• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 60
  • 39
  • 19
  • 13
  • 6
  • 5
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 189
  • 189
  • 36
  • 33
  • 20
  • 16
  • 16
  • 15
  • 14
  • 14
  • 13
  • 13
  • 13
  • 13
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
91

Estudo da uniformidade de emissão de água utilizando diferentes espaçamentos entre gotejadores na linha lateral

Andrade, Luiz Antonio de [UNESP] 08 June 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:32:43Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-06-08Bitstream added on 2014-06-13T20:43:44Z : No. of bitstreams: 1 andrade_la_dr_botfca.pdf: 831598 bytes, checksum: b06b99430e825b80d7ec37981bcbe1c5 (MD5) / Universidade Estadual Paulista (UNESP) / A irrigação por gotejamento no Brasil está crescendo no cultivo de hortaliças e frutas de ciclo anual. O adequado dimensionamento do projeto de irrigação por gotejamento visando altos Coeficientes de Uniformidade de Emissão de água é coerente com a pressão da sociedade pelo uso racional dos recursos naturais, especialmente a água. A utilização de linhas laterais mais longas promove redução de custos na instalação do projeto, entretanto pode reduzir a uniformidade de emissão de água, sendo que a otimização deste fator é importante objetivo de todo projeto criteriosamente executado. Propôs-se um modelo de mangueira gotejadora com dois segmentos, sendo o ultimo com um espaçamento padrão, e o segmento inicial com um espaçamento especial entre os emissores, com o objetivo de obter linhas mais longas sem prejudicar o Coeficiente de Uniformidade de Emissão de água. Mangueira gotejadora dimensionada teoricamente conforme o modelo proposto, com lateral de 150,6 m sendo 59,7 m iniciais com espaçamento entre emissores de 0,35 m associada com 90,9 m finais com distancia entre gotejadores de 0,30 m apresentou variação de vazão de 8,05 % e CUECVf de 97,62% e foi 36% mais longa que a mangueira gotejadora com único espaçamento de 0,30 m, com variação de vazão de 10 %, e CUECVf de 94,71.Ganhos semelhantes foram obtidos com os espaçamentos padrões de 0,40 e 0,50 m. Concluiu-se que modelo proposto tem possibilidade de ser aplicado na pratica da irrigação por gotejamento em cultivo adensado, por apresentar melhor CUE, lateral mais longa e menor variação de vazão. / The use of drip irrigation in horticultural and annual cycle fruits in Brazil is growing. The correct sizing of a drip irrigation project, using High Emission Uniformity Coefficients, is in accordance with society's pressure for a rational use of natural resources. Sizing longer lateral irrigation lines promotes a cost reduction in the installation costs of a project. A model for a drip irrigation lateral composed of two segments is proposed; the last having a standard spacing, the initial segment having a special spacing between emitters, higher than the standard, with the objective of obtaining longer laterals, without decreasing the Emission Uniformity Coefficient of water, EUC.A theoretically dimensioned drip hose, in accordance with the proposed model, with a total length of 150.6 m, having the initial 59.7 m an emitter spacing of 0.3508 m, while the final 90.9 m an emitter spacing of 0.30 m, presented a flow variation of 8.05% and an EUC of 97.62%. It is 36% longer than a drip irrigation hose with a 0.30 m emitter spacing, with a 10% flow variation and a EUC of 94.71%. A substitution of the standard lateral model for the proposed lateral model still needs a field trial validation in order to justify its use, considering that the commercial production of this model is viable.
92

Estudo do rendimento térmico de um aquecedor solar parabólico redondo para viabilidade de uso comercial e residencial / Study the thermal efficiency of a solar heater round parabolic for viability of comercial and residential use

Jacob Filho, Pedro [UNESP] 05 July 2016 (has links)
Submitted by PEDRO JACOB FILHO null (pjacobf@uol.com.br) on 2016-07-20T20:06:06Z No. of bitstreams: 1 Dissertacao final corrigida pós defesa 200716.pdf: 1678965 bytes, checksum: 44aa3be37ada9a276264665cb406a1bb (MD5) / Approved for entry into archive by Ana Paula Grisoto (grisotoana@reitoria.unesp.br) on 2016-07-22T18:44:22Z (GMT) No. of bitstreams: 1 jacobfilho_p_me_guara.pdf: 1678965 bytes, checksum: 44aa3be37ada9a276264665cb406a1bb (MD5) / Made available in DSpace on 2016-07-22T18:44:22Z (GMT). No. of bitstreams: 1 jacobfilho_p_me_guara.pdf: 1678965 bytes, checksum: 44aa3be37ada9a276264665cb406a1bb (MD5) Previous issue date: 2016-07-05 / Esta dissertação teve como objetivo a utilização de uma antena parabólica de diâmetro de 2,20 m como aquecedor solar de água de fluxo contínuo. Para a realização dos experimentos foi necessária a adequação da antena de tal modo que os raios solares refletidos passassem pelo foco da mesma, contendo uma panela de pressão pintada de preto fosco em cujo interior tem uma serpentina de cobre para absorver a radiação solar. A parte experimental contou com as medidas do valor da radiação solar, temperatura de entrada e saída da água, temperatura ambiente ao sol, temperatura no foco e a velocidade do vento. Através das medidas realizadas calculou-se a taxa da quantidade de calor e do rendimento térmico obtidos com vazões de 3,6 L/h até 36 L/h com incrementos de 3,6 L/h. Para a vazão de 25,2 L/h obteve-se o melhor rendimento térmico com 44,45%, num dia típico de intensidade solar de 800 W/m² ± 10%, sem nuvens e com velocidade do vento abaixo de 2m/s. Entretanto para um dia totalmente nublado típico a radiação solar foi de 120 W/m² ± 10% e o valor da temperatura de saída da água do aquecedor foi igual ao valor da temperatura de entrada. Verificou-se, assim, a possibilidade da antena parabólica ser empregada como aquecedor solar de água com fluxo contínuo para fins comerciais e residenciais e, também, como um sistema de pré-aquecimento de fluídos. / This dissertation had as objective the use of a satellite dish diameter of 2.20 m as solar heater continuous flow of water. For the realization of experiments was necessary the adequacy of the antenna so that the solar rays reflected receipted by focus of same, containing a pressure cooker painted black opacities in whose interior has a serpentine of copper to absorb solar radiation. The experimental part featured the measures of the value of the solar radiation, input and output temperature of water, sun ambient temperature, the temperature in the focus and wind speed. Through measurements performed it was calculated the amount of heat obtained with adequate flow of 3.6 L/h up to 36 L/h with increments of 3.6 L/h. For the flow of 25,2 L/h it was obtained the best thermal efficiency with 44.45% on a typical day of solar intensity of 800 W/m ² ± 10% without clouds and wind speed below 2 m/s. However for a day totally cloudy typical solar radiation was 120 W/m ² ± 10% and the temperature of the water heater's output was equal to the value of input temperature. It was found, so the possibility of satellite dish be used as solar water heater with continuous flow for commercial and residential purposes and also as a pre-heating system fluids.
93

Estudo da influência do solvente orgânico e do fluxo de injeção no controle de tamanho de nanocápsulas de núcleo lipídico preparadas através do método de deslocamento de solvente

Klein, Alana Carina January 2013 (has links)
O fluxo de injeção e o solvente orgânico, utilizado no preparo de nanoesferas poliméricas, são parâmetros experimentais que controlam o diâmetro e a distribuição de diâmetro das nanopartículas, formadas pelo processo conhecido como nucleação. Considerando as nanocápsulas de núcleo lipídico, formadas pelo processo de auto-organização, estes parâmetros experimentais ainda não foram explorados. Assim, esse trabalho propõe avaliar o fluxo de injeção e o solvente orgânico na preparação destas suspensões aquosas, caracterizando físicoquimicamente estes sistemas. Para variação de fluxo de injeção, utilizou-se uma bomba peristáltica, sendo possível a avaliação dos seguintes fluxos: 5, 8, 12, 15, 21 e 38 mL min¯¹. O diâmetro das nanocápsulas diminuiu de 256±9 nm a 127 ±8 nm pela técnica de difração de laser e 220±9 nm a 124±13 nm, segundo a técnica de espectroscopia de correlação de fótons. Os solventes orgânicos avaliados foram a acetona, acetonitrila e 1,4-Dioxano. Observou-se que a acetonitrila se mostrou adequada para a condição previamente otimizada com acetona, ao passo que o 1,4-Dioxano apresentou um pico micrométrico em sua distribuição. Assim, foi possível modelar este estudo através de um fatorial de design 2², onde têm-se dois fatores, fluxo de injeção e solvente orgânico, em dois níveis, nos fluxos de 5 e 38 mL min¯¹ e considerando os solventes acetona e acetonitrila. Como resultado, viu-se que o fluxo de injeção é o parâmetro de maior influência na preparação destas suspensões aquosas, se comparado ao solvente orgânico selecionado. Para elucidar o papel do solvente orgânico na preparação destes sistemas, calculouse os parâmetros de solubilidade e os coeficientes de difusão solvente orgânico\água e água\solvente orgânico para os três pares avaliados neste trabalho. Viu-se que os parâmetros de solubilidade e os coeficientes de difusão solvente orgânico\água explicam a não variação do diâmetro de partícula em função do solvente orgânico. Ainda, realizou-se um estudo de viscosidade, em função do log [PCL], para fases orgânicas preparadas com acetonitrila e 1,4- dioxano. Obteve-se o valor de 2,30 mg mL¯¹ para a concentração de agregação crítica quando utilizado o 1,4-Dioxano e 10,47 mg mL¯¹ para a fase orgânica preparada com acetonitrila. Então, pode-se dizer que este valor elevado encontrado para a acetonitrila é uma vantagem de sua utilização, uma vez que as características nanoscópicas são mantidas e um maior número de partículas pode ser formado. / Flow rate and organic solvent, used to prepare polimeric nanospheres, are experimental parameters that control the size and the size distribution curves of these nanoparticles, formed by particle nucleation. Considering the lipid core nanocapsules, formed by self-assembled process, these experimental parameters are not evaluated yet. Considering those, this work proposes to evaluate the flow rate and the organic solvent in the preparation of these aqueous suspensions, characterizing them physicochemically. To change the flow rate, it was used a peristaltic pump, it being possible to evaluate the following flows: 5, 12, 15, 21 and 38 mL min‾¹. The nanocapsules diameters decreased from 256±9 nm to 127 ±8 nm, by laser difratometry and 220±9 nm to 124±13 nm, by the photon correlation spectroscopy technique. The organic solvents evaluated were acetone, acetonitrle and 1,4-dioxane. It was observed that the acetonitrile was adequate for the condition previously optimized with acetone, whereas in the 1,4-dioxane distribution apears a micrometric peak. So, it was possible to modelate this study by a 2² factorial design, two factors, flow rate and organic solvent, in two levels, 5 and 38 mL min‾¹, considering acetone and acetonitrile. As a result, it was seen that the flow rate is the most influential parameter in the preparation of aqueous suspensions, compared to organic solvent selected. To elucidate the role of organic solvent in these systems, it was calculated the solubility parameter and the diffusion coefficients organic solvent/water and water/organic solvent to the three pairs evaluated in this work. It was seen that the solubility parameter and diffusion coefficient organic solvent/water explain the same diameter of the nanocapsules, even the change on the organic solvent. Even so, it was done a viscosity study, as a function of log [PCL], to organic phases prepared with acetonitrile and 1,4-dioxane. It was obtained a value of 2,30 mg mL‾¹ to the critical aggregation concentration to the 1,4-dioxane solvent, and the value of 10,47 mg mL‾¹ to the acetonitrile solvent. So, it can be said that this high value found for acetonitrile is an advantage in its use, since the nanoscopic characteristics are maintained and a larger number of nanoparticles can be formed.
94

Xerostomia em pacientes idosos: relação com o fluxo salivar, proteínas totais, capacidade tampão, pH e medicação em uso / Xerostomia in the elderly: relation to salivary flow rate, proteins, buffer capacity, pH and drugs

Adriana Oliveira Terci 30 November 2007 (has links)
O objetivo deste trabalho foi o de investigar as relações entre a queixa de boca seca, em uma população de idosos em bom estado geral, com o fluxo salivar não estimulado, a concentração de proteínas salivares, o pH e a capacidade tampão da saliva, além de considerar as medicações de uso diário consumidas por esses indivíduos. Foram selecionados de forma seqüencial e aleatória 85 pacientes, 13 homens e 72 mulheres, entre os 60 e 82 anos de idade, com média de 68,5 anos. Vinte e um pacientes, todos do sexo feminino, apresentaram queixa de boca seca, quando questionados. Sessenta e sete pacientes utilizavam algum tipo de medicação (79% da casuística). Dezoito indivíduos não consumiam medicamentos, 15 entre os não queixosos de boca seca e apenas três entre os que apresentaram queixa de boca seca. Foram colhidas amostras de saliva de todos os indivíduos, segundo técnica de expectoração não estimulada para recipiente mantido sob refrigeração, durante 15 minutos. Foram feitas, imediatamente após a coleta, o cálculo do fluxo salivar em mililitros por minuto, as medidas do pH, da capacidade tampão e reservados 2ml de saliva em recipiente refrigerado para os procedimentos da pesquisa da concentração proteica salivar. Ainda após a coleta foi aferida a glicemia pós-prandial dos pacientes. Obtivemos os seguintes resultados: Fluxo salivar médio geral de 0,21ml/min; mulheres com queixa 0,16 ml/min; e pacientes sem queixa 0,22ml/min. Capacidade tampão geral de 0,42; mulheres com queixa 0,46; pacientes sem queixa 0,40. Com relação ao pH média geral de 7,22; mulheres com queixa 7,0; pacientes sem queixa 7,22. Concentração de proteínas totais média geral 2,98mg/ml; mulheres com queixa 3,30 mg/ml; pacientes com queixa 2,88 mg/ml. Concluímos que a queixa de xerostomia é mais comum em mulheres e pacientes de maior idade, apresentando correlação positiva com fluxo salivar baixo, maior concentração proteica e maior consumo de medicamentos de uso crônico / The purpose of our trial was to investigate the influence of salivary flow rate, pH, protein content and buffer capacity over the symptom of xerostomia in a population of elderly people exhibiting good health. Eighty-five individuals were randomly selected, 13 men and 72 women, 60 to 82 years, mean 68.5. Twenty-one female patients presented dry mouth complaint when questioned. Seventy-seven patients (79%) were using some type of medication. Eighteen patients were not using drugs, 15 with no dry mouth complaint and three with xerostomia. Unstimulated whole saliva was collected for a period of 15 minutes to a refrigerated recipient. Salivary flow rate, pH and buffer capacity were measured immediately after sampling. Protein concentration was measured later at the lab center in a 2ml sample reserved for this procedure. Additionally, all patients had their glucose level taken. The following results were obtained: mean salivary flow rate of 0,21 ml/min, 0,16 for xerostomia patients and 0,22 for non-xerostomia patients. Mean salivary buffer capacity of 0,42; 0,46 for xerostomia patients and o,40 for non xerostomia patients. Mean pH of 7,22; 7,0 for xerostomia patients and 7,22 for non xerostomia patients. Mean protein concentration of 2,98 mg/ml; 3,30 for xerostomia patients and 2,88 for non xerostomia patients. We concluded that xerostomia is more prevalent in women and older patients, presenting positive correlation with low salivary flow rate, greater protein concentration and multiple drug use.
95

Avaliação da relação entre estresse e a concentração de compostos sulfurados volateis no halito bucal

Queiroz, Celso Silva 13 December 1999 (has links)
Orientador: Jaime Aparecido Cury / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-25T22:05:28Z (GMT). No. of bitstreams: 1 Queiroz_CelsoSilva_M.pdf: 4148499 bytes, checksum: a250fc32bc9b3c95e74bc4505b1ca920 (MD5) Previous issue date: 1999 / Resumo: O objetivo do trabalho foi avaliar a relação entre o estresse e a concentração dos compostos sulfurados voláteis (CSV) no hálito bucal. Para tanto, foram avaliadas duas condições estressantes: Estudo I - prova; Estudo II - tensão pré-menstrual (TPM). O Estudo I foi composto de 2 grupos: A e B. O grupo A (34 voluntários), foi subdividido em 18 voluntários com estresse e 16 voluntários sem estresse. As concentrações dos CSV e foram medidas 1 semana antes da prova, no dia e 1 semana após, através do monitor de sulfetos (Halimeter) e o fluxo salivar também foi mensurado. No grupo B (37 voluntários), além dessas análises foram mensurados o pH, "capacidade tampão", cálcio, fósforo e proteína na saliva. O Estudo II foi composto por 50 voluntárias: 27 mulheres sem TPM (controle) e 23 mulheres com TPM. As mensurações dos CSV e do fluxo salivar foram realizadas nos períodos não-menstrual, pré-menstrual e de menstruação. A análise estatística mostrou que tanto no Grupo A (n=34) quanto no Grupo B (n=37) a concentração dos CSV no dia da prova foi maior (p<0,05) enquanto que a taxa de fluxo salivar foi menor (p<0,05). Os voluntários com estresse (n=18) e sem estresse (n=16) também apresentaram maiores concentrações de CSV no dia da prova (p<0,05), enquanto o fluxo salivar foi menor somente nos voluntários não estressados (p<0,05). A análise bioquímica da saliva do Grupo B revelou - que o pH foi menor no dia da prova (p<0,05), e as demais análises não foram diferentes (p>0,05). No Estudo II, as voluntárias sem TPM (n=26) apresentaram maior concentração dos CSV no período menstrual (p<0,05). Enquanto nas voluntárias com TPM (n=23) a concentração dos CSV foi maior (p<0,05) nos períodos menstrual e pré-menstrual. Já o fluxo salivar não mostrou diferenças (p>0,05). Os resultados sugerem que o estresse é um fator pré-disponente da halitose, cujo mecanismo não pode ser explicado somente pela diminuição do fluxo salivar / Abstract:The aim of study was to evaluate the relationship between stress and volatile sulfur compounds (VSC) present in mouth air. Thus, two stressfull conditions were evaluated: Study 1- examination; Study II - premenstrual syndrome (PMS). Study I was composed of 2 groups: A and B. Group A (34 volunteers), was divided in 18 volunteers with stress and 16 volunteers without stress. VSC concentrations were measured a week before, on day and a week after the exam using a sulfide monitor (Halimeter) and the salivary flow was measured. In group B (37 volunteers), others analyisis as pH, "buffer capacity", proteins, calcium and phosphorus, in saliva were performed. In study II, fifty women were selected: 27 women without PMS symptoms (control group) and 23 women with PMS symptoms. The measurements were performed during non-menstrual, PMS and menstrual periods. The statistical results showed in both groups A and B an increase of VSC concentration on the exam day (p<0.05) and the salivary flow was lower (p<0.05). Volunteers with stress (n=18) and without stress (n=16), presented higher VSC concentration on the exam (p<0.05), but there was statistical diferences in the salivary flow rate only in the volunteers without stress (p<0.05). The biochemistry analisys of the saliva in group B showed that pH was lower on the exam day (p<0.05), and others analisys were not statistical differences (p>0.05). In study II, the volunteers without PMS symptoms (n=26) presented higher VSC concentration in the menstrual period (p<0.05). Volunteers with PMS (h=23) showed a greater VSC concentration in both menstrual and PMS periods (p<0.05). Salivary flow rate was not statistically different (p>0.05). The results suggest that stressful conditions can be a predisposing factor for bad breath, and the mechanism cannot be explained only by the decrease of the salivary flow / Mestrado / Fisiologia Oral / Mestre em Odontologia
96

Assessment of the varitarget nozzle for variable rate application of liquid crop protection products

Daggupati, Naga Prasad January 1900 (has links)
Master of Science / Department of Biological & Agricultural Engineering / Robert E. Wolf / Traditionally, growers spray uniform application of pesticides over the target area regardless of variations in pest infestations. In recent years, variable rate application (VRA) technologies have made it possible to apply pesticides in variable rates across the field. In pesticide application, nozzles play a vital role. In general, pesticides are applied using conventional nozzles. Most conventional nozzles vary flow rates only over a 2:1 range when operated within the recommended pressure range due to a fixed spray orifice. Conventional nozzles vary droplet sizes tremendously when there are speed and application rate changes which results in inefficient application. Conventional nozzles have limitations when used for VRA. A new nozzle called Varitarget nozzle (U.S. Patent No. 5,134,961) was developed and marketed by Bui, (2005) to overcome the limitations with conventional nozzles. Varitarget nozzles have a variable orifice that changes in size in response to pressure changes, allowing varying flow rates with a minimal change in droplet size. Laboratory tests and field tests were conducted to study the performance of Varitarget nozzle. Varitarget black/blue and clear/yellow caps were evaluated in this study. Lab studies were conducted to measure Varitarget characteristics compared to conventional nozzles. The flow rate ratios of Varitarget nozzle black and clear caps were 12:1 and 10:1 while the conventional nozzles produced flow rate ratios ranging from only 3:1 to 4:1. The measured flow rate of Varitarget nozzle black and clear caps was similar to that published by the manufacturer up to 40 psi and varied higher after 40 psi. Both Varitarget black and clear cap nozzle was within the standard VMD requirements until 40 psi and showed increasing trend while the conventional nozzles matched the standard VMD requirements. The VT black and clear cap nozzles showed better coverage at higher pressures when compared to conventional nozzles. CV values for VT black and clear capped nozzles were less than 10% which indicates capability of good uniform distribution. Spray angle of 110 degrees for VT black and clear capped nozzles was consistent over a range of pressures. Field studies were also conducted to compare the Varitarget to conventional nozzles. In the varying speed study, droplet size varied from 498 to 621 microns with a SD of 47.50 for VT black nozzle and 465 to 599 microns with a SD of 54.08 for VT clear cap nozzle as the speed varied from 4 to 12 mph. In the varying application rate study, The droplet size varied from 432 to 510 microns with a SD of 27.84 for VT black nozzle and 355 to 452 microns with a SD of 39.80 as the application rate varied from 4 to 12 GPA. In both studies, the observed pressure range required for spraying was minimum and varied slightly.
97

[en] INJECTIVITY TESTS IN MULTILAYERED RESERVOIRS: AN APPROXIMATE SOLUTION CONSIDERING MULTIPLE RATES / [pt] TESTES DE INJETIVIDADE EM RESERVATÓRIO MULTICAMADAS: SOLUÇÃO APROXIMADA PARA UM ESQUEMA DE MÚLTIPLAS VAZÕES

JESSICA LAILLA FERREIRA BITTENCOURT NETO 24 September 2020 (has links)
[pt] A injeção de água como método de recuperação de petróleo é usualmente utilizada devido à sua eficiência em recuperar óleo que encontra-se recluso no reservatório. Um teste de injetividade consiste basicamente em injetar uma fase (água ou gás) continuamente, por um determinado período de tempo, em um reservatório saturado de óleo. A partir da análise do comportamento da pressão no poço, esse procedimento tem por finalidade estimar, além do volume de óleo recuperável, parâmetros do reservatório, tais como permeabilidade, efeito de película, entre outros. Na atualidade, na literatura são encontrados estudos relativos a um único período de injeção (e um único período de fall-off) em reservatórios multicamadas e estudos relativos a reservatórios de camada única considerando vazão de injeção variável. Em vista disto, este trabalho tem como objetivo propor uma solução analítica aproximada para o comportamento da pressão em um reservatório multicamadas considerando um esquema de múltiplas vazões. A acurácia da solução proposta foi avaliada a partir da comparação com um simulador numérico de diferenças finitas em diferentes cenários. Os resultados exprimem uma considerável consonância entre os dados fornecidos pelo simulador numérico e o modelo proposto. / [en] The water injection is usually used as an oil recovery method due to its efficiency in recovering oil that is trapped in the reservoir. An injectivity test basically consists of continuously injecting a phase (water or gas), for a certain period of time, into an oil-saturated reservoir. From the analysis of the wellbore pressure behavior, this procedure aims to estimate, in addition to the volume of recoverable oil, parameters of the reservoir, such as permeability, film effect, among others. Nowadays, in the literature are found studies referring to a single injection period (and a single fall-off period) in multilayer reservoirs and studies referring to a single layer reservoirs considering variable injection flow-rates. In this context, this work aims to propose an approximate analytical solution for the pressure behavior in a multilayer reservoir considering a scheme of multiple flow-rates. The accuracy of the proposed solution was evaluated by comparison to a commercial finite difference-based flow simulator in different scenarios. The results express a considerable agreement between the data provided by the numerical simulator and the proposed model.
98

Modeling the Effect of Calcium Concentration and Volumetric Flow Rate Changes on the Growth of Rimstone Dam Formations Due to Calcium Carbonate Precipitation

Groshong, Kimberly Ann January 2008 (has links)
No description available.
99

A Statistical Analysis of Hydrocyclone Parameters

Hsiang, Thomas C. H. 12 1900 (has links)
Both Part I and Part II are included. / The separation of a mixture of glass spheres in water using 2 inch hydrocyclones was studied. <p> Three operating parameters were investigated: feed concentration, volume split and feed flow rate. In addition, three design parameters were cone angle, inlet diameter, and vortex finder length. The performance criterion parameters were the efficiency with which the solids were separated from the liquid, and the energy required per unit mass flowing through the hydrocyclone. </p> <p> First the experimental data were analyzed by three different statistical methods and the results compared in an attempt to determine which statistical method was most suitable for this two criteria system. The three methods were principal component analysis, canonical correlation analysis and multiple regression analysis. The theory behind these methods is briefly outlined. Our conclusion is that using all three methods give much more insight than could be obtained from any individual method. </p> <p> Second, an analysis of the above eight hydrocyclonc parameters of hydrocyclones with cylindrical sections indicated that for the range of parameters covered in this work, feed flow rate and inlet diameter influenced the energy loss most; volume split influenced the separation efficiency the most. Energy loss and separation efficiency are quite independent; this means that it is possible to design and run a hydrocyclone with high separation efficiency and low energy loss. The dilute concentrations used in this work indicate that a hydrocyclone of conventional design can be used in waste water treatment. When the parameters were correlated, a power model gave more consistent interpretation than a linear model. </p> <p> Third, the effect of the three operating parameters on hydrocyclones with three different body shapes suggested that the most efficient cyclone was one with a straight cone and no cylindrical section. The body shape dictated which parameters would significantly affect performance. </p> / Thesis / Master of Engineering (ME)
100

An Investigation of the Feasibility of Applying Frequency Response Analysis to Study Fluid Flow Reactors

Horneck, Harold S. 09 1900 (has links)
A frequency response tracer technique was used to study the hydraulic properties of a laboratory flow through reactor with variations in reactor size, flow rate and applied mixing. At any one set of conditions the reactor was studied over a range of input sine wave frequencies. Theoretical models consisting of in-series networks of completely mixed segments, plug flow segments, and dead space allowances were developed to approximate the experimental findings. / Thesis / Master of Engineering (ME)

Page generated in 0.0717 seconds