• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 7
  • Tagged with
  • 7
  • 7
  • 7
  • 7
  • 7
  • 7
  • 6
  • 5
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Investigação do potencial cortical provocado visual para padrão reverso em pacientes diagnosticados com epilepsia parcial e generalizada

DUARTE, Regina Célia Beltrão 02 December 2011 (has links)
Submitted by Ana Rosa Silva (arosa@ufpa.br) on 2012-08-06T16:42:14Z No. of bitstreams: 2 Dissertacao_InvestigacaoPotencialCortical.pdf: 1300825 bytes, checksum: e29dc50db41425f1608dfcea32ebbc8b (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) / Approved for entry into archive by Ana Rosa Silva(arosa@ufpa.br) on 2012-08-06T16:42:48Z (GMT) No. of bitstreams: 2 Dissertacao_InvestigacaoPotencialCortical.pdf: 1300825 bytes, checksum: e29dc50db41425f1608dfcea32ebbc8b (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) / Made available in DSpace on 2012-08-06T16:42:48Z (GMT). No. of bitstreams: 2 Dissertacao_InvestigacaoPotencialCortical.pdf: 1300825 bytes, checksum: e29dc50db41425f1608dfcea32ebbc8b (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Previous issue date: 2011 / CNPq - Conselho Nacional de Desenvolvimento Científico e Tecnológico / FINEP - Financiadora de Estudos e Projetos / FAPESPA - Fundação Amazônia de Amparo a Estudos e Pesquisas / Este trabalho avaliou o potencial cortical provocado visual de crianças com história de epilepsia com o objetivo de identificar marcadores eletrofisiológicos que indicassem alterações corticais em epilepsia. Foram estudados 34 sujeitos com história de epilepsia (18 sujeitos com epilepsia parcial e 16 com epilepsia generalizada). O grupo controle foi composto por 19 sujeitos sem história de crises epilépticas com faixa etária semelhante aos pacientes. Os componentes do potencial cortical provocado visual transiente para apresentação por padrão reverso de tabuleiros de xadrez foram avaliados quanto à amplitude, tempo implícito e razões de amplitude entre os componentes. Foi observado que os pacientes com epilepsia generalizada apresentaram componente N75 com amplitude maior que os demais grupos, enquanto as razões de amplitude N75/P100 e P100/N135foram menores em pacientes com epilepsia parcial que em outros grupos. Houve fraca correlação linear entre os parâmetros do potencial cortical provocado visual e a idade de início das crises epilépticas ou tempo de utilização das medicações antiepilépticas. Conclui-se que o componente N75 e as razões de amplitude N75/P100 e P100/N135 podem ser bons indicadores eletrofisiológicos para alterações funcionais corticais em epilepsia. / The present work evaluated the visual evoked cortical potential of children with clinical history of epilepsy in order to identify electrophysiological marker indicating cortical changes in epilepsy. Thirty-four subjects with history of epilepsy along the lifetime (18 subjects diagnosed with partial epilepsy and 16 subjects diagnosed with generalized epilepsy). The control group was composed by 19 subjects age-matched with no history of epilepsy. Visual evoked cortical potential components for pattern-reversal presentation of chessboards were evaluated in amplitude, implicit time, and amplitude ratio of components. It was observed that generalized epilepsy patients had larger N75 than other two groups, whilst N75/P100 and P100/N135 ration were smaller in partial epilepsy patients than other groups. There was weak correlation between the electrophysiological parameters and the age of seizures onset or time of antiepileptic drugs intake. In conclusion, N75 amplitude and amplitude ratio can be good electrophysiological markers to cortical changes in epilepsy.
2

Eletrofisiologia da visão em modelo experimental de ratos com diabetes e hipotireoidismo

GUIMARÃES, Glenda Figueira 28 March 2014 (has links)
Submitted by Cleide Dantas (cleidedantas@ufpa.br) on 2014-08-13T12:27:57Z No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_EletrofisiologiaVisaoModelo.pdf: 2711799 bytes, checksum: 837e1db907b5ec94457aabc9d56b8935 (MD5) / Approved for entry into archive by Irvana Coutinho (irvana@ufpa.br) on 2014-08-22T14:03:26Z (GMT) No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_EletrofisiologiaVisaoModelo.pdf: 2711799 bytes, checksum: 837e1db907b5ec94457aabc9d56b8935 (MD5) / Made available in DSpace on 2014-08-22T14:03:26Z (GMT). No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_EletrofisiologiaVisaoModelo.pdf: 2711799 bytes, checksum: 837e1db907b5ec94457aabc9d56b8935 (MD5) Previous issue date: 2014 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / CNPq - Conselho Nacional de Desenvolvimento Científico e Tecnológico / O diabetes mellitus constitui um problema de saúde pública mundial devido ao seu potencial de morbidade e mortalidade. Esta patologia é caracterizada como uma desordem metabólica com hiperglicemia crônica, resultado de uma deficiência absoluta ou relativa na secreção e/ou ação da insulina. Associado a esse quadro, problemas com a tireoide são frequentemente encontrados em pacientes acometidos por diabetes, principalmente com o avançar da idade. Além disso, há um corpo de conhecimento que descreve que tanto o diabetes quanto o hipotiroidismo provocam isoladamente perdas visuais, no entanto, não há muitas publicações acerca da fisiologia envolvendo em conjunto ambas patologias com as complicações visuais. O presente trabalho objetivou investigar questões relevantes para uma compreensão mais detalhada do quadro de evolução do comprometimento retiniano em modelos animais acometidos concomitantemente por duas doenças: diabetes e hipotireoidismo. Para isso, foram utilizados 50 ratos Wistar machos (Rattus norvegicus), com dois meses de idade, pesando entre 80 a 120 gramas, divididos em quatro grupos: um grupo controle sem procedimentos; um grupo com hipotireoidismo optando por um modelo experimental de tireoidectomia bilateral; um grupo com diabetes, com aplicação de 200 mg/Kg a 2% de Aloxana; e dois grupos com as duas patologias, adotando ambos os procedimentos experimentais, alterando a sequência das patologias em questão. Nos grupos estudados foi utilizado para avaliar as alterações visuais, um método não invasivo amplamente utilizado no meio acadêmico que é o eletrorretinograma (ERG) em diferentes períodos de 30, 45 e 60 dias. Assim, encontramos uma diminuição da amplitude média da onda-a dos animais nos grupos com diabetes e com as duas patologias em todos os registros realizados, os que apresentaram maiores diferenças estatísticas foram em relação ao registro de estocópica máxima, como também diferença no potencial oscilatório de ambos os grupos com as duas patologias. Os resultados obtidos dão suporte à hipótese que as duas patologias concomitantes (diabetes e hipotireoidismo) diminuem significativamente as respostas do ERG. / Diabetes mellitus is a worldwide public health problem because of its potential morbidity and mortality. This pathology is characterized as a metabolic disorder with chronic hyperglycemia, results from an absolute or relative deficiency in the secretion and/or insulin action. Associated to this case, problems with the thyroid are often found in patients with diabetes, especially with advancing age. Furthermore, there is a body of knowledge describing that both diabetes and hypothyroidism cause visual loss, however, there are not many publications on the physiology involving both pathologies in conjunction with the visual complications. Therefore, this work aimed to investigate issues relevant to a more detailed understanding of the framework for the evolution of retinal impairment in animal models simultaneously affected by two diseases: diabetes and hypothyroidism. For this, 50 male Wistar rats (Rattus norvegicus) were used, two-months-old, weighing between 80 to 120 grams, divided into four groups: a control group without procedures; a group with hypothyroidism opting for a bilateral experimental model of thyroidectomy; a group with diabetes, with application of 200 mg/kg to 2% Aloxana; and two groups with both pathologies, adopting both experimental procedures by changing the sequence of the pathologies in question. In the studied groups, it was used the electroretinogram (ERG), a non-invasive method widely used in academia to evaluate the visual changes, in different periods of 30, 45 and 60 days. We found a decrease in the average amplitude of the wave-a of the animals in the groups with diabetes and with both pathologies in all the realized registrations, the ones that showed the highest statistical differences were in relation to the registration of maximum estocópica, as well as difference in oscillatory potential of both groups with both pathologies. These results support the hypothesis that both concomitant pathologies (diabetes and hypothyroidism) significantly diminish the ERG responses.
3

Valores normativos para o eletrorretinograma de campo total

JACOB, Mellina Monteiro 02 May 2012 (has links)
Submitted by Irvana Coutinho (irvana@ufpa.br) on 2012-06-08T16:17:12Z No. of bitstreams: 2 Dissertacao_MELLINAValoresNormativosEletro.pdf: 4797106 bytes, checksum: b86a051a620a524491d2f888ddfea0be (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) / Approved for entry into archive by Irvana Coutinho(irvana@ufpa.br) on 2012-06-08T16:17:53Z (GMT) No. of bitstreams: 2 Dissertacao_MELLINAValoresNormativosEletro.pdf: 4797106 bytes, checksum: b86a051a620a524491d2f888ddfea0be (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) / Made available in DSpace on 2012-06-08T16:17:53Z (GMT). No. of bitstreams: 2 Dissertacao_MELLINAValoresNormativosEletro.pdf: 4797106 bytes, checksum: b86a051a620a524491d2f888ddfea0be (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Previous issue date: 2012 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / FINEP - Financiadora de Estudos e Projetos / CNPq - Conselho Nacional de Desenvolvimento Científico e Tecnológico / Muitos laboratórios de eletrofisiologia visual não possuem seus próprios valores de normalidade para o eletrorretinograma de campo total. Isto prejudica a confiabilidade dos diagnósticos de diversas doenças que afetam as vias visuais. Desta forma, o objetivo deste trabalho foi estabelecer os valores normativos para o teste Eletrorretinograma de Campo Total para o Laboratório de Neurologia Tropical (LNT) da Universidade Federal do Pará (UFPA). Realizaram o eletrorretinograma 68 indivíduos saudáveis e sem queixas visuais divididos em três grupos de acordo com a faixa etária: 36 indivíduos pertenceram ao grupo 1 (entre 17 e 30 anos), 21 indivíduos ao grupo 2 (entre 31 e 45 anos) e 11 indivíduos ao grupo 3 (entre 46 e 60 anos). O protocolo de realização do teste seguiu as recomendações da ISCEV, com a utilização de seis tipos de estimulação. Quatro após adaptação escotópica e estimulação com intensidades de: 0,01 cd.s/m2 (resposta de bastonetes), 3,0 cd.s/m2 (resposta mista de cones e bastonetes e potenciais oscilatórios) e 10,0 cd.s/m2 (resposta mista adicional). Dois após adaptação fotópica em fundo de 30 cd/m2: 3,0 cd.s/m2 (resposta de cones e Flicker 30Hz). Para a análise dos resultados foram calculados os valores de amplitude e tempo implícito das ondas a e b obtidas em resposta a cada um dos seis tipos de estimulação utilizados. Estes valores foram descritos estatisticamente através da mediana, intervalos de confiança, 1º e 3º quartis, coeficiente de variação, média, desvio padrão e valores mínimos e máximos. Os grupos de maior faixa etária apresentaram menores valores de amplitude e atraso no tempo implícito. A utilização da transformada wavelet permitiu a melhor visualização das ondas sem alteração de amplitude e tempo implícito. Portanto, os valores normativos obtidos podem servir como parâmetros de normalidade confiáveis para auxiliar o diagnóstico de doenças retinianas. / Many visual electrophysiology laboratories don’t have their own normal values for full-field electroretinogram. This impairs the reliability of the diagnosis of various diseases affecting the visual pathways. Thus, the purpose of this study was to establish normative values for the full-field electroretinogram to the Laboratory of Tropical Neurology (LNT) of the Federal University of Pará (UFPA). Were tested using the electroretinogram 68 healthy subjects without visual complaints, divided into three groups according to age group: 36 subjects belonged to group 1 (17 to 30 years), 21 subjects in group 2 (31 to 45 years) and 11 individuals in group 3 (46 to 60 years). Six types of stimulus that follow ISCEV standards were presented. Four dark-adapted: 0.01 cd.s/m2 (rod response), 3.0 cd.s/m2 (mixed response and oscillatory potentials) and 10.0 cd.s/m2 (mixed additional response). Two light-adapted, 3.0 cd.s/m2 (Cone response and Flicker 30Hz), with 30 cd/m2 background adaptation. For analysis, a-wave and b-wave amplitude and implicit times values were calculated. These values were statistically described using the following values: median, confidence interval, 1st and 3rd quartiles, coefficient of variation, mean, standard deviation and minimum and maximum values. The older age groups had lower amplitude and delayed implicit time. Wavelet transform allowed better visualization of waves without change of amplitude and implicit time. Therefore, the normative values obtained can serve as reliable parameters of normality to assist the diagnosis of retinal diseases.
4

Investigação de danos visuais em pacientes diagnosticados com meningite criptocócica não associada à imunossupressão

LACERDA, Eliza Maria da Costa Brito 20 March 2014 (has links)
Submitted by Cleide Dantas (cleidedantas@ufpa.br) on 2014-06-26T12:01:48Z No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Tese_InvestigacaoDanosVisuais.pdf: 6789971 bytes, checksum: 01ae739027df6b9d9a97aa654021e47b (MD5) / Approved for entry into archive by Ana Rosa Silva (arosa@ufpa.br) on 2014-07-29T17:17:33Z (GMT) No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Tese_InvestigacaoDanosVisuais.pdf: 6789971 bytes, checksum: 01ae739027df6b9d9a97aa654021e47b (MD5) / Made available in DSpace on 2014-07-29T17:17:33Z (GMT). No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Tese_InvestigacaoDanosVisuais.pdf: 6789971 bytes, checksum: 01ae739027df6b9d9a97aa654021e47b (MD5) Previous issue date: 2014 / CNPq - Conselho Nacional de Desenvolvimento Científico e Tecnológico / FAPESPA - Fundação Amazônia de Amparo a Estudos e Pesquisas / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / FINEP - Financiadora de Estudos e Projetos / A meningite criptocócica é uma severa doença infecciosa causada pelo Cryptococcus spp. que apresenta alta letalidade e deixa nos sobreviventes uma série de sequelas sensoriais, entre as quais estão as alterações visuais. O objetivo deste estudo foi descrever as perdas visuais sofridas por pacientes, sem história de imunossupressão, diagnosticados com meningite criptocócica, de forma a indicar um possível mecanismo e fatores de risco para essas sequelas visuais. O trabalho foi composto de um estudo de série de casos de pacientes com meningite criptocócica sem história de imunossupressão (n = 7 pacientes, n = 14 olhos) e um estudo transversal analítico de todos os casos de meningite criptocócica sem história de imunossupressão notificados em 14 anos num hospital de referência do Pará (n = 113 casos). No estudo de série de casos, as funções visuais de uma amostra de pacientes foi cuidadosamente analisada por meio de avaliação oftalmológica, testes psicofísicos e eletrofisiológicos. No estudo transversal analítico, foi realizada análise de dados de prontuário com enfoque nas alterações visuais. Observou-se que os pacientes estudados na série de casos apresentaram grave diminuição da acuidade visual e mesmo em pacientes sem queixa visual houve alteração na percepção de cor, na percepção de contraste de luminância em diferentes frequências espaciais e no campo visual. Os testes indicam comprometimento da retina central como principal desencadeadora de uma cascata de alterações que impedem o normal processamento da imagem no córtex visual. Sugere-se que lesões do nervo óptico não foram as únicas responsáveis pelas alterações visuais observadas. Os principais fatores de risco para as alterações visuais observados pelo estudo transversal analítico foram o tempo de doença antes do início do tratamento e a resposta imunológica do paciente. / Cryptococcal meningitis is a severe infectious disease caused by Cryptococcus spp., which has high lethality and causes sensorial sequels. The most important sequels are visual impairments. The aim of this study was to describe the visual losses suffered by patients without immunosupression history, diagnosed with cryptococcal meningitis in order to indicate a possible mechanism and risk factors for the visual sequels. The work was composed by a case series study with cryptococcal meningitis without immunosupression history (n =7 patients, 14 = eyes) and an epidemiological study of all the cases of cryptococcal meningitis without immunosupression history notified during 14 years in the reference hospital of Para State (n = 113 cases). In the case series study, the visual functions of a sample of patients were studied by ophthalmological, psychophysical, and electrophysiological evaluation. The epidemiological study analyzed the medical records data focusing on visual impairment. It was observed that the studied patients in the case series study had visual acuity impairment. Even in patients without clinical complaints, color discrimination, luminance contrast sensitivity, and visual field were impaired. The results indicated central retina commitment as the principal responsible for a cascade of alterations that prevented the normal upstream image processing, at the visual cortex level. It is suggested that the observed visual dysfunction was due not only to optic nerve damage. The principal risk factors for the visual alterations observed in the epidemiological study were disease time before the beginning of the treatment and patient immunological response.
5

Propriedades espaciais das respostas isoladas de cones L e M ao eletrorretinograma: implicações sobre a atividade das vias visuais paralelas

JACOB, Mellina Monteiro 16 June 2015 (has links)
Submitted by Cássio da Cruz Nogueira (cassionogueirakk@gmail.com) on 2017-03-22T12:38:34Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_PropriedadesEspaciaisRespostas.pdf: 15352346 bytes, checksum: 42a960e0c4244827df1d88520a168e34 (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-03-24T16:29:43Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_PropriedadesEspaciaisRespostas.pdf: 15352346 bytes, checksum: 42a960e0c4244827df1d88520a168e34 (MD5) / Made available in DSpace on 2017-03-24T16:29:43Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_PropriedadesEspaciaisRespostas.pdf: 15352346 bytes, checksum: 42a960e0c4244827df1d88520a168e34 (MD5) Previous issue date: 2015-06-16 / CNPq - Conselho Nacional de Desenvolvimento Científico e Tecnológico / Foi estudada a organização espacial dos sinais de cones L e M ao eletrorretinograma (ERG), refletindo a atividade das vias pós-receptorais magno e parvocelular. Para tal, foram criados estímulos senoidais que isolavam as respostas de cones L e M e que eram emitidos por um estimulador que utilizava quatro primárias de LED, permitindo que fosse aplicado o paradigma da tripla substituição silenciosa. As frequências temporais utilizadas foram de 8 e 12 Hz, para refletir a atividade de oponência de cones, e 30, 36 e 48 Hz para refletir a atividade de luminância. As respostas de eletrorretinograma foram registradas com estímulos que alcançavam todo o campo visual (campo total) e por estímulos que variavam em configuração espacial, entre estímulos circulares e anelares com diâmetros diferentes. Os resultados obtidos confirmam a presença de dois mecanismos de resposta diferentes a estímulos com frequências temporais intermediárias e altas. As respostas de ERG medidas em frequências temporais altas dependeram fortemente da configuração espacial de estimulação. Nas condições registradas com campo total (Full-field electroretinogram, FF), as respostas de cones L foram substancialmente maiores do que as respostas de cones M na mesma condição, e do que as respostas de cones L a estímulos menores. Já as respostas de cones M aos estímulos com campo total e com diâmetro de 70º, apresentaram valores de amplitude similares. As respostas de cones L e M medidos com frequências temporais de 8 e 12 Hz, apresentaram amplitudes similares, e estavam aproximadamente em contra-fase. As amplitudes foram constantes para a maioria das configurações de estimulação. Os resultados indicaram que, quando as respostas de ERG refletem a atividade de luminância, elas estão correlacionadas positivamente com o tamanho do estímulo. Além de 35º de excentricidade retiniana, a retina contém principalmente cones L. Estímulos pequenos são suficientes para obter respostas máximas de ERG em frequências temporais intermediárias, onde o ERG é sensível também ao processamento de oponência de cones. / We studied the spatial arrangement of L- and M-cone driven electroretinograms (ERGs) reflecting the activity of magno- and parvocellular pathways. L- and M-cone isolating sine wave stimuli were created with a four primary LED stimulator using triple silent substitution paradigms. Temporal frequencies were 8 and 12 Hz, to reflect cone opponent activity, and 30, 36 and 48 Hz to reflect luminance activity. The responses were measured for full-field stimuli and for different circular and annular stimuli. The ERG data confirm the presence of two different mechanisms at intermediate and high temporal frequencies. The responses measured at high temporal frequencies strongly depended upon spatial stimulus configuration. In the full-field conditions, the L-cone driven responses were substantially larger than the full-field M-cone driven responses and also than the L-cone driven responses with smaller stimuli. The M-cone driven responses at full-field and with 70° diameter stimuli displayed similar amplitudes. The L- and M-cone driven responses measured at 8 and 12 Hz were of similar amplitude and approximately in counter-phase. The amplitudes were constant for most stimulus configurations. The results indicate that, when the ERG reflects luminance activity, it is positively correlated with stimulus size. Beyond 35° retinal eccentricity, the retina mainly contains L-cones. Small stimuli are sufficient to obtain maximal ERGs at low temporal frequencies where the ERGs are also sensitive to cone-opponent processing.
6

Potencial cortical provocado visual gerado por estímulos pseudoisocromáticos

SALOMÃO, Railson Cruz 11 October 2016 (has links)
Submitted by Cássio da Cruz Nogueira (cassionogueirakk@gmail.com) on 2017-03-27T14:33:09Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_PotencialCorticalProvocado.pdf: 967305 bytes, checksum: c9d38853b7fb33f61c42d51cac59ada3 (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-04-11T13:06:39Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_PotencialCorticalProvocado.pdf: 967305 bytes, checksum: c9d38853b7fb33f61c42d51cac59ada3 (MD5) / Made available in DSpace on 2017-04-11T13:06:39Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_PotencialCorticalProvocado.pdf: 967305 bytes, checksum: c9d38853b7fb33f61c42d51cac59ada3 (MD5) Previous issue date: 2016-10-11 / FAPESPA - Fundação Amazônia de Amparo a Estudos e Pesquisas / O potencial cortical provocado visual (VECP) são úteis na investigação de mecanismos da visão de cores e disfunções de visão de cores. Redes senoidais cromáticas são geralmente usadas para gerar o VECP, mas exigem medidas psicofísicas antes para realizar a equalização de brilho das redes. Uma alternativa pode ser a substituição delas por estímulos pseudoisocromáticas que fazem uso de ruído de luminância e forçar a percepção do alvo ser dependente de contraste cromático. Neste trabalho, comparamos VECPs gerados por redes senoidais cromáticas isoluminantes e redes pseudoisocromáticas. Esta pesquisa foi aprovada pelo Comitê de Ética em Pesquisa, Núcleo de Medicina Tropical da Universidade Federal do Pará, Protocolo # 570434. Sete tricomatas normais foram testados com redes sinusoidais cromáticas e redes ilusórios proporcionado pelo estimulo pseudoisocromático de 0,33, 0,66, 1, 1,33, 1,66, e 2 cpg, apresentado no padrão reverso (1 Hz) e padrão onset (300 ms) - offset (700 ms) modos. Os sinais foram registrados usando eletrodos de superfície, x30,000 amplificado, digitalizado a 1 kHz, e filtrada entre 0,1-100 Hz. VECP de reversão provocado por redes pseudoisocromáticas teve amplitude e latência semelhante em comparação com aqueles provocada por redes senoidais. VECPs onset-offset desencadeados por redes senoidais teve maior amplitude e menor latência do que os obtidos com o estímulo pseudoisocromático. Diferentes mecanismos visuais são responsáveis pelas respostas corticais provocado por estímulos ilusórios quando apresentado em diferentes modos de estimulação. / Visual evoked cortical potentials (VECP) are useful the investigation of color vision mechanisms and color vision dysfunctions. Chromatic sinusoidal gratings are generally used to elicit VECP, but they require long psychophysical measurements to match the perceptual brightness between their stripes. An alternative is to replace them by pseudoisochromatic stimuli which make use of luminance noise to mask brightness clues and force the target perception to be dependent of chromatic contrast. In this work, we compared VECPs generated by sinusoidal and pseudoisochromatic gratings. This research was approved by the Comitê de Ética em Pesquisa, Núcleo de Medicina Tropical, Universidade Federal do Pará, Protocol #570434. Seven normal trichromats were tested with chromatic sinusoidal gratings and illusory gratings provided by the pseudoisochromatic design of 0.33, 0.66, 1, 1.33, 1.66, and 2 cpd, presented in pattern reversal (1 Hz) and pattern onset (300 ms) – offset (700 ms) modes. The signals were recorded using surface electrodes, amplified x30,000, digitized at 1 kHz, and filtered between 0.1-100 Hz. Pattern reversal VECPs elicited by pseudoisochromatic gratings had similar amplitude and latency compared to those elicited by sinusoidal gratings. Onsetoffset VECPs elicited by sinusoidal gratings had larger amplitude and shorter latency than those obtained with pseudoisochromatic stimuli. Different visual mechanisms are responsible for the cortical responses evoked by illusory stimuli when presented in different stimulation modes.
7

Ganho de contraste do potencial cortical provocado visual multifocal: efeitos da excentricidade e do modo de estimulação

SILVA, Veronica Gabriela Ribeiro da 29 November 2016 (has links)
Submitted by Cássio da Cruz Nogueira (cassionogueirakk@gmail.com) on 2017-03-27T14:41:27Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_GanhoContrastePotencial.pdf: 2379799 bytes, checksum: b7c8f6c20a4ffc70c03cd986fadbb07f (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-04-11T15:56:44Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_GanhoContrastePotencial.pdf: 2379799 bytes, checksum: b7c8f6c20a4ffc70c03cd986fadbb07f (MD5) / Made available in DSpace on 2017-04-11T15:56:44Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_GanhoContrastePotencial.pdf: 2379799 bytes, checksum: b7c8f6c20a4ffc70c03cd986fadbb07f (MD5) Previous issue date: 2016-11-29 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Neste estudo foram avaliadas as possíveis contribuições das vias paralelas visuais M e P para o potencial cortical provocado visual em diferentes excentricidades visuais usando o ganho de contraste como indicador fisiológico no primeiro (K2.1) e segundo (K2.2) slices do kernel de segunda ordem dos potenciais corticais provocados multifocais (mfVEPs). O trabalho foi aprovado pelo comitê de ética em pesquisa (023/2011 – CEP/NMT) do Núcleo de Medicina Tropical, Universidade Federal do Pará. Nove sujeitos (22,5 ± 3,7 anos de idade) com visão normal foram testados. O estímulo foi gerado através do programa VERIS (EDI, San Mateo, CA) e consistiu em um tabuleiro de dardos ocupando 44° do ângulo visual, com 60 setores escalonados considerando a magnificação cortical, onde cada setor continha 16 quadrados (8 pretos e 8 brancos) com contraste espacial de luminância e luminância média de 40 cd/m², mostrados através de um monitor CRT, situado a uma distância de 32 cm do indivíduo testado. Cada setor foi temporalmente modulado por uma sequência-m pseudo-aleatória no modo de apresentação de padrão reverso e padrão de pulso em cinco contrastes de Michelson entre 6,25-100%. Foram extraídos os dados de K2.1 e K2.2 dos mfVEPs. Calcularam-se os valores médios de amplitude de registros correspondentes a 6 diferentes anéis de mesma excentricidade no campo visual (A1 e A6 sendo os anéis mais interno e externo, respectivamente) em função do contraste do estímulo. Os dados de amplitude em função do contraste do estímulo foram modelados por funções de Michaelis-Menten. A constante de semissaturação (C50) do modelo foi o indicador inversamente proporcional do ganho de contraste da função. Em K2.1, respostas para o padrão reverso apresentaram um alto valor do C50 (média, desvio padrão: 35,5% ± 9,3), indicando baixo ganho de contraste na função. Para os anéis mais externos (A2 – A6), foram estimados C50 inferiores aos estimados em A1 (média, desvio padrão: A2: 26,5% ± 6,5; A3: 22,4% ± 8,8; A4: 18,4% ± 4,4; A5: 20,6% ± 9,3; A6: 26,7% ± 12), representando funções de alto ganho de contraste. Em K2.2, no anel central (A1) e no mais periférico (A6), as funções de resposta ao contraste geradas pelo padrão reverso apresentaram um alto valor do C50 (média, desvio padrão: 38,4% ± 4,2; 37,5% ± 10,2), indicando baixo ganho de contraste na função. De A2 a A5, originou funções com valores de C50 inferiores aos estimados em A1 (média, desvio padrão: A2: 27,4% ± 7,4; A3: 20,2% ± 4,9; A4: 22,4% ± 4,2; A5: 18,7% ± 3,2; A6: 23,1% ± 8,9), representando funções de alto ganho de contraste. Para o padrão de pulso, no K2.1 e K2.2, no anel central (A1) e no K2.2 no anel mais externo (A6), as funções de resposta ao contraste geradas não apresentaram valores significativos e confiáveis para a análise. Em K2.1 os anéis intermediários (A2 – A5) originaram funções com alto C50 (média, desvio padrão: A2: 44,7% ± 10,5; A3: 38,3% ± 12,1; A4: 45,8% ± 12,1; A5: 49,4% ± 16,1; A6: 47,8% ± 14,7), representando funções de baixo ganho de contraste. Em K2.2, nos anéis intermediários (A2 – A5, exceto em A4) a estimulação originou valores de C50 maiores do que em K2.1 (média, desvio padrão: A2: 50,2% ± 10,3; A3: 48,2% ± 11,1; A4: 28,5% ± 4,2; A5: 54,3% ± 16,2), representando funções de baixo ganho de contraste. Para o padrão reverso, os resultados sugerem a predominância da via M nos anéis excêntricos intermediários e da via P no anel mais central (A1) e no mais periférico (A6). Para o padrão de pulso, sugere predominância da via P em todas as excentricidades. / This study evaluated effects of eccentricity and mode presentation on the multifocal visual evoked potential (mfVEPS) recordings extracted by second-order kernels and its possible contributions from parallel visual pathways. Nine subjects (22.5 ± 3.7 years-old) were studied. All the subjects had 20/20 or corrected visual acuity and no previous history of neuro-ophtahlmic diseases or degenerative diseases. The subjects were tested with non dilated pupil in a monocular way. All the experimental procedures agreed to the tenets of Helsinki and were approved by Committee for Ethic in Research of Nucleus of Tropical Medicine (023/2011 protocol, Federal University of Pará, Belém, PA, Brazil). A CRT monitor displayed a 22º radius, 60 sectors dartboard, each sector with 16 checks (8 white and 8 black), pattern mean luminance of 40 cd/m2. The pattern selection to be shown in each sector was temporally modulated according to a binary pseudorandom m-sequence. Two stimulation protocols were used and we called them as pattern reversal and pattern pulse. Stimulus was presented at five Michelson contrast levels (100%, 50%, 25%, 12.5%, and 6.25%) in two trials with increasing and decreasing contrast order. The subject was instructed to keep the eye in a red cross (1º) placed at the center of the screen. Veris 6.01 was used to configure the stimuli. mfVEPs were recorded with gold cup electrodes: the reference electrode was placed at the inion; the recording electrodes were placed at, 4 cm above the inion (channel 1), 1 cm above and 4 cm to the right of the inion (channel 2), 1 cm above and 4 cm to the left of the inion (channel 3). Ground surface electrode was placed at the forehead. Skin impedance was kept below 5 KOhm. Recordings were amplified 100.000x, band-pass filtered between 3 and 100 Hz. The Veris 6.1 performed an offline low-pass filtering at 35 Hz. Veris 6.1 was used to extract first (K2.1) and second (K2.2) slices from second-order kernels data from original channels. Using MATLAB routines three additional channels were computed from the subtraction of the three original channels. For each subject, a signal-to-noise ratio (SNR) evaluation was performed over the averaged data of two trials in each one of the 6 channels. We measured the RMS amplitude of signal and noise interval of each recording. Finally, we analyzed the waveforms with best SNR for each sector. Mean RMS amplitude for each of six eccentric rings (R1 and R6 are the inner and outer rings, respectively) and for all rings together as a function of stimulus contrast was modeled using Michaelis-Menten functions. Semi-saturation constant (C50) of the contrast-response function was used as indicator of response contrast gain. For pattern reversal protocol contrast-response functions from K2.1/K2.2 had the following C50 values: R1: 35,5% ± 9,3; R2: 26,5% ± 6,5; R3: 22,4% ± 8,8; R4: 18,4% ± 4,4; R5: 20,6% ± 9,3; R6: 26,7% ± 12 / R1: 38,4% ± 4,2; R2: 27,4% ± 7,4; R3: 20,2% ± 4,9; R4: 22,4% ± 4,2; R5: 18,7% ± 3,2; R6: 23,1% ± 8,9. For pattern pulse protocol contrast-response functions from K2.1/K2.2 had the following C50 values: R1: 0; R2: 44,7% ± 10,5; R3: 38,3% ± 12,1; R4: 45,8% ± 12,1; R5: 49,4% ± 16,1; R6: 47,8% ± 14,7 / R1: 0; R2: 50,2% ± 10,3; R3: 48,2% ± 11,1; R4: 28,5% ± 4,2; R5: 54,3% ± 16,2; R6: 0. Two contrast sensitivity mechanisms contribute to mfVEPs elicited by stimuli located in the central visual field, one mechanism with higher contrast gain (pattern reversal mfVEP) and other mechanism with low contrast gain (pattern pulse). For stimulus at the periphery visual field, mechanism with high contrast gain contributed to the generation of mfVEPs elicited by all stimulation modes.

Page generated in 0.0648 seconds