• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Solução salina versus solução de heparina na perviedade do cateter venoso periférico na terapia venosa intermitente: revisão sistemática / Saline solution versus heparin in the patency of the venous peripheral catheter in the intermittent venous therapy: a systematic review

Ferrari, Adriana Aparecida Constantini 10 February 2017 (has links)
O uso do cateter venoso periférico intermitente em pacientes hospitalizados pode lhes trazer grandes benefícios, proporcionando maior liberdade com a higiene pessoal, alimentação, deambulação, além melhorias para a equipe de enfermagem com redução das rotinas diárias. No entanto, obstrução do cateter é algo que vem na contramão de uma assistência adequada, causando desconforto para o paciente e aumento do trabalho de enfermagem. Para evitar tal evento e garantir a perviedade do cateter intravascular, deve-se realizar o flushing com solução salina ou solução de heparina, após a administração de medicamentos ou em horários programados de acordo com o protocolo interno das instituições de saúde. Nesse contexto, surge o questionamento de qual é a melhor solução para manter a perviedade do cateter venoso periférico intermitente. Este estudo trata-se de uma revisão sistemática da literatura, com o objetivo de avaliar a efetividade do uso da solução salina comparada à solução de heparina na manutenção da perviedade dos cateteres venosos periféricos. Foi realizada a busca nas bases de dados eletrônicas Cinahl, Cochrane Central, Embase, Lilacs, Pubmed e Web of Science. Das 372 referências identificadas, 12 estudos foram selecionados após a análise de título e resumo para serem lidos na íntegra, sendo que 04 constituíram a amostra final. A extração e análise dos dados foram realizadas por dois revisores independentes e as divergências entre eles foram solucionadas por um terceiro revisor. Os 04 estudos foram publicados no período de 1995 a 2015. Ao todo, foram investigados 975 dispositivos endovenosos mantidos com uma das soluções estudadas em 420 participantes. Os estudos testaram a solução de heparina em dosagens que variaram de 10UI/mL a 100UI/mL versus a solução salina e investigaram as complicações relacionadas ao cateter venoso periférico em uso intermitente, sendo uma delas a obstrução do cateter a qual denominamos como ausência e/ou diminuição da perviedade do cateter venoso, que pode ser evitada com o flushing de forma adequada. As intervenções foram testadas em diferentes populações e não foram concordantes em suas conclusões; dois estudos recomendaram a solução de heparina, um estudo, a solução salina, e um recomenda o uso das duas soluções. Os quatro estudos discutem que as duas soluções são seguras e eficazes para a manutenção da perviedade do cateter venoso periférico. Porém, os autores afirmam que o tamanho da amostra não é suficiente para generalizar os resultados para todos os pacientes hospitalizados. Assim, essa revisão sistemática sugere a necessidade de que novos ensaios clínicos randomizados sejam realizados e que as instituições de saúde devem fomentar as investigações clínicas para validar uma assistência de enfermagem alicerçada em práticas seguras e de qualidade / The using of intermittent peripheral venous catheter in a hospitalized patient can bring to them important benefits, providing more freedom concerning to the personal hygiene, feeding, ambulation, and a lot of another improvements for the nursing team, reducing the daily routines. However, catheter obstruction it is something that disturb an appropriate assistence, provoking discomfort to the patient and increasing the need of job of the nursing team. To avoid this fact and to ensure the patency of the intervascular catheter, must to do the flushing process with saline solution or hepamin, after the application of drugs or in pre established time according to the protocol of procedure of the health institutions. In this regard, it emerges the questioning about what is the best solution to keep the patency of the intermittent peripheral venous catheter. This research is a systematic review about the litetature on this subject, and it aims to evaluate the effectiveness of the using of the saline solution in comparison to the heparin in the maintenance of the patency of the peripheral venous catheter. It has been done a research in the electronic databases Cinahl, Cochrane Central, Embase, Lilacs, Pubmed and Web of Science. An amount of 372 references was identified, but just 12 research were selected after the analysis of their titles and abstracts to be fully read. In the end, 04 of them were picked as definitive samples.The data collect and the anlysis were done by two independent reviewers, and the divergences between them were solved by a third reviewer. The 04 research were publicized in the 1995 to 2015 period. Altogheter, were searched 975 intravenous devices, keeping them with one of the studied solutions in 420 patients. Th estudies tried the heparin in dosages that vary from 10UI/mL to 100UI/mL versus the saline solution and investigated the complications related to the peripheral venous catheter in a intermittent using. One of these complications was the catheter obstruction, wich were designated as lack or the decrease of the patency of the venous catheter, that can be avoided with an appropriate flushing process. The interventions were tried in different populations, and they were not concordant in their conclusions. Two research recommended the heparin, one, the saline solution, and one of them recommend to use both. The four research affirm that the heparin and the saline solution are safety and effective for the maintenance of the patency of the peripheral venous catheter. However, the authors say point out that the quantity of the simple is not enough to to generalize the results regarding to all hospitalized patients. Thus, this systematic review suggest the necessity of new randomized clinical testings. In addition, the health institutions must promote clinical research in order to validate a solid nursing assistance based on safety and appropriated practices
2

Solução salina versus solução de heparina na perviedade do cateter venoso periférico na terapia venosa intermitente: revisão sistemática / Saline solution versus heparin in the patency of the venous peripheral catheter in the intermittent venous therapy: a systematic review

Adriana Aparecida Constantini Ferrari 10 February 2017 (has links)
O uso do cateter venoso periférico intermitente em pacientes hospitalizados pode lhes trazer grandes benefícios, proporcionando maior liberdade com a higiene pessoal, alimentação, deambulação, além melhorias para a equipe de enfermagem com redução das rotinas diárias. No entanto, obstrução do cateter é algo que vem na contramão de uma assistência adequada, causando desconforto para o paciente e aumento do trabalho de enfermagem. Para evitar tal evento e garantir a perviedade do cateter intravascular, deve-se realizar o flushing com solução salina ou solução de heparina, após a administração de medicamentos ou em horários programados de acordo com o protocolo interno das instituições de saúde. Nesse contexto, surge o questionamento de qual é a melhor solução para manter a perviedade do cateter venoso periférico intermitente. Este estudo trata-se de uma revisão sistemática da literatura, com o objetivo de avaliar a efetividade do uso da solução salina comparada à solução de heparina na manutenção da perviedade dos cateteres venosos periféricos. Foi realizada a busca nas bases de dados eletrônicas Cinahl, Cochrane Central, Embase, Lilacs, Pubmed e Web of Science. Das 372 referências identificadas, 12 estudos foram selecionados após a análise de título e resumo para serem lidos na íntegra, sendo que 04 constituíram a amostra final. A extração e análise dos dados foram realizadas por dois revisores independentes e as divergências entre eles foram solucionadas por um terceiro revisor. Os 04 estudos foram publicados no período de 1995 a 2015. Ao todo, foram investigados 975 dispositivos endovenosos mantidos com uma das soluções estudadas em 420 participantes. Os estudos testaram a solução de heparina em dosagens que variaram de 10UI/mL a 100UI/mL versus a solução salina e investigaram as complicações relacionadas ao cateter venoso periférico em uso intermitente, sendo uma delas a obstrução do cateter a qual denominamos como ausência e/ou diminuição da perviedade do cateter venoso, que pode ser evitada com o flushing de forma adequada. As intervenções foram testadas em diferentes populações e não foram concordantes em suas conclusões; dois estudos recomendaram a solução de heparina, um estudo, a solução salina, e um recomenda o uso das duas soluções. Os quatro estudos discutem que as duas soluções são seguras e eficazes para a manutenção da perviedade do cateter venoso periférico. Porém, os autores afirmam que o tamanho da amostra não é suficiente para generalizar os resultados para todos os pacientes hospitalizados. Assim, essa revisão sistemática sugere a necessidade de que novos ensaios clínicos randomizados sejam realizados e que as instituições de saúde devem fomentar as investigações clínicas para validar uma assistência de enfermagem alicerçada em práticas seguras e de qualidade / The using of intermittent peripheral venous catheter in a hospitalized patient can bring to them important benefits, providing more freedom concerning to the personal hygiene, feeding, ambulation, and a lot of another improvements for the nursing team, reducing the daily routines. However, catheter obstruction it is something that disturb an appropriate assistence, provoking discomfort to the patient and increasing the need of job of the nursing team. To avoid this fact and to ensure the patency of the intervascular catheter, must to do the flushing process with saline solution or hepamin, after the application of drugs or in pre established time according to the protocol of procedure of the health institutions. In this regard, it emerges the questioning about what is the best solution to keep the patency of the intermittent peripheral venous catheter. This research is a systematic review about the litetature on this subject, and it aims to evaluate the effectiveness of the using of the saline solution in comparison to the heparin in the maintenance of the patency of the peripheral venous catheter. It has been done a research in the electronic databases Cinahl, Cochrane Central, Embase, Lilacs, Pubmed and Web of Science. An amount of 372 references was identified, but just 12 research were selected after the analysis of their titles and abstracts to be fully read. In the end, 04 of them were picked as definitive samples.The data collect and the anlysis were done by two independent reviewers, and the divergences between them were solved by a third reviewer. The 04 research were publicized in the 1995 to 2015 period. Altogheter, were searched 975 intravenous devices, keeping them with one of the studied solutions in 420 patients. Th estudies tried the heparin in dosages that vary from 10UI/mL to 100UI/mL versus the saline solution and investigated the complications related to the peripheral venous catheter in a intermittent using. One of these complications was the catheter obstruction, wich were designated as lack or the decrease of the patency of the venous catheter, that can be avoided with an appropriate flushing process. The interventions were tried in different populations, and they were not concordant in their conclusions. Two research recommended the heparin, one, the saline solution, and one of them recommend to use both. The four research affirm that the heparin and the saline solution are safety and effective for the maintenance of the patency of the peripheral venous catheter. However, the authors say point out that the quantity of the simple is not enough to to generalize the results regarding to all hospitalized patients. Thus, this systematic review suggest the necessity of new randomized clinical testings. In addition, the health institutions must promote clinical research in order to validate a solid nursing assistance based on safety and appropriated practices
3

Estudo experimental comparativo de remendos arteriais de polidimetilsiloxano com reforço de tecido de poliéster (PDMSr) versus politetrafluoretileno expandido (PTFEe) em aorta de coelhos / Patch of polydimethylsiloxane reinforced with polyester fabric for aortic angioplasty in rabbits

Sassaki Neto, Paulo Isao 15 October 2014 (has links)
Introdução: Apesar de bons resultados descritos na literatura, o substituto ideal para a utilização como remendo no fechamento arterial ainda não existe. Por este motivo, ainda há espaço para a busca por remendo que seja biocompatível, e que apresente facilidade de manuseio e resultados satisfatórios. Avaliamos remendos arteriais de silicone (polidimetilsiloxano com reforço em poliéster - PDMSr) em comparação com remendos arteriais de PTFEe. Objetivo: O objetivo deste trabalho é comparar, em modelo experimental, em coelhos, os resultados de remendos arteriais feitos em PDMSr com remendos de PTFEe. Materiais e Método: A amostra foi definida em 10 animais que completassem todas as etapas da pesquisa em cada grupo. Os animais foram submetidos à laparotomia mediana e abertura longitudinal da aorta de aproximadamente 8mm, realizando-se o seu fechamento com remendo do grupo selecionado, seguido do fechamento por planos. Os animais foram mantidos em biotério até o 60º PO, quando, então, realizou-se arteriografia de controle, e análise macro e microscópica de peça. Resultados: Para se atingir a amostra desejada, foram necessários 12 procedimentos no grupo PDMSr e 16 no grupo PTFEe. Ocorreram 2 óbitos no grupo PDMSr e 6 no grupo PTFEe. Apesar do número maior de óbitos no grupo PTFEe não houve diferença estatística na sobrevida entre os grupos. Um animal do grupo PDMSr apresentou monoparesia em pata posterior direita e um animal do grupo PTFEe apresentou hérnia incisional. Não houve diferença estatística nas complicações entre os grupos. O tempo operatório foi estatisticamente maior no grupo PTFEe quando comparamos todos os animais, fato que não se repetiu quando excluímos os animais que faleceram. O peso e o tempo operatório foram estatisticamente maiores nos animais que morreram. Todos os animais que chegaram ao final do tempo de estudo apresentavam aorta patente. Na análise macroscópica da peça, houve, estatisticamente, maior reação tecidual periprótese no grupo PTFEe. A microscopia eletrônica de varredura evidenciou cobertura de todo o remendo de PDMSr por tecido similar ao endotélio, enquanto, nos remendos de PTFEe, o crescimento limitou-se às bordas da linha de sutura e ilhas isoladas no seu centro. Conclusão: O material estudado apresentou resultados comparáveis ao do PTFEe, porém com menor reação tecidual local e maior proliferação celular para a luz do vaso. Apesar de novos estudos serem necessários, inclusive para avaliação de uso em humanos, o presente estudo apresenta resultados promissores que encorajam a continuidade de sua pesquisa / Introduction: Although good results are reported for various materials for use as patches for arterial closure, as yet none of these is ideal. Therefore, research is continuing into development of a patch that is biocompatible and provides ease of handling, while having satisfactory outcomes. A new silicone arterial patch (polydimethylsiloxane reinforced with polyester fabric, PDMSr) was compared with patches made of expanded polytetrafluoroethylene (ePTFE). Objective: To compare the outcomes between arterial patches made of PDMSr with those made of ePTFE, in an experimental rabbit model. Materials and Method: Rabbits were placed in two groups, and received either PDMSr or ePTFE arterial patches (PDMSr group and ePTFE group, respectively). The animals underwent laparotomy and longitudinal opening of the aorta, which was then closed with the selected patch, followed by suture of all layers. The animals were kept in their cages until the 60th postoperative day, when arteriography, removal of the aorta, and macroscopic and optic and scanning electron microscopic analyzes of the aorta were performed. Ten rabbits from each group that had completed all stages of the research were included in analyses. Results: Twelve procedures were performed in the PDMSr group and 16 in the ePTFE group. There were 2 deaths in the PDMSr group and 6 in the ePTFE group. Despite the higher number of deaths in the ePTFE group, there was no statistical difference in survival rate between the groups. One animal in the PDMSr group developed monoparesis in its right hind paw and 1 animal in the ePTFE group had an incisional hernia. There was no statistical difference in complications between the groups. The operative time was significantly longer in the ePTFE group when all animals were included in analysis, but not when animals that died were excluded. Body weight was significantly greater and operative time was significantly longer in animals that died. Postsurgical aortic patency in the survival animals was 100% in both groups by arteriography. Macroscopically, tissue reaction around the prosthesis was greater in the ePTFE group (statistically significant). Microscopically, the PDMSr patches were entirely covered with a cellular endothelium-like tissue, while tissue growth on the ePTFE patches was limited to the edges of the suture line and to isolated central islands. Conclusion: The two materials showed comparable outcomes; however, PDMSr showed cellular proliferation to the entire graft, and less local inflammatory reaction compared with ePTFE. Although further studies are required, including assessment in humans, the results of the present study indicate that PDMSr shows promise as an arterial patch material
4

Estudo experimental comparativo de remendos arteriais de polidimetilsiloxano com reforço de tecido de poliéster (PDMSr) versus politetrafluoretileno expandido (PTFEe) em aorta de coelhos / Patch of polydimethylsiloxane reinforced with polyester fabric for aortic angioplasty in rabbits

Paulo Isao Sassaki Neto 15 October 2014 (has links)
Introdução: Apesar de bons resultados descritos na literatura, o substituto ideal para a utilização como remendo no fechamento arterial ainda não existe. Por este motivo, ainda há espaço para a busca por remendo que seja biocompatível, e que apresente facilidade de manuseio e resultados satisfatórios. Avaliamos remendos arteriais de silicone (polidimetilsiloxano com reforço em poliéster - PDMSr) em comparação com remendos arteriais de PTFEe. Objetivo: O objetivo deste trabalho é comparar, em modelo experimental, em coelhos, os resultados de remendos arteriais feitos em PDMSr com remendos de PTFEe. Materiais e Método: A amostra foi definida em 10 animais que completassem todas as etapas da pesquisa em cada grupo. Os animais foram submetidos à laparotomia mediana e abertura longitudinal da aorta de aproximadamente 8mm, realizando-se o seu fechamento com remendo do grupo selecionado, seguido do fechamento por planos. Os animais foram mantidos em biotério até o 60º PO, quando, então, realizou-se arteriografia de controle, e análise macro e microscópica de peça. Resultados: Para se atingir a amostra desejada, foram necessários 12 procedimentos no grupo PDMSr e 16 no grupo PTFEe. Ocorreram 2 óbitos no grupo PDMSr e 6 no grupo PTFEe. Apesar do número maior de óbitos no grupo PTFEe não houve diferença estatística na sobrevida entre os grupos. Um animal do grupo PDMSr apresentou monoparesia em pata posterior direita e um animal do grupo PTFEe apresentou hérnia incisional. Não houve diferença estatística nas complicações entre os grupos. O tempo operatório foi estatisticamente maior no grupo PTFEe quando comparamos todos os animais, fato que não se repetiu quando excluímos os animais que faleceram. O peso e o tempo operatório foram estatisticamente maiores nos animais que morreram. Todos os animais que chegaram ao final do tempo de estudo apresentavam aorta patente. Na análise macroscópica da peça, houve, estatisticamente, maior reação tecidual periprótese no grupo PTFEe. A microscopia eletrônica de varredura evidenciou cobertura de todo o remendo de PDMSr por tecido similar ao endotélio, enquanto, nos remendos de PTFEe, o crescimento limitou-se às bordas da linha de sutura e ilhas isoladas no seu centro. Conclusão: O material estudado apresentou resultados comparáveis ao do PTFEe, porém com menor reação tecidual local e maior proliferação celular para a luz do vaso. Apesar de novos estudos serem necessários, inclusive para avaliação de uso em humanos, o presente estudo apresenta resultados promissores que encorajam a continuidade de sua pesquisa / Introduction: Although good results are reported for various materials for use as patches for arterial closure, as yet none of these is ideal. Therefore, research is continuing into development of a patch that is biocompatible and provides ease of handling, while having satisfactory outcomes. A new silicone arterial patch (polydimethylsiloxane reinforced with polyester fabric, PDMSr) was compared with patches made of expanded polytetrafluoroethylene (ePTFE). Objective: To compare the outcomes between arterial patches made of PDMSr with those made of ePTFE, in an experimental rabbit model. Materials and Method: Rabbits were placed in two groups, and received either PDMSr or ePTFE arterial patches (PDMSr group and ePTFE group, respectively). The animals underwent laparotomy and longitudinal opening of the aorta, which was then closed with the selected patch, followed by suture of all layers. The animals were kept in their cages until the 60th postoperative day, when arteriography, removal of the aorta, and macroscopic and optic and scanning electron microscopic analyzes of the aorta were performed. Ten rabbits from each group that had completed all stages of the research were included in analyses. Results: Twelve procedures were performed in the PDMSr group and 16 in the ePTFE group. There were 2 deaths in the PDMSr group and 6 in the ePTFE group. Despite the higher number of deaths in the ePTFE group, there was no statistical difference in survival rate between the groups. One animal in the PDMSr group developed monoparesis in its right hind paw and 1 animal in the ePTFE group had an incisional hernia. There was no statistical difference in complications between the groups. The operative time was significantly longer in the ePTFE group when all animals were included in analysis, but not when animals that died were excluded. Body weight was significantly greater and operative time was significantly longer in animals that died. Postsurgical aortic patency in the survival animals was 100% in both groups by arteriography. Macroscopically, tissue reaction around the prosthesis was greater in the ePTFE group (statistically significant). Microscopically, the PDMSr patches were entirely covered with a cellular endothelium-like tissue, while tissue growth on the ePTFE patches was limited to the edges of the suture line and to isolated central islands. Conclusion: The two materials showed comparable outcomes; however, PDMSr showed cellular proliferation to the entire graft, and less local inflammatory reaction compared with ePTFE. Although further studies are required, including assessment in humans, the results of the present study indicate that PDMSr shows promise as an arterial patch material

Page generated in 0.0843 seconds