• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 64
  • 2
  • Tagged with
  • 66
  • 66
  • 66
  • 65
  • 64
  • 49
  • 41
  • 40
  • 18
  • 17
  • 15
  • 15
  • 15
  • 15
  • 14
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Avaliação tecnológica e clínica de protetores nasais empregados na ventilação não invasiva de recém-nascidos / Clinical and technological assessment of nasal protectors employed in non-invasive ventilation of newborns

Camillo, Débora de Fátima 26 August 2016 (has links)
A lesão nasal decorrente do uso da ventilação não invasiva (VNI) é um evento adverso cada vez mais comum nas unidades de terapia intensiva neonatais (UTIN) e apresenta consequências a curto e longo prazo. Esta lesão pode resultar em sequelas tanto de ordem estética quanto funcional, limitar o uso da VNI em RN que necessita desse suporte ventilatório, causar desconforto e septicemia; podendo aumentar, desta forma, o tempo de internamento na UTIN. Esta pesquisa tem por objetivo avaliar tecnológica e clinicamente os protetores nasais empregados na VNI de RN internados na UTIN. A metodologia consistiu primeiramente em levantar as possíveis causas da lesão nasal e avaliar os fatores de risco associados ao seu desenvolvimento. Em seguida, foi realizado um ensaio clínico randomizado para comparar os efeitos de três tipos de proteção nasal e das prongas novas e esterilizadas sobre a gravidade da lesão nasal. E por fim, foi realizada a caracterização térmica e estrutural dos protetores nasais após serem envelhecidas com temperatura e umidade no interior da incubadora neonatal. As principais causas da lesão foram relacionadas às características do material, a problemas no equipamento, a fatores assistenciais, neonatais e profissionais. Neste estudo, foram constatados como fatores de risco: a idade gestacional, a massa ao nascer, o tempo total de permanência na VNI, a reutilização deste suporte, o tempo da primeira utilização e da reutilização da VNI, bem como o tempo de internação na UTIN. Não foram observadas diferenças significativas na gravidade da lesão quando comparadas as três proteções estudadas, nem quando utilizadas prongas novas e esterilizadas. Quanto à análise dos materiais, foi constatado que a exposição à temperatura e à umidade alterou a percentagem de cristalinidade e a rugosidade das proteções nasais estudadas. / The nasal injury resulting from the use of non-invasive ventilation (NIV) is an adverse event increasingly common in the newborn intensive care unit (NICU) and shows the short and long term consequences. This lesion can result both aesthetic and functional sequelae, limit the use of NIV in newborns who need this ventilatory support, cause discomfort and septicemia, may thereby increase the length of stay in NICU. This research aims to evaluate technological and clinically nasal protectors used with NIV of newborns admitted to the NICU. The methodology consisted primarily in raising the possible causes of nasal injury and assess the risk factors associated with its development. Then, it was conducted a randomized clinical trial to compare the effects of three kind of nasal protector and new and sterilized prongs on the severity of nasal lesions. And finally, it was performed the thermal and structural characterization of nasal protection after being aged with temperature and humidity inside the neonatal incubator. The main causes of injury were related to characteristics of the material, equipment problems, assistive, neonatal and professional factors. In this study, it was found as risk factors: gestational age, weight at birth, the total time stay in the NIV, the reuse of this support, the time of first use and reuse of NIV and the length of stay in the NICU. They were not observed significant differences in lesion severity when compared the three protectors studied, nor when used new and sterilized prongs. The materials analysis indicated that exposure to temperature and humidity changed the percentage of crystallinity and the roughness of the nasal protections studied.
62

Aplicação da baropodometria no desenvolvimento de um protocolo de avaliação motora em crianças nascidas pré-termo após a aquisição da marcha / Baropodometry application in developing a motor evaluation protocol in preterm infants born after the acquisition of march

Coldebella, Cristiane 31 August 2016 (has links)
O nascimento prematuro contribui significativamente para o aumento de morbidades associadas ao desenvolvimento motor, tornando fundamental o acompanhamento contínuo destas crianças. Desta forma, a avaliação baropodométrica, por consistir em um método quantitativo de controle postural pode trazer vantagens para o diagnóstico e acompanhamento do desenvolvimento motor de crianças. Este estudo teve por objetivo desenvolver um protocolo de avaliação motora através dos dados e índices baropodométricos em crianças nascidas pré-termo. Foi realizado um estudo descritivo, onde foram avaliadas 103 crianças entre 24 e 59 meses. Destas, 40 nascidas pré-termo e 63 crianças nascidas a termo. Durante a seleção da amostra, foi preenchida uma ficha de avaliação correspondente ao pré-termo grupo e um questionário com relatos dos pais no grupo a termo. Após, foram aferidos massa corporal e estatura, seguida da aplicação da Escala de Desenvolvimento Motor. Por fim, a baropodometria foi realizada na forma estática, em três repetições, os quais consistiram de 5 segundos de adaptação da criança dobre a placa e 30 segundos onde foram aferidos dados de análise estática: pressão plantar e área do centro de oscilação corporal. Após, as pressões plantares foram transformadas em índices, o índice ânteroposterior foi definido pelas pressões plantares anterior e posterior: IAP= 1-2*│0,6-P│; e o índice látero-lateral, por sua vez, foi definido pelas pressões plantares laterais direita e esquerda: ILL= 1-│LD-LE│. Após a avaliação os dados foram submetidos ao teste de normalidade das distribuições de Shapiro-Wilk, após verificada a distribuição não-normal, foi aplicado o teste de Mann-Whitney para verificar diferença entre os grupos, a associação entre os valores obtidos pelo baropodômetro, Escala do Desenvolvimento Motor, e as principais características e intercorrências do grupo pré-termo foi verificada através da correlação de Spearman. Foi observada diferença significativa nos valores de ILL (p=0,000) entre crianças nascidas a termo e crianças nascidas pré-termo, e que esta diferença possui correlação moderada com a idade gestacional (ρ=0,304), em relação ao centro de oscilação de pressão, crianças nascidas a termo apresentaram menor oscilação quando comparado a idade cronológica (ρ=-0,354), sendo que esta relação foi contrária em crianças nascidas pré-termo (ρ=0,336). Quando analisado somente o grupo pré-termo, foi verificado que o ILL apresentou correlação moderada e inversa com o tempo de internação (ρ=-0,353) e com o tempo de ventilação mecânica (ρ=-0,317) e a aérea do centro de oscilação de pressão apresentou correlação moderada e direta com o tempo de ventilação não invasiva (ρ=0,341). A massa ao nascer apresentou correlação moderada com o ILL (ρ=0,359) e também com a idade motora (ρ=0,323) e o quociente motor (ρ=0,341) e correlação forte com a IG (ρ=0,898) em contrapartida o peso atual apresentou correlação moderada com o quociente motor (ρ=0,310), e a IG (ρ=0,381) e correlação forte com a idade motora (ρ=0,555) e a idade cronológica (ρ=0,613). Houve diferença significativa em relação a idade de aquisição da marcha das crianças que precisaram de acompanhamento fisioterapêutico das que não precisaram (p=0,013). Um índice ILL menor em prematuros, pode estar relacionado ao tempo de internação e ventilação mecânica, além da massa ao nascer, já a maior aérea do centro de oscilação de pressão possui correlação com o tempo de ventilação não invasiva. Também pode-se perceber que a massa atual e a idade cronológica influenciaram mais no desenvolvimento motor que a massa ao nascer e a idade gestacional em crianças prematuras. / Preterm birth contributes significantly to the increase of morbidities associated with motor development, making essential the continuous monitoring of these children. Thus, baropodometry analysis by consisting of a quantitative method for postural control can be advantageous for the diagnosis and monitoring of engine development of children. This study aimed to develop a motor evaluation protocol through the data and baropodometric indexes in preterm infants. It was a descriptive study, which were evaluated 103 children between 24 and 59 months. Of these, 40 preterm and 63 term infants. During the sample selection was completed an evaluation form with data from medical records corresponding to the pre-term group and a questionnaire to parents on group term. After, body mass and height were measured, then the implementation of the Motor Development Scale. Finally, baropodometry was held in static form, with three replicates, which consisted of 5 seconds of child adjustment bend the plate and 30 seconds which were measured static analysis data: plantar pressure and pressure swing center area. After, the plantar pressures were transformed into indexes, the anteroposterior index was defined by the anterior and posterior plantar pressures: API = 1-2 * │0,6-P│; and side side index, in turn, defined by the right and left side planter pressure: SSI = 1- │RS-LS│. After evaluating, the data were submitted to normality test of Shapiro-Wilk distributions, being checked the non-normal distribution, the Mann-Whitney test was used to verify differences between groups, the association between the values obtained by baropodometry analysis, Motor Development Scale, and the main characteristics and complications of preterm group was verified by Spearman correlation. Significant difference in the values of SSI (p = 0.000) among term infants and infants born preterm were observed, and this difference has moderate correlation with gestational age (ρ = 0.304) compared to the pressure oscillation center , full-term babies showed less fluctuation compared to chronological age (ρ = -0.354), and this relationship was contrary in preterm children (ρ = 0.336).When only analyzed the preterm group, it was found that the SSI had moderate and inverse correlation with the length of stay (ρ = -0.353) and the duration of mechanical ventilation (ρ = -0.317) and the air oscillation center pressure showed moderate and direct correlation with noninvasive ventilation time (ρ = 0.341).The mass at birth showed moderate correlation with SSI (ρ = 0.359) and also with the motor age (ρ = 0.323) and the ratio engine (ρ = 0.341) and strong correlation with gestational age (ρ = 0.898) in contrast current weight showed moderate correlation with the motor quotient (ρ = 0.310) and gestational age(ρ = 0.381) and strong correlation with the motor age (ρ = 0.555) and chronological age (ρ = 0.613). There was significant difference in the age of acquisition of march of the children who needed physical therapy monitoring of those who did not needed (p = 0.013). A smaller SSI index in premature infants, may be related to hospitalization time and mechanical ventilation, in addition to mass at birth, already the largest air pressure oscillation center has correlation with noninvasive ventilation time.It may also be seen that the current mass and chronological age influenced more motor development than the mass at birth and gestational age in preterm children.
63

Protocolo de verificação do processo de esterilização por vapor de formaldeído / Verification protocol of the formaldehyde steam sterilization process

Borini, Júlio Cesar 08 December 2016 (has links)
Este trabalho apresenta o estudo do processo de esterilização de materiais e instrumentais cirúrgicos em autoclaves que se utilizam do agente esterilizante, o vapor à baixa temperatura de formaldeído. Processo esse utilizado para materiais termosensiveis, ou seja, que não suportam temperaturas superiores a 80°C. Assim objetivo desse trabalho, foi avaliar essa tecnologia de esterilização a baixa temperatura, que já é utilizada há mais de 20 anos em vários países, inclusive aqui no Brasil, porém com pouco detalhes de estudos conclusivos sobre o assunto na literatura nacional e internacional. Este estudo foi baseado nas Normas ABNT NBR 15659 e NF EN ISO 25424 que tratam especificamente dos requisitos, métodos e cuidados na esterilização de vapor a baixa temperatura e formaldeído, implementando um protocolo de verificação para estudo da tecnologia. Para tanto foi elaborada uma metodologia de avaliação, da instalação de esterilizadores que utilizam como agente esterilizante o formaldeído. Na verificação da eficácia da metodologia 3 tipos de equipamentos de esterilização foram testados. Os equipamentos testados são de fabricação brasileira (02 deles) e um de fabricação sueca. Os testes foram feitos em 6 hospitais, onde foram avaliados desde a sua instalação, avaliação dos parâmetros de tempo, temperatura e pressão (com equipamentos calibrados e rastreados pelo INMETRO), avaliação do nível de resíduos no material (com laudos feitos por laboratórios credenciados), uso de indicadores de processo (biológicos e químicos), avaliação ambiental (ar e saída do dejeto para o esgoto), controles de manutenções preventivas e segurança do operador (EPI). Todos os ciclos avaliados apresentaram resultados dentro dos parâmetros mínimos sugerido na Norma ABNT NBR 15659 e NF EN ISO 25424. Concluindo que se seguindo rigorosamente o que pede a Norma e os manuais dos fabricantes dos equipamentos, pode-se perfeitamente obter um processo seguro de esterilização para o Hospital, e atender todos os níveis de segurança tanto para o operador como para o paciente que irá usar o material processado no ciclo de esterilização. / This work presents the study of the sterilization process of surgical materials and instruments in autoclaves using the sterilizing agent, the low temperature vapor of formaldehyde. This process is used for thermosensitive materials, is they do not withstand temperatures above 80 ° C. The objective of this study was to evaluate the low temperature sterilization technology, which has been used for more than 20 years in several countries, including here in Brazil, but with little details of conclusive studies on the subject in the national and international literature. This study was based on the ABNT NBR 15659 and NF EN ISO 25424 standards that specifically deal with the requirements, methods and care in low temperature steam sterilization and formaldehyde, implementing a verification protocol for technology study. For this, an evaluation methodology was elaborated for the installation of sterilizers that use formaldehyde as the sterilizing agent. In the verification of the effectiveness of the methodology 3 types of sterilization equipment were tested. The equipment tested is of Brazilian manufacture (02 of them) and one of Swedish manufacture. The tests were carried out in 6 hospitals, where they were evaluated since its installation, evaluation of parameters of time, temperature and pressure (with equipment calibrated and tracked by INMETRO), evaluation of the level of residues in the material (with reports made by accredited laboratories), use of process indicators (biological and chemical), environmental assessment (air and exits to the sewage), preventive maintenance controls and operator safety (EPI). All the evaluated cycles presented results within the minimum parameters suggested in the Standard ABNT NBR 15659 and NF EN ISO 25424. Concluding that strictly following the norms and the manuals of the equipment manufacturers, it is perfectly possible to obtain a safe process of sterilization To the Hospital, and meet all levels of safety for both the operator and the patient who will use the material processed in the sterilization cycle.
64

Determinação do melhor método para prever o alcance à junção craniovertebral nas cirurgias endoscópicas transnasais utilizando neuronavegação / Definition of the best method to predict the extent of endoscopic transnasal surgery to the cranio vertebral junction using neuronavigation

Aurich, Lucas Alves 31 March 2017 (has links)
Espera-se redução das complicações cirúrgicas quando lesões localizadas na junção craniovertebral (JCV) são operadas pelo acesso cirúrgico endoscópico transnasal ao invés do acesso transoral. Entretanto, não se sabe ainda qual seria o maior alcance inferior da abordagem transnasal e também qual seria o melhor método para prever o limite de exposição no planejamento pré-operatório. No presente estudo, o alcance à JCV foi definido no período intraoperatório com neuronavegação em 10 pacientes operados pela via transnasal. O limite anatômico obtido foi comparado com as linhas nasopalatina e palatina. A linha nasopalatina mostrou ser o melhor método para prever o alcance inferior à JCV. / It is expected reduction of surgical complications when craniovertebral junction pathologies are operated using the endoscopic transnasal approach instead of the transoral approach. However, it is yet unclear what is the lower extent of the transnasal approach and which method is better to predict this lower limit in preoperative planning. This study evaluates the inferior exposure of craniocervical junction in 10 patients operated through the transnasal approach using neuronavigation. The intraoperative anatomical limit was compared to nasopalatine and palatine lines. The nasopalatine line predicts more accurately the inferior limit of the transnasal approach.
65

Modelos matemáticos para estimativa da gordura corporal de adolescentes utilizando dobras cutâneas, a partir da absorciometria de raios-X de dupla energia / Mathematical models for the estimation of the fat mass of adolescents based on skinfold thickness, using dual-energy X-rays absorptiometry

Ripka, Wagner Luis 07 April 2017 (has links)
Introdução: Estudos têm encontrado uma transição da obesidade da população adulta para crianças e adolescentes, que por sua vez, pode acarretar manifestações clínicas, como: doenças coronarianas, diabetes tipo 2, e complicações psicossociais cada vez mais precocemente. Contudo, métodos para avaliação da composição corporal para essa faixa etária, principalmente envolvendo técnicas de baixo custo como as medidas de dobras cutâneas (DC) apresentam imprecisões em estudos brasileiros. Fator o qual pode levar a uma interpretação equivocada da composição corporal dos avaliados. Objetivo: desenvolver novos modelos matemáticos utilizando medidas de DC, tendo como referência a absorciometria de raios-X de dupla energia (DXA), para estimativa de massa de gordura (G) em adolescentes. Métodos: Trata-se de um estudo exploratório descritivo onde foram avaliados 416 adolescentes do gênero masculino de 12 a 17 anos, sendo 42 destinados para compor a amostra de validação da pesquisa. Foram coletadas medidas de massa corporal total, estatura, circunferência da cintura e quadril, nove pontos anatômicos baseados em DC: bíceps, tríceps, subescapular, peitoral, axilar média, abdominal, supra-ilíaca, coxa e panturrilha, além da G e densidade mineral óssea (DMO) aferida com a tecnologia de DXA. Para o desenvolvimento das equações foi utilizado um modelo de regressão linear múltipla através do método de mínimos quadrados ordinários (OLS). Resultados: O grupo apresentou índice de massa corporal (IMC) médio de 21,25±4,12kg/m² e %G = 20,57±5,80%. A partir do %G, a prevalência de excesso de gordura foi verificada em 38,3% dos adolescentes. O impacto da gordura na DMO dos adolescentes indicou uma associação na ordem de r = -0,358; p<0,005, sendo verificada redução de até 14% da DMO para a região da coluna em adolescentes com obesidade em comparação aos eutróficos. O desenvolvimento de novos modelos matemáticos que atendessem critérios de alto coeficiente de determinação (R²), baixo erro padrão de estimativa (EPE), controle de colinearidade, normalidades dos resíduos, homoscedasticidade e praticidade, possibilitaram a apresentação de três opções com R² = 0,932 e EPE 1,79; R² = 0,912 e EPE = 1,78; R² = 0,850 e EPE = 1,87, respectivamente. Em todas as opções, as variáveis idade e estatura foram empregadas, bem como as DC de tríceps e subescapular. Conclusão: Os resultados obtidos evidenciam a possibilidade de desenvolvimento de novos modelos matemáticos para a avaliação da gordura corporal em adolescentes com resultados superiores aos modelos existentes na literatura. / Introduction: Studies have found a transition from obesity of the adult population to children and adolescents, which in turn, can lead to clinical manifestations, such as: coronary diseases, type 2 diabetes, and psychosocial complications increasingly early. However, methods for evaluating nutritional status for this age group, mainly involving low cost techniques such as skinfold thickness measurements (ST), are imprecise in Brazilian studies. Factor which can lead to a mistaken interpretation of the body composition of the evaluated ones. Objective: To develop new mathematical models, based on DC measurements, based on dual energy X-rays absorptiometry (DXA), to estimate fat mass (G) in adolescents. Methods: This was an exploratory descriptive study in which 416 male adolescents aged 12 to 17 years were evaluated, 42 of whom were separated to compose the study validation sample. Measurements of total body mass, stature, waist and hip circumference were obtained, nine anatomical points based on ST: biceps, triceps, subscapular, pectoral, mid axillary, abdominal, suprailiac, thigh and calf muscles, as well as G and bone mineral density (BMD) measured with DXA technology. For the development of the equations, a multiple linear regression model was used by the ordinary least square (OLS) method. Results: The group had a mean body mass index (BMI) of 21.25± 4.12 kg / m² and %G = 20.57 ± 5.80%. From %G, the prevalence of excess fat was verified in 38.3% of adolescents. The impact of fat on adolescent BMD indicated an association in the order of r = -0.358; P <0.005, with BMD reduction up to 14% for the spine region in adolescents with obesity compared to eutrophic. The development of new mathematical models that meet criteria of high coefficient of determination (R²), low standard error of estimation (SEE), control of colinearity, residue normalities, homoscedasticity and practicality, allowed the presentation of three options with R² = 0.932 and SEE 1.79; R² = 0.912 and SEE = 1.78; R² = 0.850 and SEE = 1.87, respectively. In all the options, the variables age and height were employed, as well as triceps and subscapular ST. Conclusion: The results obtained evidenced the possibility of developing new mathematical models for the evaluation of body fat in adolescents with results superior to the existing models in the literature.
66

Development and evaluation of an elderly fall detection system based on a wearable device located at wrist / Desenvolvimento e avaliação de um sistema de detecção de quedas de idosos baseado em um dispositivo vestível localizado no punho

Quadros, Thiago de 31 August 2017 (has links)
A queda de idosos é um problema de saúde mundial. Todos os anos, cerca de 30% dos idosos com 65 anos ou mais são vítimas de quedas. Além disso, as consequências de uma queda podem ser fisiológicas (e.g. fraturas ósseas, ferimentos musculares) e psicológicas, como a perda de autoconfiança, levando a novas quedas. Uma solução para este problema está relacionada com ações preventivas (e.g. adaptação de mobília) aliadas a sistemas de detecção de quedas, os quais podem notificar familiares e serviços médicos de urgência. Como o tempo de espera por socorro após uma queda está relacionado com a severidade das consequências dela, esses sistemas devem oferecer elevada acurácia e detecção em tempo real. Embora existam várias soluções para isso na literatura (a maioria relacionada com dispositivos vestíveis), poucas delas estão relacionadas a dispositivos de punho, principalmente por causa dos desafios existentes para essa configuração. Considerando o punho como um local mais confortável, discreto e aceitável para uso de um dispositivo (menos associado com o estigma do uso de uma solução médica), este trabalho propõe o desenvolvimento e avaliação de uma solução baseada nessa configuração. Para isso, diferentes sensores (acelerômetro, giroscópio e magnetômetro) foram combinados com diferentes algoritmos, baseados em métodos de limiar e aprendizado de máquina, visando definir os melhores sinais e abordagem para a detecção de quedas. Esses métodos consideraram informações de aceleração, velocidade, deslocamento e orientação espacial, permitindo o cálculo de componentes verticais do movimento. Para o treino e avaliação dos algoritmos, dois protocolos diferentes foram empregados: um primeiro envolvendo 2 voluntários (homens, 27 e 31 anos) simulando um total de 80 sinais de queda e 80 de não-queda, e um segundo envolvendo 22 voluntários (14/8 homens/mulheres, idade média: 25,2 ± 4,7) simulando um total de 396 sinais de queda e 396 de não-queda. Uma análise exaustiva de diferentes sinais e parâmetros de configuração foi executada para cada método. O melhor algoritmo baseado em limiar considerou sinais de aceleração vertical e velocidade total, alcançando 95,8% de sensibilidade e 86,5% de especificidade. Por outro lado, o melhor algoritmo de aprendizagem de máquina foi o baseado no método K-Nearest Neighbors, considerando informações de aceleração, velocidade e deslocamento verticais combinadas com os ângulos de orientação espacial: 100% de sensibilidade e 97,9% de especificidade. Os resultados obtidos permitem enfatizar a relevância de algoritmos de aprendizagem de máquina para sistemas de detecção de queda vestíveis localizados no punho quando comparados a algoritmos baseados em limiar. Esta conclusão oferece grande contribuição para a pesquisa de detectores de quedas similares, sugerindo a melhor abordagem para novos desenvolvimentos. / Falls in the elderly age are a world health problem. Every year, about 30% of people aged 65 or older become victims of fall events. The consequences of a fall may be physiological (e.g. bone fractures, muscular injuries) and psychological, including the loss of self-confidence by fear of falling, which leads to new falls. A solution to this problem is related to preventive actions (e.g. adapting furniture) allied to fall detection systems, which can alert family members and emergency medical services. Since the response time for help is related to the fall's consequences and severity, such systems must offer high accuracy and real-time fall detection. Although there are many fall detection solutions in literature (most part of them related to wearable devices), few of them are related to wrist-worn devices, mainly because of the existing challenges for this configuration. Considering the wrist as a comfortable, discrete and acceptable place for an elderly wearable device (less associated to the stigma of using a medical device), this work proposes the development and evaluation of a fall detection solution based on this configuration. For this, different sensors (accelerometer, gyroscope and magnetometer) were combined to different algorithms, based on threshold and machine learning methods, in order to define the best signals and approach for an elderly fall detection. These methods considered acceleration, velocity and displacement information, relating them with wrist spatial orientation, allowing the calculation of the vertical components of each movement. For the algorithms' training and evaluation, two different protocols were employed: one involving 2 volunteers (both males, ages of 27 and 31) performing a total of 80 fall and 80 non-fall events simulation, and the other involving 22 volunteers (14/8 males/females, ages mean: 25.2 ± 4.7) performing a total of 396 fall and 396 non-fall events simulation. An exhaustive evaluation of different signals and configuration parameters was performed for each method. The best threshold-based algorithm employed the vertical acceleration and total velocity signals, achieving 95.8% and 86.5% of sensitivity and specificity, respectively. On the other hand, the best machine learning algorithm was based on the K-Nearest Neighbors method employing the vertical acceleration, velocity and displacement information combined with spatial orientation angles: 100% of sensitivity and 97.9% of specificity. The obtained results allow to emphasize the relevance of machine learning algorithms for wrist-worn fall detection systems instead of traditional threshold-based algorithms. These results offer great contributions for the research of similar wearable fall detectors, suggesting the best approach for new developments.

Page generated in 0.0341 seconds