• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 2
  • Tagged with
  • 5
  • 5
  • 5
  • 5
  • 5
  • 4
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Design and implementation of a thyristor controlled series capacitor for research laboratory application.

Mazibuko, Ronnie H. January 2003 (has links)
The power transfer capability of a transmission line is determined by the magnitude of the voltage at each end of the line, angle difference of these voltages and the impedance of the line. This impedance is mainly inductive. Traditionally, fixed series capacitor banks have been used for series compensation. However, due to instability problems associated with loading transmission line close to their thermal limits, researchers have looked at other alternatives to line compensation by static devices such as fixed series capacitors. Flexible AC Transmission Systems (FACTS) has allowed power utilities to use existing transmission line networks close to their thermal limits without compromising stability of the power system. A FACTS series compensator is capable of influencing the transmission of power in a transmission line by dynamic control of the series compensating reactance inserted in the line. There are several different devices under the FACTS family, however, in this thesis only the Thyristor-Controlled Series Capacitor (TCSC) was considered. A TCSC comprises a fixed capacitor in parallel with a thyristor-controlled reactor (TCR). By varying the firing angle ex:. of the thyristors, the TCSC can be made to act in variable inductive or capacitive reactance mode. The thesis' overall objective was to design a practical TCSC for use in a research laboratory for further research initiatives. This thesis looks at different issues that need to be considered when designing and rating a TCSC compensator. In particular, the thesis examines the effects of different sizes of TCSC components on the rating of the device, the effects of harmonics on the TCSC ratings, sizing of TCSC's variable reactance, and the response time of TCSC to a step change in the firing angle. A mathematical model of a TCSC in a single-machine infinite bus (SMIB) system was developed and subsequently used in the initial design of the TCSC. Studies that were done using mathematical model of the TCSC module confirmed the ability of the TCSC controller to dynamically control the capacitive compensating reactance in the transmission line. The thesis then describes the development of a laboratory-scale TCSC for research investigations. Measured results from the laboratory demonstrate the ability of the TCSC series compensator to provide rapid control of series reactance of a transmission line. A detailed mathematical model of the SMIB equipped with TCSC module was developed, using parameter values of the laboratory scale prototype, to investigate power oscillation damping. Time-domain simulation results are presented in this thesis to demonstrate its ability to damp power swings in an electrical network. / Thesis (M.Sc.Eng.)-University of Natal, Durban, 2003.
2

ANALYSIS, DESIGN, AND LABORATORY EVALUATION OF A DISTRIBUTED UNIFIED POWER FLOW CONTROLLER CONCEPT

Li, Qiang 01 January 2006 (has links)
A single-phase, buck-boost based, dual-output AC-DC converter is studied in this thesis. The converter has two DC outputs with opposite polarities, which share the same ground with the input power line. The power stage performance, including the input filter, is studied and procedure to select power components is given. The circuit model is analyzed to develop appropriate control. Zerocrossing distortion of the source input current is addressed and a solution is proposed. Experimental results are satisfactory in that a high power factor line current results for steady-state operation.
3

On the Dynamics and Statics of Power System Operation : Optimal Utilization of FACTS Devicesand Management of Wind Power Uncertainty

Nasri, Amin January 2014 (has links)
Nowadays, power systems are dealing with some new challenges raisedby the major changes that have been taken place since 80’s, e.g., deregu-lation in electricity markets, significant increase of electricity demands andmore recently large-scale integration of renewable energy resources such aswind power. Therefore, system operators must make some adjustments toaccommodate these changes into the future of power systems.One of the main challenges is maintaining the system stability since theextra stress caused by the above changes reduces the stability margin, andmay lead to rise of many undesirable phenomena. The other important chal-lenge is to cope with uncertainty and variability of renewable energy sourceswhich make power systems to become more stochastic in nature, and lesscontrollable.Flexible AC Transmission Systems (FACTS) have emerged as a solutionto help power systems with these new challenges. This thesis aims to ap-propriately utilize such devices in order to increase the transmission capacityand flexibility, improve the dynamic behavior of power systems and integratemore renewable energy into the system. To this end, the most appropriatelocations and settings of these controllable devices need to be determined.This thesis mainly looks at (i) rotor angle stability, i.e., small signal andtransient stability (ii) system operation under wind uncertainty. In the firstpart of this thesis, trajectory sensitivity analysis is used to determine themost suitable placement of FACTS devices for improving rotor angle sta-bility, while in the second part, optimal settings of such devices are foundto maximize the level of wind power integration. As a general conclusion,it was demonstrated that FACTS devices, installed in proper locations andtuned appropriately, are effective means to enhance the system stability andto handle wind uncertainty.The last objective of this thesis work is to propose an efficient solutionapproach based on Benders’ decomposition to solve a network-constrained acunit commitment problem in a wind-integrated power system. The numericalresults show validity, accuracy and efficiency of the proposed approach. / <p>The Doctoral Degrees issued upon completion of the programme are issued by Comillas Pontifical University, Delft University of Technology and KTH Royal Institute of Technology. The invested degrees are official in Spain, the Netherlands and Sweden, respectively.QC 20141028</p>
4

Performance Evaluation Of Distance Relays For FACTS Compensated Transmission Lines

Maturu, Suresh 03 1900 (has links) (PDF)
With limited enhancement or expansion of the transmission infrastructure, the contemporary power systems are operating under more stressed conditions. It becomes important to fully utilize the existing transmission system to supply load demand as much as possible, thus eliminating or reducing the need for new transmission investment. Flexible AC Transmission System (FACTS) technology provides an alternative to fully utilize the existing transmission lines as well as new and upgraded lines, by controlling power and also enhancing the power transfer capability of transmission lines. However, the implementation of FACTS controllers in the transmission system has introduced new power system dynamics that must be addressed in the area of power system protection, such as rapid changes in line impedance, power angle, line currents, transients introduced by the occurrence of fault and associated control action of the FACTS controller. Therefore, the performance of the protection system must be carefully analyzed in the presence of FACTS controllers. The thesis aims at evaluating the performance of distance relays when different types of FACTS controllers, in particular Voltage Source Converter (VSC) based FACTS controllers, are incorporated at the midpoint of the transmission system to achieve voltage profile improvement and power transfer capability. The detailed models of these controllers and their control strategies are described. The presence of FACTS controllers in the loop affects both steady state and transient components of voltage and current signals. The rapid response of FACTS controllers to different power system configurations significantly affects the apparent impedance seen by distance relays. The apparent impedance seen by distance relays would be different from that of the system without FACTS controller. Due to this, the distance relay may malfunction, resulting in unreliable operation of the power system during faults. Furthermore, the effect of FACTS controllers on distance relay operation depends on the type of FACTS controller used, the application for which it has been installed and its location in the power system. The distance relay is evaluated for different loading conditions and for various fault conditions. Simulation studies are carried out using PSCAD/EMTDC based transient simulation package.
5

Development Of Algorithms For Security Oriented Power System Operation

Yesuratnam, G 07 1900 (has links)
The objective of an Energy Control Center (ECC) is to ensure secure and economic operation of power system. The challenge to optimize power system operation, while maintaining system security and quality of power supply to customers, is increasing. Growing demand without matching expansion of generation and transmission facilities and more tightly interconnected power systems contribute to the increased complexity of system operation. Rising costs due to inflation and increased environmental concerns has made transmission, as well as generation systems to be operated closure to design limits, with smaller safety margins and hence greater exposure to unsatisfactory operating conditions following a disturbance. Investigations of recent blackouts indicate that the root cause of most of these major power system disturbances is voltage collapse. Information gathered and preliminary analysis, from the most recent blackout incident in North America on 14th August 2003, is pointing the finger on voltage instability due to some unexpected contingency. In this incident, reports indicate that approximately 50 million people were affected interruption from continuous supply for more than 15 hours. Most of the incidents are related to heavily stressed system where large amounts of real and reactive power are transported over long transmission lines while appropriate real and reactive power resources are not available to maintain normal system conditions. Hence, the problem of voltage stability and voltage collapse has become a major concern in power system planning and operation. Reliable operation of large scale electric power networks requires that system voltages and currents stay within design limits. Operation beyond those limits can lead to equipment failures and blackouts. In the last few decades, the problem of reactive power control for improving economy and security of power system operation has received much attention. Generally, the load bus voltages can be maintained within their permissible limits by reallocating reactive power generations in the system. This can be achieved by adjusting transformer taps, generator voltages, and switchable Ar sources. In addition, the system losses can be minimized via redistribution of reactive power in the system. Therefore, the problem of the reactive power dispatch can be optimized to improve the voltage profile and minimize the system losses as well. The Instability in power system could be relieved or at least minimized with the help of most recent developed devices called Flexible AC Transmission System (FACTS) controllers. The use of Flexible AC Transmission System (FACTS) controllers in power transmission system have led to many applications of these controllers not only to improve the stability of the existing power network resources but also provide operating flexibility to the power system. In the past, transmission systems were owned by regulated, vertically integrated utility companies. They have been designed and operated so that conditions in close proximity to security boundaries are not frequently encountered. However, in the new open access environment, operating conditions tend to be much closer to security boundaries, as transmission use is increasing in sudden and unpredictable directions. Transmission unbundling, coupled with other regulatory requirements, has made new transmission facility construction more difficult. In fact, there are numerous technical challenges emerging from the new market structure. There is an acute need for research work in the new market structure, especially in the areas of voltage security, reactive power support and congestion management. In the last few decades more attention was paid to optimal reactive power dispatch. Since the problem of reactive power optimization is non-linear in nature, nonlinear programming methods have been used to solve it. These methods work quite well for small power systems but may develop convergence problems as system size increases. Linear programming techniques with iterative schemes are certainly the most promising tools for solving these types of problems. The thesis presents efficient algorithms with different objectives for reactive power optimization. The approach adopted is an iterative scheme with successive power-flow analysis using decoupled technique, formulation and solution of the linear-programmingproblem with only upper-bound limits on the state variables. Further the thesispresents critical analysis of the three following objectives, Viz., •Minimization of the sum of the squares of the voltage deviations (Vdesired) •Minimization of sum of the squares of the voltage stability L indices (Vstability) •Minimization of real power losses (Ploss) Voltage stability problems normally occur in heavily stressed systems. While the disturbance leading to voltage collapse may be initiated by a variety of causes, the underlying problem is an inherent weakness in the power system. The factors contributing to voltage collapse are the generator reactive power /voltage control limits, load characteristics, characteristics of reactive compensation devices, and the action of the voltage control devices such as transformer On Load Tap Changers (OLTCs). Power system experiences abnormal operating conditions following a disturbance, and subsequently a reduction in the EHV level voltages at load centers will be reflected on the distribution system. The OLTCs of distribution transformers would restore distribution voltages. With each tap change operation, the MW and MVAR loading on the EHV lines would increase, thereby causing great voltage drops in EHV levels and increasing the losses. As a result, with each tap changing operation, the reactive output of generators throughout the system would increase gradually and the generators may hit their reactive power capability limits, causing voltage instability problems. Thus, the operation of certain OLTCs has a significant influence on voltage instability under some operating conditions. These transformers can be made manual to avoid possible voltage instability due to their operation during heavy load conditions. Tap blocking, based on local measurement of high voltage side of load tap changers, is a common practice of power utilities to prevent voltage collapse. The great advantage of this method is that it can be easily implemented, but does not guarantee voltage stability. So a proper approach for identification of critical OLTC s based on voltage stability criteria is essential to guide the operator in ECC, which has been proposed in this thesis. It discusses the effect of OLTCs with different objectives of reactive power dispatch and proposes a technique to identify critical OLTCs based on voltage stability criteria. The fast development of power electronics based on new and powerful semiconductor devices has led to innovative technologies, such as High Voltage DC transmission (HVDC) and Flexible AC Transmission System (FACTS), which can be applied in transmission and distribution systems. The technical and economicalBenefits of these technologies represent an alternative to the application in AC systems. Deregulation in the power industry and opening of the market for delivery of cheaper energy to the customers is creating additional requirements for the operation of power systems. HVDC and FACTS offer major advantages in meeting these requirements. .A method for co-ordinated optimum allocation of reactive power in AC/DC power systems by including FACTS controller UPFC, with an objective of minimization of the sum of the squares of the voltage deviations of all the load buses has been proposed in this thesis. The study results show that under contingency conditions, the presence of FACTS controllers has considerable impact on over all system voltage stability and also on power loss minimization.minimization of the sum of the squares of the voltage deviations of all the load buses has been proposed in this thesis. The study results show that under contingency conditions, the presence of FACTS controllers has considerable impact on over all system voltage stability and also on power loss minimization. As power systems grow in their size and interconnections, their complexity increases. For secure operation and control of power systems under normal and contingency conditions, it is essential to provide solutions in real time to the operator in ECC. For real time control of power systems, the conventional algorithmic software available in ECC are found to be inadequate as they are computationally very intensive and not organized to guide the operator during contingency conditions. Artificial Intelligence (AI) techniques such as, Expert systems, Neural Networks, Fuzzy systems are emerging decision support system tools which give fast, though approximate, but acceptable right solutions in real time as they mostly use symbolic processing with a minimum number of numeric computations. The solution thus obtained can be used as a guide by the operator in ECC for power system control. Optimum real and reactive power dispatch play an important role in the day-to-day operation of power systems. Existing conventional Optimal Power Flow (OPF) methods use all of the controls in solving the optimization problem. The operators can not move so many control devices within a reasonable time. In this context an algorithm using fuzzy-expert approach has been proposed in this thesis to curtail the number of control actions, in order to realize real time objectives in voltage/reactive power control. The technique is formulated using membership functions of linguistic variables such as voltage deviations at all the load buses and the voltage deviation sensitivity to control variables. Voltage deviations and controlling variables are translated into fuzzy set notations to formulate the relation between voltage deviations and controlling ability of controlling devices. Control variables considered are switchable VAR compensators, OLTC transformers and generator excitations. A fuzzy rule based system is formed to select the critical controllers, their movement direction and step size. Results show that the proposed approach is effective for improving voltage security to acceptable levels with fewer numbers of controllers. So, under emergency conditions the operator need not move all the controllers to different settings and the solution obtained is fast with significant speedups. Hence, the proposed method has the potential to be integrated for on-line implementation in energy management systems to achieve the goals of secure power system operation. In a deregulated electricity market, it may not be always possible to dispatch all of the contracted power transactions due to congestion of the transmission corridors. System operators try to manage congestion, which otherwise increases the cost of the electricity and also threatens the system security and stability. An approach for alleviation of network over loads in the day-to-day operation of power systems under deregulated environment is presented in this thesis. The control used for overload alleviation is real power generation rescheduling based on Relative Electrical Distance (RED) concept. The method estimates the relative location of load nodes with respect to the generator nodes. The contribution of each generator for a particular over loaded line is first identified , then based on RED concept the desired proportions of generations for the desired overload relieving is obtained, so that the system will have minimum transmission losses and more stability margins with respect to voltage profiles, bus angles and better transmission tariff. The results obtained reveal that the proposed method is not only effective for overload relieving but also reduces the system power loss and improves the voltage stability margin. The presented concepts are better suited for finding the utilization of resources generation/load and network by various players involved in the day-to-day operation of the system under normal and contingency conditions. This will help in finding the contribution by various players involved in the congestion management and the deviations can be used for proper tariff purposes. Suitable computer programs have been developed based on the algorithms presented in various chapters and thoroughly tested. Studies have been carried out on various equivalent systems of practical real life Indian power networks and also on some standard IEEE systems under simulated conditions. Results obtained on a modified IEEE 30 bus system, IEEE 39 bus New England system and four Indian power networks of EHV 24 bus real life equivalent power network, an equivalent of 36 bus EHV Indian western grid, Uttar Pradesh 96 bus AC/DC system and 205 Bus real life interconnected grid system of Indian southern region are presented for illustration purposes.

Page generated in 0.106 seconds