• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 55
  • Tagged with
  • 55
  • 55
  • 48
  • 39
  • 35
  • 33
  • 29
  • 27
  • 26
  • 16
  • 14
  • 13
  • 12
  • 12
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Determinação de cobre, manganês e cádmio em por espectrometria de absorção atômica com forno de grafite / Determination of copper, manganese and cadmium in honey by graphite furnace atomic absorption spectrometry

Paes, Lorena Cristine, 1980- 19 October 2007 (has links)
Orientador: Solange Cadore / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-08-10T02:39:07Z (GMT). No. of bitstreams: 1 Paes_LorenaCristine_M.pdf: 387202 bytes, checksum: 46a0d9c60b50d24a3a34de8a99f50153 (MD5) Previous issue date: 2007 / Resumo: Visando o desenvolvimento de um método analítico para uma matriz heterogênea de interesse comercial e ambiental e, também, a fim de acrescentar novas informações sobre o mel nacional, este trabalho avaliou diferentes estratégias de tratamento do mel, diferentes modificadores químicos e otimizou os parâmetros instrumentais para a determinação de cobre, manganês e cádmio, por Espectrometria de Absorção Atômica com Forno de Grafite. O tratamento do mel com banho de ultrasom foi o procedimento mais adequado para o preparo da amostra, quando comparado às mineralizações em forno de microondas e em placa de aquecimento, bem como à solubilização com hidróxido de tetrametilamônio, devido à simplicidade e rapidez. Foi necessário o uso de peróxido de hidrogênio como modificador químico para aumentar a eficiência da eliminação da matriz nas determinações dos analitos de interesse, além do uso de 10 µg de Mg(NO3)2 como modificador químico para determinação de Mn e de 5µg de NH4H2PO4 como modificador químico para determinação de Cd. Os métodos otimizados apresentaram precisão, sensibilidade e repetibilidade adequadas e foram obtidas recuperações entre 70 e 90 %, o que indica uma exatidão satisfatória. As quantidades dos analitos nos méis brasileiros de diferentes procedências variaram entre 0,020 e 0,17 µg g de Cu, entre 0,39 e 11,9 µg g de Mn e foram menores que 6 ng g no caso do Cd. Observou-se que as amostras analisadas não são contaminadas com Cd e as altas concentrações de Mn confirmam que o mel brasileiro pode ser considerado uma boa fonte nutritiva deste elemento / Abstract: Different strategies for sample preparation, the optimization of instrumental parameters and the evaluation of different chemical modifiers for the determination of cadmium, copper and manganese in honey by graphite furnace atomic absorption spectrometry were developed. Honey is a heterogeneous matrix, which has great commercial and environmental importance. However, few studies concerning its mineral content have been carried out in Brazil. In this work the use of an ultra sonic bath was compared with digestion by microwave radiation or on a hot plate as well as solubilization with tetramethylammonium hydroxide. The best procedure for honey is that using ultrasound, considering its simplicity and speed of analysis. Hydrogen peroxide was used as chemical modifier together with 10 µg Mg(NO3)2 or 5 µg de NH4H2PO4 for the determination of Mn or copper, respectively. Satisfactory precision, sensitivity and accuracy as well as recoveries in the range of 70-90 % were obtained. Analyte concentrations in Brazilian honey, from different regions, varied between 0.020 to 0.17 µg g for Cu, and 0.3 to 11.9 for Mn. For Cd, values below 6 ng g were found. Brazilian honeys were not contaminated with Cd and may be considered a good source of manganese / Mestrado / Quimica Analitica / Mestre em Química
32

Desenvolvimento de estratégias analíticas usando espectrometria de absorção atômica para avaliar a composição de copos de liga peltre e lixiviação de cádmio, chumbo e antimônio

Dessuy, Morgana Bazzan January 2011 (has links)
Neste trabalho foram desenvolvidos diferentes métodos analíticos usando espectrometria de absorção atômica (AAS). Primeiramente, foi desenvolvido um método para a determinação sequencial de chumbo e antimônio, em liga peltre, via AAS de alta resolução com fonte contínua por chama. Os resultados demonstraram que as amostras contêm chumbo, o que vai de encontro à informação dos fabricantes de que seus produtos são livres de chumbo. Posteriormente, foram desenvolvidos métodos, via AAS por forno de grafite, para avaliar a lixiviação de cádmio e chumbo de copos de peltre para ácido acético 3%, cachaça, cerveja, vinho branco e tinto e vinagre tinto. Foi possível empregar o mesmo programa de aquecimento e modificador químico para determinação direta de cádmio e chumbo nas diferentes matrizes e, padrões aquosos para calibração. Também foi desenvolvido um método analítico, via AAS por geração de hidretos, para avaliar a lixiviação de antimônio dos copos de peltre para uma solução de ácido acético 3%. O método desenvolvido se mostrou eficiente para a determinação de antimônio em amostras contendo elevadas concentrações de estanho, também formador de hidreto. Os métodos analíticos propostos neste trabalho podem ser utilizados como ferramenta para uma investigação mais detalhada da lixiviação de cádmio, chumbo e antimônio de utensílios domésticos de peltre. / In this work it was developed different analytical methods using atomic absorption spectrometry (AAS). Firstly, it was developed a method for the sequential determination of antimony and lead, in pewter sample, using high resolution continuum source flame AAS. The results showed that samples contain lead. This affirmation goes against manufacturer which says their products are lead free. After, it was developed a method via graphite furnace AAS, to evaluate cadmium and lead leaching from pewter cups to 3% acetic acid, sugar cane spirit, beer, red wine, white wine and vinegar. It was possible to employ the same heating program and chemical modifier for the direct determination of cadmium and lead in the different liquids and, aqueous standards for calibration. It was, also, developed an analytical method, using hydride generation AAS, to evaluate antimony leaching from pewter cups to a 3% acetic acid solution. The developed method was efficient for antimony determination in samples containing high tin concentrations, also hydride forming element. The analytical methods proposed in this work can be used as a tool to a more detailed investigation regarding antimony, cadmium and lead leaching from pewter utensils.
33

Desenvolvimento de métodos analíticos para determinação de níquel e vanádio em petróleo por espectrometria de absorção atômica em forno de grafite

Damin, Isabel Cristina Ferreira January 2005 (has links)
Neste trabalho foram investigados diferentes métodos de preparação de amostra para a determinação de níquel e vanádio em óleo cru usando a espectrometria de absorção atômica com forno de grafite (GF AAS). Investigou-se o uso de xileno como diluente, o qual foi inadequado devido à baixa estabilidade de níquel nas soluções e resultando na contaminação do equipamento. As soluções diluídas em isobutilmetilcetona apresentaram melhor estabilidade, mas não houve reprodutibilidade das medidas com os padrões orgânicos de níquel. Melhores resultados foram obtidos com emulsões óleo-em-água, usando Triton X-100 como surfactante. Também foi estudado o uso de padrões aquosos (inorgânicos) para o preparo das emulsões. Após o estabelecimento de curvas de pirólise para padrão e amostra de óleo cru, observou-se diferença no comportamento térmico do níquel na matriz de óleo cru. Foi então realizada uma investigação usando um espectrômetro de absorção atômica com fonte contínua de alta resolução (HR-CS AAS), equipamento com elevada capacidade de correção de fundo, e constatou-se que cerca de 50 % do analito é perdido em temperaturas abaixo de 400 ºC, enquanto que o restante é termicamente estável até pelo menos 1200 ºC. A fim de resolver o problema de perda de níquel volátil, foi investigado o uso de paládio como modificador químico. Através de curvas de pirólise com e sem paládio, observou-se que a mesma perda também ocorreu para o vanádio. Após a otimização da melhor quantidade de paládio, verificou-se que foi necessária uma quantidade de 20 µg de paládio para estabilização de níquel e vanádio. A determinação de níquel e vanádio total em amostras de óleo cru foi realizada usando-se paládio como modificador químico. A especiação destes elementos foi possível através da determinação das espécies estáveis, provavelmente compostos salinos não porfirínicos de níquel e vanádio, sem a adição de paládio, e a fração de compostos voláteis (provavelmente porfirinas de níquel e vanádio) foi calculada por diferença. Estabeleceram-se as figuras de mérito obtendo-se valores de massa característica de 19 e 33 pg e limite de detecção de 43 e 113 pg para níquel e vanádio, respectivamente. Esses resultados são compatíveis com dados reportados na literatura. A exatidão deste procedimento foi verificada pela análise dos materiais de referência certificados de metais traço em óleo residual (SRM 1634c) para níquel e vanádio e o petróleo (RM 8505) somente para vanádio e também por comparação com os resultados obtidos por HR-CS AAS para várias amostras de óleo cru. A aplicação do teste estatístico t-student aos resultados de níquel e vanádio total obtidos por GF AAS e HR-CS AAS mostrou que os mesmos não são significativamente diferentes a um nível de 95% de confiança.
34

Investigação do comportamento de modificadores químicos para fósforo em forno de grafite usando espectrometria de absorção atômica de fonte de linha e fonte contínua de alta resolução

Dessuy, Morgana Bazzan January 2007 (has links)
Neste trabalho espectrometria de absorção atômica de fonte de linha (LS AAS) e de fonte contínua com alta resolução (HR-CS AAS) foram empregadas para investigar alguns modificadores, citados na literatura, para a determinação de fósforo usando forno de grafite. Modificadores químicos são necessários para produzir fósforo atômico e evitar a formação de subóxidos e outras moléculas voláteis. Com o emprego da HR-CS AAS ficou claro que, sem a adição de modificador, átomos de fósforo são formados somente numa reação secundária na parede do tubo. A medida de absorção, no início da fase de atomização, é inteiramente devido à molécula de PO. Paládio, paládio misturado com cálcio e lantânio, propostos como modificadores químicos para determinação de fósforo, foram os que produziram predominantemente fósforo atômico. Estes modificadores levaram, ainda a uma maior sensibilidade, em comparação com aquela obtida quando fluoreto de sódio foi empregado. O corretor de fundo de deutério não é capaz de corrigir eficientemente o fundo estruturado devido à PO, conseqüentemente, muitos dos resultados obtidos com LS AAS são artefatos. Constatou-se que HR-CS AAS é uma ferramenta bastante adequada para elucidar o comportamento do fósforo, podendo ser aplicada para outros elementos, pois toda a vizinhança da linha analítica é visível à alta resolução. / In this work line-source (LS) and high-resolution continuum source atomic absorption spectrometry (HR-CS AAS) have been used to investigate some modifiers recommended in the literature for the determination phosphorus in a graphite furnace. Modifiers are necessary to produce phosphorus atoms and to avoid the formation of volatile suboxides and other molecules. Using HR-CS AAS it has been found that, without the addition of a modifier, phosphorus atoms are only formed in a secondary reaction on the wall of the graphite tube. The absorption measured at the beginning of the atomization stage is not due to phosphorus atoms, but to the PO molecule. Palladium, with or without the addition of calcium, and lanthanum, used as modifiers, produced predominantly atomic phosphorus. With these modifiers the sensitivity was also higher than that obtained with the sodium fluoride modifier. Deuterium background correction is not capable of correcting efficiently for the structured background due to PO and, consequently, many of the results obtained with LS AAS are artifacts. HR-CS AAS has been found to be an extremely useful tool to elucidate the behavior of phosphorus, and it might be equally useful for other analytes due to the visibility of the vicinity of the analytical line at high resolution.
35

Desenvolvimento de métodos analíticos de rotina para análise de grãos de café verde utilizando amostragem sólida por espectrometria de absorção atômica em forno de grafite

Oleszczuk, Nédio January 2008 (has links)
O desenvolvimento de métodos para a determinação de manganês, cobre, cobalto e cádmio em café verde, usando amostragem direta por espectrometria de absorção atômica com forno de grafite, foi o principal objetivo do projeto. A motivação do estudo deveu-se ao fato que poucos elementos são necessários para a determinação da origem do café verde, não necessitando, assim, de técnicas multielementares. Manganês, cobre e cobalto foram escolhidos como elementosteste pois foram significativos em prévias investigações; cádmio foi incluído devido à sua toxicidade. Para a determinação de Mn, Co e Cd foi possível utilizar calibração versus padrões aquosos, enquanto que para a determinação de Cu foi necessário o uso de materiais de referência certificados (CRM). Os limites de detecção foram 0,012, 0,006, 0,004 e 0,001 μg g-1 para Mn, Cu, Co e Cd respectivamente. Vários CRM botânicos e amostras pré-analisadas de café verde foram utilizados na validação do método; espectrometria de emissão ótica por plasma indutivamente acoplado foi usada como método de referência. Não foi observada diferença significativa entre os resultados obtidos com o método proposto e os valores certificados ou determinados independentemente. Sete amostras de café verde brasileiro foram analisadas, porém não foi tentado correlacionar os valores com a origem, já que apenas uma amostra por plantação foi analisada. / A method has been developed for the determination of manganese, copper, cobalt and cadmium in green coffee using direct solid sampling graphite furnace atomic absorption spectrometry. The motivation for the study was that only a few elements might be necessary to determine the origin of green coffee and no multielement technique is necessary. Manganese, copper and cobalt were chosen as test elements as they have been found significant in previous investigations; cadmium was included because of its toxicity. Calibration against aqueous standards could be used for the determination of Mn, Co and Cd, but calibration against solid certified reference materials (CRM) was necessary for the determination of Cu; the limits of detection were 0,012, 0,006, 0,004 and 0,001 μg g-1 for Mn, Cu, Co and Cd respectively. Several botanical CRM and pre-analyzed samples of green coffee were used for method validation; inductively coupled plasma optical emission spectrometry was used as reference method. No significant difference was found between the results obtained with the proposed method and certified or independently determined values. Seven samples of Brazilian green coffee have been analyzed, but no attempt was made to correlate the values with the origin, as only one sample was analyzed for each growing area.
36

Determinação de metais em fertilizantes e calcário utilizando análise direta por espectrometria de absorção atômica com forno de grafite.

Borges, Aline Rocha January 2014 (has links)
Neste trabalho, foi investigada a viabilidade do use da analise direta por espectrometria de absorcdo atomica corn forno de grafite (GF AAS) para a determinacdo de metais em fertilizantes e calcario. Foi desenvolvido um metodo para a determinacdo de chumbo utilizando analise por suspensao (S1S) por GF AAS corn corretor de fundo baseado no efeito Zeeman (S1S-GF AAS-ZBC). As interferencias espectrais observadas foram, em parte, resolvidas usando espectrometria de absorcao atomica de alta resolucao corn fonte continua (HR-CS AAS) corn aplicacao de correcdo por minimos quadrados. Posteriormente, foi desenvolvido um metodo para a determinacao de cadmio por S1S-HR-CS GF AAS, neste caso, o sinal de fundo foi resolvido corn a aplicacao da correcdo automatica e nao foi observada interferencia espectral. A analise direta de solidos (SS) foi utilizada na determinacao de cromo e talio por GF AAS-ZBC, e os resultados, comparados por SS-HRCS GF AAS, na maioria dos casos, foram compativeis. Entretanto, na determinacao de tali°, devido a alguma interferencia espectral desconhecida, algumas amostras somente puderam ser analisadas por SS-HR-CS GF AAS. Nenhuma das amostras investigadas apresentou concentracao de chumbo, cadmio e cromo maior do que o estipulado pela legislacao brasileira, a qual nab estabelece um limite maximo para tali°. / In this work, was investigated the feasibility of using analysis direct graphite furnace atomic absorption spectrometry (GF AAS) for the determination of metals in fertilizer and limestone. A method was developed for the determination of lead using slurry sampling (S1S) with GF AAS with Zeeman-effect background correction (S1S-GF AAS-ZBC). The observed spectral interferences could be overcome, in part, using high-resolution continuum source (HR-CS AAS) with least-squares background correction. Posteriorly, a method was developed for the determination of cadmium using S1S-HR-CS GF AAS; in this case the background signal could be resolved using automatic correction and no spectral interferences were observed. The direct solid sample analysis (SS) was used for the determination of chromium and thallium with GF AAS-ZBC, and the results were compared with SS-HR-CS GF AAS. In most cases, the values were compatible; however, in some samples, thallium could only be determined using SS-HR-CS GF AAS due to an unknown spectral interference. None of the investigated samples had a cadmium, chromium or lead concentration exceeding the limits given by Brazilian legislation; no limits are given for thallium.
37

Determinação de elementos-traço em amostras de nitreto de alumínio e nitreto de silício por análise direta de amostras sólidas em espectrometria de absorção atômica com forno de grafite / Determination of trace elements in aluminium nitride and silcon nitride using direct solid sampling grafite furnace atomic absorption spectrometry

Mattos, Julio Cezar Paz de 28 March 2008 (has links)
Importadora e Exportadora de Medidores Polimate Ltda / A graphite furnace atomic absorption spectrometry method using direct solid sampling has been developed for the determination of Cr, Cu, Fe, K, Mn, Sb and Zn in powdered AlN and Si3N4. Owing to the vaporization of AlN during atomization step, different approachs to avoid the interferences caused by high background arising from matrix thermal decomposition, were investigated. A comparison between the performance of deuterium background correction system and the based on Zeeman effect for the analysis of AlN sample was carried out. For silicon nitride analysis, although during atomization of all analytes, excluding Zn, conversion of Si3N4 into Si0 and SiC was taking place and its essential part vaporized as different species, no problems the resultant background was properly corrected. The calibration for both samples was carried out using aqueous standard solutions. In the determination of Fe in Si3N4 powders, graphite powder was used in order to achieve quantitative vaporization and also to increase the lifetime of the platform, this procedure was also advantageous for the determination of Cr and Cu. During AlN analysis, the application of graphite or other chemical modifiers was unnecessary. For AlN analysis, it was possible to apply sample amounts up to 16 mg for Sb, the relative standard deviations (n = 5) were between 2 and 16%. The Achieved limits of detection were between 7 (Sb and Zn) and 2000 ng g-1(Fe). During Si3N4 analysis sample masses up to 2 mg could be applied per analysis cycle, the relative standard deviations (n = 5) were between 5 and 18% (n = 5). For the most sensitive conditions, limits of detection between 0.1 (Zn) and 213 ng g-1 (Fe) are achievable for the analysis of Si3N4. The accuracy was checked by comparison of the results with those obtained using other methods including neutron activation analysis whereby good to reasonable agreement was achieved. / Neste trabalho, foram desenvolvidos métodos para a determinação de Cr, Cu, Fe, K, Mn, Sb e Zn em AlN e Si3N4, usando espectrometria de absorção atômica com forno de grafite e análise direta de amostras sólidas. Devido à vaporização da matriz de AlN durante a etapa de atomização, diferentes estratégias para evitar as interferências causadas pelo sinal de fundo proveniente da decomposição térmica da matriz foram investigadas. Foi feita uma comparação entre os desempenhos dos corretores de fundo baseados em lâmpada de deutério e no efeito Zeeman para a determinação dos elementos citados em AlN. Embora durante a etapa de atomização (exceto para Zn) o Si3N4 seja parcialmente convertido em Si0 e SiC, acompanhada da vaporização parcial de outras espécies químicas, não foram constatados problemas com respeito a intensidade dos sinais de fundo. A calibração dos instrumentos, para ambas amostras, foi sempre feita usando soluções de referência aquosas. Para a determinação de Fe em Si3N4, pó de grafite foi usado para alcançar vaporização quantitativa, bem como para aumentar a vida útil da plataforma. Este procedimento foi vantajoso também para a determinação de Cr e Cu. Durante a análise de AlN, a aplicação de grafite ou qualquer outro modificador químico foi desnecessária. Para a análise de AlN, foi possível o uso de até 16 mg de amostra para Sb, os desvio padrão relativo (n = 5) foram entre 2 e 16%. Os limites de detecção atingidos foram entre 7 (Sb e Zn) e 2000 ng g-1(Fe). Durante a análise de Si3N4 foram aplicadas massas de amostra até 2 mg, os desvios padrão relativos (n = 5) foram entre 5 e 18% (n = 5). Usando as melhores condições, limites de detecção entre 0,1 (Zn) e 213 ng g-1 (Fe) foram atingidos para a análise de Si3N4. A exatidão dos métodos foi avaliada através da comparação com os resultados obtidos por outras técnica independentes, incluindo a análise por ativação neutrônica, obtendo-se boas concordâncias para vários elementos.
38

Desenvolvimento de método analítico para determinação de elementos-traço em gasolina por espectrometria de absorção atômica com forno de grafite utilizando extração em papel-filtro

Kolling, Leandro January 2018 (has links)
Neste trabalho, investigou-se um método simples e prático para a determinação de Pb e Ni em gasolina automotiva utilizando análise de sólidos por espectrometria de absorção atômica de alta resolução com fonte contínua em forno de grafite. No método proposto, discos de papéis-filtro são usados para pré-concentrar e armazenar Pb, Ni e outros elementos-traço de amostras de diferentes tipos de gasolina automotiva. Para isso, um volume de amostra é depositado sobre papel-filtro previamente adaptado em uma fôrma de politetrafluoretileno e seco sob aquecimento brando. Em seguida, este papel-filtro embebido em gasolina é cortado em discos menores (com o auxílio de um perfurador) ou pulverizado, para a determinação dos analitos. Na otimização do método, foram investigados o uso de modificador químico, programa de temperatura, efeito cromatográfico e o volume de amostra. Para calibração, foi investigado o uso de padrões em meios orgânico e inorgânico, bem como o uso de calibração externa e interna. Todas as curvas de calibração externa apresentaram coeficientes de determinação superiores a 0,99 e sensibilidades entre 0,603-0,669 s ng-1 para o Pb e 0,375-0,397 s ng-1 para o Ni Usando condições otimizadas os seguintes parâmetros de mérito foram obtidos: massas características, limites de detecção e limites de quantificação de: 6 e 11 pg; 0,5 e 2,1 μg L-1; e 1,8 e 6,8 μg L-1 para Pb e Ni, respectivamente. A frequência analítica foi de 3 amostras por hora (em quintuplicata). Testes de recuperação foram realizados para as amostras e as melhores recuperações foram obtidas com o uso do papel pulverizado. Para esse método, os valores obtidos ficaram na faixa de 90-111% para Pb e de 101-114% para Ni, indicando a ausência de efeito de matriz do papel-filtro impregnado com amostra de gasolina. A exatidão do método foi avaliada com um método comparativo, o qual utiliza o atomizador de filtro de grafite e um material de referência certificado diluído com uma amostra de gasolina livre de analitos. O uso do papel-filtro apresentou várias vantagens, não apenas como uma ferramenta simples e barata para armazenamento e transporte de amostras de gasolina, mas também permitiu a pré-concentração de diferentes analitos, uma vez que um grande volume de amostra pode ser utilizado. Além disso, o papel-filtro é um substrato adequado, permitindo a medição direta em um forno de grafite. / In this study, a simple and practical method for the determination of Pb and Ni in automotive gasoline by solid sampling high-resolution continuum source graphite furnace atomic absorption spectrometry was investigated. In the proposed method, pieces of filter papers were used to preconcentrate and store Pb, Ni and other trace elements from different automotive gasoline samples. For this, a volume of sample was deposited and dried out on a filter paper disk previously adapted into a polytetrafluoroethylene mold, and then the gasoline-embedded filter paper was either cut in small pieces or even pulverized and introduced directly into the graphite furnace for trace elements determination. Temperature program, use of chemical modifier, chromatographic effect and volume of sample were investigated. Calibration curves using organic and inorganic standards of the analytes as well as external and the internal calibration methods were evaluated. All external calibration curves showed determination coefficients higher than 0.99 and sensitivities between 0.603 - 0.669 s ng-1 for Pb and 0.375 - 0.397 s ng-1 for Ni using calibration Using optimized conditions, characteristic masses, limits of detection, and limits of quantification of 6 and 11 pg; 0.5 and 2.1 g L-1; and 1.8 and 6.8 g L-1 for Pb and Ni, respectively were achieved. All the figures of merit were achieved using optimized conditions. The sample throughput was 3 samples per hour (five replicates analysis). Spike-recovery tests were accomplished for 9 samples and the best recovery values were obtained with the pulverized filter paper. For this method, the recovery ranged between 90-111% for Pb, and 101-114% for Ni, indicating the absence of matrix effect from the gasoline-embedded filter paper. The accuracy of the method was evaluated with a comparative method, which uses the transversally heated filter atomizer, and a certified reference material diluted with a gasoline sample free of the target analytes. The use of filter paper showed to be a simple and inexpensive tool for storage and transportation of gasoline samples, but also it allowed the pre-concentration of the analytes, since a larger volume of sample can be used. Besides, the filter paper is a suitable substrate that allows direct measurement into a graphite furnace.
39

Determinação direta de elementos potencialmente tóxicos em arroz por GF AAS: desenvolvimento de métodos e aplicações / Direct determination of potentially toxic elements in rice by GF AAS: methods development and applications

Silvestre, Daniel Menezes 26 March 2013 (has links)
O arroz é um dos alimentos mais consumidos no mundo, caracterizando-se como a base da alimentação para mais da metade da população mundial. De acordo com a Organização Mundial da Saúde (WHO), a ingestão de alimentos contaminados é uma das principais vias de absorção de elementos potencialmente tóxicos pelo ser humano. Por esse motivo, órgãos de fiscalização têm estabelecidos limites máximos permitidos desse tipo de elemento nos alimentos. Nesse sentido, o desenvolvimento de métodos e aplicações visando à determinação de elementos com caráter tóxico, tais como o Al, As, Cd e Pb em alimentos é de suma importância. Nesse projeto, foram desenvolvidos métodos para determinações diretas de Al, As, Cd e Pb em arroz por espectrometria de absorção atômica com forno de grafite e amostragem direta de sólidos (SS-GF AAS) que tem se mostrado uma técnica promissora especialmente devido à sua elevada sensibilidade e detectabilidade, além de dispensar morosos processos de decomposição de amostra. A adequada otimização do programa de aquecimento aliado ao uso de modificadores químicos adequados possibilitou o uso de calibração aquosa. Parâmetros importantes como o tamanho de partícula, massa de amostra e segregação de analito foram investigados. Observou-se que partículas inferiores a 100 µm geravam resultados precisos. A massa mínima ideal de amostra de arroz a ser utilizada na análise foi em torno de 300 µg. A massa máxima recomendada foi 500 µg. Segregação de Al e Cd não foram observadas na amostra de arroz. A segunda parte do projeto envolveu a aplicação do método de análise desenvolvido em amostras de arroz comercializadas na cidade de São Paulo. Investigou-se também a influência dos processos de lavagem e cozimento dos grãos sobre a concentração de Al, As, Cd e Pb. Todas as 17 amostras de diversos tipos e marcas de arroz analisadas apresentaram concentrações de As, Cd e Pb abaixo dos limites estabelecidos por lei. Com relação ao Al, não há regulamentado o valor de limite máximo. As maiores concentrações desse elemento foram observadas nos grãos de arroz integral. O processo de lavagem removeu significativamente a concentração de Al e Pb na maioria das amostras, entretanto, o mesmo não foi observado para o Cd. O processo de cozimento diminuiu a concentração de Cd e Pb em parte das amostras, e um pequeno aumento na concentração do Al foi observado, o qual pode ser atribuído à contaminação pelo ambiente. O cozimento do arroz em frascos de vidro ou panelas a base de alumínio não alterou a concentração desse elemento no arroz, nem mesmo quando a panela de alumínio foi polida com palha de aço / Rice is a staple food for more than 40% of the world\'s population. Considering that the main reason of contamination by potentially toxic element occurs by food ingestion, World Health Organization (WHO) has been controlling the levels of some contaminants. In this context, development of methods and applications associated to determination of potentially toxic elements such as Al, As, Cd and Pb in food are important. In this work, methods for direct determination of Al, As, Cd and Pb in rice by solid sampling graphite furnace atomic absorption spectrometry (SS-GF AAS) were developed. Solid sampling-GF AAS has shown as a promising technique especially due to its high sensitivity and detectability and the possibility to practice direct analysis of solid samples, dismissing tedious and error prone sample preparation step. The adequate heating program optimization associated to the use of chemical modifier allowed direct rice analysis against aqueous calibration. The influence of some parameters, such as particle size, sample mass size and analyte segregation on the analytical results were investigated. Results showed that particle size smaller than 100 µm generated accurate results. The minimum sample mass size recommended for analysis was around 300 µg and the maximum sample mass size was around 500 µg. Segregation of Cd and Al was not observed in the rice sample. The second part of the work involved the analysis of 17 rice samples commercially available in São Paulo city. Influence of rice washing and cooking procedure on the Al, As, Cd and Pb concentrations was also investigated. Concentration of all analytes were lower than the maximum allowed by WHO in all samples. The highest concentrations of Al were found in coarse rice. The washing process reduced significantly the concentrations of Al and Pb in most samples, however, the same was not observed for Cd. Cooking process reduced the concentration of Cd and Pb for most samples, probably by volatilization. On the other hand, an increase in Al concentration was observed. This fact could be attributed to the sample contamination during cooking process. Rice cooked in glass or aluminum container presented the same concentration of Al, even when polished aluminum container was used. These results indicated that there is no translocation of Al from container to food
40

Proposta de método para determinação de Pt em sangue total visando o uso como biomarcador de exposição ambiental por veículos automotivos / A method for determination of Pt in whole blood in order to use as biomarker of environmental exposure by automotive vehicles.

Santos, Leandro Mota 19 June 2015 (has links)
Reflexo de um modo de vida que exige locomoção rápida e com um mínimo de conforto, atualmente, nas grandes metrópoles, há um grande número de veículos em circulação que emitem gases poluentes (hidrocarbonetos, CO e óxidos de nitrogênio - NOx). Para minimizar a emissão desses gases, os carros atuais são dotados de conversores catalíticos, formados pelos metais do grupo da platina, com a finalidade de converter gases nocivos em gases menos agressivos ao ambiente e ao homem. Porém, esses elementos constituintes dos conversores catalíticos podem ser expelidos para o ambiente, na forma de materiais particulados em suspensão, por volatilização ou junto com os gases da combustão. Desta forma, esses elementos podem acumular-se nos mais diversos ambientes. A utilização de amostras biológicas, tal como sangue, na investigação e no controle à exposição de elementos nos seres humanos vem sendo praticada há muito tempo. Estudos com materiais biológicos apontam que as concentrações de metais do grupo da Platina estão na ordem de ng/kg. Tais níveis de concentração representam um grande desafio para a Química Analítica, pois são muito baixos para que se tenham resultados com boa precisão e exatidão nas análises, mesmo utilizando técnicas muito sensíveis. Como alternativa para contornar os problemas, nas determinações destas baixas concentrações, etapas prévias de pré-concentração, com posterior determinação, vem sendo propostas com sucesso. Nessa pesquisa, para a pré-concentração dos analito, extração em ponto nuvem foi empregada com determinação por espectrometria de absorção atômica por forno de grafite. O procedimento da extração em ponto nuvem consiste em derivatizar os analitos em espécies hidrofóbicas por meio de um agente complexante, e extrair por micelas formadas a partir de um surfactante não iônico, induzidas por mudança de temperatura. Essa extração se baseia no fenômeno que ocorre com a formação de agregados micelares, quais apresentam caráter hidrofóbico. Foram estudados diferentes ligantes, e o melhor resultado para a extração foi obtido empregando-se o APDC (pirrolidina ditiocarbamato de amônio). Os parâmetros da extração em ponto nuvem otimizados para o melhor ligante foram: pH=7; 3,0x10-2 mol L-1 de APDC; 0,5 % m v-1 de Triton X-114; 60ºC durante 10 min de banho, 10 min de centrifugação e 50 mg L-1 Cu(II) como modificador químico. O método apresentou fator de enriquecimento de 24 vezes, mas o LOD (0,24 µg L-1) ficou muito acima dos valores apresentados em amostras de indivíduos expostos e não expostos. Adições de 1, 5 e 10 µg L-1 foram realizadas para avaliar a exatidão do método e apresentaram recuperações média de 91%. / Reflecting a way of life that requires fast displacement with a minimum of comfort, currently in big cities, there are a large number of vehicles that produce a large amount of waste gases (hydrocarbons, CO and nitrogen oxides - NOx) to atmosphere. To minimize the emission of these gases, current cars are equipped with catalytic converter, made of platinum group metals, which has the purpose of converting the noxious gases into less harmful gases to environment and man. However, these constituents of the catalytic converter can be expelled to the environment in form of particulates in suspension, or by volatilization along with the combustion gases. Thus, these elements can accumulate. Biological samples such as blood, urine, hair, nail, have been used for a long time in studies and control of human exposition to elements. Studies of biological materials indicate that the concentrations of platinum group metals are the order of ng/kg. Such concentration levels means a huge challenge for analytical chemistry, as they are too low to provide the necessary results with good precision and accuracy in the analysis, even using very sensitive techniques. As an alternative to overcome the problems in the provisions of these low concentrations, preconcentration methods, with subsequent determination has been proposed successfully. Cloud point extraction (CPE) was proposed in this work for pre-concentration of the analytes. CPE procedure consists in derivatizing the analytes into hydrophobic species by a complexing agent and extracts them trapped inside micelles formed from a nonionic surfactant, induced by temperature change. The cloud point extraction is based on the phenomenon that occurs with the formation of these hydrophobics aggregates by those micelles. Dithizone, DBTC, DMG, DDTC and APDC ligands were studied. The optimized parameters of cloud point extraction were: pH=7; 3,0x10-2 mol L-1 APDC; 0,5% m v-1 Triton X-114; 60 ºC while 10 min of termal bath and 10 min of centrifugation time. A Cu (II) 50 mg L-1 solution was used as a chemical modifier. The method was evaluated after optimized cloud point extraction\'s parameters conditions. It showed enrichment factor of 24-fold, but the limit of detection (0.24 µg L-1) was higher than the values expected to samples of exposed and non exposed individuals. A recovery test was done and a satisfactory recovery result was provided, up to 91%.

Page generated in 0.0316 seconds