• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 55
  • Tagged with
  • 55
  • 55
  • 48
  • 39
  • 35
  • 33
  • 29
  • 27
  • 26
  • 16
  • 14
  • 13
  • 12
  • 12
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Avaliação de métodos de preparo de amostras para decomposição de biodiesel e determinação de elementos químicos por espectrometria atômica

Dutra, Mauro Henrique Dartora January 2016 (has links)
Neste trabalho dois métodos de preparo de amostras para decomposição de bio-diesel foram avaliados para a posterior determinação de Cu e Ni por espectrometria de absorção atômica com forno de grafite (GF AAS). O primeiro método consistiu na de-composição ácida assistida por radiação micro-ondas em sistema fechado (MW-AD), que foi realizada com adição de HNO3 7 mol L-1 e 2 mL de H2O2 30% (m/m). O segun-do método de pré-tratamento avaliado foi a decomposição por via seca em forno mufla com programa de aquecimento até a temperatura máxima de 450 °C. O sólido resultante foi dissolvido em HNO3 1% (v/v). As temperaturas de pirólise e atomização para a téc-nica de GF AAS foram, respectivamente, 1000 ºC e 2000 ºC para Cu, e 1100 °C e 2300 °C para Ni. Os limites de detecção (LD) para Cu e Ni foram de 12,4 e 3,8 ng g-1 empre-gando o método de decomposição MW-AD. Enquanto que, para o método de decompo-sição por via seca os LD foram de 2,8 e 8,3 ng g-1 para Cu e Ni, respectivamente. A avaliação da exatidão foi efetuada a partir do ensaio de recuperação após adição de ana-lito ao biodiesel. As recuperações foram de 91 e 86% para o método MW-AD para Cu e Ni, respectivamente. Foram observadas perdas por volatilização com o emprego do mé-todo de via seca para Cu, com isso, a recuperação foi no máximo de 73%. / In this work, two methods for biodiesel digestion for determination of Cu and Ni by graphite furnace atomic absorption spectrometry (GF AAS) were evaluated. The microwave-assisted acid digestion (MW-AD) with the addition of 7 mol L-1 of HNO3 and 2 mL of H2O2 30% (m/m) was applied to biodiesel digestion. In addition, a dry ash method was applied to biodiesel digestion using a maximum temperature of 450 ºC. The inorganic residues were dissolved by addition of 1% (v/v) nitric acid. The optimiza-tion of temperature program was performed in the GF AAS for Cu and Ni using a sam-ple with standard addition. The pyrolysis and atomization temperatures were, respec-tively, 1000 ° C and 2000 ° C for Cu and 1100 ° C and 2300 °C for Ni. The limits of detection for Cu and Ni were 12,4 and 3,8 ng g-1, respectively, using a MW-AD meth-od. Using a dry ash method the limits of detection were 2,8 and 8,3 for Cu and Ni, re-spectively. The recoveries for Cu and Ni after MW-AD method were 91 and 86%, re-spectively. Using the dry ash method the recovery was 73% for Cu due to sample vo-latilization losses.
42

Desenvolvimento de procedimento para determinação direta de As, Cd, Pb e Cu por SS-GE ASS e avaliação de parâmetros da produção de material de referencia de tecido muscular de peixe visando ao controle ecotoxicológico

Chelegão, Rodrigo January 2009 (has links)
Orientadora: Profa. Dra. Cassiana Seimi Nomura. / Dissertação (mestrado) - Universidade Federal do ABC, Programa de Pós graduação em Ciência e Tecnologia - Química, 2009. / Organismos marinhos, como os peixes, vêm sendo intensamente utilizados como bioindicadores de contaminação para a avaliação de risco ecológico. Elementos potencialmente cancerígenos como As, Cd, Pb e Cu nesse tipo de amostra são utilizados como biomarcadores de poluição, fornecendo importantes informações na avaliação do risco à saúde humana. Nesse sentido, este trabalho teve como objetivo principal desenvolver um procedimento de microanálise direta de tecido muscular de peixe por espectrometria de absorção atômica com forno de grafite e amostragem direta de sólidos (SS-GF AAS) visando à determinação de As, Cd, Cu e Pb. A adequada otimização do programa de aquecimento aliada ao uso de modificadores químicos apropriados possibilitaram o emprego da curva analítica de calibração construída com solução aquosa. Sabendo que a toxicidade do As varia com a sua forma química, nesse trabalho também está apresentado o desenvolvimento de um método rápido e simples para a determinação de espécies orgânicas (AsB + DMA) e inorgânicas (As(III) e As(V)) de As, empregando simples extração da espécie orgânica com água. Avaliaram-se também alguns importantes parâmetros associados à produção de material de referência de tecido de peixe. A tilápia foi a espécie de peixe empregada para conduzir esses estudos. No entanto, somente Cu e Pb pôde ser determinado pelo método proposto. Procedimento de moagem, influência do tamanho de partícula e segregação das partículas foram os principais parâmetros avaliados. Dentre os procedimentos de moagem avaliados, a criogênica mostrou-se a mais adequada, uma vez que o frasco de nylon empregado na moagem em processador de alimentos causou uma severa contaminação da amostra com Pb. Estudos de homogeneidade mostraram que nos resultados da determinação de Cu, o tamanho e a segregação de partícula não são críticos. O material preparado possui homogeneidade de Cu e Pb garantida para massa de amostra inferior a 2 mg, podendo portanto, ser aplicada na microanálise. / Marine organisms, such as fishes, have been intensely used as bioindicators of contamination for environmental risk evaluation. In these kind of sample, potentially carcinogenic elements, such as, As, Cd, Cu and Pb, are used as pollution biomarkers, revealing important information of risk for human health. In this way, the aim of this work was the development of a procedure for direct microanalysis of fish tissue by solid sampling graphite furnace atomic absorption spectrometry (SS-GF AAS) for As, Cd, Cu and Pb determination. The heating program optimization associated to the appropriate use of chemical modifier become possible the use of aqueous calibration curve. As arsenic toxicity depends on the chemical form, this work also proposed a development of fast and simple method for the determination of organic (AsB and DMA) and inorganic (As(III) and As(V)) arsenic species. For this, a simple extraction procedure using water was used. Important parameters associated to the production of fish tissue reference material were also evaluated. The tilapia specie was used in this investigation. However, with this matrix, only Cu and Pb could be detected by the proposed method. Grinding process, particle size and segregation were the main parameters evaluated. Considering the grinding process, the cryogenic grinding presented the best results. The use of food grinder contaminated the sample with Pb. Homogeneity studies showed that particle size is not critical in Cu determination. The prepared sample presents homogeneity guaranteed for sample mass lower than 2 mg, becoming possible the application in microanalysis.
43

Avaliação de métodos de preparo de amostras para decomposição de biodiesel e determinação de elementos químicos por espectrometria atômica

Dutra, Mauro Henrique Dartora January 2016 (has links)
Neste trabalho dois métodos de preparo de amostras para decomposição de bio-diesel foram avaliados para a posterior determinação de Cu e Ni por espectrometria de absorção atômica com forno de grafite (GF AAS). O primeiro método consistiu na de-composição ácida assistida por radiação micro-ondas em sistema fechado (MW-AD), que foi realizada com adição de HNO3 7 mol L-1 e 2 mL de H2O2 30% (m/m). O segun-do método de pré-tratamento avaliado foi a decomposição por via seca em forno mufla com programa de aquecimento até a temperatura máxima de 450 °C. O sólido resultante foi dissolvido em HNO3 1% (v/v). As temperaturas de pirólise e atomização para a téc-nica de GF AAS foram, respectivamente, 1000 ºC e 2000 ºC para Cu, e 1100 °C e 2300 °C para Ni. Os limites de detecção (LD) para Cu e Ni foram de 12,4 e 3,8 ng g-1 empre-gando o método de decomposição MW-AD. Enquanto que, para o método de decompo-sição por via seca os LD foram de 2,8 e 8,3 ng g-1 para Cu e Ni, respectivamente. A avaliação da exatidão foi efetuada a partir do ensaio de recuperação após adição de ana-lito ao biodiesel. As recuperações foram de 91 e 86% para o método MW-AD para Cu e Ni, respectivamente. Foram observadas perdas por volatilização com o emprego do mé-todo de via seca para Cu, com isso, a recuperação foi no máximo de 73%. / In this work, two methods for biodiesel digestion for determination of Cu and Ni by graphite furnace atomic absorption spectrometry (GF AAS) were evaluated. The microwave-assisted acid digestion (MW-AD) with the addition of 7 mol L-1 of HNO3 and 2 mL of H2O2 30% (m/m) was applied to biodiesel digestion. In addition, a dry ash method was applied to biodiesel digestion using a maximum temperature of 450 ºC. The inorganic residues were dissolved by addition of 1% (v/v) nitric acid. The optimiza-tion of temperature program was performed in the GF AAS for Cu and Ni using a sam-ple with standard addition. The pyrolysis and atomization temperatures were, respec-tively, 1000 ° C and 2000 ° C for Cu and 1100 ° C and 2300 °C for Ni. The limits of detection for Cu and Ni were 12,4 and 3,8 ng g-1, respectively, using a MW-AD meth-od. Using a dry ash method the limits of detection were 2,8 and 8,3 for Cu and Ni, re-spectively. The recoveries for Cu and Ni after MW-AD method were 91 and 86%, re-spectively. Using the dry ash method the recovery was 73% for Cu due to sample vo-latilization losses.
44

Avaliação de métodos de preparo de amostras para decomposição de biodiesel e determinação de elementos químicos por espectrometria atômica

Dutra, Mauro Henrique Dartora January 2016 (has links)
Neste trabalho dois métodos de preparo de amostras para decomposição de bio-diesel foram avaliados para a posterior determinação de Cu e Ni por espectrometria de absorção atômica com forno de grafite (GF AAS). O primeiro método consistiu na de-composição ácida assistida por radiação micro-ondas em sistema fechado (MW-AD), que foi realizada com adição de HNO3 7 mol L-1 e 2 mL de H2O2 30% (m/m). O segun-do método de pré-tratamento avaliado foi a decomposição por via seca em forno mufla com programa de aquecimento até a temperatura máxima de 450 °C. O sólido resultante foi dissolvido em HNO3 1% (v/v). As temperaturas de pirólise e atomização para a téc-nica de GF AAS foram, respectivamente, 1000 ºC e 2000 ºC para Cu, e 1100 °C e 2300 °C para Ni. Os limites de detecção (LD) para Cu e Ni foram de 12,4 e 3,8 ng g-1 empre-gando o método de decomposição MW-AD. Enquanto que, para o método de decompo-sição por via seca os LD foram de 2,8 e 8,3 ng g-1 para Cu e Ni, respectivamente. A avaliação da exatidão foi efetuada a partir do ensaio de recuperação após adição de ana-lito ao biodiesel. As recuperações foram de 91 e 86% para o método MW-AD para Cu e Ni, respectivamente. Foram observadas perdas por volatilização com o emprego do mé-todo de via seca para Cu, com isso, a recuperação foi no máximo de 73%. / In this work, two methods for biodiesel digestion for determination of Cu and Ni by graphite furnace atomic absorption spectrometry (GF AAS) were evaluated. The microwave-assisted acid digestion (MW-AD) with the addition of 7 mol L-1 of HNO3 and 2 mL of H2O2 30% (m/m) was applied to biodiesel digestion. In addition, a dry ash method was applied to biodiesel digestion using a maximum temperature of 450 ºC. The inorganic residues were dissolved by addition of 1% (v/v) nitric acid. The optimiza-tion of temperature program was performed in the GF AAS for Cu and Ni using a sam-ple with standard addition. The pyrolysis and atomization temperatures were, respec-tively, 1000 ° C and 2000 ° C for Cu and 1100 ° C and 2300 °C for Ni. The limits of detection for Cu and Ni were 12,4 and 3,8 ng g-1, respectively, using a MW-AD meth-od. Using a dry ash method the limits of detection were 2,8 and 8,3 for Cu and Ni, re-spectively. The recoveries for Cu and Ni after MW-AD method were 91 and 86%, re-spectively. Using the dry ash method the recovery was 73% for Cu due to sample vo-latilization losses.
45

Extração seletiva por ponto nuvem para pré-concentração e especiação de arsênio inorgânico em matriz alimentícia empregando espectrometria de absorção atômica eletrotérmica em forno de grafite / Selective extraction by cloud point for preconcentration and speciation of inorganic arsenic in food using graphite furnace electrothermal atomic absorption spectroscopy

Costa, Bruno Elias dos Santos 29 July 2013 (has links)
Submitted by Luciana Ferreira (lucgeral@gmail.com) on 2015-01-30T11:57:26Z No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Dissertação - Bruno Elias dos Santos Costa - 2013.pdf: 2053959 bytes, checksum: 6af8dff43a9a4b548490b5b15b557b8a (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2015-01-30T14:45:37Z (GMT) No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Dissertação - Bruno Elias dos Santos Costa - 2013.pdf: 2053959 bytes, checksum: 6af8dff43a9a4b548490b5b15b557b8a (MD5) / Made available in DSpace on 2015-01-30T14:45:37Z (GMT). No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Dissertação - Bruno Elias dos Santos Costa - 2013.pdf: 2053959 bytes, checksum: 6af8dff43a9a4b548490b5b15b557b8a (MD5) Previous issue date: 2013-07-29 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / In this study, a highly sensitive and selective procedure for determination of arsenate and total arsenic in rice by electrothermal atomic absorption spectrometry after cloud point extraction As(V)-CPE-GF AAS was developed. The procedure is based on complex formation of As (V) ions with molybdate in the presence of 50.0 mmol L-1 sulfuric acid and 0.1 mmol L-1 ascorbic acid. The complex of As (V)-molybdate was extracted into the surfactant-rich phase of 0.06% w/v Triton X-114 solution. The variables affecting complex formation, extraction and phase separation such as complexing agent concentration, reducing agent concentration and electrolyte concentration were optimized using a factorial design and response surface methodology through central composite design (CCD). Under the optimal experimental conditions, the calibration graph was linear in the range of 0.03 – 10.0 μg L-1 for As (V) ions. The detection and quantification limits for As(V) were 0.0099 and 0.0331 μg L-1 respectively, obtaining an enrichment factor of 78.3 and the corresponding value for relative standard deviation (R.S.D) for 10 replicate determinations was below 5%. A two-level full factorial experimental design involving three factors (permanent modifiers, pyrolysis temperature PT and atomization temperature AT) was investigated to estimate the optimum values of the variables affecting the detection. It was demonstrated that iridium modifier and PT x AT interaction were considered in modeling the response surface. Recovery values were obtained between 90.8% and 113.1% for spiked samples. The method was successfully applied to the determination of As (V) and total arsenic in some rice samples. / Neste estudo, foi desenvolvido um procedimento altamente sensível e seletivo para determinação de As(V) e arsênio total em amostras de arroz por espectrometria de absorção atômica em forno de grafite após extração por ponto nuvem As(V)-CPE-GF AAS. O procedimento é baseado na formação do complexo de íons As(V) com molibdato na presença de 50,0 mmol L-1 de ácido sulfúrico e 0,1 mmol L-1 de ácido ascórbico. O complexo As(V)-molibdato foi extraído para fase rica em surfactante da solução de 0,06 % m/v de Triton X-114. As variáveis que afetam a formação do complexo, extração e a separação de fases, tais como a concentração do agente complexante, concentração do agente redutor e a concentração do eletrólito foram otimizadas utilizando planejamento fatorial e metodologia de superfície de resposta por meio do planejamento composto central (CCD). Sobre as condições otimizadas, a curva de calibração foi linear na faixa de 0,03 – 10,0 μg L-1 para íons As(V). Os limites de detecção e quantificação alcançados para As(V) foram 0,0099 e 0,0331 μg L-1 respectivamente, obtendo um fator de enriquecimento de 78,3 e o valor correspondente ao desvio padrão relativo (D.P.R.) para 10 replicatas foram abaixo de 5%. Um planejamento experimental fatorial de dois níveis envolvendo três fatores (modificadores permanentes, temperatura de pirólise TP e temperatura de atomização TA) foi investigado para estimar os valores ótimos das variáveis que afetam a detecção. Foi demonstrado que o modificador permanente de irídio e a interação TPxTA foram considerados na modelagem da superfície de resposta. Valores de recuperação foram obtidos entre 90,85% à 113,10% para amostras fortificadas. O método foi aplicado satisfatoriamente para a determinação de As(V) e arsênio total em algumas amostras de arroz beneficiadas na região.
46

Proposta de método para determinação de Pt em sangue total visando o uso como biomarcador de exposição ambiental por veículos automotivos / A method for determination of Pt in whole blood in order to use as biomarker of environmental exposure by automotive vehicles.

Leandro Mota Santos 19 June 2015 (has links)
Reflexo de um modo de vida que exige locomoção rápida e com um mínimo de conforto, atualmente, nas grandes metrópoles, há um grande número de veículos em circulação que emitem gases poluentes (hidrocarbonetos, CO e óxidos de nitrogênio - NOx). Para minimizar a emissão desses gases, os carros atuais são dotados de conversores catalíticos, formados pelos metais do grupo da platina, com a finalidade de converter gases nocivos em gases menos agressivos ao ambiente e ao homem. Porém, esses elementos constituintes dos conversores catalíticos podem ser expelidos para o ambiente, na forma de materiais particulados em suspensão, por volatilização ou junto com os gases da combustão. Desta forma, esses elementos podem acumular-se nos mais diversos ambientes. A utilização de amostras biológicas, tal como sangue, na investigação e no controle à exposição de elementos nos seres humanos vem sendo praticada há muito tempo. Estudos com materiais biológicos apontam que as concentrações de metais do grupo da Platina estão na ordem de ng/kg. Tais níveis de concentração representam um grande desafio para a Química Analítica, pois são muito baixos para que se tenham resultados com boa precisão e exatidão nas análises, mesmo utilizando técnicas muito sensíveis. Como alternativa para contornar os problemas, nas determinações destas baixas concentrações, etapas prévias de pré-concentração, com posterior determinação, vem sendo propostas com sucesso. Nessa pesquisa, para a pré-concentração dos analito, extração em ponto nuvem foi empregada com determinação por espectrometria de absorção atômica por forno de grafite. O procedimento da extração em ponto nuvem consiste em derivatizar os analitos em espécies hidrofóbicas por meio de um agente complexante, e extrair por micelas formadas a partir de um surfactante não iônico, induzidas por mudança de temperatura. Essa extração se baseia no fenômeno que ocorre com a formação de agregados micelares, quais apresentam caráter hidrofóbico. Foram estudados diferentes ligantes, e o melhor resultado para a extração foi obtido empregando-se o APDC (pirrolidina ditiocarbamato de amônio). Os parâmetros da extração em ponto nuvem otimizados para o melhor ligante foram: pH=7; 3,0x10-2 mol L-1 de APDC; 0,5 % m v-1 de Triton X-114; 60ºC durante 10 min de banho, 10 min de centrifugação e 50 mg L-1 Cu(II) como modificador químico. O método apresentou fator de enriquecimento de 24 vezes, mas o LOD (0,24 µg L-1) ficou muito acima dos valores apresentados em amostras de indivíduos expostos e não expostos. Adições de 1, 5 e 10 µg L-1 foram realizadas para avaliar a exatidão do método e apresentaram recuperações média de 91%. / Reflecting a way of life that requires fast displacement with a minimum of comfort, currently in big cities, there are a large number of vehicles that produce a large amount of waste gases (hydrocarbons, CO and nitrogen oxides - NOx) to atmosphere. To minimize the emission of these gases, current cars are equipped with catalytic converter, made of platinum group metals, which has the purpose of converting the noxious gases into less harmful gases to environment and man. However, these constituents of the catalytic converter can be expelled to the environment in form of particulates in suspension, or by volatilization along with the combustion gases. Thus, these elements can accumulate. Biological samples such as blood, urine, hair, nail, have been used for a long time in studies and control of human exposition to elements. Studies of biological materials indicate that the concentrations of platinum group metals are the order of ng/kg. Such concentration levels means a huge challenge for analytical chemistry, as they are too low to provide the necessary results with good precision and accuracy in the analysis, even using very sensitive techniques. As an alternative to overcome the problems in the provisions of these low concentrations, preconcentration methods, with subsequent determination has been proposed successfully. Cloud point extraction (CPE) was proposed in this work for pre-concentration of the analytes. CPE procedure consists in derivatizing the analytes into hydrophobic species by a complexing agent and extracts them trapped inside micelles formed from a nonionic surfactant, induced by temperature change. The cloud point extraction is based on the phenomenon that occurs with the formation of these hydrophobics aggregates by those micelles. Dithizone, DBTC, DMG, DDTC and APDC ligands were studied. The optimized parameters of cloud point extraction were: pH=7; 3,0x10-2 mol L-1 APDC; 0,5% m v-1 Triton X-114; 60 ºC while 10 min of termal bath and 10 min of centrifugation time. A Cu (II) 50 mg L-1 solution was used as a chemical modifier. The method was evaluated after optimized cloud point extraction\'s parameters conditions. It showed enrichment factor of 24-fold, but the limit of detection (0.24 µg L-1) was higher than the values expected to samples of exposed and non exposed individuals. A recovery test was done and a satisfactory recovery result was provided, up to 91%.
47

Determinação direta de elementos potencialmente tóxicos em arroz por GF AAS: desenvolvimento de métodos e aplicações / Direct determination of potentially toxic elements in rice by GF AAS: methods development and applications

Daniel Menezes Silvestre 26 March 2013 (has links)
O arroz é um dos alimentos mais consumidos no mundo, caracterizando-se como a base da alimentação para mais da metade da população mundial. De acordo com a Organização Mundial da Saúde (WHO), a ingestão de alimentos contaminados é uma das principais vias de absorção de elementos potencialmente tóxicos pelo ser humano. Por esse motivo, órgãos de fiscalização têm estabelecidos limites máximos permitidos desse tipo de elemento nos alimentos. Nesse sentido, o desenvolvimento de métodos e aplicações visando à determinação de elementos com caráter tóxico, tais como o Al, As, Cd e Pb em alimentos é de suma importância. Nesse projeto, foram desenvolvidos métodos para determinações diretas de Al, As, Cd e Pb em arroz por espectrometria de absorção atômica com forno de grafite e amostragem direta de sólidos (SS-GF AAS) que tem se mostrado uma técnica promissora especialmente devido à sua elevada sensibilidade e detectabilidade, além de dispensar morosos processos de decomposição de amostra. A adequada otimização do programa de aquecimento aliado ao uso de modificadores químicos adequados possibilitou o uso de calibração aquosa. Parâmetros importantes como o tamanho de partícula, massa de amostra e segregação de analito foram investigados. Observou-se que partículas inferiores a 100 µm geravam resultados precisos. A massa mínima ideal de amostra de arroz a ser utilizada na análise foi em torno de 300 µg. A massa máxima recomendada foi 500 µg. Segregação de Al e Cd não foram observadas na amostra de arroz. A segunda parte do projeto envolveu a aplicação do método de análise desenvolvido em amostras de arroz comercializadas na cidade de São Paulo. Investigou-se também a influência dos processos de lavagem e cozimento dos grãos sobre a concentração de Al, As, Cd e Pb. Todas as 17 amostras de diversos tipos e marcas de arroz analisadas apresentaram concentrações de As, Cd e Pb abaixo dos limites estabelecidos por lei. Com relação ao Al, não há regulamentado o valor de limite máximo. As maiores concentrações desse elemento foram observadas nos grãos de arroz integral. O processo de lavagem removeu significativamente a concentração de Al e Pb na maioria das amostras, entretanto, o mesmo não foi observado para o Cd. O processo de cozimento diminuiu a concentração de Cd e Pb em parte das amostras, e um pequeno aumento na concentração do Al foi observado, o qual pode ser atribuído à contaminação pelo ambiente. O cozimento do arroz em frascos de vidro ou panelas a base de alumínio não alterou a concentração desse elemento no arroz, nem mesmo quando a panela de alumínio foi polida com palha de aço / Rice is a staple food for more than 40% of the world\'s population. Considering that the main reason of contamination by potentially toxic element occurs by food ingestion, World Health Organization (WHO) has been controlling the levels of some contaminants. In this context, development of methods and applications associated to determination of potentially toxic elements such as Al, As, Cd and Pb in food are important. In this work, methods for direct determination of Al, As, Cd and Pb in rice by solid sampling graphite furnace atomic absorption spectrometry (SS-GF AAS) were developed. Solid sampling-GF AAS has shown as a promising technique especially due to its high sensitivity and detectability and the possibility to practice direct analysis of solid samples, dismissing tedious and error prone sample preparation step. The adequate heating program optimization associated to the use of chemical modifier allowed direct rice analysis against aqueous calibration. The influence of some parameters, such as particle size, sample mass size and analyte segregation on the analytical results were investigated. Results showed that particle size smaller than 100 µm generated accurate results. The minimum sample mass size recommended for analysis was around 300 µg and the maximum sample mass size was around 500 µg. Segregation of Cd and Al was not observed in the rice sample. The second part of the work involved the analysis of 17 rice samples commercially available in São Paulo city. Influence of rice washing and cooking procedure on the Al, As, Cd and Pb concentrations was also investigated. Concentration of all analytes were lower than the maximum allowed by WHO in all samples. The highest concentrations of Al were found in coarse rice. The washing process reduced significantly the concentrations of Al and Pb in most samples, however, the same was not observed for Cd. Cooking process reduced the concentration of Cd and Pb for most samples, probably by volatilization. On the other hand, an increase in Al concentration was observed. This fact could be attributed to the sample contamination during cooking process. Rice cooked in glass or aluminum container presented the same concentration of Al, even when polished aluminum container was used. These results indicated that there is no translocation of Al from container to food
48

Determinação de chumbo em açúcar por espectrometria de absorção atômica em forno de grafite tratado com tugstênio e ródio / Determination of lead in sugar by graphite furnace atomic absorption spectrometry (GFAAS) treated with tungsten-rhodium

Souza, Paulino Florêncio de 18 January 2005 (has links)
Um método de baixo custo é proposto para determinação direta de chumbo em açúcar por espectrometria de absorção atômica com forno de grafite e correção de fundo com fonte de deutério, empregando modificação química permanente com 250µg W + 200µg Rh e co-injeção de 5µg Rh. Os experimentos foram realizados com plataforma integrada ou ao no tubo de grafite com aquecimento longitudinal. Para avaliação da modificação química permanente, foram feitos experimentos na ausência de modificação e na presença de modificação química convencional com Pd+Mg. No decorrer do trabalho observou-se ser imprescindível a co-injeção de Rh para a estabilização térmica de chumbo na presença de açúcar. A amostra (8 g) é dissolvida em 100 ml de solução aquosa 0,2% v/v HNO3, e uma alíquota de 10 l é injetada com 5µl de solução de Rh na plataforma do tubo de grafite modelo Universal da Varian tratada com W e Rh. A massa característica (mo) e o limite de detecção do método foram 11 pg Pb e 5 ng g-1 respectivamente, e a vida útil do tubo de grafite foi de 860 queimas. O método apresentou boa reprodutibilidade com coeficiente de variação inferior a 2,5 % (n=3). As características analíticas foram comparadas com os métodos recomendados na literatura. A exatidão do método proposto para determinação direta de chumbo em açúcar foi avaliada pela comparação com método convencional utilizando Pd+Mg e nenhuma diferença estatística foi observada aplicando-se o teste t de Student ao nível de 95% de probabilidade, em amostras que receberam adição de chumbo / A simple method for the direct determination of lead in sugar by graphite furnace atomic absorption spectrometry (GFAAS) with platform treated with 250µg W + 200µg Rh and deuterium background correction is proposed. Samples (8 g) were dissolved in 100 ml of an aqueous solution containing 0,2% v/v HNO3 and 10µl aliquots were co-injected with 5µg Rh into the integrated platform modified with W-Rh of the Universal Varian longitudinal heated graphite atomizer. The characteristic mass (mo) and the method detection limit were 11 pg Pb and 5,0 ng g-1 Pb, respectively, and the tube life time was 860 firings. The relative standard deviation of measurements (n=3) was lower than 2,5 %. For the evaluation of the permanent chemical modifier, parallel experiments were carried in the presence of diluted nitric acid and with the conventional Pd+Mg chemical modifier. Experiments were made either with manual inserted graphite plataforms or integrated plataforms into longitudinal graphite tubes. Comparison of the proposed method with a method based on Pd+Mg chemical modifier showed no statistical differences by applying a t-test at 95% confidence level, for sugar sample solution spiked with lead
49

Determinação de chumbo em açúcar por espectrometria de absorção atômica em forno de grafite tratado com tugstênio e ródio / Determination of lead in sugar by graphite furnace atomic absorption spectrometry (GFAAS) treated with tungsten-rhodium

Paulino Florêncio de Souza 18 January 2005 (has links)
Um método de baixo custo é proposto para determinação direta de chumbo em açúcar por espectrometria de absorção atômica com forno de grafite e correção de fundo com fonte de deutério, empregando modificação química permanente com 250µg W + 200µg Rh e co-injeção de 5µg Rh. Os experimentos foram realizados com plataforma integrada ou ao no tubo de grafite com aquecimento longitudinal. Para avaliação da modificação química permanente, foram feitos experimentos na ausência de modificação e na presença de modificação química convencional com Pd+Mg. No decorrer do trabalho observou-se ser imprescindível a co-injeção de Rh para a estabilização térmica de chumbo na presença de açúcar. A amostra (8 g) é dissolvida em 100 ml de solução aquosa 0,2% v/v HNO3, e uma alíquota de 10 l é injetada com 5µl de solução de Rh na plataforma do tubo de grafite modelo Universal da Varian tratada com W e Rh. A massa característica (mo) e o limite de detecção do método foram 11 pg Pb e 5 ng g-1 respectivamente, e a vida útil do tubo de grafite foi de 860 queimas. O método apresentou boa reprodutibilidade com coeficiente de variação inferior a 2,5 % (n=3). As características analíticas foram comparadas com os métodos recomendados na literatura. A exatidão do método proposto para determinação direta de chumbo em açúcar foi avaliada pela comparação com método convencional utilizando Pd+Mg e nenhuma diferença estatística foi observada aplicando-se o teste t de Student ao nível de 95% de probabilidade, em amostras que receberam adição de chumbo / A simple method for the direct determination of lead in sugar by graphite furnace atomic absorption spectrometry (GFAAS) with platform treated with 250µg W + 200µg Rh and deuterium background correction is proposed. Samples (8 g) were dissolved in 100 ml of an aqueous solution containing 0,2% v/v HNO3 and 10µl aliquots were co-injected with 5µg Rh into the integrated platform modified with W-Rh of the Universal Varian longitudinal heated graphite atomizer. The characteristic mass (mo) and the method detection limit were 11 pg Pb and 5,0 ng g-1 Pb, respectively, and the tube life time was 860 firings. The relative standard deviation of measurements (n=3) was lower than 2,5 %. For the evaluation of the permanent chemical modifier, parallel experiments were carried in the presence of diluted nitric acid and with the conventional Pd+Mg chemical modifier. Experiments were made either with manual inserted graphite plataforms or integrated plataforms into longitudinal graphite tubes. Comparison of the proposed method with a method based on Pd+Mg chemical modifier showed no statistical differences by applying a t-test at 95% confidence level, for sugar sample solution spiked with lead
50

Vinhos brasileiros : teores totais e bioacessibilidade de As, Cd, Cu e Pb, teores de polifenóis totais e avaliação da rotulagem / Brazilian wine : total contents and bioaccessibility of As, Cd, Cu and Pb, total polyphenols contents and labeling assessement

Mazon, Elaine Marra de Azevedo 21 August 2018 (has links)
Orientador: Marcelo Alexandre Prado / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Alimentos / Made available in DSpace on 2018-08-21T19:36:01Z (GMT). No. of bitstreams: 1 Mazon_ElaineMarradeAzevedo_D.pdf: 2626954 bytes, checksum: 7cc1b7c8e92de797976754431156c2af (MD5) Previous issue date: 2013 / Resumo: O consumo de vinhos no Brasil aumentou cerca de 20% na última década, e sua comercialização vem se difundindo, principalmente, pelo aumento da oferta, aumento do poder aquisitivo da população brasileira, aumento da produção e pelos benefícios à saúde que lhe são atribuídos. A análise de elementos traço nos vinhos é de grande importância para o controle da qualidade, autenticidade, biodisponibilidade de metais e estudo da toxicidade, visando garantir a segurança alimentar para os consumidores. Este trabalho descreve o desenvolvimento de um método empregando a espectrometria de absorção atômica com forno de grafite para a determinação de arsênio (As), cádmio (Cd), cobre (Cu) e chumbo (Pb) em amostras de vinhos brasileiros. A digestão ácida preliminar não foi necessária no preparo de amostra. O programa de aquecimento, empregado no forno de grafite foi otimizado para os diferentes tipos de vinhos e as amostras foram diluídas na proporção de 1:3 com ácido nítrico (65% v/v) e peróxido de hidrogênio (30% m/m). A curva analítica foi preparada em meio aquoso e alguns modificadores foram investigados para cada elemento. As determinações foram realizadas nas seguintes faixas lineares 10-100 µg L-1 Cu; 5,0 - 60 µg L-1 Pb; 0,5 - 2,0 µg L-1 Cd; 10 - 60 µg L-1 As. Os limites de quantificação obtidos foram 11,5; 2,5; 0,22 e 5,0 µg L-1, respectivamente. As recuperações obtidas variaram de 92-103% (vinho tinto) e 99-106% (vinho branco) para o Cu, 97-107% (vinho tinto) e 95-101% (vinho branco) para o Pb, 89-102% (vinho tinto) e 98-106% (vinho branco) para o Cd, e 103-106% (vinho tinto) e 99-107% (vinho branco) para o As. Foram analisadas 45 amostras de vinhos nacionais adquiridos no comércio de Campinas/SP de diversas regiões do Brasil. Foram determinados os teores de As, Cd, Cu e Pb nas amostras de vinho e os valores encontrados estavam abaixo dos teores estabelecidos pela legislação brasileira. Foram calculadas as contribuições dos vinhos estudados na dieta de um adulto, com relação a ingesta destes elementos e os valores demonstraram que os vinhos estudados apresentaram baixa contribuição. Também foram determinados os valores de pH e os teores de polifenóis totais nos vinhos, as amostras apresentaram valores compatíveis com os relatados na literatura com valores médios para polifenóis em vinhos de mesa de 2046,0 mg L-1, vinhos tinto 1443,0 mg L-1 e espumantes 1606,0 mg L-1. Os valores de pH variaram de 2,8 a 3,8 entre os vinhos. Foi feito o estudo da acessibilidade e da fração dialisável pelo método in vitro dos elementos As, Cd, Cu e Pb nos vinhos e os resultados demonstraram para todos os elementos que a fração solúvel foi maior que 37% e a dialisável, maior que 43%, indicando alta capacidade de acessibilidade. Quanto aos dizeres de rotulagem foi observada uma necessidade de complementação da atual legislação específica para vinhos, com a finalidade de melhorar a qualidade das informações oferecidas ao consumidor através dos rótulos dos vinhos / Abstract: Wine consumption in Brazil has been increasing in 20% in the last decade, and its sales have been disseminating mainly due to offer and production increase, and to health benefits attributed to it. The analysis of trace elements in wine is of great importance for quality control, authenticity, metal bioavailability and toxicity study, aiming at granting safety to consumers. This paper describes the development of a method which employs atomic absorption spectrometry with graphite oven in order to determine arsenic, cadmium, copper and lead in Brazilian wines samples. A preliminary acid digestion has not been necessary in the sample preparation. The heating program employed to the graphite oven has been optimized for the different types of wine and the samples have been diluted in proportion of 1:3 with nitric acid (65% v/v) and hydrogen peroxide (30% m/m). The analytical curve has been prepared in aqueous medium and some modifiers have been investigated for each element. The determinations have been performed in the following linear ranges 10-100 µg L-1 Cu; 5,0 - 60 µg L-1 Pb; 0,5 - 2,0 µg L-1 Cd; 10 - 60 µg L-1 As. The qualification limits obtained were 11,5; 2,5; 0,22 e 5,0 µg L-1, respectively. The recoveries obtained ranged from 92-103% (red wine) and 99-106% (white wine) for Cu, 97-107% (red wine) and 95-101% (white wine) for Pb, 89-102% (red wine) and 98-106% (white wine) for Cd, and 103-106% (red wine) and 99-107% (white wine) for As. Brazilian wines, about 45 samples from Campinas/SP local market have been analyzed at several Brazilian regions. The contents of As, Cd, Cu and Pb have been determined in the samples and the amounts found out were below the contents established by the Brazilian legislation. The contribution of those elements on the diet of an adult have been calculated, and the amounts have shown that the studied wines presented low contribution. The pH levels and the total polyphenols contents have also been determined, the samples presented compatible rates according to the literature, with average rates for polyphenol in table wines at 2046,0 mg L-1, red wines 1443,0 mg L-1 and sparking 1606,0 mg L-1. The pH rates varied from 2,8 to 3,8 among the wines. The accessibility and the dialysis fraction through the in vitro method have also been studied for the elements As, Cd, Cu and Pb in the wines. The results show that for all elements soluble fractions greater than 37% and higher than 43% dialyzable indicating high capacity accessibility. As for labeling was observed a need complement the current legislation for wine in order to improve the quality of information offered to consumers through wine labels / Doutorado / Ciência de Alimentos / Doutora em Ciência de Alimentos

Page generated in 0.043 seconds