• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 56
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 58
  • 27
  • 19
  • 15
  • 15
  • 15
  • 12
  • 9
  • 9
  • 9
  • 7
  • 6
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Utilização de um framework PCI Express® em um espectrômetro digital de ressonância magnética / Utilization of a PCI Express® framework in a digital magnetic resonance spectrometer

Martins, Tiago Amaro 23 June 2017 (has links)
O foco central desse trabalho é a utilização e aprimoramento de um framework Peripheral Component Interconnect Express (PCI Express®) para a comunicação de dados em um Espectrômetro Digital de Ressonância Magnética (Digital Magnetic Resonance Spectrometer – DMRS) utilizando o conceito de Field-Programmable Gate Array (FPGA). Esse trabalho foi desenvolvido para servir como base de comunicação para o Espectrômetro Digital de Ressonância Magnética do Centro de Imagens e Espectroscopia in vivo por Ressonância Magnética (CIERMag) devido ao requerimento de altas taxas de transferência dos dados adquiridos. A integração dessa nova comunicação, entre o software e o hardware do espectrômetro, mantém compatibilidade com as interfaces já existentes possibilitando a execução de todas as sequências desenvolvidas sem nenhuma alteração. A incorporação da comunicação PCI Express provê uma solução com um número menor de etapas por transferência em comparação com a comunicação Ethernet. Com isso é possível aumentar o desempenho do sistema e obter taxas de transferência mais elevadas. Para isso, foram feitas mudanças no hardware de forma a torná-lo mais eficiente, reduzindo o número de ciclos de clock por operação e também a quantidade de lógica sintetizada. Além disso, a latência do software durante as transferências também foi reduzida através da utilização de interrupções Message Signaled Interrupt (MSI) e do método Scatter and Gather usado para reduzir a quantidade de cópias de dados na memória principal do computador. Dessa forma, obteve-se, como resultados reais, uma taxa de transferência efetiva (throughput) de 97% do valor máximo da banda possível do barramento PCI Express. / The central focus of this work is the implementation and use of a Peripheral Component Interconnect Express (PCI Express®) framework for data communication on a Digital Magnetic Resonance Spectrometer (DMRS) using the concept of Field-Programmable Gate Array (FPGA). This work is being developed to serve as a communication basis for the magnetic resonance Digital Spectrometer of the Centro de Imagens e Espectroscopia in vivo por Ressonância Magnética (CIERMag) due to demand of high transfer rates of acquired data. The integration of this new communication, between spectrometer software and hardware, keeps compatibility with existing interfaces, making it possible to execute all developed magnetic resonance sequences without any change. The incorporation of PCI Express communication provides solution with a lower number of steps per transfer when compared to Ethernet communication. By this means it\'s possible to increase system performance and, as result, have higher transfer rates. To accomplish that, the number of clock cycles per operation was reduced, so was the synthesized logic. Furthermore, software latency for data transfer was also reduced consequence of MSI interruption implementation and the use of Scatter and Gather method to remove data movement across the computer main memory. Therefore, it was obtained, as measured real result, a throughput value of 97% the theoretical maximum value for the hardware.
22

PyMR: a framework for programming magnetic resonance systems / PyMR: Um framework para programação de sistemas de ressonância magnética

Pizetta, Daniel Cosmo 04 December 2018 (has links)
In recent years, the use of magnetic resonance technology has grown with advances in hardware, delivering accessible and small-size equipment and devices that open a range of new applications. Innovation in this field requires versatility and flexibility of both hardware and software. Despite the technological advances in the magnetic resonance hardware, the software still the most notable problem currently. This stagnation, delays progress that could reduce production costs and deliver faster development. Researchers in this field are unsatisfied with currently available options. In this panorama, we seek the enhancement of our specific framework for programming magnetic resonance systems, employing concepts from the areas of computing, engineering, and physics. This setup allows the software to merge different perceptions, causing it to be flexible and robust. We converged to Python and object-oriented programming to offer the Python Magnetic Resonance framework - PyMR. The PyMR includes graphical interfaces from templates that can be filled with data, requiring no programming. Our framework comprises other programming tools such as our plugin for the Spyder IDE, which creates the perfect environment to create systems and the pulse sequences. Also, a user-friendly magnetic resonance simulator MR SPRINT, derived from the PyMR structure, addresses educational use, exposing the whole experiment construction, setup, and visualization. Including, PyMR has been contributing to new challenging magnetic resonance systems, introducing modern concepts to change the actual scenario the researchers are facing when developing new magnetic resonance systems. / Nos últimos anos, o uso da tecnologia de ressonância magnética cresceu com os avanços em hardware, fornecendo equipamentos e dispositivos acessíveis e de pequeno porte que abrem uma série de novas aplicações. Inovações neste campo requerem versatilidade e flexibilidade de hardware e software. Apesar dos avanços tecnológicos no hardware de ressonância magnética, o software ainda é um dos maiores problemas atualmente. Essa estagnação atrasa o progresso que poderia reduzir os custos de produção e proporcionar um desenvolvimento mais rápido. Além disso, pesquisadores neste campo estão insatisfeitos com as opções atualmente disponíveis. Com este panorama, buscamos o aprimoramento de nosso framework para programação de sistemas de ressonância magnética, empregando conceitos das áreas de computação, engenharia e física. Essa configuração permite que o software mescle visões de diferentes meios, fazendo com que a estrutura seja flexível e robusta. Nós convergimos, então, para a linguagem Python e programação orientada a objetos para oferecer o framework Python Magnetic Resonance - PyMR. O PyMR inclui interfaces gráficas a partir de modelos que podem ser preenchidos com dados, sem a necessidade de programação. Nossa estrutura compreende outras ferramentas de programação, como o nosso plugin para o Spyder IDE, que cria o ambiente perfeito para criar novos sistemas e sequências de pulsos. Além disso, um simulador de ressonância magnética de fácil utilização, MR SPRINT, derivado da estrutura PyMR, aborda o uso educacional, expondo toda a construção, configuração e visualização do experimento. O PyMR vem contribuindo para novos e desafiadores sistemas de ressonância magnética, introduzindo conceitos modernos para mudar o cenário atual que os pesquisadores estão enfrentando.
23

UM ESPECTROMETRO \"MINI-ORANGE\" PARA ELECTRONS / A mini-orange spectrometer for electrons

Silva, Nelson Canzian da 04 May 1990 (has links)
Foi projetado e construído um espectrômetro Mini-Orange (MO) para eléctrons, utilizando imãs planos permanentes e um detector de barreira de superfície. Foram determinadas as funções de transmissão de diferentes configurações do sistema, para energias entre 200-1100 keV. Foi desenvolvido um modelo matemático do sistema, a partir de solução analítica para o campo de um imã plano e da integração numérica da equação de movimento dos eléctrons no campo de MO. As funções de transmissão assim obtidas foram comparadas aos resultados experimentais e mostraram um bom acordo para energias baixas e intermediárias. / A Mini-Orange spectrometer for electrons was designed and built, using plane permanent magnets and a surface barrier detector. Transmission functions were obtained for various system configurations and for energies between 200-1100 keV. A mathematical model of the system was developed, using the analytical solution for the field of a plane magnet and the numerical integration of the equation of motion of the electrons in the MO magnetic field. The calculated transmission functions were compared to the experimental data, showing a good agreement for low and intermediate energies.
24

Inseticidas piretróides do desenvolvimento analítico ao nível de resíduos em alimentos de origem animal

Dallegrave, Alexsandro January 2017 (has links)
O uso de inseticidas piretróides na agricultura, pecuária e em áreas urbanas pode gerar problemas à saúde dos seres humanos e dos animais. O controle destes inseticidas nos alimentos é uma importante ferramenta para avaliar o risco da exposição a estes compostos. Em vista disso, este estudo tem por objetivo desenvolver um método analítico eficiente, sensível e confiável para o preparo das amostras e quantificação de ultra traços de 17 piretróides e um organofosforado, o clorpirifós, utilizando padrões marcados além de realizar uma discussão sobre a incidência destes inseticidas. Os alimentos de origem animal selecionados para este estudo são: músculo bovino, peixe e de frango, leite e ovos. São alimentos ricos em gordura, devido a isso, são candidatos a estarem contaminados com estes inseticidas que apresentam propriedades lipofílicas. O preparo da amostra consistiu na liofilização, extração assistida por ultrassom com solvente orgânico e clean up utilizando cartuchos de SPE com fases C18 e alumina básica. A técnica instrumental utilizada foi a cromatografia a gás acoplada a espectrometria de massa no modo tandem utilizando ionização química no modo negativo (GC/NCI-MS/MS). As recuperações obtidas foram entre 50 e 120% para a maioria dos inseticidas com uma média de desvio padrão relativa abaixo de 10%. Na análise do perfil isomérico dos resultados de recuperação houve predominância dos isômeros na forma cis perante a trans. No quesito sensibilidade, os limites de detecção atingiram valores de 0,06 a 101 ng kg-1. O método desenvolvido foi utilizado para analisar 152 amostras, sendo que destas, apenas 4 não apresentaram nível de contaminação por inseticidas piretróides ou clorpirifós. A maioria estava contaminada com pelo menos 2 a 3 destes inseticidas. Os inseticidas detectados foram a bifentrina, cipermetrina, cialotrina, permetrina, deltametrina e o clorpirifós. Cabe ressaltar que apenas uma amostra de leite estava contaminada com níveis de clorpirifós acima do permitido. Na estimativa da ingestão diária, nenhum dos inseticidas ultrapassou os limites de segurança aceitáveis. Houve um maior nível de correlação entre a quantidade de inseticida e o teor de lipídios nas amostras de músculo bovino, de peixe e de frango. Nas amostras segregadas de ovos, os inseticidas estavam concentrados na gema. Os fatores isoméricos calculados nas amostras positivas apresentaram valores diferentes dos fatores isoméricos dos padrões e dos produtos comerciais. Houve uma predominância dos isômeros cis para a cipermetrina e um predomínio do segundo isômero (λ-cialotrina), no caso da cialotrina. / The use of pyrethroid insecticides in agriculture, livestock and in urban areas can lead to problems for the health of humans and animals. The control of these insecticides in food is an important tool to control the risk of exposure to these compounds. Therefore, the objective of this study was to develop an efficient, sensitive and reliable analytical method to promote the sample preparation and analysis of 17 pyrethroids and one organophosphorus, chlorpyrifos, using labelled standards and to discuss the incidence of these insecticides. The foods selected for this study are of animal origin, they are beef, fish, chicken, milk and eggs. They are foods rich in fat, in view of that, are candidates to be contaminated with these insecticides that have lipophilic properties. The proposed sample preparation method was based on freeze-dried samples, solvent extraction and clean up using SPE cartridges with C18 and basic alumina phases. The instrumental technique used was gas chromatography coupled to mass spectrometry in tandem, with negative chemical ionization (GC/NCI-MS/MS). Recoveries in the range of 50 and 120% were obtained with a mean relative standard deviation below 10%. In the analysis of the isomeric profile of the recovery results there was predominance of the isomers in the form cis. In the sensitivity question, detection limits reached values of 0.06 to 101 ng kg-1. The method developed was used to analyze 152 samples, of which only 4 did not present any level of contamination with pyrethroids or chlorpyrifos insecticides. Most were contaminated with at least 2 to 3 of these insecticides. The insecticides detected were bifenthrin, cypermethrin, cyhalothrin, permethrin, deltamethrin and chlorpyrifos. It is important to mention that only one milk sample was contaminated with chlorpyrifos levels above that allowed. In the estimation of daily intake, none of the insecticides exceeded the safety limits of acceptable daily intake. There was a strong correlation between the amount of insecticide and the lipid content in bovine muscle, fish and chicken samples. In the eggs segregated samples the insecticides were concentrated in the yolk. The calculated isomeric factors in the positive samples presented different values of the isomeric factors of the commercial products and standard. There was a predominance of the cis isomers for cypermethrin and a predominance of the second (λ-cyhalothrin) isomer in the case of cyhalothrin.
25

Obtenção e caracterização cromatográfica de bio-óleos de bagaço de cana de açúcar por pirólise convencional e catalítica, empregando reatores de leito fixo

Diedoviec, Eduardo January 2016 (has links)
São apresentados os rendimentos mássicos dos produtos: líquido, sólido e gasoso, de pirólises intermediárias de bagaço de cana de açúcar em reatores de leito fixo, sendo os bio-óleos caracterizados via GC/qMS para fins de comparação de resultados. Um novo design de reator propiciou uma taxa de transferência de calor maior do que a de um reator pré-existente, levando a um menor rendimento em biocarvão e maior percentual de área cromatográfica de furanos no bio-óleo obtido. Em ambos os reatores, ocorreu a produção de 5-hidroximetilfurfural (5-HMF, 11,69 e 14,85%, para reator convencional e novo, respectivamente), cuja produção seletiva é de interesse econômico. Cinco catalisadores foram empregados em pirólises de bagaço de cana de açúcar, no reator novo: CaO, ZnO, CuCl2, NiCl2 e nanopartículas de ouro. O CaO aumentou a área cromatográfica percentual de compostos fenólicos, enquanto que o ZnO aumentou a produção de 2,3-di-hidro-benzofurano (20,87%) e as nanopartículas de ouro propiciaram uma maior produção de 5-HMF (17,41%). O uso dos catalisadores CuCl2 e NiCl2 levaram a um aumento da área percentual de compostos fenólicos sem outros grupamentos químicos em suas estruturas moleculares, bem como a uma diminuição na área dos furanos. / Liquid, solid and gas mass yields of intermediate pyrolyses of sugar cane bagasse in fixed bed reactors are reported and characterization of bio-oils through via GC/qMS was performed for the purpose of comparison among results. A new design of reactor is proposed, where the heat transfer rate is higher than the one of a pre-existing reactor, leading to less biochar production and to a higher chromatographic percentage area of furanes in the bio-oils. The production of 5-hydroxy-methyl-furfural (5-HMF), which is an economically interesting compound, occurred in both reactors (11.69 e 14.85%, to conventional and new reactor, respectively). Five catalysts were employed in the pyrolysis of sugar cane bagasse in the new designed reactor: CaO, ZnO, CuCl2, NiCl2, and nanoparticles of gold. Calcium oxide provided an enhancement in the chromagraphic area percent of phenolic compounds, ZnO improved the production of 2,3-dihydro benzofurane (20.87%), while nanoparticles of gold provided a higher production of 5-HMF (17.41%). The use of CuCl2 and NiCl2 lead to a higher percentage of phenolic compounds with no other chemical groups in their chemical structure, while the percentage of furanes was lowered.
26

Espectroscopia do núcleo 23Mg acima do limiar de decaimento de prótons com interesse para astrofísica nuclear / Spectroscopy of 23Mg nucleus above the proton threshold of interest to nuclear astrophysics

Lara, Alessandro Luiz de 05 November 2018 (has links)
O conhecimento das reações nucleares que ocorrem no interior das estrelas permite estudar como será a evolução destes astros e as relações de abundância entre os isótopos de alguns elementos. Em alguns casos, a detecção de elementos traços pode ser útil para inferir a ocorrência de eventos explosivos, como novas e supernovas. Um destes elementos é o 22Na, cuja abundância depende da reação de captura de próton 22Na(p, ?)23Mg. Assim, o estudo dos estados de ressonância do 23Mg, é importante para compreender o mecanismo de reação e determinar a abundância do 22Na. O núcleo de 23Mg ainda participa do ciclo NeNa na fase AGB da evolução de estrelas de massa média. Com essa motivação propomos o estudo espectroscópico do núcleo 23Mg por meio da reação de transferência 24Mg(3He, 4He)23Mg, cujos dados experimentais foram obtidos no laboratório Tandem-Orsay (França), com o uso de um feixe de 3He de 25 MeV. As ressonâncias de interesse do núcleo 23Mg estudadas nesse trabalho estão compreendidas na faixa de energia de excitação 7.5 MeV a 9.5 MeV. Os estados de ressonância do 23Mg foram populados com a interação do feixe com o alvo de natMg, e as partículas de 4He foram analisadas com o espectrógrafo Split-pole. Os espectros de posição das partículas de 4He foram então calibrados em rigidez magnética, por meio de um polinômio de segunda ordem. Após a calibração os espectros de rigidez magnética foram transformados em espectros de energia de excitação. Nesses espectros pudemos identificar e estudar a presença de contaminantes. Vários estados abaixo e alguns estados acima do limiar de decaimento foram observados e identificados. Dentre os estados acima do limiar estão os estados: 7.586, 7.648, (7.782 e 7.786), 7.855, 8.076, 8.163, 8.420, 8.453, 8.943 e 8.990 MeV do 23Mg. Sendo que apenas os estados 7.586 e 8.163 tem o spin J=5/2+ estabelecido. Ao final apresentamos uma discussã / The knowledge of the nuclear reactions that take place inside the stars allows to study how the evolution of this star will be and the relations of abundance between the isotopes of some elements. In some cases the detection of trace elements can be useful to infer about the occurrence of explosive events, as novae and the supernovae. One of these elements is the 22Na, whose abundance depends on the proton capture reaction 22Na(p, ?)23Mg. The gamma radiation photon with energy 1.275 MeV emitted by 22Na may be a novae type event indicator. Thus, the study of the resonance states of 23Mg is important to understand the mechanism of reaction and determine the 22Na abundance. The nucleus of 23Mg still participate in the cycle NeNa in the AGB phase of the evolution of average stars. With this motivation, we propose to study the spectroscopy of the 23Mg by the 24Mg(3He, 4He)23Mg neutron transfer reaction, whose experimental data were obtained in the Tandem-Orsay facility (France), using the 3He beam of energy 25 MeV. The resonances of interest for this work are in the range of 7.5 MeV up to 9.5 MeV, above the decay threshold for protons. The resonance states of 23Mg were obtained with the interaction of the beam with the natMg target, and the 4He particles were analyzed in a Split-pole spectrograph. The position spectra were then calibrated in magnetic rigidity by means of a second-order polynomial function. The effects of the contaminants were analyzed by converting the spectra into excitation energy, in which it was possible to separate the states 7.586, 7.648, (7.782 e 7.786), 7.855, 8.076, 8.163, 8.420, 8.453, 8.943 e 8.990 MeV of 23Mg. Finally we present a qualitative discussion of the angular distribution for some states and we discuss the possibilities for the future.
27

Espectropolarimetro computadorizado : nova maneira de obtenção da atividade ótica / Computerized spectrometer: a new way to obtain optical activity data

Melo, Washington Luiz de Barros 23 May 1985 (has links)
Montamos um espectrômetro o qual nos permite obter dados de atividade ótica Dispersão Rotatória (DRO) e Dicroísmo Circular (DC) simultaneamente. O sistema ótico consiste de uma fonte de luz, um monocromador, um suporte para amostra, um analisador gigante e um detector de luz. O analisador girante é sustentado por um mancal pneumático e gira usando um motor de passo, o qual é controlado por um microcomputador. Um outro motor de passo também controlado por microcomputador é usado para girar a grade de difração do monocromador. Para obter os espectros de DRO e DC, o monocromador pára em um certo comprimento de onda, enquanto o eixo de transmissão do analisador é posicionado em &#946= 0&#176, 45&#176, 90&#176 e -45&#176 relativo ao eixo de transmissão do polarizador. O microcomputador através do detector de luz lê as quatro intensidades de luz e usando um formalismo desenvolvido por nós, relaciona-as à elipticidade e a rotação ótica naquele comprimento de onda. O monocromador é então girado a um novo comprimento de onda e o procedimento é repetido. No final, os espectros de DC e DRO podem ser mostrados em uma Tabela ou com um Gráfico. Além de funcionar como um espectropolarímetro, o equipamento pode ser usado também como um espectrofotômetro, para acompanhar cinética de reação, para medir dicroísmo linear, etc... Devido à relação sinal/ruído, temos nos ângulos medidos, uma resolução de 1&#186 / We have assembled a spectrometer which provides the optical activity data Optical Rotatory Dispersion (ORD) and Circular Dichroism (CD) simultaneously. The Optical System consists of a source of light, a monochromator, a polarizer, a sample holder, a rotating analyzer and a light detector. The rotating analyzer is supported by a pneumatic bearing and rotates using a step motor which is controlled by a microcomputer. Another spet motor also controlled by the microcomputer is used to rotate the diffraction grating of the monochromator. To obtain the ORD and CD spectra, the monochromator stops at a certain wave length, while the transmission axis of the analyzer is positioned at &#946= 0&#176, 45&#176, 90&#176 e -45&#176 relative to the transmission axis of the polarizer. The microcomputer through the light detector reads the four light intensities and using the formalism developed by us relates them to the elipticity and optical rotation at that wavelength. The monochromator is then rotated to a new wavelength and the procedure is repeated. At the end the CD and ORD spectra can be shown in a Table or as a graph. Besides functioning as a spectropolarimeter, the equipment can be use also as a regular spectrometer, to follow kinetic of recreations, to measure linear dichroism, etc Due to the signal/noise ratio we have in the measured angles a resolution of 1&#176
28

\"Implementação da técnica de correlações angulares perturbadas no laboratório Pelletron para estudo de estruturas e interações de biomoléculas\" / Implementation of The Perturbed Angular Correlations Technique at The Pelletron Laboratory for the Study of Biomolecules Structures and Interactions

Jairo Cavalcante de Souza 13 February 2007 (has links)
Este trabalho de mestrado trata da implementação de um espectrômetro de correlações angulares perturbadas no Laboratório do Acelerador Pelletron do Instituto de Física da Universidade de São Paulo. O espectrômetro é formado por seis detectores cintiladores com cristais de \'BaF IND.2\', de 3 polegadas de diâmetro por 6 de comprimento, com um sistema eletrônico e de aquisição de dados multiparamétrico padrão CAMAC. Diferentemente do usual, os espectros de energia dos raios gama dos núcleos de prova são adquiridos para cada detector, o que permite manter um controle maior sobre todo o experimento. Além disso, um mesmo experimento pode ser revisto com diferentes abordagens por diversas vezes, pois todas as informações sobre ele são armazenadas. Com a configuração eletrônica adotada, os espectros de energia são obtidos por meio de um QDC (charge to digital converter), dispensando o uso de pré-amplificadores. Os espectros de tempo são adquiridos com um TDC (time do digital converter). A seleção dos eventos de coincidência é realizada computacionalmente, procedimento que pode ser realizado durante a aquisição dos dados. Como a motivação para a implementação desse espectrômetro é o estudo de estruturas e interações de biomoléculas por meio da técnica de correlações angulares (PAC), foram realizadas medidas exploratórias, com o uso do espectrômetro do Laboratório de interações Hiperfinas (LIH) do Centro do Reator de Pesquisas (CRPq) no IPEN, paralelamente à implementação do espectrômetro. As primeiras medições foram realizadas com amostras de vesículas lipídicas. Com essas medidas foi possível notar a influência da variação de tamanho das moléculas (diminuição de tamanho em uma ordem de grandeza) no tempo de correlação rotacional à temperatura ambiente, quando adicionado SDS (sodium dodecyl sulfate) na suspensão para formação de um agregado micelar. As duas séries de medidas seguintes foram realizadas com amostras de SDS nas quais variaram-se as concentrações para se tentar verificar alterações na geometria ou na mobilidade das moléculas em função desse parâmetro. Foi possível notar que o comportamento das funções perturbação experimentais variaram com as amostras, porém não foi possível notar sistemática no comportamtento. Outro fator notado foi a influência do meio. O comportamento das moléculas quando na presença de metanol nas amostras era bem diferente das soluções aquosas. Também não foi possível obter uma conclusão clara quanto à concentração micelar crítica para soluções aquosas. Por fim foram realizadas medidas com amostras de proteína calmodulina. Foram feitas medidas à temperatura ambiente e a 77K. Notou-se que essa proteína é passível de ser estudada por meio da técnica PAC. Para confirmar a presença da proteína nas amostras e também tentar verificar um deslocamento na massa devido à presença do íon \'ANTPOT.111 Cd\' \'ANTPOT.2+\' foram realizadas medidas de espectrometria de massas no Laboratório de Espectrometria de Massas na Embrapa em Brasília. Foi possível confirmar a presença da proteína nas amostras, porém não foi possível notar a presença de \'ANTPOT.111 Cd\' devido à baixa concentração de íons utilizados com a técnica PAC. / This work is related to the implementation of a perturbed angular correlation (PAC) spectrometer at the University of São Paulo Pelletron Laboratory. The spectrometer consists of 6 cylindrical BaF$_2$ scintillator detectors, with 3 inches diameter and 6 inches length and a multiparameter CAMAC data acquisition system. Different from usual, the gamma ray energy spectra of the cascade nuclei are acquired for each detector, which allows us to have more control of the experiment. Besides, the same experiment can be revised with different approaches at any time. With the adopted electronics configuration, the energy spectra are obtained through a QDC (charge to digital converter) module, which dispenses the use of pre-amplifiers. The time spectra are acquired with a TDC (time to digital converter) module. The selection of coincidence events is performed computationally, and this procedure can be evaluated during the data acquisition. The main motivation for implementing this spectrometer is the study of the structure and interactions of biomolecules through the perturbed angular correlation technique. Test measurements were performed, parallel to the spectrometer construction, with the use of the Hyperfine Interactions Laboratory spectrometer at the Centro do Reator de Pesquisas do Instituto de Pesquisas Energéticas e Nucleares (CRPq-IPEN). The first measurements were performed with lipidic vesicles samples. In this case it was possible to observe the influence of the molecule dimension change (decrease in one order) on the rotational correlation time at room temperature, when SDS (sodium dodecyl sulfate) was added in the suspension to form micellar aggregation. The two following series of measurements were performed with SDS samples in which the concentration was varied in order to verify modifications in the geometry or mobility of the molecules as a function of that parameter. The behavior of the experimental perturbation functions varied with the samples. However, it was not possible to point out any systematics in their behavior. The molecules behavior when in presence of methanol in the samples was very different from the aqueous solutions. Also, it was not possible to obtain a clear conclusion about the critical micellar concentration for the aqueous solutions. Finally, the last measurements were performed with calmodulin protein samples, at room temperature and at 77K. In this case we concluded that this protein can be studied through the PAC technique. In order to confirm the presence of the protein in the samples and at same time to verify if any mass displacement occurred due to the presence of the $^{111}$Cd$^{2+}$, mass spectrometry measurements were performed at the Laboratório de Espectrometria de Massas -- Embrapa in Brasília. It was possible to confirm the presence of the protein in the samples, but it was not possible to observe the mass displacement due to the presence of the $^{111}$Cd, since the ions concentration used with the PAC technique is very low.
29

Caracterização de bio-óleo da pirólise da palha de cana de açúcar usando fracionamento em sistema pressurizado e cromatografia gasosa mono e bidimensional com detector de espectrometria de massas com analisador quadrupolar

Cunha, Michele Espinosa da January 2013 (has links)
Este trabalho descreve a utilização de GC×GC/qMS para a caracterização de bio-óleo obtido a partir da pirólise de palha de cana-de-açúcar e de suas frações resultantes do fracionamento usando solventes pressurizados. É o primeiro uso desta técnica com analisador quadrupolar para a caracterização de bio-óleo. A GC×GC/qMS aliada a algumas ferramentas computacionais, permitiu a identificação e classificação dos compostos de acordo com diversos fatores como a classe química, o número de átomos de carbono, o número de substituintes na cadeia carbônica, o massa molecular e os picos principais no espectro de massas. Utilizou-se também o sistema de LTPRI (índice de retenção linear com temperatura programada) para a confirmação da identificação de alguns dos compostos no bio-óleo e nas frações. Verificou-se um número total de 331 compostos tentativamente identificados no bio-óleo bruto e destes 166 foram confirmados por identificação LTPRI, em sua maioria compostos polares. A análise quantitativa comprovou que o bio-óleo de palha de cana-de-açúcar estudado é composto majoritariamente por fenóis (2-metilfenol, 3,4-dimetilfenol e 4-metilcatecol), além de aldeidos (4-hidróxibenzaldeído e siringaldeído), os quais após o fracionamento puderam ter suas concentrações determinadas na amostra de forma inequívoca pela técnica de cromatografia gasosa. O passo de fracionamento promoveu uma melhor seletividade dos compostos nas frações, permitindo a identificação de um maior número de compostos, assim como suas quantificações. / This work describes the use of GC×GC/qMS for the characterization of bio-oil from the pyrolysis of sugar cane straw and its fractions using pressurized solvent fractionation. This is the first use of this technique for a bio-oil characterization. The GC×GC/qMS allied to some computational tools, allowed the identification and classification of the compounds according manyfactors as chemical class, number of carbons, number of substituents in the carbonic side chain, molecular weight and main peaks in the mass fragmentation spectra. It was used also the LTPRI (linear-temperature-programmed retention index) system for the confirmation of identification of some of the compounds in the bio-oil and fractions. It was found a total number of 331 compounds tentatively identified in the crude bio-oil and 166 were confirmed by LTPRI identification, mostly polar compounds. The quantitative analysis showed that the bio-oil of sugar cane straw is composed mainly by phenols (Phenol, 2-methyl, Phenol, 3,4-dimethyl and Catechol, 4-methyl) and also by the aldehydes Benzaldehyde (4-hydroxy and Syringaldehyde), which after fractionation might have their concentrations determined in the sample so unequivocal by gas chromatography. The step of fractionation stimulated a better selectivity of the compounds in the fractions, permitting the identification of a larger number of compounds, as well as their concentrations.
30

Dosimetria de nêutrons / Neutron dosimetry

Fratin, Luciano 20 September 1993 (has links)
Instalações para irradiação com nêutrons foram projetadas e construídas, visando o estabelecimento de procedimentos de calibração de monitores e dosímetros de nêutrons. Uma fonte calibrada de ANTPOT.241 AmBe com atividade de ANTPOT.185 GBq, garantiu rastreabilidade às medidas realizadas, e possibilitou irradiações com taxas de dose que variaram entre 9 nSv s POT.-1 e 0,5 muuSv s POT.-1. No arranjo elaborado para irradiações com nêutrons térmicos, com fluxo calibrado, a taxa de dose utilizada foi 50 nSv s POT.-1. A calibração de um espectrômetro de esferas de Bonner permitiu o estabelecimento dos procedimentos de calibração com base em três métodos propostos por normas internacionais, mostrando serem apropriadas às dimensões da sala de irradiação projetada para essa finalidade. A decoração do espectro de nêutrons, a partir da determinação dos parâmetros de calibração para o detector de esferas de Bonner, permitiu determinar o espectro da fonte de ANTPOT.241 AmBe calibrada, com valores de taxa de fluência, taxa de dose equivalente e energia media, que corresponderam satisfatoriamente aos valores calculados esperados, possibilitando o uso de tal detector na dosimetria de área. Para a dosimetria pessoal, foi elaborado um sistema dosimétrico baseado no uso do polímero CR-39 e no ataque eletroquímico do mesmo. Para isso, foram projetadas e construídas uma câmara para o processamento do detector e uma fonte de alta tensão e alta frequência que mostraram-se adequadas às finalidades propostas. O dosímetro pessoal elaborado utiliza também material conversor (n, alfa) e seu principio de detecção possibilitou determinar um fator de calibração relacionando a resposta do detector com a dose recebida para nêutrons térmicos, epitérmicos e rápidos. Os parâmetros utilizados para o ataque eletroquímico foram: solução de KOH 6N, temperatura de 59°C, campo elétrico alternado de 20 kv IND.ppcm POT.-1, frequência de 2,0 kHz; para a detecção de nêutrons térmicos e epitérmicos o tempo de revelação empregado foi de 3 horas e para nêutrons rápidos de 6 horas. O sistema dosimétrico desenvolvido apresentou sensibilidades a nêutrons térmicos, epitérmicos e rápidos dadas pelos valores (1,46 +/- 0,09) 10 POT.4 traços cm POT.-2 mSv POT.-1, (9 +/- 3) 10² traços cm POT.-2 mSv POT.-1 e (26 +/- 4) traços cm POT.-2 mSv POT.-1 respectivamente. As doses mínimas e máximas detectáveis foram respectivamente 0,002 mSv e 0,6 mSv para nêutrons térmicos, 0,04 mSv e 8 mSv para nêutrons epitérmicos e 1 mSv e 12 mSv para nêutrons rápidos. Tendo em vista as implicações das recomendações do ICRP-60, pode-se concluir que o dosímetro pessoal elaborado neste trabalho apresenta a sensibilidade necessária no caso da monitoração de nêutrons térmicos e epitérmicos, mas que exigiria tempos de integração de doses superiores à mensal no caso da monitoração de nêutrons rápidos.O procedimento proposto para ser realizar a dosimetria de nêutrons é baseado no uso conjugado do dosímetro pessoal elaborado e do espectrômetro de esferas de Bonner enquanto dosímetro de área. / A neutron irradiation facility was designed and built in order to establish a procedure for calibrating neutron monitors and dosimeters. A 185 GBq ANTPOT.241 AmBe source in the air provides neutron doses rates between 9 nSv s POT.-1 and 0,5 muuSv s POT.-1. A calibrated 50 nSv s POT.-1 thermal neutron field is obtained by using a specially designed paraffin block in conjunction with the ANTPOT.241 AmBe source. A Bonner multisphere spectrometer was calibrated, using a procedure based on three methods proposed by international standards. The unfolded ANTPOT.241 AmBe neutron spectrum was determined from Bonner spheres data and resulted in a good agreement with expected values for fluence rate, dose rate and mean energy. A dosimetric system based on the electrochemical etching of CR-39 was developed for personal dosimetry. The dosimeter badge using a (n, alfa) converter, the etching chamber and high frequency power supply were designed and built specially for this project. The electrochemical etching (ECE) parameters used were: a 6N KOH solution, 59°C, 20 kV IND.ppcm POT.-1, 2,0 kHz, 3 hours of ECE for thermal and intermediate neutrons and 6 hours for fast neutrons. The calibration factors for thermal, intermediate and fast neutrons were determined for this personal dosimeter. The sensitivies determined for the developed dosimetric system were (1,46 +/- 0,09)10 POT.4 tracks cm POT.-2 mSv POT.-1 for thermal neutrons, (9 +/- 3)10² tracks cm POT.-2 mSv POT.-1 for intermediate neutrons and (26 +/- 4) tracks cm POT.-2 mSv POT.-1 for fast neutrons. The lower and upper limits of detection were respectively 0,002 mSv and 0,6 mSv for thermal neutrons, 0,04 mSv and 8 mSv for intermediate neutrons and 1 mSv and 12 mSv for fast neutrons. In view of the 1990s ICRP recommendations, it is possible to conclude that the personal dosimeter described in this work is sufficiently sensitive to thermal and intermediate neutrons but fast neutron monitoring at radiological protection level would require an integration period of over a month. The proposed dosimetric procedure is based on the conjugated use of the developed personal dosimeter and the Bonner multisphere spectrometer.

Page generated in 0.0388 seconds