• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 569
  • 15
  • 15
  • 14
  • 14
  • 10
  • 7
  • 3
  • 3
  • 3
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 582
  • 582
  • 576
  • 291
  • 283
  • 269
  • 66
  • 66
  • 63
  • 63
  • 57
  • 55
  • 51
  • 51
  • 50
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
121

Avaliação da micromorfologia da interface adesiva composta por diferentes tipos de sistemas

COSTA, Daene Patrícia Tenório Salvador da 31 January 2009 (has links)
Made available in DSpace on 2014-06-12T22:58:26Z (GMT). No. of bitstreams: 2 arquivo4058_1.pdf: 7946496 bytes, checksum: a9fd143f8820a5f21e28b5028c89eff7 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2009 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Este estudo objetivou verificar a relação entre diferentes composições de sistemas adesivos convencionais ou autocondicionantes e a qualidade da interface adesiva alcançada. Foram obtidos 50 discos dentários a partir de terceiros molares humanos extraídos, os quais foram divididos em 10 grupos. A técnica de condicionamento total foi usada em 6 grupos, seguida dos adesivos One Coat Bond SL (Coltène Whaledent), AdperTM Single Bond 2 (3M/ESPE), Master Bond (Biodinâmica), XP Bond (Dentsply), Stae (SDI) e Prime & Bond® NT (Dentsply). Nos demais grupos foram utilizados 4 adesivos autocondicionantes: AdperTM PromptTM (3M/ESPE), AdheSE (Ivoclar Vivadent), Go! (SDI) e Clearfil SE Bond (Kuraray Medical). Cada adesivo recebeu dois incrementos de 1 mm de resina composta e, após 24h em água destilada, os discos foram seccionados para análise em MEV. Os adesivos autocondicionantes apresentaram menores valores de tamanho dos tags quando comparados aos adesivos convencionais, em especial na presença de partículas de carga; formaram camadas híbridas mais espessas com os que possuíam acidez forte ou acetona na sua composição; e ainda, foi encontrado menor número e comprimento de tags no adesivo autocondicionante à base de água e maior pH. Em relação aos adesivos convencionais não houve influência da adição de partículas de carga na qualidade da interface adesiva, nem do tipo de solvente, exceto quando utilizado o butanol terciário, que propiciou a menor formação de número e comprimento de tags
122

Estudos dos efeitos do preparo sonico e ultra-sonico de cavidades retrogradas em dentes recem extraidos : analise de replicas com microscopio eletronico de varredura

Gondim Junior, Eudes 12 February 1999 (has links)
Orientador: Francisco Jose de Souza Filho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-25T20:14:41Z (GMT). No. of bitstreams: 1 GondimJunior_Eudes_M.pdf: 15092413 bytes, checksum: 3f9169afbcc9508c7640e8b12602e3e8 (MD5) Previous issue date: 1999 / Resumo: A nova geração de instrumentos sônicos e ultra sônicos desenvolvidas para o preparo de cavidades retrógradas vem tomando os preparos mais conservadores, profundos e alinhados ao longo eixo do canal radicular. Entretanto, estudos "in vitro" mostram o aparecimento de ranhuras e microfraturas nas superfícies seccionadas submetidas a estes tratamentos. O possível aparecimento de microfraturas em ápices estreitos e frágeis devido a ação vibratória destes sistemas é preocupante. Os objetivos deste estudo foram: avaliar a integridade das superfícies apicaisseccionadas depois da utilização de pontas sônicas e ultra-sônicas para preparos retrógrados; determinar se estruturas radiculares mais finas e pequenas são mais susceptíveis a ação destes instrumentos; comparar quantitativamente a qualidade das cavidades retrógradas. Cinco grupos formados por 16 dente~ anteriores humanos recém extraídos divididos por tipos de dentes e por tamanhos (pequenos e grandes) foram preparados das seguintes formas: tratamento 1- apicectomia e preparo ultra-sônico retrógrado com pontas' KIS; tratamento 2- apicectomia e preparo ultra-sônico retrógrado com as pontas Satelec S-12 (sem diamante); tratamento 3 apicectomia e preparo com o sistema sônico Sonicflex e pontas diamantadas; tratamento 4- apicectomia e preparo ultra-sônico retrógrado com pontas Satelec S-12D (diamantadas). Répiicas das superfícies apicais seccionadas pré e pós-operatórias foram feitas através de moldagens de siloxano. Com o auxílio de um programa de análise de imagens, as imagens das réplicas feitas com um microscópio eletrônico de varredura foram avaliadas com relação às dimensões e a presença de microfraturas ou ranhuras. Os resultados mostraram não haver diferenças estatisticamente significativas em relação à presença de microfraturas ou ranhuras entre os tipos de dente, tratamentos e tamanho das raízes (p>O,05). O tratamento 3 produziu as cavidades menos conservadoras quando comparado aos outros tratamentos, tomando desaconselhável sua utilização em raízes pequenas como as dos incisivos inferiores / Abstract: The new generation of sonic and ultrasonic root-end preparation devices has simplified the rreparation of conservative and sufficiently deep cavities that follow the original path of the root canal. However, "in vitro" studies have demonstrated microfractures and marginal chipping in resected roots after the use of such instruments. The occasional appearance of lines of infraction when vibratory action of sonic and ultrasonic instruments are applied on narrow or more fragile apices raised some concem. The purposes of this study were: to evaluate the integrity of resected root-end surfaces after using sonic and ultrasonic tips for retrograde preparation; to determine if finer and smaller roots are more susceptible to sonic and ultrasonic vibratory action; to compare quantitatively the quality of the root-end cavities. Five groups of 16 freshly extracted hurnan anterior teeth divided by anatomic group and size (small or big) were prepare.d as follows: treatment 1 - root-end resection and root-end cavity preparation with KIS ultrasonic retrotips; treatment 2 - resection and preparation with Satelec S-12 (no I diamond coated) ultrasonic retrotips; treatment 3- resection and preparation with a diamond-coated retrotip driven by a sonic device; treatment 4- resection and preparation with Satelec S-12D (diamond coated) ultrasonic retrotips. The resected pre-operative and postoperative root surfaces were replicated with polyvinylsiloxane impressions. With the aid of image processing and analysis system, the replicas were inspected under a Scanning electron microscope for further evaluation of shape quality and presence of cracks and marginal chipping. The results showed no significant difference in cracking or chipping amongst anatomic groups, treatments and tooth size (p>O.05). Treatment 3 produced less conservative cavities than the other three treatments and should not be used on small teeth as lower incisors / Mestrado / Endodontia / Mestre em Clínica Odontológica
123

Alteração microestrutural do fio de aço inoxidavel 316L, apos deformação e implante no tecido muscular de rato : estudo macroscopico, metalografico e microscopia eletronica de varredura

Barbeiro, Roberto Henrique 14 February 1992 (has links)
Orientador: Oslei Paes de Almeida / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-14T02:20:35Z (GMT). No. of bitstreams: 1 Barbeiro_RobertoHenrique_M.pdf: 2832700 bytes, checksum: c90c6d483e8548f369fab1e7a3468945 (MD5) Previous issue date: 1991 / Resumo: O fio de aço inoxidável 316L reto ou deformado por torção, foi analisado através de lupa estereoscópica, mi croscopia eletrônica de varredura CMEV) e metalografia. A torção ampliou as linhas de segregação, deformou a superficie e gerou tensão na estrutura interna. Após implantação em tecido muscular de rato, o fio torcido apresentou falta de coesão entre os grãos e perda de grãos formando fendas. sugerindo corrosão após 120 dias de i mpl antação. Apesar das irregularidades do fio, os aspectos histopatológicos da região do implante confirmaram que o fio de aço 316L tem boa biocompatibilidade / Abstract: Stainless steel 316L wire, straight or deformed by torsion, was analysed through a stereoscopic microscope. scanning electron microscope and metallography. Torsion enhanced segregation lines, deformed the surface and generated tension in the internal structure. After implantation in rat muscle, the twisted wire presented lack of cohesion between metal grains, as well as loss of grains, resulting in clefts. Those observations suggested corrosion after 120 days. Although the wira presented irregularities, the histopathological results confirmed the fact that the 316L stainless steel wire is highly biocompatible / Mestrado / Biologia e Patologia Buco-Dental / Mestre em Ciências
124

Efeito das tecnologias alternativas para preparo cavitario nos procedimentos adesivos com sistemas autocondicionates

Oliveira, Marcelo Tavares de 25 February 2005 (has links)
Orientadores: Marcelo Giannini, Simonides Consani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-04T03:24:00Z (GMT). No. of bitstreams: 1 Oliveira_MarceloTavaresde_M.pdf: 5082541 bytes, checksum: c0624f8aeb1f1de12e33ab3c2ce83f13 (MD5) Previous issue date: 2005 / Resumo: O objetivo deste estudo foi avaliar o efeito de técnicas de preparo cavitário nos procedimentos adesivos com sistemas autocondicionantes. Foram analisadas as resistências à tração da união após os tratamentos, assim como, em microscopia eletrônica de varredura (MEV), as características morfológicas das estruturas formadas na região da união dentina-compósito; a morfologia da superfície produzida pelos tratamentos utilizados para preparar a dentina e o padrão de fratura dos espécimes testados no ensaio de microtração. Foram utilizados 208 terceiros molares humanos, que tiveram a superfície oclusal removida para a exposição de dentina de profundidade superficial e foram divididos aleatoriamente em 32 grupos experimentais. As tecnologias de preparo cavitário foram: ausência de smear layer, abrasionamento com lixas de SiC 600, ponta diamantada (100µm),broca carboneto de tungstênio (10 lâminas), aplicação de jato de óxido de alumínio 271µm,aplicação de laser Er:YAG, ponta diamantada CVD em ultra-som e Carisolv®.Após o tratamento superficial foi aplicado um dos sistemas adesivos de acordo com as instruções dos fabricantes (Tyrian, Clearfil SE Bond, Unifil Bond e Single Bond), em seguida restaurados com o compósito Clearfil AP-X. Os dentes foram armazenados em água destilada a 3rC durante 24 horas. Após esse período, os dentes foram seccionados perpedicularmente a interface de união, nos sentidos mésio-distal e vestíbulo-lingual, com a finalidade de se obter palitos com área de secção transversal de 0,7mm2. Os espécimes foram testados com o ensaio de microtração numa velocidade de 0,5mm/min até a ruptura. Os resultados foram analisados com ANOVA dois-critérios e teste Tukey. Foi identificada uma interação entre os tratamentos e os sistemas adesivos (p<0,00003).O tratamento com o laser de Er:YAG na condição do experimento e a ponta diamantada CVD em ultra-som apresentaram os piores resultados para todos os sistemas. O Carisolv® apresentou valores de resistência de união intermediários, porém os adesivos autocondicionantes mostraram resultados inferiores ao Single Bond. A ponta diamantada, a broca carboneto de tungstênio e a lixa de SiC 600 mostraram os resultados semelhantes. A abrasão a ar proporcionou maiores valores de resistência de união para o Clearfil SE Bond que apresentou resultado superior ao Tyrian. Os sistemas Clearfil SE Bond e Single Bond foram superiores, obtendo os maiores valores na ausência de smear layer, no entanto, o Unifil Bond foi semelhante ao Single Bond. As análises em MEV revelaram variações na formação da camada híbrida e uma predominância do padrão de fratura com falha adesiva entre o sistema de união e a dentina, e parcialmente coesiva no sistema de união. Foi observado que existe uma forte dependência entre as tecnologias utilizadas para a realização dos preparos cavitários e os sistemas de união, porém a técnica do condicionamento com ácido fosfórico pode reduzir o efeito das tecnologias sobre a resistência de união, exceto pela aplicação do laser de Er:YAG e da ponta diamantada CVD em ultra-som / Abstract: The aim of this study was to evaluate the effect of alternative cavity preparation techniques on the adhesive procedures with self-etching adhesive systems. Microtensile bond strength tests (µTBS), as well as, analysis under scanning electron microscope (SEM) of the morphological characteristics of the bonded structures, treated dentin surfaces and the failure mode of the tested specimens were performed. 208 third human molars had their oclusal surface flattened in order to expose superficial dentin. Teeth were randomly assigned to 32 experimental groups. Cavity preparation techniques used in this study were: smear layer free surface, 600-grit SiC paper, diamond bur (100µm,)carbide bur (10 blades), air abrasion, Er:YAG laser, CVD diamond bur - sonoabrasion and Carisolv® gel. Following each surface treatment, adhesive systems (Tyrian, Clearfil SE Bond, Unifil Bond and Single Bond) were applied according to manufacturer's instructions and 6mm high blocks were incrementally built up with Clearfil AP-X (Kuraray) composite resin. The specimens were stored for 24 hours at 37°C in distilled water and were serially sectioned in both mesio-distal and buccal-lingual directions transversally to the bonded interface to obtain an array of bonded beams with a cross-sectional area of 0.7mm2. Beams were tested in tension (0.5mm/min - Instron 4411) and results were analyzed with two-way ANOVA and Tukey's test. It was found an interaction between adhesive systems and surface treatments (p<0.00003). Sonoabrasion and laser treatment yielded the lowest values for the tested adhesive systems; Carisolv® gel showed intermediate bond strength, however, self-etching adhesive systems were worse than Single Bond. Diamond bur, carbide bur and 600-grit SiC paper had similar results. Air-abrasion produced improved results for adhesion with Clearfil SE Bond that was significantly better than Tyrian. Clearfil SE Bond and Single Bond were superior, obtaining the highest values of The aim of this study was to evaluate the effect of alternative cavity preparation techniques on the adhesive procedures with self-etching adhesive systems. Microtensile bond strength tests (µTBS), as well as, analysis under scanning electron microscope (SEM) of the morphological characteristics of the bonded structures, treated dentin surfaces and the failure mode of the tested specimens were performed. 208 third human molars had their oclusal surface flattened in order to expose superficial dentin. Teeth were randomly assigned to 32 experimental groups. Cavity preparation techniques used in this study were: smear layer free surface, 600-grit SiC paper, diamond bur (100µm,)carbide bur (10 blades), air abrasion, Er:YAG laser, CVD diamond bur - sonoabrasion and Carisolv®gel. Following each surface treatment, adhesive systems (Tyrian, Clearfil SE Bond, Unifil Bond and Single Bond) were applied according to manufacturer's instructions and 6mm high blocks were incrementally built up with Clearfil AP-X (Kuraray) composite resin. The specimens were stored for 24 hours at 37°C in distilled water and were serially sectioned in both mesio-distal and buccal-lingual directions transversally to the bonded interface to obtain an array of bonded beams with a cross-sectional area of O.7mm2. Beams were tested in tension (0.5mm/min - Instron 4411) and results were analyzed with two-way ANOVA and Tukey's test. It was found an interaction between adhesive systems and surface treatments (p<0.00003). Sonoabrasion and laser treatment yielded the lowest values for the tested adhesive systems; Carisolv® gel showed intermediate bond strength, however, self-etching adhesive systems were worse than Single Bond. Diamond bur, carbide bur and 600-grit SiC paper had similar results. Air-abrasion produced improved results for adhesion with Clearfil SE Bond that was significantly better than Tyrian. Clearfil SE Bond and Single Bond were superior, obtaining the highest values of µTBS for the smear layer free surface, although in the comparison among the adhesive systems Unifil Bond and Single Bond were similar. SEM analysis revealed some variations in the hybrid layer formation and the predominance of an adhesive failure between adhesive system and dentin, and partially cohesive in the adhesive system. It was also observed that there is a strong relationship between cavity preparation techniques and adhesive systems, however, the total-etch technique seems to levei the effect over the µTBS, except for the Er:YAG laser treatment and sonoabrasion / Mestrado / Dentística / Mestre em Clínica Odontológica
125

Estudo das condições de extrusão reativa e suas influencias na compatibilização e propriedades da mistura poli (tereftalato de etileno) (pet)/policarbonato (pc)

Vanin, Mirela 17 July 1998 (has links)
Orientador: Chang Tien Kiang / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Quimica / Made available in DSpace on 2018-07-23T21:00:16Z (GMT). No. of bitstreams: 1 Vanin_Mirela_M.pdf: 3476241 bytes, checksum: 953ee5c1a39639db4a8111561853cb11 (MD5) Previous issue date: 1998 / Resumo: o estudo de misturas poliméricas têm crescido bastante devido à possibilidade de se obter materiais de alta performance. Muitos são os estudos sobre a mistura Poli (tereftalato de etileno)(PET)/Policarbonato(PC) , donde se tem que, esta mistura é termodinamicamente imiscível, mas com possibilidade de se conseguir compatibilizar os polímeros quando misturados no estado fundido, devido a ocorrência de reações de transesterificação. Além disso, a eficiência destas reações podem ser influenciadas pelos parâmetros de processamento. Este trabalho visa o estudo da mistura PET/PC, objetivando combinar a alta resistência térmica e mecânica do PC, com a grande utilidade do PET como polímero de engenharia. As amostras da mistura PET/PC foram confeccionadas por extrusão reativa no estado fundido, variando parâmetros de processamento como: tempo total de processamento e de cisalhamento, concentração de componentes de mistura, emprego e concentração de catalisador e reprocessamento, no equipamento Mini Max Molder e em extrusora dupla rosca. As amostras obtidas foram caracterizadas por: Viscosidade intrínseca, notando-se a possível ocorrência de reações de degradação no emprego de catalisador; Microscopia Eletrônica de Varredura, verificando-se que o aumento do tempo total de processo e do cisalhamento contribuíram para melhorar a dispersão das fases; Infravermelho por Transformada de Fourier, donde verificou-se que a eficiência das reações de transesterificação foi aumentada com o aumento do tempo de processo e de cisalhamento; e análise mecânica, por Análise Dinâmico Mecânica que permitiu observar tendência à miscibilidade da mistura PET/PC devido ao aparecimento de uma única Tg, na análise dos resultados / Abstract: The studies on polymeric mixtures increased considerably due to the possibilities of obtaining high performance materials. Many of them are about the Poly (ethylene terephthalate) (PET)/ Polycarbonate (PC) mixture, which is thermodynamically immiscible, but potentially compatible when the polymers are mixed in the molten state due to transesterification reactions. Besides, the efficiency of these reactions can be influenced by the processing parameters. This study is aimed at studying PET/PC mixture by combining the PC high mechanical and thermal resistance and the usefulness of PET as an engineering polymer. The PET/PC mixture samples were obtained by reactive extrusion in the molten state, varying processing parameters such as: total processing time, shearing time, concentration of the mixture components, utilization of a catalyzer, catalyzer concentration and reprocessing in a Mini Max Molder equipment, as well as varying screw speed in a twin-screw co-rotating extruder. The samples obtained were characterized by: intrinsic viscosity, observing the possible degradation reactions in the utilization of the catalyzer; Scanning Electron Microscopy, verifying if the increase in the processing and shearing time contributed to improve the phase dispersion; Fourier Transformed Intrared analysis was utilized to confirm the efficiency of the transesterification reactions due to the increase in the process time and shearing time; Dynamic Mechanical Analysis showed that the PET/PC mixtures were compatibilized with the appearance of a single Tg / Mestrado / Ciencia e Tecnologia de Materiais / Mestre em Engenharia Química
126

Viabilidade e resistencia a sais biliares de Lactobacillus acidophilus de dois produtos lacteos fermentados comercializados no Brasil

Rodrigues, Maria Aparecida Martins 08 October 1993 (has links)
Orientadores : Debora de Queiroz Tavares, Celia Lucia de L. F. Ferreira / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Alimentos / Made available in DSpace on 2018-07-18T14:15:50Z (GMT). No. of bitstreams: 1 Rodrigues_MariaAparecidaMartins_M.pdf: 3362182 bytes, checksum: 258ee4f5f6e47753d1ba8478a6f7ac7e (MD5) Previous issue date: 1993 / Resumo: Os Lactobacillus acidophilus veiculados nos leites fermentados comercializados no Brasil (1) foram isolados, cultivados e quantificados. Foi também analisada a cepa CH2(2), comercializada para as firmas produtoras dos probióticos. Para efeito comparativo acrescentou-se ao estudo a cepa NCFM (3) e NCFM"L" (4) que se caracterizam pela produção de bacteriocinas e pela resistência aos sais biliares. Na contagem total em placa os L. acidophilus dos produtos novos ou armazenados mostraram sobrevivência adequada com 108 ufc/g de produto, quantidade estipulada para colonizadores intestinais. Nos testes de resistência aos sais biliares, os L. acidophilus com melhor desempenho foram os isolados do produto Biovita. No estudo ao Microscópio Optico de Fluorescência demonstrou-se que, embora os lactobacilos sobrevivessem na presença dos sais biliares, eles eram gradualmente afetados porque demonstraram perda de atividade metabólica, diminuição de diâmetro, e elongamento em cadeia das células. Sob Microscopia Eletrônica de Varredura demonstraram-se as colônias ativas e as deformações de parede oriundas possivelmente das condições experimentais impostas às células. Na Microscopia Eletrônica de Transmissão resolveram-se as questões pertinentes à. parede externa das células: as cepas não diferem morfologicamente entre si mas o tratamento com sais biliares diminuiu a extensão da camada externa das células constituída de proteínas e polissacárides as quais entre outras funções deveriam exercer o reconhecimento dos bacilos com substratos específicos. A administração de L. acidophilus oriundos de "Bio" e "Biovita" a ratos machos Wistar SPF (Specific Pathogen Free) não resultou em colonização do jejuno e íleo dos animais embora os produtos promovessem boa aceitação e ganho ponderal. (1)Refere-se aos produtos "Bio" e "Biovita" que são produtos lácteos fermentados por cultura mista de L. acidophilus, Streptococcus spp e Bifidobacterium spp. "Bio" é produto da Indústria Danone, São Paulo, S.P. e "Biovita" é produto da Indústria Nestlé, Araras, S.P. (2)CH2 é cepa comercializada pela HA-LA do Brasil Chr. Hansen Ind. & Co. Ltda. Cx. P. 371, Valinhos, S.P. (3)NCFM: Originária do Animal Science Department, Oklahoma State University, Stillwater, Oklahoma, USA, foi cedida pela Profa. Célia Lúcia de L.F.Ferreira do Departamento de Tecnologia de Alimentos da Universidade Federal de Viçosa, M.G. (4)NCFM"L": Isolada de intestino humano pela Profa. Dra. Célia L.de L.F.Ferreira / Abstract: Lactobacillus acidophilus carried in probiotic brazilian products (1) were isolated, cultivated and quantified. Another two cultures were added to analysis: CH2 a commercial culture (2), NCFM ( 3 ) and NCFM" L" (4 )a culture that produces bacteriocins and has bile salts resistance. The total count plate of L. acidophilus isolated from fresh products or during storage demonstrated a suitable value of 108 cfu/g, enough to be considered as intestinal colonizer. Biovita product beared the most resisting L. acidophilus to bile salts. Fluorescence microscopy demonstrated that the cells lost its ordinary morfology and were progressively inactived by bile salts. The morfology were analysed under Scanning Electron Microscopy: in the absense of bile salts the cells had normal partition and were turgids; distortion of cell wall ocurred otherwise. The velvet appearance of cell wall under Transmission Electron Microscopy, whose proteinglicosidic nature is considered essential to cell recognition was almost lost when bile salts were added. Biological dietary assay with Wistar SPF (Specific Pathogen Free) rats did not result in colonization of the small intestine by L. acidophilus from the commercial products. (1) "Bio" and "Biovi ta" are probiotic brazilian trade marks from Danone Ind. & Co and Nestlé respectively. (2) CH2 was obtained from HA-LA Ind. & Co of the Brazil. (3) NCFM: originated from Am.Sci.Dep., Oklahoma State University was received from Dra. Célia L.Ferreira, D.T.A., U. F. V., Viçosa, M. G. (4) NCFM"L": isolated by Profa. Dra. Célia L.L.F.Ferreira / Mestrado / Mestre em Tecnologia de Alimentos
127

Rugosidade e espalhamento em superfícies de n-InP atacada fotoeletroquimicamente

Ferreira, Neidenei Gomes 06 December 1994 (has links)
Orientador: Lucila Cescato / Tese (doutorado) - Universidade Estadual de Campinas. Instituto de Fisica Gleb Wataghin / Made available in DSpace on 2018-07-19T17:09:46Z (GMT). No. of bitstreams: 1 Ferreira_NeideneiGomes_D.pdf: 15957026 bytes, checksum: 70e8fe8694376088f253d4ccdaeb6b1f (MD5) Previous issue date: 1994 / Resumo: A evolução da textura produzida fotoeletroquimicamente em superfícies semicondutoras de n-InP (100) foi estudada utilizando várias técnicas. Este tipo de ataque forma microestruturas alongadas, que são analisadas por Microscopia Eletrônica de Varredura e medidas de Espalhamento Óptico, cuja geometria e dimensão dependem do tempo de ataque. A rugosidade gerada na superfície aumenta fortemente a absorção na amostra. Este comportamento foi observado pelas medidas de refletância total integrada e medidas de curvas I x V, utilizadas para acompanhar o aumento da fotocorrente durante o ataque fotoeletroquímico. Foi construído um sistema para medidas de espalhamento angularmente resolvido (ARS). Os espectros de ARS, associados à teoria vetorial de espalhamento, possibilitam calcular a função autocorrelação da superfície. Esta função, fornece o valor da rugosidade média (drms) das microestruturas e sua oscilação exibe as características quase-periódicas das estruturas superficiais / Abstract: The evolution of photoelectrochemically produced textures on n-InP (100) surfaces was studied by various techniques. Such etching results in the formation of elongated etch pits which were analysed using Scanning Electron Microscopy and Optical Scattering, and whose geometries and dimensions depend on the time of the attack. The reflectivity of the sample surface was found to decrease due to roughening of the surface, and this was measured using a total integrated reflection device. I x V measurements were also utilized in order to follow the increase in the photocurrent during the photoelectrochemical etching. A system for measuring angular resolved scattering was constructed. By using the vector scattering theory, the autocorrelation function was obtained. This function furnishes the route mean square roughness (drms) of the surface microstructures, and the oscillation of the function exhibts the quasi-periodic character of the surface structures / Doutorado / Física / Doutor em Ciências
128

Determinação do módulo de elasticidade a torção do Politetrafluoretileno (PTFE) utilizando espectroscopia mecânica /

Piedade, Lucas Pereira. January 2019 (has links)
Orientador: Cesar Renato Foschini / Coorientador: Carlos Alberto Fonzar Pintão / Banca: Eduardo Carlos Bianchi / Banca: Nilton Francelosi Azevedo Neto / Resumo: Materiais poliméricos são comumente usados em aplicações de engenharia, o que tem motivado pesquisadores a estudarem seu comportamento mecânico e o desenvolvimento de sistemas de medida. O Politetrafluoretileno (PTFE), comercialmente conhecido como Teflon, é um destes polímeros. Devido ao fato de que o PTFE é capaz de realizar funções estruturais específicas e ser submetido a esforços mecânicos cisalhantes, é importante que se conheça o valor do módulo de torção, G, não só para predizer seu comportamento mecânico, mas também para usá-lo como parâmetro de rigidez em projetos. Desta forma, o principal objetivo deste trabalho foi apresentar e validar o uso de uma técnica alternativa para determinar o módulo de torção, G, de materiais com ênfase em materiais poliméricos, em particular, o PTFE. Para realizar a medida de G, foi utilizado um sistema mecânico contendo um pêndulo de torção e um sensor de movimento rotativo (SMR) acoplado a ele, que permitisse determinar: a posição angular em função do tempo. Então, uma equação derivada dos estudos de espectroscopia mecânica e da teoria de relaxação foi utilizada para o cálculo de G. A técnica aplicada neste trabalho é considerada como não destrutiva e independe de se conhecer o valor do coeficiente de Poisson do material em estudo. Amostras de diferentes diâmetros de PTFE extrudado foram submetidas a esforços de torção simples variando seu comprimento efetivo, a fim de estudar o seu comportamento à torção. As amostras passaram por aná... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Polymeric materials are commonly used in engineering applications, which has motivated researchers to study their mechanical behavior and development of measurement systems. The Polytetrafluoroethylene (PTFE), commercially known as Teflon, is one of these polymers. Due the fact that PTFE is able to perform a specific structural function and be subjected to mechanical shear stresses, it is important to know the value of the torsion modulus, G, not only to predict its mechanical behavior, but also to use it as a parameter of rigidity in projects. In this way, the main objective of this work was to present and validate the use of an alternative technique to determine the torsion modulus, G, of materials with emphasis on polymeric materials, in particular the PTFE. For this purpose, a mechanical system containing a torsion pendulum and a rotational motion sensor (RMS) coupled to it was used to determine the angular position as a function of time. Then, an equation derived from mechanical spectroscopy and relaxation theory was used for the calculation of G. The technique applied in this work is considered as non-destructive and is independent of knowing the value of Poisson's ratio of a study material. Samples with different diameters of extruded PTFE were subjected to simple torsional stresses varying their effective length in order to study their torsional behavior. The samples were subjected to thermal analysis to determine their degree of purity, thermal stability and to estim... (Complete abstract click electronic access below) / Mestre
129

Crescimento de cristais nanoestruturados baseados em óxidos de antimônio /

Barros, Herick Ematne da Silva. January 2019 (has links)
Orientador: Olivia Maria Berengue / Banca: Eduardo Gonçalves Ciapina / Banca: Erica Freire Antunes / Resumo: Neste trabalho foram desenvolvidas rotas de crescimento de micro- e nanoestruturas de Sb2O3 e Sb2O4 através de métodos de deposição de fase vapor. Para análise das amostras obtidas foram utilizadas técnicas de difratometria de raios-X, microscopia eletrônica de varredura e espectroscopia Raman. A análise dos resultados obtidos permitiu identificar corretamente as algumas das características estruturais e morfológicas das amostras bem como definir uma rota de crescimento de qualidade e reprodutibilidade. Após a produção e caracterização das amostras dos óxidos de antimônio foi feita a funcionalização e decoração superficial das nanoestruturas de Sb2O3 com nanopartículas de paládio. As nanoestruturas funcionalizadas foram devidamente caracterizadas pelas mesmas técnicas aplicadas as amostras puras dos óxidos, com isso foi possível verificar a eficácia do processo de decoração superficial bem como obter informações sobre a estrutura do produto final desse processo. A síntese de Sb2O3 gerou amostras com 3 tipos de morfologias diferentes, a primeira possui fase cristalina ortorrômbica e consiste de micro e nanofitas ramificadas, as outras duas morfologias são constituídas por seguimentos de micro octaedros empilhados e aglomerados de micrestruturas octaédricas e microesferas, ambas apresentam fase cristalina cúbica. O processo de decoração superficial das amostras de Sb2O3 com nanopartículas de paládio se mostrou eficaz, porém levou a uma grande alteração na morfologia das amostra... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: In this work, Sb2O3 and Sb2O4 micro- and nanostructures were synthesized by a vapor phase deposition method. Aiming to provide data on the structure of these samples, Xray diffraction, scanning electron microscopy and Raman spectroscopy techniques were used. The data analysis allowed to correctly identify the characteristics of the samples as well as to define a good and reproductible growth process. The as-grown Sb2O3 was submitted to palladium nanoparticles functionalization and superficial decoration process. The functionalized nanostructures were duly characterized by the same techniques applied to the pure oxide samples, with the purpose of verifying the effectiveness of the surface decoration process as well as obtaining information on the structure. The Sb2O3 synthesis provide 3 types of different morphologies, the first one has an orthorhombic crystalline phase and consists of branched micro and nanobelts, the other two morphologies are followed by stacked micro octahedron and agglomerate of octahedrons and sphere microstructures, both morphologies have orthorhombic crystalline phase. The palladium nanoparticles functionalization and superficial decoration process proved to be effective, but led to a great morphology change of the Sb2O3 samples. The as-grown Sb2O4 are mainly composed by micro- and nanowires mixed with branched micro-belts structures, both morphologies have orthorhombic crystalline phase / Mestre
130

Avaliação morfológica e molecular do gênero Xiphopenaeus no Atlântico Ocidental e Pacifico existe apenas uma espécie? /

Carvalho-Batista, Abner. January 2017 (has links)
Orientador: Rogério Caetanos da Costa / Coorientador: Mariana Terossi Rodrigues Mariano / Resumo: Espécies crípticas constituem um desafio ao conhecimento da biodiversidade e tem sido tema de um número cada vez maior de estudos nos últimos anos. O gênero Xiphopenaeus por 90 anos teve reconhecidamente duas espécies, Xiphopenaeus kroyeri no Atlântico e Xiphopenaeus riveti, no Pacífico. Contudo, nos últimos 20 anos, a taxonomia do gênero tem passado por grandes reviravoltas, com a sinonimização das duas espécies em 1997 com base em dados morfológicos, tornando o gênero monotípico, com X. kroyeri como a única espécie válida. E nos últimos dez anos além da revalidação de X. riveti baseada em dados moleculares, a existência de na verdade, duas espécies crípticas no Atlântico, veio a tona. Assim, o presente estudo averiguou utilizando ferramentas moleculares (os genes mitocondriais Citocromo c Oxidase Subunidade I e 16S rDNA) e morfológicas, o possível número de espécies constituintes do gênero Xiphopenaeus, e quais caracteres morfológicos podem ser utilizados na identificação destas. Foram analisados indivíduos provenientes de 16 localidades nos oceanos Atlântico e Pacífico. Foi detectada a divisão dos indivíduos analisados em cinco grupos, três no Atlântico, aqui denominadas a principio de A1, A2 e A3 e dois no Pacífico, P1 e P2, os quais pelas divergências genéticas observadas em ambos os marcadores empregados, mostraram-se constituir cinco diferentes espécies. Tal divisão foi suportada pelas demais análises empregadas (análises filogenéticas, Amova, rede de haplótipos). As f... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Cryptic species comprise a challenge to the knowledge of biodiversity, and they have been increasingly studied in past recent years. For 90 years, the genus Xiphopenaeus had recognized two species: Xiphopenaeus kroyeri, in the Atlantic, and Xiphopenaeus riveti, in the Pacific. In the last 20 years, however, the taxonomy of the genus has been changed; the synonymization of the species in 1997, based on morphological characters, turned the genus monotypic, with X. kroyeri as the only valid species. In the last decade, besides the revalidation of X. riveti based on molecular data, the existence of two cryptic species in the Atlantic came to light. Thus, the present study aimed to verify, using molecular (the mitochondrial genes Cytochrome Oxidase Subunit I and 16S rDNA) and morphological tools, how many species comprise the genus Xiphopenaeus, and which morphological characters can be used for their reliable identification. Individuals from 16 localities in Atlantic and Pacific oceans were analyzed. A structuration of the analyzed individuals into five groups was observed, three from the Atlantic (A1, A2 and A3) and two from the Pacific (P1 and P2). The genetic divergence observed indicates the existence of five different species. Such structuration was also supported by the phylogenetic analyzes, AMOVA and haplotype network. The images obtained by scanning electronic microscopy of secondary sexual characters of males showed morphological differences reliable enough to discrimin... (Complete abstract click electronic access below) / Doutor

Page generated in 0.0751 seconds