• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 18
  • 13
  • 6
  • Tagged with
  • 37
  • 19
  • 11
  • 11
  • 9
  • 7
  • 7
  • 7
  • 7
  • 6
  • 6
  • 5
  • 5
  • 5
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Contribution à l'exploitation du bruit ambiant pour le contrôle santé intégré passif des barres et des tubes / Contribution to the explotation of ambiant noise for the structural health monitoring of bars and pipes

Hourany, Karl 17 December 2015 (has links)
Les travaux présentés dans ce manuscrit sont basés sur des études précédentes réalisées à l’Institut d’Électronique de Microélectronique et de Nanotechnologie (IEMN) de l’Université de Valenciennes et du Hainaut Cambrésis (UVHC). Ils concernent le développement d’un système de surveillance embarqué destiné au contrôle des matériaux et des structures utilisés dans différents domaines de transport (fluidique, tubulaire, aéronautique, ferroviaire…). Il s’agit du principe de Contrôle Santé Intégré CSI (ou SHM en anglais pour Structural Health Monitoring). L’idée est d’intégrer des capteurs sur les surfaces des structures à contrôler pour aboutir à un système de contrôle non destructif de ces dernières durant la totalité de leurs fonctionnements. Tout d’abord, les travaux réalisés à l’IEMN dans ce domaine sont illustrés, quelques définitions comme celles des ondes ultrasonores, du Contrôle Non Destructif et du Contrôle Santé Intégré sont rappelées, avant d’aborder l’explication du passage d’un contrôle actif à un contrôle passif. Dans un deuxième temps, un algorithme de comparaison d’images basé sur les minimums locaux présents dans ces images a été proposé et testé sur des images simples de seize pixels, et a permis de tester le degré de ressemblance entre elles. L’explication de l’algorithme développé est divisée en deux grandes parties. Dans la première nous expliquons comment extraire les minimums locaux d’une image. La deuxième partie expose la procédure pour déterminer le taux de ressemblance entre les images. La simulation de la propagation d’un signal dans une plaque réverbérante et l’obtention des images temps-fréquence correspondantes à des corrélations filtrées (autocorrélation) ont été décrites. L’algorithme proposé a été validé sur ces images, permettant ainsi la localisation d’une position inconnue de la source. / The works presented in this manuscript are based on previous studies conducted at the Institute of Electronics Microelectronics and Nanotechnology of the University of Valenciennes and Hainaut Cambrésis. They concern the development of an embedded monitoring system for the control of materials and structures used in different transport domains (pipeline, aerospace, railway ...). This is the Structural Health-Monitoring principle. The idea is to integrate sensors into the surfaces of the controlled structures in order to achieve a non-destructive control system for the control of the latter during their entire lifetime. First the work done at the laboratory in this domain, are illustrated, some definitions such as ultrasonic waves, the Non Destructive Testing and the Structural Health Monitoring are recalled, to switch later to the explanation of the passage from an active control to a passive control. In a second step, an images comparison algorithm based on the local minima present in these images has been proposed and tested on simple images of sixteen pixels and was used to test the degree of resemblance between them. The explanation of the developed algorithm is divided into two parts. In the first one, we explain how to extract the local minima of an image. The second part describes the procedure for determining the rate of resemblance between the images. The simulation of the propagation of a signal in a reverberant plate and the obtaining of the frequency time images corresponding to filtered correlation (autocorrelation) has been described. The algorithm was validated on those images allowing the localization of an unknown source position.
32

Conception, fabrication de nouvelles puces microfluidiques à géométrie programmable et reconfigurable reposant sur les principes d'électromouillage sur diélectrique et de diélectrophorèse liquide

Renaudot, Raphael 06 November 2013 (has links) (PDF)
Dans le domaine des Lab-on-a-chip (LOC), la géométrie des canaux d'une puce microfluidique est souvent spécifique à la réalisation d'un protocole donné. La géométrie d'une puce est définie à l'étape de conception, avant les étapes de fabrication (généralement longues et coûteuses), et ne peut être modifiée a posteriori. Ce constat devient problématique lorsque la géométrie ne répond pas de façon satisfaisante au cahier des charges et qu'un nouveau lot de fabrication doit être démarré afin de redimensionner la puce. Pour pallier cet inconvénient, nous proposons de développer des puces microfluidiques génériques dont la géométrie est programmable et reconfigurable. Ce concept s'appuie largement sur les deux techniques de microfluidique digitale, l'électromouillage sur diélectrique (EWOD) et la diélectrophorèse liquide (LDEP). La première voie d'étude se concentre sur la technique de microfluidique LDEP. Tout d'abord, un modèle électromécanique, décrivant les comportements des liquides lors d'actionnements par LDEP ou EWOD, est établi. Ce modèle sert ensuite de base pour la conception et la fabrication de designs LDEP. Ces derniers sont testés afin d'identifier les géométries et les empilements technologiques, offrant des actionnements LDEP optimisés. L'étude, qui prend en compte un grand nombre de paramètres, montre que, avec des configurations et conditions spécifiques, les actionnements de liquide par LDEP offrent des performances égales, a minima, sur certains points, et supérieures sur d'autres par rapport à l'ensemble des études reportées dans la littérature. Enfin, un protocole de fonctionnalisation de surface par des spots de polymère de quelques microns à plusieurs dizaines de microns de diamètre, utilisant la technologie LDEP, est décrit. Cette méthode est susceptible de concurrencer directement les méthodes de fonctionnalisation classiques. La seconde voie d'étude traite du concept de géométrie programmable et reconfigurable, à l'aide de plateformes microfluidiques couplant les effets LDEP et EWOD. Dans un premier temps, les plateformes en configuration " ouverte " permettent de produire des moules à géométrie programmable pour la réalisation de puces microfluidiques en PDMS. Les résultats de cette étude prometteuse aboutissent, entre autres, à la réalisation de géométries de canaux complexes et typiques dans le domaine de la microfluidique (jonctions en " T " et valves de type " Quake "). Dans un second temps, les résultats les plus aboutis de ce manuscrit sont exposés à propos du concept de géométrie programmable et reconfigurable en utilisant de la paraffine. Un protocole spécifique, exploitant judicieusement les déplacements de liquides par EWOD et LDEP, donne lieu à la fabrication d'un grand nombre de puces microfluidiques, comportant des géométries de canaux complexes et variées. Dans les deux cas, un grand nombre de géométries peut être généré a à partir d'une seule plateforme microfluidique digitale générique. Les résultats obtenus ouvrent des perspectives de travail originales et prometteuses, dont certaines d'entre elles sont abordées en marge des objectifs initiaux. La première se trouve dans la continuité du concept de géométrie programmable et reconfigurable, en proposant une technologie à bas coût (substrat souple en Kapton et impression d'électrodes avec de l'encre conductrice). La seconde perspective instruit la compatibilité des technologies comportant des structures résonantes de type MEMS et des structures métalliques LDEP (en polysilicium) à l'échelle submicronique.
33

Étude de la mécanotransduction dans la scoliose idiopathique de l’adolescence (SIA)

Wong, Guoruey 12 1900 (has links)
À ce jour, la scoliose idiopathique de l’adolescent (SIA) est la déformation rachidienne la plus commune parmi les enfants. Il est bien connu dans le domaine de recherche sur la SIA que les forces mécaniques, en particulier les forces biomécaniques internes dans le système musculosquelettique, pourraient jouer un rôle majeur dans l’initiation et le développement de la maladie. Cependant, les connaissances sur la transformation des forces et des stimulations mécaniques en activité biochimique sont peu abondantes. Cet axe de recherche est très prometteur et peut nous fournir de nouvelles idées dans le dépistage et le traitement de la SIA. Dans le cadre de cette étude, nous visons à caractériser la mécanotransduction chez les patients atteints de la SIA en employant des techniques novatrices aux niveaux in vivo et in vitro. Antérieurement dans notre laboratoire, nous avons démontré que les niveaux d’Ostéopontine (OPN) plasmatique chez l’humain corrèlent avec la progression et la sévérité de la maladie, et que ces changements sont observables avant le début de la scoliose. En plus, selon la littérature, l’OPN est une molécule sensible à la force mécanique, dont l’expression augmente en réponse dans de nombreux types de cellules chez plusieurs espèces. Toutefois, il n’existe aucune preuve que ce résultat soit valide in vivo chez l’humain. L’hétérogénéité physique et biochimique de la SIA pose un gros défi aux chercheurs. Souvent, il est très difficile de trouver des résultats ayant une grande applicabilité. Les études portant sur les facteurs biomécaniques ne font pas exception à cette tendance. En dépit de tout cela, nous croyons qu’une approche basée sur l’observation des contraintes de cisaillement présentes dans le système musculosquelettique pourrait aider à surmonter ces difficultés. Les contraintes de cisaillement physiologique sont générées par des courants de fluide en mouvement à l’intérieur des os. Aussi, elles sont omniprésentes et universelles chez l’humain, peu importe l’âge, le sexe, la condition physique, etc., ce qui veut dire que l’étudier pourrait fort bien avancer nos connaissances en formant une base fondamentale avec laquelle on pourra mieux comprendre les différences quant à la mécanotransduction chez les patients atteints de la SIA par rapport aux sujets sains. Pour ce projet, donc, nous proposons l’hypothèse que les sujets atteints de la SIA se différencient par leurs réponses respectives à la force mécanique au niveau cellulaire (en termes de l’expression génique) ainsi qu’au niveau in vivo (en termes du marqueur OPN et son récepteur, sCD44). Afin de vérifier la partie de notre hypothèse de recherche concernant l’aspect in vivo, nous avons recruté une cohorte de patients âgés de 9-17 ans, y compris i) des cas pré-chirurgicaux (angle de Cobb > 45°), ii) des cas modérément atteints (angle de Cobb 10-44°), iii) des témoins, et iv) des enfants asymptomatiques à risque de développer la scoliose (selon nos dépistages biochimiques et fonctionnels) d’âge et sexe appariés. Une pression pulsatile et dynamique avec une amplitude variant de 0-4 psi à 0.006 Hz a été appliquée à un des bras de chacun de nos sujets pour une durée de 90 minutes. Au tout début et à chaque intervalle de 30 minutes après l’initiation de la pression, un échantillon de sang a été prélevé, pour pouvoir surveiller les niveaux d’OPN et de sCD44 circulants chez les sujets. Nous avons découvert que le changement des niveaux d’OPN plasmatique, mais pas des niveaux de sCD44, corrélaient avec la sévérité de la difformité rachidienne chez les sujets, ceux ayant une courbe plus prononcée démontrant une ampleur de réponse moins élevée. Pour vérifier la partie de notre hypothèse de recherche concernant la réponse mécanotransductive cellulaire, des ostéoblastes prélevées à 12 sujets ont été mis en culture pour utilisation avec notre appareil (le soi-disant « parallel plate flow chamber »), qui sert à fournir aux ostéoblastes le niveau de contraintes de cisaillement désiré, de manière contrôlée et prévisible. Les sujets étaient tous femelles, âgées de 11-17 ans ; les patients ayant déjà une scoliose possédaient une courbe diagnostiquée comme « double courbe majeure ». Une contrainte fluidique de cisaillement à 2 Pa, 0.5 Hz a été appliquée à chaque échantillon ostéoblastique pour une durée de 90 minutes. Les changements apportés à l’expression génique ont été mesurés et quantifiés par micropuce et qRT-PCR. En réponse à notre stimulation, nous avons trouvé qu’il n’y avait que quelques gènes étant soit différentiellement exprimés, soit inchangés statistiquement dans tous les groupes expérimentaux atteints, en exhibant simultanément la condition contraire chez les témoins. Ces résultats mettent en évidence la grande diversité de la réponse mécanotransductive chez les patients comparés aux contrôles, ainsi qu’entre les sous-groupes fonctionnels de la SIA. Globalement, cette œuvre pourrait contribuer au développement d’outils diagnostiques innovateurs pour identifier les enfants asymptomatiques à risque de développer une scoliose, et évaluer le risque de progression des patients en ayant une déjà. Aussi, dans les années à venir, les profils mécanotransductifs des patients pourraient s’avérer un facteur crucial à considérer cliniquement, particulièrement en concevant ou personnalisant des plans de traitements pour des personnes atteintes. / Adolescent idiopathic scoliosis (AIS) is the most commonly occurring musculoskeletal deformity among children today. It is generally well accepted in scoliosis research that mechanical forces, especially the internal biomechanical forces of the musculoskeletal system, could well have a major role in the induction and pathogenesis of the disease. However, the process by which mechanical loads or stimuli are converted into biochemical activity (mechanotransduction) has not been explored so deeply. This emerging facet of research in AIS holds much promise for new insights into the disease. Here, we aim to characterize mechanotransduction in scoliosis patients using some novel techniques at both the in vivo and in vitro levels. Previously in our lab, we demonstrated that the level of plasma osteopontin (OPN) and sCD44 in the human body is a strong indicator of disease progression and severity, and that these changes are observable before scoliosis onset. In the literature, OPN in vitro is known to be mechanosensitive, showing upregulation in response to mechanical stress in a variety of cell types across many species. However, to the best of the author’s knowledge, no literature exists as to whether this behaviour carries over in vivo in humans. A major difficulty in AIS research is the heterogeneity of the disease, both physically and biochemically. Because of this, many times it is difficult to find results with wide applicability to patients. Study of biomechanical factors in AIS is no exception. We believe, however, that study of fluid shear stress in the musculoskeletal system may be able to solve this problem for mechanotransduction-related issues in AIS. Native physiological fluid shear stresses in humans are experienced in the musculoskeletal system, caused by fluid movement over cells therein. These fluid shear stresses are omnipresent and universal in all humans, regardless of age, gender, fitness level, etc., which means that studying it could very well go a long way towards establishing a fundamental basis of understanding the differences as to mechanotransduction in scoliosis patients as opposed to normal cases. In this project, then, we advanced the hypothesis that AIS patients are distinguishable in the way they respond to mechanical force at both the cellular level (in terms of gene expression) as well as globally at the in vivo level (in terms of the scoliosis marker OPN and its receptor sCD44). To test the in vivo portion of our hypothesis, we recruited a cohort of patients between the ages of 9-17, each one of which fell into one of 4 subject groups: i) surgical cases (pre-surgery, Cobb angle > 45°), ii) moderately affected cases (Cobb angle 10-44°), iii) controls, or iv) asymptomatic children at risk of developing scoliosis matched for age and gender against healthy controls. A dynamic, pulsatile, compressive pressure of variable amplitude from 0-4 psi at 0.006 Hz was applied to the arm of each subject for a period of 90 minutes. Initially and at intervals of 30 minutes after the start of force application, blood samples were taken in order to monitor circulating plasma OPN and sCD44 levels in subjects. We found that the change of circulating OPN levels, but not sCD44 levels, measured in vivo in response to our mechanical stimulation was statistically significantly correlated to status of spinal deformity severity, with more severely affected subjects demonstrating lower magnitudes of ΔOPN. To test the cellular portion of our hypothesis, osteoblasts from severely affected AIS patients and unaffected controls were cultured for use with our parallel plate flow chamber (PPFC) apparatus setup, which permits application of fluid shear stress patterns to cells in a predictable, controllable manner. Subjects were all females who fell into the 11-17 years age range, with scoliotic patients presenting with double major curves. A dynamic, sinusoidal and oscillatory fluid shear stress pattern was applied to osteoblasts at 2 Pa, 0.5 Hz for 90 minutes. Overall gene expression changes across RNA samples as a result of our stimulation were measured using microarray and qRT-PCR approaches. In response, only a very small number of genes are either mutually differentially expressed or statistically unchanged across all functional scoliotic subgroups while having the opposite condition in the control group, indicating a great degree of difference in terms of mechanotransductive response as compared internally between AIS functional subgroups, as well as between control and AIS patients. Globally, this project’s work may contribute to the development of innovative diagnostic tools to identify asymptomatic children at risk of developing scoliosis, and to assess the risk of curve progression at an early stage in those already affected. Also, in years to come, the mechanotransductive profile of a patient could be another integral factor to weigh, clinically, when considering or designing treatment plans for affected persons.
34

Experimental and Numerical Study of Micro-Fluidic Oscillators for Flow Separation Control / Etude Expérimentale et Numérique de Micro-Oscillateurs Fluidiques pour le Contrôle d'Ecoulements Décollés

Wang, Shiqi 01 September 2017 (has links)
Les oscillateurs fluidiques qui peuvent générer des excitations périodiques sont des actionneurs très prometteurs pour des applications de contrôle actif des écoulements. Les oscillations sont en effet complètement auto-induites et produites en l'absence de parties mobiles ce qui rend ces actionneurs très intéressants en termes de fiabilité et de robustesse. Ce travail de thèse avait pour objectif principal d'identifier les mécanismes physiques qui contrôlent la dynamique de fonctionnement de ce type d'oscillateurs fluidiques et de proposer des lignes directrices pour la conception d'oscillateurs dont les performances soient adaptées aux applications de contrôle d'écoulements envisagées. L'analyse expérimentale de plusieurs prototypes couplée à des simulations numériques a permis de mettre en évidence que le mécanisme de basculement du jet dans ce type d'oscillateurs est contrôlé par les gradients de pression existants au niveau de deux parties critiques de ces actionneurs. A partir de cette analyse, une relation simple a été établie permettant d'estimer la fréquence des oscillations. Deux méthodes de synchronisation, permettant le contrôle du déphasage entre les actionneurs, ont été proposées et validées expérimentalement ainsi qu'à l'aide de simulations numériques. Une matrice de micro­ oscillateurs fluidiques a été conçue, fabriquée et finalement intégrée sur une rampe installée en soufflerie. L'analyse expérimentale de son efficacité pour le contrôle de l'écoulement séparé a mis en évidence un gain important par rapport aux résultats obtenus lors de travaux précédents sur des écoulements de paroi similaires à l'aide d'autres types d'actionneurs fluidiques. / Fluidic oscillators which can generate periodic excitations are very promising for active flow control applications, due to their reliability and robustness, as their internal flow oscillation is totally self-induced and self-sustained. The main objective of this work is to identify the underlying mechanisms controlling the dynamics of this kind of fluidic oscillator and to propose guiding lines for the design of oscillators. Experimental analysis of several oscillator prototypes and associated numerical simulations have permitted to explain that the jet switching in this kind of oscillator is controlled by pressure gradients in two critical parts of the device. From these analyses, a simple function has been proposed to estimate the oscillation frequency. Two synchronization methods, allowing the control of the phase lag between the actuators, have been proposed and validated experimentally and by numerical simulations. An array of micro-fluidic oscillators has then been designed and tested on a ramp separated flow, showing much higher efficiency compared to other kind of fluidic actuators tested on similar wall flows in previous studies.
35

Nanofluidic insight into energy harvesting and desalination / Une approche nanofluidique de la conversion d’´energie et du dessalement

Sempere, Catherine 14 October 2015 (has links)
La première partie de cette thèse constitue une introduction aux différentes méthodes de conversion d'énergie et de dessalement qui seront évoquées dans cet ouvrage. Dans une deuxième partie, nous montrons que la conductance ionique d'un réseau de nanopores est sous-additive avec le nombre de pores. La contribution individuelle de chaque pore à la conductance globale tend vers une valeur nulle, pour un réseau suffisamment grand. On note que seuls des rapports de longueurs interviennent, et que le choix d'une échelle nanométrique n'a pas d'influence dans l'effet observé. Ensuite, dans une troisième partie, nous mesurons la perméabilité d'un réseau de pores à une échelle macroscopique. Là aussi, l'influence du réseau ne dépend pas de l'échelle du système. La perméabilité évolue en sens inverse de la conductance : elle est augmentée par la présence de pores voisins, mais dans une faible proportion. La quatrième partie se sert des résultats des deux parties précédentes, dans le but de déterminer une loi d'échelle pour la puissance électrique produite par courant d'écoulement et diffusio-osmose, deux méthodes de conversion d'énergie osmotique. On montre que les effets d'entrée ont un effet délétère sur cette conversion ; ils nécessitent des études plus approfondies. La dernière partie est un travail numérique sur un nouveau procédé de dessalement par osmose via une phase gaz, piégée dans des nanotubes hydrophobes. Son intérêt principal est l'utilisation de nanotubes plus gros que les pores des matériaux actuellement utilisés, donc moins susceptibles de s'encrasser. Par dynamique moléculaire, nous étudions la perméabilité et la sélectivité du dispositif / The first part of this thesis is an introduction to the different energy conversion and desalination methods that will be invoked in this work. In a second part, we show that the ionic conductance of a nanopore array is sub-additive with the number of pores. Individal contributions of each pore to the global conductance tend to a null value, if the network is big enough. We note that this phenomenon only involves length ratios, and that working at a nanometric scale does not have any influence. Then, in a third part, we measure the permeability of a pore array at a macroscopic scale. There too, the effect of the array does not depend on the scale of the system. Permeability evolves inversely to conductance: permeability is enhanced by the presence of neighboring pores, but in a smaller proportion than the ionic conductance falls under the same cause. The fourth part uses the results of the two preceding ones, to determine a scaling law for the electric power produced by streaming current and diffusio-osmosis, two methods of osmotic energy conversion. We show that entrance effects have a negative impact on such conversion, more efforts are needed to understand them better and circumvent them. The fifth and last part of this thesis is a numerical work on a new desalination device. It relies on osmosis through a gas phase which is trapped within a hydrophobic nanotube. Its main interest is to use nanotubes bigger than the pores of currently used materials, thus less prone to fouling. We use molecular dynamics methods to study the permeability and selectivity of this device
36

Conception, fabrication de puces microfluidiques à géométrie programmable et reconfigurable reposant sur les principes d’électromouillage sur diélectrique et de diélectrophorèse liquide / Conception, fabrication of programmable and reconfigurable geometry microfluidic chips, based on liquid dielectrophoresis and electrowetting on dielectric actuations

Renaudot, Raphaël 06 November 2013 (has links)
Dans le domaine des Lab-on-a-chip (LOC), la géométrie des canaux d'une puce microfluidique est souvent spécifique à la réalisation d'un protocole donné. La géométrie d'une puce est définie à l'étape de conception, avant les étapes de fabrication (généralement longues et coûteuses), et ne peut être modifiée a posteriori. Ce constat devient problématique lorsque la géométrie ne répond pas de façon satisfaisante au cahier des charges et qu'un nouveau lot de fabrication doit être démarré afin de redimensionner la puce. Pour pallier cet inconvénient, nous proposons de développer des puces microfluidiques génériques dont la géométrie est programmable et reconfigurable. Ce concept s'appuie largement sur les deux techniques de microfluidique digitale, l'électromouillage sur diélectrique (EWOD) et la diélectrophorèse liquide (LDEP). La première voie d'étude se concentre sur la technique de microfluidique LDEP. Tout d'abord, un modèle électromécanique, décrivant les comportements des liquides lors d'actionnements par LDEP ou EWOD, est établi. Ce modèle sert ensuite de base pour la conception et la fabrication de designs LDEP. Ces derniers sont testés afin d'identifier les géométries et les empilements technologiques, offrant des actionnements LDEP optimisés. L'étude, qui prend en compte un grand nombre de paramètres, montre que, avec des configurations et conditions spécifiques, les actionnements de liquide par LDEP offrent des performances égales, a minima, sur certains points, et supérieures sur d'autres par rapport à l'ensemble des études reportées dans la littérature. Enfin, un protocole de fonctionnalisation de surface par des spots de polymère de quelques microns à plusieurs dizaines de microns de diamètre, utilisant la technologie LDEP, est décrit. Cette méthode est susceptible de concurrencer directement les méthodes de fonctionnalisation classiques. La seconde voie d'étude traite du concept de géométrie programmable et reconfigurable, à l'aide de plateformes microfluidiques couplant les effets LDEP et EWOD. Dans un premier temps, les plateformes en configuration " ouverte " permettent de produire des moules à géométrie programmable pour la réalisation de puces microfluidiques en PDMS. Les résultats de cette étude prometteuse aboutissent, entre autres, à la réalisation de géométries de canaux complexes et typiques dans le domaine de la microfluidique (jonctions en " T " et valves de type " Quake "). Dans un second temps, les résultats les plus aboutis de ce manuscrit sont exposés à propos du concept de géométrie programmable et reconfigurable en utilisant de la paraffine. Un protocole spécifique, exploitant judicieusement les déplacements de liquides par EWOD et LDEP, donne lieu à la fabrication d'un grand nombre de puces microfluidiques, comportant des géométries de canaux complexes et variées. Dans les deux cas, un grand nombre de géométries peut être généré a à partir d'une seule plateforme microfluidique digitale générique. Les résultats obtenus ouvrent des perspectives de travail originales et prometteuses, dont certaines d'entre elles sont abordées en marge des objectifs initiaux. La première se trouve dans la continuité du concept de géométrie programmable et reconfigurable, en proposant une technologie à bas coût (substrat souple en Kapton et impression d'électrodes avec de l'encre conductrice). La seconde perspective instruit la compatibilité des technologies comportant des structures résonantes de type MEMS et des structures métalliques LDEP (en polysilicium) à l'échelle submicronique. / In the field of lab-on-a-chip (LOC) systems, the channel geometry of a microfluidic chip is often specific to perform a given protocol. The chip geometry is hence defined at the design step, before the fabrication steps (generally time consuming and expensive) and cannot be thereafter modified. This fact becomes an issue when the geometry does not fit satisfactorily to the specifications and a new batch of fabrication has to be started, to size afresh the microfluidic chip. To overcome this inconvenient we propose to develop a new generation of microfluidic chips with a programmable and reconfigurable geometry. This concept is widely based on both digital microfluidic techniques, the electrowetting on dielectrics (EWOD) and the liquid dielectrophoresis (LDEP) actuations. The first investigation is focused on the microfluidic technique LDEP. First, an electromechanical model for liquids behaviours during a EWOD or LDEP actuation is established. This model is then used as a basis for the LDEP patterns design and fabrication. The LDEP patterns are tested to identify the geometries and dielectric layers stacks which give optimized LDEP actuations. By taking into account a broad parameters range, the study shows that, within a precise setup and specific conditions, the LDEP actuations can have equal performances at the minimum, or better performances than those reported in the overall scientific literature until now. Finally, a surface functionalization protocol by polymer spots (diameter size ranging from a few microns to several dozens of microns) utilizing the LDEP technology is described. This method is likely to compete directly with the standard functionalization tools. The second investigation is dealing with the programmable and reconfigurable geometry concept, thanks to microfluidic platforms which get together both EWOD and LDEP technologies on a same component. Firstly, the microfluidic platform in a single plate configuration allows providing master molds with a programmable geometry for the PDMS microfluidic chip fabrication. The results about this promising study lead to the processing of complex channels geometries, typically used in the microfluidic field. Secondly, the more exciting results are exposed about the programmable and reconfigurable microfluidic concept, by using advantageously the paraffin material. A specific protocol which takes advantages of LDEP and EWOD liquids displacements produces a lot of various and different microfluidic chips with complex channels shapes. For both applications, a single generic microfluidic platform can generate a wide number of different geometries, which can be modified partially or totally thereafter. The obtained results open up novel and promising work prospects, which one of them are approached on the fringe of the initial purposes. The first one belongs to the continuity of the programmable and reconfigurable by suggesting a low cost technology based on flexible Kapton substrate and inkjet printing of silver nanoparticules. The second one investigates the technologies compatibility between MEMS/NEMS resonating structures and LDEP metal structures (in polysilicon) at the submicronic scale.
37

Contribution aux développements des technologies de compression polymères chargés pour la réalisation d'inserts métalliques micro-structurés / Hybridation of micro replication processes by hot embossing and roll to roll with loaded polymer for the realization of metallic micro-structured die cavity

Zhang, Jie 18 December 2013 (has links)
Les travaux menés dans le cadre de cette thèse sont focalisés sur les procédés deréplication permettant la transformation des mélanges en composants par les technologiesen séquentiel ou bien en continu, selon les applications visées. Les développementsconcernent la mise en place et l’hybridation de différents procédés de micro-réplication(estampage à chaud de polymère thermoplastique et par laminage circulaire entre deuxrouleaux). Ces deux procédés sont développés et optimisés pour l’élaboration decomposants micro-structurés ou de microcomposants possédant des propriétésfonctionnelles mécaniques ou thermo-physiques requises à partir de différents mélangeschargés en poudres métalliques ou en nanotubes de carbone. Des exemples de réalisationde composants structurés, à base d’un système micro-fluidique possédant plusieurs canauxde 200 microns par 200 microns et des réservoirs de diamètre de 2 mm, sont prises commeexemple tout au long de ces travaux de cette thèse. Différents travaux de caractérisationsont été entrepris pour optimiser les procédés de micro-réplication par estampage à chaud etpar laminage circulaire entre deux rouleaux. / The Ph.D subject concerns the study of two micro-replication processes by hotembossing and roll to roll processes for thermoplastic polymers and loaded polymers withpowders or carbon nanotubes. The micro-replication processes, realized in sequential orcontinuous ways, use some different elaborated loaded feedstocks in order to obtainstructural components or micro-component with high aspect ratio and mechanical orthermo-physical properties.A chain combining hot embossing and roll embossing and powder metallurgy have beendeveloped in our lab and investigated. The different micro mould die cavities have beenrealized with different micro-manufacturing process, elastomeric mould has been obtainedby casting process. Finally, a metallic structured die cavity has been obtained by combininghot embossing and debinding and sintering stages. The second topic is the comparison ofmetallic die cavity mould obtained by roll embossing or rolls embossing. Two demonstratorshave been developed during the preparation of this Ph.D period: first a metallic micro-fluidicsystem with micro-structuration with diameter of 1 mm for the reservoir and 200 microns by200 microns for the channel have been realized and characterized by different methods.Secondly, some functional micro-component has been obtained with carbon nanotube andsome specific properties in terms of mechanic and thermo-physical properties have beencharacterized.

Page generated in 0.0388 seconds