Spelling suggestions: "subject:"eletroforese capilar"" "subject:"eletroforese papilar""
141 |
Propostas metodologicas para componentes em matrizes alimenticias, alimentos enriquecidos e contaminantes utilizando eletroforese capilar acoplada a espectrometria de massas e detecção UV/VIS / Methodological proposals for food matrix components, enriched foods and contaminants using capillary electrophoresis coupled to mass spectrometry and UV/Vis detectionTatiana Shizue Fukuji 20 December 2011 (has links)
O trabalho envolve o desenvolvimento de métodos para análise de alimentos visando a determinação de ácidos fenólicos em frutas, ácido fólico em farinhas enriquecidas e corantes Sudan em produtos de pimenta utilizando eletroforese capilar nos modos de detecção UV e MS. A separação de dez ácidos fenólicos (ácidos clorogênico, siríngico, p-cumárico, benzóico, p-hidroxibenzóico, ferúlico, vanílico, cafeico, gálico e protocatecuico) foi obtida por eletroforese capilar de zona (CZE). Um eletrólito composto de 50 mmol L-1 de tetraborato e 7,5% metanol (v/v) permitiu a separação em linha de base dos dez ácidos fenólicos em menos de 15 minutos. A fim de promover o \"clean-up\", pré-concentração e liberação dos ácidos fenólicos esterificados, um procedimento de extração líquido-líquido seguido pela hidrólise alcalina foi realizado. O método foi validado obtendo-se limites de detecção de 1,63-3,80 µg mL-1 e limites de quantificação de 4,95-11,39 µg mL-1. O método otimizado foi aplicado para análise de frutas como a abiu-roxo (Chrysophyllum caimito), amora silvestre (Morus nigra L.) e tomate de árvore (Cyphomandra betacea), identificando os ácidos fenólicos na fração livre e hidrolisada. Este trabalho também otimizou o processo de extração e caracterizou a composição de ácidos fenólicos na forma livre e hidrolisada presentes no açaí Juçara (Euterpe precatória Mart.), açaí do Pará (Euterpe oleracea) e em produtos comercias de açaí como polpa congelada e \"açaí na tigela\". Para a determinação do ácido fólico, estudos de pré-concentração online foram realizados. A focalização do ácido fólico foi obtida por CZE e MEKC, devido a fenômenos de isotacoforese transiente. Um método de extração simples baseado na dissolução da farinha em solução de Na2HPO4 seguida de ultrassom e adição de HCl concentrado foi adotado. Entretanto, a detecção do ácido fólico no extrato foi obtida por MEKC com injeção de grande volume de amostra em condições eletroforéticas de 40 mmol L-1 TBS e 30 mmol L-1 SDS, 15 kV a 310 nm. Os limites de detecção e de quantificação atingidos foram de 0,047 e 0,14 µg mL-1, sendo adequados para quantificação do ácido fólico em farinhas de trigo. Um método para determinação de corantes Sudan (I, II, III e IV) em alimentos foi desenvolvido por cromatografia eletrocinética micelar (MEKC) com preenchimento parcial do capilar. A separação dos quatro corantes foi obtida utilizando-se um preenchimento de 25% do capilar (volume total) com eletrólito composto por 40 mmol L-1 NH4HCO3, 25 mmol L-1 SDS e 32,5% ACN (v/v). O restante do capilar foi preenchido com um tampão composto de 40 mmol L-1 NH4HCO3 e 32,5% (v/v) de ACN. Após otimização do método por CE-UV o método foi aplicado para o acoplamento ao CE-MS. Para detecção dos compostos no MS os parâmetros de ionização foram otimizados. A separação em linha de base dos quatro compostos foi obtida em menos de 10 min com limites de detecção de 0,57 a 0,75 µg mL-1 para detecção no UV-Vis e 0,05 a 0,2 µg mL-1 para detecção no MS. O método foi eficaz para a determinação destes corantes adicionados a amostras de molho de tomate e pimenta e chilli em pó / The present work involves the development of methods for food analysis in order to determinate phenolic acids in fruits, folic acid in enriched flour and Sudan dye in chilli products by capillary electrophoresis with UV/Vis and MS detection. The separation of ten phenolic acids (benzoic, caffeic, chlorogenic, p-coumaric, ferulic, gallic, p-hydroxybenzoic, protocatechuic, syringic, and vanillic acid) was obtained by capillary zone electrophoresis (CZE). An electrolyte composed by 50 mmol L-1 of tetraborate and 7,5% methanol (v/v) allowed the baseline resolution of all phenolic acids under investigation in less than 15 min. In order to promote sample clean up, to preconcentrate the phenolic fraction and to release esterified phenolic acids from the fruit matrix, elaborate liquid-liquid extraction procedures followed by alkaline hydrolysis were performed. The proposed method was validated with limits of detection of 1.63-3.80 µg mL-1 and limits of quantification of 4.95-11.39 µg mL-1. The optimized method was applied to evaluation of phenolic contents of abiu-roxo (Chrysophyllum caimito), wild mulberry (Morus nigra L.) and tree tomato (Cyphomandra betacea). This work also optimized the extraction process and characterized the free and hydrolysed forms of phenolic acids in Juçara açaí (Euterpe precatória Mart.), Pará´s açaí (Euterpe oleracea) and commercial products such as frozen pulp and açaí desserts. For the determination of folic acid, on-line preconcentration studies were performed. The focalization of folic acid was obtained by CZE and MEKC by transient isotacophoresis. A simple method of extraction based on dissolution of flour in a Na2HPO4 solution followed by ultrasonication and the addition of concentrated HCl was adopted. However, the detection of folic acid in flour extract was obtained by MEKC with the large volume sample injection with eletrophoretic conditions of 40 mmol L-1 TBS and 30 mmol L-1 SDS, 15 kV and 310 nm. The limits of detection and quantification reached were 0.047 and 0.14 µg mL-1, which are suitable limits to quantify folic acid in enriched wheat flours. A method of Sudan dyes (I, II, III and IV) was developed by micellar electrokinetic chromatography (MEKC) with partial filling technique. Filling 25 % of the capillary with a MEKC solution containing 40 mmol L-1 NH4HCO3, 25 mmol L-1 SDS and 32.5 % ACN (v/v), a baseline separation of the four azo-dyes was obtained. The rest of capillary was filled with 40 mmol L-1 NH4HCO3 and 32.5 % ACN (v/v). After the optimization by CE-UV the method was applied to CE-MS coupling. To detect the compounds in MS the ionization parameters were optimized. The baseline separation of four compounds was obtained in less than 10 min with limit of detection within 0.57 to 0.75 µg mL-1 to UV-Vis detection and 0.05 to 0.2 µg mL-1 to MS detection. The method was efficient in the determination of these dyes spiked in tomato chilli sauces and chilli powder.
|
142 |
Utilização da eletroforese capilar com eletrólitos não-tamponado para o estudo do comportamento dos íons hidrônio e hidroxila e seu desdobramento analítico / The use of capillary electrophoresis with unbuffered running electrolyte to study hydronium and hydroxyl behavior and its analytical outcome.Renata Mayumi Saito 26 June 2007 (has links)
Neste trabalho, foram efetuados estudos sobre o comportamento eletroforético dos íons hidrônio (H3O+) e hidroxila (OH-) utilizando eletroforese capilar em zona em meio não-tamponado e detecção condutométrica sem contato. Alterações na composição do eletrólito de corrida devido à eletrólise foram evitadas empregando um sistema de eletrólise separada. A determinação de ácidos com pKas menores ou iguais ao pH do eletrólito de corrida foi possível. A possibilidade da análise em bases fortes também foi demonstrada. Eletrólitos de corrida com pH entre 4,5 e 7,0 (para o H3O+) e entre 7,0 e 9,0 (para o OH-) mostraram-se favoráveis para a análise. Ambas as espécies apresentaram interação com os grupos silanóis do capilar. Dificuldades na análise do íon OH- decorreram também de: reação da sílica com o analito e com o eletrólito de corrida e absorção de CO2 atmosférico. A mobilidade do íon H3O+ medida foi 8% abaixo da obtida por outras técnicas. A curva para determinação de OH- em base forte, com solução de trifluoracetato de lítio 10 mmol L-1 (pH 8,5) como eletrólito de corrida, mostrou boa linearidade na faixa de 0,5 a 7,0 mmol L-1. As curvas de quantificação de H3O+ titulável em amostras de ácidos fortes, fracos e suas misturas, com solução de LiCl (pH 5,5) como eletrólito de corrida, apresentaram ampla faixa de resposta linear, com boa linearidade, ao redor de 0,05 a 10 mmol L-1. / In this work, studies about the electrophoretic behavior of hydronium (H3O+) and hydroxyl (OH-) ions using capillary zone electrophoresis in unbuffered medium and contactless conductity detection were developed. Variations in running electrolyte composition due to electrolysis were avoided using an electrolysis separated system. The analysis of acids with the same or lower pKa than the running electrolyte pH was possible. The possibility of strong bases analysis was demonstrated as well. Good results were achieved using running electrolytes with pH between 4.5 and 7.0, for H3O+ analysis, and between 7.0 and 9.0, for OH- analysis. Both species interacted with the silanol groups of silica capillary. Other problems in the determination of OH- were: reaction of silica with the analyte as well as with the running electrolyte and absorption of atmospheric CO2. The H3O+ mobility calculated was 8% lower than values obtained in the literature. Analytical curve of OH- ion in strong base, using 10 mmol L-1 litium trifluoracetate (pH 8.5) as running electrolyte, resulted in good linearity in a range of 0.5 to 7.0 mmol L-1. Analytical curves of titrable hydronium ion in samples of strong and weak acids, as well in their mixture, using 10 mmol L-1 LiCl (pH 5.5) as running electrolyte, resulted in wide linear range (0.05 mmol L-1 to 10 mmol L-1).
|
143 |
Aperfeiçoamento de métodos para a determinação de componentes ácidos e básicos em amostras de água de chuva / Enhancement of methods for the determination of acid and alkaline compounds in rainwater samplesLucia Helena Gomes Coelho 14 April 2005 (has links)
O estudo da variação da composição atmosférica contribui para a compreensão dos efeitos das emissões antrópicas sobre a troposfera. A análise química da água de chuva assume importância neste contexto, uma vez que a precipitação úmida constitui um excelente meio de remoção de muitos poluentes da atmosfera. O aumento de acidez das chuvas, em várias partes do planeta, tem sido associado, predominantemente, à presença de ácidos fortes como o sulfúrico e nítrico, e ácidos orgânicos como acético e fórmico, originados pela oxidação de compostos de enxofre, nitrogênio e carbono, respectivamente. Dando continuidade a pesquisas anteriores sobre deposição úmida realizadas no IQ-USP, no presente trabalho buscou-se extrair mais informações de titulações potenciométricas e condutométricas de água de chuva, mediante aperfeiçoamento dos métodos de cálculo, com recursos quimiométricos modernos, de modo a complementar as medidas de pH e condutividade convencionais. As concentrações de espécies ácidas ou básicas nas amostras de água de chuva são da ordem de 10-5 mol L-1, muito abaixo das concentrações empregadas na prática cotidiana das titulações potenciométricas (tipicamente, no intervalo de 10-1 a 10-3 mol L-1). Dessa forma, propôs-se o uso de um método de regressão não linear (RNL) multiparamétrica, baseado no método de Levenberg-Marquardt, para a análise de dados potenciométricos (TP-RNL) após procedimento de transposição de coordenadas das curvas de titulação. Ao lado das determinações das concentrações dos analitos, pôde-se estimar ou refinar as constantes de protonação das bases de Brönsted presentes. Para tanto, procedeu-se ao ajuste por RNL das concentrações e/ou das constantes de protonação das bases presentes, de modo a minimizar o quadrado dos desvios entre os valores experimentais e os calculados em função do titulante adicionado, recorrendo a uma equação geral baseada no número médio de protonação de cada uma das bases. Ficou demonstrada a possibilidade de se determinar a soma de ácidos fortes completamente dissociados, soma de ácidos fracos com pK próximo a 4 (principalmente ácidos acético e fórmico), HCO3-/H2CO3 e a soma de bases fracas com pK ao redor de 9 (essencialmente NH3/NH4+). Durante as titulações, a facilidade em se coletar medidas de condutância simultaneamente às de pH levou a elaboração de um método sofisticado de análise de curvas de titulação condutométrica. Para tanto, desenvolveu-se uma equação de RNL baseada na contribuição das espécies em cada valor de pH e na condutância iônica medida (TC-RNL). A equação de TC-RNL é alimentada por dados de pH em função do titulante adicionado, oriundos de titulações potenciométricas. Dessa forma, foi possível caracterizar diretamente amônio e bicarbonato, além do conteúdo iônico total que não participa dos equilíbrios ácidos/base existentes no sistema. Adicionalmente, foi possível separar a contribuição do ácido acético da do fórmico, tarefa impossível por TP-RNL, ao menos nas baixas concentrações encontradas na chuva. Nas mesmas amostras de chuva tituladas foi procedida a análise por eletroforese capilar de zona com detecção condutométrica sem contato (CZE-CCD), conforme procedimento descrito na literatura, estimando-se os cátions e ânions majoritários. Num aperfeiçoamento do método para ânions, viabilizou-se a determinação simultânea HCO3-. Para validar os resultados obtidos por CZE-CCD, recorreu-se à cromatografia de íons. As concentrações de vários analitos, dependendo das amostras de chuva, avizinham-se do limite de quantificação das técnicas TP-RNL, TC-RNL e CZE-CCD. Mesmo assim, para as amostras de chuva analisadas, em geral, houve concordância satisfatória entre os valores estimados pelas três técnicas para espécies agrupadas da seguinte forma: ácidos fortes, ácidos fracos, amônio e bicarbonato. / Ivestigation of the variability of atmospheric chemical composition is an important tool for the evaluation and comprehension of anthropic emissions effects.Rainwater analysis has great importance in this context because wet deposition represents an efficient removal route of many atmospheric pollutants. The acidification of rainwater over wide regions of the planet is associated with the increased presence of strong acids, like sulfuric and nitric ones, and organic acids, such as acetic and formic, mainly originated from oxidative reactions od sulfur, nitrogen and carbon compounds in the atmosphere. In the context of a broad research line at IQ-USP devoted to the study of wet deposition and associated atmospheric chemistry, this dissertation advances the subject of using moderm chemometric methods to extract reliable analytical information from potentiometric and conductometric titrations of rainwater. The concentrations of acidic and alkaline species in rainwater are typically below 5 x 10-5 mol L-1, out of the reach of conventional potentiometric titrations (widely applied in the range of 10-1 and 10-3 mol L-1). Thus, multiparametric non-linear regression based on Levenberg-Marquardt method combined with coordinates transposition to reduce iterative calculation is proposed for the analysis of potentiometric data (PT-NLR). General equations based on the average protonation number of each base are used to describe the system. Bases concentrations and/or protonation constants are adjusted by NLR in order to minimize the sum-of-squares of the residuals between experimental and calculated values of the titration curves. The data analysis was tuned to provide four parameters as output: the sum of strong acids, the sum of weak acids with pK around 4.2 (mainly acetic and formic acids), the sum of HCO3-/H2co3 and the sum of weak bases with pK near 9 (essentially NH3/NH4+). To extract more analytical information from the acid/base titrations, conductance meassurements were made simultaneously with the pH readings, and a sophisticated data analysis method was envisioned. The pH data and available protonation constants for bases included in the model are used to compute the distribution of the species. The available conductivity of each species of the model is introduced in a general equation where the only unknowns are the total concentrations of the bases and of electrolyte not involved in acid/base equilibria. All these concentrations are adjusted by NLR on the conductance data, resulting in the first successful conductometric titration method with non-linear regression analysis, CT-NLR. The great advantage over PT-NLR was the capability to distinguish the contributions of acetic and formic acids in rainwater (an impossible task in PT-NLR method), but total strong acids, ammonium and bicarbonate are determined as well, beside the total ionic content of species not involved acid-base equilibria. Rainwater samples were also analysed by capillary zone electriphoresis equipment with contactless conductometric detection (CZE-CCD), as decribed in literature, regarding the major cations and anions. An improved CE method for anions was developed to afford the simultaneous determination of HCO3-. Validation of results was made with the reference method of ion chromatography. Although in many samples some analytes are low and close to the quantification limits od CZE-CCD, PT-NLR and CT-NLR, satisfactory agreement was achieved between values obtained by the three techniques for strong acids, weak acids, ammonium and bicarbonate.
|
144 |
Eletroforese capilar como ferramenta analítica para toxicologia forense / Cappilary electrophoresis as analytical tool for forensic toxicologyJosé Luiz da Costa 13 June 2008 (has links)
No primeiro capítulo deste trabalho, são apresentados aspectos gerais sobre toxicologia forense e sobre a eletroforese capilar, onde se buscou mostrar como a técnica analítica pode ser útil para aplicações forenses. O segundo capítulo apresenta o desenvolvimento de metodologia analítica baseada em eletroforese capilar com detecção por arranjo de diodos para determinação de drogas de abuso ou seus produtos de biotransformação em humor vítreo. Foram estudados parâmetros como a composição do eletrólito de corrida (com especial atenção ao fenômeno de eletrodispersão), pré-concentração online (stacking) e modo de extração dos analitos. Foi obtida completa separação eletroforética de 12 analitos investigados em menos de 10 minutos de corrida. Os parâmetros de confiança analítica do método mostraram este é perfeitamente aplicável às análises toxicológicas com finalidade forense. O terceiro capítulo apresenta a elaboração de metodologia analítica baseada em eletroforese capilar acoplada a espectrometria de massas para determinação de cocaína e cinco produtos de biotransformação em urina, com procedimento de preparo da amostra biológica simplificado. O procedimento desenvolvido apresentou sensibilidade adequada para verificação de intoxicações agudas por cocaína, e a espectrometria de massas acrescentou grande seletividade à análise, principalmente quando a detecção foi realizada pela seleção do íon-pai e fragmentos gerados a 34% de energia de colisão. O terceiro capítulo apresenta o desenvolvimento de método simples e rápido para determinação de MDMA em comprimidos de Ecstasy usando eletroforese capilar de zona. Na corrida eletroforética desenvolvida, é possível determinar a concentração de MDMA em menos de dois minutos (usando procaína com padrão interno). O método desenvolvido foi comparado ao utilizado rotineiramente no Núcleo de Análise Instrumental do Instituto de Criminalística de São Paulo, baseado em cromatografia líquida de alta eficiência com detecção por fluorescência. O método eletroforético desenvolvido foi cinco vezes mais rápido do que o método de referência, permitindo maior produtividade sem que houvesse perda da qualidade do resultado. Por fim, o capítulo 4 apresenta as considerações finais deste trabalho, onde se pode concluir que a eletroforese capilar, ainda que pouco utilizada em laboratórios forenses brasileiros, pode ser ferramenta de grande utilidade nas análises toxicológicas destinadas a esta finalidade. / In the first chapter of this thesis, general aspects on forensic toxicology and capillary electrophoresis are presented, aiming to show how the analytical technique can be useful for forensic applications. The second chapter presents the development of analytical methodology based on capillary electrophoresis with diode array detection for determining drugs of abuse and/or their biotransformation products in vitreous humor. Parameters such as the composition of background electrolyte (with special attention to the phenomenon of electrodispersion), online pre-concentration (stacking) and sample preparation procedures were objects of study. The complete electrophoretic separation of 12 investigated analytes was obtained within 10 minutes of run. The validation parameters of the method have shown that this is perfectly applicable to toxicological analyses with forensic purposes. The third chapter presents the elaboration of analytical methodology based on capillary electrophoresis coupled to mass spectrometry for determining cocaine and five biotransformation products in urine, with simple sample preparation. The process developed presented adequate sensitivity for the verification of acute intoxications by cocaine, and mass spectrometry contributed with great selectiveness to the analysis, mainly when the detection was conducted by the selection of the molecular-ion and fragments generated at 34% of collision energy. The fourth chapter presents the development of a simple and quick method for determining MDMA in tablets of Ecstasy using capillary zone electrophoresis. In the running condition, it is possible to determine the concentration of MDMA in less than two minutes (using procaine with internal standard). The method developed was compared with the one routinely used at Núcleo de Análise Instrumental do Instituto de Criminalística de São Paulo, based on high performance liquid chromatography with fluorescence detection. The electrophoretic method developed was five times faster than the reference one, allowing higher productivity without loss of quality in the result. Finally, chapter five presents the final considerations of this thesis, where it is possible to conclude that capillary electrophoresis, even being little utilized in Brazilian forensic laboratories, can be a tool of great utility in toxicological analyses destined to this purpose.
|
145 |
Estudos fundamentais e aplicações envolvendo hormônios esteróides por meio de eletroforese capilar / Fundamental study and applications involving steroids hormones by capillary electrophoresisClaudinei Alves da Silva 18 February 2008 (has links)
No primeiro capitulo deste trabalho, é apresentada a classificação e a importância dos esteróides sexuais para manutenção da vida humana. Na seqüência, o próximo capítulo mostra aspectos gerais sobre eletroforese capilar, tais como modo de operação, terminologia utilizada e considerações sobre o fluxo eletrosmótico e mobilidade eletroforética. O terceiro capítulo exibe um estudo da interação solvente/micela de SDS/soluto, baseado na otimização da geometria da molécula, análise conformacional, com descritores moleculares e modelos de regressão, baseados no coeficiente de partição. Foram realizadas medidas experimentais dos tempos de retenção, de onze esteróides, a partir da MEKC, em eletrólitos modificados por solvente, conforme suas propriedades de seletividade. O efeito do solvente na modulação da retenção do soluto foi discutido em termos da LSER, a qual indicou a concentração total de solvente no meio como o principal fator de controle do tempo de retenção. A separação dos compostos selecionados, na melhor condição, foi testada em um extrato de uma amostra de urina obtida de um voluntário humano - sexo feminino - em fase de puberdade. A composição do eletrólito (20 mmol L-1 SDS, 20% EtOH e 20 mmol L-1 tetraborato de sódio a pH 9,4) proposta pode ser aplicada potencialmente para a determinação de estrógenos em estudos clínicos (0.80% C.V. para tempo de migração e 2.5% C.V. para área do pico, n = 5). Posteriormente, já no quarto capítulo, o uso do planejamento fatorial foi uma forma rápida de otimizar a composição do eletrólito para separar uma mistura-teste com onze esteróides. Uma triagem das variáveis indicou que as concentrações de ACN, SDS e β-CD mais influenciavam a resolução e o tempo de análise. O estudo dos efeitos mostrou que a interação ACN/ β-CD e a ACN mais contribuía para resolução dos pares críticos. O sistema micelar constituído por 20 mmol L-1 SDS, 10% ACN, 5 mmolL-1 β-CD e 20 mmolL-1 TBS, pH 9.2, foi o meio no qual se obteve a melhor resposta em relação à resolução dos pares críticos e tempo de análise Este método foi usado avaliar a presença dos esteróides em extrato etanólico de excrementos de Pantera onca. Em outra etapa um método MEEKC foi desenvolvido e validado para a determinação de 17 β-estradiol em adesivo transdérmico usando uma microemulsão contendo 0.5% (m/m) acetato de etila, 1.2% (m/m) butan-1-ol, 0.6% (m/m) SDS, 15% (v/v) ACN e 82.7% (m/m) TBS 12 mmol L-1 , pH 9.4. Foi obtida aceitável precisão (<1.2% RSD), linearidade, sensibilidade (LOD=0.89 µg/mL; LOQ=2.68 µg/mL) e recuperação (100.4 ±0.9 %). Por fim, o ultimo capítulo traz o desenvolvimento e validação de um método via MEKC para determinação etinilestradiol em comprimidos usando um eletrólito constituído por 20 mmol L-1 SDS, 22,5 % (v/v) ACN e 10 mmol L-1 TBS, pH 9,2. Apresentando valores de precisão (<1.0% RSD), linearidade, sensibilidade (LOD=0.84 µg/mL; LOQ=2.55 µg/mL) e recuperação (99.4± 0.7 %) aceitáveis. E ainda, via MEEKC, para determinação simultânea de etinilestradiol e levonorgestrel usando uma microemulsão contendo: 0.5% (m/m) acetato de etila, 1.2% (m/m) butan-1-ol, 0.6% (m/m) de SDS, 15% (v/v) etanol e 82.7% (m/m) TBS 12 mmol L-1 , pH 9.2. Injeção: pelo outlet 3s/0.5 psi. Com alta precisão (<0.8% RSD), linearidade, sensibilidade (LOD=1.04 µg/mL; LOQ=3.15 µg/mL para etinilestradiol e LOD=1.35 µg/mL; LOQ=4.10 µg/mL para o levonorgestrel) e recuperação (98.6± 0.8 % para etinilestradiol), os métodos mostraram-se sensíveis e precisos para serem utilizados no controle de qualidade de formulações farmacêuticas. / In the first chapter of this work, the classification and importance of the sexual steroids for maintenance of the life human is presented. The next chapter presents general aspects on capillary electrophoresis, such as operation, terminology and considerations on the electroosmotic flow and electroforetic mobility. The third chapter shows a study of interaction solvent/ SDS micelle /solute, based on the optimization of molecule geometry, conformational analysis, with molecular descriptors and regression models, based in the partition coefficient. The retention times were measured experimentally for eleven steroids, in MEKC electrolytes modified by solvents. The solvent effect in modulating the retention of solute was explaned in terms of LSER, which indicated the total organic solvent percentage in the electrolyte as the main factor controlling retention. The separation of selected compounds, in the best condition, was tested in urine extract sample from a human volunteer - feminine -1 sex - in puberty phase. The composition of the proposed electrolyte (20 mmol L-1 SDS, 20% (v/v) EtOH and 20 mmol L-1 sodium tetraborate, pH 9.4) can potentially be applied for determination of estrogens in clinical studies (0.80% C.V. for migration time and 2.5% C.V. for peak area, n = five consecutive injections). Later, in fourth chapter, the use of factorial design was introduced to optimize the composition of the electrolyte to separate a mixture-test with eleven steroids. The selection of variable indicated that the concentrations of ACN, SDS and β-CD influenced the most resolution and analysis time. The study of the effect showed that interaction ACN/ β-CD and ACN were important for resolution of the critical pairs. The micelle system constituted of 20 mmol L-1 SDS, 10% (v/v) ACN, 5 mmolL-1 β-CD and 20 mmolL-1 TBS, pH 9.2, was composition to achieve resolution of the critical pairs and analysis time. This method was used to evaluate the presence of the steroids in fecal ethanolic extract of Pantera onca. In another work a MEEKC method was developed and validated for determination of 17 β-estradiol in transdermical adhesive using a microemulsion containing 0.5% (w/w) ethyl acetate, 1.2% (w/w) butan-1-ol, 0.6% (w/w) sodium dodecyl sulfate, 15% (v/v) ACN and 82.7% (w/w) 12 mmol L-1 sodium tetraborate aqueous buffer at pH 9.4. Acceptable precision (<1.2% RSD), linearity, sensitivity (LOD=0.89 µg/mL; LOQ=2.68 µg/mL) and recovery (100.4± 0.9 % at three concentration levels) were obtained. The last chaper, the development and validation of MEKC method for determination of ethynylestradiol in a commercial tablet formulation using a micellar medium containing, 25 mmol L-1 sodium dodecyl sulfate, 22,5% (v/v) ACN and 10 mmol L-1 sodium tetraborate aqueous buffer at pH 9.2 was presented. Acceptable precision (<1.0% RSD), linearity, sensitivity (LOD=0.84 µg/mL; LOQ=2.55 µg/mL) and recovery (99.8± 1.8 % at three concentration levels) were obtained. A MEEKC method for the simultaneous determination of ethynylestradiol and levonorgestrel using microemulsion containing 0.5% (w/w) ethyl acetate, 1.2% (w/w) butan-1-ol, 0.6% (w/w) sodium dodecyl sulfate, 15% (v/v) ethanol and 82.7% (w/w) 12 mmol L-1 sodium III tetraborate aqueous buffer at pH 9.2 was developed. High precision (<0.8% RSD), linearity, sensitivity (LOD=1.04 µg/mL; LOQ=3.15 µg/mL to ethynylestradiol and LOD=1.35 µg/mL; LOQ=4.10 µg/mL to levonorgestrel) and recovery (98.6± 0.8 % at three concentration levels of ethynylestradiol) were obtained.
|
146 |
Inovações instrumentais em sistemas de eletroforese capilar com detecção eletroquímica e aplicações em análises de mono e oligossacarídeos, aminoácidos e proteínas / Instrumental innovations in capillary electrophoresis with electrochemical detection in the analysis of mono and oligosaccharides, amino acids and proteinsLucas Blanes 27 March 2008 (has links)
A presente tese é o resultado de um complexo trabalho de instrumentação em Eletroforese Capilar (CE) com detecção condutométrica sem contato (C4D) visando à análise de biomoléculas. No que diz respeito à instrumentação, dois equipamentos de CE (H1 e B1), que possuem um sistema único de eletrólise separada (MSE), foram desenvolvidos. H1 possui apenas um capilar, e nele foi desenvolvida a maioria dos experimentos apresentados nesse trabalho. Neste equipamento, foi implementado um sistema de marcas térmicas, cuja aplicação foi demonstrada na correção de variações nos tempos de migração dos íons Na+ e K+ presentes em clara de ovos. Também realizamos a separação e detecção (10 µmol·L-1 ) de proteínas entre 12 e 66 kDa, comprovando que a detecção dessas moléculas é factível, desde que se use agentes que evitem a adsorção. Experimentos de separação e detecção de quitooligossacarídeos produzidos enzimaticamente também foram desenvolvidos em H1. Com o uso de NaOH como eletrólito de corrida acrescido de acetonitrila como agente modificador, verificamos a separação completa de seis quitooligossacarídeos (C1 a C6) com limites de detecção e quantificação inferiores a 3 µmol·L-1 e 10 µmol·L-1 , respectivamente. Após ensaios enzimáticos dos substratos C2 a C6 com a quitinase purificada de um besouro Tenebrio molitor (TmChi), observamos que esta cliva com baixíssima eficiência tanto C2 como C3. A mesma é capaz de clivar C4 produzindo C2 e sua ação sobre C5 gera C2 e C3, sendo este o substrato de maior afinidade. C6 também é clivado por essa quitinase, gerando, contudo, C2 ou C3, o que indica que ela é uma endoquitinase. O equipamento B1 possui oito capilares e oito detectores condutométricos sem contato, possuindo a maior relação sinal/ruído a 1 MHz e 4 Vpico-a-pico. O equipamento possibilita a separação simultânea de até oito amostras distintas com quatro possíveis eletrólitos e potenciais de trabalho. Nesse equipamento, foram desenvolvidas as separações dos vinte aminoácidos proteinogênicos, usando-se duas condições distintas de separação, ambas em meio ácido. Separações em meio básico e com potenciais de separação variados também foram avaliadas. Além dos sistemas H1 e B1, também foi desenvolvido um microchip em PDMS com um biorreator enzimático (IMER) para detecção de glicose. A detecção de peróxido formado pela ação da enzima glicose oxidase presente no IMER foi realizada por amperometria. O chip apresentou as melhores condições de separação e detecção desse açúcar usando-se eletrodo de trabalho a 0,9V, pH 8,5 e separação a 1100 V. Foi verificada uma relação linear entre as concentrações de 0,1 a 6,2 mmol·L-1 de glicose injetada, com relação ao pico de corrente obtido. Com as condições otimizadas do chip, determinou-se a concentração de glicose em amostra de refrigerante, obtendo-se uma concentração de 216 mmol·L-1 , valor semelhante ao obtido em literatura. / This work shows the development of two equipments (H1 and B1) of capillary electrophoresis (CE) with contactless conductivity detection (C4D) applied to the analysis of biomolecules. They have a system named MSE (module for separated electrolysis) that avoids the harmful effect of electrolysis. H1 have only one capillary and the majority of the experiments presented here were developed in this equipment. It also have a system of thermal marks (TM) used to correct the EOF effect on the migration of ions Na+ e K+ in egg white. We also developed the separation and detection of proteins (10 µmol·L-1) between 12 an 66 kDa, showing that C4D can be used to detect these molecules using substances to avoid adsorption on the capillary wall. Experiments of separation and detection of chitooligosaccharides enzymatically produced were also developed in H1. By using NaOH and acetonitrile as the electrolyte, we did the complete separation of six chitooligosaccharides (C1 to C6) with limits of detection and quantification less than 3 µmol·L-1 and 10 µmol·L-1 , respectively. After the enzymatic assays of C2 to C6 with the chitinase purified from the beetle Tenebrio molitor (TmChi), it is observed that this enzyme cut these substrates with very low efficiency, as expected. This enzyme also cut C4 producing C2 and cut C5 producing C2 and C3. C5 is the best substrate for this enzyme. C6 produces C2 and C3, showing that this enzyme is a endo- chitinase type. The equipment B1 has eight capillaries and eight C4D detectors with the best signal/noise ratio at 1 MHz e 4 Vpeak-to-peak . By using B1, it is possible run up to eight different samples with four different electrolytes and separation potentials. In this equipment, we develop the separation of 20 proteinogenic amino acids (AAs) using two different separation conditions at low pH. Separations of these molecules using high-pH electrolytes and with different potentials were also demonstrated. The development of a microchip of PDMS with an immobilized enzyme reactor (IMER) to the glucose detection was also constructed. The detection of hydrogen peroxide produced by the enzyme glucose oxidase linked on the IMER was measured by amperometry. The performance of this chip was evaluated with glucose and peroxide injections. The best potential for the oxidation of the hydrogen peroxide was 0.9V, using electrolyte at pH 8.5 and 1100 V as the potential of separation. A linear curve was observed between peak current and glucose concentration in the range from 0.1 up to 6.2 mmol·L-1 . Determinations in soda shows 216 mmol·L-1 of glucoce, that is a good agreement with other reports.
|
147 |
Determinação de opióides em cabelo via eletroforese capilar (CE) / Determination of opiates in hair by capillary electrophores (CE)Elizabete Campos de Lima 25 April 2003 (has links)
A análise química para a verificação do uso de drogas de abuso vem sendo requisitada com o objetivo de identificar o usuário para que medidas de prevenção e controle possam ser tomadas uma vez que o seu uso está atingindo indivíduos de variadas faixas etárias e camadas sociais. O cabelo é uma matriz biológica interessante de se trabalhar pois não requer cuidados especiais para seu transporte e armazenamento e além disso é de difícil adulteração. O presente projeto de pesquisa teve como objetivo o desenvolvimento de metodologias analíticas altemativas para a separação de 15 opióides, em cabelo, utilizando a eletroforese capilar (CE). Foi desenvolvida uma metodologia de extração inédita para a digestão das amostras de cabelo utilizando-se a extração em fase sólida com cartucho de fase estacionária trocadora de íons (MCX) os extratos obtidos foram analisados via CE utilizando-se com eletrólito de separação tampão fosfato 20 mmol/l, pH 2,5; injeção eletrocinética da amostra (5 s/5 kV); 25 kV durante a análise; detecção em 200 nm e 25°C de temperatura. As análises foram feitas utilizando-se uma coluna capilar de sílica fundida de 75 µm de diâmetro interno, Lt =47 cm e Lefe =40 cm. A metodologia desenvolvida e, especificamente validada para morfina, foi aplicada a um conjunto de 100 amostras da área clínica (cabelo de 35 pacientes sob medicação a base e de morfina). A validação do método proposto para a determinação de morfina em amostras de cabelo apresentou boa linearidade (R > 0,99), valores de limite de detecção e quantificação da ordem de 0,064 mg/L (ou 0,12 ng de morfina/mg de cabelo) e 0,214 mg/L (ou 0,37 ng morfina/mg de cabelo) respectivamente; com precisão e exatidão adequadas (erro relativo < 20%), valores de recuperação média de 81,19 % e com seletividade apropriada e especificidade única testada para 4 principais interferentes (morfina-3βD-glicuronídeo, nalorfina, clonidina e codeína). O nível de morfina nas amostras de cabelo provenientes dos pacientes selecionados (pacientes do Grupo da Dor do Hospital das Clínicas da Universidade de São Paulo - HCFMUSP) variou de 1,3 a 18,4 ng de morfina/mg de cabelo. Além disso, foram otimizadas 2 separações de misturas de opióides um envolvendo os principiais opióides utilizados em clínica médica e outra contendo esses mesmos opiáceos acrescida de seus metabólitos. A primeira mistura de padrões foi separada utilizando-se tampão fosfato 20 mmol/L, pH 2,5. A segunda mistura de padrões foi separada utilizando-se tampão fosfato 60 mmol/L, pH 2,5 contendo 8 mmol/L β-ciclodextrina + 4% metanol. / This work describes a series of studies aiming at the determination of opiates of clinical and forense importance using hair as an alternative biological matrix and capillary electrophoresis (CE) as the technique of choice. Electrolyte compositions were criteriously explored using CE in its diverse modes of operation and the separation of 15 opiates and metabolites (petidine, morphine, tramadol, naloxone, phentanyl citrate, alphentanil HCl, suphentanyl citrate, 6-acetylmorphine, pentazocine, nalorphine, codeine, 6-acetylcodeine, methadone, morphine-3β-D-glucuronide, norphentanyl) was accomplished in less than 14 min using as electrolyte, phosphate buffer 60 mmol/L, pH 2.5 with 8 mmol/L β-ciclodextrine and 8 % methanol in the conditions: inj. 5 s/10 kV, 30 kV during analysis, detection 200nm and 20 °C. Additionally, a comparative evaluation of the strategies for hair extraction and pre-concentration of opiates to contemplate the concentration sensitivity restrains of capillary electrophoresis have been investigated. Recoveries of target analytes (petidine, naloxone, tramadol, fentanyl, alfentanyl and sufentanyl) using liquid-Iiquid extraction and solid-phase extraction employing a variety of solvents and stationary phases were estimated. A novel, simple and reliable strategy for digestion and extraction of morphine in hair was developed based upon acidic hydrolysis (45°C, 12 h) followed by solid-phase extraction in ion-exchange resin cartridges (MCX, Supelco). Recoveries of morphine up to 81.4% were obtained with this procedure. Hair extraets were analyzed via CE using 20 mmol/L phosphate buffer at pH 2.5, electrokinetie injection (5 kV, 5 s), 25 kV applied voltage, detection at 200 nm in a eapillary with dimensions 75 µm i.d., 47 em totallength and 40 em effective length. lhe methodology was validated with respect to precision (CV < 20 %), aecuraey (relative error < 20 %), linearity (r > 0.99), limit of detection and quantifieation, 0.064 mg/L (0.12 ng of morphine per mg of hair) and 0.214 mg/L (0.37 ng of morphine per mg of hair), respectively, with appropriate selectivity and specificity, tested for four major interfering eompounds (morphine-3βD-glucuronide, nalorphine, clonidine and codeine). Hair analyses of over 100 samples from c.a. 35 patients (Grupo da Dor, Hospital das Clínicas, Universidade de São Paulo, HC-FMUSP) suffering from radieular or medullar lesion, receiving morphine by implantable intrathecal systems were eondueted. Levels of morphine in the patients hair was found in the range of 1.3-18.4 ng/mg.
|
148 |
Avaliação da eletroforese capilar para quantificação do nebivolol em forma farmacêutica sólida e análise enantiosseletiva da ligação do nebivolol às proteínas plasmáticas / Evaluation of capillary electrophoresis for the nebivolol quantification in solid pharmaceutical forms and enantioselective analysis of nebivolol binding to plasmatic proteinsAna Débora Nunes Pinheiro 02 March 2015 (has links)
O nebivolol é um fármaco anti-hipertensivo, comercializado na forma de uma mistura equimolar dos enantiômeros RSSS e SRRR-nebivolol. Esses dois enantiômeros possuem propriedades farmacológicas distintas, o que sugere uma farmacocinética diferente entre ambos. Sendo assim, foram desenvolvidos dois métodos para a análise do nebivolol por eletroforese capilar (CE), um aquiral e outro quiral. O primeiro consistiu em um método para análise de forma farmacêutica comercial de comprimidos de nebivolol. Foram definidas as seguintes condições analíticas: capilar de sílica fundida 50 ?m de diâmetro interno (d.i) e 38 cm de comprimento efetivo (c.ef), eletrólito de corrida composto por tampão acetato de sódio 50 mM, pH 4,0, temperatura de 30 °C, tensão de 30 kV e detecção a 200 nm. O método desenvolvido permitiu a análise rápida e eficiente de comprimidos comerciais de nebivolol, sendo simples, seletivo, preciso e exato, está em conformidade com o guia de validação de métodos analíticos da ANVISA (2003), e foi aplicado para quantificação de comprimidos comerciais de nebivolol. O segundo método teve como objetivo realizar a análise enantiosseletiva da ligação do nebivolol à albumina humana do soro (HSA). Após a avaliação de diversos parâmetros, foram estabelecidas as seguintes condições analíticas: capilar de sílica fundida 50 ?m d.i e 38 cm c.ef, eletrólito de corrida composto por tampão acetato de sódio 50 mM, carboxi-metil-?-ciclodextrina 12,5 mM, 1% acetonitrila, pH 4,0, temperatura de 25 oC, tensão de 25 kV e detecção a 200 nm; e como técnica de stacking foi utilizada field amplified sample injection com plug de água (5 psi, 5 s) e injeção eletrocinética 5 kV por 30 s. Nesta condição foi obtida uma resolução de 1,58 e tempo de análise inferior a 25 minutos. No estudo de ligação à HSA foi observado que há enantiosseletividade na ligação, porém, este estudo ainda precisa ser melhor delineado em relação às concentrações de proteína e analito, bem como tempo de incubação e procedimento de filtração para separação das frações livre e ligada / Nebivolol is an anti-hypertensive drug, commercialized as a racemic mixture of RSSS and SRRR-nebivolol. Both enantiomers have distintict pharmacological properties, what suggests a different pharmacokinectis between them. Therefore, it was developed two methods for the nebivolol analysis by capillary electropforesis (CE), one of them is achiral and the other is chiral. The first method aimed the analysis of tablets. The analytical conditions were determined: silica fused capillary 50 ?m internal diameter (i.d.) and 38 cm effective length (ef. l.), running electrolyte composed by 50 mM sodium acetate buffer, pH 4.0, 30 °C temperature, 0 kV applied voltage and 200 nm UV detection. The developed method allowed a quickly and efficient tablets analysis, being simple, selective, accurate and precise, and it is also in accordance with ANVISA (2003) analytical methods validation guide, and it was applied to the quantification of nebivolol in tablets. The second method aimmed to analyze the enantiosselective nebivolol binding to HSA. After the evaluation of many parameters, it was stabilished the following analytical conditions: 50 ?m i.d. and 38 cm ef.l. fused silica capillary, running electrolyte composed by 50 mM sodium acetate buffer, 12.5 mM carboxymethyl- ?-cyclodextrin, acetonytrile 1%, pH 4.0, 25 oC, 25 kV applied voltage and 200 nm UV detection; and as stacking technique it was applied field amplified sample injection with water plug(5 psi, 5 s) and 5 kV por 30 s eletrokinect injection. At this condition, it was possible to achive 1.58 resolution and less than 25 minutes of analysis. At the HSA binding study, it was observed an enantiosselectivity on the binding; however this study still needs better desing in conserne to analyte and protein concentration, as well as, incubation time and filtration proceadure to the separion of binded and free fractions.
|
149 |
Avaliação da microextração líquido-líquido dispersiva para análise de oxibutinina e de N-desetiloxibutinina em urina por eletroforese capilar / Evaluation of dispersive liquid-liquid microextraction for oxybutynin and N-desethyloxybutynin urine analysis by capillary electrophoresisBruna Juliana Moreira 19 October 2012 (has links)
A microextração líquido-líquido dispersiva (DLLME) é uma técnica de preparo de amostra baseada no equilíbrio de distribuição do analito entre a fase doadora (amostra) e a fase aceptora (solvente orgânico) em um sistema ternário de solventes. Foi desenvolvida em 2006 por Rezaee e colaboradores para a determinação de hidrocarbonetos policíclicos aromáticos em amostras de água e por ser uma técnica muito recente,ainda é pouca explorada para o preparo de amostras biológicas. Portanto, o objetivo deste trabalho foi avaliar a DLLME como técnica para a extração da oxibutinina (OXY), fármaco usado para o tratamento da incontinência urinária, e da N-desetiloxibutinina (DEO), seu principal metabólito ativo, em amostras de urina. A análise da OXY e DEO foi realizada por eletroforese capilar (CE), utilizando um capilar de sílica fundida de 50 ?m de diâmetro interno, com comprimento efetivo de 36,5 cm, trietilamina 50 mmol/L, pH 3 como solução de eletrólito, tensão de30 kV, temperatura de 30°C e detecção em 204 nm. Nestas condições o tempo de migração da DEO foi de 7,12 min e da OXY foi de 7,42 min, com resolução de 3,1. O procedimento utilizado para preparo da amostra foi baseado na DLLME, utilizando 5 mL de urina,na qual foi adicionado 2,5% de NaCle cujo pH foi ajustado para 11. O solvente para a extração consistiu de uma mistura de 140 ?L de tetracloreto de carbono (solvente extrator) e 260 ?L de acetonitrila (solvente dispersor), que permaneceram em contato com a amostra pordois minutos. A avaliação das características de desempenho analítico apresentou faixa linear de 90-300 ng/mL para a OXY e 187,5-750ng/mL para a DEO. A recuperação absoluta foi de 71,4 e 60,9% e o limite de quantificação foi de 90 e 187,5 ng/mL para a OXY e DEO, respectivamente. Os estudos de precisão e exatidão apresentaram coeficientes de variação e erros relativos inferiores a 15% e as amostras foram estáveis nos estudos de estabilidade. Portanto, foi possível desenvolver um método rápido, fácil e confiável para analisar e quantificar a OXY e a DEO em amostras de urina por CE, usando a DLLME como técnica de preparo de amostra. / The dispersive liquid-liquid microextraction (DLLME) is a sample preparation technique based on the equilibrium distribution between an extraction solvent and a sample solution in a ternary solvent system. It was developed by Rezaee and co-workers in 2006 for the determination of polycyclic aromatic hydrocarbons in water samples. Until now, for being a very recent technique it was little explored for the analysis of drugs in biological fluids. Therefore, the aim of this work was to evaluate the DLLME as an extraction technique for oxybutynin (OXY), a drug used to treat urinary incontinence, and N-desethyloxybutynin (DEO), its main active metabolite in urine samples. The OXY and DEO\'s analysis was performed by capillary electrophoresis (CE) using a 50 ?m ID fused-silica capillary with an effective length of 36.5 cm with a photodiode array detector set at 204 nm. It made use of triethylamine 50 mmol/L pH 3 as background electrolyte, voltage of +30 kV and temperature of 30°C. Under these conditions the migration time were 7.12 minutes for DEO and 7.42 minutes for OXY, with a resolution of 3.1. The sample preparation procedure was based on DLLME and used 5 mL of urine samples whichionic strength was increased by the addition of 2.5% NaCland pH were adjusted to 11. The extraction mixture consisted of 140 ?L of carbon tetrachloride (extraction solvent) and 260 ?L of acetonitrile (disperser solvent), which remained in contact with the sample for two minutes. The analytical performance\'s evaluation presented linear range of 90-300 ng/mL for OXY and 187.5-750ng/mL for DEO. The absolute recovery were 71.4 and 60.9% and the limit of quantification were 90.0 and 187.5 ng/mL for OXY and DEO, respectively. The accuracy and precision studies showed coefficients of variation and errors below 15% and the samples were stable at stability studies. Therefore, it was possible to develop a fast, reliable and easy method to analyze and quantify OXY and DEO in urine samples by CE, using DLLME as a sample preparation technique.
|
150 |
Análise enantiosseletiva da lercanidipina: controle de qualidade de formulações farmacêuticas por eletroforese capilar e avaliação da fotodegradação por cromatografia líquida de alta eficiência / Enantioselective analysis of lercanidipine: quality control of pharmaceutical by capillary electrophoresis and evaluation of photodegradation by high performance liquid chromatographyLuciana Pereira Lourenço 26 March 2013 (has links)
A lercanidipina (LER) é uma dihidropiridina bloqueadora de canais de cálcio disponível comercialmente como uma mistura racêmica, ou seja, uma mistura equimolar dos enantiômeros (R)-LER e (S)-LER. Os efeitos farmacológicos da LER residem essencialmente no enantiômero (S)-LER, e estudos in vitro mostram que este enantiômero apresenta cerca de 100-200 vezes maior afinidade pelos canais de cálcio que o enantiômero (R)-LER. Consequentemente, os efeitos farmacodinâmicos da LER são devidos, principalmente, ao enantiômero (S)-LER. Neste sentido, fármacos racêmicos são exaustivamente estudados, para avaliar suas propriedades farmacocinéticas e farmacodinâmicas estereosseletivas e verificar se existem vantagens na produção do enantiômero puro. Além disso, devido às diferenças na atividade dos enantiômeros, é imprescindível realizar o controle de qualidade enantiosseletivo destas formulações. Associado a isto, as moléculas pertencentes a esta classe de fármacos são fotossensíveis. Assim, o objetivo deste trabalho foi desenvolver e validar um método enantiosseletivo para análise da LER e aplicá-lo no controle de qualidade de formas farmacêuticas e também avaliar sua fotodegradação. A análise enantiosseletiva da LER e aplicação no controle de qualidade de formas sólidas foi realizado por eletroforese capilar (CE) utilizando tampão acetato de sódio 200 mmol L-1, pH 4,0 como eletrólito de corrida, adicionado de TM-?-CD (2, 3, 6-O-metil-?-ciclodextrina) 10 mmol L-1 como seletor quiral, na temperatura de 15 °C e 25 kV de tensão. Os parâmetros de desempenho analítico, linearidade, precisão, exatidão, limite de quantificação e detecção, seletividade e robustez foram avaliados e estão de acordo com os requisitos preconizados pelos guias oficiais. O método foi aplicado para análise de comprimidos comerciais contendo LER, e mostrou ser adequado para quantificação das amostras, apresentando valores de coeficiente de variação (CV, %) e erro relativo (E, %) inferiores a 5 %. Além disso, foi avaliada a fotoestabilidade dos enantiômeros da LER na mistura racêmica e também dos enantiômeros separados, quando expostos à luz UVC (254 nm) e visível, por HPLC. A separação dos enantiômeros da LER foi alcançada empregando a coluna quiral Chiralpak® AD 250 × 4,6 mm, partículas de 10 ?m e fase móvel composta por hexano-etanol-dietilamina (97:3:0,3, v/v/v) e vazão de 1,0 mL min-1. O método foi validado e aplicado nos estudos de fotodegradação em soluçãos-padrão de LER. Em relação à exposição na luz UVC (254 nm) e visível foi observada degradação significativa dos enantiômeros da LER após 0,5 h de exposição. Além disso, os produtos de degradação foram caracterizados por LC/MS/MS e foi observada que a principal fragmentação ocorre no anel dihidropiridínico, assim como para outros fármacos desta classe, formando piridinas sem efeitos farmacológicos. / Lercanidipine (LER) is a dihydropyridine calcium channel blocker commercially available as a racemic mixture, or an equimolar mixture of enantiomers (R) and LER (S)-LER. The pharmacological effects of LER essentially reside in the enantiomer (S)-LER, and in vitro studies show that this enantiomer has about 100-200 times greater affinity for calcium channels that the enantiomer (R)-LER. Consequently, the pharmacodynamic effects of LER are due mainly to the enantiomer (S)-LER. Thus, racemic drugs are extensively studied to evaluate their pharmacokinetic and pharmacodynamic properties stereoselective and check if there are advantages in the production of pure enantiomer. Moreover, due to differences in the activity of the enantiomers is essential to perform quality control enantioselective these formulations. Additonally, the molecules of this class of drugs are photosensitive. The objective of this study was to develop and validate a method for enantioselective analysis of LER and apply it in the quality control of pharmaceutical forms and also evaluate their photodegradation. The enantioselective analysis of LER and application in quality control of solid forms was performed by capillary electrophoresis (CE) using sodium acetate buffer 200 mmol L-1, pH 4.0 as background electrolyte, 10 mmol L-1TM-?-CD (2, 3, 6-O-methyl-?-cyclodextrin) as chiral selector, at temperature of 15 °C and 25 kV voltage. The analytical parameters, linearity, precision, accuracy, limit of quantification and detection, selectivity and robustness were evaluated and accordance with the requirements recommended by official guideline. The method was applied for the analysis of commercial tablets containing LER, and proved to be suitable for quantification of the samples, with of CV (%) and E (%) less than 5%. In addition, the photostability was evaluated on the LER enantiomers and racemic mixture of the enantiomers also separated when exposed to UVC (254 nm) and visible light by HPLC. Separation of enantiomers of LER was achieved using the chiral column Chiralpak ® AD 250 × 4.6 mm, particles of 10 micrometres and a mobile phase composed of hexane-ethanol-diethylamine (97:3:0.3 v/v/v ) and flow rate of 1.0 mL min-1. The method was validated and applied in studies of photodegradation of standard solutions of LER. The method was validated and applied in studies of photodegradation in soluçãos standard of LERR With relation to UVC exposure (254 nm) and visible light, significant degradation was observed after 0.5 hour exposure of the solution containing the racemic mixture and after 1 h of exposure the solution containing the isolated enantiomers of LER. Also, the degradation products were characterized by LC/MS/MS and it was observed that the major fragmentation occurs in dihydropyridine ring, as well as other drugs of this class, forming pyridines no pharmacological effects.
|
Page generated in 0.0751 seconds