• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 27
  • Tagged with
  • 27
  • 27
  • 14
  • 12
  • 11
  • 8
  • 8
  • 8
  • 7
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Correlação estrutura-propriedades de silicones para prótese facial - Efeitos da pigmentação e do envelhecimento / Correlation structure-properties of silicones for facial prosthesis - Effects of pigmentation and aging

Pinheiro, Juliana Barchelli 13 April 2012 (has links)
Este estudo avaliou a dureza Shore A, alteração de cor, recuperação elástica e resistência ao rasgamento de um silicone experimental (Ortho Pauher - O), quando comparado a um silicone usado em reabilitações faciais (MDX 4-4210 - MDX), quando submetidos à pigmentação e envelhecimento e ainda, analisou a micro estrutura desses materiais. Para análise da alteração de cor e dureza foram obtidos 160 espécimes circulares (80/material); para os ensaios de recuperação elástica foram obtidos 200 espécimes cilíndricos (100/material) e para o ensaio de resistência ao rasgamento, foram confeccionados 200 espécimes em forma de calça (100/material). Metade dos espécimes recebeu pigmentação intrínseca e a outra metade, pigmentação intrínseca e extrínseca, por meio da adição de pó de maquiagem. Em seguida, foram distribuídos aleatoriamente em três grupos de envelhecimento: 1 termociclagem (T), 2 - luz ultravioleta (UV) e 3 - luz natural (LN). O envelhecimento simulou um período de uso de um ano. Como controle (C), os espécimes foram mantidos em um recipiente fechado e na ausência total de luz por um ano. Para as análises micro estruturais, três espécimes de cada grupo foram submetidos à Microscopia Eletrônica de Varredura (MEV), Espectroscopia no Infravermelho (EI), Calorimetria Exploratória Diferencial (DSC) e Termogravimetria (TG). Os dados foram submetidos à Análise de variância e Teste Complementar de Tukey (p<0,05). Os resultados das análises micro estruturais foram apresentados em tabelas e gráficos. Para alteração de cor, não houve diferença entre os materiais e pigmentação. Os envelhecimentos por UV, LN e T promoveram a maior alteração. O MDX apresentou alterações em função da PIE, T e UV e o Ortho Pauher, em função da PI/UV e PIE/T e UV. Para a dureza, o silicone Ortho e a PI apresentaram as maiores alterações, bem como a LN e a UV. Ambos os materiais variaram em função das pigmentações e envelhecimento. Para resistência ao rasgamento houve diferença para todos os fatores e para a interação. O silicone O e a PI promoveram as menores médias. O MDX sofreu alteração em função da pigmentação e do envelhecimento. Na recuperação elástica, o material M apresentou a maior média, bem como o grupo PIE. Para o envelhecimento, a UV resultou em menor recuperação e os maiores valores foram encontrados no C e LN. Os dois materiais variaram em função da pigmentação e envelhecimento. As análises micro estruturais demonstraram que a polimerização dos materiais foi completa e que os pigmentos adicionados, nas proporções utilizadas, não influenciaram na estabilidade dos materiais. O resultado do estudo sugere que as alterações encontradas nas propriedades físico-mecânicas, em função da exposição às diferentes pigmentações e envelhecimento não representam diferenças estruturais importantes e que o silicone experimental merece estudos com vistas em sua aplicabilidade clínica e que o silicone experimental precisa ser estudado com vistas em sua aplicabilidade clínica. / This study evaluated the color change, Shore A hardness, tear resistance and elastic recovery of an experimental silicone (Ortho Pauher - O), compared to a silicone used in facial rehabilitation (MDX 4-4210 - MDX), when submitted to pigmentation and accelerated aging and also examined the microstructure of these materials. To analyze the color change and hardness, we were obtained 160 circular specimens (80/material); for the elastic recovery, 200 cylindrical specimens were obtained (100/material) and for the tear strength, 200 specimens were fabricated in the form of pants (100/material). Half of the samples received intrinsic pigmentation and the other half received intrinsic and extrinsic pigmentation, also by applying makeup powder. Subsequently, the specimens were randomly distributed into three groups of aging: 1 - thermocycling (T), 2 - ultraviolet light (UV) and 3 - natural light (NL). All of the aging steps simulated a period of 1-year. As a control (C), the specimens were kept in a closed container in total absence of light for 1-year. For the micro structural analysis, three specimens of each group were subjected to Scanning Electron Microscopy (SEM), Infrared Spectroscopy (EI), Differential Scanning Calorimetry (DSC) and Thermogravimetry (TG). For statistical analysis tests were used ANOVA and Tukeys test (p<0.05). For the micro structural analysis, the results were presented in tables and graphs. For color change, there was no difference between the materials and pigmentation. The UV, LN and T aging, promoted the greatest change. MDX was altered in function of the IEP, T and UV and Ortho Pauher, according to the PI/UV and IEP/T and UV. For hardness, Ortho Pauher silicone and IP showed the greatest changes, as well as the LN and UV. Both materials varied depending on the pigmentation and aging. For tear strength, difference was found for all factors and interaction. The Silicone Ortho Pauher and IP promoted the lowest averages. The MDX was altered depending of the pigmentation and aging. In the elastic recovery, the material M and the PIE group showed the highest average. For aging, UV resulted in lower recovery and higher values were found in the C and LN. The two materials were changed according to pigmentation and aging. The micro structural analyzes showed that the polymerization was completed and the material and the pigments added, in the proportions used, do not influence the stability of the materials. The study results suggest that the changes found in physical-mechanical properties, depending on exposure to different pigmentation and aging, do not represent important structural alterations and the experimental silicone needs to be studied with a view to its clinical applicability.
12

Correlação estrutura-propriedades de silicones para prótese facial - Efeitos da pigmentação e do envelhecimento / Correlation structure-properties of silicones for facial prosthesis - Effects of pigmentation and aging

Juliana Barchelli Pinheiro 13 April 2012 (has links)
Este estudo avaliou a dureza Shore A, alteração de cor, recuperação elástica e resistência ao rasgamento de um silicone experimental (Ortho Pauher - O), quando comparado a um silicone usado em reabilitações faciais (MDX 4-4210 - MDX), quando submetidos à pigmentação e envelhecimento e ainda, analisou a micro estrutura desses materiais. Para análise da alteração de cor e dureza foram obtidos 160 espécimes circulares (80/material); para os ensaios de recuperação elástica foram obtidos 200 espécimes cilíndricos (100/material) e para o ensaio de resistência ao rasgamento, foram confeccionados 200 espécimes em forma de calça (100/material). Metade dos espécimes recebeu pigmentação intrínseca e a outra metade, pigmentação intrínseca e extrínseca, por meio da adição de pó de maquiagem. Em seguida, foram distribuídos aleatoriamente em três grupos de envelhecimento: 1 termociclagem (T), 2 - luz ultravioleta (UV) e 3 - luz natural (LN). O envelhecimento simulou um período de uso de um ano. Como controle (C), os espécimes foram mantidos em um recipiente fechado e na ausência total de luz por um ano. Para as análises micro estruturais, três espécimes de cada grupo foram submetidos à Microscopia Eletrônica de Varredura (MEV), Espectroscopia no Infravermelho (EI), Calorimetria Exploratória Diferencial (DSC) e Termogravimetria (TG). Os dados foram submetidos à Análise de variância e Teste Complementar de Tukey (p<0,05). Os resultados das análises micro estruturais foram apresentados em tabelas e gráficos. Para alteração de cor, não houve diferença entre os materiais e pigmentação. Os envelhecimentos por UV, LN e T promoveram a maior alteração. O MDX apresentou alterações em função da PIE, T e UV e o Ortho Pauher, em função da PI/UV e PIE/T e UV. Para a dureza, o silicone Ortho e a PI apresentaram as maiores alterações, bem como a LN e a UV. Ambos os materiais variaram em função das pigmentações e envelhecimento. Para resistência ao rasgamento houve diferença para todos os fatores e para a interação. O silicone O e a PI promoveram as menores médias. O MDX sofreu alteração em função da pigmentação e do envelhecimento. Na recuperação elástica, o material M apresentou a maior média, bem como o grupo PIE. Para o envelhecimento, a UV resultou em menor recuperação e os maiores valores foram encontrados no C e LN. Os dois materiais variaram em função da pigmentação e envelhecimento. As análises micro estruturais demonstraram que a polimerização dos materiais foi completa e que os pigmentos adicionados, nas proporções utilizadas, não influenciaram na estabilidade dos materiais. O resultado do estudo sugere que as alterações encontradas nas propriedades físico-mecânicas, em função da exposição às diferentes pigmentações e envelhecimento não representam diferenças estruturais importantes e que o silicone experimental merece estudos com vistas em sua aplicabilidade clínica e que o silicone experimental precisa ser estudado com vistas em sua aplicabilidade clínica. / This study evaluated the color change, Shore A hardness, tear resistance and elastic recovery of an experimental silicone (Ortho Pauher - O), compared to a silicone used in facial rehabilitation (MDX 4-4210 - MDX), when submitted to pigmentation and accelerated aging and also examined the microstructure of these materials. To analyze the color change and hardness, we were obtained 160 circular specimens (80/material); for the elastic recovery, 200 cylindrical specimens were obtained (100/material) and for the tear strength, 200 specimens were fabricated in the form of pants (100/material). Half of the samples received intrinsic pigmentation and the other half received intrinsic and extrinsic pigmentation, also by applying makeup powder. Subsequently, the specimens were randomly distributed into three groups of aging: 1 - thermocycling (T), 2 - ultraviolet light (UV) and 3 - natural light (NL). All of the aging steps simulated a period of 1-year. As a control (C), the specimens were kept in a closed container in total absence of light for 1-year. For the micro structural analysis, three specimens of each group were subjected to Scanning Electron Microscopy (SEM), Infrared Spectroscopy (EI), Differential Scanning Calorimetry (DSC) and Thermogravimetry (TG). For statistical analysis tests were used ANOVA and Tukeys test (p<0.05). For the micro structural analysis, the results were presented in tables and graphs. For color change, there was no difference between the materials and pigmentation. The UV, LN and T aging, promoted the greatest change. MDX was altered in function of the IEP, T and UV and Ortho Pauher, according to the PI/UV and IEP/T and UV. For hardness, Ortho Pauher silicone and IP showed the greatest changes, as well as the LN and UV. Both materials varied depending on the pigmentation and aging. For tear strength, difference was found for all factors and interaction. The Silicone Ortho Pauher and IP promoted the lowest averages. The MDX was altered depending of the pigmentation and aging. In the elastic recovery, the material M and the PIE group showed the highest average. For aging, UV resulted in lower recovery and higher values were found in the C and LN. The two materials were changed according to pigmentation and aging. The micro structural analyzes showed that the polymerization was completed and the material and the pigments added, in the proportions used, do not influence the stability of the materials. The study results suggest that the changes found in physical-mechanical properties, depending on exposure to different pigmentation and aging, do not represent important structural alterations and the experimental silicone needs to be studied with a view to its clinical applicability.
13

Avaliação de implantes mamários distribuídos no mercado Brasileiro. / Évaluation des implants mammaires distribués sur le marché brésilien. / Evaluation of breast implants distributed in the Brazilian market. / Evaluación de implantes mamarios distribuidos en el mercado brasileño.

PEREIRA, Leandro Rodrigues. 10 April 2018 (has links)
Submitted by Johnny Rodrigues (johnnyrodrigues@ufcg.edu.br) on 2018-04-10T19:06:53Z No. of bitstreams: 1 LEANDRO RODRIGUES PEREIRA - DISSERTAÇÃO PPG-CEMat 2014..pdf: 3148791 bytes, checksum: 14fe302e950234a170c84cd8636b58ad (MD5) / Made available in DSpace on 2018-04-10T19:06:53Z (GMT). No. of bitstreams: 1 LEANDRO RODRIGUES PEREIRA - DISSERTAÇÃO PPG-CEMat 2014..pdf: 3148791 bytes, checksum: 14fe302e950234a170c84cd8636b58ad (MD5) Previous issue date: 2014-07-17 / Desde o final do século XIX, foram utilizados vários materiais para o aumento da mama. Como exemplos, citam-se espumas de poliuretano e polietileno, bolas de vidro, gutta percha, entre outros. O uso de silicone para fins de aumento de mama se iniciou em 1961 e, partir de então, as empresas desenvolveram inovações ao processo de fabricação de implantes mamários incluindo a inserção de camadas de barreiras para evitar a migração de gel. Em 2012, foi publicada a Resolução ANVISA RDC nº 16 que estabeleceu os requisitos mínimos de identidade e qualidade para os implantes mamários de silicone. Desta forma, este trabalho propõe a avaliar os implantes mamários regularizados no Brasil e realizar a caracterização morfológica, estrutural e mecânica de implantes mamários de silicone comercializados no Brasil em conformidade com as Normas Vigentes, por meio de caracterizações: Microscopia Ótica – MO, Microscopia Eletrônica de Varredura – MEV com espectroscopia de Energia Dispersiva- EDS e avaliação do comportamento mecânico quando submetidos ao Ensaio de Tração, sendo avaliados os quesitos estabelecidos na norma ISO 14607:2007. Com base nos resultados obtidos neste trabalho pode-se concluir que todas as membranas de implantes mamários avaliadas apresentaram-se adequadas para uso como biomaterial. Verificou-se também a oportunidade de melhoria normativa, com estabelecimento de parâmetro mínimo de desempenho para o ensaio de resistência ao rasgo, estabelecido na norma ISO 14607:2007. / Since the late nineteenth century, various materials were used for breast augmentation. Polyurethane, polyethylene, glass balls, gutta percha, among others materials were used. The use of silicone for breast augmentation purposes began in 1961 and, since then, companies have developed innovations to the manufacturing process of breast implants including the insertion of barrier layers to prevent migration of silicone gel. In 2012 was published the ANVISA Resolution RDC No. 16 which established minimum requirements for identity and quality for silicone breast implants. Thus, this study aims to evaluate six brands of regularized breast implants in Brazil and perform morphological, structural and mechanical caracterization in accordance with current standards. Optical Microscopy - MO, Electron Microscopy Scanning - SEM with Energy Dispersive Spectroscopy- EDS and evaluation of the mechanical behavior when subjected to tensile test according to ISO 14607:2007 standard. Based on the results obtained in this study, it can be concluded that all the membranes of breast implants had to be suitable for use as a biomaterial, complying with regulatory requirements. There is also an opportunity to improve the ISO 14607:2007 standard, establishing a minimum performance requirement for testing elastomer shell tear resistance.
14

Avaliação dos elásticos ortodônticos intra-orais de látex e de borracha sintética: estudo in vitro e in vivo / Evaluation of orthodontic intraoral latex elastic and synthetic rubber: study in vitro and in vivo

Daniela Ferreira de Carvalho Notaroberto 25 February 2014 (has links)
Os elásticos ortodônticos intermaxilares sintéticos vem sendo cada vez mais utilizados, sendo principalmente indicados para pacientes que apresentam hiper-sensibilidade ao látex. Afim de avaliar e comparar o comportamento de elásticos de látex e sintéticos quanto a perda de força ao longo do tempo, este estudo foi realizado tanto in vitro quanto in vivo. Para o estudo in vitro foram avaliados 15 elásticos de cada material, para cada tempo: 0, 1, 3, 12 e 24 horas. No estudo in vivo, pacientes foram avaliados (N=15), utilizando elásticos de ambos os materiais (látex e sintético), nos mesmos tempos do estudo in vitro. Os elásticos foram transferidos para a máquina de ensaios mecânicos (EMIC DL-500 MF). Os valores da força gerada foram registrados após a distensão dos elásticos a uma distância de 25mm. Foi aplicado o teste t pareado para a amostra clínica e independente para a amostra laboratorial. Foi utilizada a análise de variância (ANOVA) para verificar a variação das forças geradas entre os tempos determinados e o teste post-hoc para identificar entre quais tempos houve diferença significativa. Quanto às forças iniciais geradas (zero hora), os valores para os elásticos sintéticos foram bastante semelhantes entre os estudos laboratorial e clínico e ligeiramente superiores aos dos elásticos de látex. Nos tempos subsequentes, as forças geradas pelos elásticos de látex apresentaram valores superiores. Em relação à degradação do material, ao final de 24 horas, maior percentual foi observado para os elásticos sintéticos, tanto in vitro quanto in vivo. A maior queda nos valores das forças liberadas pelos elásticos de ambos os materiais e nos estudos clínico e laboratorial, ocorreu entre os tempos de 0 e 1 hora, seguida de uma queda gradativa e progressiva até o tempo de 24 horas. Os elásticos de látex apresentaram um comportamento mais estável no período estudado em relação aos sintéticos, em ambos os estudos. / Synthetic intermaxillary orthodontic elastics are being increasingly used and they are primarily indicated for patients with hypersensitivity to latex. In order to evaluate and compare the behavior of latex and synthetic elastics, as the loss of strength, over time, this study was conducted both in vitro and in vivo. For the in vitro study, 15 of each elastic material was evaluated for each time: 0, 1, 3, 12 and 24 hours. For the in vivo study, patients were evaluated (N = 15) using both elastic materials (latex and synthetic) at the same times settled in vitro study. The rubber bands were transferred to the testing machine (EMIC DL-500 MF). The values of the force were recorded after stretching the elastic to a length of 25mm. Matched to the clinical and independent for laboratory sample t test was applied. Analysis of variance (ANOVA) was used to check the variation of the forces generated between those determined times and the post-hoc test to identify between which times were marked difference . As regards the initial forces (time zero), the values for synthetic elastic were quite similar between laboratory and clinical studies and slightly higher than the latex elastic. In subsequent times, the forces generated by the latex elastic showed higher values. Regarding the material degradation at the end of 24 hours, the highest percentage was observed for synthetic elastic, both in vitro and in vivo. The largest drop in the values of forces unleashed by the elastic of both materials and the clinical and laboratory studies occurred between times of 0 and 1 hour, followed by a gradual decreases until the time of 24 hours. The latex elastic had a more stable behavior during the period studied compared with synthetic, in both studies.
15

Biocompatibilidade de primers e adesivo utilizados na confecção de próteses maxilofaciais implantorretidas: análise in vitro

Bonatto, Liliane da Rocha [UNESP] 15 June 2015 (has links) (PDF)
Made available in DSpace on 2016-02-05T18:30:08Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-06-15. Added 1 bitstream(s) on 2016-02-05T18:34:15Z : No. of bitstreams: 1 000857711.pdf: 1685122 bytes, checksum: 06044cf174850099dc014984d0007cc8 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A prótese bucomaxilofacial implantorretida pode ser suportada por pele ou por mucosa. Subprodutos dos materiais utilizados na confecção destas próteses podem atuar como irritantes ou causadores de reações alérgicas a tais tecidos. A proposta do presente estudo foi avaliar a citotoxicidade de primers e adesivo utilizados na confecção de próteses maxilofaciais retidas por implantes, por meio da análise da proliferação celular e da produção de citocinas pró-inflamatórias e de proteínas de matriz extracelular por queratinócitos humanos. Foram confeccionadas 28 amostras de resina e silicone, em forma de discos (10 x 1 mm), unidas ou não pela aplicação de primer e/ou adesivo. Estas amostras foram distribuídas em 7 grupos: Resina (R), Silicone (S), Resina + Silastic Medhical Adhesive Type A + Silicone (RAS), Resina + DC 1205 primer + Silicone (RDCpS), Resina + Sofreliner primer + Silicone (RSpS), Resina + DC 1205 primer + Silastic Medhical Adhesive Type A + Silicone (RDCpAS) e Resina + Sofreliner primer + Silastic Medhical Adhesive Type A + Silicone (RSpAS). Os extratos dos materiais testados foram preparados colocando-se quatro amostras de cada grupo experimental em tubos de ensaio contendo 9 mL de meio de cultura DMEM (Dulbecco's Modified Eagle's) e incubados a 37°C por 24 horas. Após o período de incubação, a citotoxicidade dos extratos foi avaliada pelo ensaio de MTT em cultura de queratinócitos humanos (HaCaT). Foi avaliada, também, a produção das citocinas IL-1, IL-6 e TNF-α e a quimiocina MIP-1α por meio do ensaio ELISA (Ensaio Imunoabsorbente de Ligação Enzimática). Também foi avaliada a expressão de RNAm para MMP-9, TGF-β e COL-IV por meio da técnica de RT-PCR em tempo real (Reação em Cadeia da Polimerase em Tempo Real). Os dados obtidos foram submetidos à Análise de Variância (ANOVA), seguido... / The implant-retained maxillofacial prosthesis can be supported by skin and mucosa. The sub-products produced by the materials used to fabricate these prostheses may act as an irritant factor and cause allergy in these tissues. The aim of this study was to evaluate the cytotoxic effect of primers and adhesive used to bond the acrylic resin and the facial silicone during implant-retained maxillofacial prosthesis fabrication, through the analysis of the cell proliferation, and the production of proinflammatory cytokines and extracellular matrix proteins by keratinocytes. A total of 28 round shape samples (10 x 1 mm) made of resin and silicone bonded or not with primer and adhesive was fabricated. Samples were divided into 7 groups: Resin (R), Silicone (S), Resin + Silastic Medical Adhesive Type A + Silicone (RAS), Resin + DC 1205 primer + Silicone (RDCpS), Resin + Sofreliner primer + Silicone (RSpS), Resin + DC 1205 primer + Silastic Medical Adhesive Type A + Silicone (RDCpAS), and Resin + Sofreliner primer + Silastic Medical Adhesive Type A + Silicone (RSpAS). Extracts of tested materials were prepared setting four samples of each experimental group in Falcon tube with 9mL of medium (Bulbecco's Modified Eagle's) and incubated at 37°C for 24 hours. After incubation period, the extract cytotoxicity was evaluated by an assay of cell survival/proliferation (MTT test) in cultures of human keratinocytes (HaCaT). The levels of IL-1, IL-6 and TNF-α and the chemokine MIP-1α were evaluated by ELISA (Enzyme-Linked Immunoabsorbent Assay). The mRNA expression for MMP-9, TGF-β and collagen type IV were analyzed by the RT-PCR (Real time polymerase chain reaction). Data were submitted to the analysis of variance with Bonferroni post-tests (p<0.05). The results showed increased cell proliferation for the RAS group. The RDCpS group showed the highest...
16

Influência da pigmentação, técnica de união e envelhecimento acelerado sobre a resistência de união entre resina acrílica e silicone facial

Haddad, Marcela Filié [UNESP] 28 June 2013 (has links) (PDF)
Made available in DSpace on 2014-08-13T14:50:52Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-06-28Bitstream added on 2014-08-13T18:00:07Z : No. of bitstreams: 1 000764939.pdf: 4285251 bytes, checksum: 9da5ef190038848837a8d33e81f903b8 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Próteses maxilofaciais retidas por implantes necessitam de uma infraestrutura acrílica, na qual ficam contidos os sistemas de retenção; contudo, a união resina acrílica-silicone facial não é estável. Assim, este estudo teve como objetivo avaliar a influência da pigmentação com nanopartículas, técnica de união e envelhecimento acelerado sobre a resistência de união entre resina acrílica e silicone facial. Para tal, foram confeccionadas 960 amostras que consistiam em uma barra de resina acrílica de ativação química aderida ao silicone facial Silastic MDX 4-4210 incolor ou pigmentado com nanopartículas (tinta a óleo e/ou opacificador a base de sulfato de bário). A adesão entre os dois materiais foi feita pela simples deposição do silicone sobre a resina acrílica (N); por retenções mecânicas, representadas por ranhuras (R); aplicação do primer de uso médico (DC 1205 Prime - DC); primer para material reembasador (Sofreliner Primer MS- SF) ou adesivo de uso médico (Silatic Medical Adhesive Type A - A) isolados ou associados. Desta maneira, as amostras foram divididas em 4 grupos (n=240), de acordo com a nanopartícula adicionada ou não, sendo Grupo 1: Incolor; Grupo 2: Tinta a óleo; Grupo 3: Opacificador; e Grupo 4: Tinta a óleo e opacificador. Estes grupos foram divididos em 12 subgrupos (n=20), de acordo com o meio utilizado para unir a resina acrílica ao silicone, sendo: Subgrupo I: N; Subgrupo II: A; Subgrupo III: DC; Subgrupo IV: DC+A; Subgrupo V: SF; Subgrupo VI: SF+A; Subgrupo VII: R; Subgrupo VIII: R+A; Subgrupo IX: R+DC; Subgrupo X: R+DC+A; Subgrupo XI: R+SF; Subgrupo XII: R+SF+A. Metade das amostras de... / Maxillofacial prosthesis retained by implants use an acrylic framework to fit the attachment systems. However, the bond between acrylic resin and facial silicone is instable. Therefore, this study investigated the influence of nanoparticles pigments, adhesive system and accelerated aging on the bond strength between the acrylic resin and facial silicone. A total of 960 specimens made of selfpolymerized acrylic resin bar adhered to Silastic MDX 4-4210 facial silicone either colorless or pigmented with nanoparticles (oil tint and/or barium sulfate opacifier) were fabricated. The union between the two materials was performed in different ways: no treatment on the acrylic bar (N), mechanical retentions represented by scratches (R), application of prime for medical use (DC 1205 Prime - DC), primer for soft liner material (Sofreliner Primer MS - SF), and adhesive for medical use (Silastic Medical Adhesive Type A - A) alone or in combinations. The specimens were divided into 4 groups (n=240) according to the nanoparticle presence: Group 1: colorless; Group 2: oil tint; Group 3: opacifier; and Group 4: oil tint and opacifier. These groups were divided into 12 subgroups (n=20) according to the surface treatment used to bond the facial silicone to the acrylic resin: Subgroup I: N; Subgroup II: A; Subgroup III: DC; Subgroup IV: DC+A; Subgroup V: SF; Subgroup VI: SF+A; Subgroup VII: R; Subgroup VIII: R+A; Subgroup IX: R+DC; Subgroup X: R+DC+A; Subgroup XI: R+SF; Subgroup XII: R+SF+A. Half of the specimens of each subgroup (n=10) were subjected to bond strength test at the baseline period in a universal testing machine at a crosshead speed of 10 mm/min until failure. The other specimens were exposed to the accelerated... / FAPESP: 10/02937-1
17

Influência da adição de nanopartículas sobre a dureza, resistência à ruptura e deformação permanente de silicone facial submetido ao envelhecimento acelerado

Nobrega, Adhara Smith [UNESP] 20 February 2014 (has links) (PDF)
Made available in DSpace on 2015-03-03T11:52:30Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-02-20Bitstream added on 2015-03-03T12:06:36Z : No. of bitstreams: 1 000795003.pdf: 1118199 bytes, checksum: 98a54dea093e378451b9a2f7d2e032e2 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Apesar de satisfatórias, as próteses maxilofaciais apresentam limitações quanto à estética, conforto e durabilidade. Por isso estudos com o objetivo de melhorar as propriedades desses materiais são incessantes. É comprovada a eficiência da adição de nanopartículas na proteção de silicones, evitando a degradação da sua cor, no entanto a literatura é escassa quando se refere a outras alterações das propriedades físicas causadas no silicone facial. Assim, o objetivo deste estudo é avaliar a influência da adição de nanopartículas na ruptura, deformação permanente e dureza do Silicone Facial Silastic MDX4-4210. Foram confeccionadas 560 amostras em silicone facial, sendo 280 dessas amostras para o teste de ruptura, 140 para o teste de dureza e 140 para o teste de deformação permanente. As nanopartículas adicionadas na confecção das amostras de silicone foram: óxido de zinco (ZnO); sulfato de bário (BaSO4) e dióxido de titânio (TiO2). Para cada teste (exceção do teste de ruptura, no qual a quantidade de amostras será confeccionada em duplicata), 40 amostras de silicone serão confeccionadas com adição de cada um dos tipos de nanopartículas, totalizando 120 amostras; 10 amostras de silicone com tinta a óleo, sem nanopartículas, e 10 amostras somente de silicone .Para cada tipo de nanopartícula adicionada ao silicone facial, 20 amostras foram confeccionadas na concentração de 1% e 20 na concentração de 2%. Para cada concentração de nanopartículas, metade (10 amostras) foi com adição de tinta a óleo e a outra metade sem tinta a óleo. As amostras foram submetidas aos ensaios de dureza, resistência à ruptura e deformação permanente, e 1008 horas de envelhecimento acelerado. Os dados obtidos foram submetidos à análise estatística, utilizando-se os testes de nested ANOVA e teste de Tukey. Pode-se... / Although satisfactory, the maxillofacial prostheses present aesthetics, comfort and durability limitations. Therefore, studies with the purpose to obtain better properties of these materials are unceasing. The efficiency of adding nanoparticles to silicon protection is well proven in preventing its color degradation, however the literature is scarce when it comes to other physical property changes with infacial silicon.The aim of this study is to evaluate the influence of nanoparticles addition to hardness, rupture resistance and permanent deformation of Facial Silicone Silastic MDX4-4210. 560 samples of facial silicone were made, 280 for rupture resistance test, 140 for hardness test and 140 for permanent deformation test. Nanoparticles added in the preparation of silicone samples were zinc oxide (ZnO), barium sulfate (BaSO4) and titanium dioxide (TiO2). For each test (except the rupture test, in which the samples are duplicated), 40 samples will be made of silicon added to each type of nanoparticles, totaling 120 samples, 10 samples of silicone with oil paint without nanoparticles, and 10 samples only of silicone (control group). For each type of nanoparticle added to the facial silicone, 20 samples were prepared at a concentration of 1% and 20 at a concentration of 2%. For every concentration of nanoparticles, half (10 samples) were added oil paint and the other half without oil paint. Samples were submitted to testing hardness, rupture resistance and permanent deformation, and 1008 hours of accelerated aging. The data were subjected to statistical analysis using nested ANOVA and Tukey tests. It can be verified through the results that the presence of nanoparticles influenced the hardness, tear strength and permanent deformation of the assessed groups. We conclude that all evaluated nanoparticles influenced the hardness, tear strength and permanent... / FAPESP: 12/05270-3
18

Avaliação da biocompatibilidade de vários elastômeros de silicone implantados no tecido subcutâneo de ratos : estudo histológico e histomorfométrico /

França, Diurianne Caroline Campos. January 2005 (has links)
Orientador: Alvimar Lima de Castro / Banca: Hélio Massaiochi Tanimoto / Banca: Ana Maria Pires Soubhia / Resumo: No presente estudo foram utilizados 60 ratos submetidos a implantes subcutâneos de quatro elastômeros de silicone, sendo três usados em prótese bucomaxilofacial, LIM 6050, MDX 4-4210 e Silastic 732 RTV industrial e um indicado para cirurgia plástica, o Silimed. O objetivo do estudo foi avaliar os materiais em relação à compatibilidade biológica tecidual, nos tempos pós-operatórios de sete, quinze e trinta dias, quando os animais foram sacrificados e as peças processadas e coradas pela hematoxilina e eosina para análise qualitativa e quantitativa dos espécimes. Pelo estudo histomorfométrico, oito áreas de 60,11 mm2 foram analisadas, contando-se as células mesenquimais, inflamatórias mononucleares, eosinófilos e as células gigantes do tipo corpo estranho. O experimento foi desenvolvido em dois capítulos, estudando-se separadamente os silicones de uso em prótese e o Silimed. No primeiro capítulo, a análise da biocompatibilidade dos implantes subcutâneos dos elastômeros de silicone LIM 6050, MDX 4-4210 e Silastic 732 RTV industrial, observou-se biocompatibilidade aceitável em todos eles, considerando-se o fato de que sua indicação protética dependeria em especial das características físicas próprias de cada material, pela mínima reação tecidual observada, além de que em sua forma sólida é fácil a adaptação aos tecidos. No segundo capítulo, o estudo se baseou na análise das reações referentes ao implante de silicone utilizado em cirurgia plástica (Silimed), constatando-se a presença de processo inflamatório ligeiramente maior no silicone gel em relação aos outros grupos, porém com níveis aceitáveis de biocompatibilidade, confirmada pela rara presença de células gigantes do tipo corpo estranho. Todos os dados foram submetidos à análise de variância e teste de Tukey, demonstrando que todos os materiais implantados iniciaram uma resposta... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: In the present study 60 rats were submitted to subcutaneous implant of four elastomers of silicon, being three of use in bucomaxillofacial prosthesis, LIM 6050, MDX 4-4210 and Silastic 732 RTV industrial and a suitable one for plastic surgery, Silimed. The objective of the study was to evaluate the materials in relation to the tissue biological compatibility, in the postoperative times of seven, fifteen and thirty days, when the animals were sacrificed and the processed pieces and stained for the hematoxilin and eosin for qualitative and quantitative analysis of the specimens. For the histomorphometric study, eight areas of 60,11 mm2 were analyzed, being counted the mesenchimal cells, inflammatory cells, eosinophile and giant cells. The experiment was developed in two chapters, being studied the use silicons separately in prosthesis and Silimed. In the first chapter, the analysis of the biocompatibility of the subcutaneous implant of the elastomers of silicon LIM 6050, MDX 4-4210 and Silastic 732 RTV industrial, acceptable biocompatibility was observed in all of them, being considered the fact that your prosthetic indication would especially depend on the own physical characteristics of each material, for the low tissue reaction observed, in addition in your solid form it is easy the adaptation to the tissues. In the second chapter, the study based on the analysis of the referring reactions to the it implants of silicon used in plastic surgery (silimed), being verified the presence of inflammatory process lightly larger in relation to the other groups, however with acceptable levels of biocompatibility confirmed by the rare presence of giant cells of the type strange body. All the data were submitted to the variance analysis and test of Tukey, demonstrating that all the implanted materials began an acceptable tissue inflammatory reaction, with tissue reactions of light intensity the moderate... (Complete abstract, click electronic address below) / Mestre
19

Biocompatibilidade de primers e adesivo utilizados na confecção de próteses maxilofaciais implantorretidas : análise in vitro /

Bonatto, Liliane da Rocha. January 2015 (has links)
Orientadora: Daniela Micheline dos Santos / Coorientador: Marcelo Coelho Goiato / Banca: Marcela Fillié Haddad / Banca: Sandra Helena Penha de Oliveira / Resumo: A prótese bucomaxilofacial implantorretida pode ser suportada por pele ou por mucosa. Subprodutos dos materiais utilizados na confecção destas próteses podem atuar como irritantes ou causadores de reações alérgicas a tais tecidos. A proposta do presente estudo foi avaliar a citotoxicidade de primers e adesivo utilizados na confecção de próteses maxilofaciais retidas por implantes, por meio da análise da proliferação celular e da produção de citocinas pró-inflamatórias e de proteínas de matriz extracelular por queratinócitos humanos. Foram confeccionadas 28 amostras de resina e silicone, em forma de discos (10 x 1 mm), unidas ou não pela aplicação de primer e/ou adesivo. Estas amostras foram distribuídas em 7 grupos: Resina (R), Silicone (S), Resina + Silastic Medhical Adhesive Type A + Silicone (RAS), Resina + DC 1205 primer + Silicone (RDCpS), Resina + Sofreliner primer + Silicone (RSpS), Resina + DC 1205 primer + Silastic Medhical Adhesive Type A + Silicone (RDCpAS) e Resina + Sofreliner primer + Silastic Medhical Adhesive Type A + Silicone (RSpAS). Os extratos dos materiais testados foram preparados colocando-se quatro amostras de cada grupo experimental em tubos de ensaio contendo 9 mL de meio de cultura DMEM (Dulbecco's Modified Eagle's) e incubados a 37°C por 24 horas. Após o período de incubação, a citotoxicidade dos extratos foi avaliada pelo ensaio de MTT em cultura de queratinócitos humanos (HaCaT). Foi avaliada, também, a produção das citocinas IL-1, IL-6 e TNF-α e a quimiocina MIP-1α por meio do ensaio ELISA (Ensaio Imunoabsorbente de Ligação Enzimática). Também foi avaliada a expressão de RNAm para MMP-9, TGF-β e COL-IV por meio da técnica de RT-PCR em tempo real (Reação em Cadeia da Polimerase em Tempo Real). Os dados obtidos foram submetidos à Análise de Variância (ANOVA), seguido... / Abstract: The implant-retained maxillofacial prosthesis can be supported by skin and mucosa. The sub-products produced by the materials used to fabricate these prostheses may act as an irritant factor and cause allergy in these tissues. The aim of this study was to evaluate the cytotoxic effect of primers and adhesive used to bond the acrylic resin and the facial silicone during implant-retained maxillofacial prosthesis fabrication, through the analysis of the cell proliferation, and the production of proinflammatory cytokines and extracellular matrix proteins by keratinocytes. A total of 28 round shape samples (10 x 1 mm) made of resin and silicone bonded or not with primer and adhesive was fabricated. Samples were divided into 7 groups: Resin (R), Silicone (S), Resin + Silastic Medical Adhesive Type A + Silicone (RAS), Resin + DC 1205 primer + Silicone (RDCpS), Resin + Sofreliner primer + Silicone (RSpS), Resin + DC 1205 primer + Silastic Medical Adhesive Type A + Silicone (RDCpAS), and Resin + Sofreliner primer + Silastic Medical Adhesive Type A + Silicone (RSpAS). Extracts of tested materials were prepared setting four samples of each experimental group in Falcon tube with 9mL of medium (Bulbecco's Modified Eagle's) and incubated at 37°C for 24 hours. After incubation period, the extract cytotoxicity was evaluated by an assay of cell survival/proliferation (MTT test) in cultures of human keratinocytes (HaCaT). The levels of IL-1, IL-6 and TNF-α and the chemokine MIP-1α were evaluated by ELISA (Enzyme-Linked Immunoabsorbent Assay). The mRNA expression for MMP-9, TGF-β and collagen type IV were analyzed by the RT-PCR (Real time polymerase chain reaction). Data were submitted to the analysis of variance with Bonferroni post-tests (p<0.05). The results showed increased cell proliferation for the RAS group. The RDCpS group showed the highest... / Mestre
20

Influência da adição de nanopartículas sobre a dureza, resistência à ruptura e deformação permanente de silicone facial submetido ao envelhecimento acelerado /

Nobrega, Adhara Smith. January 2014 (has links)
Orientador: Marcelo Coelho Goiato / Banca: Daniela Micheline dos Santos / Banca: Mário Alexandre Coelho Sinhoreti / Resumo: Apesar de satisfatórias, as próteses maxilofaciais apresentam limitações quanto à estética, conforto e durabilidade. Por isso estudos com o objetivo de melhorar as propriedades desses materiais são incessantes. É comprovada a eficiência da adição de nanopartículas na proteção de silicones, evitando a degradação da sua cor, no entanto a literatura é escassa quando se refere a outras alterações das propriedades físicas causadas no silicone facial. Assim, o objetivo deste estudo é avaliar a influência da adição de nanopartículas na ruptura, deformação permanente e dureza do Silicone Facial Silastic MDX4-4210. Foram confeccionadas 560 amostras em silicone facial, sendo 280 dessas amostras para o teste de ruptura, 140 para o teste de dureza e 140 para o teste de deformação permanente. As nanopartículas adicionadas na confecção das amostras de silicone foram: óxido de zinco (ZnO); sulfato de bário (BaSO4) e dióxido de titânio (TiO2). Para cada teste (exceção do teste de ruptura, no qual a quantidade de amostras será confeccionada em duplicata), 40 amostras de silicone serão confeccionadas com adição de cada um dos tipos de nanopartículas, totalizando 120 amostras; 10 amostras de silicone com tinta a óleo, sem nanopartículas, e 10 amostras somente de silicone .Para cada tipo de nanopartícula adicionada ao silicone facial, 20 amostras foram confeccionadas na concentração de 1% e 20 na concentração de 2%. Para cada concentração de nanopartículas, metade (10 amostras) foi com adição de tinta a óleo e a outra metade sem tinta a óleo. As amostras foram submetidas aos ensaios de dureza, resistência à ruptura e deformação permanente, e 1008 horas de envelhecimento acelerado. Os dados obtidos foram submetidos à análise estatística, utilizando-se os testes de nested ANOVA e teste de Tukey. Pode-se... / Abstract: Although satisfactory, the maxillofacial prostheses present aesthetics, comfort and durability limitations. Therefore, studies with the purpose to obtain better properties of these materials are unceasing. The efficiency of adding nanoparticles to silicon protection is well proven in preventing its color degradation, however the literature is scarce when it comes to other physical property changes with infacial silicon.The aim of this study is to evaluate the influence of nanoparticles addition to hardness, rupture resistance and permanent deformation of Facial Silicone Silastic MDX4-4210. 560 samples of facial silicone were made, 280 for rupture resistance test, 140 for hardness test and 140 for permanent deformation test. Nanoparticles added in the preparation of silicone samples were zinc oxide (ZnO), barium sulfate (BaSO4) and titanium dioxide (TiO2). For each test (except the rupture test, in which the samples are duplicated), 40 samples will be made of silicon added to each type of nanoparticles, totaling 120 samples, 10 samples of silicone with oil paint without nanoparticles, and 10 samples only of silicone (control group). For each type of nanoparticle added to the facial silicone, 20 samples were prepared at a concentration of 1% and 20 at a concentration of 2%. For every concentration of nanoparticles, half (10 samples) were added oil paint and the other half without oil paint. Samples were submitted to testing hardness, rupture resistance and permanent deformation, and 1008 hours of accelerated aging. The data were subjected to statistical analysis using nested ANOVA and Tukey tests. It can be verified through the results that the presence of nanoparticles influenced the hardness, tear strength and permanent deformation of the assessed groups. We conclude that all evaluated nanoparticles influenced the hardness, tear strength and permanent... / Mestre

Page generated in 0.0894 seconds