• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 135
  • 65
  • 52
  • 7
  • 4
  • 4
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 298
  • 116
  • 113
  • 106
  • 101
  • 95
  • 93
  • 75
  • 71
  • 51
  • 42
  • 41
  • 39
  • 39
  • 34
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
121

Distribuição dinâmica de sobrecargas no pé durante a corrida em diferentes pisos / In-shoe dynamic foot loading during running in different running surfaces

Vitor Daniel Tessutti 15 December 2008 (has links)
Associado ao aumento do número de praticantes de corrida, houve o aumento proporcional no número de lesões em corredores. Esta ocorrência pode estar relacionada ao volume semanal de treino, aos desvios posturais em membros inferiores, ao tipo de calçado e ao piso selecionados para a prática da corrida, e até mesmo à experiência prévia na modalidade. A superfície de corrida pode ser considerada como um fator extrínseco relacionado a estas lesões e tem sido pesquisada atualmente mas com resultados controversos ainda quanto a sua influência nas sobrecargas do aparelho locomotor. Já, o tempo de experiência na corrida também pode ser considerado um importante fator extrínseco que foi até agora superficialmente estudado. O objetivo do presente trabalho foi investigar a influência de quatro diferentes superfícies de corrida (asfalto, concreto, grama natural e borracha) e da experiência prévia na prática da corrida (até 2 anos, entre 2 e 5 anos e acima de 5 anos) na distribuição da pressão plantar. Foram realizados 3 experimentos para responder aos objetivos do presente trabalho, cada um com sua casuística particular: experimento 1 (n=44) e 2 (n=57) para responder a influência do tipo de piso nas cargas plantares; e experimento 3 (n=126) para responder a influência da experiência da corrida nas pressões plantares. Em todos eles, corredores recreacionais adultos (entre 18 e 40 anos) correram nos 4 pisos estudados a uma velocidade de 12km/h em um trecho de 40 metros onde se investigou a pressão plantar por meio de palmilhas capacitivas (Pedar X, Novel) colocadas dentro de um calçado esportivo padronizado. Para investigar o efeito da experiência na corrida, as medições foram realizadas somente no asfalto. Os dois primeiros experimentos responderam que a grama atenuou em até 16% o pico de pressão plantar nas regiões laterais comparada aos demais pisos, inclusive à borracha cujo comportamento foi similar ao do asfalto e do concreto, superfícies consideradas rígidas. Este resultado pode ser atribuído a estratégias de movimento mais flexíveis das extremidades distais, particularmente do complexo tornozelo/pé, na superfície mais complacente, o qual não foi observado nas superfícies mais rígidas (asfalto e concreto), assim como, surpreendentemente, no piso de borracha. O terceiro experimento respondeu que corredores com menos do que dois anos de experiência na corrida apresentam maiores picos de pressão de cerca de 10% em retropé e antepé em relação aos mais experientes (acima de 5 anos). A atenuação de cargas plantares observadas em corredores mais experientes pode estar relacionada à adoção de um padrão motor mais eficiente que resultaria em uma maior habilidade de acomodação da extremidade distal às cargas. Como conclusão, os resultados destes experimentos demonstram que tempos de prática menores que dois anos e correr no asfalto, concreto ou borracha promovem maiores sobrecargas plantares. A combinação tempo de experiência acima de 5 anos e correr na grama é a condição que mais promove atenuação de sobrecargas plantares / There has been an increase in the number of injuries proportional to the increase of the number of runner. This occurrence can be related to the weekly distance of trainings, lower extremities postural alignment, type of the selected footwear and the running, and the previous experience in running. The running surface can be considered as a extrinsic factor related to these injuries and has been currently studied. Although the results concerning its influence in the overloads of the locomotor system are controversial. The time of running experience can also be considered an important extrinsic factor that is still superficially studied so far. The objective of the present work was to investigate the influence of four different running surfaces (asphalt, concrete, natural gram and rubber) and of the previous running experience (up to 2 years, between 2 and 5 years and up to 5 years) in the plantar pressure distribution. Three experiments had been carried out to answer to the aims of the present work, each one with its particular casuistic: experiment 1 (n=44) and 2 (n=57) to answer the influence of the type of surface in plantar loads; and experiment 3 (n=126) to answer the influence of the running experience in the plantar pressures. Adults recreational runners (between 18 and 40 yrs old) run in the four studied surfaces over 40 meters in a speed of 12km/h where the plantar pressure was investigated by in-shoe capacitive insoles (Pedar X, Novel) placed inside an standardized sports footwear. To investigate the effect of the running experience, the measurements had only been carried out in asphalt. The two first experiments answered that the grass attenuated up to 16% the peak pressure in the lateral regions of the foot compared to the other surfaces, including the rubber whose behavior was similar to the asphalt and the concrete, considered rigid surfaces. This result can be attributed the more flexible movement strategies of the distal extremities, particularly of the foot/ankle complex, in the more compliant surface, which was not observed in the most rigid surfaces (asphalt and concrete), as well as, surprisingly, in the rubber surface. The third experiment answered that runners with less than two years of experience in the running practice presented greaters peak pressures of about 10% in the medial rearfoot and forefoot compared to the most experienced runners (up to 5 years). The plantar loads attenuation observed in the more experienced runners can be related to the adoption of a more efficient motor pattern that would result in a higher ability to accommodate loads in the lower extremity. In summary, the results of these experiments demonstrated that running practice experience of less than two years and running in asphalt, concrete or rubber promotes higher plantar loads. The combination time of experience up to 5 years and running in the grass is the condition that promotes more attenuation of plantar pressures
122

Tecnologia lítica no Médio Paranapanema: um estudo de caso das ocupações da transação holoceno inicial-médio do Sítio Brito (Sarutaiá/SP). / Lithic technology in the middle Paranapanema: a case study of the Early/Middle Holocene ocuppations of Brito site (Sarutaiá/SP)

Mendes, Diego Teixeira 16 April 2014 (has links)
O presente trabalho é referente ao estudo das indústrias líticas do sítio Brito, localizado na margem direita do rio Paranapanema, no Estado de São Paulo. Os materiais estudados estão associados a datações recuadas a transição Holoceno Inicial/Médio, entre, aproximadamente, 8.000 BP e 6.500 BP. O nosso primeiro objetivo concerne à caracterização tecnológica das indústrias líticas a partir de uma abordagem centrada no conceito de cadeia operatória visando reconstituir os processos técnicos e as estratégias de uso das matérias primas que geraram a variabilidade artefatual observada. O segundo objetivo trata da verificação, por meio da análise da distribuição vertical e horizontal dos vestígios, da integridade de solos de ocupação identificados durante a escavação. Propomos que as indústrias líticas mais antigas do sítio Brito estão distribuídas em um nível arqueológico caracterizado por um palimpsesto de ocupações. / The present dissertation refers to the study of the lithic assemblages from the Brito site, located at the right bank of the Paranapanema river, in the state of São Paulo. The materials that were studied are associated to dates that go back to the transition between the initial and the middle Holocene, approximately 8,000 to 6,500 BP. Our first objective concerns the technological characterization of the lithic assemblages from an approach based on the concept of operation sequence (chaîne opératoire), with the aim of reconstituting the technical processes and the strategies of usage of raw material that generated the observed artifact variability. The second objective was to verify, by means of analyzing the vertical and horizontal distribution of the lithic materials, the integrity of the occupational floors identified during the fieldwork. We suggest that the oldest lithic assemblages of the Brito site are distributed over an archeological level characterized by a palimpsest of occupations.
123

Sensibilidade a vibrações de pavimentos com lajes alveolares / Vibration sensitivity of hollow core slabs floor

Marcos, Lara Kawai 03 June 2015 (has links)
As lajes alveolares são elementos eficientes do ponto de vista estrutural, pois os alvéolos permitem significativa redução de peso próprio sem comprometer a resistência e a rigidez. Além disso, é muito comum nesses elementos o uso de protensão, o que permite que estas lajes consigam vencer grandes vãos e se tornem uma solução competitiva. No entanto, para certas combinações de vãos, espessura da laje, ligações e propriedades dos materiais, esse sistema estrutural pode ser suscetível a vibrações excessivas. Há poucos estudos sobre a sensibilidade a vibrações destes elementos cuja aplicação é comum em situações de especial interesse como escritórios, nos quais as vibrações podem causar significativos incômodos aos usuários. Este trabalho visa contribuir para o melhor entendimento sobre a sensibilidade a vibrações de pavimentos com lajes sujeitas à ação dinâmica de atividades humanas. Além disso, pretende-se avaliar o comportamento dinâmico dos pavimentos com lajes alveolares em diferentes situações de interesse: painéis isolados, unidos por chaves de cisalhamento e após a concretagem da capa. Foi realizado um estudo experimental em um pavimento de um edifício comercial em estrutura de concreto pré-moldado nas três situações distintas da construção e foram obtidas as frequências naturais, modos de vibração e amortecimento para cada etapa, bem como uma análise do conforto ao usuário, a partir dos limites previstos em normas nacionais e internacionais. Foi também realizada uma análise numérica, na qual, além da determinação teórica de modos de vibração e frequências naturais, foram determinados os níveis de vibração gerados pelo caminhar de pessoas. As frequências naturais obtidas numericamente apresentaram diferença média de 11% com relação às experimentais. A diferença média dos picos de aceleração numéricos e experimentais foi de 9%. Tais resultados possibilitaram validar o modelo numérico proposto. A análise de conforto do pavimento indicou que a norma brasileira ANBT NBR 6118 (2014) não apresenta prescrições suficientes para se evitar vibrações excessivas em pavimentos com lajes alveolares protendidos. Os resultados permitiram concluir que as chaves de cisalhamento e a capa estrutural foram determinantes para garantir níveis aceitáveis de vibração no pavimento analisado. / Hollow core slabs are very efficient structural members, since their voids allow a significant reduction of self-weight, without jeopardizing the strength and stiffness. Moreover, prestressed concrete is commonly employed in this type of structure, allowing their use in large spans. Consequently, this is a very competitive solution. However, for certain combination of spans, slab thickness, connections and materials properties, this structural system can be susceptible to excessive vibrations. There is a lack of studies on vibration sensitivity of these elements, which are commonly applicable in situations of special interest, as offices, in which vibration can cause significant annoyance to users. This work aims to contribute to a better understanding about vibration sensitivity of hollow core slabs floors. Moreover, we intend to evaluate the dynamic behavior of hollow core slabs in different situations of interest: single panels, panels joined by shear keys and after completion of concrete topping. This analysis involves the determination of natural frequencies, mode shapes, damping ratios and vibrational levels generated by walking. An experimental study was carried out on a floor of a precast concrete structure of a commercial building in three different stages of construction. In this study, the natural frequencies, mode shapes and damping for each step were obtained, as well as an analysis of comfort, based on limits defined by national and international standards. A numerical analysis was also performed in which the vibration modes and natural frequencies were theoretically determined and the vibration levels generated by walking were estimated. The natural frequencies obtained numerically showed an average difference of 11% compared to experimental. The average difference between the numerical and experimental peak acceleration was 9%. These results allowed the validation of the numerical model proposed. The comfort analysis of the floor indicated that the Brazilian standard ANBT NBR 6118 (2014) does not provide sufficient provisions to avoid excessive vibrations in floors with prestressed hollow core slabs. The results showed that the shear keys and the structural topping were crucial to ensure acceptable levels of vibration.
124

Avaliação das propriedades de concretos reforçados com fibras de aço para utilização em pisos industriais / Evaluation of steel fiber reinforced concrete for industrial floors

Guimarães, Diego January 2015 (has links)
Os pisos industriais são elementos que estão presentes em muitas obras da construção civil. Devido a isso, estudos devem ser procedidos para melhorar seu desempenho. Concretos reforçados com fibras metálicas são alternativas para a produção de pisos, pois as fibras melhoram o comportamento do concreto transformando-o de um material quase-frágil em um material com comportamento pseudo-ductil. Diversas manifestações patológicas vêm sendo constatadas em pisos, como fissuras, e o emprego destas fibras visa minimizar estas deficiências. Assim, nesta pesquisa, foi estudado o traço 1: 2,5: 3,1 a/c 0,55, com adição de três teores diferentes de fibras: 0,25%; 0,35% e 0,60%, em volume de concreto, e dois fatores de forma FF/65 e FF/80. Para avaliar características do concreto foram realizados ensaios de flexão a quatro pontos, flexão a três pontos, módulo de elasticidade e resistência à compressão axial. A partir destes ensaios pode-se verificar o comportamento de cada teor em relação: à tenacidade, às variações na carga de pico, à capacidade de manter a resistência residual pós-ruptura e à abertura da fissura. Também foram avaliadas as diferenças do comportamento em relação à moldagem dos CPs, devido ao fato que foram moldados CPs cilíndricos convencionais e extraídos de blocos. Verificou-se que a inserção de fibras não causa significativas alterações na resistência à compressão axial e também no módulo de elasticidade. Quando a análise é realizada para o tipo de moldagem verificou-se que os CPs cilíndricos convencionais obtiveram melhor desempenho, em comparação aos extraídos. Na avaliação dos ensaios de flexão observou-se que o teor exerce maior influência no desempenho se comparado com a mudança no fator de forma. padrão de fissuração nas vigas foi o esperado para teores abaixo do volume crítico. Verificou-se uma menor variabilidade dos resultados de flexão a três pontos em relação ao ensaio de flexão a quatro pontos. Constatou-se um aumento da energia de fratura com o aumento do teor de fibras. Com as propriedades estimadas experimentalmente foi dimensionado um piso industrial para uma aplicação específica, ressaltando que o teor de 0,35% seria a melhor alternativa. Concluindo que nesta pesquisa a variação no FF não causou impactos no desempenho final ressaltando que o teor de 0,35% seria a melhor alternativa, para o dimensionamento. / Industrial floors are elements that are present in many works of construction. Because of this, studies should be proceeded to improve their performance. Concrete reinforced with steel fibers are alternatives for the production of floors, because the fibers improve the concrete behavior making it a quasi-brittle material in a material with pseudo-ductile behavior. Several pathological manifestations have been observed in floors, such as cracks, and the use of these fibers is to minimize these deficiencies. Thus, in this research, we studied the trace 1: 2.5: 3.1 a / c 0.55, with addition of three different levels of fiber: 0.25%; 0.35% and 0.60% in volume of concrete, and two form factors FF / 65 and FF / 80. To evaluate specific characteristics of flexure tests were conducted at four points, the three points bending, modulus of elasticity and resistance to axial compression. From these tests can verify the behavior of each content regarding: the tenacity, to changes in peak load, the ability to maintain the post-break residual strength and the opening of the crack. They were also evaluated behavioral differences in relation to the molding of CPs due to the fact that were shaped conventional cylindrical CPs and extracted blocks. It was found that the fiber insertion does not cause significant changes in compressive strength and also the modulus of elasticity. When the analysis is performed for the type of molding it found that conventional cylindrical CPs performed better in comparison to extracted. In the evaluation of bending tests it was observed that the content has the most influence on performance compared with the change in form factor. The pattern of cracks on the beams was expected to levels below the critical volume. There was less variation of bending results at three points over the flexure test at four points. It was found an increased fracture energy with increased fiber content. With the properties estimated experimentally has been designed an industrial floor for a specific application, pointing out that the 0.35% level would be the best alternative. Concluding that this research variation in FF caused no impact on final performance pointing out that the 0.35% level would be the best alternative for the design.
125

住宅樓層價差之探討-以台北市為例 / A Study of The Different Prices for Housing Floors

張曦方, Chang, Si Fung Unknown Date (has links)
住宅價格主要乃是由平面價差與立體價差組合,並受供、需面的交互作用競價而成,對於位在同一塊基地上的各層樓而言,亦會因不同的空間屬性組合而產生不同的價格水準;而以往的住宅研究報告多偏重於探討有關總體面與平面區位條件的差異性對價格形成的影響,卻鮮少有人針對住宅立體屬性的差異對價格的影響做進一步的深入探討。因此本研究以臺北市地區為研究範圍,探討住宅樓層間的立體價格差異是否存在?影響樓層價差現象產生的因素為何?樓層價差的產生受供給面亦或是需求面的影響較大?   由於一般業者對於樓層的定價原則與消費者購屋樓層選擇的主客觀考量因素不同,因此可藉由市場實際樓層價格分佈狀況反應出市場呈現何種導向,並可為市場樓層價差之形成提供一合理之解釋。   茲將本研究之主要研究成果與結論略述如下:   一、供給面:     1.供給面訂定樓層價差主要依據乃是根據既有的區域市場供給面平均價差水準,再以產品的個體差異性(注重建物各層的空間居住條件差異程度)採評點加總法做價格上的調整,對於樓層價差的訂價方式缺乏需求面資料變動的預測與分析。   二、需求面(問卷調查分析結果):     1.地區別因素與樓層間的價格差異皆不是決定居民選購樓層的主要考重因素,可見得台北市居民對於樓層的選購重視的是居住環境品質,而非價差因素。     2.居民屬性之年齡別、家庭成員組成不同皆會影響樓層之選擇。     3.最喜愛居住樓層所占百分比依次為三樓(22.2%)、五樓(12.6%)和一樓(12.2%),二樓亦佔了百分之11.8%,其餘樓層之喜愛人數則隨著高度的增加而減少。     4.最不喜愛樓層具有一般性,集中於一、二、四樓最多。     5.喜愛樓層與選購之重視因素關係而言,低、中、高樓層之訴求明顯不同,相近樓層間之空間屬性需求則相近。     6.由消費者樓層偏好人數問卷調查結果得知,大多數的居民仍偏向於居住較低樓層,中間樓層次之,高樓層喜居人數最少,由此可知,需求面考量之安全性、可及性因素,重於舒適性因子之需求;供給面考量重心則有所不同,舒適性因子重於安全性、可及性因子之需求。   三、市場實證分析:     1.民國80年代初期,經檢定結果得知,樓層變數對於樓層價差形成其有顯著的影響,可見得樓層間的價差現象確實存在。     2.影響樓層價差產生的因素主要可分為居民屬性與建物屬性兩類,建物屬性則為安全性、可及性與舒適性的差異影響較顯著。     3.就樓層間的價格分佈來說,五層樓以下的樓層間價格高低關係變動幅度較大,無一定的價差模式可循,五層樓以上的住宅,樓層間的價差關係較明確,具有樓層越高,價格越高的相同趨勢,且中間樓層之價差較大,高樓層之價差幅度較小,相近樓層間的價差較平緩。     4.個別地區樓層間的實際價格差距雖然因地區與業者主觀的定價模式的不同而會有所差異,但基本上,樓層的價格高低分佈和樓層的高度有著一定的關係。     5.消費者的偏好改變,對於個別樓層的價格會有所影響,但由於消費者的議價空間有限,因此整體而言,市場價格仍是反應供給面訂定樓層價差的定價原則與方式。   由此可知,臺灣住宅市場本就呈現強烈的供給導向,因此樓層價差自然較符合供給面之定價原則,需求面的真實偏好對於價差的形成雖亦具有影響力,但影響效果有限。
126

Novel Compliant Flooring Systems from Head to Toes: Influences on Early Compensatory Balance Reactions in Retirement-Home Dwelling Adults and on Impact Dynamics during Simulated Head Impacts

Wright, Alexander David 16 June 2011 (has links)
The overall goal of my research was to advance our understanding of the potential for novel compliant flooring systems to reduce the risk for fall-related injuries in older adults, including fall-related traumatic brain injury (TBI). This entailed an assessment of how these floors affect the competing demands of fall-related TBI – impact severity attenuation in concert with minimal concomitant impairments to balance control and postural stability. Two studies are included as part of this thesis. The first study used a mechanical drop tower to assess the effects of four traditional flooring systems and six novel compliant flooring conditions on the impact dynamics of a surrogate headform during the impact phase of simulated ‘worst- case’ head impacts. The second study entailed an assessment of the effect of two traditional and three novel compliant floors on the initial phase of the compensatory balance reactions of older adult men and women living in a residential-care facility environment following an externally induced perturbation using a tether-release paradigm. Overall, this thesis demonstrates that novel compliant floors substantially attenuate the forces and accelerations applied to the head during simulated worst- case impacts when compared to traditional flooring surfaces such as vinyl and carpet with underpadding. These benefits are achieved without compromising indices of balance control, supported by the finding that parameters characterizing early compensatory balance reactions were unaffected by the novel compliant floors tested. This work supports the introduction of pilot installations of novel compliant flooring systems into environments with high incidences of falls to test their effectiveness at reducing fall-related injuries in clinical settings.
127

Novel Compliant Flooring Systems from Head to Toes: Influences on Early Compensatory Balance Reactions in Retirement-Home Dwelling Adults and on Impact Dynamics during Simulated Head Impacts

Wright, Alexander David 16 June 2011 (has links)
The overall goal of my research was to advance our understanding of the potential for novel compliant flooring systems to reduce the risk for fall-related injuries in older adults, including fall-related traumatic brain injury (TBI). This entailed an assessment of how these floors affect the competing demands of fall-related TBI – impact severity attenuation in concert with minimal concomitant impairments to balance control and postural stability. Two studies are included as part of this thesis. The first study used a mechanical drop tower to assess the effects of four traditional flooring systems and six novel compliant flooring conditions on the impact dynamics of a surrogate headform during the impact phase of simulated ‘worst- case’ head impacts. The second study entailed an assessment of the effect of two traditional and three novel compliant floors on the initial phase of the compensatory balance reactions of older adult men and women living in a residential-care facility environment following an externally induced perturbation using a tether-release paradigm. Overall, this thesis demonstrates that novel compliant floors substantially attenuate the forces and accelerations applied to the head during simulated worst- case impacts when compared to traditional flooring surfaces such as vinyl and carpet with underpadding. These benefits are achieved without compromising indices of balance control, supported by the finding that parameters characterizing early compensatory balance reactions were unaffected by the novel compliant floors tested. This work supports the introduction of pilot installations of novel compliant flooring systems into environments with high incidences of falls to test their effectiveness at reducing fall-related injuries in clinical settings.
128

Comportement mécanique de planchers diaphragmes en bois : semi-rigidité et résistance pour une situation sismique / Mechanical behavior of timber floor diaphragms : stiffness and strength under seismic situation

Fuentes, Sebastian 19 June 2013 (has links)
Pour les structures en bois comme pour les autres techniques de construction, les planchers jouent un rôle important dans le comportement global d’un bâtiment soumis à une sollicitation sismique. En plus de la reprise des efforts verticaux, ces planchers assurent le transfert des efforts horizontaux vers les murs de contreventement (fonction diaphragme). Pour cette fonction, le plancher peut être assimilé à une poutre courte disposée horizontalement et supportée par plusieurs appuis semi-rigides (murs de contreventement). En conséquence, la distribution des efforts sur les murs de contreventement est directement liée au rapport entre leurs raideurs et celle du plancher dans son plan.Les planchers en bois traditionnels sont généralement composés par une poutraison (des solives, des entretoises et des poutres de chaînage) et une surface plane composée d’une juxtaposition de panneaux. La connexion panneaux-poutraison est généralement réalisée par des clous. Le dimensionnement de ces planchers est souvent piloté par les charges verticales et les caractéristiques mécaniques dans le plan sont rarement contrôlées.Le comportement mécanique des planchers diaphragmes en bois est peu étudié dans la littérature. La présente thèse aborde ce comportement en s’appuyant sur trois approches : analytique, numérique (M.E.F.) et expérimentale. L’approche analytique s’inspire de celle utilisée par les codes de calcul sismique nord-américains. La modélisation numérique prend en compte la configuration géométrique réelle des diaphragmes ainsi que les effets non-linéaires matériels et géométriques. Deux types de modèles numériques sont proposés : « détaillé » et « simplifié ». Le modèle détaillé, utilisant des éléments de poutres et de coques, permet d’étudier la distribution des contraintes internes au sein du plancher. Le modèle simplifié, moins coûteux, s’appuie sur des éléments poutres et barres. Il permet de réaliser des analyses de sensibilité et il peut être utilisé dans des analyses de structures avec géométries complexes.Une campagne expérimentale est conduite sur des planchers en bois. Deux planchers (2,4x7,2m2), avec et sans entretoises, sont testés en flexion dans leur plan. Une instrumentation riche composée de capteurs de déplacement, d’inclinomètres et d’un système de mesure sans contact, sont utilisés pour suivre le comportement de ces planchers aux niveaux global et local. Les observations expérimentales montrent un comportement fortement non-linéaire avec une influence importante des entretoises sur la raideur et la résistance. La rupture des panneaux est due à la flexion à mi portée ou à la compression près des angles en contact. La comparaison avec les résultats expérimentaux a permis de valider les modèles numériques développés. Ces modèles révèlent une forte participation de la connexion panneaux-poutraison aux comportements mécaniques des planchers aux niveaux global et local.Le modèle numérique simplifié est utilisé pour mener une étude de sensibilité des planchers avec trémies. Ainsi, treize configurations de planchers sont analysées en vue d’identifier les positionnements les plus défavorables des trémies. Par ailleurs, l’application du modèle analytique montre qu’il représente correctement la phase linéaire du comportement des planchers qui est un paramètre utilisable dans les analyses à l’état limite de service. Les résultats numériques et expérimentaux obtenus constituent une bonne base pour étendre le domaine d’application du modèle analytique. / In timber structures as other, floors play an important role in the overall behaviour of a building subjected to seismic loading. In addition to the vertical forces, these floors transfer horizontal forces to the shear walls (diaphragm function). For this function, the floor can be considered as a short beam placed horizontally and supported by semi-rigid supports (shear walls). Therefore, the force distribution on the shear walls is directly related to the in-plane stiffness ratio between floors and shear walls.Traditional wooden floors are usually composed by joists framing (joist, struts, chords beams) and a surface made by juxtaposed panels. The panel-joist framing connection is usually made by nails. Size of the floors elements is often driven by the vertical loads, thus mechanical properties in the plane are rarely checked.The in-plane behaviour of timber floor is poorly studied in the literature. This thesis studies this behaviour using three approaches: analytical, numerical (FEM) and experimental. The analytical approach is based on that used in North American codes of seismic design. Numerical models take into account the actual geometry of the timber diaphragms and nonlinear effects (material and geometric). Two types of numerical models are proposed: "detailed" and "simplified". The detailed model, based on beams and shell elements, allows studying the distribution of internal stresses in the floor. The simplified model uses beams and bar elements. It allows carrying out sensitivity analysis and can be used to study complex geometries of floors.An experimental campaign is conducted on timber floors. Two floors (2,4 x7,2m2), in blocked or unblocked configuration, are tested in bending in their plane. Displacement transducers, inclinometers and a camera measuring system are used for monitoring the behaviour of floors at global and local levels. The experimental observations show a highly nonlinear behaviour with a significant influence of struts on the stiffness and strength. Panels failure due to bending and compression in the corners were observed. The comparison between experimental and numerical results allows validating the numerical models. These models show a significant participation of the panels-joist framing connection on the global and local mechanical behaviour of floors.The simplified model is used to conduct a sensitivity analysis of floors with hoppers. Thirteen floors configurations are analyzed to identify the most unfavourable configurations of hoppers position. Furthermore, the analytical model represents well the linear phase of floors behaviour. The numerical and experimental results obtained provide a good basis to expand the scope of the analytical model. / Tanto en las estructuras de madera como en otras técnicas de construcción, las losas juegan un importante rol en el comportamiento global de un edificio sometido a una solicitación sísmica. Además de las cargas verticales, las losas deben transmitir las cargas horizontales hacia los muros de corte (función diafragma). En esta función, la losa puede ser tratada como una viga corta puesta horizontalmente y apoyada sobre soportes semi-rígidos (muros de corte). En consecuencia, la distribución de fuerzas entre los distintos muros de corte es determinada por la relación de rigidez entre estos muros y la losa.Las losas tradicionales de madera son generalmente compuestas por un envigado (vigas transversales, canes o separadores, vigas periféricas) y una superficie construida con paneles yuxtapuestos. La conexión entre los paneles y el envigado es generalmente realizada con clavos. El dimensionamiento de estos elementos es habitualmente determinado por las cargas verticales, de esta manera las propiedades mecánicas en el plano de estas losas, son raramente controladas.El comportamiento mecánico de los diafragmas de madera ha sido poco estudiado en la literatura. Esta tesis aborda este comportamiento a partir de tres enfoques: analítico, numérico (Elementos Finitos) y experimental. El método analítico considerado se basa en las ecuaciones propuestas por los códigos de diseño sísmico norteamericanos. La modelización numérica tiene en cuenta la configuración geométrica real de las losas y los efectos no-lineares de origen material y geométrico. Dos tipos de modelos numéricos son propuestos: "detallado" y "simplificado". El modelo detallado, es construido a partir de elementos finitos de tipo vigas y planos. Este modelo es utilizado principalmente para estudiar la distribución de esfuerzos internos en las losas. El modelo simplificado, construido a partir de elementos de vigas y barras, es utilizado para conducir análisis de sensibilidad.Un estudio experimental sobre losas de madera es presentado. Dos losas (2,4 x7, 2m2) con y sin separadores son testeadas en flexión en su plano. Un sistema de instrumentación compuesto por transductores de desplazamiento, inclinómetros y videocámaras, fueron utilizados para monitorear el comportamiento global y local de las losas. Las observaciones experimentales muestran un comportamiento altamente no-lineal con una fuerte influencia de los separadores sobre la rigidez y resistencia de la estructura. Los modos de ruptura observados corresponden a la ruptura de paneles en flexión y a la compresión local debido a transmisión de esfuerzos por contacto. La comparación de resultados experimentales y numéricos permite validar los modelos propuestos. Estos modelos muestran una fuerte participación de la conexión paneles-envigado sobre el comportamiento mecánico global y local de las losas.El modelo numérico simplificado es utilizado para llevar a cabo un análisis de sensibilidad de losas con aberturas de escalera. Trece configuraciones de losas son analizadas para identificar la posición de abertura más desfavorable. Por otra parte, el modelo analítico representa correctamente el comportamiento de las losas en fase lineal. Los resultados numéricos y experimentales obtenidos proporcionan una buena base para ampliar el dominio de aplicación de este modelo analítico.
129

Contribuição ao estudo do desgaste superficial por abrasão em concretos empregados em pisos / Contribution to the study of surface wear by abrasion in concrete used in floors

Silva, Cristina Vitorino da January 2011 (has links)
O desgaste superficial constitui uma das manifestações patológicas mais recorrentes em pisos de concreto. A presença de tal manifestação patológica, proveniente do processo abrasivo, é muito preocupante, uma vez que implica em altos custos para reparar ou substituir este concreto danificado. Portanto, a realização de estudos que buscam avaliar a influência do proporcionamento e tipo de alguns materiais que constituem o traço de concreto, comumente empregado em pisos, é considerada extremamente relevante, no intuito de reduzir a tendência de desgaste dos compósitos. Neste particular, foram avaliados alguns fatores, como o consumo de água (175 l/m³; 190 l/m³; 205 l/m³), o teor de substituição de sílica ativa (0%; 5%; 10%), o teor de adição de microfibras de polipropileno (0 g/m³; 600 g/m³) e o tipo de cimento (CP IV; CP V-ARI). Os ensaios adotados para esta avaliação foram o de resistência à compressão uniaxial, resistência à tração na flexão, dureza superficial por esclerometria, exsudação e resistência à abrasão. Os resultados encontrados mostraram uma influência estatística significativa do tipo de cimento em todas as propriedades avaliadas, sendo que o cimento CP V-ARI apresentou melhor desempenho em comparação ao cimento CP IV, considerando uma mesma relação a/agl (0,53). O fator consumo de água, mantendo-se constante a relação a/agl, mostrou influência significativa na resistência à tração na flexão e na resistência à abrasão dos concretos, e, além disso, foi possível verificar um comportamento semelhante para ambas as propriedades com relação a este parâmetro de controle. Quanto ao teor de substituição de sílica ativa, observa-se que este fator promoveu efeito significativo nas propriedades mecânicas, o que era esperado, na dureza superficial e na exsudação; entretanto, não se verificou influência no desgaste por abrasão dos compósitos cimentícios. Já a adição das microfibras de polipropileno diminuiu significativamente a dureza superficial por esclerometria, sem alterar as demais propriedades analisadas. Os resultados verificados para o desgaste mostraram uma importante relação com as propriedades mecânicas dos concretos. O processo de acabamento como forma de tratamento superficial parece ser efetivo no controle do desgaste por abrasão, uma vez que pode ter minimizado o efeito da exsudação na superfície dos compósitos cimentícios. O consumo de água de 190 l/m³ mostrou ser o teor mais adequado para os materiais e concretos empregados nesta pesquisa. / Surface wear is one of the most frequent pathologies in concrete floors. The presence of such pathological manifestation from the abrasive process is very disturbing, since it implies high costs to repair or replace the damaged concrete. Therefore, studies that seek to evaluate the influence of the proportioning and type of some materials that constitute the mixture proportions of concrete, commonly used on floors, are considered extremely relevant, in order to reduce the tendency of surface wear of composites. In this study, factors such as water consumption (175 l/m³, 190 l/m³, 205 l/m³), replacement content of silica fume (0 %, 5 %, 10 %), addition content of polypropylene fibers (0 g/m³, 600 g/m³) and cement type (CP IV; CP V-ARI) were evaluated. The tests used for this assessment were compressive strength, flexural tensile strength, surface hardness by rebound hammer, bleeding and abrasion resistance. The results showed a significant statistic influence of the cement type on all the properties evaluated, with the cement CP V-ARI presenting a better performance compared to cement CP IV, considering the same w/b ratio (0.53). The water consumption factor, maintaining a constant w/b ratio, showed significant influence on the flexural tensile strength and abrasion resistance of concrete, and, in addition, we could observe a similar behavior for both properties with respect to this parameter of control. Regarding the replacement content of silica fume, it is observed that this factor promoted significant effect on the mechanical properties, which was expected, on the surface hardness and bleeding; however, there was no influence on the abrasion of the cementitious composites. The addition of polypropylene microfibers significantly decrease the surface hardness by rebound hammer, without altering any other property evaluated. The results verified for the wear showed an important relationship with the mechanical properties of concrete. The finishing process as a form of surface treatment seems to be effective in controlling the abrasive wear, since it may have minimized the effect of bleeding on the surface of cementitious composites. The water consumption of 190 l/m³ showed to be the most appropriate content for the materials and concrete used in this research.
130

Avaliação das propriedades de concretos reforçados com fibras de aço para utilização em pisos industriais / Evaluation of steel fiber reinforced concrete for industrial floors

Guimarães, Diego January 2015 (has links)
Os pisos industriais são elementos que estão presentes em muitas obras da construção civil. Devido a isso, estudos devem ser procedidos para melhorar seu desempenho. Concretos reforçados com fibras metálicas são alternativas para a produção de pisos, pois as fibras melhoram o comportamento do concreto transformando-o de um material quase-frágil em um material com comportamento pseudo-ductil. Diversas manifestações patológicas vêm sendo constatadas em pisos, como fissuras, e o emprego destas fibras visa minimizar estas deficiências. Assim, nesta pesquisa, foi estudado o traço 1: 2,5: 3,1 a/c 0,55, com adição de três teores diferentes de fibras: 0,25%; 0,35% e 0,60%, em volume de concreto, e dois fatores de forma FF/65 e FF/80. Para avaliar características do concreto foram realizados ensaios de flexão a quatro pontos, flexão a três pontos, módulo de elasticidade e resistência à compressão axial. A partir destes ensaios pode-se verificar o comportamento de cada teor em relação: à tenacidade, às variações na carga de pico, à capacidade de manter a resistência residual pós-ruptura e à abertura da fissura. Também foram avaliadas as diferenças do comportamento em relação à moldagem dos CPs, devido ao fato que foram moldados CPs cilíndricos convencionais e extraídos de blocos. Verificou-se que a inserção de fibras não causa significativas alterações na resistência à compressão axial e também no módulo de elasticidade. Quando a análise é realizada para o tipo de moldagem verificou-se que os CPs cilíndricos convencionais obtiveram melhor desempenho, em comparação aos extraídos. Na avaliação dos ensaios de flexão observou-se que o teor exerce maior influência no desempenho se comparado com a mudança no fator de forma. padrão de fissuração nas vigas foi o esperado para teores abaixo do volume crítico. Verificou-se uma menor variabilidade dos resultados de flexão a três pontos em relação ao ensaio de flexão a quatro pontos. Constatou-se um aumento da energia de fratura com o aumento do teor de fibras. Com as propriedades estimadas experimentalmente foi dimensionado um piso industrial para uma aplicação específica, ressaltando que o teor de 0,35% seria a melhor alternativa. Concluindo que nesta pesquisa a variação no FF não causou impactos no desempenho final ressaltando que o teor de 0,35% seria a melhor alternativa, para o dimensionamento. / Industrial floors are elements that are present in many works of construction. Because of this, studies should be proceeded to improve their performance. Concrete reinforced with steel fibers are alternatives for the production of floors, because the fibers improve the concrete behavior making it a quasi-brittle material in a material with pseudo-ductile behavior. Several pathological manifestations have been observed in floors, such as cracks, and the use of these fibers is to minimize these deficiencies. Thus, in this research, we studied the trace 1: 2.5: 3.1 a / c 0.55, with addition of three different levels of fiber: 0.25%; 0.35% and 0.60% in volume of concrete, and two form factors FF / 65 and FF / 80. To evaluate specific characteristics of flexure tests were conducted at four points, the three points bending, modulus of elasticity and resistance to axial compression. From these tests can verify the behavior of each content regarding: the tenacity, to changes in peak load, the ability to maintain the post-break residual strength and the opening of the crack. They were also evaluated behavioral differences in relation to the molding of CPs due to the fact that were shaped conventional cylindrical CPs and extracted blocks. It was found that the fiber insertion does not cause significant changes in compressive strength and also the modulus of elasticity. When the analysis is performed for the type of molding it found that conventional cylindrical CPs performed better in comparison to extracted. In the evaluation of bending tests it was observed that the content has the most influence on performance compared with the change in form factor. The pattern of cracks on the beams was expected to levels below the critical volume. There was less variation of bending results at three points over the flexure test at four points. It was found an increased fracture energy with increased fiber content. With the properties estimated experimentally has been designed an industrial floor for a specific application, pointing out that the 0.35% level would be the best alternative. Concluding that this research variation in FF caused no impact on final performance pointing out that the 0.35% level would be the best alternative for the design.

Page generated in 0.0554 seconds