• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 453
  • 10
  • 9
  • 8
  • 8
  • 4
  • 4
  • 2
  • 1
  • 1
  • Tagged with
  • 476
  • 201
  • 145
  • 123
  • 105
  • 102
  • 98
  • 98
  • 89
  • 85
  • 68
  • 64
  • 63
  • 59
  • 55
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
321

Desnitrificação em filtro anaeróbio / Denitrification in anaerobic filter

Silva, Jenifer Clarisse Pereira da, 1982- 25 August 2018 (has links)
Orientador: Adriano Luiz Tonetti / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-25T10:04:23Z (GMT). No. of bitstreams: 1 Silva_JeniferClarissePereirada_M.pdf: 2338520 bytes, checksum: 3b813a7bd30065fc1d8de4c21453a377 (MD5) Previous issue date: 2014 / Resumo: O nitrogênio é um nutriente essencial para crescimento dos organismos, pois é parte da estrutura de proteínas e base do DNA. Liberado no meio aquático, este elemento pode causar diversos problemas como eutrofização de lagos, intoxicação de peixes e sua forma oxidada pode causar a meta-hemoglobinemia. A desnitrificação é uma alternativa de remoção de nitrato presente em efluentes. Nesta pesquisa foi estudada a desnitrificação utilizando um filtro anaeróbio com recheio de cascas de coco verde (Cocos nucifera), trabalhando com Tempo de Detenção Hidráulico (TDH) de 16 horas. A matriz avaliada era composta por efluente nitrificado em filtros de areia juntamente com esgoto bruto, que servia como fonte de carbono. A pesquisa foi dividida em 5 etapas: Etapa 1 - Somente aplicação de esgoto bruto no reator desnitrificante; Etapa 2 ¿ Aplicação de 87,5% de esgoto bruto e 12,5% de efluente nitrificado; Etapa 3 ¿ Aplicação de 75,0% de esgoto bruto e 25,0% de efluente nitrificado; Etapa 4 ¿ Aplicação de 62,5% de esgoto bruto e 37,5% de efluente nitrificado; Etapa 5 ¿ Aplicação de 50,0% de esgoto bruto e 50,0% de efluente nitrificado. O filtro anaeróbio fomentou a desnitrificação em todas as porcentagens de aplicação de efluente nitrificado com remoção de 67% de nitrogênio total e 98% de nitrato, bem como remoção de DQO de 72% (média de remoção de todas as etapas conjuntamente). O filtro anaeróbio também apresentou rápida aclimatação da biomassa desnitrificante com remoção de 49% de ?"N-NO" ?_"3" ^"-" na primeira semana de aplicação do efluente nitrificado / Abstract: Nitrogen it is an essential nutrient for growing organisms, because comprises the proteins structure and DNA basis. In case nitrogen is released into aquatic environment, it can cause eutrophication of lakes as well as fish poisoning and nitrogen in oxidized form can lead to methemoglobinemia. Denitrification remains an alternative for the removal of this compound. Thus, in this research we studied the denitrification in an anaerobic filter filled with green coconut husks (Cocos nucifera), operated with hydraulic retention time (HRT) of 16 hours. Its influent consisted of nitrified effluent came from intermittent sand filters, and raw effluent used as carbon source. We conducted the research in 5 steps: Step 1 ¿ Application of only raw effluent in the denitrifying reactor; Step 2 ¿ Application of 87.5% of wastewater and 12.5% of nitrified effluent; Step 3 ¿ Application of 75.0% of wastewater and 25.0% of nitrified effluent; Step 4 ¿ Application of 67.5% of wastewater and 37.5% of nitrified effluent; Step 5 ¿ Application of 50% of wastewater and 50% of nitrified effluent. The anaerobic filter allowed the removal of 67% of the total nitrogen and 98% of the nitrogen in the nitrate form as well as 72% COD removal (average removal in all steps). Denitrifying bacteria were quickly acclimated because in the first week denitrification, occurred 49% ?"N-NO" ?_"3" ^"-" were removed / Mestrado / Saneamento e Ambiente / Mestra em Engenharia Civil
322

Protótipo de biofiltro percolador com uso de meio suporte sintético / Prototype of biofilter percolator with synthetic support

Bergamini, Natália Cedran, 1984- 26 August 2018 (has links)
Orientador: Carlos Gomes da Nave Mendes / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-26T02:02:33Z (GMT). No. of bitstreams: 1 Bergamini_NataliaCedran_M.pdf: 5745897 bytes, checksum: 69560c23a66d8d968b36f4b34e17bc8d (MD5) Previous issue date: 2014 / Resumo: Este trabalho consistiu em inovação tecnológica antes nunca testada desde a concepção, projeto, construção e operação de um biofiltro percolador de tratamento de esgoto sanitário em escala piloto. O reator foi desenvolvido nas instalações do Laboratório de Protótipos da Faculdade de Engenharia Civil da UNICAMP, cidade de Campinas, estado de São Paulo, é constituído de pré-filtro fabricado com a manta acrílica resinada, 3 reatores biológicos percoladores dispostos em séries, revestidos de não tecido sintético e filtro secundário confeccionado do mesmo material do pré-filtro. A vazão real média de alimentação do sistema era de 12,8 L h-1, tendo sido operado em regime hidráulico com tempo de detenção hidráulico variável de 82 a 100 minutos. A inovação baseou-se no uso de não tecido sintético com tripla função: a) proporcionar o fluxo do substrato sob ação da gravidade; b) promover a troca gasosa entre o meio líquido e a atmosfera; e c) constituir-se como meio suporte da biomassa, além de verificar as condições operacionais e tipos de mantas para viabilizar o tratamento de esgoto na remoção de matéria carbonácea sem a necessidade de aeração artificial. Neste estudo, foi analisada a remoção de sólidos suspensos (SS), turbidez, oxigênio dissolvido, DQO e DBO5. Os resultados médios de remoção de DQO e de DBO nas diferentes fases operacionais variaram de 75 a 86% e de 80 a 86%, respectivamente. As concentrações médias de DQO no efluente final variaram de 81 a 179 mg/L, enquanto as concentrações médias de DBO estiveram entre 47 a 97 mg/L. As médias globais de SST no efluente final foram mantidas em 49 mg/L. Com remoção de turbidez de 92,8%. O sistema PF/FBP (Pré-filtro/Filtro Biológico Percolador) pode se tornar uma alternativa muito promissora para o tratamento de esgoto sanitário de pequenas instalações do Brasil, uma vez que o sistema manifestou baixos tempo de detenção hidráulica e eficiência na remoção de DQO, DBO5 e sólidos suspensos, resultando em uma instalação compacta e de baixos custos. Além disso, o consumo de energia e os custos operacionais são mínimos / Abstract: This work consisted in technological innovation never before tested from conception, design, construction and operation of a trickling biofilter wastewater treatment in pilot scale. The reactor was developed on the premises of the Laboratory Prototypes of the Faculty of Civil Engineering, UNICAMP, Campinas, São Paulo, is constituted of prefilter manufactured with resin-coated acrylic blanket, three biological trickling reactors arranged in series, coated and synthetic nonwoven secondary filter made of the same material pre-filter. The average real power flow of the system was 12,8 L h-1, having been operated hydraulic system with variable hydraulic detention time of 82-100 minutes. The innovation is based on the use of non-synthetic fabric with three functions: a) providing the flow of the substrate under the action of gravity; b) promote gas exchange between the liquid medium and the atmosphere; c) to establish itself as a means of support biomass and to check the operating conditions and types of blankets to enable wastewater treatment for the removal of carbonaceous matter without the need for artificial aeration. In this study, we analyzed the removal of suspended solids (SS), turbidity, dissolved oxygen, COD and BOD5. The average results of COD removal and BOD in the different operational phases ranged 75-86% and 80 to 86%, respectively. The average concentrations of COD in the final effluent ranged 81-179 mg/L, while the average concentrations of BOD were between 47-97 mg/L. Global average of TSS in the final effluent were maintained on 49 mg/L. To remove turbidity of 92.8%. The PF / BTF (Pre-filter / Biological trickling filter) system can become a very promising alternative for treating sewage from small installations from Brazil, once the system showed low hydraulic retention time and removal efficiency of COD , BOD5 and suspended solids, resulting in a compact installation and low costs. Furthermore, the energy consumption and operating costs are minimal / Mestrado / Saneamento e Ambiente / Mestra em Engenharia Civil
323

Eficiência energética em estações elevatórias de esgotos = estudo de caso em Uberlândia-MG / Energy efficiency in pumping stations sewage : a case study in Uberlândia-MG

Massulo, Adélia Mara 19 August 2018 (has links)
Orientador: Alberto Luiz Francato / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-19T01:12:20Z (GMT). No. of bitstreams: 1 Massulo_AdeliaMara_M.pdf: 15022902 bytes, checksum: 7c1463ac65523e398127a0f4bbcdbba4 (MD5) Previous issue date: 2011 / Resumo: A operação adequada de um sistema de coleta e afastamento de esgoto está diretamente relacionado a otimização do custo de operação do mesmo. Tendo em vista a utilização de equipamentos como: inversores de frequência e painéis de controle a distância para estações elevatórias de esgotos de grande porte e da inviabilidade financeira de instalar-se tais dispositivos em estações elevatórias de esgoto de pequeno e médio porte, a otimização surge como alternativa para buscar soluções eficientes e eficazes na operação do sistema. Na literatura relacionada ao assunto, verifica-se o desenvolvimento de diversos trabalhos com a aplicação e o desenvolvimento de rotinas computacionais de otimização específicas para o sistema de abastecimento de água. Contudo observa-se que ainda não existe o mesmo empenho para desenvolvimento de trabalhos voltados a eficiência operacional e energética em estações elevatórias de esgoto. Diante desse quadro, o presente trabalho tem como propósito aplicar uma rotina computacional de otimização que atenda as necessidades de estações elevatórias de esgoto. A metodologia utiliza a programação não linear, inteira e mista. O estudo de caso é feito com estações elevatórias de esgoto do município de Uberlândia-MG. Como resultado, foi obtida uma operação eficiente, que atende a todas as restrições impostas ao modelo, obtendo uma economia média de energia elétrica nas duas estações elevatórias de esgotos utilizadas para modelagem de vinte e dois por cento / Abstract: Proper operation of a system of collection and removal of sewage is directly related to the optimization of its operation. Given the use of equipment such as AC drives and control panels the distance to sewage pumping stations and large financial viability of installing such devices to sewage pumping stations in small and medium optimization arises to seek alternative solutions in efficient and effective operation of the system. In the literature related to the subject, there is the development of several works in the implementation and development of computational optimization routines specific to the water supply system. However it is observed that there is still the same commitment to development work aimed at operational and energy efficiency in sewage pumping stations. Against this background, this paper aims to apply a computer optimization routine that meets the needs of sewage pumping stations. The methodology to nonlinear programming, integer and mixed. The case study is done with the sewage pumping stations Uberlândia-MG. As a result, we obtained an efficient operation that meets all the restrictions imposed on the model, achieving an average savings of electric energy in the two sewage pumping stations used for modeling of twenty-two percent / Mestrado / Recursos Hidricos, Energeticos e Ambientais / Mestre em Engenharia Civil
324

Avaliação do desempenho da modificação de um sistema de tratamento de esgoto composto por tanque séptico e filtro anaeróbio por um modelo de aeração compartimentada / Performance evaluation of the modification of a sewage treatment system consisting of septic tank and anaerobic filter for a model compartimentalized aeration

França, Josue Tadeu Leite 20 August 2018 (has links)
Orientador: Ronaldo Stefanutti / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-20T00:18:11Z (GMT). No. of bitstreams: 1 Franca_JosueTadeuLeite_D.pdf: 5624209 bytes, checksum: 5cf73703ce197d3837470af4dd88e602 (MD5) Previous issue date: 2012 / Resumo: Este trabalho tem como objetivo avaliar o desempenho da modificação concernente a um processo de tratamento "tanque séptico seguido de filtro anaeróbio", no Distrito Bom Retiro, município de Angatuba, região sudoeste do Estado de São Paulo, por um modelo aerado, com aproveitamento integral das unidades existentes após pequenas adequações, visando atender a legislação e com baixo nível de operação. O sistema foi baseado em alguns parâmetros utilizados em lagoas aeradas e parcialmente aeradas. A remoção do lodo para a proposta é anual ou quando o sistema atingir os limites dos parâmetros de controle operacional: DBO efluente ? 60 mg O2 L-1 ou eficiência de remoção dos SST ? 80%. Após um ano de operação da proposta parcialmente concluída (sem tratamento preliminar), apesar de não atingir os limites máximos estabelecidos foram realizadas a quantificação e remoção do lodo gerado. O sistema de desaguamento foi realizado em uma série de "BAGs" verticais de polipropileno reutilizáveis por até 20 vezes, com capacidade para 2m³. Após as adequações, os resultados na segunda etapa do experimento com relação à DBO afluente e efluente, sólidos em suspensão total efluente (SST), residual de oxigênio dissolvido na saída do tanque de polimento, densidade de potência utilizada, custo de energia per capta (kWh ano-1) e custo de implantação per capta foram: DBO afluente e efluente teve como média e desvio padrão 674 ± 137 mg O2 L-1 e 22 ± 5 mg O2 L-1, respectivamente. A média aparada com relação ao residual de oxigênio dissolvido foi de 3,6 ± 1,2 mg L-1, a densidade de potência 42 W m-3, o consumo de energia foi de 56 kWh hab-1 ano-1 e o custo de implantação per capita foi de R$ 140,00. A proposta visa a adequação dos sistemas (tanque séptico + filtro anaeróbio) e implantação em pequenas comunidades, sem sistemas de tratamento de esgotos / Abstract: This work aims to evaluate the performance concerning the modification of the a treatment process "septic tank followed by anaerobic filter", in Bom Retiro district, municipality of Angatuba, and southwest of São Paulo, by aerated model with full use of existing units after minor adjustments, to meet the rules environmental and low level of operation. The system is based on some parameters used in aerated lagoons and partly aerated lagoons. The sludge removal is proposed for the year or when the system reaches the limits of the parameters of operational control: ? 60 mg O2 L-1 BOD effluent and TSS removal efficiency of ? 80%. After a year of operation of the proposed partially completed (without pre-treatment) did not reach the ceilings was conducted to quantify and removal of sludge generated. The dewatering system was conducted in a number of "BAGs" vertical polypropylene reusable for up to 20 times, with a capacity of 2 m³. After the adjustments results in the second stage of the experiment with respect to the influent and effluent BOD, total suspended solids effluent (TSS), residual dissolved oxygen in the tank outlet polishing, power density used, energy cost per capita (kWh year -1) and cost of deployment per capita were: influent and effluent BOD was mean and standard deviation 674 ± 137 mg O2 L-1 and 22 ± 5 mg O2 L-1, respectively. The mean residual trimmed with respect to dissolved oxygen was 3.6 ± 1,2 mg L-1, the power density 42 W m-3, the power consumption was 56 kWh. hab-1 year -1 and implementation cost per capita of R$ 140.00. The proposal aims adequacy of systems (septic tank + anaerobic filter) and deployment in small communities without sewage treatment systems / Doutorado / Saneamento e Ambiente / Doutor em Engenharia Civil
325

Avaliação da toxicidade de efluente sanitário tratado e condicionado para aplicação na agricultura, utilizando Allium cepa, Daphnia similis e Vibrio fischeri, como organismos-teste / Toxicity assessment of treated sanitary effluent for application in agriculture, using Allium cepa, Vibrio fischeri and Daphnia similis as test organisms

Torres, Danila de Leone França e Freitas 21 August 2018 (has links)
Orientador: Alexandre Nunes Ponezi / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-21T07:25:38Z (GMT). No. of bitstreams: 1 Torres_DaniladeLeoneFrancaeFreitas_M.pdf: 2036503 bytes, checksum: 068ab775d9c675592e34d0bfdd2ca1e9 (MD5) Previous issue date: 2012 / Resumo: O uso de efluente tratado na agricultura irrigada constitui uma alternativa adequada para a preservação de mananciais, além de ser uma importante fonte de nutrientes. No entanto, os riscos de toxicidade devem ser avaliados. Testes ecotoxicológicos apresentam-se como uma ferramenta apropriada, devido à sensibilidade dos organismos e sua ampla aceitação por órgãos governamentais e científicos. O objetivo do presente estudo foi avaliar a toxicidade aguda na fotobactéria marinha Vibrio fischeri e no microcrustáceo Daphnia similis (CE50) e do potencial citotóxico, genotóxico e mutagênico em Allium cepa (cebola) de um efluente sanitário tratado usado para irrigação. Os ensaios foram realizados no efluente bruto e nos tratados utilizados para irrigação: anaeróbio e pos-tratamento anaeróbio (nitrificado). Os resultados evidenciaram que o efluente bruto, apresentou uma maior variação dos valores de CE50 para ambos os organismos. O efluente anaeróbio apresentou um efeito tóxico agudo maior para V. fischeri que para D. similis. Já o nitrificado (pos-tratamento anaeróbio) apresentou uma toxicidade aguda menor para ambos os organismos testados. Na avaliação das aberrações cromossômicas em A. cepa, os efluentes tratados apresentaram uma redução do potencial citotóxico (p<0,05) em relação ao efluente bruto. Pode-se concluir que os testes escolhidos foram adequados para o monitoramento do efluente. Recomenda-se que o uso de efluente tratado na agricultura seja realizado de forma regrada, atentando para os padrões de Boas Práticas Agrícolas (GAP) e de toxicidade. Além disso, em escala real é necessário um estudo de monitoramento periódico que avalie impactos a longo prazo, incluindo testes de toxicidade crônica / Abstract: The use of the treated effluent in agriculture has proven to be an important alternative, since its preservation of water and its potential as source of nutrients, with low potential for negative impact on the environment. However, toxicity remains an important issue. Ecotoxicological tests are appropriate tools to evaluate the toxicity of effluents. The aim of this study was to evaluate acute toxicity on marine bacteria Vibrio fischeri, on micro crustacean Daphnia similis (EC50) and on Allium cepa (onion) (assessment of cytotoxic, mutagenic and genotoxic potencial) in treated sanitary effluent used for irrigation. We tested the raw effluent, and in its treatments, used for irrigation: anaerobic and anaerobic posttreatment (nitrified). Our results showed that the raw effluent had a greater variation of EC50 for both organisms, due to an intrinsic variability of its composition. The anaerobic effluent had a greater acute toxic effect on V. fischeri than for D. similis. Yet, the nitrified (anaerobic post-treatment stage) showed a lower toxicity for both tested organisms. We found a reduction in the citotoxical potential in A. cepa as compared to the raw efluente. We concluded that the tests chosen were adequate for monitoring the effluent since the organisms showed adequate sensitivity. It is therefore suggested that the use of treated wastewater in agriculture should be standardized, noting Good Agricultural Practices (GAP) and toxicity stardards. Furthermore for larger scale assumption it is necessary a periodic monitoring study to assess long term impacts, including chronic toxicity tests / Mestrado / Saneamento e Ambiente / Mestra em Engenharia Civil
326

Redução da concentração de fenol presente em águas residuárias utilizando sistema anaeróbio-aeróbio : desempenho e toxicidade residual / Phenol concentration reduction in wastewater using anaerobic-aerobic system : performance and residual toxicity

Carvalho, Luciana Vechi de 21 August 2018 (has links)
Orientador: Edson Aparecido Abdul Nour / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-21T10:47:29Z (GMT). No. of bitstreams: 1 Carvalho_LucianaVechide_M.pdf: 1975697 bytes, checksum: c889d2b763a156ae4029456cdc836b88 (MD5) Previous issue date: 2012 / Resumo: A grande utilização de compostos tóxicos e o descarte dos mesmos sem o devido tratamento fizeram com que o ecossistema aquático recebesse grande quantidade de contaminantes, os quais, com o passar do tempo, tendem a estar presentes em maiores concentrações no sedimento dos rios e mananciais que recebem o efluente in natura. O fenol é um dos compostos que tem sido utilizado de forma descontrolada tanto pelas indústrias como também para fins domésticos, aumentando ainda mais a concentração deste nos efluentes sanitários. Desta forma, estudou-se a capacidade de um sistema de tratamento biológico combinado, anaeróbio/aeróbio, em reduzir a concentração de fenol presente em efluentes sanitários. O sistema foi composto por um filtro anaeróbio (FA) seguido por um biofiltro aerado submerso (BAS), monitorado por meio de análises físicas, químicas e ensaios ecotoxicológicos. Para os ensaios ecotoxicológicos foi iniciado o cultivo de dois novos organismos - Chironomus xanthus e Eisenia sp. - viventes no sedimento, para avaliação da resposta de ambos ao fenol, sendo esta a parte dos rios em que há o maior acúmulo de contaminantes Também foi utilizado Daphnia similis. A pesquisa foi realizada em três etapas: Fase de adaptação, com duração de 106 dias, em que o sistema de tratamento recebeu o inóculo de um filtro anaeróbio testado para a remoção de formaldeído; Primeira Fase com a adição de 50 mg L-¹ de fenol, com duração de 207 dias, obtendo eficiências de remoção de fenol próximas a 100% com concentração média de fenol no efluente final de 0,16 mg L-¹ e eficiência de DQO acima de 90% e Segunda fase com duração de 115 dias em que a concentração de fenol aplicada foi gradualmente aumentada até o limite de 150 mg L-¹, determinado pela desestabilização do reator anaeróbio, Foram obtidas eficiências de remoção de fenol de 99,7% e de DQO 95,4% sem reduzir a nitrificação e resultando em um efluente final de acordo com as exigências para o lançamento segundo CONAMA 430/2011. O esgoto bruto contendo fenol foi tóxico para Chironomus xanthus e Daphnia similis com CL(50)/96h 60 mg L-¹ e CE(50)/48h 50 mg L-¹, respectivamente. Para o organismo Eisenia sp., os ensaios indicaram que não ocorreu toxicidade ao fenol. O efluente final tratado pelo sistema biológico combinado não apresentou e não causou toxicidade a nenhum dos organismos testes utilizados, indicando que a sua concepção e proposta de operação produziram um efluente que atende os padrões de lançamento para carga orgânica e fenol, sem prejudicar os índices para o nitrogênio amoniacal / Abstract: The great use of toxic compounds and its dispose without proper treatment, have caused a large concentration of contaminants on the aquatic ecosystem over the time, and the tendency is to be present in higher concentrations in the sediment of rivers and springs that hold the effluent in natura. The phenol, is one of the compounds which has been used in an uncontrolled fashion by both industry and also for domestic purposes, further increasing its concentration in the wastewater. This study shows the ability of a biological treatment system combined anaerobic/aerobic, reducing the concentration of phenol present in wastewater. The system consisted of an Anaerobic Filter (FA) followed by a Submerged Aerated Biofilter (BAS), monitored through physical chemical analysis and ecotoxicological tests. For ecotoxicological tests, the cultivation of two new organisms was started Chironomus xanthus and Eisenia sp. - living in the sediment, to assess the response of both to the phenol, being this the part of the rivers where there is greater accumulation of contaminants, was also used Daphnia similis. The study was performed in three phases: adaptation phase, lasting 106 days, where the Processing System received an inoculum of anaerobic filter, tested for the removal of formaldehyde, First stage with the addition of 50 mg L-¹ phenol, with duration of 207 days, obtaining phenol removal efficiencies close to 100%, with an average of phenol concentration in the final effluent of 0,16 mg L-¹ and efficiency of DQO higher than 90%. Second phase with duration of 115 days , where the phenol concentration applied was gradually increased to the limit of 150 mg L-¹ determined by the destabilization of the anaerobic reactor, were obtained efficiencies in phenol removal of 99.7% and 95.4% of DQO, without reduction the nitrification and resulting in an final effluent according to the requirements for launching as per CONAMA 430/2011. The raw sewage containing phenol was toxic to Chironomus xanthus and Daphnia similis with CL(50)/96h 60 mg L-¹ and CE(50)/48h 50 mg L-¹, respectively. For the organism Eisenia sp., the tests indicated that there was no toxicity to phenol. The final effluent treated by this combined biological system, did not show and did not cause toxicity to any of the test organisms used, thereby indicating that its design and proposed operation, were able to produce an effluent that meets discharge standards for organic load and phenol, while preserving the rates for ammonia nitrogen / Mestrado / Saneamento e Ambiente / Mestra em Engenharia Civil
327

Caracterização de iodo de esgotos de lagoa anaeróbia acondicionado em bags visando a sua disposição : estudo de caso - ETE Pedregulho/SP / Characterization of sewage sludge anaerobic pond paked in bags aimed at its disposal : case study - ETE Pedregulho/SP

Pim, Vanderlei 21 August 2018 (has links)
Orientadores: Edevar Luvizotto Junior, Bruno Coraucci Filho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-21T12:01:23Z (GMT). No. of bitstreams: 1 Pim_Vanderlei_M.pdf: 7573689 bytes, checksum: d7840f9ac209c660c1efa3ccb0efc04f (MD5) Previous issue date: 2012 / Resumo: As preocupações com o adequado destino dos lodos de esgotos fizeram da reciclagem uma alternativa de grande perspectiva de evolução no Brasil. O presente estudo visa avaliar o lodo da lagoa anaeróbia da ETE Pedregulho/SP, operada pela Sabesp, bombeado e acondicionado em bags, em relação a sua qualidade, visando disposição. Foram utilizados 3 bags diferentes e realizadas análises antes, durante e depois do bombeamento, percebendo que, durante o tempo, as permeabilidades dos bags não são constantes e que, houve alterações nas caraterísticas do lodo quando nos bags. Foram removidos 614 m3 de lodo da lagoa anaeróbia, havendo melhora na eficiência da ETE. A retração volumétrica do lodo nos bags permitiu constatar a interferência das chuvas no volume dos bags. Houve também uma avaliação do líquido que percolava dos bags. O lodo foi caracterizado como resíduo Classe II A (não perigoso, não Inerte) pela ABNT NBR 10.004:2002 e considerado possível de ser disposto em aterro sanitário; a técnica da respirometria associado à caracterização pela Resolução CONAMA 375/06 - MMA torna o lodo da lagoa anaeróbia passível de aplicação agrícola e, o atendimento às exigências do Ministério da Agricultura permite buscar o registro, especificação e classificação do lodo como fertilizante, biofertilizante ou condicionador de solo. A remoção teve um custo de R$159,92/m3. Considerando as condições avaliadas nesta pesquisa, conclui-se que a utilização agrícola é a forma mais viável de disposição final de lodo de esgotos / Abstract: Concerns about the appropriate destination of sewage sludge made recycling a great perspective of alternative development in Brazil. The present study aims to evaluate the sludge from the anaerobic pond ETE Pedregulho / SP, operated by Sabesp, pumped and stored in bags, in relation to its quality, aiming to disposal. Three different bags were used and analyzed before, during and after pumping, it was noticed that during the time the permeability of the bags are not constant and there were changes in the characteristics of the sludge when in the bags. 614 m3 of sludge from the anaerobic pond were removed, with an improvement in the efficiency of ETE. The evoluation of volumetric shrinkage of the sludge in bags revealed the interference of rain in the volume of bags. There was an evaluation of liquid that percolated. The waste sludge was characterized as Class II A (non-hazardous, non-Inert) by the ABNT NBR 10.004:2002 and considered possible to be disposed in landfill; the technique of respirometry associated to the characterization by Resolução CONAMA 375/06 - MMA makes the sludge of the anaerobic pond be applied for agricultural purposes compliance with the requirements of the Ministry of Agriculture allows searching the record, specification and classification of the sludge as fertilizer, biofertilizer and soil conditioner. The removal had a cost of R$159,92 / m3. Considering the conditions evaluated in this study, it was concluded that agricultural use is the most viable form of disposal of sewage sludge / Mestrado / Saneamento e Ambiente / Mestre em Engenharia Civil
328

Reator compartimentado anaerobio/aerobio, tratando esgoto sanitario : desempenho e operação / Anaerobic/aerobic Baffled Reactor Treating Sanitary Wastewater: Performance and Operation

Silva, Gustavo Henrique Ribeiro da 21 December 2001 (has links)
Orientador: Edson Aparecido Abdul Nour / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil / Made available in DSpace on 2018-08-03T00:31:08Z (GMT). No. of bitstreams: 1 Silva_GustavoHenriqueRibeiroda_M.pdf: 10901410 bytes, checksum: 214e9f14f9626400264bad3cf93fade5 (MD5) Previous issue date: 2001 / Resumo: No presente trabalho de pesquisa foi estudada uma alternativa de união de processos anaeróbios e aeróbios sob a forma de um reator compartimentado anaeróbio/aeróbio, no tratamento de esgoto sanitário. O reator era composto por quatro câmaras seqüenciais, sendo as três primeiras anaeróbias e a última aeróbia, totalizando um volume aproximado de 2,5 m3. O Iodo gerado pelo reator foi separado em um decantador laminar e recirculado à quarta câmara. O reator, localizado em uma E.T.E. da cidade de Limeira, SP, foi operado durante um período de 444 dias, divido em cinco fases, com tempo de detenção hidráulica (TDH) total variando de 7 a 16 horas, alimentado com esgoto sanitário que havia recebido tratamento preliminar. As cinco fases de operação corresponderam a 10, 16, 12, 8 e 7 horas de TDH. Os valores de pH ao longo de todas as câmaras e decantador, variaram entre 5,7 e 8,3 e o valor médio foi de 6,8, não sendo necessário correção e pH durante o período de estudo. Os melhores valores de remoção de 0805 foram obtidos na Fase 4 (TDH=8 horas), 56,9 a 95,7%. Contudo o teste estatístico de comparação de médias de duas amostras, verificou não. haver diferença significativa entre as fases, exceto Fase 2, ao nível de P=O,05. O desempenho do reator quanto a remoção de DQOtotal e SST foi semelhante ao obtido para 0805, com valores de 31,4 a 95,6 e 21,0 a 97,3%, respectivamente, o mesmo ocorrendo para o teste estatístico realizado. Os valores encontrados para oxigênio dissolvido no interior da câmara 4 (aeróbia) foram satisfatórios na maior parte do tempo, de acordo com os valores citados na literatura, alcançando valor máximo de 4,70 e mínimo de O mg 02.L-1. A presença do decantador laminar foi importante na remoção de sólidos provenientes do reator. Após o 1070 dia de operação, o Iodo de recirculação apresentou uma sedimentabilidade de boa a ótima. A configuração do sistema em estudo, promove adequado tratamento do efluente aplicado aliado a uma produção de Iodo aeróbio de fácil gerenciamento / Abstract: The present research aimed to study an alternative route for union of aerobic and anaerobic processes, through the use of a baffled reactor, treating sanitary wastewater. The reactor is composed of four sequential chambers, being the first tree anaerobic chambers and the last one aerobic, composing a total volume of approximately 2.5 m3. The sludge generated in the reactor is separated in a laminar sedimentation tank and recycled into the forth chamber. The reactor - placed in a wastewater treating plan of Limeira city, S. P., 8razil -operated in a period of 444 days. This period was divided in five phases, with hydraulic detention times (HOT) varying from 7 to 16 hours. The reactor was fed with sanitary wastewater which had already suffered a preliminary treatment. The five phases of operation corresponded to 10, 16, 12,8 e 7 hours of HOT, respectively. The pH values in all chambers and in the sedimentation tank, varied between 5,7 e 8,3, with a mean value of 6,8; the correction of pH values was not necessary during all periods. The best value of 8005 removal was attained in the Phase 4 (HOT=8 hours), 56,9 to 95,7%. However, the statistic comparison of the means .of two samples showed that there was no significant difference between the phases, except in Phase 2, with P=0,05. The reactor performance, in relation to COOtotal removal and TSS, was similar to that obtained for the 8005, with values of 31,4 to 95,6 and 21,0 to 97,3%, respectively. The same occurred in the statistic test. In chamber 4, the oxygen dissolved values were satisfactory in most of the periods, reaching the maximum of 4,7 and of 0,0 mg 02.L-1. The laminar sedimentation tank was important for removal of solids produced in the sedimentation tank. After the 10ih operation day, the recycled sludge presented a sedimentation capability classified between good and very good. Thus, It is possible to affirm that the baffled reactor configuration of the present work promotes an useful effluent treatment, employed to the production of an aerobic sludge with easy management / Mestrado / Saneamento e Ambiente / Mestre em Engenharia Civil
329

A situação brasileira dos biossolidos

Machado, Maria Fernanda de Sousa 13 July 2001 (has links)
Orientador : Roberto Feijo de Figueiredo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil / Made available in DSpace on 2018-08-03T03:55:24Z (GMT). No. of bitstreams: 1 Machado_MariaFernandadeSousa_M.pdf: 10713217 bytes, checksum: 6261d27597e776e395189569e356f882 (MD5) Previous issue date: 2001 / Resumo: Os processos de tratamento de esgoto geram diversos subprodutos, dentre eles o lodo, que é responsável por um elevado custo operacional em seu tratamento, transporte e disposição final. Biossólidos é um novo termo designado para o lodo estabilizado, gerado nas estações de tratamento de esgoto que possa ser recic1ado, recebendo assim um destino final mais útil, como por exemplo a aplicação no solo para fins agrícolas. Visando estas novas potencialidades do lodo de esgoto, este estudo apresenta um diagnóstico da situação brasileira dos biossólidos, abordando a sua produção real e teórica, o destino final e a sua constituição, além de informações referentes ao tratamento de esgoto no Brasil. A metodologia desta pesquisa consistiu na elaboração de um formulário enviado às prestadoras de serviços de saneamento responsáveis pelas estações de tratamento de esgoto, com questões relacionadas ao lodo e ao tratamento de esgoto. Foram coletados os dados provenientes de 275 estações, que são responsáveis pelo tratamento de 1.877.618,25 m3/dia de esgoto, atendendo a 12.777.974 pessoas, e produzindo teoricamente 151.724,50 toneladas/ano de lodo seco. As informações referentes à produção real e à constituição dos biossólidos são bastante escassas, pois, a maioria das operadoras de tratamento de esgoto não produzem as informações referentes ao lodo de forma sistemática, dando enfoque somente ao esgoto tratado, o que revela a necessidade urgente de investimentos nesse setor / Abstract: The wastewater treatment process generate several subproducts, one of them is the sewage sludge, which has a higher operational cost of treatment, transportation and final disposal.Biosolids is a new word assigned to the stabilized sludge generated in the wastewater treatment plants, in order to be recyc1ed, having a more useful final disposal, such as applying to agricultural land. Visualizing these new potential uses of sewage sludge, this study presents a diagnostic of the Brazilian situation of biossolids, approaching its real and theoretical production, final disposal and constituents, as well as information related to wastewater treatment in Brazil. The methodology used in this research consisted on the elaboration of a questionaire sent to the companies suppliers of sanitation services which are responsible for wastewater treatment plants, with questions related to sludge and sewage treatment. There was collected data answered by 275 wastewater treatment plants, which are responsible for the treatment of 1,877,618,25 m3/day of wastewater, providing this service to 12,777,974 inhabitants and producing theoretically 151,724.50 tons/year of dried sludge. The information regarding the real production and constitution of the biosolids are very scant, because most of the wastewater treatment companies do not report enough information regarding the sludge in a systematic manner, reporting only data about the treated sludge, disc1osing a urgent need of investments in this sector / Mestrado / Saneamento e Ambiente / Mestre em Engenharia Civil
330

Estudo da absorção de metais em cultura de milho irrigado com efluente de esgoto domestico empregando a reflexão total com radiação sincroton (SR-TXRF)

Vieira, Claudia Brasil 19 February 2004 (has links)
Orientador: Silvana Moreira / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-04T00:14:42Z (GMT). No. of bitstreams: 1 Vieira_ClaudiaBrasil_D.pdf: 5833113 bytes, checksum: 31e0a6b8102959812d7979ce28eac381 (MD5) Previous issue date: 2004 / Resumo: O uso de efluente secundário de esgoto doméstico na agricultura tem evoluído significativamente nas últimas décadas. Sob as condições do nosso país, é promissor a utilização de efluentes de esgotos domésticos, visando à reutilização dos nutrientes originários da ecomposição da matéria orgânica. A aplicação do método de irrigação que utiliza a técnica de infiltração por sulcos rasos como pós-tratamento dos efluentes de filtros anaeróbios pode ser utilizada em diferentes culturas, aliando os critérios da Engenharia Sanitária aos da Engenharia de Irrigação. Para tanto, o monitoramento e o controle ambiental exigem técnicas analíticas capazes de determinar vários elementos, entre eles os metais são de particular nteresse, visto que estes têm efeitos tóxicos nos seres vivos. Desta forma, o objetivo principal deste trabalho foi avaliar a absorção de metais rovenientes do esgoto doméstico aplicado através de um sistema de irrigação por sulcos. Para isto a cultura de milho (AG 405-AGROCERES) foi submetida a dois diferentes tratamentos: irrigação com efluente de esgoto doméstico e com água. Após o crescimento vegetativo as plantas coletadas foram divididas em duas partes: grãos e folhas. Estas diferentes partes foram submetidas a procedimento de digestão em sistema aberto e a seguir analisadas por Fluorescência de Raios X por Reflexão Total com Radiação Síncrotron (SR-TXRF). Foi observado que a concentração de metais nas plantas submetidas à aplicação com efluente foi mais elevada do que nas plantas irrigadas com água. Os resultados indicaram que a absorção de metais, nas folhas e na espiga, está diretamente relacionada com a taxa de aplicação no caso da irrigação com água. Mas no caso da irrigação com efluente foi observada uma maior absorção de metais quando a planta foi irrigada com a taxa de aplicação de 180 L, tanto para as folhas como para a espiga / Doutorado / Recursos Hidricos / Mestre em Engenharia Civil

Page generated in 0.0557 seconds