAD) em ambientes de escritório, considerando diferentes possibilidades de arquitetura do sistema e seus modos de operação com ciclos economizadores. Por meio de simulação computacional, as avaliações foram realizadas para o clima da cidade de São Paulo ao longo de um ano metereológico típico, mantendo as condições de conforto térmico no ambiente. O programa de simulação selecionado como ferramenta foi o EnergyPlus 2.1.0.023, visto que modelos numéricos nele implementados representam adequadamente o sistema UFAD e os ciclos economizadores. Como referência para o desenvolvimento dos modelos de simulação foi utilizada uma câmara de testes representativa de um ambiente de escritórios. Esta câmara foi desenvolvida por Leite (2003) para avaliação do conforto térmico propiciado pelo sistema UFAD. As curvas de distribuição de temperatura resultantes das simulações foram similares às curvas resultantes das medições executadas por esta autora. As simulações foram realizadas para duas arquiteturas diferentes do circuito de ar (com e sem desvio do ar de retorno) combinados com três diferentes modos de operação relacionados à vazão do ar exterior. A análise dos dados climáticos da cidade de São Paulo demonstra que a tomada de ar exterior pode ser majorada com a utilização de ciclos economizadores, reduzindo o consumo de energia do sistema. Os resultados desta pesquisa indicam uma estreita relação entre arquitetura do sistema, controle dos ciclos economizadores, e dados climáticos, revelando que a combinação entre esses parâmetros pode reduzir em 34,5% o consumo de energia elétrica do sistema UFAD na cidade de São Paulo. / The purpose of this research is to evaluate the energy performance of the Underfloor Air Distribution (UFAD) system at office buildings, considering different air loops design and economizer cycles while keeping thermal comfort for the weather data of São Paulo city, Brazil. Simulations were held using the EnergyPlus software version 2.1.0.023, since its numerical models can well represent UFAD systems and economizer cycles. One chamber representing an office room was used as reference for the simulation models. This chamber was developed by Leite (2003) to evaluate the thermal comfort conditions provided by the UFAD system. The curves of temperature distribution obtained from simulation were similar to those experimentally obtained by Leite (2003). Simulations were performed for two different air loops (with and without return air bypass) combined with three different outside air controls. The São Paulo weather data analysis demonstrates that the outside air flow can be increased with the use of economizer cycles, reducing electric energy consumption of the UFAD system. The results of this research indicate that there is a tight relationship between the system air loop design, economizer cycle control and weather data, which reveals that the combination between these parameters can reduce about 34,5% the electric energy consumption of UFAD system at São Paulo city.
58

Investigação da viabilidade da redução do consumo de energia elétrica em edificações residenciais através da aplicação de soluções de conforto ambiental passivo / Investigation of the viability of reducing energy consumption in residential buildings through the implementation of passive strategies for environmental comfort

Pires, Josiane Reschke 21 March 2013 (has links)
Submitted by Maicon Juliano Schmidt (maicons) on 2015-04-18T14:41:17Z No. of bitstreams: 1 Josiane Reschke Pires.pdf: 4785187 bytes, checksum: 5dcede27f6c8d94cee536d3dfbfa047d (MD5) / Made available in DSpace on 2015-04-18T14:41:17Z (GMT). No. of bitstreams: 1 Josiane Reschke Pires.pdf: 4785187 bytes, checksum: 5dcede27f6c8d94cee536d3dfbfa047d (MD5) Previous issue date: 2013-03-21 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / PROSUP - Programa de Suporte à Pós-Gradução de Instituições de Ensino Particulares / A preocupação com a sustentabilidade sugere a busca pela otimização dos recursos naturais. Um dos aspectos necessários é adequar as edificações para o clima em que estão localizadas, reduzindo o consumo energético da habitação e ampliando o conforto ambiental. O objetivo desta pesquisa é investigar a viabilidade técnica e econômica da aplicação de critérios de desempenho térmico em edificações residenciais. A investigação foi centrada na identificação dos custos e da energia no ciclo de vida de projetos simulados com soluções baseadas em conforto ambiental passivo (natural) e ativo (artificial), verificando a influência no consumo de energia da edificação. Foi aplicada em projetos de edificações residenciais verticais e horizontais, de classe média e baixa, em dois climas distintos (Porto Alegre e Bento Gonçalves, RS), examinando o tipo de envelope, as absortâncias e o uso de elementos construtivos. Para análise do desempenho térmico foi adotada a norma de desempenho NBR 15575 e método graus-hora, com modelagem BIM, utilizando o Revit/Autodesk e para as simulações térmicas foi empregado o EnergyPlus, software especializado em análise energética para edificações. O ciclo de vida dos projetos propostos foi analisado considerando-se um período de 50 anos, comparando os custos e a energia incorporada das alternativas. Como um segundo parâmetro de sustentabilidade, também se analisou a eficiência energética conforme o selo de eficiência energética Procel Edifica. Os resultados indicam que com o aumento do isolamento da envoltória se verifica uma melhoria do conforto térmico, de até 54%, e economia de energia, em ambos os climas, com um período de retorno de 2 a 6 anos, em alguns casos. / The concern with sustainability brought the need for optimization of the energy resources to reduce the consumption of electric energy and of natural resources. One of the aspects is the need to adapt the buildings to the climate in which they are located, reducing the energy consumption of housing. The aim of this research is to investigate the technical and economic viability of applying some criteria of thermal performance in residential buildings. The methodology is based on the identification of the costs and energy in the life cycle of projects based on environmental comfort on passive (natural) and active (artificial) ways, detailing the influence on energy consumption of the building. It was applied in residential projects, both vertical and horizontal, of lower and middle class, in two distinct microclimates (Porto Alegre and Bento Gonçalves, southern Brazilian cities), examining alternatives of envelope, insulation and the use of architectural façade elements. To analyze the thermal performance was adopted the Brazilian standard NBR 15575 and degree-hour method, with BIM modeling through Revit/Autodesk and for the thermal simulation Ecotect/Autodesk and EnergyPlus. The life cycle of the proposed case studies was analyzed by considering a period of 50 years, comparing the costs and embodied energy of alternatives. As a second measure of sustainability, energy efficiency was also analyzed with the Brazilian standard of energy efficiency Procel Edifica. The results showed that with the increment of envelope’s insulation there are improvement of thermal comfort, of 54%, and energetic economy, in both climates, with a payback period of 2 to 6 years, in some cases.
59

Análise da eficiência energética do sistema de condicionamento de ar com distribuição pelo piso em ambiente de escritório, na cidade de São Paulo, utilizando o modelo computacional Energyplus. / Energy efficiency analysis of underfloor air distribution (ufad) system for office rooms, at São Paulo city, using the ENERGYPLUS software.

Thais Aya Hassan Inatomi 06 May 2008 (has links)
Este trabalho tem por finalidade avaliar o desempenho energético do sistema de condicionamento de ar com distribuição pelo piso (Underfloor Air Distribution System UFAD) em ambientes de escritório, considerando diferentes possibilidades de arquitetura do sistema e seus modos de operação com ciclos economizadores. Por meio de simulação computacional, as avaliações foram realizadas para o clima da cidade de São Paulo ao longo de um ano metereológico típico, mantendo as condições de conforto térmico no ambiente. O programa de simulação selecionado como ferramenta foi o EnergyPlus 2.1.0.023, visto que modelos numéricos nele implementados representam adequadamente o sistema UFAD e os ciclos economizadores. Como referência para o desenvolvimento dos modelos de simulação foi utilizada uma câmara de testes representativa de um ambiente de escritórios. Esta câmara foi desenvolvida por Leite (2003) para avaliação do conforto térmico propiciado pelo sistema UFAD. As curvas de distribuição de temperatura resultantes das simulações foram similares às curvas resultantes das medições executadas por esta autora. As simulações foram realizadas para duas arquiteturas diferentes do circuito de ar (com e sem desvio do ar de retorno) combinados com três diferentes modos de operação relacionados à vazão do ar exterior. A análise dos dados climáticos da cidade de São Paulo demonstra que a tomada de ar exterior pode ser majorada com a utilização de ciclos economizadores, reduzindo o consumo de energia do sistema. Os resultados desta pesquisa indicam uma estreita relação entre arquitetura do sistema, controle dos ciclos economizadores, e dados climáticos, revelando que a combinação entre esses parâmetros pode reduzir em 34,5% o consumo de energia elétrica do sistema UFAD na cidade de São Paulo. / The purpose of this research is to evaluate the energy performance of the Underfloor Air Distribution (UFAD) system at office buildings, considering different air loops design and economizer cycles while keeping thermal comfort for the weather data of São Paulo city, Brazil. Simulations were held using the EnergyPlus software version 2.1.0.023, since its numerical models can well represent UFAD systems and economizer cycles. One chamber representing an office room was used as reference for the simulation models. This chamber was developed by Leite (2003) to evaluate the thermal comfort conditions provided by the UFAD system. The curves of temperature distribution obtained from simulation were similar to those experimentally obtained by Leite (2003). Simulations were performed for two different air loops (with and without return air bypass) combined with three different outside air controls. The São Paulo weather data analysis demonstrates that the outside air flow can be increased with the use of economizer cycles, reducing electric energy consumption of the UFAD system. The results of this research indicate that there is a tight relationship between the system air loop design, economizer cycle control and weather data, which reveals that the combination between these parameters can reduce about 34,5% the electric energy consumption of UFAD system at São Paulo city.
60

Development of a Laboratory Verified Single-Duct VAV System Model with Fan Powered Terminal Units Optimized Using Computational Fluid Dynamics

Davis, Michael A. 2010 August 1900 (has links)
Single Duct Variable Air Volume (SDVAV) systems use series and parallel Fan Powered Terminal Units to control the air flow in conditioned spaces. This research developed a laboratory verified model of SDVAV systems that used series and parallel fan terminal units where the fan speeds were controlled by either Silicon Controlled Rectifiers (SCR) or Electronically Commutated Motors (ECM) motors. As part of the research, the model was used to compare the performance of the systems and to predict the harmonics generated by ECM systems. All research objectives were achieved. The CFD model, which was verified with laboratory measurements, showed the potential to identify opportunities for improvement in the design of the FPTU and accurately predicted the static pressure drop as air passed through the unit over the full operating range of the FPTU. Computational fluid dynamics (CFD) models of typical a FPTU were developed and used to investigate opportunities for optimizing the design of FPTUs. The CFD model identified key parameters required to conduct numerical simulations of FPTU and some of the internal components used to manufacture the units. One key internal component was a porous baffle used to enhance mixing when primary air and induced air entered the mixing chamber. The CFD analysis showed that a pressure-drop based on face velocity model could be used to accurately predict the performance of the FPTU. The SDVAV simulation results showed that parallel FPTUs used less energy overall than series systems that used SCR motors as long as primary air leakage was not considered. Simulation results also showed that series ECM FPTUs used about the same amount of energy, within 3 percent, of parallel FPTU even when leakage was not considered. A leakage rate of 10 percent was enough to reduce the performance of the parallel FPTU to the level of the series SCR system and the series ECM FPTUs outperformed the parallel FPTUs at all weather locations used in the study.