• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 13
  • Tagged with
  • 13
  • 13
  • 9
  • 7
  • 6
  • 6
  • 5
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Avaliação da resistência à fratura de prótese parcial fixa provisória confeccionada sobre componentes do tipo UCLA em titânio - efeito de diversos reforços / Fracture resistance evaluation of provisional fixed partial denture made on titanium ucla components several reinforcements effect

Almonte, Thania Grisel Rodriguez 31 May 2005 (has links)
As restaurações provisórias no tratamento reabilitador oral são de suma importância. Por isso é preocupante que os materiais utilizados para a execução das mesmas sejam críticos com relação à sua resistência e longevidade, principalmente, quando estas são executadas em tratamentos prolongados e/ou em espaços desdentados extensos. O objetivo deste trabalho foi avaliar em 4 grupos reforçados, compostos por 9 espécimes cada um, a resistência e o modo de fratura, de uma resina acrílica poli(metilmetacrilato) auto-polimerizável (Dencor® - Clássico®, São Paulo, SP, Brasil) utilizada para restaurações provisórias quando reforçada com fibras de vidro (Fibrante® e Interlig® - Angelus®, Londrina, PR, Brasil), fibras de aramida (Kevlar® - Du Pont®, USA) y fio ortodôntico &#x2205; 0, 7mm. E um grupo controle sem nenhum tipo de reforço, com a mesma quantidade de corpos de prova. A análise dos resultados (ANOVA, p < 0,05), para o teste de resistência, mostrou haver diferença estatística entre os grupos. O teste de Tukey encontrou que os grupos reforçados, aqueles que alcançaram maior média de resistência à fratura foram os que utilizaram a fibra de vidro trançada pré-impregnada com resina composta foto-polimerizável, Interlig® (1083 N); a fibra de vidro unidirecional préimpregnada com dimetacrilato de glicol, Fibrante® (1022 N) e a fibra de poli(aramida) unidirecional sem pré-impregnação, Kevlar® 29, aumentando em 26%, 22% e 17%, respectivamente, esta resistência em relação ao grupo controle (800 N), não havendo diferença estatística significante entre eles. O grupo reforçado com fio de aço com &#x2205; 0,7 mm (871 N) apareceu em seguida com uma resistência somente 8% maior e semelhante àquela apresentada pelo grupo controle sem reforço. A análise das fraturas concorreu com a elaboração de um novo sistema de classificação dividindo-as em quatro tipos: Ausente, Parcial, Total Não Separada e Total Separada. As fraturas dos espécimes reforçados foram consideradas mais favoráveis ocorrendo, predominantemente, os tipos Ausente e Parcial. / Provisional restorations are of ultimate importance in the oral rehabilitation treatment. Thus, clinicians have to bear in mind that materials used for their fabrication are critical due to its longevity and strength, when these are done for longterm therapy and/or large edentulous spaces. The aim of this work was to evaluate the flexural resistance and fracture mode of an auto-cure polymethylmetacrilate resin (Dencor® - Classico® , Sao Paulo, SP, Brasil) used for provisional restorations and reinforced with four materials. Samples were divided in four groups of nine each, as the following: glass fiber (Fibrante® and Interlig® Angelus®, Londrina, PR, Brasil), aramide fibers (Kevlar® Du Pont®, USA), and orthodontic wire &#x2205; 0,7mm. one group whitout reinforcement served as control. Data was submitted to statistical analysis with one-way ANOVA (p<.05) test. Results showed statistically significant difference among the groups. Tukeys test showed that glass-fiber Interlig® exhibited the greatest value of flexural strength (1083 N); followed by unidirectional glycol dimetacrylate glass-fiber Fibrante® (1022 N) and aramid fiber Kevlar® (966 N). These values represent 26%, 22% and 17% in relation to the control group (800 N), being non statistically significant difference observed among them. The group with &#x2205; 0,7mm orthodontic wire (871 N) had a resistance only 8% higher and similar of that of control group without reinforcement. Fracture analysis was conducted by the following scale: absence, partial, complete without separation, and complete with separation. Fracture modes observed on reinforced samples were considered more favorable, with types absent and partial seeing more frequently.
12

Avaliação da adaptação de estruturas em Y-TZP entre diferentes sistemas CAD/CAM / Adaptation assessment of Y-TZP frameworks between different CAD / CAM systems

Andreas Raphael Ribas Koren 04 March 2013 (has links)
OBJETIVOS: comparar dois sistemas CAD-CAM de diferentes gerações quanto ao grau de adaptação de infraestruturas estéticas de próteses fixas de três elementos para verificar se existe alguma evolução no quesito diminuição do gap marginal e se existe diferença de contração entre blocos de conformações diferentes que podem afetar diretamente a adaptação das mesmas. MATERIAL E MÉTODOS: para isso foi confeccionado um preparo de prótese fixa de três elementos em manequim odontológico simulando a ausência do elemento dental 25; posteriormente aos preparos foi reproduzido um modelo mestre em liga metálica Co-Cr para serem realizados os testes. O modelo mestre foi submetido a escaneamento em cada sistema comercial para a infraestrutura ser desenhada e fresada. Para serem confrontados, em cada sistema CAD/CAM foi confeccionado cinco infraestruturas em Y-TZP (n=5), sendo que no grupo CT1 foi utilizado um disco (ronde) com dimensões de 98x20 mm capaz de ser fresada até seis infraestruturas de uma só vez enquanto que no grupo CT2 cada infraestrutura foi confeccionada individualmente em um bloco com dimensões de 40x15x19 mm. Uma vez concluídas as infraestruturas, as mesmas foram submetidas a teste de adaptação com a técnica do dedal de silicone e posteriormente em cada preparo, tanto do molar quanto do pré-molar, foi retirada uma fatia de 2 mm de espessura em cada face (mesial, distal, lingual e vestibular) para se analisar a espessura de desadaptação na região de término através da análise de imagem (fotografia das fatias realizado por estereomicroscópio e medição com o software ImageJ). Os resultados foram submetidos aos testes de Normalidade e Homocedasticidade (p=0,05) e posteriormente analisados por ANOVA e Tukey (p=0,05). RESULTADOS: as medições foram divididas em dois grupos: 1. Adaptação geral ( medidas por face) e 2. Adaptação circunferencial (média das medidas das quatro faces). Em ambas as medições não houve diferenças estatisticamente significantes, permanecendo o gap marginal de ambos os materiais com resultados estatisticamente uniformes. CONCLUSÕES: ambos os sistemas CAD/CAM testados apresentaram resultados semelhantes e satisfatórios, dentro dos padrões clínicos aceitáveis e não houve diferença de contração de sinterização entre o disco (ronde) e o bloco. / OBJECTIVES: compare two CAD-CAM systems of different generations according to the adaptation level of three elements aesthetic FPD to discover if there are any changes in the item \"gap marginal decrease\" and if there is contraction differences between blocks of different conformations that may directly affect the adaptation. MATERIAL AND METHODS: it was made a FPD preparation (total crown preparation in each pillar tooth) in a dental mannequin, simulating the absence of the tooth 25; later was made a master template in Co-Cr alloy to be performed the tests, according to the mannequin preparations. The master model was subjected to scanning in each trading system to be designed the infrastructure and posteriorly milled. It was made five infrastructure in Y-TZP (n = 5) to be compared in every CAD / CAM system, and in the CT1 group was used a disc (ronde) with dimensions of 98x20 millimeters, where it can be milled up to six infrastructure of a once, while in the group CT2 each structure was fabricated into a single block with dimensions of 40x15x19 millimeters. After the infrastructure was milled, they were subjected to the adaptive technique of \"silicone replica\" and subsequently in each preparation (molar and premolar) was withdrawn from a 2 mm thickness slice on each side (mesial, distal, lingual and buccal) to analyze the mismatch thickness in the end region via image analysis (slices photography performed by a stereomicroscope and measured by the ImageJ software). The results were submited by Normality and Homoscedasticity test (p=0.05) and subsequently analyzed by ANOVA and Tukey test (p=0.05). RESULTS: the measurements were divided into two groups: 1. General adaptation (measures per side) and 2. Circumferential adaptation (average measure of the four faces). In both measurements there were no statistically significant differences, remaining both materials with statistically uniform marginal gap. CONCLUSIONS: both CAD / CAM systems tested showed similar and satisfactory results within the acceptable clinical standards and there was no sintering contraction difference between the disk (ronde) and block.
13

Avaliação da resistência à fratura de prótese parcial fixa provisória confeccionada sobre componentes do tipo UCLA em titânio - efeito de diversos reforços / Fracture resistance evaluation of provisional fixed partial denture made on titanium ucla components several reinforcements effect

Thania Grisel Rodriguez Almonte 31 May 2005 (has links)
As restaurações provisórias no tratamento reabilitador oral são de suma importância. Por isso é preocupante que os materiais utilizados para a execução das mesmas sejam críticos com relação à sua resistência e longevidade, principalmente, quando estas são executadas em tratamentos prolongados e/ou em espaços desdentados extensos. O objetivo deste trabalho foi avaliar em 4 grupos reforçados, compostos por 9 espécimes cada um, a resistência e o modo de fratura, de uma resina acrílica poli(metilmetacrilato) auto-polimerizável (Dencor® - Clássico®, São Paulo, SP, Brasil) utilizada para restaurações provisórias quando reforçada com fibras de vidro (Fibrante® e Interlig® - Angelus®, Londrina, PR, Brasil), fibras de aramida (Kevlar® - Du Pont®, USA) y fio ortodôntico &#x2205; 0, 7mm. E um grupo controle sem nenhum tipo de reforço, com a mesma quantidade de corpos de prova. A análise dos resultados (ANOVA, p < 0,05), para o teste de resistência, mostrou haver diferença estatística entre os grupos. O teste de Tukey encontrou que os grupos reforçados, aqueles que alcançaram maior média de resistência à fratura foram os que utilizaram a fibra de vidro trançada pré-impregnada com resina composta foto-polimerizável, Interlig® (1083 N); a fibra de vidro unidirecional préimpregnada com dimetacrilato de glicol, Fibrante® (1022 N) e a fibra de poli(aramida) unidirecional sem pré-impregnação, Kevlar® 29, aumentando em 26%, 22% e 17%, respectivamente, esta resistência em relação ao grupo controle (800 N), não havendo diferença estatística significante entre eles. O grupo reforçado com fio de aço com &#x2205; 0,7 mm (871 N) apareceu em seguida com uma resistência somente 8% maior e semelhante àquela apresentada pelo grupo controle sem reforço. A análise das fraturas concorreu com a elaboração de um novo sistema de classificação dividindo-as em quatro tipos: Ausente, Parcial, Total Não Separada e Total Separada. As fraturas dos espécimes reforçados foram consideradas mais favoráveis ocorrendo, predominantemente, os tipos Ausente e Parcial. / Provisional restorations are of ultimate importance in the oral rehabilitation treatment. Thus, clinicians have to bear in mind that materials used for their fabrication are critical due to its longevity and strength, when these are done for longterm therapy and/or large edentulous spaces. The aim of this work was to evaluate the flexural resistance and fracture mode of an auto-cure polymethylmetacrilate resin (Dencor® - Classico® , Sao Paulo, SP, Brasil) used for provisional restorations and reinforced with four materials. Samples were divided in four groups of nine each, as the following: glass fiber (Fibrante® and Interlig® Angelus®, Londrina, PR, Brasil), aramide fibers (Kevlar® Du Pont®, USA), and orthodontic wire &#x2205; 0,7mm. one group whitout reinforcement served as control. Data was submitted to statistical analysis with one-way ANOVA (p<.05) test. Results showed statistically significant difference among the groups. Tukeys test showed that glass-fiber Interlig® exhibited the greatest value of flexural strength (1083 N); followed by unidirectional glycol dimetacrylate glass-fiber Fibrante® (1022 N) and aramid fiber Kevlar® (966 N). These values represent 26%, 22% and 17% in relation to the control group (800 N), being non statistically significant difference observed among them. The group with &#x2205; 0,7mm orthodontic wire (871 N) had a resistance only 8% higher and similar of that of control group without reinforcement. Fracture analysis was conducted by the following scale: absence, partial, complete without separation, and complete with separation. Fracture modes observed on reinforced samples were considered more favorable, with types absent and partial seeing more frequently.

Page generated in 0.0485 seconds