• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 569
  • 15
  • 15
  • 14
  • 14
  • 10
  • 7
  • 3
  • 3
  • 3
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 582
  • 582
  • 576
  • 291
  • 283
  • 269
  • 66
  • 66
  • 63
  • 63
  • 57
  • 55
  • 51
  • 51
  • 50
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
131

Comparação dos efeitos do diuron formulado e técnico no urotélio e nos parâmetros reprodutivos de ratos wistar machos

Sales, Bianca Camargo Penteado January 2018 (has links)
Orientador: Maria Luiza Cotrim Sartor de Oliveira / Resumo: Ratos Wistar expostos por dois anos ao diuron (3-(3,4-diclorofenil)-1,1-dimetilureia) produto técnico (PT) à 2500ppm pela ração desenvolveram alta incidência de tumores uroteliais, sendo esse herbicida classificado pela U.S. Environmental Protection Agency como "provável cancerígeno para o homem''. Durante a última década, nosso laboratório tem realizado estudos sobre a toxicidade urotelial do diuron PT fornecido pela ração a ratos Wistar machos. Porém, o diuron na forma de produto formulado (PF) ou comercial, composto por 50% de diuron PT e 50% de ingredientes inertes, não tem sido avaliado em ratos. Em lagartos P. sicula machos expostos ao diuron PF à 50% na concentração de 1100ppm na ração ou na água de beber, durante 3 semanas, houve toxicidade direta no sistema reprodutivo com alteração na espermatogênese, morfologia do epidídimo e diminuição dos níveis plasmáticos dos hormônios sexuais, sendo os efeitos mais severos nos grupos que receberam diuron na água de beber. O presente estudo objetivou comparar o potencial tóxico do diuron PF ou PT à 1250ppm oferecido pela ração ou água de beber no urotélio e nos parâmetros reprodutivos de ratos. Cinquenta ratos Wistar machos de seis semanas de idade foram distribuídos em cinco grupos (ração basal, ração com PF, água de beber com PF, ração com PT, água potável com PT) e expostos ao diuron à 1250ppm por 13 semanas. Na eutanásia foram avaliados a morfologia, concentração, motilidade e viabilidade dos espermatozoides. Os rins, fígad... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Wistar rats exposed during two years to 2500ppm dietary diuron technical product (TP) (3-(3,4- dichlorophenyl)-1,1-dimethylurea) developed high incidence of urothelial tumors, being classified by the U.S. Environmental Protection Agency as a ‘‘known/likely human carcinogen’’. During the last decades our laboratory conducted studies on the urothelial toxicity of the diuron (TP) provided through diet to male Wistar rats. The diuron formulated product (FP) composed by 50% diuron TP and 50% inert ingredients, has not been evaluated in rats. The diuron (FP) was harmful to reproductive system of male P. sicula lizards exposed to 1100ppm during 3 weeks; the toxic effects were more prominent in the groups receiving diuron FP in drinking water. This study aimed to compare the potential toxicity of diuron TP or FP 1250ppm offered through diet or drinking water on the urothelium and reproductive parameters of rats. Fifty six-week old Wistar male rats were allocated to five groups (basal diet, FP diet, FP drinking water, TP diet, TP drinking water) and exposed to 1250ppm diuron for 13 weeks. At the end, body weight and weight of kidneys, liver, spleen, testes and epididymis, histopathology of the kidneys and testes and sperm parameters were evaluated. Urinary bladders were bisected and processed for histologic and scanning electron microscopic (SEM) analyses. At the end of the study, all groups exposed to diuron had decreased body weight gain compared to control greater than 10%, indicat... (Complete abstract click electronic access below) / Mestre
132

Influência dos tratamentos térmicos de nucleação na fração cristalina e morfologia dos cristais de dissilicato de lítio LaMaV CAD /

Vallerini, Bruna de Freitas January 2019 (has links)
Orientador: Mariana de Oliveira Carlos Villas-Bôas / Resumo: Os materiais destinados a próteses odontológicas têm evoluído ao longo dos anos permitindo chegar a materiais cerâmicos com alta qualidade, sendo o dissilicato de lítio um dos materiais mais utilizados devido à sua ampla gama de indicações; isto é possível pois sua microestrutura está diretamente relacionada com suas boas propriedades mecânicas, físicas e óticas. O Laboratório de Materiais Vítreos (LaMaV) da Universidade Federal de São Carlos está desenvolvendo um dissilicato de lítio do tipo fresado que permite obter próteses a um custo futuro mais acessível; porém, estudos ainda são necessários para otimizar a microestrutura. Sendo assim, o objetivo deste estudo foi avaliar a influência dos diferentes tratamentos térmicos de nucleação na fração cristalina e morfologia dos cristais de LaMaV CAD. Para tanto foram confeccionados discos (12 mm de diâmetro x 1,2 mm de espessura) de dissilicato de lítio LaMaV CAD e de IPS e.max CAD (grupo controle, n=3). Os discos de LaMaV CAD foram submetidos a recozimento a 380oC por 2h seguido de diferentes tratamentos térmicos de nucleação, processo no qual se variou o tempo e a temperatura compondo quatro subgrupos (n=3): T1 (1h30 por 500oC), T2 (3h por 500oC), T3 (6h por 500oC) e T4 (6h por 480oC). Os discos de IPS e.max CAD foram cristalizados de acordo com as recomendações do fabricante. Foram obtidas imagens em microscópio óptico de varredura (MEV) para caracterizar a microestrutura e quantificar a fração cristalina. Tal quantificação fo... (Resumo completo, clicar acesso eletrônico abaixo) / Mestre
133

Efeitos do fosfato ou silicato de cálcio no substrato dentinário erodido e nas propriedades do sistema adesivo autocondicionante Clearfil SE Bond /

Escalante Otárola, Wilfredo Gustavo. January 2020 (has links)
Orientador: Milton Carlos Kuga / Resumo: O objetivo do estudo foi avaliar o efeito de agentes remineralizantes à base de fosfato ou silicato de cálcio em formar precipitados e obstruir túbulos dentinários e seus efeitos sobre o colágeno da dentina erodida. Assim mesmo, avaliar seu efeito na resistência de união, formação de camada hibrida e penetrabilidade dentinária do sistema adesivo autocondicionante Clearfil SE Bond. Material e métodos: Trezentos espécimes foram obtidos do segmento cervical de incisivos bovinos e previamente submetidos à erosão dentinária. Os espécimes foram distribuídos em 5 protocolos (n=30): NP, Desensibilize NanoP; RD, MI Paste Plus RecaldentTM; NR, Regenerate NR-5TM; KF, Desensibilize KF 2% e CO, sem tratamento. Cada um dos protocolos foi aplicado no total de 4 sessões, com intervalos de 7 dias. Duzentos espécimes (n=20) foram diariamente submetidos ao desafio ácido, por imersão em suco de laranja, por 5 minutos e, posteriormente mantidos em saliva artificial. Na sequencia, cem espécimes foram analisados em microscopia eletrônica de varredura para avaliar a formação de precipitados sobre a superfície dentinária (500x) e obter o número de túbulos dentinários abertos (2,000x), e em microscopia EDX para obter resultados qualitativos sobre a composição do precitado, e avaliados por meio de microscopia de luz polarizada, com coloração picrosirius red, para qualificar a morfologia do colágeno da dentina após a conclusão do tratamento. Nos duzentos espécimes restantes (n=20), cem sem desafio ácido... (Resumo completo, clicar acesso eletrônico abaixo) / Doutor
134

Avaliação da superfície do esmalte dentário por microscopia eletrônica de varredura após a remoção do bráquete e polimento /

Pignatta, Lilian Maria Brisque. January 2006 (has links)
Orientador: Eduardo César Almada Santos / Banca: José Rino Neto / Banca: Francisco Antonio Bertoz / Resumo: Introdução: a preservação da estrutura de esmalte após a remoção dos acessórios ortodônticos é uma obrigação do clínico. Portanto, procura-se um protocolo de descolagem com bases científicas. Objetivou-se neste trabalho avaliar por Microscopia Eletrônica de Varredura (MEV) a influência de quatro protocolos de remoção de bráquetes e polimento da superfície do esmalte e propor um protocolo que minimizasse os danos na superfície do esmalte. Material e método: doze incisivos permanentes bovinos foram divididos em quatro grupos de acordo com os instrumentos utilizados para a descolagem dos bráquetes e remoção do remanescente adesivo. Os bráquetes foram descolados com o alicate de descolagem reto (Ormco Corp.) nos grupos 1 e 2, e com o instrumento de descolagem Lift-Off (3M Unitek) nos grupos 3 e 4. Os remanescentes adesivos dos grupos 1 e 3 foram removidos com o alicate removedor de resina longo (Ormco Corp.) e dos grupos 2 e 4 com broca de carboneto de tungstênio (Beavers Dental) em alta-rotação com constante refrigeração de água. As superfícies, após cada etapa da descolagem e polimento, foram avaliadas em réplicas de resina epóxica e foram obtidas eletromicrografias com aumento de 50 e 200X em todos os grupos. Resultado: os quatro protocolos de remoção de acessórios ortodônticos e polimento ocasionaram irregularidades no esmalte. Conclusão: a remoção do bráquete com o alicate de descolagem reto, seguido da remoção do remanescente adesivo com broca de carboneto de tungstênio e polimento final com pasta de pedra-pomes foi o procedimento que ocasionou menores danos ao esmalte, sendo o protocolo sugerido para a remoção dos acessórios ortodônticos. / Abstract: Introduction: the preservation of the enamel structure after the removal of the orthodontic accessories is an obligation of the clinical. Therefore, a protocol of debonding with scientific bases is searched. The aim of this work was to evaluate through Scanning Electronic Microscopy (SEM) the influence of four protocols of bracket’s removal and polishing on the enamel and to recommend a protocol that minimized the damages to the enamel surface. Methods: twelve permanent bovine incisors were divided into four groups according to the instruments used to debond and remove of adhesive remnants. The brackets were removed with straight debonding pliers (Ormco Corp.) in the groups 1 and 2, and with Lift-Off debonding instrument (3M Unitek) in the Groups 3 and 4. The adhesive remnants in the groups 1 and 3 were removed with the adhesive removing pliers (Ormco Corp.) and in the groups 2 and 4 with high speed tungsten carbide bur with constant water refrigeration (Beavers Dental). The surfaces, after each step of debonding and polishing were evaluated in replicas of epoxy resin and were obtained electromicrographies with magnification of 50 and 200X in all groups. Results: the four removal protocols of orthodontic accessories and polishing caused irregularities to the enamel. Conclusion: the bracket’s removal with straight debonding pliers, followed by the removal of the adhesive remnants with tungsten carbide bur and final polishing with pumice was the procedure that caused less damage to enamel, being the suggested protocol for removal of orthodontic accessories. / Mestre
135

Caracterização estrutural e mineral do biofilme supragengival pigmentado de bovinos com periodontite /

Saraiva, Júlia Rebecca. January 2019 (has links)
Orientador: Iveraldo dos Santos Dutra / Banca: Ana Carolina Borsanelli / Banca: Vera Lúcia Lorenzetti Magalhães Curci / Resumo: A periodontite é uma infecção multifatorial já descrita em diferentes espécies, dentre elas os ruminantes domésticos. Em bovinos, a doença relaciona-se, dentre outros fatores, a uma microbiota potencialmente patogênica que, em sua maioria, encontra-se alojada no biofilme bucal destes animais. Biofilmes são estruturas organizadas, nas quais os constituintes convivem em cooperativismo metabólico e oferecem benefícios para a sobrevivência da microbiota local. Estas formações podem ser classificadas em supragengivais ou subgengivais, e quando mineralizadas, resultam na formação do cálculo. O cálculo supragengival em bovinos é visualizado como um depósito fortemente aderido ao dente, pigmentado de marrom ou preto que no ser humano e em outras espécies já foi descrito como um fator predisponente às doenças periodontais. O objetivo do presente estudo foi caracterizar estrutural e quimicamente o biofilme supragengival de bovinos utilizando-se das técnicas de microscopia eletrônica de varredura (MEV) e espectroscopia de dispersão de energia (EDS), respectivamente, e relacionar os achados ao quadro clínico bucal dos animais (presença de periodontite). Foram coletados 11 dentes primeiro-molares de diferentes animais; cinco amostras sem pigmentação visível, e seis amostras pigmentadas de preto, que foram submetidas inicialmente a MEV, e posteriormente, foram selecionadas três áreas aleatórias para realização da EDS. Os resultados da MEV revelaram formações estruturais com presença de áre... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Periodontitis is a multifactorial infection already existing in different species, among them domestic ruminants. In bovines, this disease is related, among other factors, to a potentially pathogenic microbiota that, for the most part, is housed in the oral biofilm of the animals. Biofilms are organized structures that favor the survival of the local microbiota. Biofilms can be classified as supragingival or subgingival, and when mineralized, they form the dental calculus. The supragingival calculus in bovines is visualized as pigmented brown or black deposit, already described in humans as a predisposing factor to periodontal diseases. The aim of this study was to characterize the structural and chemical the supragingival biofilm of bovines using scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS), respectively, and to relate them to the clinical status of the animals (periodontitis). Eleven premolars teeth were collected; five non-pigmented samples, and six black pigmented samples, were initially submitted to SEM and, subsequently, to EDS. SEM images revealed irregular structures similar to mineral deposits. The EDS results showed a relation between the presence of iron (p<0,014) and magnesium (p<0,001) with the occurrence of periodontitis. Regarding pigmentation, carbon (p<0,039), manganese (p<0,007) and iron (p<0,015) were the statistically significant elements. The results of the comparison between the elements, regardless of the periodontal condi... (Complete abstract click electronic access below) / Mestre
136

Obtenção e caracterização de filmes finos de Bi3NbO7 pelo método dos precursores poliméricos /

Gonçalves, Lucas Fabrício. January 2014 (has links)
Orientador: Alexandre Zirpoli Simões / Banca: Mauricio Antonio Algatti / Banca: Cesar Renato Foschini / Resumo : O objetivo central deste trabalho foi obter filmes finos de Bi3NbO7 com boas propriedades dielétricas em alta frequência, utilizando solução orgânica de citrato, sal metálico e etileno glicol como precursor e o processo spin-coating para deposição. A resina é obtida pelo método dos precursores poliméricos devido às facilidades do processo como baixo custo dos precursores, controle da estequiometria e baixa temperatura de síntese. Após obter a solução precursora, poliéster, com viscosidade controlada os filmes foram tratados termicamente e caracterizados por Difração de raios-X, Microscopia Eletrônica de Varredura por Emissão de Campo, Microscópio de Força atômica, Microscópio Eletrônico de Transmissão, Análise Termogravimétrica e Analise Térmica Diferencial. A morfologia dos filmes foi correlacionada com a viscosidade, excesso de bismuto e temperatura de tratamento térmico utilizados na calcinação. Para estabelecer a melhor condição de tratamento térmico para obtenção da fase cristalina, preparou-se filmes em três ciclos distintos os quais foram caracterizados por Difração de raios-X. O melhor ciclo de tratamento foi o do filme tratado a 700°C, 800ºC e 850°C por 2 horas ou ciclo 3. Soluções com viscosidade em torno de 8,0 cPs foram utilizadas para depositar filmes em substratos de Si recoberto com Platina e LaNiO3 sob alumina pelo método spin-coating. Um estudo comparativo foi desenvolvido sobre tratamento térmico no ciclo 3. Observam-se filmes com baixa porosidade e homogêneos com morfologias distintas. Observou-se a formação da fase Bi3NbO7 com crescimento no plano ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The central objective of this study was to obtain thin films of Bi3NbO7 with good dielectric properties at high frequency using organic citrate solution , metal salt and ethylene glycol as the precursor and the spin -coating deposition . The resin is obtained by the polymeric precursor method because the facilities of the process as inexpensive precursors , control of stoichiometry and low -temperature synthesis . After obtaining the precursor , polyester solution with controlled viscosity films were heat treated and characterized by X- ray diffraction , Scanning Electron Microscopy Field Emission Microscope Atomic Force , Transmission Electron Microscope , Thermogravimetric Analysis and Differential Thermal Analysis . The morphology of the films was correlated with viscosity, excess bismuth and annealing temperature used in calcination. To establish the best condition for heat treatment to obtain the crystalline phase , prepared in three different cycles films which were characterized by X-ray diffraction . The best course of treatment was the film treated at 700 ı C , 800 º C and 850 ı C for 2 hours or 3 cycle . Solutions with viscosity around 8.0 cps were used to deposit films on Si substrates coated with platinum and LaNiO3 on alumina by spin-coating method. A comparative study was conducted on heat treated in cycle 3 . Films are observed with low porosity and homogeneous with distinct morphologies . We observed the formation of Bi3NbO7 growth phase with the plane ( 111 ) for films deposited on Si substrates coated ... (Complete abstract click eletronic access below) / Mestre
137

\"Sistemas adesivos autocondicionantes aplicados no esmalte: avaliação da resistência de união, morfologia de interface e padrão de condicionamento em função do tratamento e substrato\" / Self etching primers applied in the enamel: adhesive bond strength, interface morphology, etch pattern in relation the treatment and substrate

Lima, Janaina de Oliveira 08 February 2007 (has links)
Este estudo teve como objetivo verificar a possibilidade de utilizar o esmalte bovino, em teste resistência de união, substituindo o esmalte humano, bem como, analisar a resistência de união, morfologia de interface e padrão de condicionamento de sistemas adesivos autocondicionantes aplicados ao esmalte intacto e asperizado. Foram usados 40 dentes humanos e 40 dentes bovinos. Cada dente foi dividido em quatro regiões, de maneira a permitir a obtenção dos corpos-de-prova de todas as condições experimentais. Três sistemas adesivos autocondicionates; Clearfil Protect Bond (Kuraray Medical inc), Adper Prompt L-Pop (3M-ESPE), i Bond (Heraeus-Kulzer) foram testados, sendo utilizado um sistema de condicionamento total, Excite (Ivoclar-Vivadent), como controle positivo. A resina Tetric Ceram foi utilizada para a confecção dos corpos-de-prova, para resistência de união e amostras de microscopia eletrônica de varredura (MEV). As médias de resistência de união foram avaliadas por análise de variância e Tukey. Não houve diferença estatística, na resistência de união, entre os substratos, embora, as médias em esmalte humano tenham sido mais altas. A interação tripla; sistema Adesivo x Tratamento x Esmalte, também não foi significante, no entanto, manteve-se a tendência dos autocondicionantes de passo único apresentar as menores médias de resistência de união, principalmente no esmalte intacto. Houve diferença estatística para o fator sistema adesivo, sendo que o menor resultado foi obtido com o adesivo i Bond, na interação sistema adesivo x tratamento, a menor média também foi obtida pelo adesivo i Bond, quando aplicado ao esmalte intacto. O fator tratamento foi significante, sendo que, na variável de esmalte asperizado constatou-se a maior média de resistência de união, evidenciando que a asperização da superfície de esmalte, quando um sistema adesivo autocondicionante é aplicado no esmalte, constitui um passo operatório essencial. As imagens de MEV evidenciaram maior porosidade no dente bovino, independente do sistema adesivo utilizado e maior descalcificação do esmalte, tanto asperizado, quanto intacto, para os adesivos Excite e Adper Prompt L-Pop. Em relação à interface observou-se, que a camada de adesivo, no esmalte asperizado, tanto humano, quanto bovino, mostrou-se mais espessa, não importando o tipo de sistema adesivo; autocondicionante ou convencional. Os prismas de esmalte, no substrato bovino, mostraram um arranjo diferenciado, do observado no esmalte humano, porém esta diferença não promoveu alteração na resistência de união, visto que, não houve diferença estatística entre os substratos. Assim na impossibilidade de se obter esmalte humano, para testes de microtração, a utilização do esmalte bovino é viável. / The aim of this study was to verify the possibility in use the bovine enamel, as a substitute to human enamel, in the microtensile bond strength test, as well as analyze the bond strength, interface morphology and etch pattern of the self etching primers (SEP) applied in the cut and uncut, bovine and human, enamel. For this 40 human teeth and 40 bovine teeth were used, each tooth was divided in four halves to obtain all experimental conditions in the same tooth. Three SEP; Clearfil Protect Bond (CPB) (Kuraray Medical Inc), Adper Prompt L-Pop (LP) (3M-ESPE), i Bond (IB) (Heraeus-Kulzer) were tested, using a conventional adhesive system, Excite (EX) (Ivoclar Vivadent), as a positive control. A bulk of composite resin, Tetric Ceram (Ivoclar Vivadent), was build up for the specimens of microtensile test and SEM. In all above trials, some specimens were randomly selected and prepared for SEM. The data collected was submitted for statistical analyze ANOVA and Tukey test. It was possible to verify that there were no statistically differences between the substrate and triple interaction Adhesive Systems x Substrate x Treatment, but in the booth conditions, the SEP, i Bond, showed the lowest means, as same as, all means in bovine enamel were lowest than in human enamel. There were statistically differences between the systems adhesives and for treatment, cut and uncut. For adhesive systems the lowest value was observed for i Bond, in booth substrate and treatment. In the treatment conditions the greater means were observed in the cut enamel, showing that the cutting enamel is essential condition, to improve the bond strength of SEP, applied in the enamel. The SEM images, for etch pattern showed that in the bovine enamel the porosity was more thickness, for all adhesives and cut and uncut treatment. It was possible to verify, trough SEM of morphology interface, that the all adhesives in cut enamel, had adhesive layer more thickness, as and exception was the SEP, I Bond, that showed adhesive layers thinner. The bovine enamel showed a different arrangement for prisms that showed in the human enamel. We conclude that when the use of human enamel, in the microtensile test, is unviable, it is possible to use the bovine enamel as a substrate.
138

Descrição da morfologia externa dos jovens recém-eclodidos de Aegla paulensis Schmitt, 1942 e de Aegla perobae Hebling & Rodrigues, 1977 (Crustacea, Decapoda, Aeglidae) / Description of the external morphology of the newly-hatched juveniles of Aegla paulensis Schmitt, 1942 and Aegla perobae Hebling & Rodrigues, 1977 (Crustacea, Decapoda, Aeglidae)

Moraes, Juliana Cristina Bertacini de 24 May 2012 (has links)
O gênero Aegla Leach, 1820 representa o único táxon dentro de Decapoda Anomura com representantes adaptados exclusivamente a ambientes de água doce. As eglas são endêmicas da América do Sul e vivem em ambientes lóticos com alto nível de oxigenação. Estudos comparativos da morfologia de jovens recém-eclodidos podem contribuir para estabelecer relações de afinidade entre as cerca de 70 espécies já descritas que compõem a família Aeglidae. Porém, o número de trabalhos que descrevem a morfologia em detalhe nesta fase de vida é ainda escasso. O objetivo do presente estudo foi descrever detalhadamente a morfologia externa dos jovens recém-eclodidos das espécies Aegla paulensis e Aegla perobae, com base em Microscopia Óptica e em Microscopia Eletrônica de Varredura (MEV). Fêmeas ovígeras foram coletadas e transferidas para o laboratório a fim de se obter os jovens recém-eclodidos dos ovos. A descrição detalhada da morfologia do jovem recém-eclodido incluiu a carapaça, o abdome, os apêndices cefalotorácicos (antênula, antena, mandíbula, maxílula, maxila, maxilípedes, pereópodes) e a região do télson juntamente com os urópodes. As cerdas foram analisadas em detalhe quanto ao número, localização e tipo morfológico com o auxílio da MEV. Os resultados obtidos foram analisados e comparados com os das espécies que já tiveram seus jovens recém-eclodidos descritos e também com os adultos. As principais descobertas do estudo foram: as lineae aeglicae, os pleópodes rudimentares, a riqueza de tipos de cerdas e os poros sensoriais / Genus Aegla Leach, 1820 represents the one taxon within Decapoda Anomura with representatives exclusively adapted to freshwater environments. Aeglids are endemic to South America and they live in lotic environments with high levels of dissolved oxygen. Comparative studies of the newly-hatched juvenile morphology may contribute to establish affinity relations among the 70 species of the Aeglidae family already described. However, the number of studies which describe the morphology at this life phase in detail is still scarce. The objective of this study was to describe the external morphology of the newly-hatched juvenile of Aegla paulensis and Aegla perobae in detail, using Light Microscopy and Scanning Electron Microscopy (SEM). Newly-hatched juveniles were obtained from ovigerous females kept under laboratory conditions. Detailed description of the newly-hatched juveniles included the carapace, the abdomen, the cephalothoracic appendages (antennule, antenna, mandible, maxillule, maxilla, maxillipeds, pereiopods), and the telson-uropods region. SEM was used to analyze setae number, location and type. The results were analyzed and compared with those from newly-hatched juveniles already described and with adults. The main findings in this study were: lineae aeglicae, rudimentary pleopods, setae morphology diversity, and pores sensilla.
139

Caracterização de nanofibras através de técnicas de processamento de imagens. / Nanofibres characterization through image processing techniques.

Calíope, Priscila Braga 13 August 2009 (has links)
O electrospinning (deposição eletrostática) representa um método simples e conveniente para preparar bras poliméricas e bras cerâmicas com interiores sólidos ou ocos, excepcionalmente longos em comprimento, uniformes no diâmetro, variando no intervalo de dezenas de nanômetros a vários micrômetros, com diversicadas composições. Apesar da potencialidade e versatilidade da Microscopia Eletrônica de Varredura existe um grande problema de caracterizar nanobras, já que este processo não é feito automaticamente. Este trabalho apresenta uma nova metodologia para extração automática de medidas em imagens SEM, como uma alternativa eciente em relação aos softwares semi-automáticos propostos na literatura. A metodologia proposta envolve o processamento das imagens SEM usando Morfologia Matemática e os resultados obtidos são discutidos e comparados àqueles processados por Redes Neurais Celulares e pelo método de Otsu. Imagens coletadas do microscópio foram analisadas por técnicas de processamento de imagens para determinação do diâmetro das nanobras. Os resultados mostraram boa concordância entre as metodologias estudadas e o método padrão-ouro indicando que os mesmos podem substituí-lo para constituir uma alternativa automática na caracterização de nanobras. / The electrospinning technique represents a simple and convenient process to provide polymers and ceramics bers with both solid and hollow interiors that are exceptionally long in length, uniform in diameter, varying within the interval of few nanometers to several microns, and diversied in composition. Despite the versatility and potencially the scanning electron microscopy (SEM) there is a serious problem to characterize nanobers, as it is not made automatically. This work presents novel methodology software for automatic measurement in SEM images, as an eficient alternative in comparison with semi-automatic softwares proposed in literature. The proposed methodology involves the image processing SEM using Mathematical Morphology and the obtained results are argued and compared with those processing for Celullar Neural Network and Otsu method. The microscope images were assessed and analysed by imagery processing techniques to determinate diameters of nanobers. The results has shown good agreement between the investigated and gold standard methods suggesting that the same ones can substitute it to constitute an automatic alternative in the nanobers characterization.
140

Avaliação do desempenho e alteração de superfície das limas Wave One e One Shape no decorrer do número de usos / Performance and change surface of files Wave One and One Shape during the number of uses

Pires, Márcia Virginia Morante Porto 17 March 2015 (has links)
Os sistemas de lima única constituem a mais recente tecnologia no que se refere ao preparo dos canais radiculares, e vem sendo objeto de estudo sob diversos aspectos. Uma das preocupações referentes aos sistemas automatizados é a manutenção da qualidade e segurança nos preparos quando da reutilização do instrumento. Este estudo teve como objetivo avaliar as alterações de superfície de dois sistemas de lima única - Wave One e One Shape - e seu desempenho através do tempo de preparo no decorrer dos usos. Duzentos condutos de molares inferiores humanos extraídos foram instrumentados com 10 limas Wave One e 10 limas One Shape, acompanhados de irrigação com 10 ml de Hipoclorito de Sódio 2.5%. Cada instrumento foi utilizado por 10 vezes. Os tempos para o preparo completo do canal foram registrados por um cronômetro digital e anotados em tabelas. Para avaliação em microscopia eletrônica de varredura as limas novas foram observadas assim que removidas da embalagem. Após as utilizações, os instrumentos foram limpos, esterilizados em autoclave e observados após 2, 6, 8 e 10 usos. Três avaliadores calibrados observaram as fotomicrografias e registraram de acordo com os scores propostos a presença ou ausência de alterações superficiais. O teste Kappa de concordância entre os avaliadores apresentou maioria de resultados ótimo a moderado (?=5%). Os dados referentes à avaliação das imagens foram submetidos ao teste Wilcoxon-Mann-Whitney com nível de significância de 5% (?=5%). As alterações mais observadas foram aplainamento e microcavidade. O crack foi observado nos dois instrumentos sendo significante a partir do sexto uso para Wave One e do décimo para One Shape. Os dados relativos aos tempos de preparo foram submetidos à análise estatística pelos testes Wilcoxon-Mann-Whitney, ANOVA e Mc-Nemar com nível de significância de 5% (?=5%). Os tempos de preparo registrados para One Shape foram inferiores aos tempos para Wave One. O uso influenciou os tempos de preparo sendo observado um aumento significativo para os dois instrumentos. Um instrumento One Shape fraturou mas a ocorrência não foi estatisticamente significante. / Single-file systems are the most recent technology in regard to the preparation of root canals and have been studied in several ways. One of the concerns related to automated systems is maintaining quality and safety in preparation when the instrument is reused. This study\'s aim was to evaluate the changes on the surface of two single-file systems - Wave One and One Shape - and their performance through preparation time over the uses. Two hundred root canals of extracted human molars were instrumented with 10 Wave One files and 10 One Shape files, followed by irrigation with 10 ml of sodium hypochlorite 2.5%. Each instrument was used 10 times. The time required to complete each root canal was measured by a digital stopwatch and recorded in tables. New unused files were analysed using a scanning electron microscope. After used, the instruments were cleaned and sterilized, then observed after 2, 6, 8 and 10 uses. Three calibrated evaluators observed these SEM images and listed according to the suggested scores the presence or absence of changes on the surface. The Kappa test showed mostly results from moderate to great (? = 5%). The data relating to evaluation of images was submitted to the Wilcoxon-Mann-Whitney test with a significance level of 5% (? = 5%). The most frequent changes were blunt edges and microcavities. Cracking was observed in both instruments being significant in Wave One after the sixth use and in One Shape after the tenth use. Data on preparation times were statistically analysed by the Wilcoxon-Mann-Whitney, ANOVA and Mc-Nemar tests with a significance level of 5% (? = 5%). Regarding the working time taken to shape the canals, One Shape was significantly faster than Wave One. The preparation time was affected by the number of file use increasing significantly on both instruments. A One Shape instrument fractured but the finding was not statistically significant.

Page generated in 2.1193 seconds