• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 41
  • 2
  • 1
  • Tagged with
  • 44
  • 44
  • 39
  • 34
  • 29
  • 21
  • 19
  • 18
  • 18
  • 8
  • 7
  • 7
  • 7
  • 7
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Desenvolvimento e validação de métodos analíticos para determinação simultânea de fármacos que atuam no controle da hipertensão arterial / Development and validation of analytical methods for simultaneous determination of drugs that act on the control of hypertension.

Oliveira, Claudia Vilela de 13 April 2015 (has links)
A hipertensão arterial é um fator de risco de alta prevalência para as doenças cardiovasculares, principalmente no mundo industrializado, aumentando o problema de saúde em virtude do aumento da longevidade e da prevalência de fatores contribuintes como obesidade, sedentarismo e dietas inadequadas. Estima-se que 10% das 55 milhões de mortes que acontecem a cada ano, são consequências da hipertensão arterial. Dois terços desses eventos ocorrem nos países em desenvolvimento, incluindo o Brasil, afetando principalmente a população de menor nível socioeconômico. Diuréticos como hidroclorotiazida associados a betabloqueadores como o metoprolol são exemplos de fármacos utilizados no controle da hipertensão. O presente trabalho teve como objetivo desenvolver, validar e comparar métodos analíticos para a identificação e quantificação simultânea do tartarato de metoprolol e da hidroclorotiazida por eletroforese capilar (CE) e por cromatografia líquida de ultra eficiência (UHPLC). Para a definição das melhores condições de análise e determinação simultânea dos analitos em estudo, e otimização do método, utilizou-se metodologia de superfície de resposta (ou Response Surface Methodology - RSM). O método por CE utilizou um capilar de sílica fundida com comprimento total de 30,2 cm x 50 &#181;m d.i. O tampão utilizado foi tetraborato de sódio 25,0 mmol L-1, injeção hidrodinâmica 0,5 psi/6s, tensão aplicada +15 kV, detecção em 225 nm temperatura a 25ºC. O tartarato de metoprolol e hidroclorotiazida foram separados em 1,2 e 2,1 min, respectivamente .O método por UHPLC foi realizado empregando uma coluna ZORBAX® SB C18 (50 mm x 2,1 mm x 1,8 &#181;m), fase móvel constituída por água:acetornitrila:trietilamina (83:17:0,2 v/v/v), pH 3 ajustado com ácido fosfórico, utilizou vazão de 0,9 mL min-1. A hidroclorotiazida e o tartarato de metoprolol foram separados em 0,7 e 1,0 min, respectivamente. Os métodos analíticos foram validados de acordo com os requerimentos da ANVISA, ICH e Farmacopéia Americana. Os métodos apresentaram boa linearidade com coeficiente de correlação maiores que 0.99, a precisão intra- e inter-day para os tempos de migração foi apropriada (DPR < 2%), a exatidão do método foi comprovada mediante teste de recuperação, obtendo-se valores de 100±2. Portanto, os métodos propostos demonstraram ser lineares, precisos, exatos e rápidos para quantificação simultânea da hidroclorotiazida e do tartarato de metoprolol. E podem ser considerados confiáveis para serem empregados em análise de rotina para controle de qualidade destes produtos farmacêuticos. / Hypertension is a risk factor of high prevalence for cardiovascular diseases, especially in the industrialized world, increasing health problems as a result of increased longevity and the prevalence of contributing factors such as obesity, physical inactivity and inadequate diets. It is estimated that 10% of 55 million deaths that occur each year, are consequences of hypertension. Two-thirds of those events occur in developing countries, including Brazil, affecting mainly the population from lower socioeconomic backgrounds. Diuretics like hydrochlorothiazide associated with beta-blockers such as metoprolol tartrate are examples of drugs used in the control of hypertension. The present work had as objective to develop, validate and compare analytical methods for identification and simultaneous quantification of metoprolol tartrate and hydrochlorothiazide by capillary electrophoresis (CE) and ultra performance liquid chromatography (UHPLC). For the definition of the best conditions of analysis and simultaneous determination of drugs in study, and optimization of the method, it was used response surface methodology (RSM or \"Response Surface Methodology). The CE method used a fused silica capillary with total length of 30.2 cm x 50 &#181;m d.i. The electrolyte used was sodium tetraborate 25,0 mmol L-1, hydrodynamic injection 0.5 psi/6s, applied voltage +15 kV, detection in 225 nm temperature at 25ºC. The metoprolol tartrate and hydrochlorothiazide were separated into 1.2 and 2.1 min, respectively. The UHPLC method was carried out employing a ZORBAX SB® C18 (50 mm x 2.1 mm x 1.8 &#181;m) column, mobile phase consisting of water: acetornitrila: triethylamine (83: 17: 0.2 v/v/v), 3 pH adjusted with phosphoric acid, the flow was 0.9 mL min-1. Hydrochlorothiazide and metoprolol tartrate were separated in 0.7 and 1.0 min, respectively. The analytical methods have been validated in accordance with the requirements of ANVISA, ICH and American Pharmacopoeia. The methods showed good linearity with correlation coefficient greater than 0.99, precision inter and intra day for times of migration was appropriate (DPR < 2%), the accuracy of the method has been proven by recovery test, obtaining values of 100 ± 2. Therefore, the proposed methods have shown to be linear, precise, accurate and fast for simultaneous quantification of hydrochlorothiazide and metoprolol tartrate; and can be considered reliable to be used in routine analysis for quality control of pharmaceutical products.
22

Desenvolvimento de métodos analíticos para a identificação de drogas facilitadoras de crime em amostras de urina / Developing analytical methods for identification of drug-facilitated crime in urine samples

Bairros, André Valle de 12 December 2014 (has links)
As drogas facilitadoras de crime (DFC) são uma série de substâncias químicas que permitem o ato sexual e/ou roubo com pouca ou nenhuma resistência da vítima. Benzodiazepínicos, gama-hidroxibutirato (GHB), cetamina e etanol são clássicas DFC, porém outras substâncias também têm sido utilizadas. Devido às diferentes classes de DFC e a necessidade de métodos sensíveis, a determinação dessas substâncias é um desafio aos toxicologistas forenses. A proposta do estudo foi desenvolver métodos analíticos para determinação principais analitos alvos de DFC para benzodiazepínicos, cetamina e GHB em amostras de urina. Esta matriz biológica é considerada uma amostra não-invasiva e apresenta um período de detecção maior que o sangue. A preparação das amostras foi avaliada através de microextração em fase líquida (LPME) e extração líquido-líquido (LLE). A LPME é uma técnica de extração de drogas que utiliza menor quantidade de solventes orgânicos, maior praticidade e possibilidade de obtenção de altos valores de recuperação. Os analitos foram determinados por cromatografia gasosa acoplada à espectrometria de massas (GC-MS). A LPME validada para benzodiazepínicos e seus produtos de biotransformação exigiu uma combinação de solventes e dupla derivatização para atingir a sensibilidade exigida, enquanto o método para determinação de cetamina, norcetamina e deidronorcetamina utilizou óleo essencial de eucalipto como meio extrator, caracterizando-se um procedimento ecologicamente correto com alta sensibilidade. A extração de GHB foi efetiva por LLE com redução da quantidade de solvente e tempo de análise sem o prejuízo na sensibilidade. Em geral, os métodos desenvolvidos neste trabalho são sensíveis e confiáveis para todos os analitos relatados e conclui-se que a LPME é uma técnica de preparo de amostra eficiente, versátil de baixo custo. Estas condições permitem que sua implementação em qualquer laboratório de análises toxicológicas, podendo ser aplicada em situações de DFC ou de qualquer outra natureza. / Drug-facilitated crime (DFC) are a series of chemicals that allow the sexual act and/or theft with little or no resistance from the victim. Benzodiazepines, gamma-hydroxybutyrate (GHB) and ketamine and ethanol are considered classic DFC, however other substances were also used as the DFC. Due to the different classes of DFC and the need for sensitive methods, the determination of these substances is a challenge to forensic toxicologists. The purpose of this study was to develop analytical methods for determination of the main target analytes of DFC for benzodiazepines, ketamine and GHB in urine samples. This biological matrix is considered a non-invasive sample and shows a larger window of detection than blood. Sample preparation was assessed using liquid phase microextraction (LPME) and liquid-liquid extraction (LLE). The LPME is a drug extraction technique that uses less organic solvents, greater practicality and possibility of obtaining high recovery values. The analytes were determined by gas chromatography - mass spectrometry (GC-MS). The validated LPME technique for benzodiazepines and their metabolites required a combination of solvents and double derivatization to achieve the required sensitivity, while the ketamine, norketamine and dehydronorketamine method used essential oil of eucalyptus as solvent, characterizing a green chemistry approach with high sensitivity. The extraction of GHB was effective by LLE with a reduced amount of solvent and the analysis time without loss in sensitivity. In general, the methods developed in this work using GC-MS are sensitive and reliable for all analytes reported and LPME technique showed to be an efficient sample preparation, versatile and low cost. These conditions allow LPME implementation in any laboratory of toxicological analysis and it can be applied in situations of DFC or any other kind of analysis.
23

Reator anaeróbio-aeróbio de leito fixo, com recirculação da fase líquida, aplicado ao tratamento de esgoto sanitário / Anaerobic-aerobic fixed bed reactor, with recycle of the liquid phase, applied to the treatment of domestic sewage

Oliveira Netto, Antonio Pedro de 28 March 2007 (has links)
Este trabalho avaliou o desempenho de um sistema que combina os processos anaeróbio e aeróbio, para tratamento de esgoto sanitário, operado de modo contínuo sem e com recirculação da fase líquida. A combinação dos processos anaeróbio e aeróbio tem como objetivo aproveitar as vantagens de cada um, minimizando seus aspectos negativos. Foi utilizado um reator, em escala de bancada, de leito fixo e fluxo contínuo de escoamento ascendente com argila expandida e espuma de poliuretano como suportes de imobilização da biomassa. O desempenho do sistema foi avaliado em três diferentes tempos de detenção hidráulica (TDH), 6, 8 e 10 horas, na fase anaeróbia, nos quais os melhores valores de remoção de matéria orgânica chegaram a 80%, com valores de DQO efluente abaixo de 150 mg/L. Com a inserção da fase aeróbia ao sistema (TDH de aproximadamente 11 horas, sendo 8 horas para a fase anaeróbia e 3 horas para a fase aeróbia), a eficiência subiu para mais de 90% com DQO efluente abaixo dos 50 mg/L. A nitrificação ocorreu perto do 15° dia operacional do sistema combinado e estava praticamente estável ao fim dessa etapa operacional. Após o 20º dia de operação as concentrações de nitrito mantiveram-se sempre baixas, o que indica equilíbrio da nitrificação. Foram obtidos ganhos quando feita recirculação do efluente tratado, principalmente em relação à remoção de matéria orgânica (95%) e remoção de nitrogênio total que foi de 75% para razão de recirculação de 1,5. O reator avaliado apresentou estabilidade operacional, alta remoção de matéria orgânica e nitrogênio sem a necessidade de adição de fonte exógena de carbono e de suplementação de alcalinidade. / This work evaluated the performance of a system that combines anaerobic and aerobic processes, for treatment of domestic sewage. The bench-scale fixed-film reactor was operated in a continuous way without and with recycle of the liquid phase. Expanded clay and polyurethane foam were used as supports for immobilization of the biomass. Initially, the system was operated under anaerobic condition and its performance was evaluated for three different hydraulic retention times (HRT), 6, 8 and 10 h. In this phase, COD removal efficiency of 80% was reached for HRT of 10 h, with effluent COD below 150 mgCOD/L. The combined anaerobic-aerobic operation (HRT of approximately 11 h, being 8 h for the anaerobic phase and 3 h for the aerobic phase) favored the organic matter removal that reached 90%, with effluent COD below 50 mgCOD/L. The operation with liquid recycle provided the best results with COD removal of 95% and total nitrogen removal of 75% under recycle ratio of 1.5. The anaerobic-aerobic fixed bed reactor, with recycle of the liquid phase, proved to be an excellent alternative for domestic sewage treatment, mainly when organic matter and nitrogen removals are required. The concomitant C and N removal without addition of exogenous source electron donor and with no additional alkalinity supplementation was the main advantage of this reactor over the conventional reactors applied for this purpose.
24

Reator anaeróbio-aeróbio de leito fixo em escala piloto, com recirculação da fase líquida, aplicado ao tratamento de esgoto sanitário / Anaerobic-aerobic pilot-scale fixed-bed reactor, with recycle of the liquid phase, applied to the treatment of domestic sewage

Oliveira Netto, Antonio Pedro de 29 April 2011 (has links)
Este trabalho fundamentou-se na concepção, desenvolvimento tecnológico, ampliação de escala e avaliação do comportamento de sistema combinado anaeróbio-aeróbio de leito fixo e fluxo ascendente, com recirculação da fase líquida, para tratamento de esgoto sanitário. O reator, em escala piloto, foi construído em formato cilíndrico e confeccionado em fibra de vidro com volume total de aproximadamente 2,5 \'M POT.3\', com intuito de desenvolver um sistema capaz de operar como única unidade de tratamento para remoção de matéria orgânica e nitrogênio, reduzindo a geração de lodo e o consumo de energia pela combinação dos processos anaeróbio e aeróbio, possibilitando o aproveitamento das vantagens de cada um e minimizando seus aspectos negativos. Os melhores resultados operacionais foram encontrados para a etapa com tempo de detenção hidráulica total (TDH) de 12 horas e razão de recirculação (r) igual a 3,0, apresentando eficiências médias de remoção de DQO, \'N\'-NTK e SST de 92 ± 3%; 68 ± 11% e 75 ± 7%, respectivamente, com valores médios efluentes de 54 ± 22 mgDQO/L, 14 ± 10 mg \'N\'-NTK/L e 70 ± 42 mgSST/L. Os valores médios de carga orgânica volumétrica (COV) e carga volumétrica de nitrogênio (CVN) removidas foram de 1,08 ± 0,04 kgDQO/\'M POT.3\'.dia e 0,06 ± 0,02 kgNTK/\'M POT.3\'.dia para esta etapa. A estabilidade operacional durante a etapa com TDH de 12 h, a alta remoção de matéria orgânica e nitrogênio, sem a necessidade de adição de fonte exógena de carbono, para promover o processo de desnitrificação, e de suplementação de alcalinidade consumida durante a nitrificação, e a reduzida necessidade de manutenção devido à tecnologia de fabricação adotada, comprovam a viabilidade técnica de utilização do reator combinado de leito fixo como unidade compacta para pequenas comunidades ou vazões afluentes, para tratamento de esgoto sanitário. / This work was based on design, technology development, scale up and performance evaluation of an up-flow combined anaerobic-aerobic fixed bed system, with recycle of the liquid phase, for treatment of domestic sewage. The pilot scale reactor was built in a fiberglass cylindrical shape with a total volume of approximately 2.5 \'M POT.3\', aiming at the development of a system capable of operate as a single treatment unit for organic matter and nitrogen removal, with low sludge production and energy consumption by the advantages of combination of anaerobic and aerobic processes. The improved operating results were found for the condition with overall hydraulic retention time (HRT) of 12 hours and recycle ratio (r) equal to 3.0, with average removal efficiencies of COD, TKN and TSS of 92 ± 3%, 68 ± 11% and 75 ± 7%, respectively, with average effluent values of 54 ± 22 mgCOD/L, 14 ± 10 mgTKN/L and 70 ± 42 mgTSS/L. The average values of removed organic loading rate (OLR) and nitrogen volumetric loading (NVL) reached 1.06 ± 0.04 kgCOD/\'M POT.3.d and 0.06 ± 0.02 kgTKN/\'\'M POT.3\'.d for this phase. The operational stability during the stage with HRT of 12 h, the high organic matter and nitrogen removal, without addition of exogenous carbon source (electron donor) to promote the denitrification process, with no supplementation of alkalinity consumed during nitrification, and the reduced maintenance due to manufacturing technology adopted, proved the technical feasibility of the combined fixed-bed reactor as a compact unit for small communities or low inflow rates, for treatment of domestic sewage.
25

Reator anaeróbio-aeróbio de leito fixo, com recirculação da fase líquida, aplicado ao tratamento de esgoto sanitário / Anaerobic-aerobic fixed bed reactor, with recycle of the liquid phase, applied to the treatment of domestic sewage

Antonio Pedro de Oliveira Netto 28 March 2007 (has links)
Este trabalho avaliou o desempenho de um sistema que combina os processos anaeróbio e aeróbio, para tratamento de esgoto sanitário, operado de modo contínuo sem e com recirculação da fase líquida. A combinação dos processos anaeróbio e aeróbio tem como objetivo aproveitar as vantagens de cada um, minimizando seus aspectos negativos. Foi utilizado um reator, em escala de bancada, de leito fixo e fluxo contínuo de escoamento ascendente com argila expandida e espuma de poliuretano como suportes de imobilização da biomassa. O desempenho do sistema foi avaliado em três diferentes tempos de detenção hidráulica (TDH), 6, 8 e 10 horas, na fase anaeróbia, nos quais os melhores valores de remoção de matéria orgânica chegaram a 80%, com valores de DQO efluente abaixo de 150 mg/L. Com a inserção da fase aeróbia ao sistema (TDH de aproximadamente 11 horas, sendo 8 horas para a fase anaeróbia e 3 horas para a fase aeróbia), a eficiência subiu para mais de 90% com DQO efluente abaixo dos 50 mg/L. A nitrificação ocorreu perto do 15° dia operacional do sistema combinado e estava praticamente estável ao fim dessa etapa operacional. Após o 20º dia de operação as concentrações de nitrito mantiveram-se sempre baixas, o que indica equilíbrio da nitrificação. Foram obtidos ganhos quando feita recirculação do efluente tratado, principalmente em relação à remoção de matéria orgânica (95%) e remoção de nitrogênio total que foi de 75% para razão de recirculação de 1,5. O reator avaliado apresentou estabilidade operacional, alta remoção de matéria orgânica e nitrogênio sem a necessidade de adição de fonte exógena de carbono e de suplementação de alcalinidade. / This work evaluated the performance of a system that combines anaerobic and aerobic processes, for treatment of domestic sewage. The bench-scale fixed-film reactor was operated in a continuous way without and with recycle of the liquid phase. Expanded clay and polyurethane foam were used as supports for immobilization of the biomass. Initially, the system was operated under anaerobic condition and its performance was evaluated for three different hydraulic retention times (HRT), 6, 8 and 10 h. In this phase, COD removal efficiency of 80% was reached for HRT of 10 h, with effluent COD below 150 mgCOD/L. The combined anaerobic-aerobic operation (HRT of approximately 11 h, being 8 h for the anaerobic phase and 3 h for the aerobic phase) favored the organic matter removal that reached 90%, with effluent COD below 50 mgCOD/L. The operation with liquid recycle provided the best results with COD removal of 95% and total nitrogen removal of 75% under recycle ratio of 1.5. The anaerobic-aerobic fixed bed reactor, with recycle of the liquid phase, proved to be an excellent alternative for domestic sewage treatment, mainly when organic matter and nitrogen removals are required. The concomitant C and N removal without addition of exogenous source electron donor and with no additional alkalinity supplementation was the main advantage of this reactor over the conventional reactors applied for this purpose.
26

Desenvolvimento de métodos analíticos para a identificação de drogas facilitadoras de crime em amostras de urina / Developing analytical methods for identification of drug-facilitated crime in urine samples

André Valle de Bairros 12 December 2014 (has links)
As drogas facilitadoras de crime (DFC) são uma série de substâncias químicas que permitem o ato sexual e/ou roubo com pouca ou nenhuma resistência da vítima. Benzodiazepínicos, gama-hidroxibutirato (GHB), cetamina e etanol são clássicas DFC, porém outras substâncias também têm sido utilizadas. Devido às diferentes classes de DFC e a necessidade de métodos sensíveis, a determinação dessas substâncias é um desafio aos toxicologistas forenses. A proposta do estudo foi desenvolver métodos analíticos para determinação principais analitos alvos de DFC para benzodiazepínicos, cetamina e GHB em amostras de urina. Esta matriz biológica é considerada uma amostra não-invasiva e apresenta um período de detecção maior que o sangue. A preparação das amostras foi avaliada através de microextração em fase líquida (LPME) e extração líquido-líquido (LLE). A LPME é uma técnica de extração de drogas que utiliza menor quantidade de solventes orgânicos, maior praticidade e possibilidade de obtenção de altos valores de recuperação. Os analitos foram determinados por cromatografia gasosa acoplada à espectrometria de massas (GC-MS). A LPME validada para benzodiazepínicos e seus produtos de biotransformação exigiu uma combinação de solventes e dupla derivatização para atingir a sensibilidade exigida, enquanto o método para determinação de cetamina, norcetamina e deidronorcetamina utilizou óleo essencial de eucalipto como meio extrator, caracterizando-se um procedimento ecologicamente correto com alta sensibilidade. A extração de GHB foi efetiva por LLE com redução da quantidade de solvente e tempo de análise sem o prejuízo na sensibilidade. Em geral, os métodos desenvolvidos neste trabalho são sensíveis e confiáveis para todos os analitos relatados e conclui-se que a LPME é uma técnica de preparo de amostra eficiente, versátil de baixo custo. Estas condições permitem que sua implementação em qualquer laboratório de análises toxicológicas, podendo ser aplicada em situações de DFC ou de qualquer outra natureza. / Drug-facilitated crime (DFC) are a series of chemicals that allow the sexual act and/or theft with little or no resistance from the victim. Benzodiazepines, gamma-hydroxybutyrate (GHB) and ketamine and ethanol are considered classic DFC, however other substances were also used as the DFC. Due to the different classes of DFC and the need for sensitive methods, the determination of these substances is a challenge to forensic toxicologists. The purpose of this study was to develop analytical methods for determination of the main target analytes of DFC for benzodiazepines, ketamine and GHB in urine samples. This biological matrix is considered a non-invasive sample and shows a larger window of detection than blood. Sample preparation was assessed using liquid phase microextraction (LPME) and liquid-liquid extraction (LLE). The LPME is a drug extraction technique that uses less organic solvents, greater practicality and possibility of obtaining high recovery values. The analytes were determined by gas chromatography - mass spectrometry (GC-MS). The validated LPME technique for benzodiazepines and their metabolites required a combination of solvents and double derivatization to achieve the required sensitivity, while the ketamine, norketamine and dehydronorketamine method used essential oil of eucalyptus as solvent, characterizing a green chemistry approach with high sensitivity. The extraction of GHB was effective by LLE with a reduced amount of solvent and the analysis time without loss in sensitivity. In general, the methods developed in this work using GC-MS are sensitive and reliable for all analytes reported and LPME technique showed to be an efficient sample preparation, versatile and low cost. These conditions allow LPME implementation in any laboratory of toxicological analysis and it can be applied in situations of DFC or any other kind of analysis.
27

Materiais com estrutura perovskita : síntese e aplicação na adsorção em fase líquida / Materials with perovskite structure : synthesis and application in liquid phase adsorption

Leite, Jamila Oliveira 28 September 2017 (has links)
Researchers are still making major efforts to obtain active, selective and high surface area. Perovskite-type catalysts have gained prominence in recent years, as they have properties that allow their wide use in various catalytic reactions and in the adsorption area, because their materials are easy to obtain and they have a low cost. Studies that enable the parameters identification that help to improve, in improving these potentialities, become paramount and of great value, mainly for the environmental application. In this regard, this paper was developed with the objective of obtaining oxides with perovskite structure based on nickel for later evaluation of its evaluation of the dye removal ability in solution. The adsorbent LaNiO3 was prepared by the collagen-modified protein method and the adsorbents LaNiO3/Al2O3 and LaNiO3 /TiO2 were prepared by impregnation with excess solvent. The samples were analyzed by TG / DTG, FTIR, XRD analyzed the samples by powder method, ASE and TPR. The TG/ DTG analysis allowed the identification of the best calcination temperature to obtain the perovskite. The FTIR results of the LNC350 sample showed bands attributed to the characteristic groups of the complexing agent, suggesting a possible coordination of the present metals. The X-ray diffractograms of the LNC900, LNC900/Al and LNC900/Ti samples proved the formation and maintenance of the crystalline phase of the perovskites in the presence of the alumina and titania supports. The supports promoted an increase in the total area in relation to the mass sample. The results of the TPR analysis were able to show the reduction zones, characteristic of LaNiO3 type materials. The kinetic and equilibrium adsorption studies enabled the evaluation of the adsorbate interaction on the surface of the adsorbent. / Grandes esforços estão sendo feitos por parte dos pesquisados para o desenvolvimento e obtenção de materiais cada vez mais ativos, estáveis e de baixo custo. Óxidos do tipo perovskita têm ganhado grande destaque nos últimos anos por apresentar propriedades que permitem seu uso em diversas reações catalíticas e na área de adsorção, principalmente, porque trata-se de materiais versáteis e de fácil obtenção. Estudos que viabilizem a identificação de parâmetros que auxiliam no melhoramento dessas potencialidades são de grande valia, sobretudo, na aplicação ambiental. Nesse sentido, esse trabalho foi desenvolvido com o objetivo de obter óxidos com estrutura perovskita a base de níquel e avaliação da capacidade destes na remoção de corantes em solução. O adsorvente LaNiO3 foi preparado através do método proteico modificado com colágeno e os adsorventes LaNiO3/Al2O3 e LaNiO3/TiO2 foram preparados através da impregnação por excesso de solvente. As amostras foram analisadas por TG/DTG, FTIR, DRX pelo método de pó, ASE e RTP. As análises de TG/DTG possibilitaram a identificação da melhor temperatura de calcinação para a obtenção da perovskita. O resultado de FTIR da amostra LNC350 mostrou as bandas atribuídas aos grupos característicos do agente complexante, sugerindo uma possível coordenação dos metais presentes. Os difratogramas de raios X das amostras LNC900, LNC900/Al e LNC900/Ti confirmaram a formação e a manutenção da fase cristalina das perovskitas na presença dos suportes alumina e titânia. Os suportes promoveram um aumento na área total em relação a amostra mássica. Os resultados das análises de RTP puderam mostrar as zonas de redução, característicos dos materiais do tipo LaNiO3. Os estudos cinéticos e de equilíbrio de adsorção possibilitaram avaliar o modo como o adsorbato interage na superfície do adsorvente. / São Cristóvão, SE
28

Análise enantiosseletiva da mefloquina em plasma: avaliação da técnica de microextração em fase líquida / Enantioselective analysis of mefloquine in plasma: evaluation on the liquid-phase microextration technique

Igor Rafael dos Santos Magalhães 28 July 2006 (has links)
A mefloquina (MQ), fármaco utilizado na profilaxia e tratamento da malária ocasionada por Plasmodium falciparum resistente à cloroquina, é comercializada na forma racêmica. Apresenta disposição cinética estereosseletiva e ação farmacológica diferencial entre os enantiômeros. A maioria dos métodos analíticos desenvolvidos para análise do fármaco em plasma utiliza como técnicas de preparação das amostras, a extração líquido-líquido ou a extração em fase sólida. Por outro lado, a microextração em fase líquida (LPME), técnica recentemente desenvolvida, pode oferecer resultados bastante satisfatórios para amostras complexas, como fluidos biológicos. Portanto, o presente trabalho teve por finalidade o desenvolvimento e validação de um método analítico empregando a cromatografia líquida de alta eficiência com fases estacionárias quirais juntamente com a LPME para a análise enantiosseletiva da MQ em plasma. Empregando-se a coluna Chiralpak AD com fase móvel constituída por hexano/etanol/DEA (97:3:0,05, v/v/v), obteve-se a separação dos enantiômeros da MQ, com tempos de retenção reduzidos e resolução apropriada. Utilizando-se uma membrana capilar de polipropileno, juntamente com éter diexílico (fase orgânica) e ácido perclórico 10 mmol L-1 (fase aceptora) como componentes do sistema de três fases, obteve-se excelente isolamento dos interferentes endógenos aliado a um enriquecimento satisfatório dos analitos, sendo então possível a validação do método desenvolvido. A metodologia otimizada apresentou linearidade satisfatória no intervalo de 50 ? 1500 ng mL-1 com coeficientes de determinação > 0,998 para ambos enantiômeros. Os valores de recuperação absoluta de (-)-(SR)-MQ e (+)-(RS)-MQ foram 33,2% e 35,0%, respectivamente. Precisão e exatidão, avaliadas por estudos intra-ensaio e interensaio, foram < 15% para ambos enantiômeros. Além disso, não foram observadas racemização ou degradação do fármaco durante a preparação das amostras e análise cromatográfica. Posteriormente, o método desenvolvido e validado foi aplicado em um estudo-piloto de disposição cinética em ratos. Verificou-se que a disposição cinética da MQ em ratos foi estereosseletiva, já que maiores concentrações de (+)-(RS)-MQ foram obtidas em todos os tempos de análise avaliados. / Mefloquine (MQ), a drug used for prophylaxis and treatment of malaria caused by chloroquine-resistant strains of Plasmodium falciparum, is commercialized as a racemic mixture. MQ enantiomers demonstrate differential stereoselective dispositions and pharmacodynamic actions. The majority of methods developed for the determination of mefloquine in plasma includes liquid-liquid or solid-phase extraction as sample preparation. On the other hand, liquid-phase microextraction (LPME), a recently developed technique, may offer satisfactory results for complex matrices, such as biological fluids. Therefore, the aim of this work was to develop and validate an analytical method using chiral high-performance liquid chromatography combined with LPME for the enantioselective analysis of MQ in plasma. Employing a Chiralpak AD column with hexane/ethanol/DEA (97:3:0.05, v/v/v) as mobile phase, separation of MQ enantiomers was achieved with short retention times and appropriate resolution. Using a polypropylene-based capillary membrane together with di-n-hexyl ether (organic phase) and 10 mmol L-1 perchloric acid (acceptor phase) as components of a three-phase system, an excelent clean-up of endogenous interferents, allied with a satisfactory enrichment of analytes, was obtained, which allowed method validation. The optimized methodology exhibited good linearity over a 50 - 1500 ng mL-1 range with correlation coefficients of > 0.998 for both enantiomers. The mean recoveries of (-)-(SR)-MQ and (+)-(RS)-MQ were 33.2 and 35.0%, respectively. Precision and accuracy, demonstrated by within-day and between-day assays, were lower than 15% for both enantiomers. Furthermore, no racemization or degradation were seen during sample preparation and chromatographic analysis. Finally, the developed and validated method was applied to a pilot pharmacokinetic assay in rats. An enantiosselective kinetic disposition of MQ enantiomers was observed in rat plasma, as concentrations of (+)-(RS)-MQ were greater than its antipode at all measured times.
29

Desenvolvimento e validação de métodos analíticos para determinação simultânea de fármacos que atuam no controle da hipertensão arterial / Development and validation of analytical methods for simultaneous determination of drugs that act on the control of hypertension.

Claudia Vilela de Oliveira 13 April 2015 (has links)
A hipertensão arterial é um fator de risco de alta prevalência para as doenças cardiovasculares, principalmente no mundo industrializado, aumentando o problema de saúde em virtude do aumento da longevidade e da prevalência de fatores contribuintes como obesidade, sedentarismo e dietas inadequadas. Estima-se que 10% das 55 milhões de mortes que acontecem a cada ano, são consequências da hipertensão arterial. Dois terços desses eventos ocorrem nos países em desenvolvimento, incluindo o Brasil, afetando principalmente a população de menor nível socioeconômico. Diuréticos como hidroclorotiazida associados a betabloqueadores como o metoprolol são exemplos de fármacos utilizados no controle da hipertensão. O presente trabalho teve como objetivo desenvolver, validar e comparar métodos analíticos para a identificação e quantificação simultânea do tartarato de metoprolol e da hidroclorotiazida por eletroforese capilar (CE) e por cromatografia líquida de ultra eficiência (UHPLC). Para a definição das melhores condições de análise e determinação simultânea dos analitos em estudo, e otimização do método, utilizou-se metodologia de superfície de resposta (ou Response Surface Methodology - RSM). O método por CE utilizou um capilar de sílica fundida com comprimento total de 30,2 cm x 50 &#181;m d.i. O tampão utilizado foi tetraborato de sódio 25,0 mmol L-1, injeção hidrodinâmica 0,5 psi/6s, tensão aplicada +15 kV, detecção em 225 nm temperatura a 25ºC. O tartarato de metoprolol e hidroclorotiazida foram separados em 1,2 e 2,1 min, respectivamente .O método por UHPLC foi realizado empregando uma coluna ZORBAX® SB C18 (50 mm x 2,1 mm x 1,8 &#181;m), fase móvel constituída por água:acetornitrila:trietilamina (83:17:0,2 v/v/v), pH 3 ajustado com ácido fosfórico, utilizou vazão de 0,9 mL min-1. A hidroclorotiazida e o tartarato de metoprolol foram separados em 0,7 e 1,0 min, respectivamente. Os métodos analíticos foram validados de acordo com os requerimentos da ANVISA, ICH e Farmacopéia Americana. Os métodos apresentaram boa linearidade com coeficiente de correlação maiores que 0.99, a precisão intra- e inter-day para os tempos de migração foi apropriada (DPR < 2%), a exatidão do método foi comprovada mediante teste de recuperação, obtendo-se valores de 100±2. Portanto, os métodos propostos demonstraram ser lineares, precisos, exatos e rápidos para quantificação simultânea da hidroclorotiazida e do tartarato de metoprolol. E podem ser considerados confiáveis para serem empregados em análise de rotina para controle de qualidade destes produtos farmacêuticos. / Hypertension is a risk factor of high prevalence for cardiovascular diseases, especially in the industrialized world, increasing health problems as a result of increased longevity and the prevalence of contributing factors such as obesity, physical inactivity and inadequate diets. It is estimated that 10% of 55 million deaths that occur each year, are consequences of hypertension. Two-thirds of those events occur in developing countries, including Brazil, affecting mainly the population from lower socioeconomic backgrounds. Diuretics like hydrochlorothiazide associated with beta-blockers such as metoprolol tartrate are examples of drugs used in the control of hypertension. The present work had as objective to develop, validate and compare analytical methods for identification and simultaneous quantification of metoprolol tartrate and hydrochlorothiazide by capillary electrophoresis (CE) and ultra performance liquid chromatography (UHPLC). For the definition of the best conditions of analysis and simultaneous determination of drugs in study, and optimization of the method, it was used response surface methodology (RSM or \"Response Surface Methodology). The CE method used a fused silica capillary with total length of 30.2 cm x 50 &#181;m d.i. The electrolyte used was sodium tetraborate 25,0 mmol L-1, hydrodynamic injection 0.5 psi/6s, applied voltage +15 kV, detection in 225 nm temperature at 25ºC. The metoprolol tartrate and hydrochlorothiazide were separated into 1.2 and 2.1 min, respectively. The UHPLC method was carried out employing a ZORBAX SB® C18 (50 mm x 2.1 mm x 1.8 &#181;m) column, mobile phase consisting of water: acetornitrila: triethylamine (83: 17: 0.2 v/v/v), 3 pH adjusted with phosphoric acid, the flow was 0.9 mL min-1. Hydrochlorothiazide and metoprolol tartrate were separated in 0.7 and 1.0 min, respectively. The analytical methods have been validated in accordance with the requirements of ANVISA, ICH and American Pharmacopoeia. The methods showed good linearity with correlation coefficient greater than 0.99, precision inter and intra day for times of migration was appropriate (DPR < 2%), the accuracy of the method has been proven by recovery test, obtaining values of 100 ± 2. Therefore, the proposed methods have shown to be linear, precise, accurate and fast for simultaneous quantification of hydrochlorothiazide and metoprolol tartrate; and can be considered reliable to be used in routine analysis for quality control of pharmaceutical products.
30

Métodos de análise da rosiglitazona e pioglitazona e de seus principais metabólitos: aplicações em estudos de metabolismo in vitro / Methods for the analysis of rosiglitazone and pioglitazone and their metabolites: application to in vitro metabolism studies

Leandro Augusto Calixto 02 April 2012 (has links)
Estudos de metabolismo in vitro possuem o intuito de caracterizar e quantificar possíveis metabólitos, elucidar as vias metabólicas e sugerir modelos a serem seguidos para a realização de estudos in vivo. Com o intuito de estudar o metabolismo in vitro não estereosseletivo da rosiglitazona (RSG) empregando fração microssomal de fígado de ratos,foi desenvolvida uma metodologia por cromatografia líquida de alta eficiência (HPLC) com detecção UV em 245 nm, para analisar a RSG e seus principais metabólitos, p-hidroxi rosiglitazona (?-OH-R) e N-desmetil rosiglitazona (N-Dm-R). Os analitos foram separados em fase reversa, utilizando uma coluna X-Terra MS C-18 (partículas de 3,5 ?m) e fase móvel composta por água:acetonitrila:ácido acético (85:15:0,5, v/v/v), na vazão de 1 mL min-1. Matrizes biológicas contém um grande excesso de proteínas, lipídeos e outros materiais endógenos que interferem na análise de fármacos e metabólitos, tornando necessário um procedimento adequado de preparação das amostras antes da análise cromatográfica. A microextração em fase líquida com membrana cilíndrica oca (HF-LPME) é uma técnica promissora para a preparação de amostras em estudos de metabolismo in vitro, pois, além de promover o clean-up, promove também o enriquecimento dos analitos na amostra. A HF-LPME foi aplicada pela primeira vez para a extração simultânea desse fármaco e seus metabólitos. O sistema de três fases foi escolhido como o mais apropriado, empregando uma solução de ácido clorídrico como fase aceptora e 1-octanol como solvente orgânico. A otimização dos demais parâmetros foi realizada através de planejamento fatorial fracionário. O método foi validado e foi linear no intervalo de 50-6000 ng mL-1, apresentando limites de quantificação de 50 ng mL-1 e recuperações acima de 47 % para a RSG e seus metabólitos (?-OH-R e N-Dm-R). O método validado foi empregado em um estudo de metabolismo in vitro com fração microssomal de fígado de ratos. Nesse estudo, foi possível estimar as constantes de Michaelis-Menten (Km) e a velocidade inicial máxima (Vmax). N-Dm-R e ?-OH-R apresentaram valores de Vmax de 87,30 ± 8,04 e 51,64 ± 12,25 ?mol min-1 mg proteína-1, respectivamente, enquanto que os valores de Km foram de 58,14 ± 11,85 e 77,84 ± 36,77 mmol L-1, respectivamente. Outros metabólitos foram observados nos cromatogramas e a identificação foi feita por espectrometria de massas: ?rto-hidroxi-rosiglitazona e N-desmetil-hidroxi-rosiglitazona. A RSG é comercializada como uma mistura racêmica, apesar de possuir sua atividade antidiabética relacionada essencialmente com o enantiômero (S). O centro quiral desse fármaco possui um grupo carbonila, por isso, o enantiômero (R) pode se converter no enantiômero (S) ou vice-versa, via tautomerismo cetoenólico. Dados da literatura indicavam que essa racemização poderia ser lenta o suficiente para possibilitar o estudo dos enantiômeros isoladamente. Entretanto, até o momento não há dados sobre a disposição cinética ii e metabolismo enantiosseletivos desse fármaco. Sendo assim, propôs-se o desenvolvimento de metodologias analíticas para estudar a racemização da RSG e seus metabólitos e avaliar a possibilidade de estudar seu metabolismo in vitro de forma estereosseletiva. O método foi desenvolvido empregando HPLC com detecção em 245 nm. A separação dos enantiômeros do fármaco e metabólitos, também quirais, foi obtida empregando uma coluna Chiralcel OJ-H e fase móvel constituída por metanol:etanol (90:10; v/v), na vazão de 0,3 mL min-1. O estudo de racemização mostrou que o fármaco e seus metabólitos são racemizados nas condições em que o estudo de metabolismo é conduzido. Finalmente, para estudar o metabolismo in vitro da pioglitazona (PGZ), foi desenvolvido um método para análise desse fármaco e de seus principais metabólitos, a hidroxi-pioglitazona (M-IV) e a ceto-pioglitazona (M-III) empregando a eletroforese capilar (CE). As análises foram realizadas em capilar de sílica de 50 ?m de diâmetro interno e com comprimento efetivo de 40 cm, utilizando tampão fosfato de sódio 50 mmol L-1, pH 2,5, detecção em 190 nm, tensão de 30 kV e temperatura do capilar de 35 °C. A HF-LPME também foi empregada para a preparação das amostras. O sistema de três fases foi escolhido, empregando solução de ácido clorídrico como fase aceptora e o 1-octanol como solvente orgânico. A otimização dos demais parâmetros foi realizada através de planejamento fatorial fracionário. O método validado foi linear no intervalo de 200 - 25000 ng mL-1 para PGZ e 200 - 2000 ng mL-1 para os metabólitos, apresentando limites de quantificação de 200 ng mL-1 e recuperações acima de 19 % para a RSG e seus metabólitos M-IV e M-III. O método validado foi empregado em um estudo de metabolismo in vitro contendo fração microssomal de fígado de ratos, mas nesse estudo, não foi possível observar a formação dos metabólitos. Entretanto, esse método pode ser usado em outros modelos de metabolismo in vitro (microssomas humanos), nos quais se observa a formação desses metabólitos em concentrações maiores. / In vitro metabolism studies have been used to characterize and to quantify possible metabolites, to elucidate metabolic pathways and to suggest models to perform in vivo studies. So the purpose of this study was to evaluate the in vitro rosiglitazone (RSG) metabolism employing microsomal fraction obtained from rat livers. A high- performance liquid chromatography (HPLC) method with UV detection at 245 nm was developed to analyze RSG and the main metabolites, p-hydroxy rosiglitazone (?-OH-R) e N-desmethyl rosiglitazone (N-Dm-R). The analytes were separated under reversed phase conditions, using a X-Terra MS C-18 column (3.5 ?m particle size) and a mobile phase consisting of water:acetonitrile:acetic acid (85:15:0.5, v/v/v), at a flow rate of 1 mL min-1. Biological matrices contain a large excess of proteins, lipids and other endogenous compounds that interfere in the analysis of drugs and metabolites. So, a suitable sample preparation technique is required. Hollow-fiber liquid phase microextraction (HF-LPME) is a promising technique for the preparation of biological samples. Besides the clean-up, analytes enrichment is also achieved. HF-LPME for the simultaneous analysis of RSG and its main metabolites is described for the first time. The three-phase extraction was performed using hydrochloride acid solution as acceptor phase and 1-octanol as organic solvent. The other parameters were optimized by fractional factorial design. The method was validated and it was linear over the concentration range of 50-6000 ng mL-1, with quantification limits of 50 ng mL-1 and recoveries above 47 %. The validated method was used to estimate Michaelis-Menten (Km) constant and maximum initial velocity (Vmax). N-Dm-R e ?-OH-R showed Vmax values of 87.30 ± 8.04 and 51.64 ± 12.25 ?mol min-1 mg protein-1, respectively, while the Kmvalues were 58.14 ± 11.85 e 77.84 ± 36.77 mmol L-1, respectively. Other possible metabolites were observed in the chromatograms and they were identified by mass spectrometry: ?rtho-hydroxy-rosiglitazone e N-desmethyl-hydroxy-rosiglitazone. RSG is marketed as a racemic mixture although the antidiabetic activity is related essentially to the (S)-enantiomer. The chiral center has a carbonyl group, therefore the (R)-enantiomer could be transformed to the (S)-enantiomer or vice-versa by keto-enolic tautomerism. The literature indicates that this racemization is slow enough to allow the evaluation of the properties of the isolated enantiomers. However, there is no information in the literature about enantioselective RSG kinetic disposition and metabolism. Considering this facts, an analytical procedure was developed to study the racemization of RSG and its metabolites under different conditions and to determine if the enantioselective metabolism would be performed. The method was developed by HPLC with detection at 245 nm. The chiral separation of RSG and metabolites was achieved on a Chiralcel OJ-H column, with the mobile phase consisting of methanol:ethanol (90:10,v/v). The results obtained showed that the racemization occurs under the conditions used in in vitro iv metabolism studies. Finally, to study the in vitro metabolism of pioglitazone (PGZ), another method was developed by capillary electrophoresis (CE) to determine this drug and its main metabolites, hydroxy-pioglitazone (M-IV) and keto-pioglitazone (M-III). The analyses were conducted using a fused silica capillary (50 ?m inner diameter and 40 cm effective length), sodium phosphate buffer 50 mmol L-1, pH 2.5, detection at 190 nm, voltage of 30 kV and capillary temperature of 35°C. HF-LPME was also used for sample preparation with hydrochloride acid solution as acceptor phase and 1-octanol as organic solvent. The other parameters were optimized by fractional factorial design. The method was validated showing to be linear in the concentration range of 200 - 25000 ng mL-1 for PGZ and 200 - 2000 ng mL-1 for the metabolites. Quantification limits were 200 ng mL-1 for all analytes and the recoveries were higher than 19%. The validated method was used to study the in vitro metabolism of PGZ by rat liver microsomal fraction, but it was not possible to observe the formation of the metabolites in this study. However this method could be used in other in vitro metabolism models (human microssomes), in which higher concentrations of these metabolites are observed. Keywords:

Page generated in 0.0558 seconds