• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 9
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 20
  • 20
  • 6
  • 6
  • 6
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Detekce průtoku pomocí optických interferenčních metod / Flow detection using optical intereference methods

Hoštáková, Nina January 2015 (has links)
The thesis deals with LSCI (Laser Speckle Contrast Imaging), an optical method utilizing laser speckle contrast for the estimation of blood flow changes. LSCI is non-invasive and technically not demanding approach, capabilities of which have not yet been fully exploited. The literature review part contains detailed description of the operating principle, imaging techniques, potential for medical applications with considering the limiting factors. The main aim of the thesis is to design and construct a complete LSCI system including appropriate phantoms able to simulate blood flow through the tissue. Imaging algorithms for the obtained data evaluation were implemented in Matlab® development enviroment. Finally, the created system was tested using different acquisition parameters as well as varying the image processing schemes. The resulting qualitative flow images were subsequently discussed and confronted with the theoretical assumptions.
12

From 2D to 3D cardiovascular ultrafast ultrasound imaging : new insights in shear wave elastography and blood flow imaging / De l'imagerie échographique ultrarapide cardiovasculaire 2D vers le 3D : nouvelles perspectives en élastographie par des ondes de cisaillement et de l'imagerie du flux sanguin

Correia, Mafalda Filipa Rodrigues 22 November 2016 (has links)
Ces travaux de thèse portent sur le développement de nouvelles modalités d’imagerie cardiovasculaire basé sur l’utilisation de l'imagerie ultrarapide 2D et 3D. Les modalités d’imagerie développées dans cette thèse appartiennent au domaine de de l’élastographie par onde de cisaillement et de l'imagerie Doppler des flux sanguins.Dans un premier temps, la technique de l’élastographie par onde de cisaillement du myocarde a été développée pour les applications cliniques. Une approche d'imagerie non-linéaire a été utilisée pour améliorer l’estimation de vitesse des ondes de cisaillement (ou la rigidité des tissus cardiaques) de manière non invasive et localisée. La validation de cette nouvelle approche de « l’imagerie par sommation cohérente harmonique ultrarapide » a été réalisée in vitro et la faisabilité in vivo a été testée chez l’humain. Dans un second temps, nous avons utilisé cette technique sur des patients lors de deux essais cliniques, chacun ciblant une population différente (adultes et enfants). Nous avons étudié la possibilité d’évaluer quantitativement la rigidité des tissus cardiaques par élastographie chez des volontaires sains, ainsi que chez des malades souffrant de cardiomyopathie hypertrophique. Les résultats ont montré que l’élastographie pourrait devenir un outil d'imagerie pertinent et robuste pour évaluer la rigidité du muscle cardiaque en pratique clinique. Par ailleurs, nous avons également développé une nouvelle approche appelée « imagerie de tenseur élastique 3-D » pour mesurer quantitativement les propriétés élastiques des tissus anisotropes comme le myocarde. Ces techniques ont été testées in vitro sur des modèles de de gels isotropes transverses. La faisabilité in vivo de l’élastographie par onde cisaillement à trois-dimensions a été également évaluée sur un muscle squelettique humain.D'autre part, nous avons développé une toute nouvelle modalité d’imagerie ultrasonore des flux coronariens basée sur l’imagerie Doppler ultrarapide. Cette technique nous a permis d'imager la circulation coronarienne avec une sensibilité élevée, grâce notamment au développement d’un nouveau filtre adaptatif permettant de supprimer le signal du myocarde en mouvement, basé sur la décomposition en valeurs singulières (SVD). Des expériences à thorax ouvert chez le porc ont permis d'évaluer et de valider notre technique et les résultats ont montré que la circulation coronaire intramurale, peut être évaluée sur des vaisseaux de diamètres allant jusqu’à 100 µm. La faisabilité sur l’homme a été démontrée chez l’enfant en imagerie clinique transthoracique.Enfin, nous avons développé une nouvelle approche d’imagerie des flux sanguins, « l’imagerie ultrarapide 3-D des flux», une nouvelle technique d'imagerie quantitative des flux. Nous avons démontré que cette technique permet d’évaluer le débit volumétrique artériel directement en un seul battement cardiaque, indépendamment de l'utilisateur. Cette technique a été mise en place à l'aide d'une sonde matricielle 2-D et d’un prototype d’échographe ultrarapide 3-D développé au sein du laboratoire. Nous avons évalué et validé notre technique in vitro sur des fantômes artériels, et la faisabilité in vivo a été démontrée sur des artères carotides humaines. / This thesis was focused on the development of novel cardiovascular imaging applications based on 2-D and 3-D ultrafast ultrasound imaging. More specifically, new technical and clinical developments of myocardial shear wave elastography and ultrafast blood flow imaging are presented in this manuscript.At first, myocardial shear wave elastography was developed for transthoracic imaging and improved by a non-linear imaging approach to non-invasively and locally assess shear wave velocity measurements, and consequently tissue stiffness in the context of cardiac imaging. This novel imaging approach (Ultrafast Harmonic Coherent Compounding) was tested and validated in-vitro and the in vivo feasibility was performed in humans for biomechanical evaluation of the cardiac muscle wall, the myocardium. Then, we have translated shear wave elastography to the clinical practice within two clinical trials, each one with a different population (adults and children). In both clinical trials, we have studied the capability of shear wave elastography to assess quantitatively myocardial stiffness in healthy volunteers and in patients suffering from hypertrophic cardiomyopathy. The results in the adult population indicated that shear wave elastography may become an effective imaging tool to assess cardiac muscle stiffness in clinical practice and help the characterization of hypertrophic cardiomyopathy. Likewise, we have also translated Shear Wave Elastography into four-dimensions and we have developed a new approach to map tissue elastic anisotropy in 3-D. 3-D Elastic Tensor Imaging allowed us to estimate quantitatively in a single acquisition the elastic properties of fibrous tissues. This technique was tested and validated in vitro in transverse isotropic models. The in-vivo feasibility of 3D elastic tensor imaging was also assessed in a human skeletal muscle.In parallel, we have developed a novel imaging technique for the non-invasive and non-radiative imaging of coronary circulation using ultrafast Doppler. This approach allowed us to image blood flow of the coronary circulation with high sensitivity. A new adaptive filter based on the singular value decomposition was used to remove the clutter signal of moving tissues. Open-chest swine experiments allowed to evaluate and validate this technique and results have shown that intramural coronary circulation, with diameters up to 100 µm, could be assessed. The in-vivo transthoracic feasibility was also demonstrated in humans in pediatric cardiology.Finally, we have developed a novel imaging modality to map quantitatively the blood flow in 3-D: 3-D ultrafast ultrasound flow imaging. We demonstrated that 3-D ultrafast ultrasound flow imaging can assess non-invasively, user-independently and directly volumetric flow rates in large arteries within a single heartbeat. We have evaluated and validated our technique in vitro in arterial phantoms using a 2-D matrix-array probe and a customized, programmable research 3-D ultrafast ultrasound system, and the in-vivo feasibility was demonstrated in human carotid arteries.
13

Investigation of Laser Speckle Contrast Imaging's Sensitivity to Flow

Young, Anthony M. 30 July 2018 (has links)
No description available.
14

Untersuchung bildgebender Ultraschallmesstechnik für instationäre Strömungsvorgänge in der Magnetohydrodynamik

Nauber, Richard 16 April 2019 (has links)
Bei einer Reihe bedeutsamer industrieller Prozesse, wie dem Stahl-Strangguss oder der Kristallzucht für die Photovoltaik, ist die Strömung flüssiger Metalle oder Halbleiter entscheidend für den Energieaufwand bei der Herstellung und die Qualität des Endproduktes. Eine gezielte, berührungslose Einwirkung von Lorentzkräften auf die heißen Schmelzen kann dabei die Ressourceneffizienz eines Prozesses signifikant steigern. Die komplexe Interaktion von elektrisch leitfähigen Fluiden und magnetischen Wechselfeldern wird dazu in der Magnetohydrodynamik (MHD) durch Experimente im Labormaßstab an niedrigschmelzenden Metallen untersucht. Die dabei auftretenden instationären, dreidimensionalen Strömungsfelder erfordern eine nicht-invasive, bildgebende Strömungsmesstechnik für opake Fluide mit hoher Orts- und Zeitauflösung, welche derzeitig nicht für die MHD zur Verfügung steht. Im Rahmen dieser Arbeit soll mit den Mitteln der Elektrotechnik eine für MHD-Modellexperimente geeignete Messtechnik basierend auf dem Ultraschall-Doppler-Prinzip geschaffen werden. Dabei wird der Ansatz verfolgt, die Komplexität eines Messsystems vom mechanischen Aufbau hin zur Rechentechnik zu verlagern, um durch die dort in jüngster Zeit verfügbaren Ressourcen neuartige Signalverarbeitungsmethoden und eine höhere Flexibilität zu ermöglichen. Mit dem Ultrasound Array Doppler Velocimeter (UADV) wurde ein flexibles Messsystem für MHD-Modellexperimente geschaffen, welches eine mehrkomponentige Mehrebenenmessung durch Sensordatenfusion von bis zu neun linearen Wandlerarrays im kombinierten Zeit- und Ortsmultiplex erreicht. Die Signalverarbeitung ist durch eine auf einem Field Programmable Gate Array implementierte Datenkompression onlinefähig. Sie reicht trotz geringer rechentechnischer Komplexität bis auf Faktor 3 an die fundamentale Grenze der Messunsicherheit, die Cramér-Rao-Schranke, heran. Das UADV wurde über ein Kalibrierexperiment mit interferometrischer Referenzmessung auf die SI-Einheiten zurückgeführt. Das UADV wurde an einer magnetfeldgetriebenen Strömung in einem kubischen Gefäß angewandt. Numerische Simulationen sagen dort nicht-deterministisch einsetzende Instabilitäten im Übergangsbereich des laminaren zum turbulenten Strömungsregimes vorher. Durch eine simultane Zweiebenenmessung mit hoher örtlicher (3 ... 5 mm) und zeitlicher Auflösung (Bildrate 11,2 Hz) bei gleichzeitig langer Aufnahmedauer (> 1000 s) konnten die Instabilitäten erstmals experimentell charakterisiert werden. Eine Hauptkomponentenanalyse identifizierte ein gekoppeltes Paar von Strömungsmoden, welche eine spontan anfachende harmonische Oszillation mit der Frequenz f = 0,072 Hz beschreiben und durch komplexe Wirbel gekennzeichnet sind. Die Analyse der Messunsicherheit für das gegebene Experiment ergab, dass diese mit σ v,rel = 13,9 % hauptsächlich durch das räumliche Auflösungsvermögen bestimmt wird. Das Schallfeld ist bei ultraschallbasierten Messverfahren ausschlaggebend für die Eigenschaften der Bildgebung. Mit dem Phased Array Doppler Velocimeter (PAUDV) wurde ein modulares Messsystem mit adaptiven Schallfeld aufgebaut, wobei durch digitale Strahlformung die örtliche und zeitliche Auflösung signifikant erhöht werden kann. Eine aktive Kontrolle des Schallfeldes ermöglicht zudem die Messung durch Objekte mit komplexen, unbekannten Ausbreitungseigenschaften. Mit dem Time Reversal Virtual Array (TRVA) wird dabei eine effiziente Methode zur Bildgebung vorgestellt und auf die Strömungsmessung durch einen Multimode-Wellenleiter angewandt. Damit kann die Beschränkung bildgebender Ultraschallmesstechnik hinsichtlich der Betriebstemperatur der Wandler umgangen und heiße Schmelzen industrieller und technischer Prozesse für nichtinvasive In-Prozess-Bildgebung zugänglich gemacht werden. / In many important industrial processes, such as continuous steel casting or crystal growth for photovoltaic silicon, the flow of liquid metals or semiconductors determines the energy consumption of the process and the quality of the product. Influencing the hot melts contactlessly through Lorentz forces for a targeted flow control can significantly improve the resource-efficiency of a process. The complex interaction of electrically conductive fluids and alternating magnetic fields is investigated in the field of magnetohydrodynamics (MHD) through laboratory-scale experiments in low melting metals. The emerging instationary, three-dimensional flows require a temporally and spatially high-resolved non-invasive flow imaging system, which currently is not available for MHD research. In this work, a flow instrumentation for MHD experiments based on the ultrasound Doppler principle is created through means of electrical engineering. The general approach is to shift the complexity of a system from mechanics over electronics to an algorithmic implementation in order to exploit the recent computational advances, enabling novel signal processing methods and increasing the flexibility. The ultrasound array Doppler velocimeter (UADV) has been created as a flexible instrumentation system for MHD experiments. It supports multicomponent, multiplane velocity measurements through sensor fusion of up to nine linear transducer arrays with spatiotemporal multiplexing. An online signal processing is realized through data compression on a field-programmable gate array (FPGA). It achieves an uncertainty as low as a factor 3 of the Cramér-Rao lower bound despite a low computational complexity of the algorithm. The UADV has been applied to a magnetically-driven flow in a cubic vessel. Numerical simulations predicted a non-deterministic instability in the transitory region between laminar and turbulent flow regimes. A simultaneous two-dimensional two-component flow measurement with high spatial (3 ... 5 mm) and temporal resolution (frame rate 11,2 Hz) over long durations (> 1000 s) allowed to characterize those instabilities experimentally for the first time. A principal component analysis identified a pair of coupled modes with a complex vortex structure that performs a spontaneously onsetting oscillation at f = 0,072 Hz. The measurement uncertainty for the experiment has been evaluated to be σ v,rel = 13,9 % and is primarily caused by the spatial resolution of the system. The properties of ultrasound-based imaging are primarily determined by the sound field. The phased array Doppler velocimeter (PAUDV) has been developed as a modular flow instrumentation system with an adaptive sound field, which allows to increase the spatial and temporal resolution. Furthermore, an active control of the sound field enables measurements despite a complex, unknown sound propagation. A method to image through strong aberrations efficiently has been proposed with the time reversal virtual array (TRVA). It has been applied to flow imaging through a multimode waveguide, thus allowing to circumvent the limitation of common ultrasound imaging systems regarding their maximum operating temperature. This paves the way for in-process flow imaging of hot, opaque liquids in technical and industrial processes.
15

Mechanistic approaches towards understanding particle formation in biopharmaceutical formations : the role of sufactant type and level on protein conformational stability, as assessed by calorimetry, and on protein size stability as assessed by dynamic light scattering, micro flow imaging and HIAC

Vaidilaite-Pretorius, Agita January 2013 (has links)
Control and analysis of protein aggregation is an increasing challenge to biopharmaceutical research and development. Therefore it is important to understand the interactions, causes and analysis of particles in order to control protein aggregation to enable successful biopharmaceutical formulations. This work investigates the role of different non-ionic surfactants on protein conformational stability, as assessed by HSDSC, and on protein size stability as assessed by Dynamic Light Scattering (DLS), HIAC and MFI. BSA and IgG2 were used as model proteins. Thermal unfolding experiments indicated a very weak surfactant-immunoglobulin IgG2 interaction, compared to much stronger interactions for the BSA surfactant systems. The DLS results showed that BSA and IgG2 with different surfactants and concentration produced different levels of particle size growth. The heat treatment and aging of samples in the presence of Tween 20, Tween 80, Brij 35 and Pluronic F-68 surfactants led to an increase in the populations of larger particles for BSA samples, whereas IgG2 systems did not notably aggregate under storage conditions MFI was shown to be more sensitive than HIAC technique for measuring sub-visible particles in protein surfactant systems. Heat treatment and storage stress showed a significant effect on BSA and IgG2 protein sub-visible particle size stability. This work has demonstrated that both proteins with different Tween 20, Tween 80, Brij 35 and Pluronic F-68 concentrations, have different level of conformational and size stability. Also aging samples and heating stress bears the potential to generate particles, but this depends on surfactant type. Poor predictive correlations between the analytical methods were determined.
16

Development and validation of innovative ultrasound flow imaging methods / Développement et validation de nouvelles méthodes d'imagerie du flux par ultrasons

Lenge, Matteo 17 March 2015 (has links)
L'échographie est largement utilisée pour l'imagerie du flux sanguin pour ses nombreux avantages tels que son inocuité, son cout réduit, sa facilité d'utilisation et ses performances. Cette thèse a pour objectif de proposer de nouvelles méthodes ultrasonores d'imagerie du flux sanguin. Après une étude bibliographique, plusieurs approches ont été étudiées en détail jusqu'à leur implémentation sur l'échographe de recherche ULA-OP développé au sein du laboratoire et ont été validées en laboratoire et en clinique. La transmission d'ondes planes a été proposée pour améliorer la technique d'imagerie utilisant les oscillations transverses. Des champs de pression ultrasonores présentant des oscillations transverses sont générés dans de larges régions et exploités pour l'estimation vectorielle du flux sanguin à une haute cadence d'imagerie. Des cartes du flux sanguin sont obtenues grâce à une technique s'appuyant sur la transmission d'ondes planes couplées à un nouvel algorithme d'estimation de la vitesse dans le domaine fréquentiel. Les méthodes vectorielles implémentées en temps réel dans le ULA-OP ont été comparées à la méthode Doppler classique lors d'une étude clinique. Les résultats ont montré le bénéfice des méthodes vectorielles en termes de précision et de répétabilité. La nouvelle méthode proposée a démontré sa grande précision ainsi que son gain en termes de temps de calcul aussi bien en simulations qu'en acquisitions en laboratoire ou lors d'essais in vivo. Une solution logicielle temps réel implémentée sur une carte GPU a été proposée et testée afin de réduire encore le temps de calcul et permettre l'emploi de la méthode en clinique / Ultrasound is widely used for blood flow imaging because of the considerable advantages for the clinician, in terms of performance, costs, portability, and ease of use, and for the patient, in terms of safety and rapid checkup. The undesired limitations of conventional methods (1-D estimations and low frame-rate) are widely overtaken by new vector approaches that offer detailed descriptions of the flow for a more accurate diagnosis of cardiovascular system diseases. This PhD project concerns the development of novel methods for blood flow imaging. After studying the state-of-the-art in the field, a few approaches have been examined in depth up to their experimental validation, both in technical and clinical environments, on a powerful ultrasound research platform (ULA-OP). Real-time novel vector methods implemented on ULA-OP were compared to standard Doppler methods in a clinical study. The results attest the benefits of the vector methods in terms of accuracy and repeatability. Plane-wave transmissions were exploited to improve the transverse oscillation imaging method. Double oscillating fields were produced in large regions and exploited for the vectorial description of blood flow at high frame rates. Blood flow maps were obtained by plane waves coupled to a novel velocity estimation algorithm operating in the frequency domain. The new method was demonstrated capable of high accuracy and reduced computational load by simulations and experiments (also in vivo). The investigation of blood flow inside the common carotid artery has revealed the hemodynamic details with unprecedented quality. A software solution implemented on a graphic processing unit (GPU) board was suggested and tested to reduce the computational time and support the clinical employment of the method
17

Improvement of the retention-fromation relationship using three-component retention aid systems

Svedberg, Anna January 2012 (has links)
QC 20120530
18

Mechanistic approaches towards understanding particle formation in biopharmaceutical formations. The role of sufactant type and level on protein conformational stability, as assessed by calorimetry, and on protein size stability as assessed by dynamic light scattering, micro flow imaging and HIAC

Vaidilaite-Pretorius, Agita January 2013 (has links)
Control and analysis of protein aggregation is an increasing challenge to biopharmaceutical research and development. Therefore it is important to understand the interactions, causes and analysis of particles in order to control protein aggregation to enable successful biopharmaceutical formulations. This work investigates the role of different non-ionic surfactants on protein conformational stability, as assessed by HSDSC, and on protein size stability as assessed by Dynamic Light Scattering (DLS), HIAC and MFI. BSA and IgG2 were used as model proteins. Thermal unfolding experiments indicated a very weak surfactant-immunoglobulin IgG2 interaction, compared to much stronger interactions for the BSA surfactant systems. The DLS results showed that BSA and IgG2 with different surfactants and concentration produced different levels of particle size growth. The heat treatment and aging of samples in the presence of Tween 20, Tween 80, Brij 35 and Pluronic F-68 surfactants led to an increase in the populations of larger particles for BSA samples, whereas IgG2 systems did not notably aggregate under storage conditions MFI was shown to be more sensitive than HIAC technique for measuring sub-visible particles in protein surfactant systems. Heat treatment and storage stress showed a significant effect on BSA and IgG2 protein sub-visible particle size stability. This work has demonstrated that both proteins with different Tween 20, Tween 80, Brij 35 and Pluronic F-68 concentrations, have different level of conformational and size stability. Also aging samples and heating stress bears the potential to generate particles, but this depends on surfactant type. Poor predictive correlations between the analytical methods were determined.
19

Ultraschallmessverfahren für komplexe Suspensionsströmungen in kleinen Geometrien: Untersuchung am Beispiel der Zink-Luft-Flussbatterie

Kupsch, Christian 26 November 2020 (has links)
Der zunehmende Einsatz regenerativer Energiequellen erfordert die Nutzung von Energiezwischenspeichern, die umweltfreundlich, günstig und skalierbar sein sollten. Die Zink-Luft-Flussbatterie (ZLFB) kann perspektivisch diese Anforderungen erfüllen, wobei zur Bereitstellung der gespeicherten Energie eine Suspension aus Zinkpartikeln in einem gelierten Elektrolyt durch eine elektrochemische Zelle gepumpt wird. Um die Strömungsstruktur der ZLFB auszulegen und Fehlfunktionen zu vermeiden, ist ein grundlegendes Verständnis der Rheologie der Zinksuspension notwendig. Außerdem kann über die Einstellung einer geeigneten Strömung die bei der Entladung erreichte elektrische Leistungsdichte gesteigert werden. Bereits die Flüssigphase der Zinksuspension weist eine komplexe nicht-Newtonsche Rheologie auf, welche durch die Zugabe der Partikel komplexer wird. Für das grundlegende Verständnis der Rheologie werden daher Modellexperimente durchgeführt, wobei in dieser Arbeit ein L-förmiger Kanal mit Strömungsaufweitung untersucht wurde, um die komplexen strömungsmechanischen Eigenschaften der Zinksuspension abzubilden. Zur Erfassung des Strömungsfeldes ist eine Ortsauflösung von 1 … 2 mm in einem Messbereich von 20 × 15 mm2 erforderlich. Ultraschall ist prinzipiell geeignet, um das Strömungsfeld in der opaken Suspension zu erfassen, wobei die wesentliche Herausforderung in den starken Wellenfrontverzerrungen besteht, welche durch die Zinkpartikel eingebracht werden. Es konnte gezeigt werden, dass die Ultrasound Imaging Velocimetry (UIV) robuster gegenüber diesen Störungen ist, als die Ultraschall-Doppler-Velozimetrie (UDV). Die UIV wurde daher mittels Geschwindigkeitsnormal an die messtechnischen Randbedingungen der Zinksuspension angepasst und charakterisiert. Bei einer Ortsauflösung von 1,6 mm wurde eine Gesamtmessunsicherheit von 2,5 % axial und 4,1 % lateral zur Schallausbreitungsrichtung erreicht. Das im Modellexperiment gemessene Strömungsfeld weist eine Totzone an der Strömungsumlenkung auf, deren Auftreten durch eine von der Scherhistorie abhängige Viskosität erklärt werden kann. Dieser Effekt wird als Thixotropie bezeichnet. Durch die In-situ-Messung der Strömung in einer aktiven ZLFB kann eine Korrelation von Strömung und elektrischer Leistung erfolgen und die erzielte Leistungsdichte perspektivisch durch eine Anpassung der Strömung gesteigert werden. Bei der Messung im 2,6 mm hohen Anodenspalt muss aufgrund der komplexen Rheologie der Suspension und der daraus resultierenden hohen Geschwindigkeitsgradienten eine Ortsauflösung von unter 100 µm bei gleichzeitig kleiner Ultraschallfrequenz realisiert werden, da der Ultraschall für hohe Frequenzen nicht in die Zinksuspension eindringt. Um dieses Ziel zu erreichen, wurde die Super Resolution Ultrasound Particle Tracking Velocimetry (SRPTV) genutzt, welche Ortsauflösungen unterhalb des Beugungslimits ermöglicht. Einzelne nichtlineare Streupartikel werden mittels Harmonic Imaging isoliert abgebildet und verfolgt, wobei die durch die Zinkpartikel eingebrachten Wellenfrontstörungen durch einen kohärenzgewichteten Strahlformer kompensiert werden. Es wurde eine Ortsauflösung von 67 µm axial und 30 µm lateral zur Schallausbreitungsrichtung bei einer Anregungswellenlänge von 330 µm erreicht. Trotz der stark streuenden Zinksuspension, konnte so eine Messung in der aktiven ZLFB mit einer maximalen Messunsicherheit von 12,5 % durchgeführt werden. Dabei wurde eine Wandgleitgeschwindigkeit von 3 mm s−1 bei einer maximalen Geschwindigkeit von etwa 8 mm s−1 festgestellt. Die SRPTV kann darüber hinaus in anderen technischen Prozessen eingesetzt werden, in denen Suspensionsströmungen in kleinen Geometrien auftreten.:Symbolverzeichnis xiii Abkürzungsverzeichnis xv 1 Einleitung 1 1.1 Motivation und Zielstellung 1 1.2 Stand der Technik 4 1.3 Lösungsansatz und Struktur der Arbeit 8 2 Theoretische Grundlagen 11 2.1 Grundlagen der Schallausbreitung 11 2.1.1 Schallausbreitung in homogenen Medien 11 2.1.2 Schallausbreitung in inhomogenen Medien 13 2.2 Ultraschall Bildgebung 14 2.2.1 Phased-Array-Prinzip 15 2.2.2 Plane wave imaging 16 2.2.3 Grenzen der Schallfeldfokussierung 16 2.3 Messung von Strömungsfeldern 17 2.3.1 Ultraschall-Doppler-Velozimetrie 18 2.3.2 Ultrasound Imaging Velocimetry 19 2.3.3 Ultrasound Particle Tracking Velocimetry 19 2.4 Nichtlineare akustische Effekte 20 2.4.1 Beschreibung von Linearität 20 2.4.2 Interaktion von nichtlinearen Streupartikeln und Schallwelle 20 2.4.3 Harmonic Imaging 21 3 Experimentelle Grundlagen 25 3.1 Charakterisierung der Zinksuspension 25 3.1.1 Zusammensetzung der Zinksuspension 25 3.1.2 Bestimmung von Dämpfung und Schallgeschwindigkeit 26 3.1.3 Bestimmung der spezifischen akustischen Impedanz 29 3.2 Messtechnik 30 3.2.1 Ultraschallforschungsplattform: Phased Array Ultrasound Dopp- ler Velocimeter 30 3.2.2 Ultraschallwandler 32 4 Verfahren zur Strömungsmessung im Modellexperiment 37 4.1 Experimenteller Aufbau 37 4.2 Untersuchung geeigneter Verfahren zur Messung von Strömungsfel- dern in der Zinksuspension 38 4.3 Optimierung der Signalverarbeitung und Charakterisierung der Messei- genschaften 44 4.3.1 Geschwindigkeitsnormal 44 4.3.2 Optimierung der Messsystemparameter 45 4.3.3 Charakterisierung der Messeigenschaften 48 4.3.4 Validierung 49 4.4 Messung der Suspensionsströmung im Modellexperiment 55 4.4.1 Messergebnisse 55 4.4.2 Vergleich von Simulation und Messung 58 4.5 Fazit 61 5 Verfahren zur In-situ-Strömungsmessung in einer Zink-Luft-Flussbatterie 63 5.1 Experimenteller Aufbau 63 5.2 Strömungsmessung unterhalb des Beugungslimits - Super Resolution Ultrasound Particle Tracking Velocimetry (SRPTV) 65 5.2.1 Nutzung nichtlinearer Streupartikel 68 5.2.2 Trennung von linearem und nichtlinearem Signalanteil 72 5.2.3 Strahlformung mit Kompensation der Streuung 76 5.2.4 Particle Tracking 80 5.3 Charakterisierung der Messeigenschaften 81 5.3.1 Vorgehen zur Charakterisierung der Messeigenschaften 82 5.3.2 Untersuchung der Positionsunsicherheit 83 5.3.3 Untersuchung der Geschwindigkeitsunsicherheit 92 5.4 Messung an einer aktiven Zink-Luft-Flussbatterie 95 5.4.1 Aufbau und Durchführung 95 5.4.2 Messergebnisse 97 5.4.3 Vergleich von Simulation und Messung 97 5.5 Fazit 102 6 Zusammenfassung und Ausblick 103 6.1 Erkenntnisse und Fortschritt 103 6.1.1 Ultrasound Imaging Velocimetry 103 6.1.2 Super Resolution Ultrasound Particle Tracking Velocimetry 104 6.1.3 Fazit 106 6.2 Ausblick und weiterführende Arbeiten 106 6.2.1 Messtechnik 106 6.2.2 Anwendung 107 Literaturverzeichnis 109 Publikationsverzeichnis 117 Artikel in Zeitschriften mit peer-review 117 Tagungsbeiträge 117 Patente 119 / For the efficient use of renewable energies, energy storage systems are required that are environmentally friendly, low priced and scalable. The zinc-air flow battery (ZAB), which is operated by pumping an opaque suspension of zinc particles in an gelled electrolyte through an electrochemical cell, is a promising candidate as energy storage system for these requirements. To design the fluidic structures and avoid malfunction, a fundamental understanding of the rheology of the zinc suspension is required. Additionally, the electrical performance of the cell can be imporved by optimizing the flow in the electrochemical cell. The liquid phase of the suspension itself has complex non-Newtonian properties, which are even more complex when the particles are considered. For the fundamental understanding of the suspension rheology, model experiments are conducted. In this work an L-shaped channel with a widening is used to represent relevant effects from the complex rheology of the suspension. To measure the flow field, a spatial resolution of 1 … 2 mm and a measurement area of 20 × 15 mm2 are required. Ultrasound can be used to measure the flow in opaque liquids, but wavefront distortions are introduced by the zinc particles. Established measurement methods for homogeneous opaque fluids, the Ultrasound Imaging Velocimetry (UIV) and the Ultrasound Doppler Velocimetry (UDV), were compared for the application at the suspension. The UIV has a 50 % lower random deviation, which makes it more suitable for the flow measurement in the suspension and it was adapted to the measurement conditions in the suspension. At a spatial resolution of 1.66 mm, a velocity uncertainty of 2.5 % axial and 4.1 % lateral to the ultrasound propagation were achieved. The application of the UIV to the suspension flow in the model experiment revealed a thixotropic behavior of the fluid, which resulted in a dead flow zone opposite to the inlet of the channel. The in situ measurement of the flow in an active ZAB, allows to correlate electrical performance and flow and thereby an improvement of the cell performance by adapting the flow. For the measurement in the anodic channel with a width of 2.6 mm, a spatial resolution of 100 µm is required because of the high velocity gradients due to the non-Newtonian rheology of the suspension. The high spatial resolution has to be achieved at low ultrasound frequencies, since the ultrasound does not penetrate into the suspension for high frequencies. To achieve this, the Super Resolution Ultrasound Particle Tracking Velocimetry (SRPTV) was used, which allows a spatial resolution beyond the diffraction limit. Harmonic Imaging is used to image isolated non-linear tracer particles, which are tracked for velocity estimation. The speckle and image distortion due to the induced wavefront distortions are compensated with a coherence weighting beamformer. A spatial resolution of 67 µm axial and 30 µm lateral to the ultrasound propagation were achieved. Despite the strong scattering of the ultrasound at the zinc particles, a maximum velocity uncertainty of 12.5 % referred to the maximum velocity was achieved for the measurement in the active ZAB. A slip velocity of 3 mm at a maximum velocity of 8 mm was observed. The SRPTV can be applied to other technical processes, where suspension flows in small geometries play an important role.:Symbolverzeichnis xiii Abkürzungsverzeichnis xv 1 Einleitung 1 1.1 Motivation und Zielstellung 1 1.2 Stand der Technik 4 1.3 Lösungsansatz und Struktur der Arbeit 8 2 Theoretische Grundlagen 11 2.1 Grundlagen der Schallausbreitung 11 2.1.1 Schallausbreitung in homogenen Medien 11 2.1.2 Schallausbreitung in inhomogenen Medien 13 2.2 Ultraschall Bildgebung 14 2.2.1 Phased-Array-Prinzip 15 2.2.2 Plane wave imaging 16 2.2.3 Grenzen der Schallfeldfokussierung 16 2.3 Messung von Strömungsfeldern 17 2.3.1 Ultraschall-Doppler-Velozimetrie 18 2.3.2 Ultrasound Imaging Velocimetry 19 2.3.3 Ultrasound Particle Tracking Velocimetry 19 2.4 Nichtlineare akustische Effekte 20 2.4.1 Beschreibung von Linearität 20 2.4.2 Interaktion von nichtlinearen Streupartikeln und Schallwelle 20 2.4.3 Harmonic Imaging 21 3 Experimentelle Grundlagen 25 3.1 Charakterisierung der Zinksuspension 25 3.1.1 Zusammensetzung der Zinksuspension 25 3.1.2 Bestimmung von Dämpfung und Schallgeschwindigkeit 26 3.1.3 Bestimmung der spezifischen akustischen Impedanz 29 3.2 Messtechnik 30 3.2.1 Ultraschallforschungsplattform: Phased Array Ultrasound Dopp- ler Velocimeter 30 3.2.2 Ultraschallwandler 32 4 Verfahren zur Strömungsmessung im Modellexperiment 37 4.1 Experimenteller Aufbau 37 4.2 Untersuchung geeigneter Verfahren zur Messung von Strömungsfel- dern in der Zinksuspension 38 4.3 Optimierung der Signalverarbeitung und Charakterisierung der Messei- genschaften 44 4.3.1 Geschwindigkeitsnormal 44 4.3.2 Optimierung der Messsystemparameter 45 4.3.3 Charakterisierung der Messeigenschaften 48 4.3.4 Validierung 49 4.4 Messung der Suspensionsströmung im Modellexperiment 55 4.4.1 Messergebnisse 55 4.4.2 Vergleich von Simulation und Messung 58 4.5 Fazit 61 5 Verfahren zur In-situ-Strömungsmessung in einer Zink-Luft-Flussbatterie 63 5.1 Experimenteller Aufbau 63 5.2 Strömungsmessung unterhalb des Beugungslimits - Super Resolution Ultrasound Particle Tracking Velocimetry (SRPTV) 65 5.2.1 Nutzung nichtlinearer Streupartikel 68 5.2.2 Trennung von linearem und nichtlinearem Signalanteil 72 5.2.3 Strahlformung mit Kompensation der Streuung 76 5.2.4 Particle Tracking 80 5.3 Charakterisierung der Messeigenschaften 81 5.3.1 Vorgehen zur Charakterisierung der Messeigenschaften 82 5.3.2 Untersuchung der Positionsunsicherheit 83 5.3.3 Untersuchung der Geschwindigkeitsunsicherheit 92 5.4 Messung an einer aktiven Zink-Luft-Flussbatterie 95 5.4.1 Aufbau und Durchführung 95 5.4.2 Messergebnisse 97 5.4.3 Vergleich von Simulation und Messung 97 5.5 Fazit 102 6 Zusammenfassung und Ausblick 103 6.1 Erkenntnisse und Fortschritt 103 6.1.1 Ultrasound Imaging Velocimetry 103 6.1.2 Super Resolution Ultrasound Particle Tracking Velocimetry 104 6.1.3 Fazit 106 6.2 Ausblick und weiterführende Arbeiten 106 6.2.1 Messtechnik 106 6.2.2 Anwendung 107 Literaturverzeichnis 109 Publikationsverzeichnis 117 Artikel in Zeitschriften mit peer-review 117 Tagungsbeiträge 117 Patente 119
20

Méthodes de microscopie par holographie numérique interférentielle en couleurs avec un éclairage partiellement cohérent

Dohet-Eraly, Jérôme 19 April 2017 (has links)
La présente thèse traite de méthodes en microscopie holographique numérique (MHN) en couleurs, avec un éclairage de cohérence spatiale partielle. Le principal inconvénient de la microscopie optique classique est sa faible profondeur de champ, rendant difficile l’observation de phénomènes dynamiques dans des échantillons épais. Au contraire, la MHN offre une reconstruction en profondeur grâce à la propagation numérique de l’hologramme. La MHN interférométrique donne aussi le contraste quantitatif de la phase, utile pour analyser des objets transparents. Un éclairage à plusieurs longueurs d’onde dans une configuration appropriée permet la MHN en couleurs. L’imagerie en flux et en couleurs de particules en MHN est ici développée, avec une méthode pour la correction automatique de la balance des couleurs et des défauts permanents. Elle est appliquée pour l’analyse du plancton dans des échantillons d’eau de surface et fournit des images de haute qualité pour les intensité et phase optiques. En outre, la réduction du bruit obtenue en diminuant la cohérence spatiale de l’éclairage en MHN est également étudiée, avec deux modèles évaluant quantitativement ce phénomène en fonction de la cohérence spatiale de la lumière et de la distance entre la source de bruit et le plan d’enregistrement. De plus, la MHN différentielle est aussi abordée. Celle-ci fournit les phases différentielles, la phase étant calculée par intégration. Cependant, les défauts présents conduisent à des aberrations lors du calcul de la phase, qui affectent sa qualité et empêchent la reconstruction holographique. Un traitement spécifique est développé, permettant la reconstruction numérique en profondeur. Enfin, en MHN, un critère est essentiel pour déterminer automatiquement la distance de netteté de l’objet. Deux critères de netteté sont ici mis au point, fonctionnant indépendamment de la nature de l’objet observé (amplitude, phase ou mixte). L’un, monochromatique, est basé sur l’analyse de l’amplitude et sur un filtrage passe-haut ;l’autre, qui détecte rapidement le plan de netteté en MHN en couleurs, compare la phase dans le domaine de Fourier entre les couleurs. Les méthodes développées dans la thèse montrent le potentiel élevé de la MHN en couleurs avec un éclairage partiellement cohérent spatialement, suggérant un avenir prometteur pour cette technique. / The thesis deals with methods and developments in color digital holographic microscopy (DHM), with a partial spatial coherence illumination. The principal drawback of classical optical microscopy is its poor depth of field, which makes difficult the observation of dynamic phenomena in thick samples. On the contrary, DHM provides reconstruction in depth thanks to numeric propagation of the recorded hologram. Another feature of interferometric DHM is the quantitative phase contrast imaging, useful for analyzing transparent objects. Usual DHM is limited to monochromatic case, but multispectral illumination in an appropriate setup leads to color DHM. Color in-flow imaging of particles in DHM is developed in the thesis, with a method for the automatic correction of color balance and permanent defects. It is applied to analyze plankton microorganisms in untreated pond water samples, and provides high quality images, for both optical phase and intensity. Moreover, noise reduction obtained when decreasing the spatial coherence of the illumination in DHM is also investigated in the thesis, with the development of two models that quantitatively assess the noise reduction as a function of both the spatial coherence of the illumination, and the defocus distance of the noise source. Furthermore, differential DHM (DDHM) is also studied in the thesis. As DHM gives the optical phase, DDHM provides differential phases, from which phase is retrieved by integration. However, misalignments and defects give some aberrations, which affect phase quality and hinder refocusing. A specific hologram processing is developed, giving an accurate phase image and enabling holographic reconstruction in depth. Finally, in DHM, a criterion is essential to automatically achieve the refocusing distance of the object. Two refocusing criteria are developed in the thesis, both working independently of the nature of the observed object (amplitude, phase, or both mixed). The first one, monochromatic, is based on amplitude analysis and on a high-pass filtering process. The second one, which gives fast refocusing in multispectral DHM, compares the phase in the Fourier domain among wavelengths. Methods developed in the thesis show the high potential of color DHM with a partial spatial coherence illumination, suggesting a promising future for this technique. / Doctorat en Sciences de l'ingénieur et technologie / info:eu-repo/semantics/nonPublished

Page generated in 0.0795 seconds