• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 68
  • Tagged with
  • 68
  • 68
  • 39
  • 38
  • 21
  • 19
  • 9
  • 9
  • 8
  • 8
  • 7
  • 7
  • 7
  • 7
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Estudo estrutural da gliadina

Ribeiro, Andresa da Costa January 2012 (has links)
O objetivo deste trabalho visou realizar o estudo físico-químico da gliadina em solução, em diferentes solventes e sob variação de pH. Os solventes usados foram H2O deionizada, H2O/EtOH 40/60% v/v e dimetilsulfóxido (DMSO). As técnicas utilizadas foram Espalhamento de Luz (LS), Potencial Zeta (PZ) e Espectroscopia no Infravermelho por Transformada de Fourier (FTIR). LS revelou a presença de um sistema polidisperso para todas as amostras, com a presença de moléculas pequenas coexistindo com moléculas maiores. O coeficiente de difusão sofreu mudanças com a variação de pH, o que corroborou com os resultados de diâmetro observados. A gliadina em H2O deionizada e DMSO (pH 9,8) apresentaram uma menor distribuição de tamanho. Para as amostras em H2O/EtOH 40/60% v/v este fato foi observado apenas em pH 1,2. A análise de PZ forneceu informações sobre a estabilidade do sistema. Para a amostra em H2O deionizada, a estabilidade foi observada em pH 9,8. Em DMSO verificou-se uma instabilidade, com a presença de várias conformações coexistindo no sistema. A análise de FTIR-ATR mostrou-se adequado para o estudo da estrutura secundária. Em H2O deionizada, a conformação predominante é folhas-β. Em DMSO evidenciou-se uma banda em 1660 cm-1 (relacionado ao desenovelamento da proteína). Já em H2O/EtOH 40/60% v/v a conformação é instável. Em pH 1,2 foi observado um aumento na estrutura helicoidal. As diferentes conformações encontradas para a proteína e sua estabilidade em diferentes solventes e pHs fornecem uma idéia do potencial de aplicação desta proteína como biomaterial, em especial como bioadesivo. / This work presents the physical-chemical study of the gliadin in different solvents and pH, using Light Scattering (LS), Zeta Potential (ZP) and Fourier Transform Infrared Spectroscopy (FTIR) techniques. The solvents used were H2O, H2O/EtOH 40/60% v/v and dimethylsulfoxide (DMSO). Dynamic Light Scattering (DLS) indicated the presence of a polydispersity system for all samples (small and larger molecules coexisting). Samples in DMSO and H2O showed a lower size distribution at pH 9.8, while samples in H2O/EtOH 40/60% v/v only at pH 1.2. The ZP analysis were used to study the system stability, showing that the gliadin in water at pH 9.8 was the most stable system. In addition, the ZP results suggest that the gliadin in DMSO is unstable due to presence of several conformations of protein at all pH. The ATR-FTIR analysis showed to be appropriate for the secondary structure study, showing that the samples in H2O were predominantly β-sheets. In DMSO an absorption band was observed at 1660 cm-1 (this band indicate the unfolding of the protein). The conformations of samples in H2O/EtOH 40/60% v/v are unstable, besides at pH 1.2 it was observed that the helical structure increased. The several conformations and stabilities for the gliadin at different solvents and pH provide an idea of the application potential of this protein as a biomaterial, with a bioadesive.
32

Atividade antifúngica in vitro de própolis em fonsecaea pedrosoi utilizando ferramentas quimiométricas associadas à espectroscopia no infravermelho

Santos, Claisson Jodel dos January 2009 (has links)
Neste estudo, foi avaliada a atividade antifúngica in vitro de oito amostras de extratos etanólicos de própolis (EEP), provenientes da região central do estado do Rio Grande do Sul, Brasil, diante de doze amostras de Fonsecaea pedrosoi, através da técnica de microdiluição em caldo, preconizada pelo documento M28-A do Clinical and Laboratory Standards Institute (CLSI) e diluição em ágar. Através de cromatografia em camada delgada (CCD) foi realizada a caracterização fitoquímica e quantificação de compostos fenólicos totais. Os EEP com melhor atividade antifúngica foram das localidades de Santo Antônio da Patrulha e Candelária. Nas amostras, em geral, foi verificada a presença de produtos com perfil cromatográfico de terpenóides e flavonóides. A quantificação dos compostos fenólicos demonstrou que não há correlação entre a concentração e a atividade antifúngica. Através da utilização da espectroscopia de reflectância difusa no infravermelho com transformada de Fourier (DRIFTS) analisou-se o conjunto espectral dos EEP e das amostras de F. pedrosoi. Com o auxílio de ferramentas quimiométricas foi possível construir modelos com fatores mais relevantes e um menor número de variáveis, realizado pela análise por componentes principais (PCA) e após, agrupá-las de acordo com sua similaridade, através da análise por agrupamento hierárquico (HCA). Após, foi aplicado o algoritmo de regressão por mínimos quadrados parciais (PLS) que proporcionou a criação de modelos otimizados para previsão da atividade antifúngica.
33

Estudo de interações eletrônicas em algumas ciclanonas substituídas, por espectroscopia no infravermelho / Study of electronic interactions in some ciclanonas replaced by infrared spectroscopy

Bernadette Tostões Buzzi 19 October 1976 (has links)
Este trabalho investiga as interações entre o grupo carbonílico e enxofre, oxigênio ou dupla olefínica, através do estudo dos seguintes compostos: ciclopentanona (I), 3-tiaciclopentanona (II), 3-oxaciclopentanona (III), ciclohexanona (IV), 3-tiaciclohexanona (V), 3-oxaciclohexanona (VI), cicloheptanona (VII), 3-tiacicloheptanona (VIII), 4-tiaciclohexanona (IX), 4-tiacicloheptanona (X), ciclooctanona (XI), 5-tiaciclooctanona (XII) e 3-ciclohexenona (XIII). É fornecida uma revisão bibliográfica, na qual são apresentados os trabalhos sobre frequência de estiramento e basicidade relativa do grupo carbonílico de cetonas por espectroscopia no infravermelho, sendo destacados alguns aspectos mais intimamente ligados a este trabalho. Entre estes aspectos, podem ser enumerados: ressonância de Fermi na ciclopentanona, efeito de campo, efeito do tamanho do anel sobre a frequência e basicidade da carbonila, e impedimento estérico nas ciclanonas. São descritas as sínteses de algumas das cetonas da série estudada, a saber: 3-tiaciclopentanona (II), 3-tiaciclohexanona (V), 3-oxaciclohexanona (VI), 4-tiaciclohexanona (IX) e 4-tiacicloheptanona (X). São fornecidos os dados das medidas de deslocamentos das frequências de estiramento das hidroxilas de fenol e de p-clorofenol, em associação (1:1) com as treze cetonas cíclicas estudadas, à diluição infinita do doador em tetracloreto de carbono (ΔvoOH). São determinadas as constantes de associação (Kass) dos complexos formados entre p-clorofenol e cetonas (1:T), em tetracloreto de carbono, no infravermelho próximo, para as 3- e 4-tiaciclanonas (II), (V), (VIII), (IX) e (X), 3-oxaciclanonas (III) e (VI) e cetonas não substituidas correspondentes (I), (IV) e (VII). São apresentadas as frequências de estiramento do grupo carbonilico (vCO) das treze cetonas cíclicas estudadas, em tetracloreto de carbono. Os resultados de ΔvoOH e Kass para as ciclanonas substituídas em posições 3 e 4 por enxofre ou oxigênio, em comparação com as ciclanonas não substituídas correspondentes, indicam que: 1) 3-tiaciclanonas (II) , (V) e (VIII) apresentam uma diminuição de basicidade; 2) a ordem de diminuição de basicidade em 3-tiaciclanonas é: 3-tiaciclopentanona (II) > 3-tiaciclohexanona (V) = 3-tiacicloheptanona (VIII); 3) 4-tiaciclohexanona (IX) e 4-tiacicloheptanona (X) mostram uma diminuição de basicidade comparável à das 3-tiaciclanonas correspondentes; 4) 3-oxaciclopentanona (III) e 3-oxaciclohexanona (VI) apresentam uma diminuição de basicidade, que é da mesma ordem de grandeza em ambos os compostos; 5) a diminuição de basicidade em 3-oxaciclopentanona (III) é menor e em 3-oxaciclohexanona (VI) é maior do que nas tiaciclanonas correspondentes. As medidas de frequência de estiramento da carbonila (vCO) para as mesmas ciclanonas demonstram que: 1) não há diferenças significativas entre as frequências da carbonila de tiaciclanonas e ciclanonas não substituidas correspondentes; 2) há um aumento na frequência da carbonila, passando-se das ciclanonas não substituidas (I) e (IV) para as 3-oxaciclanonas correspondentes (III) e (VI). É apresentada uma discussão, em que a existência de possíveis interações é examinada pela interpretação dos dados experimentais, à luz dos efeitos indutivos e de campo, alterações no anel provenientes da introdução de um heteroátomo, e níveis de energia, proximidade e posição geométrica dos orbitais interagentes. É sugerida a ocorrência de uma interação no espaço significativa entre o heteroátomo e o grupo carbonílico em 3-tiaciclopentanona (II), 3-oxaciclopentanona (III) e 3-oxaciclohexanona (VI), e a ausência de uma tal interação Significativa em 3-tiaciclohexanona (V) e 3-tiacicloheptanona (VIII). Não se elimina, porém, a possibilidade da existência de uma fraca interação no espaço nos dois útimos compostos. O estudo de basicidade de 5-tiaciclooctanona (XII) e 3-ciclohexenona (XIII) indica: 1) um aumento na basicidade em relação às cetonas nao substituídas correspondentes; 2) um aumento de basicidade anormal com o aumento de concentração das cetonas em tetracloreto de carbono. Os dados de basicidade, em conjunto com os estudos efetuados paralelamente por Wladislaw e col. e com os resultados de outras medidas da literatura, permitem sugerir para a 5-tiaciclooctanona (XII) e 3-ciclohexenona (XIII): 1) a ocorrência de transferência de carga no estado fundamental; 2) a existência, em solução, de um equilíbrio entre duas conformações, uma em que há transferência de carga de enxofre ou dupla olefínica para a carbonila, e outra em que esta transferência é ausente. / This thesis investigates the interactions between the carbonyl group and sulphur, oxygen or ethylene double bond, in the following compounds: 3-thiacyclopentanone (I), 3-oxacyclopentanone (II), 3-thiacyclohexanone (III), 3-oxacyclohexanone (IV), 3-thiacycloheptanone (V), 4-thiacyclohexanone (VI), 4-thiacycloheptanone (VII), 5-thiacyclooctanone (VIII) and 3-cyclohexenone (IX), by comparison with the corresponding unsubstituted compounds. The thesis contains: A literature review on the stretching frequencies and relative basicities of the carbonyl group in ketones, in which some aspects connected with the present work, such as cyclopentanone Fermi ressonance, field effect, ring size influence and steric hindrance are emphasized. The syntheses of 3-thiacyclopentanone (I), 3-thiacyclohexanone (III), 3-oxacyclohexanone (IV), 4-thiacyclohexanone (VI) and 4-thiacycloheptanone (VII). The ΔvoOH data, as measured by i.r. shifts of OH stretching vibration of phenol and p-chlorophenol associated to the ketones studied (1:1), in carbon tetrachloride. The equilibrium constants (Kas.) for the association complexes (1:1) between p-chlorophenol and 3-and 4-thiacyclanones (I), (III), (V), (VI) and (VII) and 3-oxacyclanones (II) and (IV) and the corresponding unsubstituted ketones, in carbon tetrachloride, obtained from near infra-red measurements. The carbonyl stretching frequencies (vCO) for the ketones studied, in carbon tetrachloride. The basicities measurements data indicate that: 3-Thiacyclanones (I), (lII) and (V) are less basic than the corresponding unsubstituted ketones. The basicities decrease order in 3-thiacyclanones is: 3-thiacyclopentanone (I) > 3-thiacyclohexanone (III) = 3-thiacycloheptanone (V). The basicity decrease in the 4-thiacyclohexanone (VI) and 4-thiacycloheptanone (VII) is similar to that obtained for the corresponding 3-thiacyclanones. 3-Oxacyclopentanone (II) and 3-oxacyclohexanone (IV) show similar basicity decrease. The basicities of 3-oxacyclopentanone (II) and 3-oxacyclohexanone (IV) are, respectively lower and higher than those of the corresponding thia analogues. 5-Thiacyclooctanone (VIII) and 3-cyclohexenone (IX) are more basic than the corresponding unsubstituted ketones. An abnorml raise of basicity occurs in 5-thiacyclooctanone (VIII) and 3-cyclohexenone (IX) with the increase of concentration in carbon tetrachloride. The carbonyl stretching frequency measurements (vCO) show that: The vCO values for thiacyclanones do not differ significantly from those for the corresponding unsubstituted ketones. 3-Oxacyclanones exhibit higher vCO values than the corresponding unsubstituted ketones. A discussion is presented, in which: The possibility of through-space and through-bond interactions in the 3- and 4-substituted cyclanones is considered by examination of experimental data in the light of the possible effects described in the literature review, energy levels, proximity and geometry of the interacting orbitals. The possibility of a charge transfer from the sulphur atom or ethylene double bond to the carbonyl group in 5-thiacyclooctanone (VIII) and 3-cyclohexenone (IX) is examined by comparison of the experimental data of the present thesis with those reported in the 1iterature and those obtained by B.Wladislaw et al. The following conclusions are presented: A significant through-space interaction between sulphur or oxygen atoms and carbonyl group takes place in the 3-thiacyclopentanone (I), 3-oxacyclopentanone (II) and 3-oxacyclohexanone (IV). There is no evidence for a sicnificant through-space interaction between sulphur atom and carbonyl group in 3-thiacyclohexanone (III) and 3-thiacycloheptanone (V), though a weak interaction may be present. 5-Thiacyclooctanone (VIII) and 3-cyclohexenone (IX) exist in solution, as an equilibrium mixture of two conformations, one in which charge transfer occurs and another in which it is absent.
34

Monitoramento em linha e em tempo real do diâmetro médio das partículas e dos teores de não voláteis e monômero durante a polimerização em emulsão usando espectroscopia NIR. / In-line real-time monitoring of average particle size and solids monomer contents during emulsion polymerization using NIR spectroscopy.

Silva, Wandeklébio Kennedy da 02 April 2009 (has links)
A técnica de polimerização em emulsão tem sido usada cada vez mais na indústria de tintas, resinas, plásticos, entre outros. Esse crescimento se deve as razões ambientais (uma vez que se utiliza água como fase contínua desta reação), também a versatilidade e a capacidade de produzir látex com diferentes propriedades para diferentes aplicações. Polímeros em emulsão são produtos por processo, isto é, suas propriedades são definidas durante a polimerização. Por isso, é importante o adequado monitoramento da reação de modo a permitir o controle das propriedades desejadas. A técnica de espectroscopia na região do infravermelho próximo (NIR), combinada com o uso de fibras óticas, é muito promissora para o monitoramento multivariável, em linha e em tempo real do processo de polimerização. O objetivo deste trabalho foi o de estudar o uso de espectroscopia NIR para o monitoramento em linha e em tempo real das concentrações de monômero e de não- voláteis (conhecido também como teor de sólidos) e da evolução do tamanho médio das partículas de látex (Dp) durante a reação de polimerização em emulsão de metacrilato de metila (MMA), em escala de laboratório e processo semi-batelada. Os modelos de calibração para estas variáveis foram obtidos experimentalmente empregando o método de regressão por mínimos quadrados parciais, PLS. Os resultados obtidos confirmaram algumas regiões espectrais do NIR indicadas em literatura como sendo adequadas na predição de monômero e Dp e revelaram -1 comportamentos espectrais ainda não explicados na região entre 10.475 e 13.000 cm , relacionados às variações no tamanho das partículas. Os resultados mostram também que é possível monitorar em linha e em tempo real a evolução do Dp e dos teores de monômero (MMA) e de não voláteis, simultaneamente em um único instrumento, utilizando modelos de calibração com bandas espectrais e pré-tratamentos distintos. / Emulsion polymerization is a largely and increasingly used technique in industrial production of paints, resins, plastics among others. This increase is due to environmental reasons (since water, rather than organic solvents is used as dispersing medium), as well as to the versatility and capacity of producing products with different properties for different applications. Emulsion polymers are products by process, i.e., the properties are mainly defined during the polymerization process. Thus, the adequate process monitoring is important for achieving the target properties. The NIR spectroscopy combined with optical fibers is a promising technique for the task of multivariable, real-time, in-line monitoring of polymerization processes. The aim of this work is the study of use of NIR spectroscopy for in-line, real time monitoring of the monomer and solids content, as well as the evolution of average size of the polymer particles (Dp), during semi-batch emulsion polymerization of methyl methacrylate in laboratory reactor. The calibration models for each of the monitored variables were obtained by applying the partial least squares regression method (PLS). The results confirmed that some NIR spectral ranges recommended in the literature are appropriate for the prediction of monomer content and Dp, and that there are spectral -1 . The results behaviors not yet explained in the region between 10475 and 13000cm also show that the in-line, the changes in Dp, monomer and polymer content can be simultaneously monitored in-line and in real time by NIR spectroscopy by using calibration models based on adequate spectral regions and distinct data pretreatments.
35

Avaliação do grau de sorção, solubilidade e taxa de conversão de sistemas adesivos irradiados com laser de diodo / Evaluation of water sorption/solubility and conversion degree of the adhesive systems irradiated with diode laser

Brianezzi, Leticia Ferreira de Freitas 03 March 2015 (has links)
O LASER tem sido utilizado previamente a polimerização de sistemas adesivos em dentina como uma estratégia para melhorar as suas propriedades. O objetivo deste estudo foi investigar o efeito do LASER de diodo na sorção (SB), solubilidade e grau de conversão das principais categorias de sistemas adesivos. Quatro sistemas adesivos foram testados: convencional de 3 passos (Adper&#x2122; Scotchbond&#x2122; Multi-Purpose-MP), convencional de 2 passos (Adper&#x2122; Single Bond 2-SB), autocondicionante de 2 passos (Clearfil&#x2122; SE Bond-SE) e o sistema universal (Adper&#x2122; Single Bond Universal-SU). O adesivo fluido foi dispensado numa matriz de teflon (6.0 x 6.0 x 1 m),irradiado com laser de diodo com 970 nm e polimerizado com luz LED. Para o teste de sorção e solubilidade foram preparados espécimes em uma matriz de teflon quadrada (n=10): MP, SB, SE e SU (sem irradiação) e MP-L, SB-L, SE-L e SU-L (grupos com irradiação). Essa mensuração foi monitorando a mudança de massa depois dos ciclos de armazenamento de desidratação/ água. Para o grau de conversão, espécimes similares eram preparados e divididos 8 grupos iguais (n=5), utilizando a espectroscopia infravermelho transformada de Fourrrier (FTIR) com reflectância total atenuada (ATR). Cada espécime era comprimido contra o cristal do ATR (diamante/ZnSe) com um pressão micrométrica. As amostras não polimerizadas (&#x2248;3.0&#x3BC;L, n=5) de cada adesivo era escaneada para calcular o grau de conversão. Para sorção (&#x3BC;g/mm3) houve diferença estatisticamente significante para ambos os fatores (p<0.05) sem interação entre eles SB> SU> MP> SE. Para a solubilidade (&#x3BC;g/mm3), somente o fator adesivo foi significante (p<0.05): SB>SU>MP=SE. A irradiação do LASER antes da polimerização aumentou o grau de conversão dos sistemas adesivos SBL> MP-L> SE-L> MP> SB> SE> SU-L> SU. A irradiação aumentou a sorção, mas não afetou a solubilidade dos sistemas adesivos. Além disso, a irradiação com LASER de diodo melhorou o grau de conversão de três sistemas adesivos testados. / Laser irradiation has been used over the dentin bonding systems (DBS) prior to polymerization as a strategy to improve their properties. The aim of this study was to investigate the effect of diode laser on water sorption (WS), solubility (WSB) and conversion degree (DC) of main categories of DBS. Four bonding agents were tested: 3-step total-etch (Adper&#x2122; Scotchbond&#x2122; Multi-Purpose-MP), 2-step total-etch (Adper&#x2122; Single Bond 2-SB), 2-step self-etch Clearfil&#x2122; SE Bond-SE) and universal system (Adper&#x2122; Single Bond Universal-SU). The fluid DBSs were dispensed into Teflon molds (6.0 x 6.0 x 1mm), irradiated with a 970 nm diode laser and then polymerized with a LED curing unit. For WS/WSB tests, square-shaped DBS were prepared (n=10): MP, SB, SE and SU (control groups/ no laser irradiation) and MP-L, SB-L, SE-L and SU-L (laser irradiated groups). WS/WSB were measured by monitoring the mass changes after dehydration/water storage cycles. For DC tests, similar square-shaped specimens were prepared and assigned into eight similar groups (n=5), using Fourier transform infrared spectroscopy (FT-IR) with attenuated total reflectance (ATR). Each cured specimen was compressed against the ATR crystal (diamond/ZnSe) with a micrometric, low-pressure clamp. Uncured resin samples (&#x2248;3.0&#x3BC;L, n=5) of each adhesive were also scanned for DC calculation. For WS (&#x3BC;g/mm3), both factors were statistically significant (p<0.05), without interaction between them SB>SU>MP>SE. For WSB (&#x3BC;g/mm3), only DBS was a significant factor (p<0.05): SB>SU>MP=SE. Laser irradiation immediately before photopolymerization has increased the DC (%) of the tested adhesives: SB-L> MPL> SE-L> MP> SB> SE> SU-L> SU. Irradiation with diode laser improved the conversion degree of all tested dentin bonding systems. Furthermore the diode laser increased the sorption, but did not affect their water solubility.
36

Formulações sólidas de lactase: estudos de estabilidade acelerada, liberação e sua quantificação por espectroscopia no infravermelho

PERISSINATO, Aline Gravinez 21 January 2016 (has links)
A intolerância à lactose é caracterizada pela falta da enzima lactase (β-galactosidase) e atinge quase 50% da população. O tratamento se baseia em uma dieta restritiva de produtos lácteos o que pode acarretar em prejuízo nutricional e estar associada com a diminuição da densidade mineral óssea e fraturas. Nosso objetivo foi avaliar uma formulação de lactase gastro-resistente para garantir uma maior atividade no local de ação da enzima (lúmen do intestino delgado). Concomitantemente, também avaliamos a estabilidade e a atividade enzimática do produto comercial americano (comprimidos de Lactaid® 9000 U). E por fim, desenvolvemos um método analítico para quantificar o teor de lactase em formulações sólidas através da espectroscopia na região do infravermelho. Ao realizar o teste de estabilidade nota-se que a embalagem primária é fundamental na manutenção da atividade enzimática da lactase. Ao término do estudo de estabilidade, os comprimidos que estavam dentro da sua embalagem primária tiveram uma diminuição da sua atividade de aproximadamente 7,5%, enquanto os comprimidos que foram armazenados fora da sua embalagem original tiveram uma perda de aproximadamente 35%. Ao realizar o teste de dissolução também do produto comercial americano nota-se que a formulação existente não é capaz de proteger a enzima da ação degradante do ambiente gástrico do estômago, apresentando ao final do teste uma perda de 65% de atividade enzimática. Em comparação com a forma farmacêutica gastro-resistente, não houve perda de atividade durante a etapa ácida e ao final do ensaio de dissolução a atividade encontrada foi de 93%. Quanto ao método de quantificação por infravermelho, constatou-se que a o melhor modelo de calibração multivariada (PLS) apresenta 7 VL, RMSECV de 4,3 %, RMSEP de 1,2% e os dados obtidos com o MIR é muito similar com os dados obtidos pelo método USP de referência. / Lactose intolerance is characterized by the absence of the enzyme lactase (β-galactosidase) and affects almost 50% of the population. The treatment is based on a restrictive diet of dairy products which can result in nutritional loss and is associated with decreased bone mineral density and fractures. Our aim was to evaluate a lactase gastro formulation to ensure increased activity in the action site of the enzyme (lumen of the small intestine). Simultaneously, we also evaluated the stability and enzyme activity of the american commercial product (tablets of Lactaid® 9000 U). And lastly, we developed an analytical method for measuring the lactase content in solid formulations by spectroscopy in the infrared region. In carrying out the stability test to note that the primary packaging is critical in maintaining the enzymatic activity of lactase. At the end of the stability study, the tablets that were in the primary package had a decrease in their activity by approximately 7.5%, while the tablets were stored outside of its original container had a loss of approximately 35%. When carrying out dissolution test also the american commercial product it is noted that the existing formulation is not able to protect the enzyme from the degrading action of gastric environment of the stomach, with the end of the test a loss of 65% of enzyme activity. Compared with the gastroresistant pharmaceutical form there was no loss of activity during the acid step and the end of the dissolution test the activity was found 93%. As regards the measurement method by IR, it was found that the best multivariate calibration model (PLS) features 7 LV, RMSECV 4.3%, RMSEP of 1.2% and the data obtained with MIR is very similar to the data obtained by the USP reference method. / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES
37

Identificação da procedência geográfica da erva mate (llex paraguariensis) mediante análise elementar, reflexão no infravermelho próximo e quimiometria

Marcelo, Marcelo Caetano Alexandre January 2013 (has links)
Neste trabalho foi desenvolvido um método de análise de erva mate mediante as técnicas de espectroscopia no infravermelho próximo (NIR), espectrometria de emissão óptica com plasma indutivamente acoplado (ICP OES) e espectrometria de massa com plasma indutivamente acoplado (ICP-MS), com o intuito de classificar a erva mate por país de origem da América do Sul. Para isto, foram utilizados métodos de análise multivariada supervisionada e não supervisionada, como a análise hierárquica por agrupamentos (HCA), a análise por componentes principais (PCA), o método do k-ésimo vizinho mais próximo (kNN), soft independent modeling class analogy (SIMCA), análise discriminante por mínimos quadrados parciais (PLS-DA) e análise discriminante por máquinas de vetor de suporte (SVM-DA). Foram analisadas 54 amostras de erva mate provenientes da América do Sul (Argentina, Brasil, Paraguai e Uruguai). As amostras foram cominuídas em moinho criogênico e diretamente analisadas para a obtenção dos espectros de reflexão no NIR. Para a determinação dos elementos Ca, K, Mg, Al, Fe, Mn, Ba, Cu, P, Sr e Zn por ICP OES e Li, Be, Ti, V, Cr, Ni, Co, As, Se, Rb, Mo, Ag, Cd, Sb, La, Ce, Pb, Bi e U por ICP-MS, foi realizada a decomposição das amostras por via úmida em bloco digestor em sistema fechado. A classificação da erva mate por país de origem foi possível, sendo que a melhor classificação para todos os métodos de análise multivariada foi obtida por NIR e para as concentrações dos elementos avaliados, a SVM-DA foi o melhor. Conclui-se que a erva mate pode ser avaliada por país de origem mediante a técnicas de ICP OES, ICP-MS e NIR. / A method of yerba mate analyzis using near infrared spectroscopy (NIR), inductively coupled plasma optical emission spectrometry ( ICP OES ) and inductively coupled plasma mass spectrometry (ICP-MS) was developed in order to classify yerba mate by country of origin in South America. To this end, principal components analysis (PCA), k-nearest neighbor (KNN), soft independent modeling class analogy (SIMCA), partial least square discriminant analysis (PLSDA), discriminant analysis by vector machine (SVM-DA) were used for multivariate analysis of the NIR spectra and element concentrations found in 54 samples of yerba mate from South America (Argentina, Brazil, Paraguay and Uruguay ). The samples were ground in cryogenic mill and directly analyzed in order to obtain the reflectance spectra in the NIR region. For elements determination (Ca, K, Mg, Al, Fe, Mn, Ba, Cu, P, Sr and Zn by ICP OES and Li, Be, Ti, V, Cr, Ni, Co, As, Se, Rb, Mo, Ag, Cd, Sb, La, Ce, Pb, Bi and U by ICP-MS), the samples were acid digested in closed vessel in digestion block. The classification of the yerba mate by country of origin was possible, whereas the best classification using all multivariate analysis methods was obtained for NIR. For the element concentrations, the best classification was obtained by SVM-DA. It was concluded that yerba mate classification by country of origin can be assessed through ICP OES, ICP-MS and NIR.
38

Influência da composição de resinas compostas no grau de conversão e degradação hidrolítica

Jassé, Fernanda Ferreira [UNESP] 03 August 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:35Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-08-03Bitstream added on 2014-06-13T19:09:28Z : No. of bitstreams: 1 jasse_ff_me_arafo.pdf: 3143943 bytes, checksum: db74ccbc66112c4a240ca5402754512c (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Numerosos tipos e marcas comerciais de resinas compostas são constantemente introduzidos no mercado odontológico, em função de modificações na composição, tipo, formato e quantidade das partículas inorgânicas, assim como na porção orgânica. Sempre, com a finalidade de proporcionar propriedades mecânicas e estéticas superiores aos materiais, aumentando dessa forma sua longevidade. Assim, o propósito neste estudo foi avaliar o grau de conversão (GC) pelo método FT-IR e a degradação hidrolítica por meio do teste de dureza Vickers (dV), de duas resinas compostas (uma nanoparticulada e uma micro-híbrida). Para isso, oito espécimes (4 mm de diâmetro x 2 mm de espessura, ISO 4049) de cada material foram confeccionados para cada teste. As resinas compostas foram inseridas em única porção na matriz metálica e fotoativadas com aparelho LED (Celalux, Voco®, 776 mW/cm²), por 40 segundos. Dezesseis leituras de dV (8 no topo e 8 na base) foram realizadas para cada espécime em durômetro digital MMT-3 (Buehler Lake Bluff, Illinois USA), utilizando carga de 50 gf aplicada durante 30 segundos, em intervalos de tempo prédeterminados: imediatamente após fotoativação (controle), 24, 48, 72 horas, 7, 14, 21, 30 dias e 6 meses. Logo após a fotoativação foi feita a medida da dureza inicial e os espécimes foram então imersos em saliva artificial a 37°C. Para o GC (%), os espécimes foram triturados, prensados com KBr e analisados em espectrofotômetro FT-IR (Nexus-470). Os resultados foram submetidos à análise estatística e permitiram concluir que: não foi observada diferença entre as resinas quanto ao grau de conversão; a proporção entre as medidas de dureza de topo e base foi semelhante para os dois materiais, tendo sido mantida ao longo de todo o tempo experimental; a resina Z-250 apresentou os maiores valores de dureza tanto na superfície de topo quanto na de base... / Numerous types and brands of composite resins are constantly introduced into the dental market, due to changes in the composition, type, shape and quantity of inorganic particles as well as the organic portion. Always with the aim of providing superior mechanical and aesthetic properties to materials, thereby increasing their longevity. Thus, the purpose of this study was to evaluate the degree of conversion (DC) and hydrolytic degradation through the Vickers hardness test (hV) of two composites (a nanofilled and a microhybrid). For this, eight specimens (4 mm diameter x 2 mm thick, ISO 4049) of each material were prepared for each test. The composites were inserted into single increment in the metallic matrix and photoactivated with a LED unit (Celalux, Voco ®, 776 mW / cm ²) for 40 seconds. Sixteen hV readings (8 on each top and bottom surfaces) were performed for each specimen in MMT-3 digital hardness tester (Buehler Lake Bluff, Illinois USA), using load of 50 gf applied for 30 seconds, at predetermined intervals: immediately after polymerization (control), 24, 48, 72 hours, 7, 14, 21, 30 days and 6 months. After curing, initial hardness measurements were performed and the specimens were immersed in artificial saliva at 37 °C. For the DC (%), the specimens were ground, pressed with KBr and analyzed by FT-IR spectrophotometer (Nexus-470). The results were subjected to statistical analysis and concluded that: there was no difference between the resins for degree of conversion; the ratio between top and bottom hardness values was similar for both materials and was maintained throughout the experimental period; the composite resin Z-250 showed the highest hardness values in both the top surface as the bottom throughout the evaluation period. The materials tested showed no evidence of hydrolytic degradation in a significant way, in a six-month storage-time in artificial saliva
39

Avaliação da conversão da resina composta polimerizada com luz halógena e LED com espectometria do infravermelho

Sarabia Quiroz, Ana María [UNESP] 04 March 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:08Z (GMT). No. of bitstreams: 0 Previous issue date: 2004-03-04Bitstream added on 2014-06-13T20:12:00Z : No. of bitstreams: 1 sarabiaquiroz_am_me_arafo.pdf: 3560698 bytes, checksum: f88f8b3c667a0f2fcd2dd88014f22ffb (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O presente estudo avaliou a conversão da polimerização de resinas compostas expostas à luz halógena e LED. Foram realizados corpos de prova e divididos em 64 grupos experimentais, onde variaram o tipo de luz (halógena e LED) utilizada, tempo de exposição à luz (20 e 40 segundos), profundidade do corpo de prova (1,2,3,e 4mm) e tempo de avaliação após a irradiação (0, 24,48 e 168 horas após a irradiação), cada grupo tinha cinco repetições. Os corpos de resina foram cortados e armazenados em ambiente seco e escuro. Foram confeccionadas pastilhas com 5mg de KBr e 50æg de pó de resina e os picos de absorbância foram registrados com o espectrômetro de infravermelho (FTIR). Os valores de conversão foram determinados na proporção das áreas obtidas com Microcal Origin 6.0 de C=O (pico em 1720) / C=C (pico em 1638). Os resultados da conversão foram analisados estatisticamente com os testes de ANOVA e Tukey. Obtendo-se, os seguintes resultados: A luz Halógena dá melhores resultados de polimerização que o LED, 40 segundos de exposição a luz dá melhores resultados de conversão, independente do tipo de luz, a menor profundidade o valor de conversão é melhor as 168 horas, que as observadas as 24 e 0 horas. Concluindo-se, que a conversão de polimerização das resinas compostas está influenciada pela fonte de luz, tempo de exposição à luz, profundidade do corpo de prova e tempo de avaliação. / The purpose of this study was to determine the polymerization conversion of the resin-composites exposed to halogen light and LED. Five specimens were made for each of the 64 groups, varying type of light (halogen and LED), time of exposure (40 and 20 seconds) deepness of the specimen (1, 2, 3 and 4mm) and time of the evaluation (0, 24, 48 and 168 hours after light irradiation) .The specimens were stored in a dry and dark area and were pulverized into a fine powder with a mortar and a pestle. Fifty æg of powder were mixed with approximately 5mg of potassium bromide, and the absorbance peaks were recorded by FTIR. The value of conversion was determined from the ratio of areas obtained with Microcal Origin 6.0 of C=O (peak at 1720) /C=C (peak at 1638). The results were statistically analyzed with ANOVA and Tukey tests. The results observed were the following: i) halogen light gives better polymerization results than LED light, ii) 40 seconds to light exposure give s better results of conversion, iii) as less deepness , more is the conversion (with both types of light) , iv) With 168 hours of observation, the polymerization is better than with 0 or 24 hours of observation. Conclusion: polymerization conversion of the resin composites is influenced by the type of light, time of exposure to light, deepness of the specimen and time of observation.
40

Impacto da adi??o do hidr?xido de c?lcio em adesivos autocondicionantes experimentais: influ?ncia no grau de convers?o e PH

Amorim, D?bora Michelle Gon?alves de 18 July 2017 (has links)
Submitted by Automa??o e Estat?stica (sst@bczm.ufrn.br) on 2017-10-05T00:11:27Z No. of bitstreams: 1 DeboraMichelleGoncalvesDeAmorim_DISSERT.pdf: 1045671 bytes, checksum: 9457f9af138fc5b16cd8f13019d85f5a (MD5) / Approved for entry into archive by Arlan Eloi Leite Silva (eloihistoriador@yahoo.com.br) on 2017-10-16T22:23:08Z (GMT) No. of bitstreams: 1 DeboraMichelleGoncalvesDeAmorim_DISSERT.pdf: 1045671 bytes, checksum: 9457f9af138fc5b16cd8f13019d85f5a (MD5) / Made available in DSpace on 2017-10-16T22:23:08Z (GMT). No. of bitstreams: 1 DeboraMichelleGoncalvesDeAmorim_DISSERT.pdf: 1045671 bytes, checksum: 9457f9af138fc5b16cd8f13019d85f5a (MD5) Previous issue date: 2017-07-18 / Objetivo: Avaliar o impacto da adi??o do hidr?xido de c?lcio ? Ca(OH)2 na neutraliza??o do pH e grau de convers?o de adesivos autocondicionantes experimentais. M?todos: Quatro adesivos foram formulados em dois frascos: Frasco A, contendo UDMA, HEMA, GDMA-P, TPO, DH e solvente; Frasco B: composto por UDMA, HEMA, TPO, DH, solventes. Os solventes utilizados foram etanol e ?gua (1:1). A vari?vel de formula??o testada foi a concentra??o de Ca(OH)2, adicionado ao frasco B, nas fra??es em massa de 0% (controle), 1%, 2% e 4%. Sendo assim, os adesivos foram divididos em quatro grupos (A+B0; A+B1; A+B2; A+B4). Volumes iguais dos frascos A e B de cada adesivo foram misturados e ~5ul dessa mistura foram inseridos em moldes de silicona para confec??o dos discos. Antes da polimeriza??o do adesivo, o pH dos mesmos foi aferido, atrav?s de um pHmetro. Ap?s a fotoativa??o, os discos (n=5) foram imersos em ?gua destilada, e leituras do pH do eluato foram realizadas por 72h. Para avalia??o do grau de convers?o, cinco amostras de cada adesivo foram submetidas ao FTIR, com dispositivo de reflect?ncia total atenuada (ATR), antes e ap?s a fotoativa??o das amostras. Para os procedimentos de fotoativa??o, foi utilizada uma fonte de luz LED de 3? gera??o - Bluephase G2. Os dados foram estatisticamente avaliados por meio dos testes ANOVA 1 fator (grau de convers?o e pH do adesivo) e 2 fatores (pH do eluato) e p?s teste de Tukey (p<0,05). Resultado: No teste de grau de convers?o n?o foi encontrado diferen?a estatisticamente significativa entre os adesivos experimentais testados. O pH dos adesivos experimentais testados foram todos estatisticamente diferentes entre si. O pH do eluato foi neutralizado nos gupos A+B2 e A+B4 ap?s o per?odo de imers?o. Conclus?o: o grau de convers?o n?o foi afetado pela incorpora??o do hidr?xido de c?lcio. O pH do adesivo e do eluato foi neutralizado com a adi??o do hidr?xido de c?lcio. / Purpose: To evaluate the impact of the addition of calcium hydroxide - Ca (OH) 2 on the neutralization of pH and degree of conversion of experimental self - etching adhesives. Methods: Four adhesives were formulated in two flasks: Bottle A, containing UDMA, HEMA, GDMA-P, TPO, DH and solvent; Bottle B: composed of UDMA, HEMA, TPO, DH. The solvents used were ethanol and water (1: 1). The concentration of Ca (OH) 2, added to flask B, in the mass fractions of 0% (control), 1%, 2% and 4% was evaluated, and the adhesives were divided into four groups (A + B0, A + B1, A + B2, A + B4). Equal volumes of bottles A and B of each adhesive were mixed and ~ 5 ? of this mixture was inserted into silicone molds to make the disks. Before polymerization of the adhesive the pH of the adhesive was measured through a pH meter. After the photoactivation, the disks (n = 5) were immersed in distilled water, and pH readings of the eluate were performed for 72h. To evaluate the degree of conversion, five samples of each adhesive were submitted to the FTIR, with attenuated total reflectance (ATR) device, before and after the photoactivation of the samples. For the photoactivation procedures, a 3rd generation LED light source - Bluephase G2 was used. The data were statistically evaluated by ANOVA 1 factor (degree of conversion and pH of the adhesive) and 2 factors (pH of the eluate) and Tukey's post-test (p <0.05). Results: No statistically significant difference was found between the experimental adhesives tested in the conversion test. The pH of the experimental adhesives tested were all statistically different from each other. The pH of the eluate was neutralized in the A + B2 and A + B4 groups after the immersion period. Conclusion: the degree of conversion was not affected by the incorporation of calcium hydroxide. The pH of the adhesive and the eluate was neutralized with the addition of calcium hydroxide. Keywords: Calcium Hydroxide, Spectroscopy, Fourier Transform Infrared, Dentin-Bonding Agents.

Page generated in 0.0998 seconds