• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 265
  • 1
  • Tagged with
  • 268
  • 268
  • 213
  • 212
  • 80
  • 73
  • 73
  • 53
  • 48
  • 44
  • 43
  • 42
  • 39
  • 34
  • 32
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Avaliação da microextração líquido-líquido dispersiva para análise de oxibutinina e de N-desetiloxibutinina em urina por eletroforese capilar / Evaluation of dispersive liquid-liquid microextraction for oxybutynin and N-desethyloxybutynin urine analysis by capillary electrophoresis

Moreira, Bruna Juliana 19 October 2012 (has links)
A microextração líquido-líquido dispersiva (DLLME) é uma técnica de preparo de amostra baseada no equilíbrio de distribuição do analito entre a fase doadora (amostra) e a fase aceptora (solvente orgânico) em um sistema ternário de solventes. Foi desenvolvida em 2006 por Rezaee e colaboradores para a determinação de hidrocarbonetos policíclicos aromáticos em amostras de água e por ser uma técnica muito recente,ainda é pouca explorada para o preparo de amostras biológicas. Portanto, o objetivo deste trabalho foi avaliar a DLLME como técnica para a extração da oxibutinina (OXY), fármaco usado para o tratamento da incontinência urinária, e da N-desetiloxibutinina (DEO), seu principal metabólito ativo, em amostras de urina. A análise da OXY e DEO foi realizada por eletroforese capilar (CE), utilizando um capilar de sílica fundida de 50 ?m de diâmetro interno, com comprimento efetivo de 36,5 cm, trietilamina 50 mmol/L, pH 3 como solução de eletrólito, tensão de30 kV, temperatura de 30°C e detecção em 204 nm. Nestas condições o tempo de migração da DEO foi de 7,12 min e da OXY foi de 7,42 min, com resolução de 3,1. O procedimento utilizado para preparo da amostra foi baseado na DLLME, utilizando 5 mL de urina,na qual foi adicionado 2,5% de NaCle cujo pH foi ajustado para 11. O solvente para a extração consistiu de uma mistura de 140 ?L de tetracloreto de carbono (solvente extrator) e 260 ?L de acetonitrila (solvente dispersor), que permaneceram em contato com a amostra pordois minutos. A avaliação das características de desempenho analítico apresentou faixa linear de 90-300 ng/mL para a OXY e 187,5-750ng/mL para a DEO. A recuperação absoluta foi de 71,4 e 60,9% e o limite de quantificação foi de 90 e 187,5 ng/mL para a OXY e DEO, respectivamente. Os estudos de precisão e exatidão apresentaram coeficientes de variação e erros relativos inferiores a 15% e as amostras foram estáveis nos estudos de estabilidade. Portanto, foi possível desenvolver um método rápido, fácil e confiável para analisar e quantificar a OXY e a DEO em amostras de urina por CE, usando a DLLME como técnica de preparo de amostra. / The dispersive liquid-liquid microextraction (DLLME) is a sample preparation technique based on the equilibrium distribution between an extraction solvent and a sample solution in a ternary solvent system. It was developed by Rezaee and co-workers in 2006 for the determination of polycyclic aromatic hydrocarbons in water samples. Until now, for being a very recent technique it was little explored for the analysis of drugs in biological fluids. Therefore, the aim of this work was to evaluate the DLLME as an extraction technique for oxybutynin (OXY), a drug used to treat urinary incontinence, and N-desethyloxybutynin (DEO), its main active metabolite in urine samples. The OXY and DEO\'s analysis was performed by capillary electrophoresis (CE) using a 50 ?m ID fused-silica capillary with an effective length of 36.5 cm with a photodiode array detector set at 204 nm. It made use of triethylamine 50 mmol/L pH 3 as background electrolyte, voltage of +30 kV and temperature of 30°C. Under these conditions the migration time were 7.12 minutes for DEO and 7.42 minutes for OXY, with a resolution of 3.1. The sample preparation procedure was based on DLLME and used 5 mL of urine samples whichionic strength was increased by the addition of 2.5% NaCland pH were adjusted to 11. The extraction mixture consisted of 140 ?L of carbon tetrachloride (extraction solvent) and 260 ?L of acetonitrile (disperser solvent), which remained in contact with the sample for two minutes. The analytical performance\'s evaluation presented linear range of 90-300 ng/mL for OXY and 187.5-750ng/mL for DEO. The absolute recovery were 71.4 and 60.9% and the limit of quantification were 90.0 and 187.5 ng/mL for OXY and DEO, respectively. The accuracy and precision studies showed coefficients of variation and errors below 15% and the samples were stable at stability studies. Therefore, it was possible to develop a fast, reliable and easy method to analyze and quantify OXY and DEO in urine samples by CE, using DLLME as a sample preparation technique.
112

Validação de métodos para análise de citrato de colina e acetilmetionina em soluções injetáveis por cromatografia líquida de alta eficiência e eletroforese capilar / Validation of methods for analysis of choline citrate and acetylmethionine in injectable solutions by high performance liquid chromatography and capillary electrophoresis.

Alexandre, Grazielle Prado 11 February 2011 (has links)
O objetivo desta pesquisa foi desenvolver, validar e comparar métodos analíticos para separação e quantificação de citrato de colina e acetilmetionina em formulações injetáveis por cromatografia líquida de alta eficiência (CLAE) e eletroforese capilar (EC). O método por CLAE, com o qual foi possível quantificar e separar simultaneamente, o citrato de colina e a acetilmetionina, foi realizado empregando-se uma coluna cromatográfica C18, 250 x 4,6 mm, 5µm, Shim-Pack® VP-ODS e fase móvel constituída por tampão fosfato de potássio 25 mM pH 5,7: acetonitrila: metanol (88:10:2 v/v/v). O método por EC foi validado utilizando-se como eletrólito, tampão de tetraborato de sódio 20 mM a pH 9,2 e capilar de sílica fundida de 40,2 cm, sendo 30 cm efetivos, com 75 µm de diâmetro interno. O método por CLAE apresentou um coeficiente de correlação (r) de 0,9996 para o citrato de colina e 0,9998 para a acetilmetionina. No método por EC, o coeficiente de correlação (r) encontrado foi de 0,9996 para a acetilmetionina. Os métodos podem ser considerados eficientes e confiáveis para serem empregados em análises de rotina de controle de qualidade de soluções injetáveis contendo a associação dos dois fármacos selecionados para o estudo. / The objective of this research was to develop, to validate and to compare two analytical methods for separation and quantification of choline citrate and acetylmethionine in injectable formulations by high performance liquid chromatography (HPLC) and capillary electrophoresis (CE). The HPLC method which enables the separation and simultaneous quantitative determination of choline citrate and acetylmethionine was performed using a C18, 250 x 4.6 mm, 5µm-Shim-Pack®VP-ODS column and a mobile phase constituted of buffer 25 mM potassium phosphate, pH 5.7: acetonitrile: methanol (88:10:2 v/v/v). The CE method was validated using a solution of 20 mM sodium tetraborate buffer pH 9.2 as the electrolyte and a fused silica capillary of 40.2 cm, with 30 cm effective, and 75 mm of diameter. The HPLC method showed a correlation coefficient (r) of 0.9996 for choline citrate and 0.9998 for acetylmethionine. For CE method the correlation coefficient (r) was found to be 0.9996 for acetylmethionine. The methods showed to be efficient and reliable methods, and can be used in routine analysis for quality control of injectable solutions containing the association of the two compounds selected to be studied in this research.
113

Desenvolvimento de métodos para determinação de aminas aromáticas em amostras têxteis por eletroforese capilar / Development of methodology for determination of aromatic amines in textiles matrices by capillary electrophoresis

Aline Klassen 19 March 2012 (has links)
Os corantes que apresentam grupos cromóforos do tipo azo (N=N) são amplamente empregados em numerosas aplicações na indústria, para colorir vários bens de consumo, dentre eles os têxteis. Entretanto, pelo fato de formarem aminas aromáticas carcinogênicas, quando a ligação N=N é rompida, seu uso está sujeito à legislação. Levando em consideração o potencial carcinogênico das aminas aromáticas, a quantificação das mesmas em produtos destinados à exportação se faz necessária. A técnica padrão para o monitoramento da presença dessas aminas em bens de consumo como os têxteis é a cromatografia líquida de alta eficiência, entretanto como alternativa tem-se a eletroforese capilar. Assim, neste trabalho 20 aminas aromáticas oriundas de azo corantes, banidas pela Comunidade Européia por meio da Diretiva 2002/61/EC, foram separadas por meio de eletroforese capilar (CE), com detecção no UV-Vis, e, a confirmação da presença dessas aminas em matrizes têxteis foi realizada por um método confirmatório de LC-MS, adaptado da literatura. Em CE o conhecimento das constantes de dissociação ácido-base se faz necessário para a otimização do pH ideal de corrida, assim estas, bem como mobilidades iônicas para cada uma das aminas aromáticas foram determinadas por meio de curvas de mobilidade efetiva em função do pH. O pH ótimo de separação de 2,50 foi determinado por meio do simulador de separação desenvolvido no grupo (SIMLACE). Dos métodos de separação estudados, o que apresentou maior número de aminas separadas (16 aminas) em linha de base em menor tempo (12 min) foi empregando um BGE composto apenas de 70 mmol/L de dihidrogenofosfato de sódio ajustado a pH 2,50 com ácido fosfórico, considerando um condicionamento de capilar de início de trabalho de 10 minutos de flush com BGE (dihidrogenofosfato de sódio 70 mmol/L ajustado a pH 2,50 com ácido fosfórico, contendo trietilamina 12,3 mmol/L) a uma pressão de 950 mbar, seguido da aplicação de uma tensão de +30 kV por 10 minutos; e um condicionamento entre réplicas de corrida eletroforética de 1 minuto de HCl 0,1mol/L (950 mbar) seguidos de 1 minuto de H2O (950 mbar). A extração das aminas da matriz têxtil envolve três etapas: a redução da ligação N=N, extração das aminas formadas e um posterior clean up e pre-concentração, sendo que para este último o sistema que apresentou melhor resposta em termos de eficiência de extração (da ordem de 100%) foi com o uso de extração em fase sólida com resina de troca catiônica. Por outro lado, a extração das aminas 1, 7 e 8 da matriz têxtil foi obtida por ultrassom após o estudo de um planejamento fatorial de superfície de resposta, a uma temperatura de 52 ºC, tempo de ultrassom de 5 minutos e concentração de HCl de 0,77 mol/L, com recuperações de 105 a 115%. Como figuras de mérito do método otimizado tem-se: linearidade no intervalo de 50,11 409,1 mmol/L (R2 > 0,98), LD (2,43 6,70 mmol/L) e LQ (8,10 22,3 mmol/L), precisão (0,23 27,6%), robustez (por planejamento fatorial), seletividade, especificidade (estudos de estresse com extrato da amostra) e recuperação (valores acima). O método validado foi aplicado a sete amostras adquiridas no mercado local. Dentre elas, duas apresentaram picos com tempos de migração e espectros semelhantes às aminas 5, 7 e 15, sendo que as aminas 7 e 15 foram confirmadas por meio do método de LC-MS/MS adaptado da literatura o qual permitiu a caracterização dessas aminas nas matrizes têxteis analisadas. / The dyes which have chromophoric groups like azo (N = N) are widely used in numerous applications in industry to color various consumer goods, including textiles. However, because of carcinogenic aromatic amines formed when N=N bond is broken, its use is subject to the legislation. Considering the carcinogenic potential of aromatic amines, to quantify them in products intended for export, is needed. The standard technique for monitoring the presence of these amines in consumer goods such as textiles is a high performance liquid chromatography, however the capillary electrophoresis technique can be a good alternative. In this work 20 aromatic amines derived from azo dyes, banned by the European Community by Directive 2002/61/EC, were separated by capillary electrophoresis (CE) with UV-Vis detection, and confirmation of the presence these amines textile matrix was conducted by a method confirmatory LC-MS, adapted from the literature. The knowledge of the dissociation constant acid-base (pKa) in CE technique is necessary to obtain the optimum pH for the separation. In these way the pKa as well as the ionic mobilities for each aromatic amines were determined by curves of effective mobility as a function of pH. The optimum pH for the separation was 2.50 as determined by the simulator separation developed in the group (SIMLACE). About the separation methods studied, which had a higher number of separate amines (16 amines) in the baseline in a shorter time (12 min) employing a BGE composed only of 70 mmol/L sodium dihydrogen phosphate adjusted to pH 2.50 with phosphoric acid, with a conditioning capillary either at the beginning of the working day (10 minutes flush with BGE (sodium dihydrogen 70 mmol/L adjusted to pH 2.50 with phosphoric acid, triethylamine containing 12.3 mmol/L) at a pressure 950 mbar followed by applying a voltage of +30 kV for 10 minutes) and among replicas (1 minute of HCl 0.1 mol/L (950 mbar) followed by 1 minute of H2O (950 mbar)). The extraction of amines textile matrix involves three steps: reduction of N = N bond, extraction of the amines formed and a subsequent clean up and pre-concentration. About the latter step, the best response in terms of extraction efficiency (about 100%) was obtained using solid phase extraction (SPE) with cationic exchange resin. In addition, the best condition for ultrasound extraction of the amines 1, 7 and 8, was determined by means of a response surface factorial design with three variables and two levels. The optimum condition was: temperature of 52 °C, application of ultrasound for 5 min and HCl concentration of 0.77 mol/L, with recoveries of 105% to 115%. Figures of merit for optimized method include: linearity in the range from 50.11 to 409.1 mmol/L (R2> 0.98), LD (limit of detection, 2.43 to 6.70 mmol/L) and LQ (limit of quantification, 8.10 to 22.3 mmol/L), precision (0.23 to 27.6%), robustness (established by a factorial design), selectivity, specificity (stress studies with real sample extracts) and recovery (listed above). The validated method was applied to seven samples purchased at local markets. Among them, two presented peaks with migration times and spectra similar the amines 5, 7, 12 and 15. But, in only one sample the amines 7 and 15 were confirmed by LC-MS/MS.
114

Análise da influência de condições experimentais sobre o comportamento eletroquímico e a distribuição dos produtos da oxidação eletroquímica de glicerol / Analysis of the influence of experimental conditions on electrochemical behavior and the distribution of products obtained by electrooxidation of glycerol

Wanderson Sirley Reis Teixeira 14 August 2015 (has links)
O glicerol, 1,2,3-propanotriol, é o principal subproduto da indústria do biodiesel, cerca de 10% em massa. Apesar das inúmeras aplicações que o glicerol tem na indústria, a oferta desse poliálcool, devido ao grande aumento da produção de biodiesel nos últimos anos, tem crescido tanto que o produto tem se acumulado nas usinas, levando a um desequilíbrio entre produção e consumo. Dessa forma, muita pesquisa vem sendo feita na tentativa de utilizar essa abundante, barata e não tóxica matéria prima como base para a obtenção de energia e outros produtos de maior valor agregado. Dentre os vários processos para a conversão do glicerol, a eletro-oxidação recebe atenção especial devido à sua versatilidade, simplicidade e baixo custo. Neste trabalho, utilizou-se a voltametria cíclica para a análise do comportamento eletroquímico do glicerol e dos possíveis produtos obtidos pela sua eletro-oxidação sobre diversos eletrodos e a influência de variáveis experimentais, tais como, solvente, eletrólito de suporte, concentrações de substrato e eletrólito de suporte, na atividade eletrocatalítica do sistema. As técnicas de eletroforese capilar, coulometria e voltametria cíclica foram utilizadas para a determinação da taxa de conversão e análise quantitativa do glicerol e dos produtos obtidos por meio de eletrólise exaustiva e como esses parâmetros são influenciados pelas variáveis experimentais. Além disso, é importante citar que o método analítico baseado na técnica de eletroforese capilar com detecção condutométrica sem contato foi desenvolvido e otimizado durante o projeto de mestrado e tem grande relevância para este trabalho / Glycerol, 1,2,3-propanetriol, is the main by-product of biodiesel industry, around 10% w/w. Despite of several glycerol applications in industry, the offer of this polyalcohol has increased so much in the last years that it has accumulated in the mills, leading to an unbalance between its production and consumption. Thus, a lot of research has been done trying to use this abundant, cheap and non-toxic raw material as the basis for energy production and synthesis of other more value-added compounds. Among the several conversion processes, the electrooxidation has drawn attention due to its versatility, simplicity and low cost. Cyclic voltammetry is used for analyzing the electrochemical behavior of glycerol and the possible electroconversion products on several electrodes, as well as the influence of experimental variables, such as, solvent, supporting electrolyte and its concentration, substrate concentration on the electrocatalytic activity of the system. Capillary electrophoresis, coulometry and cyclic voltammetry were used for determination of rate conversion and quantitative analyses of glycerol and the obtained products through bulk electrolysis and how these parameters are influenced by experimental conditions. Besides, it is noteworthy that the analytical method based on capillary electrophoresis technique with contactless conductometric detection was developed and optimized along this Master project and it has large relevance for this work.
115

Desenvolvimento de um sistema de análise de compostos voláteis ionizáveis por eletroforese capilar combinando técnicas de microfabricação / Development of an analysis system for ionizable gases using capillary electrophoresis combining conventional and microfabrication techniques

Eric Tavares da Costa 13 November 2013 (has links)
O desenvolvimento de um equipamento de eletroforese capilar com detecção condutométrica sem contato e hifenizado a um sistema de amostragem de gases é apresentado. Ele foi construído a partir de chapas de poli(metacrilato de metila) por ablação a laser de CO2, mesclando métodos convencionais com os de microfabricação. Este protótipo traz como inovações: (1) a refrigeração em estado sólido da coluna capilar, (2) a inclusão de eletrólise separada em microdispositivos e (3) a montagem de uma válvula embutida no microchip, baseada em servomotor. O equipamento é portátil (31 × 29 × 25 cm) e projetado para ser utilizado em bancada ou embarcado num robô para análises remotas de agentes neurotóxicos e outros gases ionizáveis em contato com a fase aquosa. O sistema de termostatização permitiu o controle da temperatura interna do capilar de sílica fundida entre 12 e 50 °C utilizando uma elemento Peltier a a partir da temperatura ambiente de 21 °C. A amostragem de gases é feita utilizando-se uma membrana tubular porosa acoplada ao sistema microfluídico. Ela possui 10 cm de comprimento com 300 micrometros de diâmetro externo e 3,1 microlitros de volume interno. Como prova de conceito, foram feitas amostragens de ar contendo ácidos fórmico, acético e propiônico, separação por eletroforese capilar dos respectivos ânions e detecção com relação sinal-ruído de 414, 150 e 115, respectivamente. A amostragem foi realizada por 30 s e a injeção eletrocinética, por 2 s a 1 kV. A corrida eletroforética foi concluída em 4 min. / The development of a capillary electrophoresis equipment with contactless conductivity detection coupled to a gas sampling system is described. It was constructed from poly(methyl methacrylate) by carbon dioxide laser ablation, using conventional methods and microfabrication. The innovations are: (1) solid-state cooling system of the silica capillary, (2) the inclusion of separate electrolysis on a microdevices, and (3) a valve assembly embedded in the microchip based servomotor. It is portable (31 × 29 × 25 cm) and designed to be used on a workbench or embedded in a robot for remote analysis of nerve agents and other ionized gases. The thermostating system allowed the temperature control of the fused silica capillary between 12 and 50 °C using a Peltier chip from ambient temperature of 21°C. Gas sampling is performed using a tubular porous membrane coupled to the microfluidic system. It is 10 cm long with outer diameter of 300 micrometers and 3.1 microliters of internal volume. Air containing formic, acetic, and propionic acids were sampled, and the corresponding anions were separated and detected in the equipment as a proof of concept. The signal-to-noise ratio were, respectively, 414, 150, and 115, after sampling by 30 s and electrokinetic injection by 2 s at 1 kV. The electrophoretic run was accomplished in 4 min.
116

Determinação simultânea de etinilestradiol e drospirenona em contraceptivos orais por cromatografia e fase líquida de alta eficiência e eletroforese capilar / Simultaneous determination of ethinyl estradiol and drospirenone in oral contraceptive by high performance liquid chromatography and cappilary electrophoresis

Silva, Viviane Benevenuti 13 November 2012 (has links)
O controle da fertilidade é obtido principalmente pela inibição da ovulação por meio da atividade combinada de dois componentes principais: estrogênio e progestina. Desta forma, novas formulações vêm sendo desenvolvidas com baixa dose de etinilestradiol associado a um novo agente progestógeno, a drospirenona, com o objetivo de garantir equilíbrio entre eficácia, segurança e controle de ciclo menstrual. Este trabalho tem como objetivo desenvolver, validar e comparar métodos analíticos para a identificação e quantificação de etinilestardiol e drospirenona presentes em uma mesma formulação por cromatografia em fase líquida de alta eficiência (CLAE) e a eletroforese capilar (EC). O método por CLAE, foi realizado empregando-se uma coluna LiChoCART® 100RP - C18, (125 x 4 mm) 5 µm, fase móvel constituída por MeCN/H2O 50:50 (v/v) e vazão de 1.0 mL min. Utilizou-se um detector UV 200 nm para drospirenona e um de fluorescência λex = 280 nm e λem = 310 nm, para o etinilestradiol. O método por EC foi validado utilizando-se como eletrólito, tampão de tetraborato de sódio 30 mM, dodecil sulfato de sódio 20 mM e acetonitrila 30% a pH 9,2, capilar de sílica fundida de 31,2 cm sendo 21 cm efetivos, com 75 µm de diâmetro interno. O método por CLAE apresentou um coeficiente de correlação (r2) de 0,9989 para o etinilestradiol e 0,999 para a drospirenona. No método por EC, o coeficiente de correlação (r2) encontrado foi de 0,9988 para o etinilestradiol e 0,998 para a drospirenona. Os métodos podem ser considerados eficientes e confiáveis para serem empregados em análise de rotina para controle de qualidade destes produtos farmacêuticos. / The fertility control is achieved mainly by inhibiting ovulation through the combined activity of two main components: estrogen and progestin. Thus, new formulations have been developed associating appropriately low dose of ethinylestradiol to a new drug, the drospirenone, in order to ensure the balance between efficacy, safety and cycle control. The objective of this research was to develop, to validate and to compare two analytical method for separation and quantification of ethinylestardiol and drospirenone using high performance liquid chromatography and capillary electrophoresis (CE). The HPLC method, was performed using a LiChoCART® 100RP - C18, (125 x 4 mm) 5 µm column, a mobile phase constituted of acetonitrile:water (50:50 v/v) and flow rate of 1.0 mL min. UV detection was made for drospirenone at 200 nm coupled with a fluorescence detector at λex= 280 nm and λem = 310 nm for ethinylestradiol. The CE method was validated using a solution of sodium tetraborate buffer 30 mM, sodium dodecil sulphate 20 mM and acetonitrile 30%, pH 9.2 and a fused silica capillary of 31,2 cm with 21 cm effective and 75 µm of diameter. The HPLC method showed a correlation coefficient (r2) of 0.9989 for ethinylestradiol and 0,999 for drospirenone. For CE method, the correlation coefficient was (r2) 0,9988 for ethinylestradiol and 0,9989 for drospirenone. The methods showed to be efficient and reliable, and can be used in routine analysis for quality control of these pharmaceutical preparations.
117

Análise do mesilato de imatinibe em plasma empregando a eletroforese capilar / Determination of imatinib mesylate in plasma by capillary electrophoresis

Ajimura, Tatiana Okura 22 November 2010 (has links)
O mesilato de imatinibe é um importante fármaco pertencente à classe dos inibidores da tirosina-quinase, desenvolvido e utilizado atualmente no tratamento da Leucemia Mielóide Crônica. No histórico da utilização deste medicamento, casos de resistência tem sido relatados cujos mecanismos envolvidos, além dos mecanismos celulares, podem estar relacionados ao metabolismo aumentado deste fármaco. O imatinibe é metabolizado principalmente pelo CYP 3A4, cuja atividade enzimática apresenta grande variabilidade interindividual e é suscetível a indução ou inibição por inúmeras co-medicações, constituintes ambientais e dietéticos. Sendo assim uma dose do medicamento pode resultar em concentrações plasmáticas muito diferentes entre pacientes. A maior parte dos métodos existentes para a determinação do imatinibe em amostras biológicas utiliza a cromatografia líquida de alta eficiência. Entretanto, o método desenvolvido e validado neste trabalho propôs a utilização da eletroforese capilar para a análise deste fármaco em plasma. Para isto foi utilizado um capilar de sílica fundida (46,5 cm de comprimento total, 38 cm de comprimento efetivo e 50 µm de diâmetro interno), tampão fosfato de sódio 50 mmol/L, pH 2,5 como eletrólito de corrida, injeção hidrodinâmica por 20 s a pressão de 50 mbar, tensão de 30 kV, temperatura de 35 °C e detecção em 200 nm. O procedimento de preparo das amostras foi baseado na extração líquido-líquido com o éter metil-terc-butílico como solvente extrator. Os parâmetros de desempenho analítico, linearidade, precisão, exatidão, recuperação, limite de quantificação, seletividade e estabilidade, avaliados na validação do método, cumpriram os requisitos preconizados na legislação vigente e o método desenvolvido foi validado com sucesso. Além disso, sua aplicação foi demonstrada na análise de amostras de plasma de pacientes portadores de Leucemia Mielóide Crônica. / Imatinib mesylate is an important tyrosine kinase inhibitor that has been used for the treatment of Chronic Myeloid Leukemia (CML). Despite the efficacy of imatinib therap, some cases of treatment resistance have been described. A number of mechanisms of resistance have been identified, which include innate or acquired mutations in the BCR-ABL gene, imatinib binding to 1- acid glycoprotein and altered imatinib pharmacokinetics. Imatinib is mainly metabolized by CYP 3A4, whose enzymatic activity presents a large inter-individual variability and is susceptible to induction or inhibition by numerous co-medications, environmental and dietary constituents. Therefore a given dose can yield very different circulating concentrations between patients. The major of methods available for the determination of imatinib in biological samples apply high performance liquid chromatography as analytical technique. However, in this work, we developed and validated a method by capillary electrophoresis for the determination of this drug in human plasma. The analysis was performed using a fused silica capillary (50 µm internal diameter x 46.5 cm total length, 38.0 cm effective length), a 50 mmol/L sodium phosphate buffer pH 2,5 as background electrolyte, hydrodynamic injection time of 20s (50 mbar), voltage of 30 kV, capillary temperature of 35°C and detection at 200 nm. Plasma samples pre-treatment involved liquid-liquid extraction with methyl-terc-butyl ether as extractor solvent. The analytical parameters investigated, linearity, precision, accuracy, recovery, limit of quantification, selectivity and stability, presented in accordance with the confidence criteria established in the literature. Furthermore the application of the method was performed in the analysis of plasma samples from CML patients undergoing treatment with imatinib.
118

Determinação simultânea de etinilestradiol e drospirenona em contraceptivos orais por cromatografia e fase líquida de alta eficiência e eletroforese capilar / Simultaneous determination of ethinyl estradiol and drospirenone in oral contraceptive by high performance liquid chromatography and cappilary electrophoresis

Viviane Benevenuti Silva 13 November 2012 (has links)
O controle da fertilidade é obtido principalmente pela inibição da ovulação por meio da atividade combinada de dois componentes principais: estrogênio e progestina. Desta forma, novas formulações vêm sendo desenvolvidas com baixa dose de etinilestradiol associado a um novo agente progestógeno, a drospirenona, com o objetivo de garantir equilíbrio entre eficácia, segurança e controle de ciclo menstrual. Este trabalho tem como objetivo desenvolver, validar e comparar métodos analíticos para a identificação e quantificação de etinilestardiol e drospirenona presentes em uma mesma formulação por cromatografia em fase líquida de alta eficiência (CLAE) e a eletroforese capilar (EC). O método por CLAE, foi realizado empregando-se uma coluna LiChoCART® 100RP - C18, (125 x 4 mm) 5 µm, fase móvel constituída por MeCN/H2O 50:50 (v/v) e vazão de 1.0 mL min. Utilizou-se um detector UV 200 nm para drospirenona e um de fluorescência λex = 280 nm e λem = 310 nm, para o etinilestradiol. O método por EC foi validado utilizando-se como eletrólito, tampão de tetraborato de sódio 30 mM, dodecil sulfato de sódio 20 mM e acetonitrila 30% a pH 9,2, capilar de sílica fundida de 31,2 cm sendo 21 cm efetivos, com 75 µm de diâmetro interno. O método por CLAE apresentou um coeficiente de correlação (r2) de 0,9989 para o etinilestradiol e 0,999 para a drospirenona. No método por EC, o coeficiente de correlação (r2) encontrado foi de 0,9988 para o etinilestradiol e 0,998 para a drospirenona. Os métodos podem ser considerados eficientes e confiáveis para serem empregados em análise de rotina para controle de qualidade destes produtos farmacêuticos. / The fertility control is achieved mainly by inhibiting ovulation through the combined activity of two main components: estrogen and progestin. Thus, new formulations have been developed associating appropriately low dose of ethinylestradiol to a new drug, the drospirenone, in order to ensure the balance between efficacy, safety and cycle control. The objective of this research was to develop, to validate and to compare two analytical method for separation and quantification of ethinylestardiol and drospirenone using high performance liquid chromatography and capillary electrophoresis (CE). The HPLC method, was performed using a LiChoCART® 100RP - C18, (125 x 4 mm) 5 µm column, a mobile phase constituted of acetonitrile:water (50:50 v/v) and flow rate of 1.0 mL min. UV detection was made for drospirenone at 200 nm coupled with a fluorescence detector at λex= 280 nm and λem = 310 nm for ethinylestradiol. The CE method was validated using a solution of sodium tetraborate buffer 30 mM, sodium dodecil sulphate 20 mM and acetonitrile 30%, pH 9.2 and a fused silica capillary of 31,2 cm with 21 cm effective and 75 µm of diameter. The HPLC method showed a correlation coefficient (r2) of 0.9989 for ethinylestradiol and 0,999 for drospirenone. For CE method, the correlation coefficient was (r2) 0,9988 for ethinylestradiol and 0,9989 for drospirenone. The methods showed to be efficient and reliable, and can be used in routine analysis for quality control of these pharmaceutical preparations.
119

Validação de métodos para análise de citrato de colina e acetilmetionina em soluções injetáveis por cromatografia líquida de alta eficiência e eletroforese capilar / Validation of methods for analysis of choline citrate and acetylmethionine in injectable solutions by high performance liquid chromatography and capillary electrophoresis.

Grazielle Prado Alexandre 11 February 2011 (has links)
O objetivo desta pesquisa foi desenvolver, validar e comparar métodos analíticos para separação e quantificação de citrato de colina e acetilmetionina em formulações injetáveis por cromatografia líquida de alta eficiência (CLAE) e eletroforese capilar (EC). O método por CLAE, com o qual foi possível quantificar e separar simultaneamente, o citrato de colina e a acetilmetionina, foi realizado empregando-se uma coluna cromatográfica C18, 250 x 4,6 mm, 5µm, Shim-Pack® VP-ODS e fase móvel constituída por tampão fosfato de potássio 25 mM pH 5,7: acetonitrila: metanol (88:10:2 v/v/v). O método por EC foi validado utilizando-se como eletrólito, tampão de tetraborato de sódio 20 mM a pH 9,2 e capilar de sílica fundida de 40,2 cm, sendo 30 cm efetivos, com 75 µm de diâmetro interno. O método por CLAE apresentou um coeficiente de correlação (r) de 0,9996 para o citrato de colina e 0,9998 para a acetilmetionina. No método por EC, o coeficiente de correlação (r) encontrado foi de 0,9996 para a acetilmetionina. Os métodos podem ser considerados eficientes e confiáveis para serem empregados em análises de rotina de controle de qualidade de soluções injetáveis contendo a associação dos dois fármacos selecionados para o estudo. / The objective of this research was to develop, to validate and to compare two analytical methods for separation and quantification of choline citrate and acetylmethionine in injectable formulations by high performance liquid chromatography (HPLC) and capillary electrophoresis (CE). The HPLC method which enables the separation and simultaneous quantitative determination of choline citrate and acetylmethionine was performed using a C18, 250 x 4.6 mm, 5µm-Shim-Pack®VP-ODS column and a mobile phase constituted of buffer 25 mM potassium phosphate, pH 5.7: acetonitrile: methanol (88:10:2 v/v/v). The CE method was validated using a solution of 20 mM sodium tetraborate buffer pH 9.2 as the electrolyte and a fused silica capillary of 40.2 cm, with 30 cm effective, and 75 mm of diameter. The HPLC method showed a correlation coefficient (r) of 0.9996 for choline citrate and 0.9998 for acetylmethionine. For CE method the correlation coefficient (r) was found to be 0.9996 for acetylmethionine. The methods showed to be efficient and reliable methods, and can be used in routine analysis for quality control of injectable solutions containing the association of the two compounds selected to be studied in this research.
120

Desenvolvimento de métodos analíticos por cromatografia líquida de alta eficiência e eletroforese capilar para medicamentos anti-histamínicos / Development of analytical methods by high performance liquid chromatography and capillary electrophoresis for antihistamines drugs.

Cintia Maria Alves Mothé 02 October 2013 (has links)
Loratadina, desloratadina, rupatadina e ebastina são anti-histamínicos H1 de segunda geração, pertencentes ao grupo piperidínico, utilizados em casos clínicos de afecções alérgicas devido a sua ação sobre a histamina, que é o principal mediador da alergia e, também, pela sua ação anti-inflamatória ocorrida pelo bloqueio do fator de ativação plaquetária (PAF). Esses fármacos são denominados agonistas inversos dos receptores H1 não-sedativos. No presente estudo, foram desenvolvidos e validados métodos para a quantificação de loratadina, desloratadina, rupatadina e da ebastina em produtos farmacêuticos utilizando as técnicas de cromatografia líquida de alta eficiência (CLAE) e eletroforese capilar (CE). As análises por CLAE foram realizadas utilizando coluna LiChroCART® 100 RP- CN, 5 µm, (125 x 4 mm), fase móvel constituída MEOH:Tampão Fosfato de Sódio 20 mmol/L pH 3,0, (65:35 v/v), vazão de 1,0 mL/min; volume de injeção 20 µL, temperatura de 25°C ± 1ºC, detecção CLAE-UV λmáx: 254 nm. Paralelamente, foram desenvolvidos e validados métodos por CE, utilizando modo de separação por CZE com capilar de sílica fundida de 40,5 cm efetivos e 50 cm totais, 75 µm de diâmetro interno e 375 µm de diâmetro externo, eletrólito: ácido bórico 35 mmol/L, pH 2,5, tensão aplicada de 20 kV para, loratadina, desloratadina e rupatadina, e de 24 kV para ebastina, injeção hidrodinâmica de 0,5 psi por 3 segundos, temperatura de 25ºC ± 1ºC. Detecção CE-UV λmáx:205 nm. Os procedimentos foram validados, avaliando-se os parâmetros de especificidade, linearidade, precisão, exatidão, limite de detecção e quantificação e robustez, cujos resultados cumpriram os requisitos preconizados pela RE nº 899 da ANVISA. Os métodos propostos foram aplicados na análise de produtos farmacêuticos. Deste modo, os procedimentos estabelecidos podem ser aplicados para o aprimoramento do controle de qualidade de medicamentos, bem como garantir a segurança e a eficácia do uso terapêutico. / Loratadine, desloratadine, rupatadine and ebastine are second generation H1 antihistamines belonging to the group piperidine. They are often used in the clinical cases of allergic diseases due to their action on histamine, which is the main mediator of allergy and also by their anti-inflammatory action mediated through platelet activating factor (PAF) blocking activity. These drugs are called inverse agonists of non-sedating H1 receptor. In present study a high performance liquid chromatographic (HPLC) and capillary electrophoresis (CE) methods were developed and validated for quantitative determination of loratadine, desloratadine, ebastine rupatadine in pharmaceutical drug products. The HPLC method was developed using LiChroCART ® RP-100 CN 5 microns (125 x 4 mm) column, mobile phase composed of MeOH: sodium phosphate buffer 20 mmol/L, pH 3.0 (65:35 v/v ) at a flow rate 1.0 mL/min, injection volume 20µL. The temperature was maintained at 25 ± 1 °C and UV detection was made at 254 nm. In parallel, a CE method was developed and validated using CZE mode using a fused silica capillary of 40.5 cm effective length and 50 cm total length with inner and outer diameter of 75 µm and 375µm, respectively. The background electrolyte was composed of 35 mmol/L boric acid, pH 2.5, applied voltage of 20 kV for loratadine, desloratadine and rupatadine and 24 kV for ebastine, hydrodynamic injection at 0.5 psi for 3 seconds. All analyses were made at 25 ± 1 °C and UV detection was made at 205 nm. The CE method was validated and following parameters were evaluated; specificity, linearity, precision, accuracy, limit of detection and quantification and robustness. The results met the requirements recommended by RE No. 899 of ANVISA. The proposed methods were applied in the analysis of referred pharmaceuticals. Thus, the proposed methods can be applied to improve the quality control of pharmaceuticals and consequently ensure the safety and efficacy of these products in therapeutic use.

Page generated in 0.0652 seconds