• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 127
  • 122
  • 30
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 336
  • 336
  • 142
  • 108
  • 93
  • 83
  • 74
  • 69
  • 62
  • 57
  • 57
  • 53
  • 51
  • 43
  • 40
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
271

A Bayesian least squares support vector machines based framework for fault diagnosis and failure prognosis

Khawaja, Taimoor Saleem 21 July 2010 (has links)
A high-belief low-overhead Prognostics and Health Management (PHM) system is desired for online real-time monitoring of complex non-linear systems operating in a complex (possibly non-Gaussian) noise environment. This thesis presents a Bayesian Least Squares Support Vector Machine (LS-SVM) based framework for fault diagnosis and failure prognosis in nonlinear, non-Gaussian systems. The methodology assumes the availability of real-time process measurements, definition of a set of fault indicators, and the existence of empirical knowledge (or historical data) to characterize both nominal and abnormal operating conditions. An efficient yet powerful Least Squares Support Vector Machine (LS-SVM) algorithm, set within a Bayesian Inference framework, not only allows for the development of real-time algorithms for diagnosis and prognosis but also provides a solid theoretical framework to address key concepts related to classication for diagnosis and regression modeling for prognosis. SVM machines are founded on the principle of Structural Risk Minimization (SRM) which tends to nd a good trade-o between low empirical risk and small capacity. The key features in SVM are the use of non-linear kernels, the absence of local minima, the sparseness of the solution and the capacity control obtained by optimizing the margin. The Bayesian Inference framework linked with LS-SVMs allows a probabilistic interpretation of the results for diagnosis and prognosis. Additional levels of inference provide the much coveted features of adaptability and tunability of the modeling parameters. The two main modules considered in this research are fault diagnosis and failure prognosis. With the goal of designing an efficient and reliable fault diagnosis scheme, a novel Anomaly Detector is suggested based on the LS-SVM machines. The proposed scheme uses only baseline data to construct a 1-class LS-SVM machine which, when presented with online data, is able to distinguish between normal behavior and any abnormal or novel data during real-time operation. The results of the scheme are interpreted as a posterior probability of health (1 - probability of fault). As shown through two case studies in Chapter 3, the scheme is well suited for diagnosing imminent faults in dynamical non-linear systems. Finally, the failure prognosis scheme is based on an incremental weighted Bayesian LS-SVR machine. It is particularly suited for online deployment given the incremental nature of the algorithm and the quick optimization problem solved in the LS-SVR algorithm. By way of kernelization and a Gaussian Mixture Modeling (GMM) scheme, the algorithm can estimate (possibly) non-Gaussian posterior distributions for complex non-linear systems. An efficient regression scheme associated with the more rigorous core algorithm allows for long-term predictions, fault growth estimation with confidence bounds and remaining useful life (RUL) estimation after a fault is detected. The leading contributions of this thesis are (a) the development of a novel Bayesian Anomaly Detector for efficient and reliable Fault Detection and Identification (FDI) based on Least Squares Support Vector Machines , (b) the development of a data-driven real-time architecture for long-term Failure Prognosis using Least Squares Support Vector Machines,(c) Uncertainty representation and management using Bayesian Inference for posterior distribution estimation and hyper-parameter tuning, and finally (d) the statistical characterization of the performance of diagnosis and prognosis algorithms in order to relate the efficiency and reliability of the proposed schemes.
272

An in-depth study into the various factors contributing to the unexplained line faults on a large high voltage network.

Bekker, H. J. J. January 2003 (has links)
The Eskom Transmission Network experiences an exceptionally high number of line faults, the cause of which, may not be correctly identified. This thesis analyses a number of all the possible factors responsible for causing these faults. The objective is to assign probable causes of these faults and that the correct preventative or corrective measures may be planned. The percentage of unexplained line faults is estimated to be 35 % of the total system faults. It is important for the Transmission Group of Eskom to minimise the number of faults. Major efforts to minimise identified faults such as bird streamers, veld fires, sugar cane fIfes, lightning and a hypothesised light pollution, light wetting mechanism has been undertaken by the transmission grid authority. This thesis presents an analysis of the statistical data of the unknown faults (unknown faults is defined as lines that trip due to a reason which could not be identified) that has been undertaken. This analysis takes into account a number of categories of causes of line faults. The period, for which the performance of the lines was analysed for was the years inclusive of 1993 to 1997. The investigation has focused on the identification of the under-performing lines of the main Transmission Network. The identified poorly performing lines have been compared with each other from the perspective ofthe following variables: • Region • Voltage (System Voltage) • Climatic Data Line faults - Time ofDay analysis • Line Faults - Time of Year analysis. The analysis indicates that the majority of unexplained flashovers occur between 22 :00 and 07:00 the following morning (Britten et al, 1999). Almost all of the under performing lines in South Africa fall in the sub-tropical/humid climatic area. All the lines studied are insulated with standard glass disc insulators. The analysis indicated that most of the unexplained line faults occur during the months when the seasons change, e.g. from autumn to winter. The analysis further indicates that most unexplained line faults occurred during the months of April to May and August to September. Of note is that during the period of this investigation bird guarding was performed on some lines. Installing bird guards may reduce those line faults that are caused by bird streamers. However, the bird pollution (deposited on glass disc insulators) that is not washed off at the same time as the bird guard installation may cause the line to trip due to the combination of the pollution and wetting resulting in a pollution type flashover. This is a possible cause of some unexplained line faults that occur from April to May. Bird streamers are also identified as the most probable cause of the unexplained faults which occur during the late evening periods (22:00 - 00:00). Pollution (with wetting) during the early morning periods may result in faults for the period 00:00 to 02:00. Line faults in the early morning periods (04:00 - 7:00) could be due to bird streamers or pollution and wetting, depending on the time of year in which the faults occurs. / Thesis (M.Sc.)-University of Natal, Durban, 2003.
273

On-line condition monitoring and detection of stator and rotor faults in induction motors.

Supangat, Randy January 2008 (has links)
Induction motors are reliable and widely used in industrialised nations. However induction motors, like any other machine, will eventually fail. If the failure is not anticipated, it can result in a significant revenue loss. Therefore, there is a strong need to develop an efficient maintenance program. The most cost-effective solution is condition-based maintenance. An effective condition-based maintenance program requires an on-line condition monitoring system that can diagnose the condition of an induction motor in order to determine the types of faults and their severity while the motor is under a normal operating condition. The work in this thesis investigates the detection of stator and rotor faults (i.e. shorted turn faults, eccentricity faults, and broken rotor bar faults) using three types of sensor signals (i.e. current, leakage flux, and vibration) under different loading conditions. The work is based on an extensive series of sensor measurements taken using a number of nominally identical healthy machines (2.2 kW) and custom-modified machines (2.2 kW) with configurable stator and rotor fault settings. The thesis starts by investigating the estimation of rotor speed and rotor slot number. These two parameters are important in determining the fault frequency components that are used for detecting the stator and rotor faults. The rotor speed investigation compares four different estimation methods from the three different sensor signal types. It is found that the speed estimation techniques based on the eccentricity harmonics and the rotor frequency in the stator current, the axial leakage flux, and the motor vibration sensor signals can detect the rotor speed very accurately even when the load is as low as 2%. Similarly, this thesis proposes three different rotor slot number estimation techniques from the three different types of sensors and demonstrates that all three techniques can estimate the rotor slot number accurately. In addition, it is shown that the reliability of the estimation techniques can be increased significantly when the three techniques are combined. The shorted turn investigation in this thesis examines and compares potential shorted turn features in the three sensor signal types under five different fault severities and ten different loading conditions. The useful shorted turn features are identified in the thesis, and then examined against variations between the healthy machines in order to determine the loads and the fault severities in which the feature can reliably detect the faults. The results show that the feature based on the EPVA (extended Park’s vector approach) is the best method. This feature can detect turn to turn faults with a severity of 3.5% or greater at loads greater than 20% and phase to phase turn faults with a severity of 1.7% or greater under all loading conditions. However, estimating the fault severity is generally found to be difficult. The thesis also examines the feasibility of detecting static eccentricity faults using the different types of sensor signals under ten different loading conditions. The thesis compares potential eccentricity features under nine different fault severities. The useful features are identified and then combined through weighted linear combination (WLC) in order to produce a better eccentricity fault indicator. The indicator begins to show significant magnitude variation when the fault severity is greater than or equal to 25% and the load is greater than or equal to 25%. The experimental results show that detecting the static eccentricity faults is possible but estimating the fault severity may be difficult. Furthermore, the effects of misalignment faults on the useful eccentricity features are investigated. In this thesis, the analysis of broken rotor bar faults is performed under motor starting and rundown operation. The starting analysis introduces a new approach to detect broken rotor bar faults that utilises the wavelet transform of the envelope of the starting current waveform. The results of the wavelet transform are then processed in order to develop a normalised parameter, called the wavelet indicator. It is found that the wavelet indicator can detect a single broken bar under all loading conditions during motor starting operation. The indicator also increases its magnitude as the severity of the fault increases. On the other hand, the rundown analysis proposes several broken rotor bar fault detection techniques which utilise the induced voltage in the stator windings and the stator magnetic flux linkage after supply disconnection. The experimental results show that detecting the faults during rundown is generally difficult. However, the wavelet approach, which is based on monitoring changes in the motor torque for a given slip, seems to give the best result. / Thesis (Ph.D.) -- University of Adelaide, School of Electrical and Electronic Engineering, 2008
274

Classificação de falhas em maquinas eletricas usando redes neurais, modelos wavelet e medidas de informação

Silva, Lyvia Regina Biagi 21 February 2014 (has links)
CAPES; CNPq / Este trabalho apresenta uma proposta de metodologia para detecção e classificação de falhas em motores de indução trifásicos ligados diretamente à rede elétrica. O método proposto é baseado na análise dos sinais de corrente do estator, com e sem a presença de falhas nos rolamentos, estator e rotor. Um dos efeitos desses tipos de falhas é o aparecimento de componentes de frequência específicas, relacionados à velocidade de rotação da máquina. Os sinais foram analisados usando a decomposição wavelet-packet, que permite a avaliação dos sinais em bandas de frequência de tamanhos variáveis. A partir dessa decomposição, aplicaram-se medidas de previsibilidade, como entropia relativa, potência de previsão e variância de erro normalizada, obtida com a análise de componentes previsíveis. Com essas medidas, foi possível verificar quais componentes da decomposição são mais previsíveis. Neste trabalho, a variância de erro normalizada e a potência de previsão foram utilizadas como entradas para três topologias de redes neurais artificiais classificadoras: perceptron multicamadas, redes de funções de base radial e mapas auto-organizáveis de Kohonen. Foram testados seis diferentes vetores de entrada para as redes neurais, utilizando medidas de previsibilidade e número de elementos dos vetores variados. Os ensaios foram realizados considerando amostras de sinal de diferentes motores, com vários tipos de falha, operando sob diversos regimes de torque e condições de desequilíbrio de tensão. Primeiramente, os sinais foram classificados em dois padrões: com e sem a presença de falhas. Posteriormente, detectou-se o tipo de falha presente nos sinais: rolamento, estator ou rotor. Por último, as amostras foram classificadas dentro do subgrupo de falha em que estavam presentes. / This work presents a methodology for diagnosis and classification of faults in three-phase induction motors connected directly to the power grid. The proposed method is based on the analysis of the stator current signals, with and without the presence of faults in the bearings, stator and rotor. These faults cause the presence of specific frequency components that are related to the machine rotational speed. The signals were analyzed using wavelet-packet decomposition, which allows a multiresolution evaluation of the signals. Using this decomposition, we estimated some predictability measures, such as relative entropy, predictive power and normalized error variance, obtained with the predictability component analysis. With this measures, we verified which were the most predictable components. In this work, normalized error variance and the predictive power were used as inputs to three topologies of artificial neural networks used as classifiers: multilayer perceptron, radial basis function and Kohonen self-organizing maps. We tested six different input vectors to the artificial neural networks, in which we vary the predictability measures and the number of elements of the vectors. The studies were performed considering samples of signals from different motors, with various kinds of faults, working under several load conditions and with voltage unbalance. The signals were firstly classified in two patterns: with and without the presence of faults. After, we detected the kind of fault was present in the signal: bearing, stator or rotor fault. Last, the samples were classified inside the subgroup in which they were.
275

Localização de faltas em alimentadores primários de distribuição de energia com a presença da geração distribuída

Nunes, José Ubirajara Nuñez de January 2010 (has links)
A automatização dos sistemas de distribuição de energia e a integração de energias renováveis são duas importantes iniciativas atuais em sistemas elétricos de potência. A redução no impacto ambiental e o baixo custo comparado às grandes plantas convencionais são fatores que motivam a conexão da geração distribuída nos sistemas de distribuição. Apesar dos benefícios ambientais e econômicos obtidos com esta nova tecnologia, esta pode influenciar na operação do sistema, conduzindo a impactos técnicos que devem ser identificados. O impacto mais visível encontra-se na alteração do fluxo de potência. O alto nível de geração distribuída altera a natureza das redes de distribuição, de redes passivas, com um único sentido de fluxo de potência, para redes ativas, onde a potência flui em vários sentidos. Por conseqüência, a magnitude e a direção das correntes de falta no sistema também são modificadas. Este fato requer um ajuste dos sistemas de proteção, os quais são geralmente concebidos para operar em uma rede puramente passiva. Diversas abordagens sobre localização de faltas fundamentadas na impedância para sistemas radiais foram apresentadas em anos recentes na literatura. Estas técnicas apresentam limitações quando aplicadas a sistemas de distribuição com a presença da geração distribuída. Algumas técnicas de localização de faltas fundamentadas na impedância de seqüência positiva foram recentemente desenvolvidas a fim de incluir a presença da geração distribuída. No entanto, os sistemas de distribuição são inerentemente desequilibrados e esta característica diminui a exatidão das técnicas baseadas nas componentes modais ou de seqüência. Motivado por estes fatos, o presente trabalho ilustra os desenvolvimentos propostos em uma metodologia de localização de faltas baseada na impedância aparente utilizando a representação do sistema por coordenadas de fase. O algoritmo propõe um modelo ativo do sistema caso a falta ocorra a montante da geração distribuída, estimando a contribuição de corrente da extremidade remota da seção faltosa. Além disso, este trabalho fundamenta-se na análise pré-falta do sistema, utilizada para a determinação das impedâncias equivalentes e para a estimativa da tensão interna da máquina. O método considera a tensão interna da máquina constante entre os períodos pré-falta e durante a falta, a fim de estimar a corrente de falta do gerador, possibilitando a atualização correta das tensões e correntes faltosas do sistema. A análise numérica é realizada através de simulações computacionais em um alimentador teste sem a presença de ramificações laterais sob diferentes níveis de geração distribuída. Os resultados são comparados com técnicas atuais que compõem o estado da arte de localização de faltas a fim de avaliar o impacto da geração distribuída nas referidas metodologias. Com base nesses resultados é possível apresentar algumas melhorias obtidas através das extensões propostas. / The automation for power distribution systems and integration of renewable energy are two important current initiatives on electric power systems. The reduction in environmental impact and low cost compared to large conventional plants are factors that motivate the connection of distributed generation in distribution systems. Despite the environmental and economic benefits obtained with this new technology, this can affect the system operation, leading to technical impacts to be identified. The most visible impact is the change in the power flow. The high level of distributed generation changes the nature of distribution networks, from passive networks with a single direction of power flow, for active networks, where power flows in various directions. Consequently, the magnitude and direction of fault currents in the system are also modified. This requires an adjustment of the protection systems, which are generally designed to operate in a purely passive network. Several approaches to fault location based on impedance to radial systems were reported in the literature. These techniques have limitations when applied to distributed generation systems. Some recent positive-sequence impedance based fault location algorithms have been developed to consider the presence of distributed generation. However, the distribution systems are inherently unbalanced and this reduces the accuracy of modal or sequence components based techniques. Motivated by these, this presents proposed developments on a apparent impedance-based fault location methodology using the system representation by phase coordinates. The algorithm proposes an active system model if the failure occurs forward to the distributed generation, estimating the contribution of current from the remote end section of the fault. Moreover, this work is based on analysis of the pre-fault system, used to determine the equivalent impedances and to estimate the machine internal voltage. The method treats the machine internal voltage as constant between the pre and the fault period, in order to estimate the fault current infeed by generator. Numerical analysis is carried out through computer simulations on a test feeder without the presence of ramifications at different levels of distributed generation. The results are compared with current techniques that make up the state of the art of fault location in order to assess the impact of distributed generation in these methodologies. Based on these results it is possible to make some improvements resulting from the proposed extensions.
276

Diagnóstico de faltas em sistemas de subtransmissão : uma formulação baseada na Transformada Wavelet contínua

Iurinic, Leonardo Ulises January 2012 (has links)
As faltas podem ocorrer em diversos componentes de um sistema elétrico de potência, dentre os quais as linhas de transmissão se destacam como elementos susceptíveis. Devido a suas dimensões físicas, ambiente de operação e interconexão com outros sistemas, a localização exata de uma falta em uma linha de transmissão não é trivial dificultando a tarefa das equipes de manutenção para recomposição do fornecimento de energia. Neste contexto, este trabalho apresenta uma metodologia computacional desenvolvida em ambiente MATLAB® para diagnóstico de faltas em linhas de transmissão baseada na análise de transitórios de alta freqüência nas tensões do sistema. A abordagem desenvolvida neste trabalho inicialmente utiliza a equação de Park para achar a tensão zero, direta e em quadratura e posteriormente detectar a ocorrência da falta através do coeficiente de diferenças. Posteriormente, a teoria de ondas viajantes associada à transformada wavelet contínua são utilizadas objetivando determinar a frequência característica do sinal transitório, a qual é relacionada com o local da falta. Para validar o algoritmo de localização proposto foram realizadas diversas simulações de faltas com o programa ATP (Alternative Transient Program) utilizando dados de uma linha aérea real. A efetividade da abordagem proposta foi avaliada considerando a resistência de falta, o ângulo de incidência da falta e a impedância de curto-circuito do sistema. Os resultados promissores demonstraram a aplicabilidade da formulação proposta para localização faltas em linhas de transmissão aéreas utilizando medições oscilográficas digitais de apenas um terminal. / Faults can occur in several components of an electric power system, among which the transmission line stands out. Due to its physical dimensions, operating environment and interconnection systems, the exact transmission line fault location is non-trivial hindering maintenance crew system restoration. In this context, this work presents a computational methodology developed in MATLAB® environment for fault diagnosis on transmission lines based on voltage high frequency transient analysis. Thus, the approach adopted in this work use firstly the Park equations to find the zero, direct and quadrature voltage and then detect the fault occurrence through the difference coefficient. After, the traveling wave theory associated with continuous wavelet transform application is used for determining the characteristic frequency of the transient signal, which is correlated with the fault location. To validate the proposed fault location algorithm, several fault simulations were executed using ATP software using real overhead line data. The proposed fault location scheme performance was evaluated considering the fault resistance, inception fault angle and short-circuit impedance of the system. The promising results demonstrate the applicability of the proposed formulation for fault location in overhead transmission lines, using one terminal digital oscillographic measurement.
277

Localização de defeitos em alimentadores primários subterrâneos : formulação estendida baseada na impedância aparente

Filomena, André Darós January 2008 (has links)
O presente trabalho apresenta uma abordagem estendida para o diagnóstico de faltas em sistemas subterrâneos de distribuição de energia. O esquema proposto desenvolve modificações às técnicas de localização de defeitos em sistemas de distribuição aéreos baseadas no cálculo da impedância aparente, adaptando-as para a aplicação em alimentadores primários de topologia subterrânea. Sistemas subterrâneos estão associados à alta confiabilidade, com índices reduzidos de interrupção devido a suas características construtivas, que impedem a ocorrência de perturbações devido a fenômenos climáticos, mecânicos ou humanos. No entanto, as falhas em cabos subterrâneos são tipicamente permanentes, exigindo a substituição da seção de linha defeituosa para o restabelecimento do sistema. De forma distinta às redes aéreas, onde a localização de defeitos pode ser realizada por meio de inspeções visuais, a topologia subterrânea impossibilita a utilização desta abordagem. Embora o processo de digitalização dos esquemas de proteção de alimentadores primários tenha incentivado o desenvolvimento de inúmeras metodologias para a localização de defeitos em redes de distribuição aéreas, características típicas de redes de distribuição subterrâneas não foram contempladas. Nestes sistemas, a aplicação das técnicas desenvolvidas para sistemas aéreos resulta em estimativas errôneas da distância da falta. O esquema proposto visa a superar esta deficiência dos algoritmos de localização tradicionais, adaptando-os às características típicas de redes de distribuição subterrâneas. A formulação desenvolvida se baseia no cálculo da impedância aparente, o qual poderá ser incorporado como sub-rotina de relés de proteção de arquitetura digital. Além de disponibilizar a estimativa da distância da falta, o esquema de localização de defeitos proposto obtém uma estimativa das resistências de falta associadas à perturbação. A metodologia utiliza como dados de entrada os sinais de tensão e corrente referentes aos períodos de pré-falta e durante a perturbação, e propõe uma compensação da componente capacitiva, característica típica e não-desprezível de cabos subterrâneos. De modo a contemplar a existência de ramificações laterais, o esquema de localização propõe a utilização de sistemas radiais equivalentes, determinados a partir de rotinas de fluxo de potência trifásico. Tendo em vista o comportamento randômico do carregamento em sistemas de distribuição, a metodologia propõe, ainda, uma análise do perfil de carga durante o período pré-falta. Para possibilitar uma análise da eficiência do método proposto, testes comparativos com uma técnica de localização de defeitos para redes de distribuição de topologia aérea recentemente proposta foram realizados. De modo a validar o esquema de localização de defeitos proposto, foram executadas inúmeras simulações computacionais a partir de dados reais de um alimentador subterrâneo. O desempenho do esquema de diagnóstico de faltas foi avaliado frente aos aspectos de: resistência de falta, distância da falta, ângulo de incidência de falta, existência de cargas desequilibradas e variações no carregamento do sistema. Os resultados obtidos demonstram a viabilidade da aplicação da metodologia proposta para a localização de defeitos em sistemas de distribuição subterrâneos. / This work presents an extended approach for underground power distribution system fault location. The scheme develops modifications in the proposed impedance-based fault location techniques for overhead distribution systems, adapting it for underground feeders. Under-ground systems are associated to high reliability, with low interruption rates due to its con-struction characteristics, which avoid the fault occurrence from climatic, mechanics or human interference. However, the underground cables damages are typically permanent, requesting the damaged line section substitution before system restoration. Fault location on overhead systems can be assisted by visual inspection, on underground system, this approach can not used. Although the primary feeder protection scheme's digitalization process has stimulated the development of several fault location schemes for overhead feeders, typical underground's system characteristics were not considered. In these systems, the application of the techniques used on overhead systems results in erroneous fault distance estimates. The proposed methodology aims to overcome this limitation of traditional fault location algorithms, adapting it to the typical underground systems characteristics. The proposed formulation is based on the apparent impedance calculation, and can be included as a sub-routine in digital protection relays. Besides the fault distance estimates, the fault diagnosis scheme also calculates the fault resistances associated to each disturbance. The fault location scheme uses as input data the voltage's and current's signals before and during the fault, and also proposes a capacitive current compensation. The fault location technique also proposes the usage of equivalent radial systems, calculated through three-phase load flow techniques, to allow the algorithm coverage on laterals and sub-laterals. Due to the random load profile of distribution systems, the technique develops a load profile analysis during the pre-fault period. In order to provide efficiency analysis of the proposed formulation, comparative testes with a recently proposed fault location technique was realized. To validate the proposed fault location algorithm, several fault simulations were executed using real underground feeder data. The proposed fault location scheme performance was evaluated considering the following aspects: fault resistance, fault distance and inception fault angle. Also, the methodology was analyzed considering different load profiles, including unbalanced loads and load variation. The obtained results demonstrate the applicability of the proposed formulation for fault location in underground distribution systems.
278

Localização de faltas de alta impedância em sistemas de distribuição de energia : uma abordagem baseada na estimação de parâmetros associados a modelos no domínio do tempo

Iurinic, Leonardo Ulises January 2016 (has links)
A detecção de um tipo particular de falta, denominado de alta impedância, tem sido há muito tempo um desafio para a engenharia de proteção. Por outro lado, se a detecção é realizada com sucesso, ações preventivas e de manutenção devem ser tomadas para evitar prejuízos potenciais. Nesse contexto, os métodos de localização de faltas assumem importante papel, pois contribuem para a rápida restauração do sistema. Entretanto, os métodos clássicos, em particular as formulações a um terminal, não consideram modelos realísticos de faltas de alta impedância na sua formulação. Este tipo de falta se caracteriza pelo contato de um condutor energizado com uma superfície de elevada resistência elétrica, em que o comportamento da tensão em função da corrente apresenta uma característica não linear. Desta forma, esta tese propõe uma nova formulação para a localização de faltas de alta impedância em sistemas de distribuição de energia elétrica, com medições a um terminal, que considere tal efeito. A formulação é proposta para estimar a distância da falta em linhas de distribuição utilizando o método de estimação por mínimos quadrados, desenvolvendo um modelo no domínio do tempo do sistema elétrico e um modelo de falta de alta impedância composto por diodos antiparalelos. Mediante o modelo do sistema elétrico, é possível estimar a distância da falta, juntamente com os parâmetros da falta de alta impedância, usando sinais provenientes de um terminal, como um problema de otimização. Primeiramente, não considerando o efeito capacitivo das linhas, um modelo linear no domínio do tempo é obtido e um estimador de mínimos quadrados linear é proposto. Posteriormente, considerando o efeito capacitivo das linhas, um modelo não linear no domínio do tempo é obtido e um algoritmo de descida é proposto para a estimação dos parâmetros. Os estudos de caso foram realizados no sistema de 13 barras da IEEE modelado no Alternative Transient Program. Em todas as condições simuladas, os resultados obtidos mostraram um desempenho similar da técnica proposta com ou sem a consideração da capacitância das linhas, sendo assim, por simplicidade, optou-se pela desconsideração da capacitância. Os resultados evidenciaram que a técnica de localização de faltas proposta não mostra diferença no seu desempenho com variações do ângulo de incidência da falta e melhora quando o carregamento do sistema diminui. O erro relacionado à estimativa da distância da falta mostra-se, em geral, superior ao erro cometido ao estimar os parâmetros da falta de alta impedância. Por outro lado, os estudos de caso mostram um grande potencial para aplicar a técnica proposta como um detector e classificador de faltas de alta impedância. / High impedance fault location has always been a challenge for protection engineering. On the other hand, if this task is successfully realized maintenance action could be performed in order to avoid potential injuries. For an effective protection scheme the high impedance fault location should be performed, but a lack of research on this area is noted. This thesis proposes a new analytical formulation for high impedance fault location in power systems. The approach is developed in time domain, considering a high impedance fault model composed by two antiparallel diodes. Using this model, the fault distance and fault parameters are estimated as a minimization problem, allowing the location of the fault using one terminal signals. Firstly, the line capacitance is not considered and a linear model in time domain is obtained. In this case, the linear least square estimator is used for parameter estimation. In a second moment, the line capacitance is considered and a non-linear model in time domain is obtained. Hence, a steepest descent based estimator is proposed in order to estimate the parameters. Studies were carried out with the IEEE 13 bus modeled in the Alternative Transient Program. In view of the test results, the non-consideration of line capacitance resulted in similar accuracy in relation to its consideration. The method also is insensitive to the fault inception instant and the reduction of system load reduces the errors related to the estimations. The error related to fault distance estimation is in general greater than the estimation of the high impedance fault parameters. On the other hand, case studies shows the great potential of the technique as a high impedance fault detector method.
279

Localização de defeitos em alimentadores primários subterrâneos : formulação estendida baseada na impedância aparente

Filomena, André Darós January 2008 (has links)
O presente trabalho apresenta uma abordagem estendida para o diagnóstico de faltas em sistemas subterrâneos de distribuição de energia. O esquema proposto desenvolve modificações às técnicas de localização de defeitos em sistemas de distribuição aéreos baseadas no cálculo da impedância aparente, adaptando-as para a aplicação em alimentadores primários de topologia subterrânea. Sistemas subterrâneos estão associados à alta confiabilidade, com índices reduzidos de interrupção devido a suas características construtivas, que impedem a ocorrência de perturbações devido a fenômenos climáticos, mecânicos ou humanos. No entanto, as falhas em cabos subterrâneos são tipicamente permanentes, exigindo a substituição da seção de linha defeituosa para o restabelecimento do sistema. De forma distinta às redes aéreas, onde a localização de defeitos pode ser realizada por meio de inspeções visuais, a topologia subterrânea impossibilita a utilização desta abordagem. Embora o processo de digitalização dos esquemas de proteção de alimentadores primários tenha incentivado o desenvolvimento de inúmeras metodologias para a localização de defeitos em redes de distribuição aéreas, características típicas de redes de distribuição subterrâneas não foram contempladas. Nestes sistemas, a aplicação das técnicas desenvolvidas para sistemas aéreos resulta em estimativas errôneas da distância da falta. O esquema proposto visa a superar esta deficiência dos algoritmos de localização tradicionais, adaptando-os às características típicas de redes de distribuição subterrâneas. A formulação desenvolvida se baseia no cálculo da impedância aparente, o qual poderá ser incorporado como sub-rotina de relés de proteção de arquitetura digital. Além de disponibilizar a estimativa da distância da falta, o esquema de localização de defeitos proposto obtém uma estimativa das resistências de falta associadas à perturbação. A metodologia utiliza como dados de entrada os sinais de tensão e corrente referentes aos períodos de pré-falta e durante a perturbação, e propõe uma compensação da componente capacitiva, característica típica e não-desprezível de cabos subterrâneos. De modo a contemplar a existência de ramificações laterais, o esquema de localização propõe a utilização de sistemas radiais equivalentes, determinados a partir de rotinas de fluxo de potência trifásico. Tendo em vista o comportamento randômico do carregamento em sistemas de distribuição, a metodologia propõe, ainda, uma análise do perfil de carga durante o período pré-falta. Para possibilitar uma análise da eficiência do método proposto, testes comparativos com uma técnica de localização de defeitos para redes de distribuição de topologia aérea recentemente proposta foram realizados. De modo a validar o esquema de localização de defeitos proposto, foram executadas inúmeras simulações computacionais a partir de dados reais de um alimentador subterrâneo. O desempenho do esquema de diagnóstico de faltas foi avaliado frente aos aspectos de: resistência de falta, distância da falta, ângulo de incidência de falta, existência de cargas desequilibradas e variações no carregamento do sistema. Os resultados obtidos demonstram a viabilidade da aplicação da metodologia proposta para a localização de defeitos em sistemas de distribuição subterrâneos. / This work presents an extended approach for underground power distribution system fault location. The scheme develops modifications in the proposed impedance-based fault location techniques for overhead distribution systems, adapting it for underground feeders. Under-ground systems are associated to high reliability, with low interruption rates due to its con-struction characteristics, which avoid the fault occurrence from climatic, mechanics or human interference. However, the underground cables damages are typically permanent, requesting the damaged line section substitution before system restoration. Fault location on overhead systems can be assisted by visual inspection, on underground system, this approach can not used. Although the primary feeder protection scheme's digitalization process has stimulated the development of several fault location schemes for overhead feeders, typical underground's system characteristics were not considered. In these systems, the application of the techniques used on overhead systems results in erroneous fault distance estimates. The proposed methodology aims to overcome this limitation of traditional fault location algorithms, adapting it to the typical underground systems characteristics. The proposed formulation is based on the apparent impedance calculation, and can be included as a sub-routine in digital protection relays. Besides the fault distance estimates, the fault diagnosis scheme also calculates the fault resistances associated to each disturbance. The fault location scheme uses as input data the voltage's and current's signals before and during the fault, and also proposes a capacitive current compensation. The fault location technique also proposes the usage of equivalent radial systems, calculated through three-phase load flow techniques, to allow the algorithm coverage on laterals and sub-laterals. Due to the random load profile of distribution systems, the technique develops a load profile analysis during the pre-fault period. In order to provide efficiency analysis of the proposed formulation, comparative testes with a recently proposed fault location technique was realized. To validate the proposed fault location algorithm, several fault simulations were executed using real underground feeder data. The proposed fault location scheme performance was evaluated considering the following aspects: fault resistance, fault distance and inception fault angle. Also, the methodology was analyzed considering different load profiles, including unbalanced loads and load variation. The obtained results demonstrate the applicability of the proposed formulation for fault location in underground distribution systems.
280

Localização de faltas em alimentadores primários de distribuição de energia com a presença da geração distribuída

Nunes, José Ubirajara Nuñez de January 2010 (has links)
A automatização dos sistemas de distribuição de energia e a integração de energias renováveis são duas importantes iniciativas atuais em sistemas elétricos de potência. A redução no impacto ambiental e o baixo custo comparado às grandes plantas convencionais são fatores que motivam a conexão da geração distribuída nos sistemas de distribuição. Apesar dos benefícios ambientais e econômicos obtidos com esta nova tecnologia, esta pode influenciar na operação do sistema, conduzindo a impactos técnicos que devem ser identificados. O impacto mais visível encontra-se na alteração do fluxo de potência. O alto nível de geração distribuída altera a natureza das redes de distribuição, de redes passivas, com um único sentido de fluxo de potência, para redes ativas, onde a potência flui em vários sentidos. Por conseqüência, a magnitude e a direção das correntes de falta no sistema também são modificadas. Este fato requer um ajuste dos sistemas de proteção, os quais são geralmente concebidos para operar em uma rede puramente passiva. Diversas abordagens sobre localização de faltas fundamentadas na impedância para sistemas radiais foram apresentadas em anos recentes na literatura. Estas técnicas apresentam limitações quando aplicadas a sistemas de distribuição com a presença da geração distribuída. Algumas técnicas de localização de faltas fundamentadas na impedância de seqüência positiva foram recentemente desenvolvidas a fim de incluir a presença da geração distribuída. No entanto, os sistemas de distribuição são inerentemente desequilibrados e esta característica diminui a exatidão das técnicas baseadas nas componentes modais ou de seqüência. Motivado por estes fatos, o presente trabalho ilustra os desenvolvimentos propostos em uma metodologia de localização de faltas baseada na impedância aparente utilizando a representação do sistema por coordenadas de fase. O algoritmo propõe um modelo ativo do sistema caso a falta ocorra a montante da geração distribuída, estimando a contribuição de corrente da extremidade remota da seção faltosa. Além disso, este trabalho fundamenta-se na análise pré-falta do sistema, utilizada para a determinação das impedâncias equivalentes e para a estimativa da tensão interna da máquina. O método considera a tensão interna da máquina constante entre os períodos pré-falta e durante a falta, a fim de estimar a corrente de falta do gerador, possibilitando a atualização correta das tensões e correntes faltosas do sistema. A análise numérica é realizada através de simulações computacionais em um alimentador teste sem a presença de ramificações laterais sob diferentes níveis de geração distribuída. Os resultados são comparados com técnicas atuais que compõem o estado da arte de localização de faltas a fim de avaliar o impacto da geração distribuída nas referidas metodologias. Com base nesses resultados é possível apresentar algumas melhorias obtidas através das extensões propostas. / The automation for power distribution systems and integration of renewable energy are two important current initiatives on electric power systems. The reduction in environmental impact and low cost compared to large conventional plants are factors that motivate the connection of distributed generation in distribution systems. Despite the environmental and economic benefits obtained with this new technology, this can affect the system operation, leading to technical impacts to be identified. The most visible impact is the change in the power flow. The high level of distributed generation changes the nature of distribution networks, from passive networks with a single direction of power flow, for active networks, where power flows in various directions. Consequently, the magnitude and direction of fault currents in the system are also modified. This requires an adjustment of the protection systems, which are generally designed to operate in a purely passive network. Several approaches to fault location based on impedance to radial systems were reported in the literature. These techniques have limitations when applied to distributed generation systems. Some recent positive-sequence impedance based fault location algorithms have been developed to consider the presence of distributed generation. However, the distribution systems are inherently unbalanced and this reduces the accuracy of modal or sequence components based techniques. Motivated by these, this presents proposed developments on a apparent impedance-based fault location methodology using the system representation by phase coordinates. The algorithm proposes an active system model if the failure occurs forward to the distributed generation, estimating the contribution of current from the remote end section of the fault. Moreover, this work is based on analysis of the pre-fault system, used to determine the equivalent impedances and to estimate the machine internal voltage. The method treats the machine internal voltage as constant between the pre and the fault period, in order to estimate the fault current infeed by generator. Numerical analysis is carried out through computer simulations on a test feeder without the presence of ramifications at different levels of distributed generation. The results are compared with current techniques that make up the state of the art of fault location in order to assess the impact of distributed generation in these methodologies. Based on these results it is possible to make some improvements resulting from the proposed extensions.

Page generated in 0.0788 seconds