• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 20
  • Tagged with
  • 22
  • 22
  • 22
  • 22
  • 14
  • 12
  • 12
  • 5
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Avaliação da esterilização a vapor do instrumental laparoscópico montado: abordagem laboratorial / Evaluation of steam sterilization of laparoscopic instruments assembled: laboratory approach

Tamara Carolina de Camargo 29 July 2013 (has links)
Esta pesquisa avaliou a segurança microbiológica da esterilização a vapor do instrumental laparoscópico reutilizável montado. Foram selecionados dois tipos de instrumental laparoscópico reutilizável: trocarte e pinça de dissecção de 5mm. Considerando a eficácia da limpeza como pré-requisito essencial para o processo de esterilização, a PRIMEIRA ETAPA da pesquisa, avaliou 66 instrumentos laparoscópicos, sendo 33 pinças e 33trocartes, submetidos a diferentes métodos de limpeza, avaliando como desfecho os resíduos orgânicos de proteína, hemoglobina e carboidrato, após contaminação intencional com sangue de placenta humana. Os métodos de limpeza testados foram: (1) limpeza manual com enxágue em água potável; (2) limpeza manual com enxágue em água potável, seguida de limpeza ultrassônica sem enxágue; (3) limpeza manual com enxágue em água potável, seguida de limpeza ultrassônica com enxágue em água potável e (4) limpeza manual com enxágue em água potável, seguida de limpeza ultrassônica com enxágue em água potável e último enxágue em água destilada esterilizada. Os experimentos foram acompanhados pelos grupos controle Positivo (sem limpeza) e Negativo, composto por instrumental laparoscópico novos sem contaminação intencional, avaliados após os procedimentos de limpeza (1) e (4). Para avaliação dos resíduos orgânicos, utilizou-se o kit Quantipro BCA para dosagem de proteínas, TMB One para hemoglobina, fenol 5% e ácido sulfúrico para carboidrato, todos com leitura por espectrofotometria. O grupo controle Positivo evidenciou níveis médios de 332µg/cm2 proteína, 30µg/cm2 carboidrato e 417µg/cm2 hemoglobina. Conforme esperado, o método de limpeza (4) apresentou desempenho superior quando comparado com o método (1), reduzindo 92% a mais de µg/proteína/pinça e 60% a mais de µg/carboidrato/pinça e por trocarte, embora esta superioridade não tenha sido observada de uma forma uniforme em todo o experimento. No grupo controle Negativo, os níveis máximos de proteína detectados foram 1,70µg/cm2 e de carboidrato de 1,07µg/cm2, não sendo detectada hemoglobina. A SEGUNDA ETAPA, avaliou a esterilização do instrumental laparoscópico reutilizável montado com contaminação desafio de três vezes 106 esporos Geobacillus stearothermophillus ATCC 7953, impregnados em suporte de papel filtro extraídos do indicador biológico comercialmente disponível para monitoramento da autoclavação. Os experimentos microbiológicos foram acompanhados dos grupos controle Positivo (suporte do indicador biológico não submetido à esterilização) e controle Negativo (instrumentos laparoscópicos esterilizados desmontados com contaminação desafio). Como grupo Experimental, foram analisados 370 instrumentos laparoscópicos esterilizados montados, sendo 185 pinças e 185 trocartes. Três suportes de papel impregnados com os esporos foram introduzidos no interior de cada instrumento laparoscópico, precedidos de limpeza tipo (4), embalados em papel grau cirúrgico e submetidos à esterilização a vapor saturado sob pressão (134oC por 5 minutos). Com técnica asséptica, cada suporte de papel foi inoculado em meio de cultura de Tryptic Soy Broth (TSB), incubado a 56oC por 21 dias. Não sendo observado crescimento, as amostras foram submetidas a um choque térmico a 80oC, por 20 minutos, para estimular a germinação, com reincubação por mais 72 horas. Não houve crescimento microbiano algum nas amostras do grupo Experimental. Os resultados dos grupos controles foram satisfatórios. O controle Positivo confirmou o desafio imposto aos experimentos e o controle Negativo apresentou resultados esperados de ausência de crescimento. Este estudo forneceu fortes evidências científicas para os Centros de Material e Esterilização sustentarem a segurança microbiológica da prática de esterilização do instrumental laparoscópico montado / This study evaluated the microbiological safety of steam sterilization, the reusable laparoscopic instrument assembled. We selected two types of reusable laparoscopic instrument: trocar and dissecting forceps 5mm. Considering the efficacy of cleaning as an essential prerequisite for the sterilization process, the FIRST STEP evaluated 66 laparoscopic instruments, 33 trocars and 33 dissecting forceps, subjected to different cleaning methods evaluating outcome as organic waste protein, hemoglobin and carbohydrate after intentional contamination with blood from human placenta. Cleaning methods were tested: (1) manual cleaning rinse with potable water, (2) manual cleaning with rinsing in clean water, then cleaning ultrasonic without rinsing, (3) manual cleaning with rinsing in clean water, then cleaning ultrasonic rinse with potable water and (4) manual cleaning rinse with potable water, followed by ultrasonic cleaning with potable water rinse and final rinse in sterile distilled water. The experiments were accompanied by positive control groups (without cleaning) and negative, composed of laparoscopic instruments again without intentional contamination, assessed after the cleaning procedures (1) and (4). For evaluation of organic waste is used Quantipro BCA kit for the determination of protein, TMB One to hemoglobin, 5% phenol and sulfuric acid of carbohydrate with any read by spectrophotometry. The positive control group showed average levels of 332µg/cm2 protein, carbohydrate 30µg/cm2 and 417µg/cm2 hemoglobin. As expected, the cleaning method (4) superior performance when compared with the method (1), reducing 92% more µg/protein/forceps and more than 60% µg/carbohydrate/forceps and trocar, although this superiority has not been observed in a uniform manner throughout the experiment. In the negative control group maximum levels of protein detected were 1.70 µg/cm2 and 1.07 µg/cm2carbohydrate was not detected hemoglobin. The SECOND STEP evaluated the sterilization of reusable laparoscopic instruments assembled with contamination challenge 3 times 10 Geobacillusstearothermophillus spores ATCC 7953, impregnated strips filter paper extracted from commercially available biological indicator for monitoring steam sterilization. The experiments were accompanied microbiological positive control groups (biological indicator spore strips non-sterile) and negative (laparoscopic instruments sterilized contamination disassembled challenge). As experimental group were analyzed 370 laparoscopic instruments sterilized assembled, 185 dissecting forceps and 185 trocars. Three spore strips of paper impregnated were introduced in laparoscopic instrument within each preceded by cleaning type (4), packed in surgical paper and subjected to saturated steam sterilization under pressure (134oC for 5 minutes). With aseptic technique, each paper spore strip was inoculated into culture medium Tryptic Soy Broth (TSB) and incubated at 56oC for 21 days. No growth was observed, they were subjected to heat shock at 80oC for 20 minutes to stimulate germination, with more reincubation for 72 hours. There was no microbial growth in some samples of the experimental group. The results of the control groups were satisfactory. The Positive Control confirmed the challenge posed to experiments and the negative control presented results expected from the absence of growth. This study provides strong scientific evidence for the Centers for Material and Sterilization sustain the microbiological safety of the practice of sterilization of laparoscopic instruments assembled.
22

Adaptação cultural para o Brasil e desempenho psicométrico do instrumento "Evidence-Based Practice Quesntionnaire" (EBPQ) / Cultural adaptation for Brazil and the psychometric performance of the instrument "Evidence-Based Practice Questionnaire" (EBPQ)

Rospendowiski, Karina, 1987- 24 August 2018 (has links)
Orientador: Neusa Maria Costa Alexandre / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Enfermagem / Made available in DSpace on 2018-08-24T10:49:29Z (GMT). No. of bitstreams: 1 Rospendowiski_Karina_M.pdf: 1729835 bytes, checksum: f1388fbb6295fbb3e521138374665f49 (MD5) Previous issue date: 2014 / Resumo: INTRODUÇÃO: A Prática Baseada em Evidência compreende "o uso consciente, explícito e judicioso da melhor evidência atual para a tomada de decisão sobre o cuidar individual do paciente". Para a implantação da prática de enfermagem baseada em evidências, compete ao enfermeiro a busca de estratégias que permitam a utilização de pesquisa na prática. O instrumento "Evidence-based practice questionnaire" (EBPQ), avalia atitudes, conhecimento e implantação da Prática Baseada em Evidências. Utiliza Escala de Likert com pontuação de um a sete em três domínios: prática, atitudes e conhecimentos relacionados à Prática Baseada em Evidências. Mostrou-se uma ferramenta útil para mensurar a implantação desta prática com enfermeiros no Reino Unido e na Espanha. OBJETIVO: O presente estudo tem como objetivo adaptar culturalmente o instrumento EBPQ para a língua portuguesa do Brasil e avaliar suas qualidades psicométricas. METODOLOGIA: Estudo metodológico em que fizeram parte professores e alunos de uma Universidade Pública e enfermeiros de um Hospital Público. Foram seguidos os passos essenciais de adaptação cultural de instrumentos de medida: tradução do instrumento para a língua portuguesa, síntese, retro-tradução, avaliação pelo comitê de juízes e pré-teste. Foi verificada a confiabilidade por meio da avaliação da consistência interna e da estabilidade pelo teste-reteste e a validade de constructo com abordagem de grupos conhecidos, do qual fizeram parte enfermeiros com pós-graduação em Mestrado ou Doutorado e enfermeiros com graduação completa. RESULTADOS: As etapas de tradução, síntese e retro-tradução foram realizadas satisfatoriamente. A avaliação pelo comitê de juízes resultou em alterações em alguns itens, assegurando as equivalências entre as versões original e traduzida. Durante o pré-teste, foi verificada a compreensão dos itens para torná-los mais claros. Na avaliação das propriedades psicométricas, a versão brasileira do instrumento mostrou-se confiável, com Coeficiente Alfa de Cronbach satisfatório em todos os domínios (0,91 ¿ 0,68). O Coeficiente de Correlação Intraclasse, que avaliou a estabilidade do instrumento mostrou-se satisfatório para o instrumento como um todo (0,90). Na avaliação da validade de constructo, o instrumento foi capaz de demonstrar diferenças nos escores entre os grupos conhecidos, com pontuações mais elevadas no grupo de enfermeiros com Mestrado ou Doutorado. CONCLUSÃO: As etapas necessárias para a adaptação cultural de instrumentos de medida foram concluídas com sucesso. A versão brasileira obtida apresenta propriedades psicométricas confiáveis para a sua utilização nessa população / Abstract: INTRODUCTION: The Evidence-Based Practice comprehends "the conscious, explicit and judicious use of current best evidence for decision making about the individual caring of patients". To implement the evidence-based practice of nursing, the nurse is responsible for searching strategies that allow the use of research in practice. The instrument "Evidence-based practice questionnaire" (EBPQ) assesses attitudes toward, knowledge of and use of evidence-based practice. It uses Likert Scale which is a seven point scale used in three areas: practice, attitudes and knowledge related to Evidence Based Practice. It was proved to be a useful tool to measure the implementation of this practice with nurses in the United Kingdom and Spain. OBJECTIVE: This study aims to adapt culturally the tool EBPQ to the Portuguese Language and to evaluate its psychometric qualities. METHODOLOGY: For this methodological study, the participants were some teachers and students of a Public University and some nurses of a Public Hospital. The essential steps of cultural adaptation of measurement instruments were followed: instrument translation into Portuguese language, synthesis, retro-translation, evaluation by the committee of judges and pretest .The reliability was checked by means of evaluation of internal consistency and the stability by test-retest and the construct validity with known groups approach. The first group was formed by nurses with Masters' degree or PhD and the second group was formed by nurses with bachelor's degree. RESULTS: The steps of translation, retro-translation and synthesis were performed satisfactorily. The evaluation by the expert panel resulted in changes in some items, ensuring the equivalence between the original and translated versions .During the pretest, the understanding of the items was done in order to make them clearer. The Brazilian version was reliable , with satisfactory results , and it was obtained Cronbach's alpha similar to International studies for all domains ( .91 to .68 ) .The intraclass correlation coefficient , which evaluated the stability was satisfactory for the instrument as a whole ( 0,90 ) .In the assessment of construct validity , there was significant difference between groups in relation to evidence-based practice , with higher scores in the group of nurses with master's or PhD. CONCLUSION: The necessary steps for the cultural adaptation of the measurement instruments were finished successfully. The Brazilian version obtained presents reliable psychometric properties for its use in this population / Mestrado / Enfermagem e Trabalho / Mestra em Ciências da Saúde

Page generated in 0.0953 seconds