• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudo experimental do uso do vidro bioativo com implantes imediatos em cirurgia para levantamento da membrana sinusal. Análises histológica, histomorfométrica e imunoistoquímica /

Cervantes, Lara Cristina Cunha. January 2019 (has links)
Orientador: Idelmo Rangel Garcia Júnior / Banca: Francisley Ávila Souza / Banca: André Luís Da Silva Fabris / Resumo: A proposta deste estudo foi avaliar o processo de regeneração óssea com o uso do biomaterial Biogran®, um vidro bioativo, como uma opção de substituto ósseo para técnicas de enxerto em levantamento do assoalho do seio maxilar através de análises histológica e histomorfométrica. Para tal, 24 coelhos da raça Nova Zelândia foram submetidos ao procedimento de levantamento do seio maxilar bilateralmente, sendo divididos em dois grupos: grupo coágulo implante (GCI), no qual foi realizado o levantamento do seio maxilar, seguindo implante imediato, sem enxerto; e o grupo biovidro implante (GBI), no qual foi realizado o levantamento do seio maxilar, preenchimento com Biogran® e instalação de implante imediata. Os animais foram submetidos à eutanásia aos 7, 15 e 40 dias. A análise histológica mostrou no grupo GCI uma formação de tecido ósseo gradual, sendo maior aos 40 dias, com característica lamelar. Porém, não apresentava diferença estatística entre os períodos de 15 e 40 dias de eutanásia (p=0,210). O grupo GBI revelou uma formação de tecido ósseo mais tardia, com maior quantidade aos 40 dias, com reabsorção lenta e progressiva dos grânulos do biomaterial e sinais indicativos de atividade osteoblástica. Este grupo mostrou diferença estatística entre os períodos de 7 e 15 dias quando comparados aos 40 dias (p<0,05). Na análise intergrupos, não houve diferença estatisticamente significante aos 7 e aos 40 dias, mas sim, aos 15 dias. Dessa forma, pode-se concluir que o Biogran® é um bi... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The purpose of this study was to evaluate the bone regeneration process with the use of the Biogran® biomaterial, a bioactive glass, as a bone substitute option for grafting techniques in the maxillary sinus floor through histological and histomorphometric analysis. To that end, 24 New Zealand rabbits underwent a bilateral maxillary sinus removal procedure, and were divided into two groups: an implant clot group (ICG), in which the maxillary sinus was removed, followed by immediate implantation without graft ; and the implant bioglass group (GBI), in which the maxillary sinus was removed, filled with Biogran® and implanted in the immediate implant. The animals were submitted to euthanasia at 7, 15 and 40 days. The histological analysis showed a formation of gradual bone tissue in the GCI group, being larger at 40 days, with a lamellar characteristic. However, there was no statistical difference between the periods of 15 and 40 days of euthanasia (p = 0.210). The GBI group revealed a later bone formation with a greater amount at 40 days, with slow and progressive resorption of the biomaterial granules and signs indicative of osteoblastic activity. This group showed statistical difference between the periods of 7 and 15 days when compared to the 40 days (p <0.05). In the intergroup analysis, there was no statistically significant difference at 7 and 40 days, but at 15 days. Thus, it can be concluded that Biogran® is a biomaterial with osteoconductive properties, of slow resorpt... (Complete abstract click electronic access below) / Mestre
2

Estudo experimental comparativo de remendos arteriais de polidimetilsiloxano com reforço de tecido de poliéster (PDMSr) versus politetrafluoretileno expandido (PTFEe) em aorta de coelhos / Patch of polydimethylsiloxane reinforced with polyester fabric for aortic angioplasty in rabbits

Sassaki Neto, Paulo Isao 15 October 2014 (has links)
Introdução: Apesar de bons resultados descritos na literatura, o substituto ideal para a utilização como remendo no fechamento arterial ainda não existe. Por este motivo, ainda há espaço para a busca por remendo que seja biocompatível, e que apresente facilidade de manuseio e resultados satisfatórios. Avaliamos remendos arteriais de silicone (polidimetilsiloxano com reforço em poliéster - PDMSr) em comparação com remendos arteriais de PTFEe. Objetivo: O objetivo deste trabalho é comparar, em modelo experimental, em coelhos, os resultados de remendos arteriais feitos em PDMSr com remendos de PTFEe. Materiais e Método: A amostra foi definida em 10 animais que completassem todas as etapas da pesquisa em cada grupo. Os animais foram submetidos à laparotomia mediana e abertura longitudinal da aorta de aproximadamente 8mm, realizando-se o seu fechamento com remendo do grupo selecionado, seguido do fechamento por planos. Os animais foram mantidos em biotério até o 60º PO, quando, então, realizou-se arteriografia de controle, e análise macro e microscópica de peça. Resultados: Para se atingir a amostra desejada, foram necessários 12 procedimentos no grupo PDMSr e 16 no grupo PTFEe. Ocorreram 2 óbitos no grupo PDMSr e 6 no grupo PTFEe. Apesar do número maior de óbitos no grupo PTFEe não houve diferença estatística na sobrevida entre os grupos. Um animal do grupo PDMSr apresentou monoparesia em pata posterior direita e um animal do grupo PTFEe apresentou hérnia incisional. Não houve diferença estatística nas complicações entre os grupos. O tempo operatório foi estatisticamente maior no grupo PTFEe quando comparamos todos os animais, fato que não se repetiu quando excluímos os animais que faleceram. O peso e o tempo operatório foram estatisticamente maiores nos animais que morreram. Todos os animais que chegaram ao final do tempo de estudo apresentavam aorta patente. Na análise macroscópica da peça, houve, estatisticamente, maior reação tecidual periprótese no grupo PTFEe. A microscopia eletrônica de varredura evidenciou cobertura de todo o remendo de PDMSr por tecido similar ao endotélio, enquanto, nos remendos de PTFEe, o crescimento limitou-se às bordas da linha de sutura e ilhas isoladas no seu centro. Conclusão: O material estudado apresentou resultados comparáveis ao do PTFEe, porém com menor reação tecidual local e maior proliferação celular para a luz do vaso. Apesar de novos estudos serem necessários, inclusive para avaliação de uso em humanos, o presente estudo apresenta resultados promissores que encorajam a continuidade de sua pesquisa / Introduction: Although good results are reported for various materials for use as patches for arterial closure, as yet none of these is ideal. Therefore, research is continuing into development of a patch that is biocompatible and provides ease of handling, while having satisfactory outcomes. A new silicone arterial patch (polydimethylsiloxane reinforced with polyester fabric, PDMSr) was compared with patches made of expanded polytetrafluoroethylene (ePTFE). Objective: To compare the outcomes between arterial patches made of PDMSr with those made of ePTFE, in an experimental rabbit model. Materials and Method: Rabbits were placed in two groups, and received either PDMSr or ePTFE arterial patches (PDMSr group and ePTFE group, respectively). The animals underwent laparotomy and longitudinal opening of the aorta, which was then closed with the selected patch, followed by suture of all layers. The animals were kept in their cages until the 60th postoperative day, when arteriography, removal of the aorta, and macroscopic and optic and scanning electron microscopic analyzes of the aorta were performed. Ten rabbits from each group that had completed all stages of the research were included in analyses. Results: Twelve procedures were performed in the PDMSr group and 16 in the ePTFE group. There were 2 deaths in the PDMSr group and 6 in the ePTFE group. Despite the higher number of deaths in the ePTFE group, there was no statistical difference in survival rate between the groups. One animal in the PDMSr group developed monoparesis in its right hind paw and 1 animal in the ePTFE group had an incisional hernia. There was no statistical difference in complications between the groups. The operative time was significantly longer in the ePTFE group when all animals were included in analysis, but not when animals that died were excluded. Body weight was significantly greater and operative time was significantly longer in animals that died. Postsurgical aortic patency in the survival animals was 100% in both groups by arteriography. Macroscopically, tissue reaction around the prosthesis was greater in the ePTFE group (statistically significant). Microscopically, the PDMSr patches were entirely covered with a cellular endothelium-like tissue, while tissue growth on the ePTFE patches was limited to the edges of the suture line and to isolated central islands. Conclusion: The two materials showed comparable outcomes; however, PDMSr showed cellular proliferation to the entire graft, and less local inflammatory reaction compared with ePTFE. Although further studies are required, including assessment in humans, the results of the present study indicate that PDMSr shows promise as an arterial patch material
3

Estudo experimental comparativo de remendos arteriais de polidimetilsiloxano com reforço de tecido de poliéster (PDMSr) versus politetrafluoretileno expandido (PTFEe) em aorta de coelhos / Patch of polydimethylsiloxane reinforced with polyester fabric for aortic angioplasty in rabbits

Paulo Isao Sassaki Neto 15 October 2014 (has links)
Introdução: Apesar de bons resultados descritos na literatura, o substituto ideal para a utilização como remendo no fechamento arterial ainda não existe. Por este motivo, ainda há espaço para a busca por remendo que seja biocompatível, e que apresente facilidade de manuseio e resultados satisfatórios. Avaliamos remendos arteriais de silicone (polidimetilsiloxano com reforço em poliéster - PDMSr) em comparação com remendos arteriais de PTFEe. Objetivo: O objetivo deste trabalho é comparar, em modelo experimental, em coelhos, os resultados de remendos arteriais feitos em PDMSr com remendos de PTFEe. Materiais e Método: A amostra foi definida em 10 animais que completassem todas as etapas da pesquisa em cada grupo. Os animais foram submetidos à laparotomia mediana e abertura longitudinal da aorta de aproximadamente 8mm, realizando-se o seu fechamento com remendo do grupo selecionado, seguido do fechamento por planos. Os animais foram mantidos em biotério até o 60º PO, quando, então, realizou-se arteriografia de controle, e análise macro e microscópica de peça. Resultados: Para se atingir a amostra desejada, foram necessários 12 procedimentos no grupo PDMSr e 16 no grupo PTFEe. Ocorreram 2 óbitos no grupo PDMSr e 6 no grupo PTFEe. Apesar do número maior de óbitos no grupo PTFEe não houve diferença estatística na sobrevida entre os grupos. Um animal do grupo PDMSr apresentou monoparesia em pata posterior direita e um animal do grupo PTFEe apresentou hérnia incisional. Não houve diferença estatística nas complicações entre os grupos. O tempo operatório foi estatisticamente maior no grupo PTFEe quando comparamos todos os animais, fato que não se repetiu quando excluímos os animais que faleceram. O peso e o tempo operatório foram estatisticamente maiores nos animais que morreram. Todos os animais que chegaram ao final do tempo de estudo apresentavam aorta patente. Na análise macroscópica da peça, houve, estatisticamente, maior reação tecidual periprótese no grupo PTFEe. A microscopia eletrônica de varredura evidenciou cobertura de todo o remendo de PDMSr por tecido similar ao endotélio, enquanto, nos remendos de PTFEe, o crescimento limitou-se às bordas da linha de sutura e ilhas isoladas no seu centro. Conclusão: O material estudado apresentou resultados comparáveis ao do PTFEe, porém com menor reação tecidual local e maior proliferação celular para a luz do vaso. Apesar de novos estudos serem necessários, inclusive para avaliação de uso em humanos, o presente estudo apresenta resultados promissores que encorajam a continuidade de sua pesquisa / Introduction: Although good results are reported for various materials for use as patches for arterial closure, as yet none of these is ideal. Therefore, research is continuing into development of a patch that is biocompatible and provides ease of handling, while having satisfactory outcomes. A new silicone arterial patch (polydimethylsiloxane reinforced with polyester fabric, PDMSr) was compared with patches made of expanded polytetrafluoroethylene (ePTFE). Objective: To compare the outcomes between arterial patches made of PDMSr with those made of ePTFE, in an experimental rabbit model. Materials and Method: Rabbits were placed in two groups, and received either PDMSr or ePTFE arterial patches (PDMSr group and ePTFE group, respectively). The animals underwent laparotomy and longitudinal opening of the aorta, which was then closed with the selected patch, followed by suture of all layers. The animals were kept in their cages until the 60th postoperative day, when arteriography, removal of the aorta, and macroscopic and optic and scanning electron microscopic analyzes of the aorta were performed. Ten rabbits from each group that had completed all stages of the research were included in analyses. Results: Twelve procedures were performed in the PDMSr group and 16 in the ePTFE group. There were 2 deaths in the PDMSr group and 6 in the ePTFE group. Despite the higher number of deaths in the ePTFE group, there was no statistical difference in survival rate between the groups. One animal in the PDMSr group developed monoparesis in its right hind paw and 1 animal in the ePTFE group had an incisional hernia. There was no statistical difference in complications between the groups. The operative time was significantly longer in the ePTFE group when all animals were included in analysis, but not when animals that died were excluded. Body weight was significantly greater and operative time was significantly longer in animals that died. Postsurgical aortic patency in the survival animals was 100% in both groups by arteriography. Macroscopically, tissue reaction around the prosthesis was greater in the ePTFE group (statistically significant). Microscopically, the PDMSr patches were entirely covered with a cellular endothelium-like tissue, while tissue growth on the ePTFE patches was limited to the edges of the suture line and to isolated central islands. Conclusion: The two materials showed comparable outcomes; however, PDMSr showed cellular proliferation to the entire graft, and less local inflammatory reaction compared with ePTFE. Although further studies are required, including assessment in humans, the results of the present study indicate that PDMSr shows promise as an arterial patch material

Page generated in 0.0863 seconds