• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 23
  • Tagged with
  • 23
  • 23
  • 23
  • 23
  • 23
  • 21
  • 12
  • 10
  • 10
  • 8
  • 7
  • 7
  • 7
  • 7
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Determinação quantitativa de gemifloxacino por cromatografia líquida de alta eficiência e eletroforese capilar / Quantitative determination of gemifloxacin mesylate in tablets by capillary zone electrophoresis and high performance liquid chromatography

Tavares, Vanessa Franco 25 August 2010 (has links)
Gemifloxacino (GMFLX) é um agente fluorquinôlonico, antibacteriano recentemente desenvolvido que apresenta um amplo espectro de atividade. O objetivo deste estudo foi desenvolver e validar métodos seletivos e sensíveis para a determinação quantitativa de GMFLX em comprimidos revestidos por cromatografia líquida de alta eficiência (CLAE) e eletroforese capilar de zona (CZE). O método por CLAE foi realizado em uma coluna LiChrospher&#174; 100 RP-8e, 5&#181;m (125 x 4 mm) e uma fase móvel composta por tetraidrofurano:água (25:75, v/v) com 0.5% de trietilamina e pH ajustado para 3.0 com ácido ortofosfórico. O tempo de retenção do GMFLX foi de 2.3 min. O método mostrou boa linearidade (r2 0.9989) e precisão (RSD% < 0.89). A exatidão foi expressa em percentagem de recuperação (R% &#8804; 101.3%). O método por CZE foi realizado utilizando 50 mmol L-1 de tampão tetraborato de sódio (pH 8.6). As amostras foram injetadas hidrodinâmicamente (0.5 psi, 5s) e o sistema eletroforético foi operado sob polaridade normal, em +20 kV e temperatura de 18 °C. O capilar utilizado foi de sílica fundida de 40.2 cm de comprimento (30 cm efetivos) x 75 &#181;m (d.i.) x 375 &#181;m (d.e.). Esse método apresentou um tempo de migração de 2.55 min para o GMFLX e 1.66 min para o metoprolol (padrão interno). Os parâmetros avaliados apresentaram linearidade (r2 0.9992), precisão (RSD% < 4.2) e exatidão (R% &#8804; 101.8%). Tanto a CLAE quanto a CZE foram consideradas técnicas interessantes e eficientes para serem aplicadas no controle de qualidade em indústrias farmacêuticas. / Gemifloxacin (GMFLX) is a recently developed fluorquinolone antibacterial agent presenting a broad spectrum of activity. The aim of this study was to develop and validate selective and sensitive methods for quantitative determination of GMFLX in coated tablets by high performance liquid chromatography (HPLC) and capillary zone electrophoresis (CZE). The HPLC method was carried out on a LiChrospher&#174; 100 RP-8e, 5&#181;m (125 x 4 mm) column with a mobile phase composed of tetrahydrofuran-water (25:75, v/v) with 0.5% of triethylamine and pH adjusted to 3.0 with orthophosphoric acid. The retention time of GMFLX was 2.3 min. The method showed good linearity (r2 0.9989) with good precision (RSD < 0.89%). Accuracy was expressed as percentage recovery (R% &#8804; 101.3%). The CZE method was performed using 50 mmoL-1 sodium tetraborate buffer (pH 8.6). Samples were injected hydrodynamicaly (0.5 psi, 5s) and the electrophoretic system was operated under normal polarity, at +20kV and temperature of 18°C. A fused-silica capillary 40.2 cm (30 cm effective length) x 75 &#181;m (i.d.) x 375 &#181;m (o.d.) was used. This method presented a migration time of 2.55 min for GMFLX and 1.66 min for metoprolol (internal standard). The evaluated parameters presented acceptable linearity (r2 0.9992), precision (RSD < 4.2%) and accuracy (R% &#8804; 101.8%). Both, HPLC and CZE method could be interesting and efficient techniques to be applied for quality control in pharmaceutical industries.
12

Validação de métodos para análise de estatinas em medicamentos por cromatografia líquida de alta eficiência e eletroforese capilar / Validation of methods for analysis of statins in pharmaceutical preparations by high performance liquid chromatography and capillary electrophoresis

González Tejerina, Karina Litzi 05 December 2011 (has links)
As estatinas são os fármacos mais usados para tratamento das hiperlipidemias em prevenção primária e secundária, com o propósito de diminuir os níveis de lipoproteínas plasmáticas ricas em colesterol e reduzir os riscos de doença arterialcoronária (DAC) (WITZTUM, 2005). Estes efeitos são resultantes da atividade inibidora das estatinas sobre a enzima HMG-CoA redutase (hidroximetilglutaril-CoA redutase), com a propriedade de bloquear a conversão do substrato HMG-CoA em ácido mevalônico, inibindo os primeiros passos da biossíntese de colesterol. Estas substâncias, (fluvastatina FS, atorvastatina ATC e rosuvastatina RC) são capazes de mimetizar o substrato natural. Podem ser divididas em naturais e sintéticas e diferem fundamentalmente, em termos de potência, perfil farmacocinético, interação farmacológica e efeito indesejado relacionado à miotoxicidade. Na presente pesquisa foram desenvolvidos e validados métodos analíticos de separação (cromatografia liquida de alta eficiência e eletroforese capilar) para cada fármaco. Estes métodos foram aplicados a medicamentos comercializados no Brasil. O método por CLAE foi realizado em coluna LiChrospher® RP-18 (125x4 mm, 5&#181;m) Merck® e uma fase móvel composta por metanol:água (70:30 v/v) para FS e ATC, (60:40 v/v) para RC, com 5 mM trietilamina e pH ajustado para 3.0 com ácido ortofosfórico. O método mostrou boa linearidade (r 0,9915), (LD 2,02 e LQ 6,12) FS; (r 0,9959), (LD 0,44 e LQ 1,34) ATC e (r 0,9945), (LD 1,55 e LQ 4,70) RC. A exatidão foi expressa em porcentagem de recuperação (R% 99,59) FS, (R% 100,24) ATC e (R% 99,2). Pelo método MEKC foi realizado utilizando capilar de sílica fundida de 40,2 cm x 75 m d. i. (30 cm até detector); eletrólito: tampão borato 20 mM: SDS 30 mM: metanol10% v/v pH 9,24; voltagem aplicada: +22 kV; injeção: hidrodinâmica 0,5 psi/3s, apresentaram linearidade (r 0,9997), (LD 0,94 e LQ 2,85) FS; (r 0,9999), (LD 2,36 e LQ 7,17) ATC. A porcentagem de recuperação (R% 104,61) FS, (R% 103,96) ATC. Pelo método CZE foi realizado utilizando sílica fundida de 40,2 cm de cumprimento sendo 30 cm até o detector, 75 &#181;m de d.i. e 375 &#181;m de d.d., eletrólito: tampão tetraborato de sódio 20 mM, pH 9,20; voltagem aplicada: +25kV; injeção: hidrodinâmica 0,5 psi/5s, apresentou linearidade (r 0,9989), (LD 4,92 e LQ 14,91) RC; A porcentagem de recuperação (R% 100,66) RC. / Statins are the drugs most commonly used for treatment of hyperlipidemia in primary and secondary prevention, with the aim of reducing levels of lipoproteins rich in cholesterol and reduce the risk of coronary-artery disease (CAD) (Witztum, 2005). These effects are due to the inhibitory activity of statins on the enzyme HMG-CoA reductase (hydroxymethylglutaryl CoA reductase), with the property to block the conversion of the substrate HMG-CoA to mevalonic acid, inhibiting the first steps of cholesterol biosynthesis. These substances (fluvastatin FS, atorvastatin ATC and rosuvastatin RC) may mimic the natural substrate, can be divided into natural and synthetic, and differ fundamentally in terms of potency, pharmacokinetics, drug interactions and unwanted effects related to muscle-toxicity. In the present study were developed and fully validated analytical methods of separation (high efficiency liquid chromatography and capillary electrophoresis) for each drug. These methods were applied to drugs marketed in Brazil. The method was performed by HPLC column LiChrospher® RP-18 (125x4 mm, 5mm) Merck® and a mobile phase consisting of methanol: water (70:30 v / v) for FS and ATC (60:40 v / v) to RC, with 5 mM triethylamine and pH adjusted to 3.0 with orthophosphoric acid. The method showed good linearity (r 0.9915), (2.02 LD and LQ 6.12) FS; (r 0.9959), (0.44 LD and LQ 1.34) ATC; (r 0.9945), (1.55 LD and LQ 4.70) for RC. The accuracy was expressed as a percentage of recovery (R% 99.59%) FS, (R% 100.24) ATC and (R 99.2%) RC. The MEKC method was performed using a fused silica capillary of 40.2 cm x 75 m d. i. (30 cm to detector); electrolyte: 20 mM borate buffer: 30 mM SDS: metanol10% v / v pH 9.24, applied voltage: +22 kV, injection: hydrodynamic psi/3s 0.5 showed linearity (r 0, 9997), (LQ 0.94 and LD 2.85) FS, (r 0.9999), (LQ 2.36 and LD 7.17) ATC. The percentage recovery (% R 104.61) FS, (R 103.96%) ATC. The CZE method was performed using fused silica of 40.2 cm long and 30 cm to the detector, 75 mm in di and 375 mm in dd, electrolyte: sodium tetraborate buffer 20 mM, pH 9.20, applied voltage: +25 kV, injection: hydrodynamic psi/5s 0.5, showed linearity (r 0.9989), (4.92 LD and LQ 14.91) RC; The percentage recovery (% R 100.66) RC.
13

Determinação quantitativa de gemifloxacino por cromatografia líquida de alta eficiência e eletroforese capilar / Quantitative determination of gemifloxacin mesylate in tablets by capillary zone electrophoresis and high performance liquid chromatography

Vanessa Franco Tavares 25 August 2010 (has links)
Gemifloxacino (GMFLX) é um agente fluorquinôlonico, antibacteriano recentemente desenvolvido que apresenta um amplo espectro de atividade. O objetivo deste estudo foi desenvolver e validar métodos seletivos e sensíveis para a determinação quantitativa de GMFLX em comprimidos revestidos por cromatografia líquida de alta eficiência (CLAE) e eletroforese capilar de zona (CZE). O método por CLAE foi realizado em uma coluna LiChrospher&#174; 100 RP-8e, 5&#181;m (125 x 4 mm) e uma fase móvel composta por tetraidrofurano:água (25:75, v/v) com 0.5% de trietilamina e pH ajustado para 3.0 com ácido ortofosfórico. O tempo de retenção do GMFLX foi de 2.3 min. O método mostrou boa linearidade (r2 0.9989) e precisão (RSD% < 0.89). A exatidão foi expressa em percentagem de recuperação (R% &#8804; 101.3%). O método por CZE foi realizado utilizando 50 mmol L-1 de tampão tetraborato de sódio (pH 8.6). As amostras foram injetadas hidrodinâmicamente (0.5 psi, 5s) e o sistema eletroforético foi operado sob polaridade normal, em +20 kV e temperatura de 18 °C. O capilar utilizado foi de sílica fundida de 40.2 cm de comprimento (30 cm efetivos) x 75 &#181;m (d.i.) x 375 &#181;m (d.e.). Esse método apresentou um tempo de migração de 2.55 min para o GMFLX e 1.66 min para o metoprolol (padrão interno). Os parâmetros avaliados apresentaram linearidade (r2 0.9992), precisão (RSD% < 4.2) e exatidão (R% &#8804; 101.8%). Tanto a CLAE quanto a CZE foram consideradas técnicas interessantes e eficientes para serem aplicadas no controle de qualidade em indústrias farmacêuticas. / Gemifloxacin (GMFLX) is a recently developed fluorquinolone antibacterial agent presenting a broad spectrum of activity. The aim of this study was to develop and validate selective and sensitive methods for quantitative determination of GMFLX in coated tablets by high performance liquid chromatography (HPLC) and capillary zone electrophoresis (CZE). The HPLC method was carried out on a LiChrospher&#174; 100 RP-8e, 5&#181;m (125 x 4 mm) column with a mobile phase composed of tetrahydrofuran-water (25:75, v/v) with 0.5% of triethylamine and pH adjusted to 3.0 with orthophosphoric acid. The retention time of GMFLX was 2.3 min. The method showed good linearity (r2 0.9989) with good precision (RSD < 0.89%). Accuracy was expressed as percentage recovery (R% &#8804; 101.3%). The CZE method was performed using 50 mmoL-1 sodium tetraborate buffer (pH 8.6). Samples were injected hydrodynamicaly (0.5 psi, 5s) and the electrophoretic system was operated under normal polarity, at +20kV and temperature of 18°C. A fused-silica capillary 40.2 cm (30 cm effective length) x 75 &#181;m (i.d.) x 375 &#181;m (o.d.) was used. This method presented a migration time of 2.55 min for GMFLX and 1.66 min for metoprolol (internal standard). The evaluated parameters presented acceptable linearity (r2 0.9992), precision (RSD < 4.2%) and accuracy (R% &#8804; 101.8%). Both, HPLC and CZE method could be interesting and efficient techniques to be applied for quality control in pharmaceutical industries.
14

Validação de métodos para análise de estatinas em medicamentos por cromatografia líquida de alta eficiência e eletroforese capilar / Validation of methods for analysis of statins in pharmaceutical preparations by high performance liquid chromatography and capillary electrophoresis

Karina Litzi González Tejerina 05 December 2011 (has links)
As estatinas são os fármacos mais usados para tratamento das hiperlipidemias em prevenção primária e secundária, com o propósito de diminuir os níveis de lipoproteínas plasmáticas ricas em colesterol e reduzir os riscos de doença arterialcoronária (DAC) (WITZTUM, 2005). Estes efeitos são resultantes da atividade inibidora das estatinas sobre a enzima HMG-CoA redutase (hidroximetilglutaril-CoA redutase), com a propriedade de bloquear a conversão do substrato HMG-CoA em ácido mevalônico, inibindo os primeiros passos da biossíntese de colesterol. Estas substâncias, (fluvastatina FS, atorvastatina ATC e rosuvastatina RC) são capazes de mimetizar o substrato natural. Podem ser divididas em naturais e sintéticas e diferem fundamentalmente, em termos de potência, perfil farmacocinético, interação farmacológica e efeito indesejado relacionado à miotoxicidade. Na presente pesquisa foram desenvolvidos e validados métodos analíticos de separação (cromatografia liquida de alta eficiência e eletroforese capilar) para cada fármaco. Estes métodos foram aplicados a medicamentos comercializados no Brasil. O método por CLAE foi realizado em coluna LiChrospher® RP-18 (125x4 mm, 5&#181;m) Merck® e uma fase móvel composta por metanol:água (70:30 v/v) para FS e ATC, (60:40 v/v) para RC, com 5 mM trietilamina e pH ajustado para 3.0 com ácido ortofosfórico. O método mostrou boa linearidade (r 0,9915), (LD 2,02 e LQ 6,12) FS; (r 0,9959), (LD 0,44 e LQ 1,34) ATC e (r 0,9945), (LD 1,55 e LQ 4,70) RC. A exatidão foi expressa em porcentagem de recuperação (R% 99,59) FS, (R% 100,24) ATC e (R% 99,2). Pelo método MEKC foi realizado utilizando capilar de sílica fundida de 40,2 cm x 75 m d. i. (30 cm até detector); eletrólito: tampão borato 20 mM: SDS 30 mM: metanol10% v/v pH 9,24; voltagem aplicada: +22 kV; injeção: hidrodinâmica 0,5 psi/3s, apresentaram linearidade (r 0,9997), (LD 0,94 e LQ 2,85) FS; (r 0,9999), (LD 2,36 e LQ 7,17) ATC. A porcentagem de recuperação (R% 104,61) FS, (R% 103,96) ATC. Pelo método CZE foi realizado utilizando sílica fundida de 40,2 cm de cumprimento sendo 30 cm até o detector, 75 &#181;m de d.i. e 375 &#181;m de d.d., eletrólito: tampão tetraborato de sódio 20 mM, pH 9,20; voltagem aplicada: +25kV; injeção: hidrodinâmica 0,5 psi/5s, apresentou linearidade (r 0,9989), (LD 4,92 e LQ 14,91) RC; A porcentagem de recuperação (R% 100,66) RC. / Statins are the drugs most commonly used for treatment of hyperlipidemia in primary and secondary prevention, with the aim of reducing levels of lipoproteins rich in cholesterol and reduce the risk of coronary-artery disease (CAD) (Witztum, 2005). These effects are due to the inhibitory activity of statins on the enzyme HMG-CoA reductase (hydroxymethylglutaryl CoA reductase), with the property to block the conversion of the substrate HMG-CoA to mevalonic acid, inhibiting the first steps of cholesterol biosynthesis. These substances (fluvastatin FS, atorvastatin ATC and rosuvastatin RC) may mimic the natural substrate, can be divided into natural and synthetic, and differ fundamentally in terms of potency, pharmacokinetics, drug interactions and unwanted effects related to muscle-toxicity. In the present study were developed and fully validated analytical methods of separation (high efficiency liquid chromatography and capillary electrophoresis) for each drug. These methods were applied to drugs marketed in Brazil. The method was performed by HPLC column LiChrospher® RP-18 (125x4 mm, 5mm) Merck® and a mobile phase consisting of methanol: water (70:30 v / v) for FS and ATC (60:40 v / v) to RC, with 5 mM triethylamine and pH adjusted to 3.0 with orthophosphoric acid. The method showed good linearity (r 0.9915), (2.02 LD and LQ 6.12) FS; (r 0.9959), (0.44 LD and LQ 1.34) ATC; (r 0.9945), (1.55 LD and LQ 4.70) for RC. The accuracy was expressed as a percentage of recovery (R% 99.59%) FS, (R% 100.24) ATC and (R 99.2%) RC. The MEKC method was performed using a fused silica capillary of 40.2 cm x 75 m d. i. (30 cm to detector); electrolyte: 20 mM borate buffer: 30 mM SDS: metanol10% v / v pH 9.24, applied voltage: +22 kV, injection: hydrodynamic psi/3s 0.5 showed linearity (r 0, 9997), (LQ 0.94 and LD 2.85) FS, (r 0.9999), (LQ 2.36 and LD 7.17) ATC. The percentage recovery (% R 104.61) FS, (R 103.96%) ATC. The CZE method was performed using fused silica of 40.2 cm long and 30 cm to the detector, 75 mm in di and 375 mm in dd, electrolyte: sodium tetraborate buffer 20 mM, pH 9.20, applied voltage: +25 kV, injection: hydrodynamic psi/5s 0.5, showed linearity (r 0.9989), (4.92 LD and LQ 14.91) RC; The percentage recovery (% R 100.66) RC.
15

Estratégias de microfabricação utilizando toner para produção de dispositivos microfluídicos / Strategies microfabrication using toner to produce microfluidic devices

Heron Dominguez Torres da Silva 04 September 2006 (has links)
Neste trabalho são apresentados processos de microfabricação de estruturas contendo microcanais e sistemas de manipulação hidrodinâmica e eletroosmótica de fluídos. Foram desenvolvidos processos de microfabricação utilizando toner sobre poliéster, toner sobre vidro, toner como resiste, além de métodos alternativos de perfuração de lâminas e selagem de microestruturas em vidro, desenvolvimento de microestruturas para eletroforese capilar e espectrometria de massas com ionização por eletronebulização. A caracterização dos materiais e processos permitiu uma ampla visão das potencialidades e alternativas dos processos de microfabricação, tendo sido demonstrado que os dispositivos produzidos em toner-poliéster são quimicamente resistentes às substâncias tipicamente utilizadas em eletroforese capilar. Neste trabalho, um detector condutométrico sem contato foi implementado em microestruturas de toner-poliéster e a separação eletroforética de alguns metais alcalinos é demonstrada. A microestrutura foi projetada no formato padrão em cruz, tendo o canal de separação 22 mm de comprimento, 12 &#181;m de profundidade e largura típica. A cela condutométrica foi construída sobre o canal de separação utilizando-se fita adesiva de cobre (1 mm de largura) como eletrodos. O sinal aplicado na cela foi de 530 kHz e 10 Vpp . A separação de K+, Na+ e Li+ na concentração de 100 &#181;mol L-1 foi efetuada em torno de 0,8 min, utilizando-se 1 kV como potencial de separação. Foram desenvolvidos microchips para análise por espectrometria de massas com introdução de amostra por eletronebulização, sendo determinado cluster do íon cloreto em concentração de 1 mmol L+. Também solução com 1 mmol/L de glucosamina em água/metanol 1: 1 (v/v), sob corrente de 100 nA gerou sinal estável e livre de descarga corona. Utilizando detecção amperométrica, obteve-se eletroferogramas mostrando a separação de iodeto (10 mmol L-1) e ascorbato (40 mmol L-1) em potencial de separação de 4,0 kV (800 V cm-1 potencial de detecção de 0,9 V (vs. Ag/AgCI), injeção com 1,0 kV/1°s, tampão borato de sódio 10 mmol L+ com CTAH 0,2 mmol L-1, pH 9,2. Obteve-se eficiência de 1,6.104 pratos/m e foi possível obter limites de detecção de 500 nmol L-1 (135 amol) e 1,8 &#181;mol L-1 (486 amol) para iodeto e ascorbato, respectivamente. O processo de fabricação utilizando toner como material estrutural para microchips em vidro foi bem estabelecido, assim como os modos de detecção fotométrico e condutométrico foram demonstrados. Foram obtidos eletroferogramas par detecção condutométrica sem contato de solução 200 &#181;mol L-1 de K+, Na+ e U+, em tampão histidina/ácido lático 30 mmol L-1 9:1 (v/v) água:metanol, injeção eletrocinética de 2,0 kV/5,0 s, potencial de separação de 1 kV, 530 kHz de frequência e tensão de 2,0 Vpp. Também foi implementado um sistema de detecção fotométrico para microchip operando em 660 nm, tendo sido utilizado para a detecção de azul de metileno 1,0 mmol L-1 em tampão de corrida de barato de sódio 20 mmol L-1 (pH 9,2), com o detector posicionado a 40 mm do ponto de injeção e com injeção eletrocinética a 2,0 kV por 12 s com picos bem resolvidos em menos de 1 min. / Microfabrication processes and devices for hydrodynamic and electroosmotic manipulation were developed based on toner-polyester, toner-glass and toner-as-resist techniques. Additionally, techniques to perforate glass slides and sealing of glass devices were introduced. Microdevices for capillary electrophoresis and electrospray for mass spectrometry were developed using these techniques. The characterization of the materiais and the processes demonstrated that the devices obtained by the toner-polyester process are compatible with the media used for capillary electrophoresis. The detection of alkaline ions with capillary electrophoresis with contactless conductivity detection was demonstrated. The typical cross shape microstructure was designed with a 22-mm long and 12-&#181;m deep separation channel. The conductivity cell was implemented with 1-mm wide adhesive copper stripes. The applied signal was 530kHz and 10Vpp . The separation of 100&#181;mo1L-1 K+, Na+, and Li+ was accomplished in 0.8 min under a voltage of 1 kV. Another toner-polyester microchip was developed to demonstrate its usefulness for electrospray/mass spectrometry. Solutions of 1 mmol L-1 potassium chloride and 1 mmol L-1 glucosamine in water/methanol 1:1 (v/v) were introduced with stable current of 100 nA without corona discharge. Capillary electrophoresis with amperometric detection was also demonstrated. The separation of iodide (10 mmol L-1) and ascorbate (40 mmol L-1) was carried out at 4.0 kV (800 V cm-1) with detection potential of 0.9 V (vs. Ag/AgCl), electrokinetic injection at 1.0 kV/10 s, running buffer of sodium borate 10 mmol L-1 with CTAH 0.2 mmol L-1 , pH 9.2. The efficiency was 1.6.104 plates/m and the limits of detection were 500 nmol L-1 (135 9mol) and 1.8 &#181;mol L-1 (486 amol) for iodide and ascorbate, respectively. The toner-glass process was proposed and conductivity and photometric detections were demonstrated for the devices generated by this new technique. The separation of 200 pmol L-1 K+, Na+, and Li+ was achieved in buffer histidine/lactic acid 30 mmol L-1 water/methanol 9: 1 (v/v), electrokinetic injection at 2.0 kV/5.0 s, separation potential of 1 kV, and contactless conductivity detection at 530 kHz and 2.0 Vpp. The photometric detection of methylene blue at 660 nm was carried out in sodium borate 20 mmol L-1 (pH 9.2).
16

Quantificação de ácidos orgânicos e ácidos graxos precursores de CLA em braquiárias por eletroforese capilar

Castro, Renata de Jesus Coelho 07 August 2015 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-01-15T17:27:17Z No. of bitstreams: 1 renatadejesuscoelhocastro.pdf: 4626733 bytes, checksum: 62bb62e16069cf7f8e81f59effe1bd20 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-01-25T17:42:17Z (GMT) No. of bitstreams: 1 renatadejesuscoelhocastro.pdf: 4626733 bytes, checksum: 62bb62e16069cf7f8e81f59effe1bd20 (MD5) / Made available in DSpace on 2016-01-25T17:42:17Z (GMT). No. of bitstreams: 1 renatadejesuscoelhocastro.pdf: 4626733 bytes, checksum: 62bb62e16069cf7f8e81f59effe1bd20 (MD5) Previous issue date: 2015-08-07 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / A produção de leite e carne de bovinos no Brasil está baseada na utilização de pastagens, por constituírem alimento de menor custo para o produtor. No Brasil, as pastagens são a principal fonte de alimentação do rebanho, sendo responsável por quase 90% da carne bovina e pela maior parte do leite produzido no país. Sendo assim, surge a importância de um monitoramento rigoroso para se obter uma forragem de qualidade, visto que, a dieta desses ruminantes está diretamente relacionada com a qualidade do leite. Nos últimos anos, tem-se dado o interesse de conhecer substâncias químicas presentes nas forragens que possam contribuir tanto para uma boa qualidade do leite, como por exemplo: o ácido linoléico (C18:2 cis-9 cis-12) e o ácido α-linolênico (C18:3 cis-9 cis-12 cis-15), que são ácidos graxos precursores do ácido linoléico conjugado (CLA) quanto para seleção de cultivares resistentes ao estresse causado pela presença das cigarrinhas das pastagens, como por exemplo: ácidos orgânicos (ácidos cítrico, málico, aspártico e succínico). O objetivo deste trabalho foi utilizar a técnica de Eletroforese Capilar de Zona (CZE) como uma ferramenta para auxiliar na seleção de materiais com uma maior concentração dos precursores do CLA e materiais mais resistentes à presença das cigarrinhas das pastagens. Para análise dos precursores de CLA, o eletrólito utilizado constituiu-se de 17% de metanol, 33% de ACN, 12 mmol L- 1 de tetraborato de sódio, 12 mmol L-1 de Brij e pH próximo de 9,5 e as condições de análise foram: injeção hidrodinâmica (25 mbar por 5 s), voltagem de + 26 kV, temperatura no interior do capilar de 27 ºC, detecção direta no UV em 200 nm, capilar de TSU com 75 μm d.i. e 34 cm de comprimento total. O método de eletroforese capilar de zona (CZE) se mostrou eficaz para análise dos precursores de CLA, em 4 minutos. Foi realizada a comparação do método proposto com o método oficial por cromatografia a gás (CG) em seis amostras de braquiárias, sendo que, os resultados não apresentaram diferenças significativas em um intervalo de confiança a 95 %. Para análises dos ácidos orgânicos, o eletrólito utilizado constituiu-se de 20 mmolL-1 de ácido ftálico, 15 mmolL-1 de TRIS e 0,8 mmolL-1 de CTAB. As condições de análise foram: injeção hidrodinâmica (0,3 psi por 2 s), voltagem de - 15 kV, temperatura no interior do capilar de 25 ºC, detecção direta no UV em 240 nm, capilar de TSP com 75 μm d.i. e 375 μm d.e., 50,2 cm de comprimento total e 40,0 cm de comprimento efetivo. O método CZE se mostrou eficaz para análises dos ácidos orgânicos (ácido cítrico, ácido málico, ácidos aspártico e ácido succinico) relacionados aos estresses das plantas, pois foi possível a identificação em menos de 5 minutos, possibilitando assim um grande número de análises em um curto tempo. / Bovine milk and meat production in Brazil is based on the use of pastures, as they are less food costing for the producers. In Brazil, pastures are the leading power supply of the herd, which are responsable for almost 90% of bovine meat and the biggest part of milk produced in the country. By this way, rises a rigorous monitoring to get quality forage, considering that the rumminant diet is related to the milk quality. Last years, it has arised the interest of knowing chemical substances present in the feed that could contribute to a good milk quality, such as: linoleic acid (C18: 2 cis-cis-9-12) and α- linolenic acid (C18: 3 cis-cis-9-cis-12 15), which are precursors of fatty acids conjugated linoleic acid (CLA); and to selection of cultivars resistent to stress caused by the sharpshooters pastures presence, such as the organic acids (citric, malic, succinic and aspartic acid). This paper aimed use the Capillary Zone Electrophoresis (CZE) technique as a tool to assist the selection of materials with a higher concentration of CLA precursors and more resistant materials to the presence of sharpshooters pastures. For analysis of CLA precursors, the electrolyte used consisted of 17% methanol, 33% ACN, 12 mmol L-1 sodium tetraborate, 12 mmol L-1 and Brij pH of 9.5, and analysis conditions were: hydrodynamic injection (25 mbar for 5 sec) + 26 kV voltage, 27 ° C temperature capillary within, direct UV detection at 200 nm, TSU capillary with 75 μm d.i and 34 cm length. The CZE method is effective for CLA precursors analysis, in 4 minutes. A comparing of the proposed method to the official one was made, by using gas chromatography (GC) at six samples brachiaria, and the results showed no significant differences at a confidence interval of 95%. For analysis of organic acids, the electrolyte used consisted of 20 mmol L-1 phthalic acid, 15 mmol L-1 TRIS and 0.8 mmol L-1 CTAB. The analysis conditions were: hydrodynamic injection (0.3 psi/3 seconds), - 15 kV voltage, 25 ° C temperature capillary within, UV direct detection at 240 nm, TSP capillary with 75 μm d.i. and 375 μm d.e., 50,2 cm lenght and 40.0 cm effective length. The CZE method is effective for organic acids (citric acid, malic acid, aspartic acid and succinic acid) analysis related to the plants, as it was possible its identification in less than 5 minutes, allowing a large number of analyzes in a short time.
17

Determinação de alfahidroxiácidos por eletroforese capilar e cromatografia líquida de alta eficiência em produtos cosméticos / Determination of alpha hydroxy acids by capillary electrophoresis and high performance liquid chromatography in cosmetic products

Dutra, Elizângela Abreu 28 April 2005 (has links)
Nos últimos anos vários produtos cosméticos contendo alfahidroxiácidos (AHAs) têm sido desenvolvidos e estão disponíveis no comércio, causando uma grande revolução em relação ao tratamento da pele fotoenvelhecida. Com o aumento da produção desses produtos, torna-se necessário o desenvolvimento e validação de novas metodologias analíticas para determinar os AHAs contidos em preparações cosméticas, tanto para o controle da qualidade do produto como para a segurança do consumidor. Nesta pesquisa os AHAs tartárico, glicólico, lático e mandélico foram analisados simultaneamente por eletroforese capilar (CE) e cromatografia líquida de alta eficiência (CLAE). Os métodos foram validados avaliando-se os parâmetros de linearidade, limite de quantificação, precisão e exatidão. A separação e determinação quantitativa por CE dos ácidos glicólico, tartárico e lático foram realizadas empregando-se um capilar de sílica fundida com comprimento total de 57 cm e 50 cm de comprimento até o detector, 75 &#181;m d.i.; eletrólito constituído de hidrogenoftalato de potássio 10 mmol.L-1, CTAB 0,5 mmol.L-1, pH 4,1; tensão aplicada de -20 kV com detecção UV indireta a 254 nm; temperatura de 35°C. A separação e determinação quantitativa dos ácidos glicólico, tartárico e lático por CLAE foram realizadas empregando-se coluna Sinergy Hydro RP-18 Phenomenex&#174;, fase móvel constituída de solução fosfato de amônio 15 mmol.L-1, tetrabutilamônio 3 mmol.L-1, pH 2,0, vazão 0,7 mL/min e detecção no UV 220 nm. Para determinação do ácido mandélico por CLAE, foi empregada coluna RP-18 Lichrospher&#174; Merck, fase móvel constituída de solução de fosfato de amônio 15 mmol.L-1 / acetonitrila (80/20, v/v) , pH 2,5, vazão 1,0 mL/min. Os métodos propostos apresentaram boa linearidade com coeficiente de correlação (r) > 0,9999, boa especificidade, repetibilidade aceitável com desvio padrão relativo (RSD) < 1% para determinação nas amostras comerciais e exatidão com percentual de recuperação entre 99 e 101%. Os métodos propostos podem ser aplicados para determinação e quantificação de AHAs contidos em produtos cosméticos em curto espaço de tempo. / In recent years many new cosmetic products containing alpha-hydroxy acids (AHAs) have been developed and are commercially available, causing a great revolution to the treatment of the photoaging. With the increase of the production of these products, there is a need of development and validation of analytical methods for quantitative determination of AHAs, both for quality control purposes and to avoid excessive concentrations that could cause consumers undesirable side-effects. In this research, AHAs like tartaric, glycolic, lactic and mandelic acids were analyzed simultaneously using capillary electrophoresis (CE) and high performance liquid chromatography (HPLC). The methods were validated evaluating the parameters of linearity, limit of quantitation, precision and accuracy. The separation and determination for tartaric, glycolic and lactic acids using CE involved an uncoated silica capillary with 75 &#181;m i.d. and total length of 57 cm, 50 cm to the detector, with a solution containing 10 mmol.L-1 potassium phthalate as the background electrolyte and 0.5 mmol.L-1 cetyltrimethylammonium bromide as the electroosmotic flow modifier, pH 4.1, the applied voltage was -20 kV with indirect detection at 254 nm, the operating temperature was 35°C. The separation and determination for tartaric, glycolic and lactic acids using HPLC involved an Sinergy Hydro RP-18 Phenomenex&#174; column, a mobile phase constituted of 15 mmol.L-1 ammonium dihydrogen phosphate and 3 mmol.L-1 tetrabutylammmonium bromide, pH 2.0, a flow-rate of 0.7 mL.min-1 and UV detection at 220 nm. For the determination of the mandelic acid using HPLC involved an LiChrospher&#174; 100 RP-18 Merck column, a mobile phase constituted of 15 mmol.L-1 ammonium dihydrogen phosphate / acetonitrila (80/20, v/v) pH 2.5, a flow-rate of 1.0 mL.min-1 and UV detection at 220 nm. The proposed methods presented good linearity with correlation coefficients more than 0.9999, good specificity, acceptable repeatability, with relative standard deviation (RSD) were less than 1% for commercial samples determination, and recoveries were between 99% and 101 %. The proposed methods can be readily applied to commercially available cosmetic product for quantitative analysis with speed.
18

Novos dispositivos de microextração e pré-concentração para eletroforese capilar utilizando membranas microporosas ou processos eletroquímicos e sua potencialidade na análise de aminas e metais / New devices to extraction and preconcentration with microporous membranes and electrochemical procedures prior to capillary electrophoresis: some applications to amines and metals analysis

Antunes Junior, Osmar 13 October 2008 (has links)
A eletroforese capilar (CE) é uma técnica de separação eficiente, que tem merecido grande atenção nas últimas duas décadas, e que oferece soluções analíticas alternativas ou complementares à cromatografia líquida num número crescente campos de aplicação, incluindo análises de fármacos, compostos biológicos e biogênicos, dentre outros. Entre as vantagens comparativas da técnica figuram separações mais rápidas com pequeno dispêndio de amostras, solução tampão (e solvente orgânico, se usado), baixo custo de operação e manutenção. Todavia, a exigüidade de amostra no capilar tem como reflexo, via de regra, limites de detecção menos favoráveis que os da HPLC, uma limitação significativa na análise de traços, suplantável por técnicas e procedimentos de extração/acumulação prévia dos analitos. Nesta tese concebeu-se e implementou-se a combinação inédita entre a CE e a préconcentração eletroquímica de metais. Novos dispositivos para extração líquido/gás/líquido mediada por membranas microporosas também foram propostos e aplicados à analise de aminas voláteis, sempre utilizando detector de condutância medida sem contato direto com a solução (C4D, contactless capacitively coupled conductivity detection). Primeiramente, sem recorrer à preconcentração, definiu-se condições de análise para 16 aminas (metilamina, dimetilamina, trimetilamina, propilamina, n-butilamina, s-butilamina, t-butilamina, hexilamina, DMAE, etanolamina, dietanolamina, trietanolamina, 1,3-diaminopropano, 1,4-diaminobutano, 1,5-diaminopentano e 1,6-diaminohexano) juntamente com íon amônio, e, para análise de 9 metais (TI++, Cd2+, Pb2+,Cr3+, Zn2+, Ag+, Cu2+, Co2+ e Ni2+). Um método completo para análise de dimetilaminoetanol em formulações cosméticas por CE-C4D foi desenvolvido e validado. Os estudos de extração e pré-concentração líquido/gás/líquido foram realizados utilizando filamento oco de Oxyphan preenchido com solução coletora. Foi construída cela para extração gasosa constituída de recipiente fechado no qual se introduz amostra com analitos voláteis, ou volatilizáveis pela adição de reagente e/ou aquecimento (pervaporação). A bobina coletora de filamento oco preenchido com solução coletora foi montada na parte interna da tampa da cela. Testes realizados com amostras de tecidos de peixe demonstraram o funcionamento do sistema, que poderá ser aperfeiçoado e aplicado, por exemplo, à análise de aminas biogênicas primárias de baixo peso molecular, indicadoras de decomposição de certos alimentos. Criou-se também extrator microvolumétrico em que o filamento de Oxyphan é montado concentricamente no interior de um capilar de sílica fundida, para realização de estudos de extração líquido/gás/líquido em fluxo. Um sistema em fluxo compreendendo válvulas e microbombas foi montado e colocado sob controle de um programa de computador (Labview), que, entre outras funções, controla o deslocamento da solução coletora exposta no filamento oco (13 &#181;L) até o ponto exato da interface em que se dá a injeção no capilar da CE. Pela primeira vez recorreu-se à acumulação eletroquímica (ECPC) de analitos num sistema FIA-CE-C4D - uma configuração baseada inteiramente na eletroquímica -, visando expandir os limites de detecção das determinações e eliminar interferência de matriz por troca de meio. Implementou-se a pré-concentração catódica seguida de redissolução anódica com uma célula eletroquímica especial, em que o capilar da eletroforese é posicionado junto ao eletrodo de trabalho, feito de ouro obtido a partir de CD\'s graváveis. Uma célula microfluídica ECPC-FIA-CE-C4D também foi construída. Tomando íons Cu2+ como sistema modelo, demonstrou-se o aumento do sinal referente aos íons cobre(lI) no eletroferograma para tempos crescentes de acumulação eletroquímica. Para a solução de alto teor salino contendo mistura dos íons Cd(II), Pb(II), Zn(lI) e Cu(II), comprovou-se a eliminação da interferência da matriz por troca de meio antes da redissolução anódica. Os testes iniciais indicam que os novos dispositivos e sistemas propostos nesta tese para uso em conjunto com a CE têm potencialidade para desencadear novas pesquisas, desenvolvimento de métodos e aplicações, sendo passíveis também de miniaturização e automação. / Capillary electrophoresis (CE) is an efficient separation technique that evolved rapidly in the last couple of decades, now offering complementary or alternative analytical solutions to liquid chromatography for an expanding number of application fields including drugs, biological and biogenic compounds. Some comparative advantages of CE are faster separation, very low consumption of buffer solutions and samples (and organic solvents, if any), lower maintenance and operational costs. However, the quantification of a few nanoliters of analyte in a capillary, as a rule, compromises the detection limits attainable by HPLC, a shortcomming in trace analysis, suplantable by extraction/preconcentration of the analytes from the sample. The combination of electrochemical preconcentration (ECPC) with CE is first proposed in this thesis and tested with metal ions. New devices for liquid/gas/liquid extraction based on microporous filaments filled with a collector solution were proposed and applied to the analysis of volatile amines, The detector of choice was the C4D (capacitively coupled contactless conductivity detection) and CE-C4D working conditions were defined for the separation and determination of: i) 16 amines (methylamine, dimethylamine, trimethylamine, propylamine, n-butylamine, s-butylamine, t-butylamine, hexilamine, ethanolamine, diethanolamine, triethanolamine, DMAE, 1,3-diaminopropane, 1,4- diaminobutane, 1,5-diaminopentane and 1,6-diaminohexane) plus ammonium, ii) nine metallic ions (Tl+, Cd2+, Pb2+, Cr3+ Zn2+, Ag+, Cu2+, Co2+ e Ni2+). A complete method of analysis for Dimethyl-amino-ethanol (DMAE) in cosmetic formulations was established and validated. Liquid/gas/liquid extraction studies were based on the use of a polypropylene microporous filment (Oxyphan® ) filled with the collection solution. A closed cell was devised in which an Oxyphan® coil is installed beneath the cap and volatilization of sample components can be promoted by heating (pervaporation) or addition of a reactant. The device was successfully tested with fish samples by the detection of primary low molecular weight biogenic amines, a procedure of special interest in fast checking of fish or other foods for decomposition. A microvolumetric version of the liquid/gas/liquid extractor was created with an Oxyphan® hollow fiber mounted concentrically inside a silica capillary. A flow system comprising the micropumps, solenoid valves and the microextrator was designed, automatically operated under software control (Labview). This FIA-CE system was tested by the extraction/enrichment of volatile amines in the collecting solution (13 &#181;L) followed by accurate displacement to the interface with the CE capillary by the micropumps. Pioneering work with ECPC-FIA-CE-C4D an all-electrochemical system was conducted in this thesis aiming expanded detection limits and matrix effect reduction. An electrochemical cell for the interface with FIA-CE system was built in acrylic using gold electrodes made from gold-sputtered CD-Rs. A microfluidic version of the cell interfaced with the CE capillary was also conceived. The full system was evaluated by using Cu2+ as a model specie; an increase in analytical signal was observed as a function of the cathodic deposition time before stripping. For a mixture of Cd2+, Cu2+, Zn2+ and Pb2+ in a high saline media, elimination of the matrix interference by medium exchange before stripping was demonstrated. Initial favorable evaluations show that the devices and systems proposed in 12 the thesis have the potential to engender further research of methods and applications as well as miniaturization and automation of procedures.
19

Desenvolvimento de métodos eletroforéticos e cromatográficos para a determinação de benzodiazepínicos como adulterantes em formulações fitoterápicas para emagrecimento / Development of electrophoretic and chromatography methods for the determination of benzodiazepines as adulterants in phytotherapic formulations

Lima, Ana Paula Soares de 03 July 2009 (has links)
The adulteration of phytotherapic formulations has been increasing considerably in the recent years in several countries, by the fact that there is not an established efficient monitoring for the control of the manipulation and commercialization of the so called natural medicines . As the possibility of adulteration is relatively wide in terms of compound classes, the need of analytical methods with good sensitivity and selectivity, which are able to identify and quantify simultaneously more than one pharmaceutical in the same phytotherapic formulation, is very important. Considering the well known effects of these adulterants and its use and abuse in the formulations for weigh loss, two separations methods were developed in this study to enable the study of benzodiazepines alprazolam, clonazepam, chlordiazepoxide, diazepam, flurazepam, lorazepam, medazepam and midazolam as possible adulterants in phytotherapic formulations. For the electrophoretic method the optimized conditions were: buffer phosphate 100 mM, 15% acetonitrile (pH 2,0) as an electrolyte; fused silica capillary coated with a 60 cm layer of polymida (9,5 cm to the detector window) with 75 Um of internal diameter, operating at 25 °C; 15 kV of applied voltage, UV detection at 200 nm and anodic hydrodynamic injection for 2 seconds with a pressure of 30 mbar. The chromatographic method was optimized as the following conditions: eluent acetonitrile: water 40:60 (v / v) (pH 4,0) at flow 0,5 mL/min, UV detection at 230 nm and injection of 20 μL. The adulteration in these phytotherapic formulations occurs usually with the use of only one pharmaceutical class: a benzodiazepine, a anorexic and a antidepressant. It is not expected to find in the same sample more than one benzodiazepine. Therefore, the eletroforetic and chromatography proposed methods do not have the objective to detect all of benzodiazepines together in a same sample, but rather to promote the individual identification of all in a sample. The RP-HPLC method was validated for the determination of these benzodiazepines and applied for the determination of the adulterants in phytotherapic formulations used in the treatment of obesity, which have been commercialized as natural medicines by Brazilian pharmacies. The recovery experiments promoted recoveries values higher than 84,25 % for all the analyzed adulterants. The developed methods introduced high sensitivity, analytical precision, low cost and rapid analysis, confirming the applicability of the methods as an alternative for the control and monitoring of abuse use of these pharmaceuticals in phytotherapic formulations passible of adulteration. / A adulteração de formulações fitoterápicas tem aumentado consideravelmente nos últimos anos em alguns países, pelo fato de que ainda não há uma fiscalização eficiente estabelecida para o controle da manipulação e comercialização dos chamados medicamentos naturais . Como a possibilidade de adulteração é relativamente ampla em termos de classes de compostos, surge assim, a necessidade de métodos analíticos de boa seletividade e sensibilidade, capazes de identificar e quantificar simultaneamente mais de um fármaco na mesma formulação fitoterápica. Sabendo-se dos efeitos indesejados que esses adulterantes podem causar, além da necessidade de alertar a sociedade sobre os perigos do uso e abuso desses adulterantes nas formulações para emagrecimento, desenvolveu-se neste trabalho dois métodos de separação, para possibilitar o estudo da presença dos benzodiazepínicos alprazolam, clonazepam, clordiazepóxido, diazepam, flurazepam, lorazepam, medazepam e midazolam como possíveis adulterantes em produtos fitoterápicos: eletroforese capilar de zona (CZE) e cromatografia líquida de alta eficiência por fase reversa (RP-HPLC). Para o método eletroforético as condições otimizadas foram: eletrólito de trabalho tampão fosfato 100 mM, 15% acetonitrila (pH 2,0); capilar de sílica fundida revestido de poliimida de 60 cm de comprimento (com 9,5 cm da janela do detector) com diâmetro interno de 75 Um, operando a 25°C; voltagem aplicada de 15 kV; detecção UV em 200 nm e injeção hidrodinâmica anódica durante 2 segundos com pressão de 30 mBar. O método cromatográfico foi otimizado na seguinte condição: eluente acetonitrila:água 40:60 (v/v) (pH 4,0) em fluxo 0,5 mL/min; detecção UV em 230 nm e injeção de 20 μL. As adulterações nestas formulações fitoterápicas ocorrem, geralmente, com o uso de somente uma classe de fármacos: um benzodiazepínico, um anorexígeno e um antidepressivo. Não se espera encontrar em uma mesma amostra mais de um benzodiazepínico, portanto, os métodos eletroforéticos e cromatográficos propostos não têm como objetivo detectar todos os benzodiazepínicos juntos em uma mesma amostra e sim, promover a identificação individual de todos em uma amostra. O método de RP-HPLC foi validado para a determinação desses benzodiazepínicos e empregado na análise de formulações fitoterápicas utilizadas no tratamento da obesidade, as quais são comercializadas como medicamentos naturais por farmácias de manipulação brasileiras. Os ensaios de recuperação realizados promoveram recuperações acima de 84,25 % para todas as espécies de adulterantes analisadas. Os métodos desenvolvidos apresentaram alta sensibilidade, precisão analítica, baixo custo e análises rápidas, comprovando a aplicabilidade dos mesmos como uma alternativa para o controle e fiscalização do uso abusivo destes fármacos presentes em formulações fitoterápicas passíveis de adulteração.
20

Novos dispositivos de microextração e pré-concentração para eletroforese capilar utilizando membranas microporosas ou processos eletroquímicos e sua potencialidade na análise de aminas e metais / New devices to extraction and preconcentration with microporous membranes and electrochemical procedures prior to capillary electrophoresis: some applications to amines and metals analysis

Osmar Antunes Junior 13 October 2008 (has links)
A eletroforese capilar (CE) é uma técnica de separação eficiente, que tem merecido grande atenção nas últimas duas décadas, e que oferece soluções analíticas alternativas ou complementares à cromatografia líquida num número crescente campos de aplicação, incluindo análises de fármacos, compostos biológicos e biogênicos, dentre outros. Entre as vantagens comparativas da técnica figuram separações mais rápidas com pequeno dispêndio de amostras, solução tampão (e solvente orgânico, se usado), baixo custo de operação e manutenção. Todavia, a exigüidade de amostra no capilar tem como reflexo, via de regra, limites de detecção menos favoráveis que os da HPLC, uma limitação significativa na análise de traços, suplantável por técnicas e procedimentos de extração/acumulação prévia dos analitos. Nesta tese concebeu-se e implementou-se a combinação inédita entre a CE e a préconcentração eletroquímica de metais. Novos dispositivos para extração líquido/gás/líquido mediada por membranas microporosas também foram propostos e aplicados à analise de aminas voláteis, sempre utilizando detector de condutância medida sem contato direto com a solução (C4D, contactless capacitively coupled conductivity detection). Primeiramente, sem recorrer à preconcentração, definiu-se condições de análise para 16 aminas (metilamina, dimetilamina, trimetilamina, propilamina, n-butilamina, s-butilamina, t-butilamina, hexilamina, DMAE, etanolamina, dietanolamina, trietanolamina, 1,3-diaminopropano, 1,4-diaminobutano, 1,5-diaminopentano e 1,6-diaminohexano) juntamente com íon amônio, e, para análise de 9 metais (TI++, Cd2+, Pb2+,Cr3+, Zn2+, Ag+, Cu2+, Co2+ e Ni2+). Um método completo para análise de dimetilaminoetanol em formulações cosméticas por CE-C4D foi desenvolvido e validado. Os estudos de extração e pré-concentração líquido/gás/líquido foram realizados utilizando filamento oco de Oxyphan preenchido com solução coletora. Foi construída cela para extração gasosa constituída de recipiente fechado no qual se introduz amostra com analitos voláteis, ou volatilizáveis pela adição de reagente e/ou aquecimento (pervaporação). A bobina coletora de filamento oco preenchido com solução coletora foi montada na parte interna da tampa da cela. Testes realizados com amostras de tecidos de peixe demonstraram o funcionamento do sistema, que poderá ser aperfeiçoado e aplicado, por exemplo, à análise de aminas biogênicas primárias de baixo peso molecular, indicadoras de decomposição de certos alimentos. Criou-se também extrator microvolumétrico em que o filamento de Oxyphan é montado concentricamente no interior de um capilar de sílica fundida, para realização de estudos de extração líquido/gás/líquido em fluxo. Um sistema em fluxo compreendendo válvulas e microbombas foi montado e colocado sob controle de um programa de computador (Labview), que, entre outras funções, controla o deslocamento da solução coletora exposta no filamento oco (13 &#181;L) até o ponto exato da interface em que se dá a injeção no capilar da CE. Pela primeira vez recorreu-se à acumulação eletroquímica (ECPC) de analitos num sistema FIA-CE-C4D - uma configuração baseada inteiramente na eletroquímica -, visando expandir os limites de detecção das determinações e eliminar interferência de matriz por troca de meio. Implementou-se a pré-concentração catódica seguida de redissolução anódica com uma célula eletroquímica especial, em que o capilar da eletroforese é posicionado junto ao eletrodo de trabalho, feito de ouro obtido a partir de CD\'s graváveis. Uma célula microfluídica ECPC-FIA-CE-C4D também foi construída. Tomando íons Cu2+ como sistema modelo, demonstrou-se o aumento do sinal referente aos íons cobre(lI) no eletroferograma para tempos crescentes de acumulação eletroquímica. Para a solução de alto teor salino contendo mistura dos íons Cd(II), Pb(II), Zn(lI) e Cu(II), comprovou-se a eliminação da interferência da matriz por troca de meio antes da redissolução anódica. Os testes iniciais indicam que os novos dispositivos e sistemas propostos nesta tese para uso em conjunto com a CE têm potencialidade para desencadear novas pesquisas, desenvolvimento de métodos e aplicações, sendo passíveis também de miniaturização e automação. / Capillary electrophoresis (CE) is an efficient separation technique that evolved rapidly in the last couple of decades, now offering complementary or alternative analytical solutions to liquid chromatography for an expanding number of application fields including drugs, biological and biogenic compounds. Some comparative advantages of CE are faster separation, very low consumption of buffer solutions and samples (and organic solvents, if any), lower maintenance and operational costs. However, the quantification of a few nanoliters of analyte in a capillary, as a rule, compromises the detection limits attainable by HPLC, a shortcomming in trace analysis, suplantable by extraction/preconcentration of the analytes from the sample. The combination of electrochemical preconcentration (ECPC) with CE is first proposed in this thesis and tested with metal ions. New devices for liquid/gas/liquid extraction based on microporous filaments filled with a collector solution were proposed and applied to the analysis of volatile amines, The detector of choice was the C4D (capacitively coupled contactless conductivity detection) and CE-C4D working conditions were defined for the separation and determination of: i) 16 amines (methylamine, dimethylamine, trimethylamine, propylamine, n-butylamine, s-butylamine, t-butylamine, hexilamine, ethanolamine, diethanolamine, triethanolamine, DMAE, 1,3-diaminopropane, 1,4- diaminobutane, 1,5-diaminopentane and 1,6-diaminohexane) plus ammonium, ii) nine metallic ions (Tl+, Cd2+, Pb2+, Cr3+ Zn2+, Ag+, Cu2+, Co2+ e Ni2+). A complete method of analysis for Dimethyl-amino-ethanol (DMAE) in cosmetic formulations was established and validated. Liquid/gas/liquid extraction studies were based on the use of a polypropylene microporous filment (Oxyphan® ) filled with the collection solution. A closed cell was devised in which an Oxyphan® coil is installed beneath the cap and volatilization of sample components can be promoted by heating (pervaporation) or addition of a reactant. The device was successfully tested with fish samples by the detection of primary low molecular weight biogenic amines, a procedure of special interest in fast checking of fish or other foods for decomposition. A microvolumetric version of the liquid/gas/liquid extractor was created with an Oxyphan® hollow fiber mounted concentrically inside a silica capillary. A flow system comprising the micropumps, solenoid valves and the microextrator was designed, automatically operated under software control (Labview). This FIA-CE system was tested by the extraction/enrichment of volatile amines in the collecting solution (13 &#181;L) followed by accurate displacement to the interface with the CE capillary by the micropumps. Pioneering work with ECPC-FIA-CE-C4D an all-electrochemical system was conducted in this thesis aiming expanded detection limits and matrix effect reduction. An electrochemical cell for the interface with FIA-CE system was built in acrylic using gold electrodes made from gold-sputtered CD-Rs. A microfluidic version of the cell interfaced with the CE capillary was also conceived. The full system was evaluated by using Cu2+ as a model specie; an increase in analytical signal was observed as a function of the cathodic deposition time before stripping. For a mixture of Cd2+, Cu2+, Zn2+ and Pb2+ in a high saline media, elimination of the matrix interference by medium exchange before stripping was demonstrated. Initial favorable evaluations show that the devices and systems proposed in 12 the thesis have the potential to engender further research of methods and applications as well as miniaturization and automation of procedures.

Page generated in 0.1114 seconds