A newly designed economizer to improve waste heat recovery: A case study in a pasteurized milk plant

Niamsuwan, S., Kittisupakorn, P., Mujtaba, Iqbal M. January 2013 (has links)
no / An economizer is normally employed to perform heat recovery from hot exhaust gases to cold fluid. In this work, a newly designed economizer is devised to achieve high heat recovery in a pasteurized milk plant. In the economizer, the hot exhaust gas is divided into two channels flowing up on the left and right sides. After that, it is moving down passing over aligned banks of tubes, which water is flowing inside, in a triple passes fashion. Moreover, three dimensional (3D) models with heat transfer including fluid dynamic have been developed, validated by actual plant data and used to evaluate the performance of the economizer. Simulation results indicate that the newly designed economizer can recover the heat loss of 38% and can achieve the cost saving of 13%.
112

Mobile-cloud assisted video summarization framework for efficient management of remote sensing data generated by wireless capsule sensors

Mehmood, Irfan, Sajjad, M., Baik, S.W. 18 July 2019 (has links)
Yes / Wireless capsule endoscopy (WCE) has great advantages over traditional endoscopy because it is portable and easy to use, especially in remote monitoring health-services. However, during the WCE process, the large amount of captured video data demands a significant deal of computation to analyze and retrieve informative video frames. In order to facilitate efficient WCE data collection and browsing task, we present a resource- and bandwidth-aware WCE video summarization framework that extracts the representative keyframes of the WCE video contents by removing redundant and non-informative frames. For redundancy elimination, we use Jeffrey-divergence between color histograms and inter-frame Boolean series-based correlation of color channels. To remove non-informative frames, multi-fractal texture features are extracted to assist the classification using an ensemble-based classifier. Owing to the limited WCE resources, it is impossible for the WCE system to perform computationally intensive video summarization tasks. To resolve computational challenges, mobile-cloud architecture is incorporated, which provides resizable computing capacities by adaptively offloading video summarization tasks between the client and the cloud server. The qualitative and quantitative results are encouraging and show that the proposed framework saves information transmission cost and bandwidth, as well as the valuable time of data analysts in browsing remote sensing data. / Supported by Basic Science Research Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Education (2013R1A1A2012904).
113

Improved mine cooling system performance through the control of auxiliary systems / W. Bornman

Bornman, Waldo January 2012 (has links)
Industrial and mining sectors are amongst the largest single energy consumers in South Africa, making them a primary focus for implementing energy saving initiatives. Refrigeration systems on mines are responsible for consuming up to25 % of the electrical energy consumption on a typical South African deep level mine. Ample opportunities to reduce the energy consumption of these systems exists, as many of the current systems rely on old technology and function under partial or inadequate control management. In compiling this thesis, various energy saving strategies on deep level mines were investigated. In specific, the effects of controlling and improving the cooling auxiliaries. Scenarios were investigated and simulated, where after an optimum solution was implemented. Implementations, such as the ones covered in this dissertation, form part of the IDM (Integrated Demand Management) energy efficiency incentive introduced by Eskom, where funding is made available based on actual power saving; ensuring that the projects will be financially viable to the clients. Reduced electrical energy consumption realised from the abovementioned projects were measured, captured and compared to the consumption before project implementation to determine the achieved savings. Savings of up to 30 % of the plant installed capacity were realised, providing average savings of up to 2.3 MW per day. / Thesis (MIng (Mechanical Engineering))--North-West University, Potchefstroom Campus, 2013
114

Improved mine cooling system performance through the control of auxiliary systems / W. Bornman

Bornman, Waldo January 2012 (has links)
Industrial and mining sectors are amongst the largest single energy consumers in South Africa, making them a primary focus for implementing energy saving initiatives. Refrigeration systems on mines are responsible for consuming up to25 % of the electrical energy consumption on a typical South African deep level mine. Ample opportunities to reduce the energy consumption of these systems exists, as many of the current systems rely on old technology and function under partial or inadequate control management. In compiling this thesis, various energy saving strategies on deep level mines were investigated. In specific, the effects of controlling and improving the cooling auxiliaries. Scenarios were investigated and simulated, where after an optimum solution was implemented. Implementations, such as the ones covered in this dissertation, form part of the IDM (Integrated Demand Management) energy efficiency incentive introduced by Eskom, where funding is made available based on actual power saving; ensuring that the projects will be financially viable to the clients. Reduced electrical energy consumption realised from the abovementioned projects were measured, captured and compared to the consumption before project implementation to determine the achieved savings. Savings of up to 30 % of the plant installed capacity were realised, providing average savings of up to 2.3 MW per day. / Thesis (MIng (Mechanical Engineering))--North-West University, Potchefstroom Campus, 2013
115

Zdravotně technické instalace s nízkou spotřebou vody a energie / Plumbing Systems with Low Water and Energy Consumption

Nikrmajer, Vojtěch January 2013 (has links)
The thesis deals with energy-saving plumbing systems. It is divided into three parts: task analysis, applications theme on the building and experiment. In the first part are described the possibilities of saving water and energy in the plumbing systems. The second part contains a comparison of some variants of saving solution water supply system and sanitary drainage system at the hotel. Part of the experiment investigates the water consumption for washing hands in addiction: the pressure in the water supply system and the type of mixing valves.
116

Energetické hodnocení obecní budovy / Energy assessment of building of municipality

Janíková, Hana January 2013 (has links)
The main objective of the master’s thesis is elaboration of energy audit within the theme of energy rating of buildings. Work consists of the beginning to the given theme including the actual legislative regulations. Another part is elaboration of the energy audit of building municipality with design and rating the measures of reduction of energy consumptions. In experimental part work deals with evaluation of building thermal envelope with use of thermograph measurement, also with quality of indoor environment within the use of building by measurement of concentration of CO2 and with heat and humidity balance.
117

Energeticky uvědomělá rekonstrukce rodinného domu / Energy-conscious renovation of family house

Bohutínský, Zdeněk January 2014 (has links)
The aim of the thesis is a design of the best energy measures for a family house. At first there is carried out an energy assessment of the building. According to results of that survey there are drawn up some variants of measures. Furthermore, based on energy assessment results there is elaborated a project for reconstruction of the heating.
118

Cellulose-Based Hydrogels for High-Performance Buildings and Atmospheric Water Harvesting

Noor Mohammad Mohammad (17548365) 04 December 2023 (has links)
<p dir="ltr">Smart windows, dynamically adjusting optical transmittance, face global adoption challenges due to climatic and economic variability. Aiming these issues, we synthesized a methyl cellulose (MC) salt system with high tunability for intrinsic optical transmittance (89.3%), which can be applied globally to various locations. Specifically, the MC window has superior heat shielding potential below transition temperatures while turning opaque at temperatures above the Lower Critical Solution Temperature (LCST), reducing the solar heat gain by 55%. Such optical tunability is attributable to the particle size change triggered by the temperature-induced reversible coil-to-globular transition. This leads to effective refractive index and scattering modulation, making them prospective solutions for light management systems, an application ahead of intelligent fenestration systems. MC-based windows demonstrated a 9°C temperature decrease compared to double-pane windows on sunny days and a 5°C increase during winters in field tests, while simulations predict an 11% energy savings.</p><p dir="ltr">Incorporating MC-based phase change materials in passive solar panels indicated optimized energy efficiency, offering a sustainable alternative. Real-time simulations validate practical applicability in large-scale solar panels. Furthermore, a temperature-responsive sorbent with a dark layer demonstrates an optimal optical and water uptake performance. Transitioning between radiative cooling and solar heating, the sorbent exhibits high water harvesting efficiency in lab and field tests. With an adjustable LCST at 38 ℃, the cellulose-based sorbent presents a potential solution for atmospheric water harvesting, combining optical switching and temperature responsiveness for sustainable water access. Furthermore, the ubiquitous availability of materials, low cost, and ease-of-manufacturing will provide technological equity and foster our ambition towards net-zero buildings and sustainable future.</p>
119

Energy performance regulations and methodologies of energy saving in office buildings in southern Europe

Tsave, A. January 2009 (has links)
The Directive 2002/91/EC of the European Parliament and Council on energy performance of buildings entered into force on 4th January 2003, setting the minimum requirements of energy performance. All Member States had to incorporate the requirements of the new directive in national legislation by January 2006 and build up relevant systems and measures to transpose and implement these requirements. The stage of Directive’s implementation in the countries of Southern Europe is reported because of the similar climatic conditions and the geographical location for a future enforcement in Greece, as the building code in Greece is still under development. As energy use in buildings accounts for about 40% of the final energy demand in the European Union, the application of building standards can achieve a reduction in electric energy consumption and therefore an increase in energy performance of buildings. A record of the electric energy consumption of office buildings in the four Prefectures of Crete is implemented aiming at a future energy saving, which may be obtained by either through increased efficiency or by reducing electric energy consumption.
120

Energy-saving behavior in industrial management ─A case study of an automobile producer in Central Europe

Scherling, Theresa Eva January 2017 (has links)
Industry is one of the major energy consumers resulting in negative environmental impacts in the world. In this context, industrial energy management becomes critically important when improving industrial energy savings. Emphasized is the careful energy treatment in the Sustainable Development Goals of the United Nations. The dominance of a technical approach in current research of industrial energy management suppresses significant potentials of human behavior for energy efficiency. Societal problems such as the energy efficiency gap and the rebound effect may be tackled by involving energysaving behavior in interventions. This thesis aims to explain characteristics of energy-saving behavior in the industrial settings of an automobile producer in Central Europe. The manufacturer utilizes an energy management program, named QUEST, which is facilitated by the external advisor HE Consulting s.r.o. Questions of particular interest are therefore related to perceived organizational readiness to engage in energy-saving behavior. Data gathering include a structured-questionnaire of perceptions on energy savings at the plants with managers of the automobile producer. Additionally, a semi-structured interview with the CEO of HE Consulting s.r.o. offers a more in-depth view on practical implications of energysaving behavior. As a base for data collection serves a psychological perspective of perceptional theories. Strongly related is that approach to the change management discipline. Results of the study show that, indeed, managers in the QUEST program tend to perceive organizational readiness on energy savings re latively more positive than managers outside the program. Resistance to change can be marginally observed in lower management levels. However, the managers emphasize a lack of time to engage in energy savings. Indicators of perceived organizational readiness on energy savings alone do not show the actual energy-saving behavior. This means that this thesis does not directly observe energy-saving behavior. Nevertheless, the impact of such indicators on the actual performed energy-saving behavior may be seen in combination with quantified energy savings. All findings can only be interpreted in the frame of this study.