• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • 1
  • Tagged with
  • 5
  • 5
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Gastric electrical stimulation studies in patients with intractable nausea and comiting /

Andersson, Stina, January 2010 (has links)
Diss. (sammanfattning) Göteborg : Univ. , 2010.
2

Estudo da segurança e da estabilidade do implante de cabo-eletrodo atrial direito pela via epidemiocárdiaca através do seio transverso em modelo animal suíno / Evaluation of safety and stability of right atrial lead implantation by epimyocardial access through the transverse sinus in a swine model

Bueno, Sávia Christina Pereira 13 June 2013 (has links)
Introdução: Embora o implante de marcapasso atrioventricular pela via endovenosa seja considerado o estado da arte, situações clínicas e técnicas que podem impossibilitar o implante transvenoso de cabos-eletrodos têm sido cada vez mais frequentes, tornando-se necessária a proposição de abordagens cirúrgicas alternativas. Objetivos: O presente estudo visou o implante de marcapasso atrioventricular utilizando nova técnica para implante de cabo-eletrodo atrial no átrio direito, com o objetivo de avaliar no período intra-operatório e nos 30 primeiros dias de seguimento: a segurança e a reprodutibilidade do procedimento cirúrgico; a taxa de deslocamento dos cabos-eletrodos; as condições de estimulação e sensibilidade; as alterações morfológicas na cavidade pericárdica e as alterações histopatológicas epimiocárdicas. Métodos: Sob anestesia geral, foram operados 10 porcos adultos da raça Large White. Os cabos-eletrodos foram implantados, sob visão direta, no ventrículo esquerdo e no átrio direito, pelo seio transverso, através de toracotomia anterolateral esquerda. As condições de estimulação e de sensibilidade para os cabos-eletrodos atrial e ventricular, nas configurações unipolar e bipolar, foram avaliadas no intra-operatório, pós-operatório imediato, no 7º e 30º dias de pós-operatório. Ao final do estudo, os animais foram reoperados por toracotomia longitudinal mediana para observação das aderências pericárdicas e análise das condições histopatológicas da junção entre o cabo-eletrodo e o epimiocárdico. Resultados: Todos os animais permaneceram vivos até o último dia do estudo, não tendo ocorrido complicações intra-operatórias graves. As condições de estimulação e sensibilidade para os cabos-eletrodos atriais e ventriculares, nas configurações unipolar e bipolar, mantiveram-se estáveis ao longo do estudo e apresentaram comportamento semelhante. Notou-se aumento progressivo dos limiares atriais, variando de 0,50 ± 0,38 a 1,86 ± 1,31 volts nos períodos intra-operatório e 30o pós-operatório, respectivamente. Comportamento semelhante foi observado para os limiares ventriculares, que variaram de 0,43 ± 0,23 volts, no intra-operatório, a 1,22 ± 0,49 volts, no 30o pós-operatório. As medidas de impedância atrial e ventricular apresentaram uma discreta queda ao longo do tempo, sendo que a impedância atrial variou de 486,80 ± 126,35 a 385,0 ± 80,52 Ohms no período intra-operatório e 30o pós-operatório, respectivamente. A impedância ventricular variou de 700,40 ± 203,67 Ohms, no intra-operatório, a 409,30 ± 58,96 Ohms, no 30o pós-operatório. A sensibilidade, tanto em átrio quanto em ventrículo, mostrou-se estável a partir do pós-operatório imediato. A inspeção da cavidade pericárdica mostrou aderências em todos os animais e em todas as regiões avaliadas, não sendo observados derrame ou constrição pericárdica. A análise microscópica mostrou que o contato com os cabos-eletrodos provocou espessamento do epimiocárdio no átrio direito, ventrículo esquerdo e na artéria pulmonar. A cicatriz formada na junção entre o cabo-eletrodo e o epimiocárdio atrial foi semelhante à formada na região do implante dos cabos-eletrodos ventriculares. Conclusões: O implante do cabo-eletrodo atrial direito pelo seio transverso foi seguro e reprodutível. A efetividade do procedimento foi confirmada pelas condições estáveis de estimulação e de sensibilidade durante o período de seguimento pós-operatório. A única alteração morfológica encontrada na cavidade pericárdica foi a formação de aderências. Ocorreu adequada cicatrização na junção entre o cabo eletrodo e o epimiocárdio atrial / Introduction: Although transvenous access for atrioventricular pacemaker implantation is considered the state of the art, clinical and technical situations that may impede transvenous leads implantation have become increasingly common, making it necessary the proposal of new surgical approaches. Objectives: The present study was design to perform the implant of atrioventricular pacemaker using a new technique for placement of the atrial lead in the right atrium, aiming to evaluate in the intraoperative period and during the first 30 days of follow-up: the safety and reproducibility of the surgical procedure; lead dislodgment rate; conditions of pacing and sensing; morphological changes in the pericardium, as well as, histopathological changes in the epimyocardium. Methods: A total of 10 Large White adult pigs underwent pacemaker implantation under general anesthesia. By using an anterolateral thoracotomy, leads were implanted under visual guidance in the left ventricle and in the right atrium through the transverse sinus. Pacing and sensing parameters, in unipolar and bipolar modes, were obtained during the intraoperative and immediate postoperative period and on the 7th and the 30th postoperative day. At the end of the study, all animals underwent reoperation by thoracotomy through a median longitudinal sternotomy for evaluation of pericardial adhesions and histopathological analysis of the junction between the lead and epimyocardial wall. Results: All animals were alive until the end of the study and there were no serious intraoperative complications. Pacing and sensing parameters for atrial and ventricular leads in both unipolar and bipolar modes remain stable throughout the study and showed similar performance. We observed a progressive increase in atrial thresholds, ranging from 0.50 ± 0.38 to 1.86 ± 1.31 volts, during the intraoperative and on the 30-day postoperative, respectively. Similar result was observed for ventricular thresholds, which ranged from 0.43 ± 0.23 volts, intraoperatively, to 1.22 ± 0.49 volts on the 30-day postoperative. Atrial and ventricular impedance measurements decreased slightly over time, and the atrial impedance ranged from 486.80 ± 126.35 to 385.0 ± 80.52 Ohms during the intraoperative and on the 30-day postoperative, respectively. Ventricular impedance ranged from 700.40 ± 203.67 Ohms, intraoperatively, to 409.30 ± 58.96 Ohms, on the 30-day postoperative. Both atrial and ventricular sensing measurements remain stable since the immediate postoperative period. Pericardial adhesions were found in all animals and in all studied regions. There was no noticeable pericardial effusion or myocardial constriction. Microscopic analysis showed that contact with the electrode had caused thickening of the right atrium, left ventricle and pulmonary artery. Similar scar formation was found at the interface between atrial lead and epimyocardial, such as ventricular lead and epimyocardial. Conclusion: Implantation of the right atrial lead through the transverse sinus was safe and reproducible. The effectiveness of the procedure was confirmed by stable conditions of pacing and sensing parameters throughout the postoperative follow-up. Pericardial adhesion was the only change found in the pericardial morphology. There was adequate scar formation between the interface of atrial lead and the epimyocardial
3

Estudo da segurança e da estabilidade do implante de cabo-eletrodo atrial direito pela via epidemiocárdiaca através do seio transverso em modelo animal suíno / Evaluation of safety and stability of right atrial lead implantation by epimyocardial access through the transverse sinus in a swine model

Sávia Christina Pereira Bueno 13 June 2013 (has links)
Introdução: Embora o implante de marcapasso atrioventricular pela via endovenosa seja considerado o estado da arte, situações clínicas e técnicas que podem impossibilitar o implante transvenoso de cabos-eletrodos têm sido cada vez mais frequentes, tornando-se necessária a proposição de abordagens cirúrgicas alternativas. Objetivos: O presente estudo visou o implante de marcapasso atrioventricular utilizando nova técnica para implante de cabo-eletrodo atrial no átrio direito, com o objetivo de avaliar no período intra-operatório e nos 30 primeiros dias de seguimento: a segurança e a reprodutibilidade do procedimento cirúrgico; a taxa de deslocamento dos cabos-eletrodos; as condições de estimulação e sensibilidade; as alterações morfológicas na cavidade pericárdica e as alterações histopatológicas epimiocárdicas. Métodos: Sob anestesia geral, foram operados 10 porcos adultos da raça Large White. Os cabos-eletrodos foram implantados, sob visão direta, no ventrículo esquerdo e no átrio direito, pelo seio transverso, através de toracotomia anterolateral esquerda. As condições de estimulação e de sensibilidade para os cabos-eletrodos atrial e ventricular, nas configurações unipolar e bipolar, foram avaliadas no intra-operatório, pós-operatório imediato, no 7º e 30º dias de pós-operatório. Ao final do estudo, os animais foram reoperados por toracotomia longitudinal mediana para observação das aderências pericárdicas e análise das condições histopatológicas da junção entre o cabo-eletrodo e o epimiocárdico. Resultados: Todos os animais permaneceram vivos até o último dia do estudo, não tendo ocorrido complicações intra-operatórias graves. As condições de estimulação e sensibilidade para os cabos-eletrodos atriais e ventriculares, nas configurações unipolar e bipolar, mantiveram-se estáveis ao longo do estudo e apresentaram comportamento semelhante. Notou-se aumento progressivo dos limiares atriais, variando de 0,50 ± 0,38 a 1,86 ± 1,31 volts nos períodos intra-operatório e 30o pós-operatório, respectivamente. Comportamento semelhante foi observado para os limiares ventriculares, que variaram de 0,43 ± 0,23 volts, no intra-operatório, a 1,22 ± 0,49 volts, no 30o pós-operatório. As medidas de impedância atrial e ventricular apresentaram uma discreta queda ao longo do tempo, sendo que a impedância atrial variou de 486,80 ± 126,35 a 385,0 ± 80,52 Ohms no período intra-operatório e 30o pós-operatório, respectivamente. A impedância ventricular variou de 700,40 ± 203,67 Ohms, no intra-operatório, a 409,30 ± 58,96 Ohms, no 30o pós-operatório. A sensibilidade, tanto em átrio quanto em ventrículo, mostrou-se estável a partir do pós-operatório imediato. A inspeção da cavidade pericárdica mostrou aderências em todos os animais e em todas as regiões avaliadas, não sendo observados derrame ou constrição pericárdica. A análise microscópica mostrou que o contato com os cabos-eletrodos provocou espessamento do epimiocárdio no átrio direito, ventrículo esquerdo e na artéria pulmonar. A cicatriz formada na junção entre o cabo-eletrodo e o epimiocárdio atrial foi semelhante à formada na região do implante dos cabos-eletrodos ventriculares. Conclusões: O implante do cabo-eletrodo atrial direito pelo seio transverso foi seguro e reprodutível. A efetividade do procedimento foi confirmada pelas condições estáveis de estimulação e de sensibilidade durante o período de seguimento pós-operatório. A única alteração morfológica encontrada na cavidade pericárdica foi a formação de aderências. Ocorreu adequada cicatrização na junção entre o cabo eletrodo e o epimiocárdio atrial / Introduction: Although transvenous access for atrioventricular pacemaker implantation is considered the state of the art, clinical and technical situations that may impede transvenous leads implantation have become increasingly common, making it necessary the proposal of new surgical approaches. Objectives: The present study was design to perform the implant of atrioventricular pacemaker using a new technique for placement of the atrial lead in the right atrium, aiming to evaluate in the intraoperative period and during the first 30 days of follow-up: the safety and reproducibility of the surgical procedure; lead dislodgment rate; conditions of pacing and sensing; morphological changes in the pericardium, as well as, histopathological changes in the epimyocardium. Methods: A total of 10 Large White adult pigs underwent pacemaker implantation under general anesthesia. By using an anterolateral thoracotomy, leads were implanted under visual guidance in the left ventricle and in the right atrium through the transverse sinus. Pacing and sensing parameters, in unipolar and bipolar modes, were obtained during the intraoperative and immediate postoperative period and on the 7th and the 30th postoperative day. At the end of the study, all animals underwent reoperation by thoracotomy through a median longitudinal sternotomy for evaluation of pericardial adhesions and histopathological analysis of the junction between the lead and epimyocardial wall. Results: All animals were alive until the end of the study and there were no serious intraoperative complications. Pacing and sensing parameters for atrial and ventricular leads in both unipolar and bipolar modes remain stable throughout the study and showed similar performance. We observed a progressive increase in atrial thresholds, ranging from 0.50 ± 0.38 to 1.86 ± 1.31 volts, during the intraoperative and on the 30-day postoperative, respectively. Similar result was observed for ventricular thresholds, which ranged from 0.43 ± 0.23 volts, intraoperatively, to 1.22 ± 0.49 volts on the 30-day postoperative. Atrial and ventricular impedance measurements decreased slightly over time, and the atrial impedance ranged from 486.80 ± 126.35 to 385.0 ± 80.52 Ohms during the intraoperative and on the 30-day postoperative, respectively. Ventricular impedance ranged from 700.40 ± 203.67 Ohms, intraoperatively, to 409.30 ± 58.96 Ohms, on the 30-day postoperative. Both atrial and ventricular sensing measurements remain stable since the immediate postoperative period. Pericardial adhesions were found in all animals and in all studied regions. There was no noticeable pericardial effusion or myocardial constriction. Microscopic analysis showed that contact with the electrode had caused thickening of the right atrium, left ventricle and pulmonary artery. Similar scar formation was found at the interface between atrial lead and epimyocardial, such as ventricular lead and epimyocardial. Conclusion: Implantation of the right atrial lead through the transverse sinus was safe and reproducible. The effectiveness of the procedure was confirmed by stable conditions of pacing and sensing parameters throughout the postoperative follow-up. Pericardial adhesion was the only change found in the pericardial morphology. There was adequate scar formation between the interface of atrial lead and the epimyocardial
4

Avaliação do trauma intracoclear causado pela inserção do feixe de eletrodos do implante coclear via janela redonda em ossos temporais / Assessment of intracochlear trauma caused by insertion of cochlear implant electrode array via round window in temporal bones

Martins, Graziela de Souza Queiroz 12 May 2014 (has links)
INTRODUÇÃO: A ampliação dos critérios de indicação para cirurgia do implante coclear e os benefícios da preservação da audição residual no pósoperatório estimularam o desenvolvimento de técnicas cirúrgicas atraumáticas. Minimizar os traumas intracocleares durante a inserção do feixe de eletrodos do implante coclear é um passo fundamental para este intuito. O objetivo deste trabalho é avaliar se o trauma intracoclear é diferente quando o feixe de eletrodos do implante coclear é inserido através do quadrante anterossuperior ou anteroinferior da membrana da janela redonda. MÉTODOS: Vinte e cinco ossos temporais frescos de cadáveres humanos foram submetidos à timpanomastoidectomia padrão. Após exposição adequada da membrana da janela redonda, em metade dos ossos o feixe de eletrodos do implante coclear foi inserido via quadrante anterossuperior da membrana da janela redonda, e na outra metade via quadrante anteroinferior. Os ossos temporais foram desidratados e embebidos em epóxi, com o feixe de eletrodos in situ. As peças foram serialmente polidas, tingidas e visualizadas por meio de estereomicroscópio para avaliar o trauma intracoclear causado pela inserção do feixe de eletrodos. As imagens foram fotografadas. RESULTADOS: Em treze ossos temporais o feixe de eletrodos do implante coclear foi inserido via quadrante anterossuperior da membrana da janela redonda, e em doze ossos via quadrante anteroinferior. Obteve-se 372 superfícies. As análises histológicas revelaram diferentes graus de traumas às estruturas intracocleares. Os resultados mostraram que a inserção do feixe de eletrodos via quadrante anterossuperior ou anteroinferior acarretam a mesma frequência de trauma intracoclear. CONCLUSÕES: A presença de trauma intracoclear e a severidade dos traumas ocorridos no tocante à inserção do feixe de eletrodos de implante coclear pelo quadrante anterossuperior e anteroinferior da membrana da janela redonda não apresentou diferença estatisticamente significativa. Observou-se, porém, maior facilidade para exposição cirúrgica do quadrante anterossuperior em relação ao quadrante anteroinferior / INTRODUCTION: The expansion of the indication criteria for cochlear implant surgery and the benefits of preserving residual hearing postoperatively have stimulated the development of atraumatic surgeries. Minimizing the intracochlear traumas during the electrodes insertion is a critical step for this aim. The objective of this study is to assess whether there is a difference in intracochlear trauma when the cochlear implant electrode array is inserted through the anterior-superior or anterior-inferior quadrants of the round window membrane. METHODS: Twenty-five fresh human temporal bones were submitted to standard tympanomastoidectomy. After adequate exposure of the round window membrane, in half of the bones the cochlear implant electrode array was inserted via anterior-superior quadrant of round window membrane and in the other half via anterior-inferior quadrant. The temporal bones were dehydrated and embedded in epoxy with the electrodes array in situ. The specimens were serially polished, stained and viewed through a stereomicroscope to assess the intracochlear trauma caused by insertion of the electrode array. Resulting images were documented. RESULTS: In thirteen temporal bones the cochlear implant electrode array was inserted via anterior-superior quadrant of round window membrane and in twelve bones via anterior-inferior quadrant. Three hundred and seventy two surfaces were obtained. Histological examinations revealed varying degrees of damage to the intracohlear structures. The results showed that the insertion of the electrode array via anterior-superior or anterior-inferior quadrant lead to the same frequency of intracochlear trauma. CONCLUSIONS: The presence of intracochlear trauma and severity of traumas regarding the insertion of cochlear implant electrode array via anterior-superior and via anterior-inferior quadrant of the round window membrane showed no statistically significant difference. However, it was observed that surgical exposure of anterior-superior quadrant was easier than surgical exposure of anterior-inferior quadrant
5

Avaliação do trauma intracoclear causado pela inserção do feixe de eletrodos do implante coclear via janela redonda em ossos temporais / Assessment of intracochlear trauma caused by insertion of cochlear implant electrode array via round window in temporal bones

Graziela de Souza Queiroz Martins 12 May 2014 (has links)
INTRODUÇÃO: A ampliação dos critérios de indicação para cirurgia do implante coclear e os benefícios da preservação da audição residual no pósoperatório estimularam o desenvolvimento de técnicas cirúrgicas atraumáticas. Minimizar os traumas intracocleares durante a inserção do feixe de eletrodos do implante coclear é um passo fundamental para este intuito. O objetivo deste trabalho é avaliar se o trauma intracoclear é diferente quando o feixe de eletrodos do implante coclear é inserido através do quadrante anterossuperior ou anteroinferior da membrana da janela redonda. MÉTODOS: Vinte e cinco ossos temporais frescos de cadáveres humanos foram submetidos à timpanomastoidectomia padrão. Após exposição adequada da membrana da janela redonda, em metade dos ossos o feixe de eletrodos do implante coclear foi inserido via quadrante anterossuperior da membrana da janela redonda, e na outra metade via quadrante anteroinferior. Os ossos temporais foram desidratados e embebidos em epóxi, com o feixe de eletrodos in situ. As peças foram serialmente polidas, tingidas e visualizadas por meio de estereomicroscópio para avaliar o trauma intracoclear causado pela inserção do feixe de eletrodos. As imagens foram fotografadas. RESULTADOS: Em treze ossos temporais o feixe de eletrodos do implante coclear foi inserido via quadrante anterossuperior da membrana da janela redonda, e em doze ossos via quadrante anteroinferior. Obteve-se 372 superfícies. As análises histológicas revelaram diferentes graus de traumas às estruturas intracocleares. Os resultados mostraram que a inserção do feixe de eletrodos via quadrante anterossuperior ou anteroinferior acarretam a mesma frequência de trauma intracoclear. CONCLUSÕES: A presença de trauma intracoclear e a severidade dos traumas ocorridos no tocante à inserção do feixe de eletrodos de implante coclear pelo quadrante anterossuperior e anteroinferior da membrana da janela redonda não apresentou diferença estatisticamente significativa. Observou-se, porém, maior facilidade para exposição cirúrgica do quadrante anterossuperior em relação ao quadrante anteroinferior / INTRODUCTION: The expansion of the indication criteria for cochlear implant surgery and the benefits of preserving residual hearing postoperatively have stimulated the development of atraumatic surgeries. Minimizing the intracochlear traumas during the electrodes insertion is a critical step for this aim. The objective of this study is to assess whether there is a difference in intracochlear trauma when the cochlear implant electrode array is inserted through the anterior-superior or anterior-inferior quadrants of the round window membrane. METHODS: Twenty-five fresh human temporal bones were submitted to standard tympanomastoidectomy. After adequate exposure of the round window membrane, in half of the bones the cochlear implant electrode array was inserted via anterior-superior quadrant of round window membrane and in the other half via anterior-inferior quadrant. The temporal bones were dehydrated and embedded in epoxy with the electrodes array in situ. The specimens were serially polished, stained and viewed through a stereomicroscope to assess the intracochlear trauma caused by insertion of the electrode array. Resulting images were documented. RESULTS: In thirteen temporal bones the cochlear implant electrode array was inserted via anterior-superior quadrant of round window membrane and in twelve bones via anterior-inferior quadrant. Three hundred and seventy two surfaces were obtained. Histological examinations revealed varying degrees of damage to the intracohlear structures. The results showed that the insertion of the electrode array via anterior-superior or anterior-inferior quadrant lead to the same frequency of intracochlear trauma. CONCLUSIONS: The presence of intracochlear trauma and severity of traumas regarding the insertion of cochlear implant electrode array via anterior-superior and via anterior-inferior quadrant of the round window membrane showed no statistically significant difference. However, it was observed that surgical exposure of anterior-superior quadrant was easier than surgical exposure of anterior-inferior quadrant

Page generated in 0.1072 seconds