• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 66
  • 4
  • Tagged with
  • 70
  • 70
  • 70
  • 20
  • 16
  • 12
  • 8
  • 8
  • 7
  • 7
  • 6
  • 6
  • 6
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

PMU based PSS and SVC fuzzy controller design for angular stability analysis

Ahmed, Sheikh January 1900 (has links)
Master of Science / Department of Electrical and Computer Engineering / Shelli Starrett / Variability in power systems is increasing due to pushing the system to limits for economic purposes, the inclusion of new energy sources like wind turbines and photovoltaic, and the introduction of new types of loads such as electric vehicle chargers. In this new environment, system monitoring and control must keep pace to insure system stability and reliability on a wide area scale. Phasor measurement unit technology implementation is growing and can be used to provide input signals to new types of control. Fuzzy logic based power system stabilizer (PSS) controllers have also been shown effective in various studies. This thesis considers several choices of input signals, composed assuming phasor measurement availability, for fuzzy logic-based controllers. The purpose of the controller is to damp power systems’ low frequency oscillations. Nonlinear transient simulation results for a 4-machine two-area system and 50 machine system are used to compare the effects of input choice and controller type on damping of system oscillations. Reactive power in the system affects voltage, which in turn affects system damping and dynamic stability. System stability and damping can be enhanced by deploying SVC controllers properly. Different types of power system variables play critical role to damp power swings using SVC controller. A fuzzy logic based static var compensator (SVC) was used near a generator to damp these electromechanical oscillations using different PMU-acquired inputs. The goal was again improve dynamic stability and damping performance of the system at local and global level. Nonlinear simulations were run to compare the damping performance of different inputs on the 50 machine system.
62

Flux growth and characteristics of cubic boron phosphide

Nwagwu, Ugochukwu January 1900 (has links)
Master of Science / Department of Chemical Engineering / J. H. Edgar / Boron phosphide, BP, is a III-V compound semiconductor with a wide band gap of 2.0 eV that is potentially useful in solid state neutron detectors because of the large thermal neutron capture cross-section of the boron-10 isotope (3840 barns). In this study, cubic BP crystals were grown by crystallizing dissolved boron and phosphorus from a nickel solvent in a sealed (previously evacuated) quartz tube. The boron - nickel solution was located at one end of the tube and held at 1150°C. Phosphorus, initially at the opposite end of the tube at a temperature of 430°C, vaporized, filling the tube to a pressure of 1–5 atmospheres. The phosphorus then dissolved into solution, producing BP. Transparent red crystals up to 4 mm in the largest dimension with mostly hexagonal shape were obtained with a cooling rate of 3°C per hour. The crystal size decreased as the cooling rate increased, and also as growth time decreased. The characterization with x-ray diffraction (XRD) and Raman spectroscopy established that the BP produced through this method were highly crystalline. The lattice constant of the crystals was 4.534 Ǻ, as measured by x-ray diffraction. Intense, sharp Raman phonon peaks were located at 800 cm[superscript]-1 and 830 cm[superscript]-1, in agreement with the values reported in the literature. The FWHM for XRD and Raman spectra were 0.275° and 4 cm[superscript]-1 which are the narrowest ever reported and demonstrates the high quality of the produced crystals. Energy dispersive x-ray spectroscopy (EDS) and scanning electron microscope (SEM) also confirmed the synthesized crystals were cubic BP crystals, with a boron to phosphorus atomic ratio of 1:1. Defect selective etching of BP at 300ºC for two minutes with molten KOH/NaOH revealed triangular and striated etch pits with low densities of defects of ~4 x 10[superscript]7 cm[superscript]-2 and 9.2 x 10[superscript]7 cm[superscript]-2 respectively. The BP crystals were n-type, and an electron mobility of ~39.8 cm[superscript]2/V*s was measured. This is favorable for application in neutron detection. Scaling to larger sizes is the next step through gradient freezing and employing a larger crucible.
63

Real-time simulation of shipboard power system and energy storage device management

Li, Dingyi January 1900 (has links)
Master of Science / Department of Electrical and Computer Engineering / Noel Schulz / Many situations can cause a fault on a shipboard power system, especially in naval battleships. Batteries and ultra-capacitors are simulated to be backup energy storage devices (ESDs) to power the shipboard power system when an outage or damage occurs. Because ESDs have advantages such as guaranteed load leveling, good transient operation, and energy recovery during braking operation, they are commonly used for electrical ship applications. To fulfill these requirements, an energy management subsystem (EMS) with a specific control algorithm must connect ESDs to the dc link of the motor drive system. In this research, the real-time simulation of shipboard power system (SPS), bidirectional DC-DC converter, EMS, and ESDs are designed, implemented, and controlled on OPAL-RT system to test SPS survivability and ESD performance in various speed operations.
64

Wireless body area networks for intra-spacesuit communications: modeling, measurements and wearable antennas

Taj-Eldin, Mohammed January 1900 (has links)
Doctor of Philosophy / Department of Electrical and Computer Engineering / William B. Kuhn / Balasubramaniam Natarajan / Wireless body area networks (WBANs) are an important part of the developing internet of things (IOT). NASA currently uses space suits with wired sensors to collect limited biomedical data. Continuous monitoring and collecting more extensive body vital signs is important to assess astronaut health. This dissertation investigates wireless biomedical sensor systems that can be easily incorporated into future space suits to enable real time astronaut health monitoring. The focus of the work is on the radio-wave channel and associated antennas. We show that the space suit forms a unique propagation environment where the outer layers of the suit’s thermal micrometeoroid garment are largely radio opaque. This environment can be modeled as a coaxial one in which the body itself plays the role of the coax center conductor while the space suit shielding materials play the role of the outer shield. This model is then validated through simulations and experiments. Selecting the best frequency of operation is a complex mixture of requirements, including frequency allocations, attenuation in propagation, and antenna size. We investigate the propagation characteristics for various frequency bands from 315 MHz to 5.2 GHz. Signal attenuation is analyzed as a function of frequency for various communication pathways through 3D simulations and laboratory experiments. Small-scale radio channel results indicate that using lower frequency results in minimal path loss. On the other hand, measurements conducted on a full-scale model suggest that 433 MHz and 2400 MHz yield acceptable path loss values. Propagation between the left wrist and left ankle yielded the worst overall path loss, but signals were still above –100 dBm in raw measurements for a 0dBm transmission indicating that the intra-suit environment is conducive to wireless propagation. Our findings suggest that the UHF bands are best candidate bands since there is interplay between the body conductivity favoring lower frequencies, and the difficulty of coupling RF energy into and out of the channel using suitably sized antennas favoring higher frequencies. Finally, a new self-shielded folded bow-tie antenna is proposed that can be a promising choice for the general area of WBAN technologies as well as potential new space suit environments.
65

Advanced microstructured semiconductor neutron detectors: design, fabrication, and performance

Bellinger, Steven Lawrence January 1900 (has links)
Doctor of Philosophy / Department of Mechanical and Nuclear Engineering / Douglas S. McGregor / The microstructured semiconductor neutron detector (MSND) was investigated and previous designs were improved and optimized. In the present work, fabrication techniques have been refined and improved to produce three-dimensional microstructured semiconductor neutron detectors with reduced leakage current, reduced capacitance, highly anisotropic deep etched trenches, and increased signal-to-noise ratios. As a result of these improvements, new MSND detection systems function with better gamma-ray discrimination and are easier to fabricate than previous designs. In addition to the microstructured diode fabrication improvement, a superior batch processing backfill-method for 6LiF neutron reactive material, resulting in a nearly-solid backfill, was developed. This method incorporates a LiF nano-sizing process and a centrifugal batch process for backfilling the nanoparticle LiF material. To better transition the MSND detector to commercialization, the fabrication process was studied and enhanced to better facilitate low cost and batch process MSND production. The research and development of the MSND technology described in this work includes fabrication of variant microstructured diode designs, which have been simulated through MSND physics models to predict performance and neutron detection efficiency, and testing the operational performance of these designs in regards to neutron detection efficiency, gamma-ray rejection, and silicon fabrication methodology. The highest thermal-neutron detection efficiency reported to date for a solid-state semiconductor detector is presented in this work. MSNDs show excellent neutron to gamma-ray (n/γ) rejection ratios, which are on the order of 106, without significant loss in thermal-neutron detection efficiency. Individually, the MSND is intrinsically highly sensitive to thermal neutrons, but not extrinsically sensitive because of their small size. To improve upon this, individual MSNDs were tiled together into a 6x6-element array on a single silicon chip. Individual elements of the array were tested for thermal-neutron detection efficiency and for the n/γ reject ratio. Overall, because of the inadequacies and costs of other neutron detection systems, the MSND is the premier technology for many neutron detection applications.
66

The evaluation of software defined networking for communication and control of cyber physical systems

Sydney, Ali January 1900 (has links)
Doctor of Philosophy / Department of Electrical and Computer Engineering / Don Gruenbacher / Caterina Scoglio / Cyber physical systems emerge when physical systems are integrated with communication networks. In particular, communication networks facilitate dissemination of data among components of physical systems to meet key requirements, such as efficiency and reliability, in achieving an objective. In this dissertation, we consider one of the most important cyber physical systems: the smart grid. The North American Electric Reliability Corporation (NERC) envisions a smart grid that aggressively explores advance communication network solutions to facilitate real-time monitoring and dynamic control of the bulk electric power system. At the distribution level, the smart grid integrates renewable generation and energy storage mechanisms to improve reliability of the grid. Furthermore, dynamic pricing and demand management provide customers an avenue to interact with the power system to determine electricity usage that satisfies their lifestyle. At the transmission level, efficient communication and a highly automated architecture provide visibility in the power system; hence, faults are mitigated faster than they can propagate. However, higher levels of reliability and efficiency rely on the supporting physical communication infrastructure and the network technologies employed. Conventionally, the topology of the communication network tends to be identical to that of the power network. In this dissertation, however, we employ a Demand Response (DR) application to illustrate that a topology that may be ideal for the power network may not necessarily be ideal for the communication network. To develop this illustration, we realize that communication network issues, such as congestion, are addressed by protocols, middle-ware, and software mechanisms. Additionally, a network whose physical topology is designed to avoid congestion realizes an even higher level of performance. For this reason, characterizing the communication infrastructure of smart grids provides mechanisms to improve performance while minimizing cost. Most recently, algebraic connectivity has been used in the ongoing research effort characterizing the robustness of networks to failures and attacks. Therefore, we first derive analytical methods for increasing algebraic connectivity and validate these methods numerically. Secondly, we investigate impact on the topology and traffic characteristics as algebraic connectivity is increased. Finally, we construct a DR application to demonstrate how concepts from graph theory can dramatically improve the performance of a communication network. With a hybrid simulation of both power and communication network, we illustrate that a topology which may be ideal for the power network may not necessarily be ideal for the communication network. To date, utility companies are embracing network technologies such as Multiprotocol Label Switching (MPLS) because of the available support for legacy devices, traffic engineering, and virtual private networks (VPNs) which are essential to the functioning of the smart grid. Furthermore, this particular network technology meets the requirement of non-routability as stipulated by NERC, but these benefits are costly for the infrastructure that supports the full MPLS specification. More importantly, with MPLS routing and other switching technologies, innovation is restricted to the features provided by the equipment. In particular, no practical method exists for utility consultants or researchers to test new ideas, such as alternatives to IP or MPLS, on a realistic scale in order to obtain the experience and confidence necessary for real-world deployments. As a result, novel ideas remain untested. On the contrary, OpenFlow, which has gained support from network providers such as Microsoft and Google and equipment vendors such as NEC and Cisco, provides the programmability and flexibility necessary to enable innovation in next-generation communication architectures for the smart grid. This level of flexibility allows OpenFlow to provide all features of MPLS and allows OpenFlow devices to co-exist with existing MPLS devices. Therefore, in this dissertation we explore a low-cost OpenFlow Software Defined Networking solution and compare its performance to that of MPLS. In summary, we develop methods for designing robust networks and evaluate software defined networking for communication and control in cyber physical systems where the smart grid is the system under consideration.
67

Automated hand-forearm ergometer data acquisition and analysis system

Gude, Dana Maxine January 1900 (has links)
Master of Science / Department of Electrical & Computer Engineering / Steve Warren / Handgrip contractions are a standard exercise modality to evaluate muscular system performance. Most conventional ergometer systems that collect handgrip contraction data are manually controlled, placing a burden on the researcher to guide subject activity while recording the resultant data. Further, post-processing tools for this type of experiment are not standardized within the domain, which requires investigators to process their data with multiple tool sets and often create custom tool sets for that purpose. This can make experimental data difficult to compare and correlate, even within the same research group. This thesis presents updates to a hand-forearm ergometer system that automate the control and data-acquisition processes as well as provide a tool set to post process hand contraction data. The automated system utilizes a LabVIEW virtual instrument as the system centerpiece; it provides the subject/researcher interfaces and coordinates data acquisition from both traditional and new sensors. The tool set also incorporates a collection of MATLAB scripts that allow the investigator to post process these data in a standard way, such as automating the processes of noise floor removal, burst start/stop time identification, and mean/median frequency calculation in electromyograms (EMGs). The tool set has proven to be a viable support resource for experimental studies performed by the Kansas State University Human Exercise Physiology lab that target muscle fatigue in human forearms. Initial data acquired during these tests indicate the viability of the system to acquire consistent and physiologically meaningful data while providing a usable tool set for follow-on data analyses.
68

DC microgrids: review and applications

Blasi, Bronson Richard January 1900 (has links)
Master of Science / Department of Architectural Engineering and Construction Science / Fred Hasler / This paper discusses a brief history of electricity, specifically alternating current (AC) and direct current (DC), and how the current standard of AC distribution has been reached. DC power was first produced in 1800, but the shift to AC occurred in the 1880’s with the advent of the transformer. Because the decisions for distribution were made over 100 years ago, it could be time to rethink the standards of power distribution. Compared to traditional AC distribution, DC microgrids are significantly more energy efficient when implemented with distributed generation. Distributed generation, or on-site generation from photovoltaic panels, wind turbines, fuel cells, or microturbines, is more efficient when the power is transmitted by DC. DC generation, paired with the growing DC load profile, increases energy savings by utilizing DC architecture and eliminating wasteful conversions. Energy savings would result from a lower grid strain and more efficient utilization of the utility grid. DC distribution results in a more reliable electrical service due to short transmission distances, high service reliability when paired with on-site generation, and efficient storage. Occupant safety is a perceived concern with DC microgrids due to the lack of knowledge and familiarity in regards to these systems. However, with proper regulation and design standards, building occupants never encounter voltage higher than 24VDC, which is significantly safer than existing 120VAC in the United States. DC Microgrids have several disadvantages such as higher initial cost due, in part, to unfamiliarity of the system as well as a general lack of code recognition and efficiency metric recognition leading to difficult certification and code compliance. Case studies are cited in this paper to demonstrate energy reduction possibilities due to the lack of modeling ability in current energy analysis programs and demonstrated energy savings of approximately 20%. It was concluded that continued advancement in code development will come from pressure to increase energy efficiency. This pressure, paired with the standardization of a 24VDC plug and socket, will cause substantial increases in DC microgrid usage in the next 10 years.
69

Cost-benefit analysis of mitigation of outages caused by squirrels on the overhead electricity distribution systems

Malve, Priyanka January 1900 (has links)
Master of Science / Department of Electrical and Computer Engineering / Anil Pahwa / Unpredictable power outages due to environmental factors such as lighting, wind, trees, and animals, have always been a concern for utilities because they are often unavoidable. This research aims to study squirrel-related outages by modeling past real-life outage data and provide the optimal result which would assist utilities in increasing electric system reliability. This research is a novel approach to benchmark system performance in order to identify areas and durations with higher than expected outages. The model is illustrated with seven years (2005-2011) of animal-related outage data and 14 years of weather data (1998-2011) for four cities in Kansas, used as training data to predict future outages. The past data indicates that the number of outages on any day varies with the seasons and weather conditions on that day. The prediction is based on a Bayesian Model using conditional probability table, which is calculated based on training data. Since future weather conditions are unknown and random, Monte Carlo Simulation is used with the past 14 years of weather data to create different yearly scenarios. These scenarios are then used with the models to predict expected outages. Multiple runs of Monte Carlo analysis provide a probability distribution of expected outages. Further work discusses about cost-to-benefit analysis of implementation of outage mitigation methods. The analysis is performed by considering different combinations of outage reduction and mitigation levels. In this research, eight cases of outage reduction and nine cases of mitigation levels are defined. The probability of benefit is calculated by a statistical approach for every combination. Several optimal strategies are constructed using the probability values and outage history. The outcomes are compared with each other to propose the most beneficial outage mitigation strategy. This research will immensely assist utilities in reducing the outages due to squirrels more effectively with higher benefits and therefore improve reliability of the electricity supply to consumers.
70

Relay in the loop test procedures for adaptive overcurrent protection

Piesciorovsky, Emilio C. January 1900 (has links)
Doctor of Philosophy / Electrical and Computer Engineering / Anil Pahwa / Noel N. Schulz / Microgrids with distributed generators have changed how protection and control systems are designed. Protection systems in conventional U.S. distribution systems are radial with the assumption that current flows always from the utility source to the end user. However, in a microgrid with distributed generators, currents along power lines do not always flow in one direction. Therefore, protection systems must be adapted to different circuit paths depending on distributed generator sites in the microgrid and maximum fuse ampere ratings on busses. Adaptive overcurrent protection focuses on objectives and constraints based on operation, maximum load demand, equipment, and utility service limitations. Adaptive overcurrent protection was designed to protect the power lines and bus feeders of the microgrid with distributed generators by coordinating fuses and relays in the microgrid. Adaptive overcurrent protection was based on the relay setting group and protection logic methods. Non-real-time simulator (NRTS) and real-time simulator (RTS) experiments were performed with computer-based simulators. Tests with two relays in the loop proved that primary relays tripped faster than backup relays for selectivity coordination in the adaptive overcurrent protection system. Relay test results from tripping and non-tripping tests showed that adaptive inverse time overcurrent protection achieved selectivity, speed, and reliability. The RTS and NRTS with two relays in the loop techniques were described and compared in this work. The author was the first graduate student to implement real-time simulation with two relays in the loop at the Burns & McDonnell - K-State Smart Grid Laboratory. The RTS experimental circuit and project are detailed in this work so other graduate students can apply this technique with relays in the loop in smart grid research areas such as phasor measurement units, adaptive protection, communication, and cyber security applications.

Page generated in 0.0878 seconds