• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 87
  • 1
  • Tagged with
  • 89
  • 89
  • 89
  • 89
  • 56
  • 56
  • 54
  • 31
  • 22
  • 16
  • 16
  • 14
  • 14
  • 12
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Investigação das condições de crescimento e produção de metabólitos secundários das linhagens de fungos Penicillium citrinum e Penicillium oxalicum / Investigation of conditions for growth and production of secondary metabolites of fungi strains P. citrinum and P. oxalicum

Eli Fernando Pimenta 01 October 2010 (has links)
No presente estudo, duas espécies de fungos isoladas do ambiente marinho tiveram seus extratos brutos ativos contra Staphylococcus aureus e Candida albicans para uma espécie de P. citrinum e, atividade citotóxica e contra Mycobacterium tuberculosis para uma espécie de P. oxalicum. Estas foram estudadas com a finalidade de otimizar suas condições de crescimento para produção de metabólitos secundários. Foram realizadas análises multivariadas utilizando planejamento fatorial fracionário. Foram obtidas duas condições ótimas de crescimento para as duas linhagens de Penicillium. O crescimento em maior volume em condições de cultura otimizadas para P. oxalicum permitiu observar a presença de três metabólitos secundários no extrato do meio de cultura. Dois puderam ser isolados e identificados: a meleagrina 52 e a oxalina 26. A metodologia utilizada para se obter uma maior quantidade de metabólitos secundários proporcionou, ainda, o incremento em cerca de 150% na área do pico da oxalina. A partir do crescimento em maior volume em condições de cultura otimizadas para P. citrinum foi possível observar presença de pelo menos onze diferentes metabólitos na análise dos extratos obtidos do meio de cultura. Foi possível identificar e isolar quatro compostos já conhecidos: a (8E)-1-(2,3-diidropirrol-1-il)-2-metildec-8-eno-1,3-diona 56; a 1-(2,3-diidropirrol-1-il)-2-metildecano-1,3-diona 58; a 2-((E)-hept-5-enil)-6,7,8,8a-tetraidro-3-metilpirrolo[2,1-b][1,3]oxazin-4-ona 59 e a citrinina 31. Também foram isolados dois novos alcalóides indólicos contendo um grupo nitro na molécula que foram nomeadas de citrinalinas A 60 e B 62. Foi realizado, também, um estudo com P. citrinum visando a maior produção das citrinalinas, que possibilitou o incremento na produção da citrinalina B. / In this study, two species of fungi isolated from the marine environment had their active extracts against Staphylococcus aureus and Candida albicans to a strain of P. citrinum, and activity cytotoxic and against Mycobacterium tuberculosis to a strain of P. oxalicum. This studied aims the optimization their growth conditions for the production of secondary metabolites. Multivariate analysis using a fractional factorial design were used to establish optimal growth conditions for both Penicillium strains. Two optimal growth conditions were obtained for both Penicillium strains. A largest growth volume of P. oxalicum using optimized conditions enabled the detection of three secondary metabolites in the culture media crude extract. Two of such compounds were isolated and identified: meleagrin 52 and oxaline 26. The methodology used to increase the production of secondary metabolites by P. citrinum enabled an increase of 150% in the peak area of oxaline. A largest growth volume of P. citrinum led to the detection of eleven different metabolites in the culture media. Four of these compounds were isolated and identified as the known (8E)-1-(2,3-dihydropyrrol-1-yl)-2-methyldec-8-ene-1,3-dione 56; the 1-(2,3-dihydropyrrol-1-yl)-2-methyldecane-1,3-dione 58; the 2-((E)-hept-5-enyl)-6,7,8,8a-tetrahydro-3-methylpyrrolo[2,1-b][1,3]oxazin-4-one 59 and citrinin 31. Two new indole alkaloids containing a nitro group were also isolated and identified, named citrinalins A 60 and B 62. A further study with P. citrinum aiming an enhanced production of citrinalins allowed a significant increase in the production of citrinalin B.
62

Síntese de polímeros de impressão molecular e sua aplicação na técnica de extração em fase sólida

Peçanha, Bruna Rachel de Britto 23 March 2017 (has links)
Submitted by Biblioteca da Faculdade de Farmácia (bff@ndc.uff.br) on 2017-03-23T19:00:13Z No. of bitstreams: 1 Peçanha, Bruna Rachel de Britto [Dissertação, 2012].pdf: 3907379 bytes, checksum: f2acabc3c1c39363b86f0d651d6b5936 (MD5) / Made available in DSpace on 2017-03-23T19:00:13Z (GMT). No. of bitstreams: 1 Peçanha, Bruna Rachel de Britto [Dissertação, 2012].pdf: 3907379 bytes, checksum: f2acabc3c1c39363b86f0d651d6b5936 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Polímeros de impressão molecular (MIPs) foram sintetizados e aplicados como adsorventes na técnica de extração em fase sólida (EFS). O método de polimerização por precipitação foi utilizado para a síntese dos polímeros, devido à simplicidade de preparo, altos rendimentos e obtenção de partículas mais uniformes, devido a não trituração do polímero. O MIP foi sintetizado com ácido metacrílico (MAA) como monômero funcional, trimetacrilato de trimetilolpropano (TRIM) e dimetacrilato de etilenoglicol (EDMA) como agentes de reticulação e o cloridrato de amilorida (AMI) foi escolhido como molécula-molde. Diferentes proporções de MAA, TRIM, EDMA, volume e tipo de solvente foram utilizadas para ajuste das condições ideais de síntese. Os MIP foram avaliados quanto à capacidade de adsorção comparando-se a polímeros sintetizados na ausência da molécula-molde (NIP, polímeros não impressos). O solvente de elevada polaridade empregado na síntese (THF:MeOH:H2O) permitiu o emprego da técnica para moléculas polares como AMI. O controle no volume de solvente permitiu a obtenção de partículas maiores, de modo que a EFS foi realizada em condições usuais, o que confere um potencial para aplicação dessa técnica de polimerização na preparação de adsorventes para EFS. O polímero que apresentou maior capacidade adsortiva no ensaio realizado em tampão citrato-acetato pH 6,5 foi o MIP/NIP 12 (AMI:MAA:TRIM 1:8:10), com uma taxa média de adsorção de 83 e 88% para NIP e MIP, respectivamente. A adsorção foi elevada devido a interação iônica entre MAA e AMI promovida pelo controle de pH, porém foi não específica. O polímero MIP/NIP 12 foi aplicado como adsorvente na EFS, onde a recuperação de AMI foi avaliada nos resíduos de carregamento e eluição com solventes. O carregamento com tampão citrato-acetato pH 6,5 foi o ideal, favorecendo a interação iônica do polímero com o analito. A eluição total de AMI do cartucho somente ocorre após lavagem com o solvente na presença de ácido, que protona os grupos carboxila do polímero, rompendo assim a interação iônica com o analito / Molecularly imprinted polymers (MIPs) were synthesized and applied as adsorbents in solid-phase extraction technique (SPE). The polymers have been synthesized by precipitation polymerization method because of its simplicity, high yields and good control of final size and shape of particles. MIP was synthesized using methacrylic acid (MAA) as functional monomer, trimethylolpropane trimethacrylate (TRIM) and ethyleneglycol dimethacrylate (EDMA) as cross-linker and amiloride hydrochloride (AMI) was chosen as template. Different ratios of MAA, TRIM and EDMA, volume and type of solvent were used to adjust the optimal synthesis conditions. The MIP were tested for adsorption capacity compared to the polymers synthesized in the absence of template molecule (NIP, non-imprinted polymers). The polar solvent mixture used (THF:MeOH:H2O) allowed the synthesis of MIP of polar molecules as AMI. The solvent volume control afforded the larger particles so the SPE was performed in the usual conditions, giving a potential application for this polymerization technique in the preparation of adsorbents for SPE. The polymers with higher adsorption capacity at the test performed in citrateacetate buffer pH 6,5 was MIP/NIP 12 (AMI:MAA:TRIM 1:8:10) with adsorption rate of 83 and 88% for NIP and MIP, respectively. The recognition of MIP was due to ionic interaction between MAA and AMI promoted by pH control, but was not specific. The polymer MIP/NIP 12 was used as a solid-phase extraction sorbent and the recoveries of AMI was evaluated using different loading and elution conditions. The loading with buffer citrate-acetate pH 6,5 was optimal, due to ionic interaction of the polymer with the analyte. Total elution of AMI bound to the polymers only occurs after washing with a acid-containing solvent, because of protonation of the carboxyl groups of the polymer and disrupting the ionic interaction with the analyte
63

Desenvolvimento de métodos de extração e determinação de bifenilas policloradas por cromatografia gasosa e detector de captura de elétrons em óleo Ascarel, reator anaeróbio e solo / Development and validation of a method for determination of Polychlorinated Biphenyls (PCBs) of a standard solution PCB Congener MIX 1 by gas chromatography and electron capture detector in three different matrices: Askarel oil, samples from batch anaerobic reactors and soil

Adorno, Maria Angela Tallarico 23 August 2013 (has links)
Bifenilas policloradas (PCBs) são componentes de óleo ascarel, usado extensamente (no Brasil até os anos 80) como isolante em transformadores de energia devido às suas propriedades físico-químicas como estabilidade térmica e alta constante dielétrica. Apesar de ter sido proibido em todo o mundo devido à alta toxicidade dos PCBs presentes em sua composição, ainda resta grande quantidade de ascarel em circulação como resíduo \"passivo\" e resultante de contaminação em trocas dos fluidos dos transformadores, além de vazamentos. A principal forma de eliminação é por incineração, que, além de ser um processo caro, pode provocar a formação de compostos mais tóxicos, as dioxinas. Por isso é importante o monitoramento da concentração dessas substâncias, a fim de evitar maiores impactos ambientais na sua disposição, bem como em estudos de biodegradação. Esta matriz é extremamente complexa, o que torna a extração e determinação desses analitos um processo trabalhoso e difícil. Neste trabalho avaliaram-se métodos de extração e determinação de PCBs presentes na solução padrão comercial PCB Congener MIX 1, SUPELCO (PCBs 10, 28, 52, 138, 153 e 180). O desenvolvimento de métodos de extração (cromatografia em coluna, extração líquido-líquido (L-L), extração em fase sólida (SPE) e micro-extração em fase sólida - SPME) dos PCBs foi seguido da determinação, por cromatografia gasosa com detector por captura de elétrons (CG/DCE), em três matrizes diferentes: óleo ascarel, amostras provenientes de reatores anaeróbios em batelada e solo. Os métodos cuja purificação e extração diminuíram o efeito dos interferentes da matriz, como SPE - Sulfoxide, cromatografia em coluna de sílica e extração L-L com n-hexano foram validados pela avaliação dos seguintes parâmetros: linearidade e faixa de aplicação; precisão instrumental; limite de detecção, limite de quantificação e recuperação absoluta. O critério de escolha entre os métodos para extração dos PCBs do óleo que forneceram maior eficiência (cartucho SPE Sulfoxide e coluna de sílica gel, após lavagem ácida; método da adição de padrão, entre 1,0 e 4,0 mg L-1) deve considerar a disponibilidade de recursos, pois a sílica gel é mais viável economicamente do que o cartucho SPE. Os valores de R2 > 0,99 para o método de extração com sílica, mesmo tendo sido considerados apenas três pontos para a curva de calibração, atestam maior linearidade do que o método com SPE Sulfoxide (R2 entre 0,97 e 0,99). A extração L-L e determinação por CG/DCE dos PCBs (padronização interna) de amostras provenientes de reatores anaeróbios em batelada (aquosas, em matriz extremamente complexa com biomassa e espuma de poliuretano para imobilização de microrganismos) foram eficientes na faixa de concentração entre 0,05 e 0,5 mg L-1. Esse método foi adequado para monitorar PCBs em estudo de degradação anaeróbia e teste de adsorção dos PCBs em espuma; forneceu linearidade com R2 entre 0,93 e 0,96 e limites de detecção de 0,048 a 0,298 mg L-1, além de recuperação absoluta entre 14,1% e 110,7%. As condições testadas por SPME não permitiram a extração dos PCBs de óleo e de solo, principalmente devido à dessorção incompleta dos PCBs da fibra de polidimetil-siloxano, de 100 μm. / Polychlorinated biphenyls (PCBs) are components of ascarel, oil widely used as insulation (until the \'80s in Brazil) due to its physicochemical properties such as thermal stability and high dielectric constant. Despite having been banned worldwide due to the high toxicity of PCBs present in its composition, there are still lots of outstanding ascarel as \"passive\" residue and resulting contamination of fluids in transformers exchanges, plus leaks. The main form of disposal is incineration, which, besides being costly, can cause the formation of more toxic compounds, that is, dioxins. It is therefore important to monitor the concentration of these substances in order to prevent further environmental impacts in their disposal, as well as in studies of biodegradation. This is an extremely complex matrix, which makes the extraction and determination of this analytes very difficult and labor intensive. In this work we have evaluated methods of extraction and determination of the PCBs present in the standard solution Congener MIX 1, SUPELCO (PCBs 10, 28, 52, 138, 153 e 180). The extraction and cleanup developed methods which reduced the effects of interfering matrix as solid phase extraction (SPE) - Sulfoxide, column chromatography on silica and liquid-liquid (L-L) extraction with n-hexane, and solid phase microextraction (SPME) after determination of the PCBs by gas chromatography with electron capture detector (GC/ECD) were validated by assessing the following parameters: linearity and range of application; instrumental precision; detection limit; limit of quantification and absolute recovery. The criterion for choosing between the methods for extraction of PCBs from the oil with a higher efficiency (SPE cartridge Sulfoxide and silica gel column, after acid washing; using the standard addition method, between 1.0 and 4.0 mg L-1) must evaluate the availability resources, since the silica gel is more economically viable than the SPE cartridge. The R2 values > 0.99 for silica extraction method, even though it was considered only three points for the calibration curve, attested higher linearity than the method with SPE Sulfoxide (R2 between 0.97 and 0.99). The L-L extraction and determination by GC/ECD of the PCBs (internal standardization) of samples from batch anaerobic reactors (aqueous, in a very complex matrix with biomass and polyurethane foam for the immobilization of microorganisms) were efficient in the concentration range between 0.05 and 0.5 mg L-1. This method was suitable to monitor PCBs in anaerobic degradation studies and its adsorption on foam; provided R2 linearity between 0.93 and 0.96 and detection limits from 0.048 to 0.298 mg L-1, as well as absolute recovery between 14.1% and 110.7%. The conditions tested for SPME technique did not allow the extraction of the PCBs from the oil and soil, mainly due to the \"incomplete dessorption\" of PCBs from the polydimethylsiloxane fiber of 100 micron.
64

Novas abordagens para exploração de reações químicas relativamente lentas em sistemas de análises em fluxo. Aplicações a amostras de relevância agronômica e ambiental / Novel approaches for exploiting relatively slow chemical reactions in flow analysis systems. Applications to relevant agronomic and environmental samples

Vida, Ana Clara Felix 27 November 2015 (has links)
Diferentes estratégias foram projetadas e desenvolvidas para sistemas de análises em fluxo envolvendo reações químicas relativamente lentas. O aprisionamento da zona da amostra na bobina de reação permite melhorias de sensibilidade em métodos espectrofotométricos em fluxo envolvendo reações catalíticas. Uma característica inerente a esta estratégia é que, de acordo com as baixas concentrações do analito de interesse esperadas nas amostras, pode-se explorar tanto a variação do tempo quanto da temperatura de aquecimento para o desenvolvimento reacional. Esta estratégia evita a geração de bolhas de ar quando temperaturas elevadas são empregadas. O aprisionamento da zona da amostra na bobina de reação em sistema de análises por injeção em fluxo foi aplicado à reação de oxidação do reagente Tiron por peróxido de hidrogênio catalisada por Co(II) para determinação espectrofotométrica de cobalto em gramíneas. O sistema apresentou boas figuras de mérito, tais como repetibilidade [d.p.r. = 0,8% para 0,6 ?g L-1 Co(II), (n = 5)], limite de detecção [0,046 ?g L-1 Co(II)], frequência de amostragem (19 h-1) e consumo de reagente (330 ?g de Tiron por determinação). Os dados de recuperação nas amostras de gramíneas digeridas variaram entre 97% e 113%. O aquecimento explorando o aprisionamento da zona da amostra na cubeta de detecção mostrou-se promissor para implementação de reações relativamente lentas sem a geração de bolhas de ar, e não houve liberação de bolhas mesmo sob a temperatura de 95ºC. Esta estratégia foi aplicada à determinação espectrofotométrica de vanádio em águas minerais envolvendo a oxidação de p-anisidina por bromato catalisada por V(V) e ativada por Tiron. Sob temperatura de 95ºC, boas figuras de mérito foram obtidas, tais como limite de detecção (0,1 ?g L-1), repetibilidade [d.p.r. = 2,1 % para 5,0 ?g L-1 (n = 10)], frequência analítica [25 h-1] e consumo de reagente (3,0 mg de p-anisidina por determinação). Adicionalmente, foi desenvolvido um procedimento analítico em fluxo para monitoramento dos resíduos de ametrina e atrazina potencialmente lixiviáveis em solos, envolvendo também um processo relativamente lento. Um sistema de análises por injeção sequencial foi utilizado para as etapas de dessorção dos herbicidas com solução 0,01 mol L-1 CaCl2 e concentração em fase sólida em linha, seguida da eluição dessas espécies para a separação em uma coluna monolítica C18 conectada a um cromatógrafo líquido por meio de uma válvula de seis vias. Os eluatos eram injetados no cromatógrafo por meio de uma alça de amostragem de 300 ?L conectada à válvula. Boas figuras de mérito foram obtidas, tais como fatores de enriquecimento de 10,2 e 18,8 e limites de detecção de 0,016 e 0,015 mg L-1 para ametrina e atrazina, respectivamente, limite de quantificação de 0,05 mg L-1 para ambos os herbicidas e repetibilidade estimada como 6,3% e 5,1% para 0,05 mg L-1 (n = 10) para ametrina e atrazina, respecivamente. Os dados de adição e recuperação dos herbicidas nos extratos de solos em condições de equilíbrio se situaram na faixa de 85 a 99% / Different approaches to analytical flow systems involving relatively slow chemical reactions were developed. Zone trapping inside the reaction coil enables sensitivity improvements in flow-based spectrophotometric procedures relying on catalytic reactions. The reaction time and/or temperature can be increased for the determination of analytes present in the samples at low concentrations. Exploitation of the strategy avoids the liberation of air bubbles in the analytical path when high temperatures are involved. A flow injection system with zone trapping in the main reactor was developed for the spectrophotometric determination of cobalt in grass samples exploiting the oxidation of Tiron by bromate catalised by Co(II). Good figures of merit such as repeatability [r.s.d. = 0.8% for 0.6 ?g L-1 Co(II), (n = 5)], detection limit [0.046 ?g L-1 Co(II)], sampling frequency [19 h-1] and reagent consumption (330 ?g of Tiron for determination) were attained. Recovery data in grass sample digests varied within 97% e 113%. Zone trapping inside the flow-through cuvette for exploiting high temperatures was also promising for relatively slow reactions, as no liberation of air bubbles was noted even for temperatures as high as 95oC. The approach was applied to the spectrophotometric determination of vanadium in mineral water samples relying on the oxidation of p-anisidine by bromate catalised by V(V) at 95ºC. Good analytical figures of merit such as repeatability [r.s.d. = 2.1% for 5.0 µg L-1 V(V), n = 10], detection limit [0.1 µg L-1 V(V), sample frequency (25 h-1) and reagent consumption (3.0 mg of p-anisidine per determination) were attained. Additionally, an analytical procedure to monitor the potentially leachable ametryn and atrazine residues in soil samples was proposed. As leaching is relatively slow, a sequential injection system was used to perform the herbicide extractions with 0.01 mol L-1 CaCl2 and in-line solid phase extraction followed by elution towards a C18 monolithic column connected to a liquid chomatograph. To this end, the outlet of the column was connected to a 300-µL six-port valve. Regarding analytical performance, enrichment factors and detection limits were 10.2 and 18.8 and 0.016 e 0.015 mg L-1 for ametryn and atrazine, respectively, quantification limits were 0.05 mg L-1 for both herbicides and good repeatability (r.s.d. = 6.3 and 5.1 % for 0.05 mg L-1 of ametryn and atrazine, n = 10) were attained. Recovery data in the soil extracts under equilibrium conditions were within 85 and 99%
65

Desenvolvimento de métodos de extração e determinação de bifenilas policloradas por cromatografia gasosa e detector de captura de elétrons em óleo Ascarel, reator anaeróbio e solo / Development and validation of a method for determination of Polychlorinated Biphenyls (PCBs) of a standard solution PCB Congener MIX 1 by gas chromatography and electron capture detector in three different matrices: Askarel oil, samples from batch anaerobic reactors and soil

Maria Angela Tallarico Adorno 23 August 2013 (has links)
Bifenilas policloradas (PCBs) são componentes de óleo ascarel, usado extensamente (no Brasil até os anos 80) como isolante em transformadores de energia devido às suas propriedades físico-químicas como estabilidade térmica e alta constante dielétrica. Apesar de ter sido proibido em todo o mundo devido à alta toxicidade dos PCBs presentes em sua composição, ainda resta grande quantidade de ascarel em circulação como resíduo \"passivo\" e resultante de contaminação em trocas dos fluidos dos transformadores, além de vazamentos. A principal forma de eliminação é por incineração, que, além de ser um processo caro, pode provocar a formação de compostos mais tóxicos, as dioxinas. Por isso é importante o monitoramento da concentração dessas substâncias, a fim de evitar maiores impactos ambientais na sua disposição, bem como em estudos de biodegradação. Esta matriz é extremamente complexa, o que torna a extração e determinação desses analitos um processo trabalhoso e difícil. Neste trabalho avaliaram-se métodos de extração e determinação de PCBs presentes na solução padrão comercial PCB Congener MIX 1, SUPELCO (PCBs 10, 28, 52, 138, 153 e 180). O desenvolvimento de métodos de extração (cromatografia em coluna, extração líquido-líquido (L-L), extração em fase sólida (SPE) e micro-extração em fase sólida - SPME) dos PCBs foi seguido da determinação, por cromatografia gasosa com detector por captura de elétrons (CG/DCE), em três matrizes diferentes: óleo ascarel, amostras provenientes de reatores anaeróbios em batelada e solo. Os métodos cuja purificação e extração diminuíram o efeito dos interferentes da matriz, como SPE - Sulfoxide, cromatografia em coluna de sílica e extração L-L com n-hexano foram validados pela avaliação dos seguintes parâmetros: linearidade e faixa de aplicação; precisão instrumental; limite de detecção, limite de quantificação e recuperação absoluta. O critério de escolha entre os métodos para extração dos PCBs do óleo que forneceram maior eficiência (cartucho SPE Sulfoxide e coluna de sílica gel, após lavagem ácida; método da adição de padrão, entre 1,0 e 4,0 mg L-1) deve considerar a disponibilidade de recursos, pois a sílica gel é mais viável economicamente do que o cartucho SPE. Os valores de R2 > 0,99 para o método de extração com sílica, mesmo tendo sido considerados apenas três pontos para a curva de calibração, atestam maior linearidade do que o método com SPE Sulfoxide (R2 entre 0,97 e 0,99). A extração L-L e determinação por CG/DCE dos PCBs (padronização interna) de amostras provenientes de reatores anaeróbios em batelada (aquosas, em matriz extremamente complexa com biomassa e espuma de poliuretano para imobilização de microrganismos) foram eficientes na faixa de concentração entre 0,05 e 0,5 mg L-1. Esse método foi adequado para monitorar PCBs em estudo de degradação anaeróbia e teste de adsorção dos PCBs em espuma; forneceu linearidade com R2 entre 0,93 e 0,96 e limites de detecção de 0,048 a 0,298 mg L-1, além de recuperação absoluta entre 14,1% e 110,7%. As condições testadas por SPME não permitiram a extração dos PCBs de óleo e de solo, principalmente devido à dessorção incompleta dos PCBs da fibra de polidimetil-siloxano, de 100 μm. / Polychlorinated biphenyls (PCBs) are components of ascarel, oil widely used as insulation (until the \'80s in Brazil) due to its physicochemical properties such as thermal stability and high dielectric constant. Despite having been banned worldwide due to the high toxicity of PCBs present in its composition, there are still lots of outstanding ascarel as \"passive\" residue and resulting contamination of fluids in transformers exchanges, plus leaks. The main form of disposal is incineration, which, besides being costly, can cause the formation of more toxic compounds, that is, dioxins. It is therefore important to monitor the concentration of these substances in order to prevent further environmental impacts in their disposal, as well as in studies of biodegradation. This is an extremely complex matrix, which makes the extraction and determination of this analytes very difficult and labor intensive. In this work we have evaluated methods of extraction and determination of the PCBs present in the standard solution Congener MIX 1, SUPELCO (PCBs 10, 28, 52, 138, 153 e 180). The extraction and cleanup developed methods which reduced the effects of interfering matrix as solid phase extraction (SPE) - Sulfoxide, column chromatography on silica and liquid-liquid (L-L) extraction with n-hexane, and solid phase microextraction (SPME) after determination of the PCBs by gas chromatography with electron capture detector (GC/ECD) were validated by assessing the following parameters: linearity and range of application; instrumental precision; detection limit; limit of quantification and absolute recovery. The criterion for choosing between the methods for extraction of PCBs from the oil with a higher efficiency (SPE cartridge Sulfoxide and silica gel column, after acid washing; using the standard addition method, between 1.0 and 4.0 mg L-1) must evaluate the availability resources, since the silica gel is more economically viable than the SPE cartridge. The R2 values > 0.99 for silica extraction method, even though it was considered only three points for the calibration curve, attested higher linearity than the method with SPE Sulfoxide (R2 between 0.97 and 0.99). The L-L extraction and determination by GC/ECD of the PCBs (internal standardization) of samples from batch anaerobic reactors (aqueous, in a very complex matrix with biomass and polyurethane foam for the immobilization of microorganisms) were efficient in the concentration range between 0.05 and 0.5 mg L-1. This method was suitable to monitor PCBs in anaerobic degradation studies and its adsorption on foam; provided R2 linearity between 0.93 and 0.96 and detection limits from 0.048 to 0.298 mg L-1, as well as absolute recovery between 14.1% and 110.7%. The conditions tested for SPME technique did not allow the extraction of the PCBs from the oil and soil, mainly due to the \"incomplete dessorption\" of PCBs from the polydimethylsiloxane fiber of 100 micron.
66

Aplicação da cromatografia a gás associada à espectrometria de massas em tandem no diagnóstico da deficiência de 3β-hidroxidesidrogenase / Application of gas chromatography coupled to tandem mass spectrometry in the diagnosis of 3β-hidroxidesidrogenase deficiency

Presutti, Thais Rodrigues 10 April 2017 (has links)
Pregnenolona (PREG) e 17-alfa-hidroxipregnenolona (17OHPREG) são dois esteroides produzidos pela glândula adrenal e precursores de vários hormônios esteroidais. A dosagem desses compostos tem aplicações clínicas, como o diagnóstico de doenças relacionadas aos corticoesteroides e mineralocorticóides e especialmente na avaliação da atividade da enzima 3-β-hidroxidesidrogenase que é decisiva no diagnóstico de um dos tipos de hiperplasia da glândula adrenal que causa defeitos severos na síntese de esteroides. Métodos cromatográficos associados à espectrometria de massas superaram a especificidade reduzida dos imunoensaios e tem sido crescentemente utilizados na quantificação de esteroides. Os últimos anos tem sido marcados pela hegemonia da cromatografia líquida acoplada à espectrometria de massas em tandem (LC-MS/MS) em grande parte devido à velocidade e possibilidade da análise direta de vários analitos. Porém, no caso específico dos esteroides de tipo 3-hidroxi-5-eno, que apresentam baixa afinidade protônica e, portanto, baixa eficiência de ionização, são necessárias muitas etapas para a conversão em derivados mais detectáveis. Embora desfavorecida em relação ao LC-MS/MS nos últimos anos, a cromatografia gasosa acoplada à espectrometria de massas (CG-MS) apresenta várias características favoráveis para a análise de esteroides como a eficiência cromatográfica ainda insuperável. Adicionalmente, a incorporação da espectrometria de massas em tandem ao CG (CG-MS/MS) torna a técnica tão seletiva quanto LC-MS/MS. No presente trabalho, foi desenvolvido um novo método que permite a extração e derivatização simultâneas da PREG e 17OHPREG de amostras de soro tornando o método de preparo da amostra tão simples quanto os descritos para LC-MS/MS. O método de detecção desenvolvido baseado em ionização química no modo negativo obteve a sensibilidade necessária para o diagnóstico da deficiência da enzima 3-beta-hidroxidesidrogenase utilizando apenas 250 &#181:L de amostra. / Pregnenolone (PREG) and 17α-hydroxypregnenolone (17OHPREG) are two steroid precursors produced by the adrenal gland. The quantification of these compounds is essential for the evaluation of 3-β-hidroxidesidrogenase enzyme activity, which promotes the conversion of PREG in 17OHPREG. The 3-&#946:-hidroxidesidrogenase deficiency is a rare but severe type of adrenal hyperplasia that causes serious defects in steroid synthesis. Chromatographic methods coupled to mass spectrometry overcame immunoassays limitations such as reduced specificity, and have been widely used for steroids quantification. Recent years have been marked by liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) hegemony due to the speed and possibility to analyze directly several analytes. However, in the case of type 3-hydroxy-5-ene steroids, which have low affinity for protons and, therefore, low ionization efficiency, many steps are required for conversion to detectable products. Notwithstanding, gas chromatography coupled to mass spectrometry (GC-MS) has some favorable features for steroid analysis such as unbeatable chromatographic efficiency. In addition, the incorporation of tandem mass spectrometry (GC-MS/MS) makes it as selective as LC-MS/MS. In this study, a new method for simultaneous extraction and derivatization of PREG and 17OHPREG from serum was developed. This procedure makes sample preparation for GC-MS/MS as simples as those described for LC-MS/MS. The detection method based on negative mode chemical ionization achieved the sensitivity required for the diagnosis of 3-β-hidroxidesidrogenase defficiency using only 250 µL of sample.
67

Desenvolvimento de procedimento analítico para a determinação de ácido salicílico em materiais vegetais explorando cromatografia por injeção sequencial / Development of an analytical procedure for the determination of salicylic acid in plant materials exploiting sequential injection chromatography

Barrientos, Marcia Otto 24 July 2015 (has links)
A cromatografia por injeção sequencial com extração em fase sólida (EFS) em linha foi explorada para a determinação de ácido salicílico em amostras vegetais. Uma mini coluna de polietileno, preenchida com sílica funcionalizada C18, foi utilizada para EFS, com tampão fosfato pH 5,2 como eluente. O eluato foi diretamente transferido para a separação cromatográfica em uma coluna monolítica C18, utilizando solução de acetonitrila/tampão acetato pH 4,75 (5:95, v/v) como fase móvel. A detecção foi realizada por fluorescência com excitação em 298 nm e emissão em 406 nm. Os sinais analíticos foram baseados na altura do pico cromatográfico referente ao ácido salicílico em um tempo de retenção de 9.0 min. Os limites de detecção (99,7% de confiança) e quantificação foram estimados em 80 e 240 ?g L-1, respectivamente. A precisão foi estimada através do coeficiente de variação intradia (n = 10) em 0,99% e interdia (3 dias) em 3,6%. A resposta foi linear até 8,0 mg L-1 (r = 0,996). A resolução em relação aos demais componentes da matriz, o número de pratos e a altura equivalente a um prato foram estimados em 6,0; 3980 e 12,6 ?m, respectivamente. Utilizando calibração pelo método das adições de padrão, foram estimadas recuperações entre 74,2 e 96,4% em 4 amostras de folhas de soja. Com estes resultados conclui-se que o procedimento é adequado à determinação de ácido salicílico nos materiais vegetais com a remoção de interferentes em linha, tendo as vantagens de ser um procedimento rápido (ca. 17 min por determinação), limpo (consumo de ca. 320 ?L de acetonitrila por determinação), de custo relativamente baixo, suficientemente sensível e seletivo / Sequential injection cromatography with on-line solid phase extraction (SPE) was explored for the determination of salicylic acid in vegetable samples. A polyethylene column filled with C18-bonded silica was used for SPE, with a phosphate buffer pH 5.2 as eluent. The treated extract was directly sent towards chromatographic separation in a C18 monolithic column with an acetonitrile/acetate buffer solution, pH 4,75 (5:95, v/v) as mobile phase before fluorescence detection (excitation at 298 nm and emission at 406 nm). The analytical signals were based on peak height at the 9.0 min retention time. Limits of detection (99.7% confidence level) and quantification were estimated at 80 and 240 ?g L-1. Precision was estimated through intraday coefficient of variation (n = 10) at 0.99% and interday (3 days) at 3.6 %. A linear response up to 8.0 mg L-1 was estimated (r = 0.996). Resolution, number of plates and the height equivalent to one plate were estimated at 6.0, 3980 and 12,6 ?m, respectively. With calibration by the standard additions method recoveries within 74.2 and 96.4 % were estimated to four soy leaves samples. Thus, the procedure is suitable for the determination of salicylic acid in the extracts with on-line removal of interferences, being a rapid (ca. 17 min per determination), clean (ca. 320 ?L of acetonitrile by determination), inexpensive, and suitably sensitive and selective
68

Metodologias para determinação de fármacos, metabólitos e disruptores endócrinos em água de abastecimento público utilizando técnicas de separação em meio líquido (CE/UV, CE-MS, LC-MS/MS) / Methods for determination of pharmaceuticals, their metabolites and endocrine disruptors in surface water using separation techniques in liquid media (CE/UV, CE-MS, HPLC-MS/MS)

Costa, Ana Carolina de Oliveira 03 December 2009 (has links)
Este trabalho apresenta o desenvolvimento e validação de métodos analíticos para investigar a presença de fármacos e seus metabólitos, assim como disruptores endócrinos, em amostras de águas superficiais, utilizando estratégias de \"clean up\" e enriquecimento de amostra no modo \"on line\" (\"stacking\") e \"off line\" (extração em fase sólida, SPE), em junção com técnicas de separação avançadas em meio líquido (eletroforese capilar, CE, e cromatografia a líquido, LC, com detecção UV, e seus acoplamentos com espectrometria de massas). No primeiro Capítulo são discutidos aspectos gerais sobre os produtos farmacêuticos, produtos de higiene pessoal e disruptores endócrinos, bem como a origem e ocorrência destas substâncias no meio ambiente. O segundo Capítulo aborda o desenvolvimento de um método de separação capaz de determinar oito substâncias entre fármacos de caráter ácido e metabólitos (diclofenaco, bezafibrato, fenoprofeno, ibuprofeno, cetoprofeno, naproxeno e ácidos gentísico e salicílico) numa única corrida, utilizando eletroforese capilar com enriquecimento em linha da amostra (stacking do analito baseado em grande volume de injeção da amostra) utilizando eletrólito de corrida constituído por 30 mmol L-1 de tetraborato de sódio e 5 mmol L-1 de Brij 35, pH 9,3. O método proposto alcançou limites de detecção que variaram de 2 µg L-1 para o fármaco naproxeno até 80 µg L-1 para o ibuprofeno. No terceiro capítulo é explorado um método de separação por CE para nove substâncias entre fármacos e hormônios (fluoxetina, trimetoprima, diazepam, carbamazepina, propranolol, clofibrato, fenofibrato, etinilestradiol e estrona). Utilizou-se como estratégia de pré-concentração dos analitos, o modo \"stacking\" de micelas com grande volume de injeção de amostra. Este método chegou a limites de detecção na ordem de 9 µg L-1 com eletrólito de corrida composto por 30 mmol L-1 de ácido fosfórico, 40 mmol L-1 de dodecilsulfato de sódio, 20% (v,v) de acetonitrila e 0,1% (v,v) de trietilamina. No quarto capítulo, foi realizado o estudo de parâmetros físico-químicos que estão relacionados à técnica de extração em fase sólida, tais como tipo do sorvente, volume de capacidade, volume de eluição, lavagem do cartucho de extração, entre outros. As condições ótimas de \"clean up\" e pré-concentração \"off line\" da amostra obtidas foram combinadas com as condições ótimas de pré-concentração \"on line\" e separação descritas nos Capítulos 2 e 3, para todas as substâncias abordadas ali, com o intuito de analisar amostras reais de água superficial coletadas no reservatório Billings (Estado de São Paulo). O método combinado permitiu alcançar concentrações da ordem de 500 ng L-1, com valores de recuperação satisfatórios (58 - 88%), quando levada em consideração a origem complexa da matriz ambiental. No quinto capítulo, desenvolveu-se um método de análise de p-hidroxibenzoatos de alquila, substâncias utilizadas como conservantes em diversos produtos de uso diário, utilizando eletroforese capilar associada a estratégias de concentração \"on line\" (stacking com injeção de grande volume de amostra) e \"off line\" (SPE). O método proposto, utilizando eletrólito constituído por 40 mmol L-1 de glicina e 40 mmol L-1 de trietilamina, foi aplicado na análise destas substâncias em amostras de água superficial, alcançando níveis de concentração da ordem de 4 6 µg L-1. O sexto capítulo aborda o desenvolvimento de um método por eletroforese capilar destinada à análise de alquilbenzeno sulfonato linear (LAS) e homólogos, tensoativo comumente utilizado na composição de detergentes de uso doméstico e industrial. O eletrólito de separação era composto de 60 mmol L-1 TRIS, 30 mmol L-1 HIBA, 15 mmol L-1 Brij 35 e 40% (v,v) acetonitrila. Foi realizada uma etapa de extração em fase sólida (C18), e uma concentração total de LAS na ordem de 1,09 mg L-1 foi encontrada em uma amostra de efluente de estação de tratamento de esgoto. No capítulo 7 foi desenvolvido um método utilizando eletroforese capilar acoplada a um espectrômetro de massas, com analisador \" ion trap\", para a análise dos fármacos cimetidina, propranolol, salbutamol, trimetoprima e metoclopramida. Amostras de água coletadas no reservatório Billings foi fortificada com os fármacos em estudo e submetida a procedimento de extração em fase sólida em cartuchos de poliestireno divinilbenzeno (PS-DVB). O método permitiu a análise das substâncias estudadas na concentração aproximada de 40 µg L-1. Finalmente, no oitavo capítulo foi explorado um método envolvendo cromatografia líquida de alta eficiência, hifenada a dois tipos de espectrômetros de massas: um triplo quadrupolo e um triplo quadrupolo com \"ion trap\" linear. Foram investigados fármacos de diversas classes em amostras de água coletadas no reservatório Billings, sendo possível encontrar carbamazepina na concentração de 20 ng L-1, com apenas uma etapa de filtração da amostra antecedendo a análise, utilizando o triplo quadrupolo. Cabe destacar que o LOD para este analito foi de 400 fg L-1, sem nenhum tratamento da amostra visando préconcentração. / This work presents the development and validation of analytical methods to investigate the presence of pharmaceutical compounds, their metabolites and endocrine disruptors in surface water using on line (stacking) and off line (solid phase extraction) sample clean up and enrichment strategies coupled to advanced separation techniques in liquid medium (capillary electrophoresis and liquid chromatography with UV detection and their hyphenation with mass spectrometry). In the first Chapter, general aspects on pharmaceuticals, products of personal care and endocrine disruptors are discussed as well as their origin and means of entry to the environment. Chapter 2 describes the development of a separation method for the determination of eight pharmaceuticals and endocrine disruptors substances with acidic character (diclofenac, bezafibrate, fenoprofen, ibuprofen, ketoprofen, naproxen, gentisic and salicylic acids) in a single run using capillary electrophoresis with on line sample enrichment (analyte stacking with large sample volume injection) in electrolytes composed of 30 mmol L-1 sodium tetraborate at pH 9.3 and 5 mmol L-1 Brij 35. The proposed method reached limits of detection between 2 µg L-1 (naproxen) and 80 µg mL-1 (ibuprofen). In Chapter 3, a CE separation method for the determination of nine pharmaceuticals and hormones with neutral and basic character (fluoxetin, trimethoprim, diazepam, carbamazepine, propranolol, clofibrate, fenofibrate, ethynylestradiol and estrone) was exploited. As preconcentration strategy, micelle stacking with large sample volume injection was performed. Limits of detection in the order of 9 µg L-1 were reached with electrolytes composed of 30 mmol L-1 phosphoric acid, 40 mmol L-1 sodium dodecylsulfate, 20% (v,v) acetonitrile and 0.1% (v,v) triethylamine. In Chapter 4, the physicochemical parameters associated with the solid phase extraction technique, such as sorbent type, breakthrough volume, elution volume, extraction cartridge rinse, among others, were evaluated. Optimum sample clean up and off line preconcentration conditions combined with the optimum on line preconcentration and separation conditions described in Chapters 2 and 3, for all substances under consideration, were applied to the analysis of real surface water samples collected at the Reservoir Billings (Sao Paulo state, Brazil). The combined method reached concentrations in the order of 500 ng L-1, with satisfactory recoveries (58 88%) for complex environmental matrices. In Chapter 5, a method for the analysis of alkyl p-hydroxybenzoates, substances used as preservatives in several products of personal care, was developed using capillary electrophoresis associated with on line (stacking with large volume injection) and off line (SPE) preconcentration strategies. The proposed method, which used 40 mmol L-1 glycine and 40 mmol L-1 triethylamine as electrolyte, was applied to the analysis of alkyl p-hydroxybenzoates in surface water, reaching 4 - 6 µg L-1 concentrations. Chapter 6 describes the development of a CE method for de analysis of linear alkylbenzene sulfonates (LAS) and homologues, surfactants commonly used in the composition of detergents of industrial and domestic use. As separation electrolyte, 60 mmol L-1 TRIS, 30 mmol L-1 HIBA, 15 mmol L-1 Brij 35 and 40% (v,v) acetonitrile was used. A solid phase preconcentration extraction step in C18 was employed and a total LAS concentration of 1.09 mg L-1 was found in a sample obtained from the effluent of a sewage treatment plant. In Chapter 7, a CE-MS (ion trap) method was developed for the analysis of cimetidine, propranolol, salbutamol, trimethoprim and methoclopramide in fortified surface water samples collected in the Reservoir Billings (Sao Paulo state, Brazil) and previously enriched by SPE (PS-DVB). The method reached concentrations of c.a. 40 µg L-1. Finally, in Chapter 8, a method based on high-performance liquid chromatography coupled with two different mass spectrometers: a triple quadrupole and a triple quadrupole with linear ion trap). Several pharmaceuticals were investigated in surface water samples collected from the Reservoir Billings (Sao Paulo state, Brazil). With the LC-MS/MS (triple quadrupole) system, carbamazepine was found in a non treated sample (just a filtration step prior to injection was performed) in a concentration level of 20 ng L-1. It is worth mentioning that for carbamazepine, a LOD of 400 fg L-1 was found, without any preconcentration sample treatment
69

\"Verificação da janela de detcção do etilglicuronídeo urinário entre usuários crônicos e bebedores sociais de etanol por cromatografia em fase gasosa acoplada à espectrometria de massas\" / Detection range verification of urinary ethyl glucuronide between chronic ethanol users and social drinkers by gas chromatography/mass spectrometry analysis

Marin, Ana Verónica Flores 06 July 2006 (has links)
A janela de detecção de etilglicuronídeo (EtG) parece variar de acordo com a intensidade de consumo de etanol. Assim sendo, o objetivo do presente trabalho foi desenvolver e validar uma metodologia empregando extração em fase sólida e GC-MS para a determinação de EtG urinário, no sentido de verificar sua janela de detecção entre um grupo de bebedores sociais e usuários crônicos. Os limites de detecção e quantificação obtidos foram 0,1 e 0,2 mg/L respectivamente. O método proposto demonstrou ser linear no intervalo de 0,2 a 100,0 mg/L (r2>0,99), exato e preciso. A janela de detecção de EtG em amostras de urina de cinco voluntárias após ingestão única e controlada de 0,5 g/kg de etanol variou de 24 a 35 horas. Amostras de urina foram coletadas de 14 pacientes internados em clínica de recuperação. Os resultados mostraram que a maioria deles provavelmente consumiu etanol, prejudicando a interpretação dos resultados. Nos casos em que a concentração urinária de EtG foi decaindo no decorrer do tempo, a janela de detecção variou de 72 a 120 horas. O método mostrou ser útil para monitorar a abstinência durante o tratamento de pacientes dependentes de etanol ou o consumo após uma única exposição em baixa dose. / The detection range of the ethylglicuronide (EtG) seems to vary in accordance to the intensity of ethanol consumption. Thus, the objective of the present work was to develop and validate a method using extraction in solid phase and GCMS for the determination of urinary EtG, in order to verify its detection window in a group of social drinkers and chronic ethanol users. The limits of detection and quantification were 0,2 and 0.1 mg/L, respectively. The method showed to be linear in the interval of 0,2 to 100,0 mg/L (r2>0,99), and presented good accuracy and precision. The urinary EtG detection range in samples of five volunteers after controlled ingestion of 0,5 g/kg of ethanol varied between 24 to 35 hours. Urine samples were also collected from 14 patients from a recovery clinic. The results showed that the majority of them probably consumed ethanol, which compromised the interpretation of the results. In the cases where the urinary concentration of EtG decayed with time, the detection window varied from 72 to 120 hours. The method showed to be useful to monitor the ethanol abstinence during treatment of alcoholic patients or the consumption of only one ethanol low dose.
70

Desenvolvimento de procedimento analítico para a determinação de ácido salicílico em materiais vegetais explorando cromatografia por injeção sequencial / Development of an analytical procedure for the determination of salicylic acid in plant materials exploiting sequential injection chromatography

Marcia Otto Barrientos 24 July 2015 (has links)
A cromatografia por injeção sequencial com extração em fase sólida (EFS) em linha foi explorada para a determinação de ácido salicílico em amostras vegetais. Uma mini coluna de polietileno, preenchida com sílica funcionalizada C18, foi utilizada para EFS, com tampão fosfato pH 5,2 como eluente. O eluato foi diretamente transferido para a separação cromatográfica em uma coluna monolítica C18, utilizando solução de acetonitrila/tampão acetato pH 4,75 (5:95, v/v) como fase móvel. A detecção foi realizada por fluorescência com excitação em 298 nm e emissão em 406 nm. Os sinais analíticos foram baseados na altura do pico cromatográfico referente ao ácido salicílico em um tempo de retenção de 9.0 min. Os limites de detecção (99,7% de confiança) e quantificação foram estimados em 80 e 240 ?g L-1, respectivamente. A precisão foi estimada através do coeficiente de variação intradia (n = 10) em 0,99% e interdia (3 dias) em 3,6%. A resposta foi linear até 8,0 mg L-1 (r = 0,996). A resolução em relação aos demais componentes da matriz, o número de pratos e a altura equivalente a um prato foram estimados em 6,0; 3980 e 12,6 ?m, respectivamente. Utilizando calibração pelo método das adições de padrão, foram estimadas recuperações entre 74,2 e 96,4% em 4 amostras de folhas de soja. Com estes resultados conclui-se que o procedimento é adequado à determinação de ácido salicílico nos materiais vegetais com a remoção de interferentes em linha, tendo as vantagens de ser um procedimento rápido (ca. 17 min por determinação), limpo (consumo de ca. 320 ?L de acetonitrila por determinação), de custo relativamente baixo, suficientemente sensível e seletivo / Sequential injection cromatography with on-line solid phase extraction (SPE) was explored for the determination of salicylic acid in vegetable samples. A polyethylene column filled with C18-bonded silica was used for SPE, with a phosphate buffer pH 5.2 as eluent. The treated extract was directly sent towards chromatographic separation in a C18 monolithic column with an acetonitrile/acetate buffer solution, pH 4,75 (5:95, v/v) as mobile phase before fluorescence detection (excitation at 298 nm and emission at 406 nm). The analytical signals were based on peak height at the 9.0 min retention time. Limits of detection (99.7% confidence level) and quantification were estimated at 80 and 240 ?g L-1. Precision was estimated through intraday coefficient of variation (n = 10) at 0.99% and interday (3 days) at 3.6 %. A linear response up to 8.0 mg L-1 was estimated (r = 0.996). Resolution, number of plates and the height equivalent to one plate were estimated at 6.0, 3980 and 12,6 ?m, respectively. With calibration by the standard additions method recoveries within 74.2 and 96.4 % were estimated to four soy leaves samples. Thus, the procedure is suitable for the determination of salicylic acid in the extracts with on-line removal of interferences, being a rapid (ca. 17 min per determination), clean (ca. 320 ?L of acetonitrile by determination), inexpensive, and suitably sensitive and selective

Page generated in 0.1061 seconds