• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 40
  • 4
  • Tagged with
  • 44
  • 44
  • 18
  • 14
  • 13
  • 10
  • 9
  • 9
  • 9
  • 8
  • 8
  • 8
  • 8
  • 7
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Avaliação do potencial de utilização da macrófita aquática seca Salvinia sp. no tratamento de efluentes de fecularia / Evaluation of the potential use of dry aquatic macrophyte Salvinia sp. in an industrial cassava wastewater treatment

Limons, Rafaela da Silva 11 February 2008 (has links)
Made available in DSpace on 2017-07-10T18:08:09Z (GMT). No. of bitstreams: 1 Rafaela da Silva Limons.pdf: 1188810 bytes, checksum: 3222e9bb51995ce2bffdbb6505a56d20 (MD5) Previous issue date: 2008-02-11 / The industries of cassava processing are considered great polluting, therefore they generate highly pollutant a wastewater, the manipueira, with high concentration of organic substance. The method of treatment used in these industries is basically the system of stabilization. However, in function of the raised organic load, normally the effluent end if does not present in adequately favorable conditions for the ousting in hydrias resources, being essential a complementary treatment, so that the wastewater is adjusted to the current law. Thus, this work had for objective to study the removal of organic substance, nutrients and metals weighed, by means of a batelada system, for the dry biomass of the macrófita Salvinia sp. In this direction, with intention to investigate the factors that influence the capacity of removal of these contaminantes and to understand the mechanisms of this process, it was used as technique of factorial planning rotational central delineation composed - DCCR, verifying the influence of three independent 0 variable: pH initial, initial concentration of biomass - C and agitation -. The gotten results had shown that the best operational conditions had in accordance with varied the studied pollutant, thus best pH were: 5,8 for the match - P and zinc - Zn and 8,2 for the chemical demand of oxygen - DQO, nitrogen - N and have covered - Cu; the best concentration of biomass of 0,0013 g/mL for the DQO, the N, P and Zn and 0,0053 g/mL for the Cu and the 30 agitation of rpm for DQO and N and 120 rpm for the P, Zn and Cu. For the Compact disc removal of 100% in practically all was gotten the assays, in virtue of low the initial concentration of this metal. The gotten results had allowed to conclude respectively that in the best operational conditions the dry biomass of the Salvinia sp. influenced positively in process, reaching 97.91% of removal of DQO, 99.96% of P and 99.67% of N, with initial concentration of 20.480, 121,6 and 350 mg/L. Moreover, the results had shown to the promising character of the Salvinia sp. as biossorvente, being capable to adsorver up to 76,70% of íons of Zn, 99.79% of Cu and 100% of íons Compact disc, in industrias liquid residues contend small metal concentration heavy. The assays with the isotherms of adsorção of Zn and Cu had indicated that the capacity of biossorção of copper and 0,50 zinc had been approximately of 0,70 and meq/g in pH 5,0, being that the best adjustment occurred with the Isotherm of Sips. / As indústrias de processamento de mandioca são consideradas grandes poluidoras, pois geram um resíduo líquido altamente poluente, a manipueira, com alta concentração de matéria orgânica. O método de tratamento empregado nestas indústrias é basicamente o sistema de lagoas. Entretanto, em função da elevada carga orgânica, normalmente o efluente final não se apresenta em condições adequadamente favoráveis para o despejo em recursos hídricos, sendo essencial um tratamento complementar, para que o resíduo líquido esteja adequado à legislação vigente. Assim, este trabalho teve por objetivo estudar a remoção de matéria orgânica, nutrientes e metais pesados, por meio de um sistema batelada, pela biomassa seca da macrófita Salvinia sp. Neste sentido, com o intuito de investigar os fatores que influenciam a capacidade de remoção destes contaminantes e para se compreender os mecanismos deste processo, utilizou-se como técnica de planejamento fatorial o delineamento composto central rotacional - DCCR, verificando a influência de três variáveis independentes: pH inicial, concentração inicial de biomassa - C e agitação - A. Os resultados obtidos mostraram que as melhores condições operacionais variaram de acordo com o poluente estudado, assim o melhor pH foi: 5,8 para o fósforo - P e zinco - Zn e 8,2 para a demanda química de oxigênio - DQO, nitrogênio - N e cobre -Cu; a melhor concentração de biomassa de 0,0013 g/mL para a DQO, o N, P e Zn e 0,0053 g/mL para o Cu e a agitação de 30 rpm para a DQO e N e 120 rpm para o P, Zn e Cu. Para o Cd obteve-se remoção de 100% em praticamente todos os ensaios, em virtude da baixa concentração inicial deste metal. Os resultados obtidos permitiram concluir que nas melhores condições operacionais a biomassa seca da Salvinia sp. influenciou positivamente no processo, alcançando 97,91% de remoção de DQO, 99,96% de P e 99,67% de N, com concentração inicial de 20.480, 121,6 e 350 mg/L, respectivamente. Além disso, os resultados mostraram o caráter promissor da Salvinia sp. como biossorvente, sendo capaz de adsorver até 76,70% de íons de Zn, 99,79% de Cu e 100% de íons Cd, em resíduos líquidos industrias contendo pequena concentração de metais pesados. Os ensaios com as isotermas de adsorção de Zn e Cu indicaram que a capacidade de biossorção do cobre e zinco foram aproximadamente de 0,70 e 0,50 meq/g em pH 5,0, sendo que o melhor ajuste ocorreu com a Isoterma de Sips.
42

Estudo da redução de Cr(VI) usando espécies de macrófitas aquáticas vivas pela técnica de fluorescência de raios-X de alta resolução / Hexavalent chromium detoxification by living aquatic macrophites root-based biosorption using high resolution x-ray fluorescence

Martin, Neiva 08 October 2008 (has links)
Made available in DSpace on 2017-07-10T18:08:10Z (GMT). No. of bitstreams: 1 Neiva Martin.pdf: 2565426 bytes, checksum: 9ed40e36b9798ff30f3a52b416d705e9 (MD5) Previous issue date: 2008-10-08 / In this work, the chromium ions bioaccumulation experiment was carried out using three species of aquatic macrophytes: Salvinia auriculata, Pistia stratiotes and Eicchornia crassipes, in order to confirm the hexavalent chromium detoxification during the biosorption process. Previously, a chromium speciation test based on chemical extraction of trivalent chromium from hexavalent chromium-doped hydroponic solutions was also performed at different pH, in order to verify if the nutritive solution pH could be responsible by the natural reduction of oxidation state on chromium before the biosorption process by the plants. No reduction from Cr(VI) to Cr(III) was observed at all solution pH. Based on the peculiar characteristics of High Resolution X-ray Fluorescence technique (HR-XRF), which allows to measure the X-ray Kß spectral line energy with good energy resolution (around 2,0 eV) for the transition metal region, the change on oxidation state of hexavalent chromium was possible to study through the Kß1,3, Kß2,5 and Kß spectral lines, which bring up information on chromium oxidation state and chemical environment. The HR-XRF measurements were performed at the XRD1 vacuum chamber available in the National Laboratory of Synchrotron Light, located near Campinas city. After collection, dry roots and chromium compound standard were prepared in compact disk by pressing. Each sample disk, spherical curved analyzer, and radiation detector were placed in a circle of Rowland within an arrangement of Johann. Another radiation detector was also used to monitoring of monochromatic X-ray beam intensity during the measurements. All the samples were irradiated by a 6.1 keV monochromatic X-ray beam. All the emission spectra were normalized to the monitor counts, and subtracted the organic matrix contribution and chromium absorption edge. Based on the spectral Kß2,5 peak intensity of roots and standard samples, the total chromium uptake concentration in plant was calculated, indicating that there is approximately 1.0 % of chromium per dry biomass after 27 days of experiment. When both Cr-Kß spectra of macrophytes roots with Cr(III) and Cr(VI) treatment were compared, their spectral Kß2,5 peak were identical in energy and width for the three aquatic plants, suggesting that the chromium reduction from hexavalent to trivalent form have occurred in all cases studied. The peak width at half maximum for Kß2,5 in all root samples were slightly larger than the chromium compound samples, which can be explained by the fact that there is the possibility to have different ligands to chromium ions inside the biological structure of roots. Based on these results, the chromium detoxification from hexavalent to trivalent form have actually happened during the biosorption of chromium into the macrophytes roots. Finally, these aquatic macrophytes have a great potential to detoxificate and accumulate of chromium ions that can be very useful to the metal removal from industrial effluents. / Neste trabalho foi feito o experimento de bioacumulação do cromo trivalente e hexavalente por três espécies de macrófitas aquáticas: Salvinia auriculata, Pistia stratiotes e Eicchornia crassipes, visando verificar a ocorrência do processo de redução do Cr(VI) durante a biossorção. Previamente, um teste de especiação de cromo baseado em extração química do cromo trivalente a partir de uma solução hidropônica dopada com cromo hexavalente, foi realizado em diferentes pHs, para verificar se o pH da solução nutritiva pode ser o responsável pela redução natural do estado de oxidação do cromo antes do processo de biossorção pelas plantas. Não foi observada a redução do Cr(VI) para Cr(III) no pH da solução de cultivo. Pelas características da técnica de Fluorescência de Raios-X de Alta Resolução em Energia (HR-XRF), que permite medir a energia das linhas espectrais de raios X Kß com alta resolução em energia (em torno de 2,0 eV) para a região dos metais de transição, foi possível estudar a mudança do estado de oxidação do cromo hexavalente através das linhas espectrais Kß1,3, Kß2,5 e Kß , que traz informação sobre o estado de oxidação do metal e seu ambiente químico. As medidas de HR-XRF foram realizadas na câmara de vácuo XRD1, no Laboratório Nacional de Luz Síncrotron, em Campinas. Após a coleta, discos compactados de raízes secas e padrões de compostos de cromo foram preparados. Cada disco de amostra, o analisador esférico, e o detector de radiação foram acomodados em um círculo de Rowland com arranjo de Johann. Durante as medidas, um detector foi usado para monitorar a intensidade do feixe de raios X monocromáticos incidentes. Todas as amostras foram irradiadas com feixe monocromático de 6,1 keV. Os espectros de emissão foram normalizados pelas contagens do monitor, e subtraída as contribuições da matriz orgânica e da borda de absorção do cromo. Baseado na intensidade da linha espectral Kβ2,5 das amostras de raízes e padrões, a concentração de cromo total nas plantas foi calculada, indicando que esta é de aproximadamente 1,0% por biomassa seca após 27 dias de experimento. Os espectros de emissão Cr-Kß das raízes das macrófitas tratadas com Cr(III) ou Cr(VI) foram comparados, e as suas linhas espectrais Kβ2,5 mostraram-se idênticas em energia e largura para as três plantas aquáticas, sugerindo que a redução do cromo, de hexavalente para trivalente, ocorreu em todos os casos estudados. A largura do pico para a linha espectral Kß2,5 em todas as amostras de raízes mostrou-se maior que nas amostras de compostos de cromo, o que pode ser explicado pelo fato de que é possível haver diferentes ligantes para o íon cromo na estrutura orgânica das raízes. Baseado nesses resultados, a redução do Cr(VI) para Cr(III) ocorreu durante o processo de biossorção do cromo pelas raízes das macrófitas aquáticas. Desta forma, verifica-se que estas macrófitas têm um grande potencial para detoxificar e acumular íons cromo, podendo ser utilizada com eficiência na remoção de metais em efluentes industriais.
43

Aplicação dos processos foto-Fenton e eletrofloculação no tratamento de efluente de curtume / Application of the photo-Fenton and electrocoagulation processes at the tannery effluent treatment

Borba, Fernando Henrique 18 February 2010 (has links)
Made available in DSpace on 2017-07-10T18:08:12Z (GMT). No. of bitstreams: 1 Fernando Henrique Borba.pdf: 3301834 bytes, checksum: 0c5216d667957cc99d5acd2dd5d59c05 (MD5) Previous issue date: 2010-02-18 / Pollution is a currently environmental problem of world concern. There are many events such as the discharging of untreated effluents in watercourses that cause the eutrophization of water bodies and bad water quality, as well as an inefficiency or lack of a current environmental law. The main goal of this dissertation was the application of solar and artificial-based photo-Fenton processes and aluminum electrodes-based electrocoagulation method in non coupled mode and in an integrated mode for the tannery effluent treatment. These effluent treatments were carried out in lab-scale reactors. In order to evaluate the performance of the reactor experimental conditions of photo-Fenton reactor, a 33 complete experimental design was performed. The lab scale EC reactor was operated at the 4 A electrical current, 4 cm electrode distance and 3 initial pH optimized values, according to the previous results obtained in another work, while the electrolysis time was varied from 5 to 120 min. For EC and photo-Fenton reactors, their performance was evaluated on the removal values of chemical oxygem demand (COD), color, turbidity, total solids (TS), total fixed solids (TFS), total volatile solids (TVS) and metal concentration. Measurements of physico-chemical parameters for untreated and treated effluent samples were performed applying the Standard Method for water analysis, while metal concentrations were determined by the Synchrotron radiation total Reflexion X-ray Fluorescence technique at Brazilian Light Synchrotron Laboratory. By an optimized photon-Fenton process at 0.5 g Fe2+ L-1, 30 g H2O2 L-1, 3 initial pH, and 120 min reaction time, tannery effluent was treated achieving a high performance in pollutant removal as reported by 98.1, 96.4, 98.8, 71.8, 32.1 and 98.5 percent removal for COD, color, turbidity, TS, TFS, and TVS, respectively. As a primer treatment stage, electrocoagulation technique was not achieved a well successful result based on the physico-chemical parameter values reduction as compared with photo-Fenton process. However, an integrated solar irradiation-based photo-Fenton and Al electrodes-based electrocoagulation with 15 min electrolysis time has achieved recommended values by the Brazilian environmental law for Cr concentration (0.24 mg Cr L-1) and DQO (107 mg O2 L-1). Considering both the costs of electrical energy and material and the generated sludge discharging, one m3 of tannery effluent should cost R$ 56.30 for a treatment system based on an integrated and optimized photo Fenton and electrocoagulation processes. Finally, the integrated solar-based photo Fenton and electrocoagulation method is suggested as an efficient one, instead to apply a unique process. / A poluição ambiental é um dos grandes problemas nos países desenvolvidos e em desenvolvimento. Isto é decorrente de uma série de fatores, como o despejo de efluentes não tratados em corpos hídricos e a ineficiência e/ou a falta de legislação ambiental vigente. O objetivo principal deste trabalho é aplicar os processos foto-Fenton com irradiação solar e/ou artificial, a técnica da eletrofloculação e a integração destes processos no tratamento de efluente de curtume. Ambos os processos de tratamento do foto-Fenton e da eletrofloculação foram conduzidos em reatores a escala laboratorial. Para a técnica da eletrofloculação foi utilizado um par de placas de alumínio como eletrodos no reator de eletrofloculação. Para avaliar as melhores condições de processo do sistema foto-Fenton, foi aplicado um planejamento experimental 33 completo. Para a técnica da eletrofloculação manteve-se constante a intensidade de corrente, pH inicial do efluente bruto e distância entre os eletrodos, variando-se o tempo de eletrólise de 5 à 120 min. A eficiência de ambos os processos foram avaliadas com base na redução de Demanda química de oxigênio (DQO), cor, turbidez, sólidos totais (ST), sólidos totais fixos (STF), sólidos totais voláteis (STV). Para a técnica da eletrofloculação e dos processos integrados também foram avaliados a redução da concentração dos metais pesados. Todas as medidas dos parâmetros físico-químicos foram realizadas aplicando os métodos padrões do Standard Methods for the Examination of Water and Wastewater para amostra não tratada e tratada. As concentrações dos metais pesados foram determinadas usando a técnica de fluorescência de raio X por reflexão total, na linha de Luz (D09-XRF) do Laboratório Nacional de Luz Synchrotron. A maior eficiência na redução dos poluentes verificada no processo foto-Fenton foi de 98,1, 96,4, 98,8, 71,8, 32,1 e 98,5 para valores da DQO, cor, turbidez, ST, STF e STV, respectivamente, nas condições operacionais do reator: concentração de ferro de 0,5 gL-1, concentração de peróxido de hidrogênio de 30 gL-1, pH inicial 3 e tempo reacional de 120 min. No entanto a técnica da eletrofloculação não apresentou boa redução nos valores dos parâmetros físico-químicos. Após a aplicação dos processos integrados do foto-Fenton com irradiação solar e da eletrofloculação em tempo de eletrólise de 15 min, foi alcançado valores mínimos de Cr e DQO no efluente tratado, contendo 0,24 mg Cr L-1 e 107 mg O2 L-1 da DQO. O custo do tratamento do efluente e da disposição final do lodo gerado no processo integrado FFs→EF foi de R$ 56,30 m3 do efluente de curtume tratado. Este processo integrado reduziu as concentrações de cromo, ferro e DQO, a níveis permitidos pelas legislações ambientais. Baseada na redução da matéria orgânica e inorgânica, o método integrado FFs→EF pode ser recomendado como uma substituição eficiente ao método individual.
44

Tratamento de efluente têxtil utilizando o processo foto-fenton / Treatment of textile effluent using photo-fenton process

Manenti, Diego Ricieri 25 February 2011 (has links)
Made available in DSpace on 2017-07-10T18:08:15Z (GMT). No. of bitstreams: 1 Diego Ricieri Manenti.pdf: 2926963 bytes, checksum: 74aa89bdde44c5ef6942846129864678 (MD5) Previous issue date: 2011-02-25 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The aim of this work was to study the performance of the photo-Fenton process using both the artificial UV and solar sources on the textile effluent treatments. Preliminary photo-Fenton experiments for mineralization and degradation of organic and inorganic pollutants as well as of synthetic dyes were carried out in order to assess the best experimental conditions by photo-Fenton process. As synthetic textile effluent a mixture of six dyes: Solophenyl orange TGL (C25H33ClN6O6S2), Solophenyl blue 71 (C40H23N7Na4O13S4), Solophenyl scarlet BNLE (C44H32N10Na4O16S4), Solophenyl yellow ARL (C48H26N8Na6O18S6), Solophenyl black FR (C44H32N13Na3O11S3) e Navy Blue 98 (C38H24N5Na3O13S3) that contained 50 mg L-1 concentration was prepared and diluted in distillated water. The photo-Fenton experiments by using a set of high-pressure mercury lamps and solar light as artificial and natural UV irradiation sources were performed in laboratory scale. As reactor operational parameters to be optimized by a 33 full factorial experimental design: hydrogen peroxide and divalent iron ion as well as the initial solution pH were chosen as variables, keeping constant a reaction time of 120 min that was enough to warrant the maximum (chemical oxygen demand) COD and color removal. The efficiency of photo-Fenton process applied in the treatment of synthetic and real effluents, was evaluated based on the parameters: values of COD, color, turbidity, total organic carbon (TOC), absorbance at a wavelength of maximum absorption for the dyes and simple aromatic compounds and conjugated reductions, as well as behavior analysis of the evolution the sulfate, nitrate inorganic, organic nitrogen and ammonia concentrations. Second-degree models for the COD and color removal percents were proposed to model the photo-Fenton experiments data in order to reduce the cost of running such a photo-Fenton experiment as well as to obtain optimum values of the reactor operating parameters. Second-degree models were also validated by ANOVA. Predicted yields showed good validation with experimental yields. The values of the optimized reactor operational parameters were 3.0, 6.0 g L-1, and 0.05 g L-1 for initial pH, hydrogen peroxide and divalent iron concentrations, respectively, for both photo-Fenton processes. Based on this optimized experimental conditions, almost 100% removals of physico-chemical parameter such as COD, color, turbidity and COT for real textile effluents. The aromatics compounds were showed more resistant to reaction, persisting for longer. It can be noticed that the degradtion of the organic and inorganic matters were verified by the nitrification process and, the sulfates formation and reduction. The process presented similar efficiencies with both solar and artificial irradiation, thus suggesting the use of solar photo-Fenton, as it proved to be an efficient alternative besides using a source of clean and renewable energy. / O objetivo deste trabalho é avaliar o desempenho do processo foto-Fenton, utilizando energia solar e artificial como fontes de irradiação UV, no tratamento de efluentes têxteis. Foram realizados experimentos preliminares para avaliar a eficiência do processo foto-Fenton na mineralização e degradação dos poluentes orgânicos e inorgânicos, bem como dos corantes sintéticos. Para tanto, foi preparado o efluente têxtil sintético pela mistura de seis corantes: Laranja TGL (C25H33ClN6O6S2), Azul FGLE (C40H23N7Na4O13S4), Escarlate BNLE (C44H32N10Na4O16S4), Amarelo ARLE (C48H26N8Na6O18S6), Preto FR (C44H32N13Na3O11S3) e Marinho BLE (C38H24N5Na3O13S3), em água destilada, com concentração de 50 mg L-1. Os experimentos foram realizados em reatores de escala laboratorial utilizando fontes de irradiação UV natural e artificial. Os parâmetros operacionais dos reatores: pH inicial e a concentração dos reagentes H2O2 e Fe2+, foram otimizados baseados nos valores da demanda química de oxigênio (DQO) e descoloração, a partir de um planejamento fatorial 33 completo com o tempo de irradiação constante em 120 minutos. A eficiência do processo foto-Fenton, aplicado no tratamento dos efluentes sintético e real, foi avaliada baseada nos parâmetros: redução dos valores da DQO, cor, turbidez, carbono orgânico total (COT), absorvância nos comprimentos de onda de máxima absorção relativos aos corantes e aos compostos aromáticos simples e conjugados, além da análise do comportamento da evolução das concentrações de sulfato, nitrato inorgânico, nitrogênio orgânico e amoniacal. Para auxiliar na obtenção das condições ótimas dos parâmetros operacionais do reator e redução dos custos do processo foto-Fenton, as respostas experimentais para a redução da DQO e da cor foram ajustados por um modelo previsto de segunda ordem, o qual apresentou uma boa modelagem dos dados, validado pela ANOVA. Os valores ótimos operacionais do reator, para ambos os processos foto-Fenton no tratamento do efluente real, foram: pH = 3,0, concentração de H2O2 = 6,0 g L-1 e concentração de Fe2+ = 0,05 g L-1. Nestas condições, foram obtidos valores próximos a 100% de redução dos parâmetros físico-químicos DQO, cor, turbidez e COT. Os compostos aromáticos se mostraram mais resistentes a reação, persistindo por mais tempo. A degradação da matéria orgânica e inorgânica foi verificada analisando a evolução do processo de nitrificação e a formação ou redução de sulfatos. Os processos apresentaram eficiências similares tanto com irradiação solar como artificial, desta forma, sugere-se a utilização do processo foto-Fenton solar, pois mostrou ser uma alternativa eficiente além de utilizar uma fonte de energia limpa e renovável.

Page generated in 0.1163 seconds