• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 198
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 199
  • 199
  • 69
  • 58
  • 56
  • 56
  • 52
  • 48
  • 37
  • 35
  • 35
  • 33
  • 31
  • 26
  • 24
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
171

Viabilidade do aproveitamento de resíduo de estação de tratamento de água (ETA) na confecção de concretos / Viability of the water treatment plant waste (WTP) utilization at concrete production

Ramirez, Kleber Gomes 04 September 2015 (has links)
O presente estudo objetiva avaliar a influência da substituição de areia natural por diferentes teores de Lodo de Estação de Tratamento de Água (Lodo de ETA) na produção de concretos ambientalmente amigáveis. O procedimento experimental abrangeu a coleta e caracterização das matérias-primas, o estudo de dosagem do concreto produzido com diferentes teores de substituição de Lodo Úmido (LU) e Lodo Calcinado (LC) e a avaliação das misturas produzidas no aspecto técnico, econômico e ambiental. As amostras de Lodo utilizadas foram coletadas na ETA Tamanduá, localizada em Foz do Iguaçu, PR, em três períodos distintos durante o ano de 2014. No estudo de dosagem fez-se a substituição de LU (in natura) por areia natural nos teores de 0, 5, 7 e 10% em concretos de relação água/cimento (a/c) 0,45, 0,55 e 0,65 e de LC (temperatura de 900 ºC) nos teores de 0, 5, 10 e 20% em misturas de a/c 0,55, avaliando-se as propriedades no estado fresco (trabalhabilidade) e no estado endurecido (resistência à compressão axial, resistência à tração, módulo de elasticidade, absorção de água e lixiviação). A partir dos resultados obtidos constatou-se que a adição de até 20% de LC propiciou aumento nas propriedades mecânicas do concreto, podendo ser empregado em concretos estruturais, desde que realizados estudos de durabilidade. Já a adição de lodo de ETA úmido reduziu significativamente a resistência do concreto, sendo indicado do ponto de vista técnico um teor de substituição de até 5% para aplicações em concretos, desde que não estruturais. Do ponto de vista econômico, em relação ao concreto de referência, concretos produzidos com LU resultaram em menor custo de produção enquanto que concretos com LC maior. Pela análise termogravimétrica o lodo poderá ser calcinado a menores temperaturas (de 300 a 500 oC), promovendo economia energética no processo de tratamento térmico, resultando num melhoramento no aspecto econômico e ambiental da aplicação do Lodo calcinado na produção de concretos. Por meio da viabilidade ambiental, os resultados demonstraram que os níveis de concentração das substâncias analisadas no ensaio de lixiviação atendem ao limite máximo permitido, assegurando a saúde humana e ambiental. A sustentabilidade do aproveitamento do lodo em concreto confirma-se pela redução na extração de recursos naturais, contribuindo principalmente, na diminuição do lançamento de lodo em corpos hídricos, e ao atendimento dos requisitos do sistema de gestão e legislação ambiental vigente. por teores mais elevados de lodo, analisando a viabilidade econômica e ambiental vinculada ao processo de calcinação. / The aim of this study is to evaluate the influence of replacing natural sand by different levels of Water Treatment Plant Sludge (WTP sludge) in the production of environmentally friendly concrete. The experiment included the collection and characterization of raw materials, the concrete dosing study produced with different sludge replacement levels of Wet Sludge (WS) and Calcined Sludge (CS) and the evaluation of the produced mixtures with regards the technical, economic and environmental aspect. The sludge samples used in the study were collected from the Tamandua ETA, located in Foz do Iguaçu, Paraná, in three different periods during the year 2014. In the dosage of study, WS (in natura) was substituted by natural sand in the levels of 0, 5, 7 and 10% in concrete with water/cement ratio (w/c) of 0.45, 0.55 and 0.65 and CS (temperature of 900 °C) in levels of 0, 5, 10 and 20% in mixtures with w/c of 0.55, evaluating the properties in the fresh state (workability) and in the hardened state (resistance to axial compression, tensile strength, elastic modulus, water absorption and leaching). From the results obtained it was found that the addition of CS up to 20% resulted in an increase in the mechanical properties of concrete, therefore it can be used in structural concrete, provided that durability studies are carried out. With regards WS, its addition significantly reduces the strength of concrete and is suitable, from a technical point of view, a replacement level up to 5% for applications in concrete, provided that not structural. From an economic point of view, in comparison to the reference concrete, concrete produced with WS resulted in lower production cost while concrete with CS the cost was higher. By thermogravimetric analysis, the sludge may be calcined at lower temperatures (300 to 500 °C), leading to energy saving in the heat treatment process, resulting in an improvement in the economic and environmental factor in the application of the calcinated sludge in the production of concrete. With regards the environmental viability, the results demonstrated that the levels of concentration of the substances analyzed in the leaching test meet the maximum allowed limit, ensuring environmental and human health. The sustainability of sludge use in concrete is confirmed by the reduction in the extraction of natural resources, contributing mainly to the decreas of sludge release in water bodies, and upon satisfying the requirements of the management and environmental legislation system. Further studies should be conducted to assess the effect of replacing sand for higher levels of sludge, analyzing the economic and environmental viability linked to the calcination process.
172

Síntese de nanowiskers de fibra de mandioca: formação de nanocompósitos com álcool polivinílico / Synthesis of cassava fiber nanowiskers: formation of nanocomposites with polyvinyl alcohol

Schoeler, Marcilene Neumann 10 August 2016 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação Araucária de Apoio ao Desenvolvimento Científico e Tecnológico do Paraná / Os nanowhiskers são domínios cristalinos de fontes celulósicas e têm sido usados na preparação de nanocompósitos devido à abundância de matéria-prima disponível oriundas de várias fontes renováveis e biodegradáveis. Além disso, apresentam facilidade de modificação de superfície por meio de tratamentos químicos, possuem grande área superficial e morfologia diferenciada, apresentando ótimas características mecânicas, térmicas e de barreira. Neste trabalho foram extraídos nanowhiskers de celulose do bagaço da raiz de mandioca gerado na etapa de separação da fécula. Os nanowhiskers de celulose obtidos por hidrólise ácida foram caracterizados por análises térmicas (TG e DSC), espectroscopia no infravermelho (FTIR) e difração de raios X (DRX). Nos espectros de FTIR foram observadas diferenças entre nanowhiskers (NWM), fibra bruta de mandioca (FBM) e fibra purificada de mandioca (FPM), indicando favorecimento na formação de nanowhiskers estáveis. A cristalinidade da FPM e dos NWM também foi observada no DRX, com o aumento de cristalinidade de 254,87 % e 165,62 %, respectivamente quando comparada com a FBM. A estabilidade térmica aumentou com os tratamentos químicos realizados na FBM e a degradação de NWM ocorrida basicamente em uma única etapa, indica homogeneidade química e dimensional da amostra. Nanocompósitos formados por matriz polimérica de álcool polivinílico (PVA) e reforços de 2,5, 5 e 10 % de NWM foram comparados com o PVA através de análises térmicas (TG e DSC), espectroscopia no infravermelho (FTIR), difração de raios X (DRX) e análise de tração. A estabilidade térmica aumentou do nanocompósito com reforço de 5 % de NWM. Na análise de FTIR, as bandas identificadas são características do PVA. O difratograma do DRX apresentou aumento de cristalinidade do nanocompósito com menor reforço de NWM, numa faixa de aumento de 38 %. As propriedades mecânicas apresentaram melhorias significativas nos nanocompósitos com reforço de NWM. O nanocompósito formado com menor quantidade de reforço, apresentou maior módulo de elasticidade e o nanocompósito formado com reforço de 5 % de NWW apresentou maior limite de resitência e ruptura de tensão. O presente trabalho constatou que a utilização da massa residual de fecularias torna-se de utilização promissora na produção de nanowhiskers e incorporação dos mesmos em nanocompósitos como reforço. / The nanowhiskers are crystalline domains of cellulosic sources and have been used in the preparation of nanocomposites due to the abundance of available raw material derived from several renewable and biodegradable sources. In addition, they show modification feature facility of surface by means of chemical treatments, and also have large superficial area and differentiated morphology, showing excellent mechanical and thermal characteristics, as well as of barrier. In this study nanowhiskers were extracted from cassava bagasse generated in starch separation step. The cellulose nanowhiskers obtained by acid hydrolysis were characterized by thermal analysis (TG and DSC), infrared spectroscopy (FTIR) and x-ray diffraction (DRX). In the FTIR spectra differences were observed between nonowhiskers (NWM), crude cassava fiber (FBM) and purified cassava fiber (FPM), indicating favoring in the formation of stable nonowhiskers. The crystallinity of FPM and of NWMs was also observed in DRX, with increase of crystallinity of 254.87% and 165.62%, respectively when compared to FBM. The thermal stability increased with chemical treatments performed on FBM, and the NWM degradation occurred basically in only one step, indicating chemical and dimensional homogeneity of the sample. Nanocomposites formed by polymeric matrix of polyvinyl alcohol (PVA) and reinforcements of 2.5, 5 and 10% of NWM were compared to the PVA through thermal analysis (TG and DSC), infrared spectroscopy (FTIR), x-ray diffraction (DRX) and traction analysis. The thermal stability of nanocomposite with reinforcement of 5% of NWM increased. In FTIR analysis, the occurred bands are features of PVA. The diffractogram of DRX has shown an increase of nanocomposite crystallinity with less reinforcement of NWM, in a 38% -increase range. The mechanical properties have shown significant improvements in nanocomposites with NWM reinforcement. The nanocomposite formed with smaller amount of reinforcement has shown the highest modulus of elasticity and the nanocomposite formed with reinforcement of 5% of NWM has shown higher level of resistance and tensile breakdown. The present study has found that the use of the residual mass of potato starch manufacturers becomes a promising use in the production of nanowhiskers and incorporation of them in nanocomposites as reinforcement.
173

Pós-tratamento de efluentes por processos de separação por membranas e reúso de água em uma indústria de laticínios / Post-treatment wastewater by membrane technology and water reuse in a dairy industry

Galvão, Douglas Felipe 14 March 2016 (has links)
As indústrias de laticínios utilizam volume substancial de água para a realização dos processos produtivos, especialmente para a manutenção de condições de higiene e limpeza. Com isso, ocorre a geração de volume considerável de efluentes que demandam tratamento para atendimento dos padrões de lançamento antes de serem descartados. Com a escassez de recursos hídricos e a cobrança pelo uso da água, a minimização do consumo de água nas indústrias é de suma importância para manter sua competitividade no mercado. Nesse sentido, tem aumentado o interesse pelo reúso de efluentes, com o objetivo de diminuir o consumo de água de boa qualidade em processos que não exigem qualidade tão alta desse recurso. Os processos de separação por membranas têm destaque na geração de águas de reúso de boa qualidade e que podem atender a demanda de vários processos industriais. Desse modo, a presente pesquisa teve como objetivo avaliar os processos de separação por membranas como pós-tratamento de efluentes de uma indústria de laticínio com vistas ao reúso deste efluente. Para isso, foi realizada a caracterização físico-química e microbiológica dos efluentes da indústria de laticínios, a realização dos processos de separação por membranas de microfiltração (MF) e ultrafiltração (UF) e microfiltração seguida de ultrafiltração (MF+UF). Os processos de MF e UF foram realizados variando-se as condições de pressão aplicadas, realizando-se a avaliação da qualidade do efluente obtido após os processos de separação por membranas, considerando o atendimento à exigências técnicas, legais e sanitárias para diferentes usos industriais. Os resultados demonstraram que, os processos de MF e UF têm considerável eficiência no tratamento do efluente da indústria de laticínio, com eficiências que chegaram a 36,57% para nitrogênio total, 98,39% para óleos e graxas, 97,27% para DQO e 97,64% para DBO. A membrana de MF demonstrou eficiência máxima na remoção de DQO, DBO, nitrogênio amoniacal, fósforo, turbidez, óleos e graxas e sólidos totais voláteis de 97,27, 96,79, 73,96, 38,46, 100, 95,89 e 87,79%, respectivamente. A membrana de UF teve eficiência na remoção DQO, DBO, nitrogênio amoniacal, fósforo, turbidez, óleos e graxas, e sólidos totais voláteis de 97,27, 90,29, 70,81, 20,51, 100, 97,26 e 91,01%, respectivamente. Para as membranas de MF e UF foram obtidas eficiências de 100% na remoção de coliformes termotolerantes. Para o ensaio de MF seguida de UF nas melhores condições de operação determinadas, foram obtidos resultados bastante consideráveis para DBO, DQO, turbidez e sólidos totais voláteis, de 97,64, 97,29, 100 e 93,11%, respectivamente. As membranas de MF e UF apresentaram fluxos permeados bastantes semelhantes e, mesmo com o aumento da pressão, os fluxos permeados não apresentaram valores muito diferentes, sendo que as duas membranas de MF e UF tem bastante influência da incrustação em sua superfície, causando o rápido declínio do fluxo permeado. Mesmo com o tamanho do poro menor que o da membrana de MF, a membrana de UF apresentou fluxo permeado mais elevado que a MF. Comparando os resultados dos parâmetros físico-químicos e biológicos dos processos de MF e UF com os padrões de reúso de efluentes, houve atendimento satisfatório dos parâmetros para o reúso em caldeiras, torres de resfriamento, lavagem de pisos, irrigação de áreas verdes, lavagem de veículos, proteção contra incêndio e descarga sanitária. / The dairy industry uses substantial amount of water to achieve the production process, especially for the maintenance of hygiene and cleanliness conditions. With this, is generating considerable volume of wastewater requiring treatment to meet the discharge standards before discarded. With the shortage of water resources and charging for water use, minimizing water consumption in industries is of paramount importance to maintain its market competitiveness. In this sense, there has been increasing interest in the reuse of wastewater, in order to decrease the good water consumption by processes that do not require such high quality that feature. Membrane separation processes are highlighted in generating good quality reuse water that can meet the demand of various industrial processes. Thus, the present study aimed to evaluate the membrane separation processes such as post-treatment of dairy industry effluent with a view to reuse of this effluent. For this, the physical-chemical and microbiological characterization of the studied dairy wastewater was held, achieving the separation processes microfiltration membranes (MF) and ultrafiltration (UF), and microfiltration followed by ultrafiltration (MF + UF). The MF and UF processes were performed varying the pressure conditions applied, performing the evaluation of the quality of the effluent obtained after the separation of membrane processes, considering the compliance with technical, legal and sanitary requirements for different industrial uses. The results show that the MF and UF processes have considerable effectiveness in the treatment of the effluent from the dairy industry, with efficiencies reached 36.57% for total nitrogen, 98.39% for oils and greases, 97.27% for COD and 97.64% for BOD. The membrane MF demonstrated maximum efficiency in the removal of COD, BOD, ammonia nitrogen, phosphorus, turbidity, total volatile solids, oils and greases of 97.27, 96.79, 73.96, 38.46, 100, 95.89 and 87.79%, respectively. The UF membrane had removal efficiency of COD, BOD, ammonia nitrogen, phosphorus, turbidity, total volatile oils and greases and solids of 97.27, 90.29, 70.81, 20.51, 100, 97.26 and 91.01%, respectively. For membrane MF and UF 100% efficiencies were obtained in the removal of thermotolerant coliforms. For MF tests followed by UF with the best certain operating conditions, were obtained quite considerable results for BOD, COD, turbidity, and total volatile solids, 97.64, 97.29, 93.11 and 100%, respectively. MF and UF membranes showed quite similar permeate fluxes and even with increasing pressure, permeate flows had not very different values, while the two membranes MF and UF has enough influence of fouling on its surface, causing rapid decline in the permeate flux. Even with a pore size smaller than the MF membrane, UF membrane showed higher permeate flux than MF. Comparing the results of physico-chemical parameters and biological of MF and UF processes with the patterns of reuse of wastewater,there was satisfactory compliance with the parameters for reuse in boilers, cooling towers, floor washing, irrigation of green areas, washing vehicles, fire protection and sanitary discharge.
174

A geração de resíduos sólidos no festival gastronômico de Carlos Barbosa : o Festiqueijo

Néry, Carlos Henrique Cardona 12 September 2008 (has links)
Um evento (festa gastronômica) possui características de um empreendimento turístico que consome água, energia e insumos, gerando resíduos sólidos, emissões gasosas e água residuária. Assim, é importante a identificação das diferentes formas de impactos ambientais decorrentes de festas dessa natureza, no sentido de melhor contemplar a variável ambiental no planejamento das mesmas. O presente estudo se propõe avaliar a geração de resíduos sólidos em um festival gastronômico, que faz parte de um calendário turístico há mais de 19 anos (FESTIQUEIJO 2007 Festival gastronômico realizado na cidade de Carlos Barbosa, no estado do Rio Grande do Sul). Dessa forma, o problema inicial da pesquisa partiu da seguinte pergunta: como ocorre a geração de resíduos sólidos em um festival gastronômico? Para responder a pergunta foram realizadas caracterizações dos resíduos sólidos gerados durante o Festival, observação direta de todos os setores geradores de resíduos, identificação das condições de manejo de resíduos sólidos no âmbito da festa e entrevistas com visitantes (825 sujeitos). Os estudos sobre o diagnóstico da geração de resíduos sólidos, permitiu determinar a composição gravimétrica desses resíduos no evento, e como decorrência apontar ações de gerenciamento dos mesmos para os próximos festivais. As maiores frações de componentes presentes na composição dos resíduos sólidos são de vidro (81,79%), papel e papelão (5,49%), matéria orgânica putrescível (4,60%) e de plástico (4,05%). Também, os estudos apontam a responsabilidade legal e ética dos expositores, uma vez que os mesmos devem assumir o compromisso pela geração e manejo dos resíduos sólidos gerados em seus stands. O desenvolvimento desse estudo possibilita o preenchimento de lacunas existentes no turismo, principalmente no que tange ao tema ambiental no planejamento de eventos gastronômicos. / An event (gastronomical festival) has the characteristics of a touristic enterprise consuming water, energy and goods, which generate solid residues, gas emissions and residuary water. Thus the identification of the different forms of environmental impacts resulting from that kind of festival is important so that the environmental variable can be best evaluated when planning such events. The present study aims at the evaluation of solid residues generated in a gastronomical festival which has been part of the touristic calendar for over 19 years (FESTIQUEIJO 2007, a gastronomical festival held in the town of Carlos Barbosa, in the Rio Grande do Sul state). The research initial problem came from the question: how does the generation of solid residues occur in a gastronomical festival? To find the answer to that question, the solid residues generated during the festival were characterized, all the sectors generating them during were observed directly, the conditions for handling those residues in the festival environment were identified and visitors were interviewed (825 individuals). The study on the diagnosis of solid residues generation allowed for the determination of the gravimetric composition of the residues in the event, and consequently establish management actions for the next festivals. The largest fractions of components which were present in the composition of solid residues were: glass (81.79%), paper and cardboard (5.49%) putrefiable organic matter (4.60%) and plastic (4.05%). The studies also point to the ethical and legal responsibility of the participants, once they have to find themselves responsible for the generation and the handling of solid residues coming from their stands. The development of this study allows for filling in the existing gaps in tourism, specially regarding the environmental issue while planning for gastronomical events.
175

Utilização de pleurotus sajor-caju na redução da concentração de compostos fenólicos presentes no efluente da indústria de papel e celulose

Bonfanti, Patricia 13 December 2007 (has links)
Efluentes da indústria de papel e celulose (IPC) caracterizam-se por apresentar um alto conteúdo de compostos fenólicos que são prejudiciais para os microrganismos envolvidos nos tratamentos convencionais, necessitando a sua remoção por processos físicos e/ou químicos, antes do encaminhamento para as lagoas aeradas. Neste trabalho foi estudada a capacidade de degradação de fenol e de fenóis totais presentes no efluente da IPC, em cultivo submerso, pela linhagem de Pleurotus sajor-caju PS-2001 utilizada comercialmente para a produção de cogumelos. Também foi avaliado a alteração na concentração de DQO de efluentes da IPC por sistemas bacterianos aerados, após o tratamento fúngico. Foram realizadas análises de atividade de lacases, LiP, VAO e MnP, fenóis totais, pH, cor e DQO. Os estudos de crescimento de fungos e bactérias foram realizados em frascos agitados e em reator de bancada. A formulação do meio de crescimento fúngico continha 92% de efluente da IPC, suplementado com sais, glicose e proteína de soja. Em todos os ensaios observou-se uma diminuição da concentração de fenóis totais do meio, que foi interpretada como decorrente da ação do fungo pela atividade enzimática envolvendo degradação e precipitação, adsorção na massa fúngica e de atividade não biológica, desde que foram detectadas atividades de lacases, LiP, VAO e MnP; foi observado adsorção de fenóis totais pelo micélio; e também diminuição de fenóis totais na ausência de microrganismos. As análises de DQO e fenóis totais dos efluentes referentes aos ensaios com bactérias aeróbias, após o tratamento fúngico, mostraram uma diminuição de DQO mais rápida em relação ao efluente não tratado pelo fungo. A remoção de fenóis totais no processo bacteriano também foi favorecida pela ação fúngica, visto que a remoção dos compostos fenólicos foi superior no efluente tratado pelo fungo. Com base nos resultados obtidos, conclui-se que a atividade do fungo da degradação branca Pleurotus sajor-caju PS 2001 pode constituir-se como parte de um processo para tratamento de efluentes da IPC, associado ao tratamento bacteriano. / Wastewaters originated at paper and cellulose industries (PCI) are characterized by the presence of the high content of phenolics compounds, which assign prejudicial for the microorganisms involved in the conventional treatments, imposing physical and/or chemical removal before the discharge to the aerobic (secondary) pond. This work deals with the degradation capacity of phenol and total phenols present in the PCI wastewater, in submerged cultivation, by the strain of Pleurotus sajor-caju PS-2001, commercially utilized for the output of mushrooms. In addition, changes in the COD concentration in PCI wastewaters of aerobic bacterial systems treated with fungus were evaluated. Analyses of activity of laccases, LiP, VAO and MnP, total phenols, pH, colour and DQO were carried out. The fungi and bacteria growth studies were carried out using shaking flask and bioreactor. The formulation of the medium for fungus growth had 92% of PCI wastewater, supplemented with salts, glucose and soy protein. In all trials was observed a reduction in the concentration of total phenols in the medium, that may be caused by the enzymatic activity of the fungus, which involves degradation and haste, adsorption in the fungus mass and non-biological activity due to the fact that activities of laccases, LiP, VAO and MnP were detected; the adsorption of total phenols by the micelles was observed as well as a decrease in the total phenols in the absence of microorganisms. The COD and total phenols trial analyses of wastewaters with aerobic bacteria showed a faster decrease when treated with fungus, compared to the trials without fungus. Furthermore, the removal of total phenols in the bacterial trial was availed by the fungus action due to fact that the removal of the phenol compounds was higher in the wastewater treated with the fungus. Based in the obtained results, it was concluded that the white-rot fungus P. sajor-caju PS 2001 activity can be used as a part of the PCI wastewater treatment associated to the bacterial treatment.
176

Saúde pública e saneamento: um estudo de caso na cidade de Lins / Public health and sanitation: a case \'s study in the city of Lins

Lúcio Marcelo Faria Murja 16 October 2009 (has links)
A pesquisa acompanha e relaciona a evolução dos serviços de saneamento básico da cidade de Lins de forma paralela à incidência de internações e óbitos característicos de Doenças de Veiculação Hídrica (DVH), ocorridos no hospital Santa Casa de Misericórdia de Lins ao longo de três décadas (1975 a 2005) com quatro cortes temporais de dez anos. O período do estudo contempla o processo de universalização do saneamento básico na cidade que se deu em 1997 com a inauguração do sistema de tratamento de esgotos, que passou a tratar, além de toda a água distribuída ao município, todo esgoto coletado. Os resultados, com base em dados colhidos em livros de registro de internações do hospital e do número de ligações de água e esgoto junto a Companhia de Saneamento Básico do Estado de São Paulo (Sabesp) permitiram relacionar dentro do universo de atendimento do hospital qual a representatividade das doenças que interessavam ao estudo e estabelecer uma relação entre as condições de saneamento básico e saúde pública. Os resultados apresentaram co-relação entre o aumento do acesso ao saneamento e a saúde pública, com a diminuição do número de ocorrências de internações e óbitos por doenças que poderiam estar ligadas a ausência ou falta desses serviços. A comparação de registros de internações totais do hospital e as provocadas por DVH registraram queda na proporção de 4,32% em 1975, 1,86% em 1985, 1,76% em 1995 e 0,98% em 2005. Observamos, entretanto, que outros fatores também devem ser considerados como a incidência de casos por outras formas de contaminação, como a falta de práticas de higiene; a adoção de novos métodos de tratamento para esses tipos de enfermidade e o progressivo aumento da pressão sobre os recursos hídricos ao longo do período, devido ao crescimento populacional e desenvolvimento econômico do município (industrial e agrícola) que sem a devida universalização do sistema de saneamento causaria inúmeras outras ocorrências de DVH. Todos esses fatores junto aos resultados da pesquisa mostram que o investimento em saneamento básico é também um investimento em medicina preventiva, que do ponto de vista da saúde pública, representa custos inferiores aos alocados para a medicina curativa. Além deste aspecto contribuem para melhoria da qualidade de vida, com o desenvolvimento social e econômico da comunidade beneficiada. / The search accompanies and relates the evolution of basic sanitation services from Lins´s city of parallel form to incidence of admissions and deaths characteristic of Hydric Vehiclelation Illness (HVI), has occurred at Lins Misericordia Santa Casa Hospital along for three decades (1975-2005) with four cross-temporal of ten years. The period of study has contemplated the basic sanitation `s universalization process in the city that it is given in 1997 with the inauguration of drainage treatment system, which passed to treat, besides all water distributed to borough, all drained collected. The results, with base in data gather in books of admissions´s register and number of ligations of water and drained together to São Paulo State`s Basic Sanitation Company (Sabesp) had permitted to relate in universe of hospital`s service what the representative of illnesses that it had interested to study and to establish a relation among the conditions of basic sanitation and public health. The results presented co-relation between the number of access to sanitation and the public health, with the diminution of occurrence`s numbers of admissions and deaths by illnesses that could be linked to absent and failure these services. The comparison of total admissions registers and the provoked by IVH has registered drop in proportion 4.32% in 1975, 1.86% in 1985, 1.76% in 1995 and 0.98% in 2005. We have observed, therefore, who other factors must be considered as the incidence of cases by other contamination forms, as a hygiene practice`s failure; the adoption of new methods of treatment to these infirmity`s types and the increase progressive of pressure on the hydric recourses long of period, due at populational increasing and economic development of borough (industrial and agricultural) that without a due universalization of sanitation`s system would cause numberless other occurrences of IVH. Every these factors together to resulted of search has showed that the investment in basic sanitation is also an investment in preventive medicine, which of point view of public health, has represented inferior costs to allocated to the curetive medicine. Besides this aspect has contribute to improvement of life`s quality, with the social and economic development of benefitted community.
177

Identificação e verificação da resistência aos sanitizantes dos microrganismos presentes na água destinada ao abastecimento público e em um sistema de purificação / Identification and verification of resistance to the sanitizers of microorganisms present in the water for public supply and a purification system

Alzira Maria da Silva Martins 14 October 2002 (has links)
Água purificada para uso em ambientes de saúde e preparação industrial de produtos médico-odonto-hospitalar deve ter uma carga reduzida de contaminação microbiológica e pirogênio. As amostras analisadas foram coletadas em 13 (treze) diferentes estágios de um sistema de purificação de água, sendo isoladas 78 colônias. Para a identificação dos microrganismos foram utilizados: (i) identification system for non-enteric gram-negative rods (api 20 NE, bio Mérieux) e (ii) identification system for enteric and nonfermenter (BBL crystal, Becton Dickinson). De acordo com os resultados pode-se observar uma maior prevalência para Pseudomonas aeruginosa 32,05% (25 colônias dentre as 78 isoladas); Pseudomonas picketti 23,08% (18); Pseudomonas vesiculares 12,82% (10); Pseudomonas diminuta 11,54% (09); Flavobacterium aureum 6,42% (05); Pseudomonas fluorescences 5,13% (04); Acinetobacter Iwoffi 2,56% (02); Pseudomonas putida 2,56% (02); Pseudomonas alcaligenes 1,28% (01); Pseudomonas paucimobilis 1,28% (01), Flavobacterium multivorum 1,28% (01). A eficácia dos agentes sanitizantes utilizados para higienização dos diferentes pontos foi determinada pela concentração inibitória mínima (CIM) e tempo de redução decimal (valor D). Como o hipoclorito de sódio é largamente utilizado na higienização do tanque de água de alimentação, tanque de estocagem da água purificada e nas linhas de distribuição aos pontos de uso, este foi testado frente a todos os microrganismos sendo observado menor resistência para Escherichia coli ATCC 25922 (0.06%=600mg/L), quando comparada a P. aeruginosa isolada e identificada (O,25%=2500mg/L). O tempo de redução decimal (Valor D) da Escherichia coli ATCC 25922 foi de 4 minutos e o valor D da P. aeruginosa isolada e identificada e isolada in house foi de 9 minutos. / The samples of water, which were taken directly from the public distribution water tank and at twelve different stages of a typical purification system, were analyzed for the identification of isolated bacteria. The efficacy of the chemical sanitizers used in the stages of the system, over the isolated and identified bacteria in the sampling water, was valuated by the minimum inhibitory concentration (MIC and decimal reduction time (D-values). According to the miniature kits used in the identification, there was a prevalence of isolation by P. aeruginosa 32,05 % , P. picketti (Ralstonia picketti) 23,08%, P. vesiculares 12,82%, P. diminuta 11.54%, F.aureum 6,42%, P.fluorescens 5,13%, A.lowffi 2,56%, P.putida 2,56%, P. alcaligenes 1,28%, P.paucimobilis 1,28%, and F. multivorum 1,28%. The efficacy of the agents varied with the concentration and time of contact to reduce a decimal logarithmic (loglO) population (n cycles): (i) 0.5% citric acid (0= 4 min) for 30 min reduced n=7 cycles; (ii) 0.5% chloridric acid (0= 6 min) for 30 min reduced n= 4 cycles; (iii) 70% alcohol (0= 9 min) for 1.0 min (n=0.2 cycles); (iv) 0.5% sodium bisulphite (0= 6 min) for 90 min (n=14 cycles); (v) 0.4% sodium hydroxide (0= 8 min) for 30 min (n=3.0 cycles); (vi) 0.5% sodium hypochlorite (0=9 min) for 180 min (n = 19 cycles); (vii) mixture of hydrogen peroxide (2,2%) plus peracetic acid (0.45%), 0= 6 min, contact time of 180 min, reduced n = 32 cycles of the population. The sterility assurance level (SAL) of 10-6 was attained for the 0.5% sodium hypochlorite solution applied in the water purified storage tank and distribution loop; and for the mixture of H2O2 plus peracetic acid, used in the reverse osmose and in the deionizator systems.
178

Identificação e verificação da resistência aos sanitizantes dos microrganismos presentes na água destinada ao abastecimento público e em um sistema de purificação / Identification and verification of resistance to the sanitizers of microorganisms present in the water for public supply and a purification system

Martins, Alzira Maria da Silva 14 October 2002 (has links)
Água purificada para uso em ambientes de saúde e preparação industrial de produtos médico-odonto-hospitalar deve ter uma carga reduzida de contaminação microbiológica e pirogênio. As amostras analisadas foram coletadas em 13 (treze) diferentes estágios de um sistema de purificação de água, sendo isoladas 78 colônias. Para a identificação dos microrganismos foram utilizados: (i) identification system for non-enteric gram-negative rods (api 20 NE, bio Mérieux) e (ii) identification system for enteric and nonfermenter (BBL crystal, Becton Dickinson). De acordo com os resultados pode-se observar uma maior prevalência para Pseudomonas aeruginosa 32,05% (25 colônias dentre as 78 isoladas); Pseudomonas picketti 23,08% (18); Pseudomonas vesiculares 12,82% (10); Pseudomonas diminuta 11,54% (09); Flavobacterium aureum 6,42% (05); Pseudomonas fluorescences 5,13% (04); Acinetobacter Iwoffi 2,56% (02); Pseudomonas putida 2,56% (02); Pseudomonas alcaligenes 1,28% (01); Pseudomonas paucimobilis 1,28% (01), Flavobacterium multivorum 1,28% (01). A eficácia dos agentes sanitizantes utilizados para higienização dos diferentes pontos foi determinada pela concentração inibitória mínima (CIM) e tempo de redução decimal (valor D). Como o hipoclorito de sódio é largamente utilizado na higienização do tanque de água de alimentação, tanque de estocagem da água purificada e nas linhas de distribuição aos pontos de uso, este foi testado frente a todos os microrganismos sendo observado menor resistência para Escherichia coli ATCC 25922 (0.06%=600mg/L), quando comparada a P. aeruginosa isolada e identificada (O,25%=2500mg/L). O tempo de redução decimal (Valor D) da Escherichia coli ATCC 25922 foi de 4 minutos e o valor D da P. aeruginosa isolada e identificada e isolada in house foi de 9 minutos. / The samples of water, which were taken directly from the public distribution water tank and at twelve different stages of a typical purification system, were analyzed for the identification of isolated bacteria. The efficacy of the chemical sanitizers used in the stages of the system, over the isolated and identified bacteria in the sampling water, was valuated by the minimum inhibitory concentration (MIC and decimal reduction time (D-values). According to the miniature kits used in the identification, there was a prevalence of isolation by P. aeruginosa 32,05 % , P. picketti (Ralstonia picketti) 23,08%, P. vesiculares 12,82%, P. diminuta 11.54%, F.aureum 6,42%, P.fluorescens 5,13%, A.lowffi 2,56%, P.putida 2,56%, P. alcaligenes 1,28%, P.paucimobilis 1,28%, and F. multivorum 1,28%. The efficacy of the agents varied with the concentration and time of contact to reduce a decimal logarithmic (loglO) population (n cycles): (i) 0.5% citric acid (0= 4 min) for 30 min reduced n=7 cycles; (ii) 0.5% chloridric acid (0= 6 min) for 30 min reduced n= 4 cycles; (iii) 70% alcohol (0= 9 min) for 1.0 min (n=0.2 cycles); (iv) 0.5% sodium bisulphite (0= 6 min) for 90 min (n=14 cycles); (v) 0.4% sodium hydroxide (0= 8 min) for 30 min (n=3.0 cycles); (vi) 0.5% sodium hypochlorite (0=9 min) for 180 min (n = 19 cycles); (vii) mixture of hydrogen peroxide (2,2%) plus peracetic acid (0.45%), 0= 6 min, contact time of 180 min, reduced n = 32 cycles of the population. The sterility assurance level (SAL) of 10-6 was attained for the 0.5% sodium hypochlorite solution applied in the water purified storage tank and distribution loop; and for the mixture of H2O2 plus peracetic acid, used in the reverse osmose and in the deionizator systems.
179

A técnica de Blue rayon in situ associada ao teste Salmonella/microssoma como estratégia para o monitoramento de águas estuarinas quanto à presença de compostos policíclicos genotóxicos / The Blue rayon technique in situ associated with the Salmonella / microsome test as a strategy for monitoring estuarine waters for the presence of genotoxic polycyclic compounds

Kummrow, Fábio 07 March 2006 (has links)
O estuário de Santos abriga o maior porto da América Latina e um dos maiores complexos industriais do Brasil. Na década de 1970 foi considerado um dos maiores exemplos de degradação ambiental em ambientes costeiros, e apesar da melhora na qualidade ambiental observada nos últimos anos algumas áreas deste estuário apresentam sedimentos ainda altamente contaminados com compostos tóxicos e genotóxicos, especialmente os Hidrocarbonetos Policíclicos Aromáticos (HPA). Operações de dragagem para manutenção das atividades portuárias são necessárias e consequentemente durante este processo pode ocorrer a ressuspensão de contaminantes presentes nesses sedimentos, tornando-os disponíveis novamente na coluna d\'água. Desta forma é interessante ter uma estratégia eficiente e aplicável no monitoramento da qualidade dessas águas. O Blue rayon (BR) é um adsorvente seletivo para compostos policíclicos com três ou mais anéis fundidos em sua molécula e tem sido utilizado com sucesso no monitoramento de HPA e atividade mutagênica em ambientes aquáticos. Este trabalho teve como objetivo padronizar o uso da técnica de Blue rayon in situ ancorado, onde as fibras são fixas a uma distância padronizada dos sedimentos, associada ao teste de Salmonella/microssoma em microssuspensão a ser aplicada no monitoramento das águas desse estuário. Foram selecionados três pontos de amostragem com diferentes características e sedimentos com variados níveis de contaminação. As duas campanhas iniciais foram realizadas com o objetivo de avaliar a eficiência do BR e de escolher a linhagem de Salmonella mais sensível aos compostos mutagênicos possivelmente presentes nos extratos obtidos bem como verificar a presença de HPA. As cinco campanhas posteriores foram realizadas para verificar o comportamento e a eficiência da estratégia previamente definida no monitoramento das águas desse estuário utilizando experimentos de dose resposta. Os resultados obtidos nas duas primeiras campanhas mostraram que as águas do ponto 1, que contém os sedimentos mais contaminados e recebe os efluentes da COSIPA, apresentam maior contaminação por HPA e atividade genotóxica mais elevada que o ponto 2. Também foi possível determinar que a linhagem de Salmonella YG1041 foi a mais sensível para detectar atividade mutagênica tanto no ponto 1 quanto no ponto 2. Nas cinco campanhas subsequentes as maiores potências mutagênicas foram também observadas no ponto 1 com valores máximos de 5.100 e 36.000 revertentes/g de BR para a linhagem YG1041 na ausência e na presença de ativação metabólica (S9) respectivamente. Nos pontos 2 e 3 as potências observadas foram similares entre si, com valores em torno de 1.000 revertentes/g de BR. Com base nos resultados obtidos nas duas etapas deste trabalho pode-se concluir que a o Blue rayon utilizado in situ a uma distância padronizada dos sedimento associado ao teste de Salmonella/microssoma em microssuspensão com a linhagem YG1041 na presença e na ausência de ativação metabólica (S9) é uma ferramenta que pode ser aplicada no monitoramento da qualidade do estuário de Santos. / Santos estuary is the major Latin American harbor and one of the largest industrial complex of Brazil. In the 1970s, it was considered one of the major examples of coastal degradation. Due to enforcement actions the quality of the environment has improved in the last years in relation to the chemical parameters and toxicity but unfortunately the sediment is still contaminated with toxic and genotoxic compounds especially Polycyclic Aromatic Hydrocarbons (PAHs). For the maintenance of the port activities sediment dredging is needed and during this process contaminants resuspension can occur, leading to the contamination of the water column. Therefore it is interesting to have an efficient strategy that can be used for the water quality monitoring of this area. The Blue rayon is a selective adsorbent to polycyclic compounds containing three or more fused rings and has been successfully used in the monitoring of PAHs and mutagenic activity in aquatic environments. The objective of this work was to evaluate a modified blue rayon hanging technique, denominated in this work \"Blue rayon anchored technique\", where the fibers are placed at a fixed distance from the sediment, associated with the Salmonella/microsome microsuspension assay in order to monitor the water quality of Santos estuary. Three sites with different sources and sediment contamination levels were selected in this study. Two initial samplings were performed in order to evaluate the efficiency of the BR modified technique and find the most sensitive strain of Salmonella typhimurium to the mutagens possibly present in the those waters as well as verify the presence of PAHs. Five subsequent samplings were performed to verify the performance and efficiency of the defined strategy in the estuary water quality monitoring using dose response experiments. In the two initial samplings, the water from the site containing the most contaminated sediment and under influence of COSIPA (site 1) presented higher mutagenic activity and higher levels of PAHs. It was also possible to verify the highest sensitivity of the YG1041 strain in the detection of the mutagenic activity in both sites analyzed. In the subsequent five samplings, higher mutagenic potencies were again observed for site 1, reaching 5,100 and 36,000 revertants per gram of BR for the YG1 041 strain in the absence and presence of S9 respectively. Sites 2 and: presented similar potencies, around 1000 revertants per gram of BR. Based on the obtained results we can conclude that the Blue rayon anchored technique associated with the Salmonella/microsome microsuspension assay with the YG1041 strain in the presence and absence of S9 is an suitable tool to monito Santos estuarine waters.
180

Desenvolvimento de método para determinação de nitrosaminas em águas de interesse à saúde pública / Method development for the determination of nitrosamines in water of interest to public health

Nascimento, Heliara Dalva Lopes do 05 December 2003 (has links)
Entre os compostos orgânicos tóxicos possíveis de serem encontrados em águas de consumo humano, estão as nitrosaminas, substâncias nitrogenadas originárias da reação de aminas com compostos nitrosantes e de dificil detecção pelos métodos convencIOnaIs. O objetivo deste estudo foi desenvolver uma metodologia de rotina alternativa para a determinação de nitrosaminas em águas e a aplicação deste procedimento em algumas amostras de interesse à Saúde Pública. Um minucioso estudo e otimização dos parâmetros envolvidos na detecção e separação cromatográfica empregando o detector de quimiluminescência induzida por ozônio ou Thermo Energy Analyser (TEA), permitiram melhorar em 10 vezes a sensibilidade deste equipamento, permitindo assim a análise de traços de nitrosaminas, com o auxílio de uma pré-concentração da amostra e sem a necessidade do dessorvedor térmico. Comparativamente a outros detectores, o uso do GCffEA elimina as várias etapas necessárias para a descontaminação de material, requisitadas no uso do NPD e apresenta sensibilidade compatível com as técnicas de espectrometria de massas empregadas (High Resolution Mass Spectroscopy (HRMS) e Positive Chemical Ionization Mass Spectroscopy (PCI MS)), com a vantagem de uma operação mais simples e de menor custo. Para o alcance do objetivo, a utilização do planejamento de experimentos foi uma ferramenta fundamental. Por intermédio dela, os parâmetros críticos, como o fluxo de gases, temperatura de pirólise, etc. das principais etapas envolvidas no processo analítico, puderam ser estudados e otimizados. A metodologia proposta para a análise de traços de nitrosaminas em águas empregando GC/TEA mostrou boa especificidade, linearidade e precisão adequada com coeficientes de variação, na análise cromatográfica, na faixa entre 6 a 12% para as nitrosaminas voláteis analisadas. Considerando o propósito das análises, os limites de detecção alcançados foram adequados, como por exemplo, 0,2 ngL-l para a N-nitrosopiperidina e 2,0 ngL-I para a N-nitrosopropilamina levando em conta a recuperação obtida na etapa de pré-concentração. O método foi aplicado em amostras de água tratada, água bruta de reservatório e de rio, água de poço artesiano e extratos orgânicos provenientes de amostras de águas bruta e tratada. Algumas nitrosaminas voláteis de interesse toxicológico foram detectadas, como por exemplo, a N-nitrosodimetilamina (NUMA), que foi encontrada, dependendo da amostra, em concentrações menores que 0,3 ngL-1, limite de detecção, até 5,0 ngL-1. / Among the poisonous organic compounds liable to be found in waters of human consumption, are the nitrosamines, nitrogenous substances originated from amine reaction with nitrousing compounds, and of difficult detection by the conventional methods. The scope of this study was to develop an altemative routine methodology for the nitrosamine determination in waters and the application of this procedure in some samples of interest to the Public Health. A meticulous study and optimization of the parameters involved in the detection and chromatographic separation using a chemiluminescense detector induced by ozone or Thermo Energy Analyser (TEA), allowed a 10 times improvement in the sensibility of this equipment, allowing trace analysis of nitrosamines, with the aid of a pre-concentration of the sample and without the need of the thermal desorber. Comparing to other detectors, the use of GC/TEA eliminates several necessary stages for material decontamination, required in the use of NPD and it comparable presents sensibility with such Mass Spectrometric techniques as High Resolution Mass Spectroscopy (HRMS) and Positive Chemical Ionization Mass Spectroscopy (PCI MS), with the advantage of simpler operation at lower cost. To achieve the objective, the use of statistical of experimental design was a fundamental tool. By means of it, the criticall parameters, such as the gas flow rate, pyrolysis temperature, among others involved in the analytical process, could be studied and optimized. The methodology proposed for the analysis of nitrosamine traces in waters using GC/TEA showed good specificity, linearity and appropriate precision with a coefficient variation, in the chromatographic analysis, in the range between 6 and 12% for the analyzed volatile nitrosamines. Considering the purpose of the analyses, the detection limits reached were appropriate, as for instance, 0,2 ngL-1 for N-nitrosopyperidine and 2,0 ngL-1 for N-nitrosopropylamine taking into account the recovery obtained in the pre-concentration stage. The method was applied to samples of treated water, raw water of reservoirs and rivers, water of artesian wells and organic extracts coming from samples of treated and raw waters. Some volatile nitrosamines of toxicological interest were detected, as for instance, N-nitrosodimethylamine (NDMA), that was found, depending on the sample, in concentrations below the 0,3 ngL-1 (detection limit) till up to 5,0 ngL-1.

Page generated in 0.0698 seconds