• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 108
  • 20
  • 4
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 406
  • 406
  • 225
  • 213
  • 201
  • 189
  • 181
  • 134
  • 67
  • 52
  • 49
  • 42
  • 38
  • 37
  • 35
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

"The future of football is feminine" : a critical cultural history of the U.S. women's national soccer team

Narcotta-Welp, Eileen Marie 01 August 2016 (has links)
“The Future of Football is Feminine”: A Critical Cultural History of the U.S. Women’s National Soccer Team,focuses on the historical and cultural construction of the U.S. women’s national soccer team. The public and academic discourse that constitutes women’s soccer in the U.S. consistently links the game with the feminist legislation of Title IX, and positions male coaches as benevolent patriarchs who grant young girls and women the right to play. The combination of these two dominant narratives confronts the historical narrative of women’s soccer from an uncritical and celebratory space, which represses and decenters lines of power. I challenge these steadfast discourses by locating this team, and thus, women’s soccer, in the larger cultural frame of neoliberal, postfeminist, post-racial, and sexual politics. Through an examination of U.S. newspapers and magazines, United States Soccer Federation (USSF) and Fédération Internationale de Football Association (FIFA) documents, and extensive soccer-specific journals and magazines, I explore the intersection of capitalism, feminism, and racism in women’s professional sport. This research also examines how the media and other corporations have cultivated the U.S. women’s national team and its individual stars, such as Mia Hamm, Brandi Chastain, Kristine Lilly, Abby Wambach, and Hope Solo to promote themselves as consumer conduits through which moral and ethical behaviors circulate and influence civil society. Since the mid-1990s, young female soccer players find themselves at an ideological crossroad of individual choice and self-discipline. The soccer field has been promoted as a space of gender and racial inclusion as well as economic and political freedom while subtly reinforcing the exact opposite. Moreover, I examine the historical and ever-shifting landscape of women’s soccer, and how neoliberalism as an economic and cultural theory is central to the use of race, class, gender, and sexual ideologies to develop women’s soccer in the United States.
82

Understanding health through the eyes of rural adolescents

Morrissey, Joanna Lynn 01 May 2012 (has links)
The purpose of this study was to develop a theory grounded in the health experiences of rural adolescents. By exploring the embodied experiences within a unique population of rural Iowan adolescents, many who are overweight/obese and/or of Hispanic descent, the developed theory was also used to inform a tailored health intervention for middle school students. The review of the literature revealed that the study of adolescent physical activity and body image concerns is largely measurement driven, and often explored from a deficit perspective. Thus, there remains a gap in the literature regarding the contextualized experience of health. This project used a qualitative approach to generate a theory grounded in stories adolescents shared regarding their health. Eighteen adolescents (13-15 years old) participated in one-on-one interviews. Grounded theory principles were used to understand how personal health experiences were socially constructed and explored the meanings participants derived from such experiences. An unstructured interview guide was used to gather information on health, physical activity, nutrition, and body image. The interviews were transcribed verbatim and analyzed using Charmaz's (2006) version of grounded theory. A total of 28 codes emerged from the data to construct the Theory of Embodied Health and Wellness. The complex interplay of personal health behaviors, eco-sociocultural influence, and everyday experience mold adolescents' embodied health and wellness experiences. Participants reported a wide range of personal, social, cultural and environmental influences on their health experiences. Feeling in control, connected, and competent were major themes in how participants experienced, maintained, or challenged their health experiences within their sociocultural environment. In addition to constructing the Theory of Embodied Health and Wellness, this project engaged adolescents in conversations related to their own health experiences to develop a sociocultural tailored health intervention. This project provides a practical example of how the target population of an intervention can be included during the formative research phase to ensure the intervention is tailored to meet their needs and interests.
83

A prospective, 3-year follow-up study of vascular function and cardiac autonomic control following renal transplantation

Ferrante, Kimberly 01 July 2012 (has links)
No description available.
84

The Hypertrophic Effects of Practical Vascular Blood Flow Restriction Training

O'halloran, John Francis 27 March 2014 (has links)
Practical blood flow restriction training is a new training technique that has the potential to increase muscular hypertrophy and muscular strength while allowing practitioners to train with lighter loads (20-30% of 1-RM). Through the use of elastic knee wraps, the limbs can be restricted using a perceived pressure scale. The comparison of practical blood flow resistance training with traditional, non-blood flow restricted resistance training and its effects on muscular hypertrophy and strength has not been investigated. Twenty-one resistance-trained males participated in a 4-week training program and were randomly assigned to one of two groups: Practical BFR training (BFR; n = 10) and Resistance training (RT; n = 11). The primary difference between the groups was the BFR group performed approximately 62% of all sets blood flow restricted at 20-30% of 1-RM while the RT group performed all sets at an intensity of > 70% 1-RM in a traditional manner (non-blood flow restricted). Perceived pressure for blood flow restriction in the BFR group for the arms and legs was 7 out of 10. Workouts for both groups were similar and consisted of whole body routines ~3 days/week. A 2x2 repeated measures ANOVA was used to assess group, time, and group by time interactions. Statistical significance was set to p ≤ 0.05. There was a no difference in total lifting volume with the BFR group achieving a total lifting volume that was 11% less than the RT group. There was a main effect for time for biceps cross-sectional area (p = 0.004), thigh girth (p = 0.002), bench press 1RM (p = 0.001) and leg press 1RM (p < 0.001). Specifically, BFR improved from 220.5 ± 65.1 to 235.0 ± 50.6 pounds and from 822 ± 135.9 to 952.5 ± 168.9 pounds in the bench press and leg press, respectively. The RT improved from 245.9 ± 60.9 to 257.7 ± 53.5 pounds and from 780.5 ± 192.4 to 957.3 ± 213.4 pounds in the bench press and leg press, respectively. No interaction effects were observed for all hypertrophy and strength variables. 4-weeks of practical blood flow restriction training is as effective for inducing maximal bench press and leg press strength, as well as biceps muscle size and thigh muscle size, as compared to traditional resistance training, despite training at low percentages of subjects 1-RM.
85

Some physiological changes in female athletes during and after exercise : investigating the use of a new, low-invasive sampling method (electrosonophoresis) : a thesis in partial fulfilment of the requirements for the degree of Master of Science in Exercise Physiology at Massey University, Palmerston North, New Zealand

Purnell, Heather Margaret Unknown Date (has links)
The purpose of this study was to monitor cardiovascular and endocrine changes in sedentary and training females during a six week period, and to assess the accuracy of a new, low-invasive sampling methodology (electrosonophoresis). Changes in fitness were measured using oxygen consumption (VO2). The impact on VO2 of sleep quality, sleep duration and alcohol consumption (recorded in sleep logs) was assessed. Cortisol, testosterone and growth hormone levels in plasma were monitored for acute changes following fitness tests, and chronic changes related to training, oral contraceptive use or alcohol consumption. Hormone concentrations in blood and saliva samples were compared to those in interstitial fluid (obtained using electrosonophoresis) to investigate the accuracy of electrosonophoresis. Mean VO2 increased by 3.3 ± 1.3mL/kg/min between Week 1 and Week 5 and the changes detected in heart rate (HR) during the fitness tests suggest that aerobic fitness of the training participants increased across the study. No significant associations between sleep quality, sleep duration or alcohol consumption and VO2 were detected. No acute changes in plasma hormone concentrations following fitness tests were detected. No chronic changes in plasma cortisol or testosterone concentrations were detected, although a non-significant trend towards increased plasma GH levels in training participants was detected. Resting plasma cortisol levels were significantly lower in oral contraceptive users compared with non-users. Plasma testosterone and growth hormone levels were unaffected by oral contraceptive use. Alcohol consumption had no acute detectable effects on plasma concentrations of the three hormones. Plasma testosterone levels were higher in participants who abstained from alcohol, and higher plasma growth hormone levels were detected in heavy drinkers. These results contrast with published reports. Concentrations of the three hormones in interstitial fluid and plasma exhibited highly significant positive correlations (r2 > 0.98) with an interstitial fluid:plasma concentration ratio of about 1:10 in each case. Equations to predict plasma concentrations of cortisol, testosterone and growth hormone from interstitial fluid concentrations have been derived. The electrosonophoretic method apparently provides an accurate, painless, low-invasive method for prediction of the plasma levels of these three hormones. This technology has far-reaching implications for research in human, animal and biomedical fields.
86

A Comparison of Commonly Used Accelerometer Based Activity Monitors in Controlled and Free-Living Environment

Feito, Yuri 01 December 2010 (has links)
This dissertation was designed to determine the effects of body mass index (BMI) and walking speed on activity monitor outputs. A secondary purpose was to compare the activity monitors’ performance in a free-living environment. In the first experiment, 71 participants wore three waist-mounted activity monitors (Actical, ActiGraph, and NL-2000) and an ankle-mounted device (StepWatch 3) while walking on a treadmill (40, 67 and 94 m/min). The tilt angle of each device was measured. The Actical recorded 26% higher activity counts (P < 0.01) in obese persons with a tilt <10 degrees, compared to normal weight persons. The ActiGraph was unaffected by BMI or tilt angle. In the second experiment, the steps recorded by the devices were compared to actual steps. Speed had the greatest influence on the accuracy these devices. At 40 m/min, the ActiGraph was the least accurate device for normal weight (38%), overweight (46%) and obese (48%) individuals. The Actical, NL-2000 and StepWatch averaged 65%, 73% and 99% of steps taken, respectively. Lastly, several generations of the ActiGraph (7164, GT1M, and GT3X), and other research grade activity monitors (Actical; ActivPAL; and Digi-Walker) were compared to a criterion measure of steps. Fifty-six participants performed treadmill walking (40, 54, 67, 80 and 94 m/min) and wore the devices for 24-hours under free-living conditions. BMI did not affect step count accuracy during treadmill walking. The StepWatch, PAL, and the AG7164 were the most accurate across all speeds; the other devices were only accurate at the faster speeds. In the free-living environment, all devices recorded about 75% of StepWatch-determined steps, except the AG7164 (99%). Based on these findings, we conclude that BMI does not affect the output of these activity monitors. However, waist-borne activity monitors are highly susceptible to under-counting steps at walking speeds below 67 m/min, or stepping rates below 100 steps/min. An activity monitor worn on the ankle is less susceptible to these speed effects and provides the greatest accuracy for step counting.
87

Accuracy of Physical Activity Monitors in Pregnant Women

Connolly, Christopher P 01 May 2010 (has links)
Purpose: To determine the step count accuracy of three pedometers and one accelerometer in pregnant women during treadmill walking. Methods: Subjects were 30 women in the second or third trimester (20-36 weeks) who were screened for pregnancy-related risk factors. Each subject was fitted with a belt containing three physical activity monitors: Yamax Digiwalker SW-200 (DW), New Lifestyles NL 2000 (NL), and GT3X Actigraph accelerometer (ACT). The Omron HJ-720 (HJ) was placed in the pants pocket. Subjects walked at 54, 67, 80, and 94 m•min-1 for two minutes each. Actual steps were determined by an investigator using a hand-tally counter. Percentage of actual steps was calculated for each device at each speed and compared. Results: There was a significant interaction between speed and device (F9,20=7.574,P<0.001). At all speeds, the NL and HJ were most accurate. At 54 m•min-1, the DW was significantly less accurate (P<0.001) than all other devices and the ACT was significantly less accurate (P<0.001) than the NL and HJ. At 67 m•min-1, the ACT and DW were significantly less accurate (P<0.001) than the NL and HJ. At 80 m•min-1, the DW was significantly less accurate (P=0.024) than the NL and HJ. At 94 m•min-1, the ACT was significantly less accurate (P=0.001) than the NL and HJ. No significant differences were found at any speed for the NL (P=0.996) and HJ (P=0.298). Trimester did not significantly affect device accuracy. Conclusion: In pregnant women, the ACT and DW are less accurate than the NL and HJ. The HJ appeared to be the most accurate. These results can be useful in developing further research studies and physical activity programs that focus on walking during pregnancy.
88

Accuracy of Physical Activity Monitors in Pregnant Women

Connolly, Christopher P 01 May 2010 (has links)
Purpose: To determine the step count accuracy of three pedometers and one accelerometer in pregnant women during treadmill walking. Methods: Subjects were 30 women in the second or third trimester (20-36 weeks) who were screened for pregnancy-related risk factors. Each subject was fitted with a belt containing three physical activity monitors: Yamax Digiwalker SW-200 (DW), New Lifestyles NL 2000 (NL), and GT3X Actigraph accelerometer (ACT). The Omron HJ-720 (HJ) was placed in the pants pocket. Subjects walked at 54, 67, 80, and 94 m•min-1 for two minutes each. Actual steps were determined by an investigator using a hand-tally counter. Percentage of actual steps was calculated for each device at each speed and compared. Results: There was a significant interaction between speed and device (F9,20=7.574,P<0.001). At all speeds, the NL and HJ were most accurate. At 54 m•min-1, the DW was significantly less accurate (P<0.001) than all other devices and the ACT was significantly less accurate (P<0.001) than the NL and HJ. At 67 m•min-1, the ACT and DW were significantly less accurate (P<0.001) than the NL and HJ. At 80 m•min-1, the DW was significantly less accurate (P=0.024) than the NL and HJ. At 94 m•min-1, the ACT was significantly less accurate (P=0.001) than the NL and HJ. No significant differences were found at any speed for the NL (P=0.996) and HJ (P=0.298). Trimester did not significantly affect device accuracy. Conclusion: In pregnant women, the ACT and DW are less accurate than the NL and HJ. The HJ appeared to be the most accurate. These results can be useful in developing further research studies and physical activity programs that focus on walking during pregnancy.
89

Field based testing protocols to monitor training adaptations and performance in elite rowers.

Vogler, Andrew James, avogler@virginbroadband.com.au January 2010 (has links)
Laboratory-based rowing tests are the established standard for assessing fitness traits among elite rowers, and for prescribing individualised exercise intensities for training. But because tests occur on a rowing ergometer, the specificity of laboratory testing has been questioned compared with the criterion of on-water rowing. This project validated equipment required to replicate a laboratory-based rowing test in the field and evaluated the feasibility of on-water tests. Ergometer and on-water test results were compared to assess the validity of ergometer-derived training prescriptions and to establish the effectiveness of on-water tests for monitoring longitudinal fitness changes and for predicting rowing performance. Concept2 rowing ergometers (Morrisville, USA) have frequently been used for rowing tests. Although subtle design variations exist between the different models of Concept2 ergometer, there were no substantial differences between the results from incremental rowing tests using Model C and Model D ergometers. The Concept2 Model D was therefore accepted as the standard ergometer for subsequent laboratory tests. Typical error (TE) results from duplicate Concept2 Model D tests conducted 2-4 d apart showed that laboratory tests were highly reliable (TE: maximal power = 2.8%, peak oxygen consumption = 2.5%). As oxygen consumption (VO2) is measured routinely during laboratory rowing tests, it is necessary to obtain similar measurements during any on-water protocol. The MetaMax 3B portable indirect calorimetry system (Cortex, Leipzig, Germany) was therefore validated against a first-principles, laboratory-based indirect calorimetry system (MOUSe, Australian Institute of Sport, Canberra, Australia). VO2 from the MetaMax was significantly higher during submaximal exercise (p=0.03), although results were within 0.16 L.min-1 (4.1%) across all exercise intensities. There was good agreement between duplicate MetaMax trials separated by ~2 d; mean VO2 was within 0.11 L.min-1 (2.5%) and TE was ¡Ü2.3%. The specificity of rowing testing was improved using an On-water incremental test that replicated a laboratory-based Ergometer protocol. However, the individual variation in physiological responses between-tests meant that training intensity recommendations from the Ergometer test were not always applicable to on-water training. Furthermore, measurements from the On-water protocol displayed similar or lesser reliability (TE=1.9-19.2%) compared with the Ergometer test (TE=0.1-11.0%). As an effective fitness test must also be sensitive to longitudinal changes, the responses to 6 wks training were compared between the Ergometer and On-water methods. The magnitude of On-water training effects were usually greater (small Cohen¡¯s effect size) compared with the Ergometer test (trivial effect), although On-water and Ergometer tests both indicated that training responses were negligible because virtually all changes were less than one of their respective TEs. Correlations between test results and rowing performance were largest when rowing mode was matched between conditions, but Ergometer results provided the highest correlations (Ergometer vs. 2000-m ergometer time-trial: R= -0.92 to -0.97 compared with On-water vs. On-water maximal power output: R=0.52 to 0.92). Although On-water tests improved the specificity of on-water training prescriptions, these tests provided no obvious benefits for monitoring longitudinal fitness changes or performance compared with Ergometer tests. Given that On-water tests are also more time consuming and logistically challenging, their practical application is limited.
90

Temperature regulation, physical stress, and immune system: An interactive approach in the military environment

Lim, C. L. Unknown Date (has links)
No description available.

Page generated in 0.0664 seconds