• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 133
  • 33
  • 8
  • 1
  • Tagged with
  • 181
  • 181
  • 66
  • 56
  • 42
  • 36
  • 32
  • 28
  • 26
  • 24
  • 23
  • 23
  • 21
  • 20
  • 19
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
91

Optimisation de la filière Filtre Planté de Roseaux appliquée au traitement des effluents domestiques pour différents niveaux de performances / Optimization of French Vertical Flow Treatment Wetlands applied to domestic wastewater treatment for different levels of performances

Ruiz, Hernan 27 October 2017 (has links)
Les limites de rejets deviennent de plus en plus strictes pour les petites collectivités et les zones sensibles à l’eutrophisation. L’objectif est de mettre en conformité les collectivités au titre des nouvelles obligations (jusqu’au 15 mgNGL.L⁻¹ et 2 mgPtot.L⁻¹) avec une attention particulière sur l’amélioration du traitement des eaux usées des petites collectivités (< 2000 EH).En France, l'utilisation de stations d’épuration par filtres plantés de roseaux (FPR) pour traiter les effluents domestiques de petites communautés (< 2 000 EH) a suivi une augmentation exponentielle au cours des dernières années. La filière de FPR classique permet de bonnes performances épuratoires en termes de MES, DCO et TKN, néanmoins ce procédé présente de faibles taux de dénitrification (NGL) et d'élimination du phosphore (PTOT).L’objectif de ce travail de thèse a été de développer des solutions innovantes pour le traitement des eaux usées domestiques pour les petites collectivités < 2000 EH en utilisant différentes voies d’intensifications et de combinaison de procédés. Une approche intégrée a été suivie avec des expériences en laboratoire, et une étude sur pilotes en conditions réelles pendant 26 mois. Une comparaison des résultats obtenus sur les pilotes avec des résultats obtenus sur des démonstrateurs de pleine échelle a également été effectuée.L’utilisation de zéolite a permis d’améliorer les performances par l’adsorption de NH4-N, avec des concentrations inférieures à 15 mg.L⁻¹ en été, dans une configuration plus profonde des filtres (95 cm) avec de dispositifs d’aération passive. Cependant, des fluctuations ont été observées à baisses températures.Une configuration basée sur la combinaison de conditions non saturées – saturés pour favoriser la pour l’élimination de NGL a été évaluée. De la même façon, la zéolite a permis d’améliorer l’élimination de NH₄-N et favoriser la nitrification. Les concentrations en sortie ont été de 40 et 52 mgNGL.L⁻¹ pour le filtre de zéolite et gravier respectivement.L'utilisation de la recirculation à pleine échelle a permis d'améliorer les performances dans un seul étage non saturé/saturé. Ces résultats sont toutefois préliminaires dans la mesure où ces stations sont en période de démarrage et de maturation et que peu de Bilan 24h étaient disponibles, ce qui rend difficile la comparaison avec les pilotes. / Discharge limits are becoming increasingly stringent for small communities and sensitive eutrophication areas. The objective is to established new community obligations by setting environmental quality targets (up to 15 mgNGL.L⁻¹ and 2 mgPtot.L⁻¹) especially to the improvement of wastewater treatment in small communities (<2000 p.e). In France, the use of Treatment Wetlands to treat domestic wastewater from small communities (<2 000 p.e.) has increased exponentially in recent years. The classical Vertical Flow Treatment Wetland (VFTW) enable very good performances removal in terms of TSS, COD and TKN, nevertheless denitrification (TN) and phosphorus removal (Ptot) are limited. The aim of this work was to develop innovative solutions, allowing the reduction of the footprint and the improvement of the classical French VFTW in terms of nitrogen (N) removal. An integrated approach was followed with pilot scale experiments and full scale systems using real wastewater during 26 months. A comparison between results of pilots and full-scale was also carried out.The use of zeolite allowed to improve the performances by the adsorption of NH₄-N, with lower concentrations in summer (15 mg.L⁻¹), using a compact filter (95 cm) with passive aeration pipes. However, fluctuations were observed at low temperatures decreasing the removal performances.Similarly, a configuration based on the combination of unsaturated-saturated conditions for NGL removal was evaluated. The zeolite was used in the unsaturated layer to improve the NH₄-N removal and nitrification. Indeed, it has been observed that the zeolite improves the purifying performance compared to a filter filled only with gravel. The outlet concentrations were 40 and 52 mgNGL.L⁻¹ for zeolite and gravel filters respectively.The use of recirculation in full scale systems has improved removal performances in unsaturated / saturated single stage. However, these are preliminary results as these stations are in the start-up and maturation period, few 24 h samples were available, which makes the comparison difficult.
92

Impact of biological pre-treatment on membrane fouling and micropollutant rejection in water recycling / Impact du pré-traitement biologique sur le colmatage membranaire et la réjection des micropolluants en recyclage des eaux usées

Ayache, Chrystelle 28 February 2013 (has links)
Une des solutions alternatives les plus fiables contre la raréfaction des ressources en eau et la dégradation de leur qualité est la réutilisation des eaux usées. Aujourd'hui la technologie membranaire basse et haute pression s'impose comme la technologie de choix pour la production directe et indirecte d'eau potable du fait de la très haute qualité de l'eau produite. Néanmoins, le colmatage des membranes, affectant techniquement et économiquement les filières de traitement, reste aujourd'hui l'un des principaux défis. Les objectifs de cette thèse sont d'améliorer la compréhension du colmatage membranaire dans le recyclage des eaux usées en étudiant le rôle de la qualité de l'effluent secondaire sur le développement du colmatage et l'impact du colmatage sur la qualité de l'eau produite. Afin d'atteindre ces objectifs, une meilleure connaissance de la qualité des effluents secondaires et de leur impact sur les procédés membranaires s'avère indispensable. Les différentes fractions organiques des effluents ont été caractérisées à l'aide de techniques innovantes telles que la spectroscopie de fluorescence à 3 dimensions (EEM) et la chromatographie liquide couplée à une détection carbone (LC-OCD). Une unité à échelle pilote, composée d'ultrafiltration suivie d'une osmose inverse à deux étages, a été mise en place sur deux sites distincts. Plusieurs doses de monochloramine ont été testées (0 à 2 mg/L NH2Cl) afin de donner des recommandations d'optimisation de traitement. / One of the most reliable alternative solutions to water shortage and scarcity in urban areas is potable reuse of what would otherwise be considered "waste" water. The combination of low and high-pressure membrane processes is the favoured technology for direct and indirect potable water recycling due to the very high water quality produced. Despite the fact that membrane technology is well established, membrane fouling remains a major challenge affecting plant operation technically and economically. This thesis aims to contribute to the understanding of membrane fouling in water reuse by investigating the importance of the feed water quality on fouling development and the impact of the fouling on the treated water quality. In order to achieve these objectives, it was important to develop better knowledge of the impact of feed water quality on the membrane process. The organic composition of the effluents was successfully differentiated with the use of advanced analytical tools such as fluorescence excitation emission matrix (EEM) and liquid chromatography-organic carbon detection (LC-OCD). To evaluate water quality impact on membrane fouling, a membrane pilot unit consisting of ultrafiltration and a two stage reverse osmosis train was operated on two different sites. Different monochloramine dosages (0 to 2 mg/L NH2Cl) were applied and their impact on RO membrane performance was studied in order to provide recommendations for plant design.
93

Bio-electro-Fenton : optimization of electrochemical advanced oxidation process in the perspective of its combination to a biological process for the removal of pharmaceuticals from wastewater / Bio-électro-Fenton : optimisation d'un procédé électrochimique d'oxydation avancée en vue de sa combinaison avec un procédé biologique pour l'élimination des produits pharmaceutiques des eaux usées

Ganzenko, Oleksandra 10 December 2015 (has links)
La pollution des ressources en eau est un des défis importants auquel les Hommes doivent faire face. En particulier, de nouvelles solutions doivent émerger, puisque les techniques conventionnelles de traitement utilisées actuellement ne permettent pas une élimination efficace des divers polluants. Parmi les polluants émergents, les composés pharmaceutiques ont récemment été détectés dans différentes sources d'eau à travers le monde. Leurs effets indésirables sur l'environnement naturel et sur l'Homme ont déjà été reconnus mais doivent encore être éclaircis. De nombreux nouveaux procédés de traitement de l'eau apparaissent. En particulier, le procédé électro-Fenton a démontré sa capacité à éliminer les pharmaceutiques et autres contaminants persistants. Ce procédé est basé sur la génération in-situ d'une espèce oxydante très puissante, les radicaux hydroxyles (OH), qui permettent la dégradation non-sélective des polluants. Cependant, cela nécessite l'utilisation d'une quantité d'énergie importante, relativement coûteuse. Une solution viable est de coupler le procédé électro-Fenton avec un procédé biologique. En effet, l'utilisation de ce dernier est beaucoup plus économique, mais il possède une efficacité limitée envers les polluants persistants tels que les pharmaceutiques. Ainsi, le procédé hybride bio-électro-Fenton apparaît comme un bon compromis entre le coût et l'efficacité. Le but de cette thèse de doctorat a donc été d'optimiser le procédé électro-Fenton dans l'optique de le coupler avec un procédé biologique, afin d'éliminer les pharmaceutiques. Les principaux objectifs de cette étude reposent sur l'étude de l'influence des paramètres opératoires utilisés au cours du procédé électro-Fenton sur (a) la dégradation des pharmaceutiques ; (b) la minéralisation de la matière organique ; (c) l'évolution de la biodégradabilité; (d) la consommation énergétique. Cette thèse est composée de trois parties, au cours desquelles la complexité des solutions traitées a progressivement augmentée. Premièrement, une étude a été menée sur des solutions de produits pharmaceutiques seuls afin de mieux comprendre les mécanismes impliqués au cours de leur dégradation. La seconde partie porte sur l'étude expérimentale d'une solution synthétique composée d'un mélange de 13 pharmaceutiques. La dernière étape a consisté à mettre en place un procédé bio-électro-Fenton pour le traitement d'un effluent pharmaceutique réel. Cette démarche progressive a permis de mieux comprendre l'influence des paramètres opératoires utilisés au cours du procédé électro-Fenton. Les principaux résultats obtenus sont notamment l'optimisation de deux paramètres opératoires important : la concentration du catalyseur (Fe2+) et l'intensité du courant. L'influence de ces paramètres s'est révélée similaires au cours du traitement de tous les types de solution testée. Il a donc été possible de conclure que les valeurs optimales sont une concentration en Fe2+ de 0,2 mM et une intensité entre 100 et 500 mA. L'efficacité d'élimination des pharmaceutiques a été plus importante en utilisant des intensités plus faibles (100-300 mA). Cependant, la biodégradabilité de l'effluent, un paramètre important dans l'optique du post-traitement biologique, a été d'avantage augmentée en utilisant des intensités élevées (500-1000 mA). Par ailleurs, l'utilisation d'intensités élevées a aussi mené à augmenter la consommation énergétique, en particulier dans le cas de temps de traitement longs. Il apparaît donc évident qu'un compromis entre efficacité et consommation énergétique doit être trouvé pour chaque cas particulier et effluent à traiter. Pour conclure, les avancées de cette recherche sont principalement attribuées à la nouveauté de la combinaison bio-électro-Fenton. L'étude de l'influence des paramètres opératoires du procédé électro-Fenton a aussi permis d'améliorer la compréhension de cette nouvelle technique et contribue à son développement vers une application industrielle / Water pollution is one of the biggest challenges that humanity faces and combating it requires the development of treatment processes, as conventional methods used nowadays are no longer effective for the removal of various complex pollutants. Recently pharmaceuticals have been recognized to be contaminants of emerging environmental concern as their traces were detected in a spectrum of water bodies around the globe. The long term effects of their presence in a natural environment are not yet fully studied, but the potential outcomes can be detrimental to a sustainable future. Among the variety of currently rising treatment technologies, the electro-Fenton method, an electrochemical advanced oxidation process, has demonstrated an ability to eliminate pharmaceuticals as well as other types of persistent contaminants. This electrocatalytical process generates in situ strong oxidants species - hydroxyl radical (OH) - which non-selectively degrade organic pollutants. Due to the extensive cost in the application of electrical energy, its operation might be cost-prohibitive. A solution would be to combine it with biological processes which are more economically viable, but also less effective in the removal of pharmaceuticals. The combined process is expected to have a synergetic effect between cost and effectiveness. The goal of this PhD thesis is to optimize operating conditions of the electro-Fenton process for a feasible combination with a biological process as a means of treating pharmaceutical pollution. The main objectives addressed by this work are related to the influence of operating parameters of the electro-Fenton process on (a) removal of pharmaceuticals; (b) mineralization of organic matter; (c) enhancement of biodegradability; (d) energy consumption. The thesis has three distinct parts related to the type of treated aqueous solution. First, a mechanistic study was conducted on aqueous solutions of individual pharmaceuticals in order to understand general trends of their removal. Next, a series of experiments was carried out on a synthetic mixture of thirteen pharmaceuticals from different therapeutic classes. Lastly, laboratory bench-scale reactors of a combined bio-electro-Fenton process were operated for the treatment of real wastewater. The advance in the complexity of the treated solution allowed a comprehensive comparison and analysis of the influence of the operating parameters. The main results include the optimal values of two operating parameters: the catalyst (Fe2+) concentration and the applied current intensity for a given electro-Fenton setup. The effects of the operating parameters on the removal of pharmaceuticals and other organic matter were similar regardless of the treated solution. The optimal value for the Fe2+ concentration was concluded to be around 0.2 mM. The optimal current intensity was in the range 100-500 mA. The efficiency of the current in terms of the pharmaceuticals' removal was the highest with the lowest intensity (100-300 mA). At the same time the biodegradability, which was an important factor in the biological post-treatment process, improved with higher intensities of electric current (500-1000 mA). However, high current intensities resulted in an elevated energy consumption, particularly with a prolonged treatment time. A tradeoff would have to be consequently made between energy saving and the removal rates that should be found in any single case. The novelty of the research presented in this PhD thesis is firstly attributed to the novelty of the combination of electro-Fenton to a biological process. A detailed study of the influence of operating parameters of the electro-Fenton process on removal rates and biodegradability enhancement contributed not only to the general knowledge on the electro-Fenton process, but also to the advancement towards its upscaling and then further towards the industrial application of this technique
94

Effet de l'aération d'appoint, de la saison et de l'espèce de macrophytes dans le traitement d'un effluent piscicole par marais artificiel

Ouellet-Plamondon, Claudiane January 2004 (has links)
No description available.
95

Automated Data Collection and Management at Enhanced Lagoons for Wastewater Treatment

Plana Puig, Queralt 23 April 2018 (has links)
Les stations de mesure automatiques sont utilisées pour suivre et contrôler des usines de traitement des eaux usées. Ce suivi en continu à haute fréquence est devenu indispensable afin de réduire les impacts négatifs sur l’environnement car les caractéristiques de l’eau varient rapidement dans l’espace et dans le temps. Toutefois, même s’il y a eu des progrès considérables, ces dernières années, de la technologie de mesure, les instruments sont encore chers. Aussi des problèmes de colmatage, d’encrassement ou de mauvaise calibration sont assez fréquents à cause du contact avec les eaux usées. La fiabilité des mesures en ligne et en continu est affectée négativement. Par conséquent, un bon entretien des instruments est essentiel, ainsi que la validation des données collectées, afin de détecter d’éventuelles valeurs aberrantes. Dans le contexte de ce mémoire, en collaboration avec Bionest®, une méthodologie est proposée pour attaquer ces problèmes. Deux cas d’études en étangs aérés au Québec ont été considérés, avec l’objectif d’optimiser les activités d’entretien, de réduire les données non fiables et d’obtenir des grandes séries de données représentatives. / Automated monitoring stations have been used to monitor and control wastewater treatment plants. Their capability to monitor at high frequency has become essential to reduce the negative impacts to the environment since the wastewater characteristics have an elevated spatial and time variability. Over the last few years, the technology used to build these automatic monitoring stations, for example the sensors, has been improved. However, the instrumentation is still expensive. Also, in wastewater uses, basic problems like fouling, bad calibration or clogging are frequently affecting the reliability of the continuous on-line measurements. Thus, a good maintenance of the instruments, as well as a validation of the collected data to detect faults is required. In the context of this thesis, in collaboration with Bionest®, a methodology has been developed to deal with these problems for two facultative/aerated lagoon case studies in Québec, with the objective of optimizing the maintenance activities, of reducing the fraction of unreliable data and of obtaining large representative data series.
96

Traitement biologique des effluents de serre par des marais filtrants artificiels et des bioréacteurs passifs

Gruyer, Nicolas 18 April 2018 (has links)
Lors de l'irrigation des cultures de tomate produites en serre, une partie importante de l'eau enrichie en engrais est rejetée dans l'environnement afin de contrôler la conductivité électrique du milieu de culture et l'équilibre ionique de la solution du sol. Plusieurs contraintes limitent la réutilisation de cette eau, par exemple une surcharge de l'eau en ions sulfates (SO₄²⁻) et la présence d'agents pathogènes, comme Pythium ultimum ou Fusarium oxysporum. Les objectifs de cette recherche étaient de (1) réduire les SO₄²⁻ en présence d'ions nitrates (NO₃⁻), (2) éliminer les agents pathogènes P. ultimum et F. oxysporum présents dans l'effluent de serre, (3) évaluer l'effet suppresseur de ces eaux traitées envers la pourriture pythienne, (4) comparer la croissance de plants de tomate irrigués avec les eaux traitées par les marais, (5) comprendre l'effet de différents amendements de C dans les marais filtrants sur la diversité métabolique et phylogénétique des populations microbiennes, et finalement (6) évaluer la capacité de bioréacteurs passifs à réduire les SO₄²⁻en présence d'ions NO₃⁻ , et à éliminer les agents pathogènes P. ultimum et F. oxysporum. Nos résultats ont démontré l'importance de la quantité et de la qualité de la source exogène de carbone (C) pour réduire les ions NO₃⁻ et SO₄²⁻. Pour un enlèvement optimal de SO₄²⁻et de NO₃⁻ (99 %), l'apport de C exogène doit atteindre les seuils C :N = 3,4 et COD: SO₄²⁻= 0,36. D'autre part, les marais filtrants ont été performants (99,99 %) à réduire les agents pathogènes P. ultimum et F. oxysporum, notamment par l'adsorption de ceux-ci au biofilm formé et par la production d'enzymes extracellulaires par les microorganismes. Le traitement des effluents par les marais confère également à l'eau des propriétés suppressives envers la pourriture pythienne. La quantité et la qualité du contenu en carbone utilisé pour amender les AWs ont eu une forte incidence sur l'activité métabolique des microorganismes pour l'utilisation des sources de N, P et S. Finalement, l'utilisation de bioréacteurs passifs a montré, par une activité microbienne importante, une efficacité similaire aux marais filtrants pour réduire les ions sulfates en présence de nitrates. De plus, les bioréacteurs passifs ont été aussi performants que les marais pour éliminer les agents pathogènes étudiés. L'utilisation des marais filtrants et des bioréacteurs constitue une alternative durable pour le traitement des effluents de serre.
97

Removal of nitrate from water and wastewater by ammonium-functionalized sba-16 mesoporous silica

Bui, Thi Hai Linh 19 April 2018 (has links)
La présence de composés azotés en excès peut conduire à la pollution de l'environnement et des problèmes de santé. Les ions nitrates sont les composés azotés les plus couramment rencontrés dans les eaux usées issues des activités humaines telles que l'agriculture. Par conséquent, l'élimination des ions nitrate dans les eaux souterraines et les eaux de surface ainsi que dans les eaux usées est d'une importance capitale. Actuellement, les principales méthodes appliquées pour l'élimination des ions nitrate, comprennent les méthodes biologiques et physico-chimiques. Cependant, ces traitements présentent des lacunes et des limites, telles que des conditions de réalisations coûteuses et complexes. Le procédé d'adsorption est considéré comme meilleur que les autres technologies de traitement des eaux usées, car sa conception est simple et son opération facile et économique, en plus de permettre de récupérer les ions nitrate. La technologie d'adsorption a été pratiquée avec succès dans l'élimination des ions nitrate avec divers matériaux comme adsorbants. Dans cette thèse, la silice mésoporeuse SBA-16 fonctionnalisée avec des groupements ammonium a été synthétisée et utilisée comme adsorbant potentiel pour l'élimination des ions nitrate dans l'eau potable et les eaux usées. Ceci est principalement dû à leur grande surface spécifique, leur méso-structure ordonnée et leur capacité de fonctionnalisation par différents groupes fonctionnels de surface. Le processus de fonctionnalisation de la SBA-16 avec des groupements amines (des groupes mono-, di- et tri-ammonium) peut être réalisé par deux méthodes: le procédé de greffage post-synthèse et par co-condensation. L'influence du pH de la solution, de la température d'adsorption, des ions compétitifs, de la charge en adsorbant et du rapport molaire organoalkoxysilane / silice a été étudiée par une série d'expériences d'adsorption en mode discontinu. Comme indiqué par les résultats de cette étude, la SBA-16 fonctionnalisée par greffage post-synthèse montre de meilleures performances en termes de pourcentage d'élimination des polluants et de capacité d'adsorption. La capacité d'adsorption maximale a été de 70,46 mg NO3-/ g d'adsorbant à une température de 5 ° C. Le processus d'adsorption a été très rapide et le temps d'équilibre a été atteint en moins de 5 minutes. La capacité d'adsorption a été augmentée en même temps la concentration initiale. L'enlèvement maximal pour les ions nitrate a été observé à pH 3 et au-delà de pH = 3, il n'y'a pas d'effet significatif sur cette élimination. La capacité d'adsorption augmente avec la modification du type d'amine, en passant du mono-, di - et tri-ammonium. En outre, les modèles d’adsorption tels que Freundlich, Temkin et Langmuir ont été appliqués aux isothermes obtenus. Les données d'équilibre d'adsorption sont en bon accord avec les modèles de Langmuir et de Temkin. De plus, les paramètres thermodynamiques ont été évalués pour le processus d'adsorption des ions nitrate. Les valeurs négatives des paramètres tels que l'enthalpie (AH °) et l'entropie (ΔSo) constatées pour l'ensemble des modèles d'isotherme, indiquent respectivement que la réaction est exothermique, et que la disposition aléatoire de l'adsorbat est en baisse à l'interface solide / liquide. / The presence of excess nitrogen (N) compounds can lead to environment pollutions and healthy problems. Also, nitrate ions are the commonly encountered N compounds in wastewater through human activities such as agriculture and human wastes. Therefore, removal of nitrate to diminish the concentration of nitrate in groundwater, surface water as well as in wastewaters is of prime importance. Normally, the major methods that have been applied for nitrate removal include biological and physicochemical technologies. However, current available treatments for nitrate removal have shortcomings and limitations such as high costs and complex operations. The adsorption process is considered better among other wastewater treatment technologies because of the simple design, easy and economical operation as well as allowing nitrate recovery. Adsorption technology has been found successful in nitrate removal by using various materials as adsorbents. In this thesis, ammonium-functionalized SBA-16 mesoporous silica was synthesized and used as potential adsorbent for nitrate removal in water and wastewater, which is due mainly to their large specific surface area, ordered meso-structure, and their functionalization ability by different surface functional groups. The functionalized SBA-16 process with amine groups (mono-, di- and tri ammonium silane) can be carried out through two methods: post synthesis grafting and co-condensation. The influence of solution pH, temperature, competitive ions, adsorbent loading and molar ratio organoalkoxysilane/silica was investigated by a series of batch adsorption experiments. As the results of this study, the mesoporous functionalized SBA-16 via post-synthesis grafting method exhibited higher performances in terms of percentage pollutant removal and adsorption capacities. The maximum adsorption capacity was found to be 70.46 mg NO3-/g adsorbent at temperature of 5oC. The adsorption was rapid at early stages of the treatment and the equilibrium was reached within 5 minutes. The capacity of adsorbent was increased with initial concentration. The maximum removal for nitrate was observed at pH of 3. The adsorption capacity increased with changing the amine type from mono-, di - to tri- ammonium silane groups. In addition, the parameters of adsorption process such as equilibrium adsorption isotherm and thermodynamic were investigated. The Freundlich, Langmuir and Temkin isotherm models were investigated. The adsorption equilibrium data were in good agreement with the Langmuir and Temkin isotherm models. The negative values of enthalpy (ΔH°) and entropy (ΔSo) were found for all of isotherm models. This indicates the exothermic character of nitrate adsorption process as well as the decrease in randomness at the solid/solution interface during the adsorption.
98

Étude de l'élimination des ions nitrate dans les effluents agroalimentaires au moyen d'un adsorbant organosilicate mésoporeux

Bouguerra, Maissa 17 April 2018 (has links)
Les ions nitrate présents dans les effluents agricoles et agroalimentaires sont la cause majeure de la pollution de l'eau induisant eutrophisation et risques sanitaires dûs à la méthémoglobinémie. Le traitement de ces effluents avant de les rejeter est alors impératif. De nombreux procédés biologiques et physicochimiques ont été mis en oeuvre pour le traitement de ces effluents. Cependant, l'adsorption s'avère une alternative prometteuse grâce à sa simplicité et sa rapidité. Dans le présent travail, l'objectif principal est l'étude du procédé d'adsorption des ions nitrate par un organosilicate mésoporeux de type SBA-15. Les essais ont été réalisés avec des solutions synthétiques en batch et analysés par HPLC ionique. Les matériaux ont été caractérisés par les techniques de DRX et BET. L'équilibre de l'adsorption a été modélisé par les modèles de Langmuir, Freundlich et Temkin afin de déterminer les paramètres thermodynamiques. La capacité d'adsorption maximale obtenue est de 50 mg/g. L'étude des conditions opératoires a révélé que le rendement d'adsorption augmente avec la charge en adsorbant et diminue avec la concentration initiale en nitrate. Le pH optimum est situé entre 4 et 8. Par ailleurs, l'étude de l'effet des ions S0₄²⁻, CO₃²⁻, Mg²⁺ et Ca²⁺ a montré que le sulfate et le carbonate ont un effet négatif sur l'adsorption. Les isothermes d'adsorption ont montré que la capacité d'adsorption diminue en augmentant la température. Aussi, le modèle de Langmuir s'applique le mieux aux résultats expérimentaux pour toutes les températures investiguées. L'adsorbant testé sur des solutions en présence de matière organique (acides phytiques et humiques) simulant les conditions réelles des effluents d'origine agricole nous a permis de conclure que la matière organique n'a pas d'effet significatif sur l'adsorption du nitrate.
99

Gestion intégrée des eaux usées urbaines : caractérisation et modélisation du comportement des polluants dans un bassin de rétention en réseau unitaire

Maruejouls, Thibaud 19 April 2018 (has links)
Si les débordements de réseaux unitaires sont reconnues comme étant un facteur important de l'impact environnemental du traitement des eaux usées urbaines, l'efficacité de l'implantation de bassins de rétention (BR) comme solution n'en demeure pas moins un questionnement. En effet, de plus en plus d'études tendent à prouver que l'impact de la vidange des BR sur l'efficacité de traitement d'une usine, et donc l'impact sur l'environnement, peut être négatif. L'interdisciplinarité et l'échelle géographique et temporelle de la problématique rendent l'appréhension de la problématique difficile par la seule mesure "in situ". L'intégration de plusieurs modèles du système urbain d'eaux usées se révèle être un outil puissant dans ce contexte. La simulation de différents scénarios amène à mieux anticiper les problèmes liés à la gestion des eaux usées, en temps de pluie comme en temps sec. Par conséquent, les coûts économiques et écologiques associés soit à la mise en place de nouvelles infrastructures, soit à la prise de décision concernant les stratégies de gestion du système, peuvent être optimisés. Il devient ainsi nécessaire de produire des modèles performants décrivant la qualité des eaux tout au long de leur cheminement. Les données sur le comportement des polluants dans les bassin de rétention sont peu nombreuses et la caractérisation des eaux retournées à l'usine de traitement est rarement étudiée. Par conséquent, si les connaissances des phénomènes en jeu sont souvent supposées, leur observation reste assez rare. Une partie importante du projet a donc été consacrée à la réalisation d'une campagne d'échantillonnage. Ce type d'échantillonnage s'est révélé être un exercice complexe et très contraignant en raison de l'imprévisibilité des événements orageux. L'objectif de cette campagne était de récolter des données en entrée et en sortie de bassin de rétention, principalement en ce qui concerne la matière en suspension, la demande chimique en oxygène et la distribution des vitesses de chute. Les résultats ont montré des dynamiques typiques de vidange révélant une forme en "U" des concentrations en polluants. Cette forme souligne trois phases appelées "initiale, milieu et finale" où chacune est caractérisée par une fourchette de concentrations et une distribution de vitesses de chute de particule qui lui est propre. De manière plus générale, il a été observé que plus les concentrations en MeS augmentent, plus la distribution des vitesses de chute est "lourde". Ces données couplées à des mesures en temps sec dans le collecteur et dans un bassin de décantation ont permis de comprendre les phénomènes en jeu, les interactions possibles entre les systèmes, et d'établir une structure solide pour le modèle. La littérature scientifique contient un grand nombre d'études de modélisation de la qualité de l'eau concernant les procédés de traitement. Cependant, elle est moins riche oncernant la description de la qualité des eaux en réseau et assez pauvre concernant la description de la qualité des eaux stockées en réseau ou en bassin de rétention. Les quelques modèles de BR existants décrivent assez simplement la décantation et la resuspension, qui sont pourtant les phénomènes dominant de ces systèmes. Ces modèles ont rarement été validés avec des données réelles car ces phénomènes sont difficiles à observer et à quantifier. Le projet visait donc à développer un modèle de bassin de rétention décrivant le comportement de la matière en suspension et de la demande chimique en oxygène à l'effluent d'un bassin de rétention (retour des eaux à l'usine) de sorte qu'il soit compatible avec les modèles de boue activées de type ASM de VInternational Water Association. La description des phénomènes de décantation et de resuspension est basée sur un fractionnement en classes de particules ayant différentes vitesses de chute. Ce fractionnement est directement issu de mesures de terrain réalisées en vue d'observer la variation de la distribution des vitesse de chute. Les effets d'un puits de pompage sur la sédimentation et la resuspension sont aussi décrits. Deux événements récoltés ont servi à la calibration du modèle et un autre a été utilisé pour sa validation. Cette étape est d'importance car elle n'a jamais été réalisée sur un modèle de BR. L'objectif final du modèle était qu'il soit intégré dans un système plus global (réseau - usine - rivière). Différents scénarios de gestion des vidanges de bassins de rétention ont mis en évidence les interactions entre les différents sous-systèmes en termes de masse de MeS et de masse de classes de particules. En effet, l'étude de l'évolution de la distribution des vitesses de chute des particules le long de la chaine de l'eau peut être une information utile pour anticiper les problèmes au traitement secondaire. Par exemple, une plus grande fraction de particules ayant une forte vitesse de chute peut engendrer : 1) une augmentation du temps d'hydrolyse des particules dans un système par boues activée ; ou 2) un plus grand risque de colmatage des biofiltres. Une meilleure compréhension de ces interactions peut permettre la mise en place de règles d'opération et de contrôle plus efficaces pour diminuer l'impact des rejets d'eaux usées sur l'environnement.
100

Diagnostic en place et prévision de l'évolution d'un système d'assainissement non collectif

Bouteldja, Fathe 12 October 2009 (has links) (PDF)
Les filières d'Assainissement Non Collectif (ANC) du fait de leur intérêt technique et économique connaissent un développement important. A ce jour, les gestionnaires de ce type d'ouvrages cherchent à mieux comprendre les phénomènes régissant leur fonctionnement et tentent ainsi d'améliorer cette filière sur le plan de la durabilité, de la fiabilité et de l'optimisation en s'appuyant sur des recommandations scientifiquement étayées auxquelles les études menées dans ce travail s'attachent à répondre. Les principaux objectifs industriels et scientifiques de cette thèse étaient de mieux comprendre le fonctionnement de ces sytèmes et de développer une méthodologie de diagnostic de leur état par la mise au point d'outils et de méthodes adaptés à ce genre d'onvrage. Nous avons proposé dans ce travail une démarche originale d'estimation de la perméabilité saturée ou non d'un sol in situ. Cette démarche est basée d'une part sur des informations de résistance et de granulométrie obtenues par couplage de mesures pénétrométriques et endoscopiques et d'autre part sur la connaissance de la relation résistance densité obtenue dans une base de données de matériaux. Cette démarche a été validée au laboratoire et utilisée in situ. Nous avons aussi proposé une méthodologie de diagnostic basée sur l'utilisation conjointe d'outils non destructifs et rapides à mettre en oeuvre à partir de différentes études réalisées in situ tant sur des ouvrages réels que sur des ouvrages expérimentaux grandeur nature.

Page generated in 0.0439 seconds