Spelling suggestions: "subject:"estações"" "subject:"gestações""
21 |
Influência da recirculação de água de lavagem de filtros na qualidade da água tratada para consumo humano / Influence of recirculation of water to wash filters in treated water quality for human consumptionCampos, Marlon Caianelo Dias, 1986- 24 August 2018 (has links)
Orientador: Ricardo de Lima Isaac / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-24T14:00:51Z (GMT). No. of bitstreams: 1
Campos_MarlonCaianeloDias_M.pdf: 3410126 bytes, checksum: bb9db3577d3074777f6ae59b1de2ad29 (MD5)
Previous issue date: 2014 / Resumo: A recirculação de água de lavagem de filtro em estação de tratamento de água do tipo convencional (ETA) pode representar economia significativa tanto do recurso hídrico quanto de energia, aspecto fundamental do ponto de vista da sustentabilidade. Contudo, se praticada sem critério, tal prática operacional pode representar risco à saúde do consumidor. O objetivo geral desta pesquisa foi avaliar o impacto da recirculação da água de lavagem de filtros (ALAF) na qualidade da água tratada. O trabalho desenvolveu-se na ETA-3 de Campinas-SP que capta do manancial superficial (rio Atibaia), utiliza pré-cloração e policloreto de alumínio como coagulante no processo de tratamento. Investigou-se em escala de bancada (Jar-test) o impacto da aplicação de taxas de recirculação equivalentes a 2, 4, 6, 8 e 10 % em volume de ALAF em relação ao volume total de água tratada na formação de subprodutos de desinfecção (trihalomeanos e ácidos haloacéticos). Os parâmetros carbono orgânico total (COT), carbono orgânico dissolvido (COD), UV254, turbidez, cor (aparente e verdadeira) e metais (alumínio, bário, cádmio, chumbo, cobre, cromo, manganês, zinco e níquel) foram também avaliados. Em geral, as diferentes taxas de recirculação de ALAF não provocaram inadequações quanto ao padrão de potabilidade para os parâmetros: cor, turbidez, metais (bário, cádmio, chumbo, cobre, cromo, manganês, zinco e níquel) e trihalometanos. Quanto aos ácidos haloáceticos, porém, notou-se que não se atendeu ao valor limite estabelecido na legislação e que o aumento da taxa de recirculação provocou a elevação da concentração deste subproduto da desinfecção na água tratada / Abstract: Filter backwash water recycling at conventional water treatment plants (WTP) certainly contributes to water and energy resources rational use, essential for sustainability. However, if practiced without criteria, such operational practice may pose a risk to users¿ health. The overall objective of this research was to evaluate the impact of recirculating filter backwash water on filtered water quality. The work was carried out at Campinas WTP, Sao Paulo State, Brazil. The plant treats surface raw water from Rio Atibaia (pre-chlorination, polyaluminum chloride as main coagulant). It was investigated in lab scale (jar-test) the effect of applying recirculation flowrate corresponding to 2, 4, 6, 8 and 10 % volume of backwash water ratio to total volume of treated water on the formation of disinfection byproducts (trihalomethane, THM and haloacetic acids, HAA). Metals content (aluminum , barium, cadmium, lead, copper, chromium , manganese, zinc and nickel), total organic carbon (TOC), dissolved organic carbon (DOC) , UV254 , turbidity, apparent and true color were also evaluated . In general, tested recirculation rates did not cause filtered water quality mismatches to drinking water standards for the parameters: color, turbidity, metals (barium, cadmium, lead, copper, chromium, manganese, zinc and nickel) and THM. However, for HAA it was found that recycling led to concentration values upper than the maximum contaminant level in Brazilian drinking water standards. Increasing the rate, higher was the concentration of this disinfection by-product in treated water / Mestrado / Saneamento e Ambiente / Mestre em Engenharia Civil
|
22 |
Protótipo de biofiltro percolador com uso de meio suporte sintético / Prototype of biofilter percolator with synthetic supportBergamini, Natália Cedran, 1984- 26 August 2018 (has links)
Orientador: Carlos Gomes da Nave Mendes / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-26T02:02:33Z (GMT). No. of bitstreams: 1
Bergamini_NataliaCedran_M.pdf: 5745897 bytes, checksum: 69560c23a66d8d968b36f4b34e17bc8d (MD5)
Previous issue date: 2014 / Resumo: Este trabalho consistiu em inovação tecnológica antes nunca testada desde a concepção, projeto, construção e operação de um biofiltro percolador de tratamento de esgoto sanitário em escala piloto. O reator foi desenvolvido nas instalações do Laboratório de Protótipos da Faculdade de Engenharia Civil da UNICAMP, cidade de Campinas, estado de São Paulo, é constituído de pré-filtro fabricado com a manta acrílica resinada, 3 reatores biológicos percoladores dispostos em séries, revestidos de não tecido sintético e filtro secundário confeccionado do mesmo material do pré-filtro. A vazão real média de alimentação do sistema era de 12,8 L h-1, tendo sido operado em regime hidráulico com tempo de detenção hidráulico variável de 82 a 100 minutos. A inovação baseou-se no uso de não tecido sintético com tripla função: a) proporcionar o fluxo do substrato sob ação da gravidade; b) promover a troca gasosa entre o meio líquido e a atmosfera; e c) constituir-se como meio suporte da biomassa, além de verificar as condições operacionais e tipos de mantas para viabilizar o tratamento de esgoto na remoção de matéria carbonácea sem a necessidade de aeração artificial. Neste estudo, foi analisada a remoção de sólidos suspensos (SS), turbidez, oxigênio dissolvido, DQO e DBO5. Os resultados médios de remoção de DQO e de DBO nas diferentes fases operacionais variaram de 75 a 86% e de 80 a 86%, respectivamente. As concentrações médias de DQO no efluente final variaram de 81 a 179 mg/L, enquanto as concentrações médias de DBO estiveram entre 47 a 97 mg/L. As médias globais de SST no efluente final foram mantidas em 49 mg/L. Com remoção de turbidez de 92,8%. O sistema PF/FBP (Pré-filtro/Filtro Biológico Percolador) pode se tornar uma alternativa muito promissora para o tratamento de esgoto sanitário de pequenas instalações do Brasil, uma vez que o sistema manifestou baixos tempo de detenção hidráulica e eficiência na remoção de DQO, DBO5 e sólidos suspensos, resultando em uma instalação compacta e de baixos custos. Além disso, o consumo de energia e os custos operacionais são mínimos / Abstract: This work consisted in technological innovation never before tested from conception, design, construction and operation of a trickling biofilter wastewater treatment in pilot scale. The reactor was developed on the premises of the Laboratory Prototypes of the Faculty of Civil Engineering, UNICAMP, Campinas, São Paulo, is constituted of prefilter manufactured with resin-coated acrylic blanket, three biological trickling reactors arranged in series, coated and synthetic nonwoven secondary filter made of the same material pre-filter. The average real power flow of the system was 12,8 L h-1, having been operated hydraulic system with variable hydraulic detention time of 82-100 minutes. The innovation is based on the use of non-synthetic fabric with three functions: a) providing the flow of the substrate under the action of gravity; b) promote gas exchange between the liquid medium and the atmosphere; c) to establish itself as a means of support biomass and to check the operating conditions and types of blankets to enable wastewater treatment for the removal of carbonaceous matter without the need for artificial aeration. In this study, we analyzed the removal of suspended solids (SS), turbidity, dissolved oxygen, COD and BOD5. The average results of COD removal and BOD in the different operational phases ranged 75-86% and 80 to 86%, respectively. The average concentrations of COD in the final effluent ranged 81-179 mg/L, while the average concentrations of BOD were between 47-97 mg/L. Global average of TSS in the final effluent were maintained on 49 mg/L. To remove turbidity of 92.8%. The PF / BTF (Pre-filter / Biological trickling filter) system can become a very promising alternative for treating sewage from small installations from Brazil, once the system showed low hydraulic retention time and removal efficiency of COD , BOD5 and suspended solids, resulting in a compact installation and low costs. Furthermore, the energy consumption and operating costs are minimal / Mestrado / Saneamento e Ambiente / Mestra em Engenharia Civil
|
23 |
Elaboração de modelo conceitual da degradação de poliacrilamidas (PAM) em compostos nitrogenados aplicado a estudo de caso /Santos, Aline Diorio dos. January 2018 (has links)
Orientador: Chang Hung Kiang / Banca: Rosely Aparecida Liguori Imbernon / Banca: Elias Hideo Teramoto / Resumo: Um dos materiais presentes nos lodos oriundos das estações de tratamento (LETAs) é o polímero denominado Poliacrilamida (PAM). Acredita-se que o mesmo seja inerte no solo, porém sua degradação pode estar associada a presença de compostos nitrogenados no solo, como amônio, nitratos e nitritos. Assim, é essencial avaliar a degradação de polímeros no sistema de tratamento de água que auxiliará na seleção e uso de produtos poliméricos no tratamento de água potável. Através da revisão bibliográfica apresentada neste trabalho, foi elaborado um Modelo Conceitual para a disposição de LETAs em aterro, com enfoque na degradação de poliacrilamidas e sua degradação em compostos nitrogenados, validando-o através de dados observados em estudo de caso. Conforme o Modelo Conceitual elaborado, pela via aeróbia, em que os processos de nitrificação podem ser observados, esperavam-se menores valores de pH (resultado da liberação de íons H+), assim como ambiente oxidante para ocorrência do processo de nitrificação (meio aeróbio necessita de oxigênio disponível), enquanto na área fora da zona de nitrificação, esperava-se maior valores de pH, presença maior de OD e maiores valores de Eh, uma vez que o oxigênio não estará sendo consumido pelas bactérias nitrificantes, podendo ainda haver incremento de OD pela recarga do aquífero através das precipitações. Observa-se outra via de degradação anaeróbia, pela reação anamox, em que amônio é oxidado e nitrito reduzido, liberando gás nitrogênio, em ambient... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: One of the materials present in the sludge originated from water treatment is the polymer polyacrylamide, which some people believes is inert in the soil however its degradation may be associated with nitrogenous compounds in the soil, such as ammonium, nitrates and nitrites. So, it is essential to evaluate the degradation of polymers in the water treatment system due to it will assist in the selection and use of polymer products in the water treatment. Through the bibliographic review presented, a Conceptual Model for the disposition of sludge from water treatment in soil was developed, with the focus on the degradation of polyacrylamides and their degradation in nitrogenous compounds, validating it through data observed in a case study. According to the Conceptual Model elaborated, considering the aerobic route, where the nitrification processes can be observed, were expected lower pH values and oxidizing environment, while in the area outside the nitrification zone were expected higher pH values, presence of dissolved oxygen and reduction environment, once oxygen will not be consumed by nitrifying bacteria and also oxygen could be increased by water from precipitation which recharges the aquifer. Another anaerobic degradation route is observed, considering the anamox reaction, where ammonia is oxidized and nitrite reduced, releasing nitrogen gas, in a reducing environment. In addition, ammonium ion plus manganese oxide plus iron hydroxide can be oxidized to a vapour nitrog... (Complete abstract click electronic access below) / Mestre
|
24 |
Integridade de dados meteorológicos para uso em modelo hidrológico /Carleto, Nivaldo January 2016 (has links)
Orientador: José Eduardo Pitelli Turco / Coorientador: Teresa Cristina Tarle Pisarra / Banca: Vera Lúcia Abdala / Banca: David Luciano Rosalen / Banca: Carlos Eduardo Angeli Furlani / Banca: Anaira Denise Caramelo / Resumo: No Brasil, as Estações Meteorológicas Automáticas (EMA) vêm sendo utilizadas no setor agrícola, em universidades e institutos de pesquisa. Porém, é fundamental garantir a confiabilidade dos dados meteorológicos coletados pelos sensores destas estações. Diante disso, objetivou-se neste trabalho verificar a influência da integridade dos dados (velocidade do vento, radiação solar, temperatura e umidade do ar e precipitação pluviométrica) sobre os parâmetros hidrológicos da Bacia Hidrográfica do Córrego Rico/SP utilizando o modelo SWAT. Os dados foram obtidos por três estações meteorológicas automáticas; uma da Campbell Scientific e outra da Davis Instruments instaladas no Departamento de Engenharia Rural da FCAV/UNESP (Câmpus de Jaboticabal/SP) e uma outra do Sistema Integrado de Dados Ambientais (SINDA) do Instituto Nacional de Pesquisas Espaciais (INPE), localizada próxima ao Departamento de Ciências Exatas da FCAV/UNESP. Foram aplicadas técnicas para verificar a integridade dos dados destas estações e o modelo SWAT para analisar os parâmetros hidrológicos da Bacia Hidrográfica do Córrego Rico/SP. De acordo com os resultados, verificou-se que os dados dos sensores de precipitação, de velocidade do vento, de umidade relativa do ar e de radiação solar da EMA do SINDA/INPE não foram aceitáveis devido à falta de calibração, manutenção e inspeção da estação. Como consequência, houve diferenças significativas nos parâmetros hidrológicos de saída do modelo SWAT, o que compromete o pl... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: In Brazil, Automatic Weather Stations (EMA) have been used in the agricultural sector, universities and research institutes. However, it is essential to ensure the reliability of meteorological data collected by the sensors of these stations. The research objective of this study was to investigate the influence of data integrity (wind speed, solar radiation, temperature and humidity and precipitation) on the hydrological parameters Basin Stream Rico/SP using the SWAT model. The data were obtained for three automatic weather stations; one of Campbell Scientific and another from Davis Instruments installed in the Department of Rural Engineering FCAV/UNESP (Jaboticabal/SP Campus) and another of the Integrated Environmental Data (SINDA) of the National Institute for Space Research (INPE), located near the Department of Exact Sciences FCAV/UNESP. Techniques were applied to verify the integrity of the data from these stations and the SWAT model to analyze the hydrological parameters Basin Stream Rico/SP. According to the results, it was found that the data precipitation sensors, wind speed, relative air humidity, and solar radiation EMA SINDA/INPE were not acceptable due to lack of calibration, maintenance and inspection season. As a result, there were significant differences in the output parameters of the SWAT hydrologic model, which undertakes the planning and management of water and natural resources. / Doutor
|
25 |
Contribuição para estudos das estações ferroviárias paulistas / Contributions from studies São Paulo railway stationsBem, Sueli Ferreira de 07 December 1998 (has links)
Esta dissertação pretende contribuir para ordenação de informações acerca das estações ferroviárias paulistas, ressaltando a importância da ferrovia e da arquitetura produzida no contexto sócio-econômico-cultural do fértil período experimentado por São Paulo e pelo Brasil, durante a segunda metade do século 19 até os anos de 1940, quando o declínio dos negócios ferroviários, processo iniciado décadas antes, torna-se de fato evidente. A sistematização de alguns dados auxilia a compreensão do tema no campo da história da arquitetura e do urbanismo, e também do patrimônio cultural, permitindo ensaios de leitura das estações ferroviárias paulistas quanto a aspectos urbanísticos, especificidade e ineditismo de programa, vínculos com a arquitetura erudita, potencial simbólico dos edifícios e o conteúdo revelado pelo patrimônio construído e ainda existente no território do estado. / This dissertation intends to contribute to organize information about Paulistas railway stations, emphasizing the significance of the railway and the architecture produced in the social-economic-cultural context of the progressive period experienced by São Paulo and Brazil, from the second half of the 19th century until the 1940\'s, when the decline of railway system, a process that started decades before, becomes clear. The systematization of some basic facts helps to understand the subject in the architecture and the urbanism\'s scope and also of the cultural heritage, and to allow essays on the Paulistas railway stations related to the urbanistic aspects, and program\'s novelty, ties with the investigations of the formal architecture, symbolic potencial of the buildings and the contents revealed by the built heritage yet existent in the state of São Paulo.
|
26 |
Positividade para o vírus da raiva em morcegos no Estado de São Paulo e potenciais fatores de risco /Favaro, Ana Beatriz Botto de Barros da Cruz. January 2018 (has links)
Orientador: Luzia Helena Queiroz / Coorientador: Márcia Marinho / Banca: Cáris Maroni Nunes / Banca: Rafael Silva Cipriano / Resumo: A raiva é uma antropozoonose caracterizada por uma encefalomielite aguda, na grande maioria dos casos letal, com grandes impactos na saúde pública, economia e na medicina veterinária. No Brasil o número de casos de raiva transmitido por morcegos vem superando a transmissão por cães, representando um novo cenário epidemiológico desta zoonose. Objetivamos analisar o índice de positividade da raiva em morcegos, segundo as variáveis hábito alimentar, classificação taxonômica, sexo e estação do ano com o intuito de identificar possíveis fatores de risco para ocorrência da raiva em morcegos. Por meio da análise retrospectiva de registros de 10.362 amostras de mamíferos dos Laboratórios de Diagnóstico de Raiva e de Chiroptera da Unesp de Araçatuba, do período de 1998 a 2017, foram identificadas 6.389 amostras provenientes de quirópteros que foram submetidos ao diagnóstico de raiva e à identificação taxonômica. Obtivemos resultado positivo em 76 (1,1%) das amostras de quirópteros, provenientes de 10 espécies, dentre as 31 que foram enviadas, representando sete gêneros de três famílias. O perfil dos morcegos positivos para a raiva na região estudada foi caracterizado como insetívoros e frugívoros, pertencentes à família Vespertilionidae e gênero Myotis e Eptesicus. A época do ano com maior identificação do vírus da raiva em quirópteros foi a estação mais seca (entre os meses de maio a setembro). / Abstract: Rabies is an anthropozoonosis characterized by acute encephalomyelitis, which is lethal in the vast majority of the cases and has major impacts on public health, economy and veterinary medicine. In Brazil, the number of rabies cases transmitted by bats has been surpassing the transmission by dogs, representing a new epidemiological scenario for this zoonosis. The objective of this study was to analyze the positivity rate of rabies in bats, according to the variables alimentary habits, taxonomic classification, sex and season of the year, in order to identify possible risk factors for rabies occurrence in bats. A retrospective analysis of the records from Rabies and Chiroptera Diagnostic Laboratories of Araçatuba, from 1998 to 2017, identified 6,389 samples from Chiroptera that were submitted to rabies diagnosis and taxonomic identification. We observed positive result in 76 (1.1%) of the bats samples, from 10 species, out of the 31 that were sent, representing seven genera of three families. Thus, the profile of positive bats for rabies in the studied region was characterized as insectivorous and frugivorous, belonging to the family Vespertilionidae, and genus Myotis and Eptesicus. The time of year with the highest identification of the rabies virus in bats was during the dry seeson (between May and September). / Mestre
|
27 |
Estratégias de gestão de lamas das estações de tratamento de águas residuais (ETAR) : estrusão de lamas para aplicação na agriculturaSousa, Ricardo José Vieira de January 2005 (has links)
Tese de mestrado. Engenharia do Ambiente (Ramo de Gestão e Tratamento de Resíduos Industriais). Faculdade de Engenharia. Universidade do Porto. 2005
|
28 |
Acompanhamento do arranque/exploração de uma ETARCerdeira, Lara Alexandra Brioso Moreno January 2008 (has links)
Estágio realizado na EFACEC-Ambiente e orientado pelo Eng.ª Isabel saraiva e Eng.ª Maria Amélia Fonseca / Tese de mestrado integrado. Engenharia Química. Faculdade de Engenharia. Universidade do Porto. 2008
|
29 |
Estudo das emissões gasosas por processos de desodorizaçãoSousa, Vera Mónica Almeida de January 2009 (has links)
Estágio realizado na EFACEC Ambiente, S. A. e orientado pelo Eng.ª Amélia Fonseca / Tese de mestrado integrado. Engenharia Química. Faculdade de Engenharia. Universidade do Porto. 2009
|
30 |
Eficiência económica numa instalação elevatóriaMachado, André de Castro January 2008 (has links)
Tese de mestrado integrado. Engenharia Civil (especialização em Hidráulica). Faculdade de Engenharia. Universidade do Porto. 2008
|
Page generated in 0.0268 seconds