• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 137
  • 2
  • Tagged with
  • 140
  • 72
  • 72
  • 46
  • 43
  • 34
  • 28
  • 24
  • 22
  • 20
  • 20
  • 18
  • 17
  • 16
  • 16
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Utilização da espectroscopia Raman para monitorar a cura de tintas epóxi aplicadas em tanques de armazenamento de petróleo / USE OF RAMAN SPECTROSCOPY FOR MONITORING THE CURE OF EPOXY PAINT APPLIED IN OIL STORAGE TANKS

Medeiros, Viviana Maria Mello de 02 March 2010 (has links)
Conselho Nacional de Desenvolvimento Científico e Tecnológico / Epoxy paints are organic coatings applied on the metal surface and hindering the contact surface with the corrosive medium. The condition of curing a resin is of fundamental importance because it affects the mechanical behavior of crosslinked resin. This paper aims to present a study monitoring the curing process of two types of epoxy paints, primer and finishing with the variation of temperature and time, Since the polyamide as curing agent in paint primer and polyamine in paint topcoats. The technique of Raman spectroscopy was used to monitor the cure of epoxy resin and the technique of thermogravimetric analysis (TGA) was used only to verify the onset of degradation temperature of each specific component. The crosslinking process was monitored by Raman spectroscopy for 12 hours consecutive, obtained by heating in Raman spectrometer at temperatures of 50, 100, 125 and 150°C and room temperature for nine days. The monitoring results indicate that cure of the paint primer showed better cure temperature to 100°C with the best curing time around 4 hours and the topcoat with curing temperature of 50°C with the best curing time around 8 hours. / As tintas epóxi são revestimentos orgânicos aplicados sobre a superfície metálica e que dificultam o contato da superfície com o meio corrosivo. A condição de cura de uma resina é de fundamental importância, pois afeta o comportamento mecânico da resina reticulada. Esta dissertação tem por objetivo apresentar um estudo do monitoramento do processo de cura de dois tipos de tintas epóxi, primer e de acabamento, com variação da temperatura e do tempo, tendo a poliamida como agente de cura nas tintas primer e a poliamina nas tintas de acabamento. A técnica de espectroscopia Raman foi utilizada para monitorar a cura da resina epóxi e a técnica de análise termogravimétrica (TGA) foi utilizada apenas para verificar o início da temperatura de degradação de cada componente específico. O processo de reticulação foi monitorado por espectroscopia Raman por 12h consecutivas, obtidos com aquecimento no espectrômetro Raman nas temperaturas de 50, 100, 125 e 150°C e a temperatura ambiente por nove dias. Os resultados do monitoramento da cura indicam que a tinta primer mostrou melhor temperatura de cura a 100°C com melhor tempo de cura em torno de 4h, bem como a tinta de acabamento com temperatura de cura de 50°C com melhor tempo de cura em torno de 8h.
82

Estudo da reocinética de cura de resinas epoxídicas por meio de diferentes técnicas de análise / Study of cure reokinetic of epoxy resins by different analytical techniques

Mariane Martim Sobrosa Passos de Abreu 24 September 2008 (has links)
As aplicações comerciais e científicas das resinas epoxídicas dependem diretamente da combinação entre resina/endurecedor/acelerador, tornando-o um sistema reativo bastante complexo, cuja determinação dos seus parâmetros de cura é um problema multivariável de tempo, temperatura e concentração de reagentes. É necessário o conhecimento de suas etapas de cura e de seu mecanismo cinético para obtenção das melhores propriedades mecânicas, elétricas e térmicas, com a finalidade de conseguir uma resina epoxídica de alto desempenho. As técnicas analíticas comumente empregadas na determinação da cura de resinas epoxídicas como também de diversas outras resinas poliméricas são: a calorimetria exploratória diferencial (DSC) e a análise dinâmico-mecânica (DMA). Neste trabalho, dois sistemas reativos foram analisados: o primeiro, resultante da combinação de resina DGEBA com endurecedor à base de amina alifática; o segundo composto pela resina DGEBA reagida com endurecedor à base de anidrido e catalisado por amina terciária. É apresentada a metodologia empregada na determinação dos parâmetros cinéticos para os dois sistemas epóxi utilizando a análise por DSC isotérmica e não isotérmica, a técnica DMA isotérmica, e como complementos análises isotérmicas por análise reológica e análise dielétrica (DEA) para determinação dos tempos de gelificação e vitrificação que caracterizam cada um dos distintos estágios de cura. Enquanto o sistema epóxi-amina se caracteriza por uma cinética de reação rápida, o sistema epóxi-anidrido apresenta cinética de reação lenta, sendo necessária a adição do acelerador para acelerar a reação, que é otimizada em altas temperaturas. O modelo cinético de Sourour-Kamal e o método Isoconversional foram aplicados respectivamente aos dados experimentais isotérmicos e não-isotérmicos de DSC para obtenção de constantes de reação do sistema. Os resultados encontrados apresentaram excelente concordância com o descrito na teoria de que é possível detectar estágios de cura pelas técnicas de análise dielétrica e dinâmico-mecânica. Também é possível comprovar a eficácia do modelo de Sourour-Kamal, pois apresenta um excelente ajuste com os dados experimentais, enquanto o método Isoconversional, é eficiente na previsão do tempo de cura isotérmico de resinas epoxídicas a partir de dados experimentais não-isotérmicos. As energias de ativação encontradas para as resinas epóxi-amina e epóxi-anidrido tem correspondência com o descrito na literatura. Conclui-se que as técnicas analíticas utilizadas neste trabalho são complementares entre si. / The commercial and scientific applications of epoxy resins depend upon the combination between resin/curing agents/catalyst, turning it a reactive system relatively complex, whose cure parameters determination is a multivariable problem of time, temperature and reagents concentration. It is necessary the knowledge of its curing kinetics mechanism to obtain the best mechanical, electrical and thermal properties, aiming at get high performance epoxy resins. The analytical techniques mostly used in cure determination of epoxy resins as well as in other polymeric thermoset resins are the Differential Scanning Calorimetry (DSC) and the Dynamic Mechanical Analysis (DMA). In this work, two reactive systems were analyzed: the first, based on DGEBA resin with aliphatic amine hardener; the second, composed by DGEBA resin cured by anhydride hardener and tertiary amine catalyst. It is presented the methodology used to determinate the kinetics parameters for the two epoxy systems utilizing isothermal and non-isothermal analysis by Differential Scanning Calorimetry; isothermal analysis by Dynamic Mechanical Analysis, and complementarly Rheological analysis and Dielectric Analysis for determining gelation and vitrification times which describe each one of distinct cure steps. The epoxy-amine system is characterized by a fast reaction kinetic, while the epoxy-anhydride system presents low reaction kinetic, being necessary the addiction of a catalyst for accelerating the reaction, which is improved at high temperatures. The kinetic model of Sourour-Kamal and the Isoconversional method were applied to obtain the kinetics parameters to the isothermal and non-isothermal DSC data, respectively. The experimental results presented good agreement with the theory, making possible to detect the cure stages by dielectric and dynamic mechanical analyses. It is also observed the efficiency of Sourour- Kamal model, because it presented an excellent fitting with the experimental data, while the Isoconversional method is efficient to predict the isothermal cure time by the non-isothermal experimental data. The calculated activation energies for both epoxy-amine and epoxyanhydride resins have agreed with the literature values. The DMA and DEA analytical techniques are complementary between themselves.
83

Blindagem balística de compósito polimérico contra o vandalismo e proteção UV para cadeias de isoladores de vidro em linhas de transmissão

de Almeida Yanaguizawa de Carvalho, Juliana 31 January 2008 (has links)
Made available in DSpace on 2014-06-12T23:14:26Z (GMT). No. of bitstreams: 2 arquivo8648_1.pdf: 10444515 bytes, checksum: 3b4615e6fb38812cb81e860a88235fcc (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2008 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O objetivo deste trabalho foi induzir a absorção UV de vidros soda-cal sílica por irradiação gama, bem como avaliar as propriedades mecânicas, elétricas e a microestrutura do policarbonato (PC), com e sem tratamento térmico, e do compósito epóxi-vidro, com a finalidade de se obter um protótipo para linhas de transmissão composto por uma cadeia de isoladores de vidro absorvedor de radiação UV solar e escudos balísticos contra a quebra da parte vítrea por vandalismo. Vidros soda-cal sílica foram irradiados com fonte de 60Co em doses de 0,5 kGy a 50 kGy e apresentaram um aumento substancial na absorção UV: o comprimento de onda de corte (cut-off) passou de 295 nm para valores acima de 600 nm, dependendo da dose de irradiação. Notou-se a instabilidade dos centros de cor induzidos pela irradiação gama acima de 10 kGy, em temperatura ambiente, através de medidas de densidade óptica relativa e alterações nos espectros UV-Vis monitoradas por cerca de um ano e dois meses. A estabilização dos centros de cores induzidos ocorreu em torno de 40 dias após a irradiação. Ensaios de alta tensão numa cadeia com dezesseis isoladores de vidro, sendo nove quebrados (condição de isolamento mínimo) em diferentes arranjos, mostraram que a colocação de escudos de PC não prejudicou o desempenho elétrico da cadeia. Ademais, a distribuição uniforme dos isoladores inteiros ao longo da cadeia foi responsável pelo maior valor de tensão disruptiva. Propriedades mecânicas do PC e compósito epóxi-vidro foram avaliadas por ensaios de tração, impacto Charpy e medidas de microdureza. A análise termogravimétrica mostrou que até 300°C não houve perda de massa no compósito e PC; foi obtida uma correlação linear positiva entre a temperatura de transição vítrea e a rigidez dielétrica desses materiais. No entanto, o tratamento térmico do PC até 180°C no forno elétrico, acima da temperatura de transição vítrea, ocasionou a formação de bolhas no interior das amostras, indicando um estágio de degradação do material caracterizado por maior microdureza, menor rigidez dielétrica e fragilização do polímero em relação ao PC íntegro. Um dispositivo de impacto foi desenvolvido especialmente para simular o impacto de projéteis de armas de fogo em laboratório e avaliar a resistência ao impacto de isoladores de vidro e escudos balísticos. No ensaio balístico com munições e armas diversas, incluindo carabina Puma 38, o material compósito epóxi-vidro na espessura de 10 mm protegeu todos os isoladores de vidro em cadeia um desempenho não obtido com o PC de 12 mm
84

Síntese de biopolímeros a partir de óleo de mamona para aplicações médicas / Biopolymers synthesis from castor oil for medical applications

Parada Hernández, Natalia Lorena, 1982- 27 August 2018 (has links)
Orientador: Maria Regina Wolf Maciel / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Química / Made available in DSpace on 2018-08-27T14:16:37Z (GMT). No. of bitstreams: 1 ParadaHernandez_NataliaLorena_D.pdf: 3619653 bytes, checksum: 89e5fe01b39a1e7b4df6202248e4f9c5 (MD5) Previous issue date: 2015 / Resumo: O objetivo desta pesquisa é sintetizar um biopolímero a partir do óleo de mamona usando um processo não tóxico, tanto na síntese da resina epoxídica quanto no processo da sua cura, visando obter assim um biomaterial com características adequadas para uso na área médica. Para isso, foi necessária a funcionalização do óleo de mamona, por meio do processo de epoxidação, para posterior utilização como monômero na síntese do biopolímero. O processo de epoxidação foi realizado utilizando um sistema catalítico verde (H2O2/Al2O3/acetato de etila). Inicialmente, foi realizada a epoxidação do ricinoleato de metila (componente modelo), para a avaliação da eficiência do processo de epoxidação. Neste estudo foi utilizada a metodologia de planejamento de experimentos, a qual possibilitou definir as variáveis significativas do processo de epoxidação. A epoxidação do componente modelo foi monitorada por meio de Cromatografia Gasosa acoplada a um Detector de Ionização de Chama (GC-FID). Os resultados mostraram alta conversão (99%), em poucas horas de reação (2h), e ausência de subprodutos (99% de seletividade). Com esses resultados, procedeu-se com a epoxidação do óleo de mamona, cuja eficiência do processo foi avaliada por meio de Espectroscopia no Infravermelho por Transformada de Fourier (FTIR) e Espectroscopia Raman (FT-Raman) e Ressonância Magnética Nuclear de Prótons (1HNMR). Após epoxidação do óleo de mamona, foi avaliada a reação de polimerização do óleo de mamona epoxidado (ECO) usando ácidos carboxílicos (ácido cítrico) como comonômero, utilizando a técnica de Calorimetria Exploratória Diferencial (DSC), FTIR, Análise Termogravimétrica (TGA) e testes de capacidade de inchamento. Os resultados obtidos indicam que o processo de polimerização estudado é viável, obtendo-se um poliéster reticulado. Visando a possível aplicação do poliéster obtido na engenharia de tecidos e área médica, foi realizada a análise de citotoxicidade do polímero obtido, usando células Vero (fibroblastos). O resultado da análise de citotoxicidade mostrou a não toxicidade do polímero sintetizado em células Vero (fibroblastos) / Abstract: The target of this research is to synthesize a biopolymer from castor oil using a nontoxic process, not only in the epoxy resin synthesis but also in its curing process, aiming to obtain a biomaterial with suitable characteristics for medical applications. With this purpose, castor oil was functionalized using an epoxidation process in order to be used as monomer in the biopolymer synthesis. Epoxidation process was performed using a green catalytic system (H2O2/Al2O3/ethyl acetate). Initially, it was carried out the epoxidation of methyl ricinoleate (model compound) for evaluating the epoxidation process efficacy by using experimental design methodology, allowing in this way to define the significant epoxidation process variables. Model compound epoxidation was monitored by gas chromatography equipped with a flame ionization detector (GC-FID). The evaluation of the results showed high conversion (99%) in a few hours (around 2hs) without byproduct formation (99% selectivity). Taking into account these results, it was performed the castor oil epoxidation and the process efficacy was evaluated by Fourier transform infrared (FT-IR), Raman Spectroscopy and 1H NMR. After castor oil epoxidation, epoxidized castor oil (ECO) polymerization using carboxylic acids (citric acid) as comonomer was evaluated by Differential Scanning Calorimetry (DSC), FTIR, Thermogravimetric Analyses (TGA) and swelling tests. The obtained results showed that polymerization process is viable and it was obtained a cross-linked polyester. In order to evaluate the potential application of the obtained polymer in the medical field, it was performed a cytotoxicity assay using Vero cells (fibroblast type). Cytotoxicity results showed nontoxic effect of synthesized polyester on Vero cells / Doutorado / Engenharia Química / Doutora em Engenharia Quimica
85

Cura de compósitos de sistemas epóxi via irradiação de micro-ondas. / Cure of epoxy systems composites by microwave irradiation.

Kersting, Daniel de Freitas 25 June 2014 (has links)
De modo geral, os ciclos de cura para resina epóxi demandam algumas horas e elevadas temperaturas. Em busca de novas soluções para a otimização de processos sem perda de qualidade, bem como a economia de energia, diversos processos de cura de resina epóxi não convencionais foram desenvolvidos ao longo dos anos. O uso de irradiação de micro-ondas teve início após a Segunda Guerra Mundial, com a invenção do RADAR. A radiação de micro-ondas é uma radiação não-ionizante, com bom poder de penetração e boa transferência de calor em materiais absorvedores, ou materiais com cargas absorvedoras. A frequência usualmente utilizada em trabalhos de pesquisa e desenvolvimento é de 2,45GHz, a mesma disponível nos equipamentos comerciais e industriais existentes. Para a cura de resinas epóxi não são necessárias alterações no sistema reativo, com iniciadores específicos sensíveis a micro-ondas. O \"efeito micro-ondas\" proporciona um aumento da velocidade de colisão entre os reagentes que, associada à energia absorvida pelo sistema reacional, acelera a reação de cura, possibilitando a cura de resinas de tempo de uso longo (superior a 24 horas, em temperatura ambiente) em questão de minutos. Neste estudo foi utilizado inicialmente um sistema epóxi do tipo DGEBA, com endurecedor à base de anidrido e acelerador à base de amina, nas mesmas condições comerciais indicadas pelo fabricante. Testes iniciais com os fornos de micro-ondas selecionados foram realizados previamente a operação com sistemas epóxi. A cura do sistema já catalisado foi realizada em dois diferentes fornos de micro-ondas adaptados para uso em laboratório. A temperatura de degradação, e a temperatura de transição vítrea, foram avaliadas por técnicas de análise térmica. Cargas, pigmentos e aditivos também foram avaliados, no sentido de determinar suas influências em misturas com o sistema epóxi escolhido. Após estudos preliminares com o sistema epóxi puro, foram realizados testes em compósitos reforçados com fibra de vidro. Os resultados indicam que o processo é promissor, correspondendo ao observado em diversos artigos na literatura. / Generally, the cure cycles epoxy resin demand for few hours, and elevated temperatures. In search of new solutions for process optimization without loss of quality as well as energy saving, various processes of curing epoxy resin unconventional were developed over the years. The use of microwave irradiation began after World War II, with the invention of RADAR. The microwave radiation is non-ionizing radiation, with good power of penetration and good heat transfer in absorbing materials, or materials with absorbing fillers. The frequency usually used in research and development is of 2.45 GHz, the same is available in commercial equipment. For curing epoxy resins are not necessary changes in the system reactive with specific initiators sensitive to microwaves. The \"microwave effect\" provides increased on collision velocity between the reactants, which combined with energy absorbed by the reaction system, its accelerates the reaction curing, allowing the resin to cure long pot-life (times greater than 24 hours) in minutes. In this study, a DGEBA epoxy resin with an anhydride based hardener, and an initiator based on amine was used under the same conditions indicated by the manufacturer. Preliminary tests with the microwave ovens selected were executed before the operation with epoxy systems. The curing of the catalyzed system was performed in two different adapted microwave ovens for use in laboratory. The degradation temperature and the glass transition temperature were evaluated by thermal analysis techniques. Fillers, pigments and additives also were evaluated to determinate the influences with and without the epoxy system. After previous tests with the epoxy system alone, it was realized tests in composites form with glass fiber. The initial results indicate that the curing process by microwave irradiation is promising, and corresponding with the literature.
86

Estudo e desenvolvimento de metodologia para fixação de iodo radioativo em substrato polimérico para confecção de fontes utilizadas em braquiterapia / Study and development of methodology for fixing iodine in radioactive sources used for polymeric substrate production in brachytherapy

Rodrigues, Bruna Teiga 21 August 2015 (has links)
O câncer é hoje a segunda maior causa de morte por doenças em vários países, inclusive no Brasil, sendo um dos problemas de saúde pública mais complexos. O câncer de próstata é o mais comum em homens no Brasil, desconsiderando o de pele do tipo não melanoma. A braquiterapia é uma modalidade da radioterapia na qual fontes radioativas seladas são colocadas dentro ou em contato com o órgão a ser tratado, uma das formas de tratamento para esse tipo de câncer. O radioisótopo mais utilizado é o iodo-125, que se apresenta fixado em um substrato de prata que é selado em uma cápsula de titânio. A técnica exige o implante de 80 a 120 sementes por paciente, sendo este tratamento considerado um procedimento de baixo impacto e não cirúrgico. A maioria dos pacientes pode retornar à atividade normal dentro de um a três dias, com pouca ou nenhuma dor. Este trabalho propõe a construção de um modelo de semente alternativo às sementes atualmente em uso, com a finalidade de reduzir o custo das mesmas. Para atingir esse objetivo, este trabalho buscou obter maior eficiência na fixação do iodo radioativo, utilizando um substrato polimérico. Foram desenvolvidos cinco métodos para a fixação do iodo-125 nesses substratos. Os parâmetros analisados nos experimentos foram: tipo de polímero, tempo de imersão, tipo de reação (estática ou dinâmica), concentração da solução de iodo radiativo, atividade específica da solução, necessidade do uso de carreador e a forma química do iodo radioativo. O estudo desses experimentos definiram o método mais eficaz da fixação do iodo no material polimérico (resina epóxi). Foram avaliados os rendimentos da reação de fixação, a atividade do iodo no substrato polimérico, a variação da distribuição da atividade num lote de núcleos poliméricos e a eficiência da resina epóxi em selar a semente. / Cancer is currently the second leading cause of death by disease in several countries, including Brazil. Prostate cancer is the most common among men. Brachytherapy is a modality of radiotherapy in which radioactive seeds are placed inside or in contact with the organ to be treated. The most widely used radioisotope in prostate brachytherapy is iodine- 125, which is presented fixated on a silver substrate that is subsequently placed inside a titanium capsule. A large dose of radiation is released only in the targeted tumor protecting healthy surrounding tissues. The technique requires the application of 80 - 120 seeds per patient. The implants of seeds have low impact and are non-surgical procedures. Most patients can return to normal life within three days with little or no pain. This work proposes an alternative to the seeds that have already been developed, in order to reduce the cost by obtaining a better efficiency on fixing the radioactive iodine onto the epoxy resin. Methods have been developed to perform the fixation of iodine-125 onto polymeric substrates. The parameters analyzed were the immersion time, type of static or dynamic reaction, concentration of the adsorption solution, the specific activity of the radioactive source, the need for carrier and chemical form of the radioactive iodine. These experiments defined the most effective method to fixate the iodine onto the polymeric material (epoxy resin), the iodine activity in the polymeric substrate, the variation of the distribution of activity in a plot of polymeric cores and the efficiency of the epoxy resin to seal the seed.
87

Avaliação da resistência estática e em fadiga de compósitos de fibra de carbono/epóxi e fibra de vidro/epóxi sob cisalhamento modo iosipescu.

Vanderlei de Oliveira Gonçalves 09 December 2010 (has links)
Os materiais compósitos têm sido cada vez mais utilizados principalmente na indústria aeroespacial devido à sua característica de baixa massa específica aliada à alta resistência mecânica, tanto estática quanto em fadiga. Estruturas aeronáuticas e aeroespaciais sofrem, durante operação em serviço, esforços mecânicos de tração, compressão, flexão e cisalhamento. Muitas vezes esses esforços ocorrem de maneira combinada. Dentre esses esforços, o de cisalhamento é, sem dúvida, o mais complexo de avaliação devido à heterogeneidade, anisotropia e baixa resistência, que pode causar a falha prematura da estrutura. Dentre os métodos de ensaio para avaliação de propriedades em cisalhamento, o método Iosipescu, pelo fato de ser simples e eficaz para a obtenção da resistência (?) e do módulo em cisalhamento interlaminar ou no plano, tem recebido aceitação pela comunidade científica. O presente trabalho propõe-se a caracterizar as propriedades estáticas, resistência e módulo em cisalhamento, e avaliar a vida em fadiga, por meio do método Iosipescu, para uma resina epóxi e para compósitos com matriz em resina epóxi reforçados com tecido de fibras de vidro e tecido de fibras de carbono. A partir de resultados estáticos de cisalhamento no plano foram realizados ensaios de fadiga e obtidas curvas S-N com duas razões de tensão diferentes, R=0,1 e 0,5, frequência de 12 Hz, carregamento cíclico constante na forma senoidal e limite máximo de 120 000 ciclos. Os valores de ?12 e G12 obtidos estaticamente e em fadiga são comparados entre os materiais ensaiados. A resina epóxi sem reforço apresenta o menor módulo e limite de fadiga, seguida pelos compósitos orientados a 0/90 e, finalmente, pelos compósitos orientados a 45. Observa-se também que, em todos os materiais, a vida em fadiga é maior para R=0,5, devido principalmente ao comportamento viscoelástico da resina epóxi.
88

Caracterização da tenacidade à fratura interlaminar de um material compósito de fibra de carbono-epoxi

Diogo Jundi Toyoda 15 May 2009 (has links)
Embora os materiais compósitos possuam diversas vantagens em relação aos metálicos, uma de suas desvantagens é a baixa resistência à delaminação, um dos modos mais comuns de falha de estruturas em materiais compósitos. O objetivo deste trabalho é obter valores de resistência à fratura interlaminar, para um laminado com camadas de carbono-epoxi a 0 pré-impregnadas, à temperatura ambiente. Foram realizados os ensaios DCB (Double Cantilever Beam) para o modo I (abertura), 4ENF (Four Point End Notched Flexure) para modo II (cisalhamento) e MMB (Mixed Mode Bending) para o modo misto. Os ensaios DCB e MMB seguiram normas ASTM, enquando o 4ENF foi realizado seguindo procedimentos desenvolvidos pelo MERL (Materials Engineering Research Laboratory). O ensaio MMB foi realizado com as razões de mixidade de 25, 50 e 75%. Além disso, foi avaliado o método de redução de dados CBBM (Compliance Based Beam Method) para o ensaio DCB, no qual não é necessário medir o comprimento de delaminação durante o ensaio. Finalmente, foi discutida a correlação entre e através do envelope de falha do material e a influência do uso de tecido de fibra de carbono nos resultados de tenacidade à fratura interlaminar.
89

Estudo da reação de formação de adutos gerados por resina epóxi e polialquileno glicóis. / Study of the reaction of adducts formation generated by epoxy resins and polyalkylene glycols.

Alonso, Thiago Vinícius 21 February 2013 (has links)
A reação entre resinas epóxi e polialquileno glicóis gera um aduto de elevado peso molecular que pode ter aplicações em diferentes segmentos, tais como polímeros usados na composição base de fluidos de têmpera, viscosificantes para lubrificantes e desemulsificantes de petróleo. As condições envolvendo a formação destes adutos possuem referências limitadas na literatura aberta e basicamente envolvem um polialquileno glicol com diferentes funcionalidades, tipicamente duas hidroxilas reagindo com os grupos epóxi presentes na resina epóxi que tipicamente possui funcionalidade igual a dois, a uma temperatura ao redor de 120°C na presença de catalisador de hidróxido de potássio (KOH). O presente trabalho avaliou a formação destes adutos considerando um delineamento experimental de resolução III onde as variáveis de controle foram temperatura, velocidade de agitação do meio reacional, velocidade de adição de resina epóxi, concentração de catalisador e relação molar entre a resina epóxi e o polialquileno glicol. Ao total onze experimentos foram realizados de acordo com o planejamento experimental e incluindo triplicata para avaliação do erro experimental. Diferenças significativas nas características físico químicas dos produtos obtidos tais como viscosidade, teor de epóxi residual e de performance de desemulsificação foram encontradas. Dois produtos apresentaram gelificação. Com um bom nível de confiabilidade estatística pode-se dizer que o peso molecular ponderal médio é influenciado principalmente pelo teor de catalisador seguido da temperatura e proporção molar entre resina epóxi e polialquileno glicol nesta ordem de importância. Com menor nível de significância a conversão é influenciada positivamente com respeito ao incremento do teor de catalisador e da temperatura e pela redução na proporção molar entre resina epóxi e polialquileno glicol. Apesar de terem sido atingidos elevados níveis de conversão de resina epóxi na maioria dos experimentos, pelas analises de GPC foi observado uma grande proporção de polialquileno glicol livre residual nos produtos. Pode-se observar também uma fraca correlação estatística positiva entre a qualidade da separação petróleo-água com respeito à conversão e ao peso molecular numérico médio dos produtos. / The reaction between epoxy resins and polyalkylene glycols generates an adduct of high molecular weight that may have applications in several sectors such as polymers for metal quenchant fluids, demulsifiers and viscosifiers for lubricating oil. The conditions involving the formation of these adducts have limited references in the open literature and basically it involves a polyalkylene glycol having different functionalities, typically two hydroxyl groups reacting with the epoxy groups present in the epoxy resin with typical functionality equal to two at a temperature around 120°C and in the presence of catalyst, potassium hydroxide (KOH). This study evaluated the formation of these adducts considering a resolution III experiment design where the controllable variables were temperature, stirring speed of the reaction medium, rate of addition of epoxy resin, catalyst concentration and molar ratio between the epoxy resin and polyalkylene glycol . In total eleven experiments were carried out according to the experimental design, including three replications at the center point to evaluate the experimental error. Significant differences in chemical and physical characteristics such as viscosity, residual epoxy content and performance of demulsification were found between the synthesized materials. Two products showed gelation. With a good level of statistical reliability it can be considered that the weight average molecular weight is mainly influenced by the amount of catalyst followed by temperature and mole ratio of epoxy resin to polyalkylene glycol in this order of importance. With lower significance level conversion is influenced positively with respect to the increment of the catalyst amount and temperature and by the decrease in molar ratio of epoxy resin and polyalkylene glycol. Despite achieving high levels of conversion of epoxy resin in most of the experiments, by GPC analysis it was observed a large proportion of free residual polyalkylene glycol in the products. It can be observed also a slight positive statistical correlation between the quality of oil-water separation with respect to conversion and number average molecular weight of the products.
90

Cura de compósitos de sistemas epóxi via irradiação de micro-ondas. / Cure of epoxy systems composites by microwave irradiation.

Daniel de Freitas Kersting 25 June 2014 (has links)
De modo geral, os ciclos de cura para resina epóxi demandam algumas horas e elevadas temperaturas. Em busca de novas soluções para a otimização de processos sem perda de qualidade, bem como a economia de energia, diversos processos de cura de resina epóxi não convencionais foram desenvolvidos ao longo dos anos. O uso de irradiação de micro-ondas teve início após a Segunda Guerra Mundial, com a invenção do RADAR. A radiação de micro-ondas é uma radiação não-ionizante, com bom poder de penetração e boa transferência de calor em materiais absorvedores, ou materiais com cargas absorvedoras. A frequência usualmente utilizada em trabalhos de pesquisa e desenvolvimento é de 2,45GHz, a mesma disponível nos equipamentos comerciais e industriais existentes. Para a cura de resinas epóxi não são necessárias alterações no sistema reativo, com iniciadores específicos sensíveis a micro-ondas. O \"efeito micro-ondas\" proporciona um aumento da velocidade de colisão entre os reagentes que, associada à energia absorvida pelo sistema reacional, acelera a reação de cura, possibilitando a cura de resinas de tempo de uso longo (superior a 24 horas, em temperatura ambiente) em questão de minutos. Neste estudo foi utilizado inicialmente um sistema epóxi do tipo DGEBA, com endurecedor à base de anidrido e acelerador à base de amina, nas mesmas condições comerciais indicadas pelo fabricante. Testes iniciais com os fornos de micro-ondas selecionados foram realizados previamente a operação com sistemas epóxi. A cura do sistema já catalisado foi realizada em dois diferentes fornos de micro-ondas adaptados para uso em laboratório. A temperatura de degradação, e a temperatura de transição vítrea, foram avaliadas por técnicas de análise térmica. Cargas, pigmentos e aditivos também foram avaliados, no sentido de determinar suas influências em misturas com o sistema epóxi escolhido. Após estudos preliminares com o sistema epóxi puro, foram realizados testes em compósitos reforçados com fibra de vidro. Os resultados indicam que o processo é promissor, correspondendo ao observado em diversos artigos na literatura. / Generally, the cure cycles epoxy resin demand for few hours, and elevated temperatures. In search of new solutions for process optimization without loss of quality as well as energy saving, various processes of curing epoxy resin unconventional were developed over the years. The use of microwave irradiation began after World War II, with the invention of RADAR. The microwave radiation is non-ionizing radiation, with good power of penetration and good heat transfer in absorbing materials, or materials with absorbing fillers. The frequency usually used in research and development is of 2.45 GHz, the same is available in commercial equipment. For curing epoxy resins are not necessary changes in the system reactive with specific initiators sensitive to microwaves. The \"microwave effect\" provides increased on collision velocity between the reactants, which combined with energy absorbed by the reaction system, its accelerates the reaction curing, allowing the resin to cure long pot-life (times greater than 24 hours) in minutes. In this study, a DGEBA epoxy resin with an anhydride based hardener, and an initiator based on amine was used under the same conditions indicated by the manufacturer. Preliminary tests with the microwave ovens selected were executed before the operation with epoxy systems. The curing of the catalyzed system was performed in two different adapted microwave ovens for use in laboratory. The degradation temperature and the glass transition temperature were evaluated by thermal analysis techniques. Fillers, pigments and additives also were evaluated to determinate the influences with and without the epoxy system. After previous tests with the epoxy system alone, it was realized tests in composites form with glass fiber. The initial results indicate that the curing process by microwave irradiation is promising, and corresponding with the literature.

Page generated in 0.0268 seconds