• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 7
  • Tagged with
  • 7
  • 7
  • 7
  • 5
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudo retrospectivo de 489 casos de fratura de mandíbula no período de dez anos / A retrospective study of 489 cases of mandibular bone fractures in ten years period

Medeiros, Eduardo Henrique Pantosso de 29 May 2014 (has links)
Este estudo tem como objetivo a análise retrospectiva de quatrocentos e oitenta e nove prontuários de pacientes que apresentaram fraturas do osso mandibular, pertencentes ao Serviço de Cirurgia e Traumatologia Buco-Maxilo-Faciais da Faculdade de Odontologia de Ribeirão Preto (FORP/USP) provenientes de atendimentos realizados no período compreendido entre agosto de 2002 e julho de 2012. A análise foi direcionada a dados relativos a variáveis populacionais como idade, gênero, cor e profissão. Também foram analisados os exames de imagem solicitados, vícios, etiologia, sinais e sintomas, classificação da fratura, fraturas associadas de face ou não, abordagem, tratamento, tempo para intervenção cirúrgica e internação, além do período de acompanhamento e complicações. O critério para a inclusão dos prontuários na amostra foram de apresentarem fratura de mandíbula, com preenchimento completo de informações e de possuírem o Termo de Consentimento Livre e Esclarecido. Como critérios de exclusão, foram desconsiderados os prontuários com preenchimento incompleto das informações e que não possuiam o Termo de Consentimento Livre e Esclarecido assinado. Os dados coletados por um único examinador foram transportados para uma planilha eletrônica utilizando o programa Microsoft Excel sendo realizada neste momento uma análise descritiva dos resultados obtidos. Tabelas e gráficos foram utilizados para a apresentação e interpretação destes dados. Concluimos que houve prevalência do gênero. / The aim of this study was to retrospectively analyse four hundred and eighty-nine patients files presenting fractures of the mandibular bone, incident from attendances at the Department of Traumatology and Maxillofacial Surgery, from the School of Dentistry of Ribeirão Preto (FORP/USP) during the period between August 2002 and July 2012. The analysis was directed through population data variables such as age, gender, race and profession. Imaging tests requested, addictions, etiology of trauma, signs and symptoms, fractures classification, associated fractures, approach, treatment, time to surgical intervention and hospitalization, apart from follow-up period and complications were also analyzed. The criterion for inclusion of records in the sample were experiencing jaw fracture with complete filling of information and having the Term of Consent. Exclusion criteria were disregarded the charts with incomplete filling of information and lacked the Term of Consent signed. The data collected by a single observer were transported to a spreadsheet using Microsoft Excel program currently being conducted to a descriptive analysis of the results. Tables and graphs were used for the presentation and interpretation of these data. We conclude that there was a prevalence of male gender, white race, aged between 21-30 years with fractures of the left side, unilateral, etiology traffic accident. Most fractures were treated surgically, intraoral access were prevalent and complication rates were low.
2

Estudo retrospectivo de 489 casos de fratura de mandíbula no período de dez anos / A retrospective study of 489 cases of mandibular bone fractures in ten years period

Eduardo Henrique Pantosso de Medeiros 29 May 2014 (has links)
Este estudo tem como objetivo a análise retrospectiva de quatrocentos e oitenta e nove prontuários de pacientes que apresentaram fraturas do osso mandibular, pertencentes ao Serviço de Cirurgia e Traumatologia Buco-Maxilo-Faciais da Faculdade de Odontologia de Ribeirão Preto (FORP/USP) provenientes de atendimentos realizados no período compreendido entre agosto de 2002 e julho de 2012. A análise foi direcionada a dados relativos a variáveis populacionais como idade, gênero, cor e profissão. Também foram analisados os exames de imagem solicitados, vícios, etiologia, sinais e sintomas, classificação da fratura, fraturas associadas de face ou não, abordagem, tratamento, tempo para intervenção cirúrgica e internação, além do período de acompanhamento e complicações. O critério para a inclusão dos prontuários na amostra foram de apresentarem fratura de mandíbula, com preenchimento completo de informações e de possuírem o Termo de Consentimento Livre e Esclarecido. Como critérios de exclusão, foram desconsiderados os prontuários com preenchimento incompleto das informações e que não possuiam o Termo de Consentimento Livre e Esclarecido assinado. Os dados coletados por um único examinador foram transportados para uma planilha eletrônica utilizando o programa Microsoft Excel sendo realizada neste momento uma análise descritiva dos resultados obtidos. Tabelas e gráficos foram utilizados para a apresentação e interpretação destes dados. Concluimos que houve prevalência do gênero. / The aim of this study was to retrospectively analyse four hundred and eighty-nine patients files presenting fractures of the mandibular bone, incident from attendances at the Department of Traumatology and Maxillofacial Surgery, from the School of Dentistry of Ribeirão Preto (FORP/USP) during the period between August 2002 and July 2012. The analysis was directed through population data variables such as age, gender, race and profession. Imaging tests requested, addictions, etiology of trauma, signs and symptoms, fractures classification, associated fractures, approach, treatment, time to surgical intervention and hospitalization, apart from follow-up period and complications were also analyzed. The criterion for inclusion of records in the sample were experiencing jaw fracture with complete filling of information and having the Term of Consent. Exclusion criteria were disregarded the charts with incomplete filling of information and lacked the Term of Consent signed. The data collected by a single observer were transported to a spreadsheet using Microsoft Excel program currently being conducted to a descriptive analysis of the results. Tables and graphs were used for the presentation and interpretation of these data. We conclude that there was a prevalence of male gender, white race, aged between 21-30 years with fractures of the left side, unilateral, etiology traffic accident. Most fractures were treated surgically, intraoral access were prevalent and complication rates were low.
3

Estudo da força de mordida, eletromiografia e mobilidade mandibular em pacientes submetidos ao tratamento cirúrgico de fraturas, isoladas da mandíbula e do complexo zigomático-orbitário / Study of bite force, electromyography and jaw mobility in patients undergoing surgical treatment of fractures, isolated from mandible and zygomatic-orbital complex

Ribeiro, Michel Campos 02 June 2010 (has links)
Este estudo avaliou a força de mordida, eletromiografia e mobilidade mandibular em pacientes submetidos à cirurgia para tratamento de fraturas que acometeram, isoladamente, a mandíbula e o complexo zigomático-orbitário. A força de mordida foi registrada por meio de gnatodinamômetro na região dos molares do lado da fratura e contra-lateral e entre os incisivos centrais. Os sinais eletromiográficos foram captados dos músculos masseteres e temporais. A mobilidade mandibular foi avaliada por mensuração, com paquímetro digital, da abertura bucal, lateralidade direita e esquerda, e na protrusão mandibular, todos em amplitude máxima. A amostra foi constituída por três grupos: Grupo 1 - Controle (sem fratura avaliação única) com 12 indivíduos; Grupo 2 - Fratura mandibular, com 8 indivíduos; Grupo 3 - Fratura do complexo zigomático-orbitário (CZO), com 5 indivíduos. As fraturas foram tratadas cirurgicamente por meio de FIR (fixação interna rígida) em todos os casos, utilizando-se acessos intra e ou extrabucais. O tempo de acompanhamento foi de 2 meses para o grupo 2 e para o grupo 3 foram 6 meses. Nas avaliações realizadas, os grupos 2 e 3, apresentaram redução da força de mordida, e elevação da atividade eletromiográfica nos períodos pós operatórios iniciais. No entanto atingiram padrão de normalidade a partir do 2º mês de pós operatório. Quanto à mobilidade mandibular, a mesma se apresentou diferentemente nos dois grupos, sendo que para o grupo 2, ela mostrou redução da amplitude de todos os movimentos mandibulares avaliados, retomando padrão de normalidade no 2º mês pós operatório. Já para o grupo 3, apenas a abertura bucal máxima mostrou-se reduzida e retomou padrão de normalidade no 1º mês pós operatório. / This study evaluated the bite force, electromyography and jaw mobility in patients undergoing surgery for treatment of fractures that attacked alone, the mandible and the zygomatic-orbital complex. The bite force was recorded by gnathodynamometer in the region of the molars on the side of the fracture and contralateral side and between the central incisors. The electromyographic signals were captured of masseter and temporal muscles. The mandibular mobility was assessed by measuring with a digital caliper, mouth opening, right and left laterality, and protruding jaw, all in the maximum amplitude. The sample consisted of three groups: Group 1 - Control (without fracture - ranking only) with 12 subjects, Group 2 - mandibular fracture, with 8 subjects and Group 3 - Fracture of the zygomatic-orbital complex (CZO), with 5 individuals. The fractures were treated surgically by means of FIR (internal fixation) in all cases, using access and intra or extraoral. The follow up was 2 months for group 2 and group 3 was 6 months. In the assessments, groups 2 and 3 had a reduction of bite force, and increased EMG activity in the early postoperative period. However reached normal range from 2 months postoperatively. The jaw mobility, it is presented differently in two groups, in Group 2, it showed a reduction in the amplitude of all mandibular movements measured, resuming normal pattern in the 2 months after surgery. As for group 3, only maximum mouth opening was reduced and resumed normal range at 1 month postoperatively.
4

Estudo biomecânico de flexão (ex-vivo) em osteotomia no diastema de mandíbulas de equinos com placas bloqueadas e implantes transdentários / Biomechanical bending study (ex-vivo) in equine osteotomized mandible fixing with locking plates and trans-dental implants

Pimentel, Luiz Fernando Rapp de Oliveira 14 December 2012 (has links)
Fraturas do diastema mandibular são cirurgicamente mais desafiadoras porque, geralmente são bilaterais, instáveis e altamente contaminadas. Como cada fratura tem características particulares e são únicas, o conhecimento de diferentes técnicas de reparo permitirá que ao veterinário escolher um método de fixação mais adequado à configuração da fratura, considerando os equipamentos disponíveis, a expertise e preferências do cirurgião. O objetivo deste estudo foi avaliar 2 técnicas de fixação de fraturas do diastema mandibular por meio da mensuração de suas características biomecânicas. Mandíbulas osteotomizadas no diastema foram divididas em 2 grupos de fixação (n=8). As mandíbulas foram fixadas com placas bloqueadas (LCP) e por meio de implantes transdentários com placas LC-DCP. Oito mandíbulas intactas (não osteotomizadas) foram submetidas aos ensaios biomecânicos como controle. As mandíbulas foram submetidas à ensaios biomecânicos de flexão até ocorrer a falha. O deslocamento angular (radianos) foi derivado a partir contínua mensuração da largura da fenda com extensometros inseridos ao redor do local da osteotomia. Foram selecionados os dados da fenda da osteotomia a 50 e 100 N.m para comparação padronizada da largura da fenda antes dos pontos de limite elástico e limite de flexão máximo, respectivamente para as 2 técnicas de fixação testadas. Rigidez (N.m/radiano), limite elástico (N.m) e limite de flexão máximo (N.m) foram determinados a partir das curvas de deslocamento angular da flexão e foram comparadas por meio do teste estatístico ANOVA com testes adicionais quando indicado. Foram obtidas imagens radiográficas pré fixação das mandíbulas. Os dentes submetidos à implantes transdentários foram submetidos à exames tomográficos e foram obtidos cortes histológicos calcificados. As cargas de resistência à flexão, de limite elástico e de limite de flexão máximo foram maiores nas mandíbulas intactas. Nas mandíbulas osteotomizadas as cargas de resistência à flexão, de limite elástico, de limite de flexão máximo e da largura da osteotomia à 50 e 100 N.m não foram significantemente diferentes (P>0,05) nas fixações com placas LCP e implantes transdentários com placas LC-DCP. Estas técnicas foram biomecânicamente similares. A fixação com placas LCP transdentários com placas LC-DCP são uma forma estável de fixação de fraturas localizadas no diastema mandibular. Em alguns casos, a cavidade pulpar (71% em dentes incisivos e 43% em dentes pré molares) foi penetrada pelos implantes transdentários. Estudos adicionais com animais vivos devem ser realizados para determinar as consequências a longo prazo do uso de implantes transdentários. / Mandibular fractures of the interdental space are surgically more demanding because they are often bilateral, unstable, and heavily contaminated. Because each fracture is unique, knowledge of the different repair techniques will allow the practitioner to choose a repair method best suited to the fracture configuration, equipment available, and the skill level and preferences of the surgeon. The aim of this study was to evaluate 2 fixation techniques for equine interdental space fractures by mensuration their biomechanical characteristics. Mandibles with interdental osteotomies were divided into 2 fixation groups (n = 8/group). Fixation techniques were the locking compression plates (LCP) and (2) Trans-Dental low contact - dynamic compression-plate fixation (Trans dental LC-DCP). Eight intact (nonosteotomized) mandibles were tested as controls. Mandibles were subjected to monotonic cantilever bending until failure. Angular displacement data (radians) were derived from continuously recorded gap width measurements provided by extensometers placed across the osteotomy site. Osteotomy gap width data (mm) at 50 and 100 Nm were selected for standardized comparison of gap width before the yield point and failure point, respectively of all constructs tested. Stiffness (Nm/radian), yield strength (Nm), and failure strength (Nm) were determined from bending moment-angular displacement curves and were compared using ANOVA with appropriate post hoc testing when indicated. Radiographs were obtained prefixation. Axial tomography and calcified histological cuts were obtained of the teeth submited to trans dental screws implant. Bending stiffness, yield, and ultimate failure loads were greatest for intact mandibles. Among osteotomized mandibles, stiffness, yield, ultimate faluire, and osteotomy gap width at 50 and 100 Nm was not significantly different (P>0,05) among LCP and trans dental LC-DCP constructs. They were biomechanically similar. LCP and trans dental LC-DCP fixation are stable form of fixation for interdental space fractures. In some cases the pulp cavity was penetrated (incisors teeth, 71% and check teeth, 43%) by trans dental implants. Additional studies with live animals must be performed to determine the long term consequences of adhibition the trans dental implants.
5

Estudo da força de mordida, eletromiografia e mobilidade mandibular em pacientes submetidos ao tratamento cirúrgico de fraturas, isoladas da mandíbula e do complexo zigomático-orbitário / Study of bite force, electromyography and jaw mobility in patients undergoing surgical treatment of fractures, isolated from mandible and zygomatic-orbital complex

Michel Campos Ribeiro 02 June 2010 (has links)
Este estudo avaliou a força de mordida, eletromiografia e mobilidade mandibular em pacientes submetidos à cirurgia para tratamento de fraturas que acometeram, isoladamente, a mandíbula e o complexo zigomático-orbitário. A força de mordida foi registrada por meio de gnatodinamômetro na região dos molares do lado da fratura e contra-lateral e entre os incisivos centrais. Os sinais eletromiográficos foram captados dos músculos masseteres e temporais. A mobilidade mandibular foi avaliada por mensuração, com paquímetro digital, da abertura bucal, lateralidade direita e esquerda, e na protrusão mandibular, todos em amplitude máxima. A amostra foi constituída por três grupos: Grupo 1 - Controle (sem fratura avaliação única) com 12 indivíduos; Grupo 2 - Fratura mandibular, com 8 indivíduos; Grupo 3 - Fratura do complexo zigomático-orbitário (CZO), com 5 indivíduos. As fraturas foram tratadas cirurgicamente por meio de FIR (fixação interna rígida) em todos os casos, utilizando-se acessos intra e ou extrabucais. O tempo de acompanhamento foi de 2 meses para o grupo 2 e para o grupo 3 foram 6 meses. Nas avaliações realizadas, os grupos 2 e 3, apresentaram redução da força de mordida, e elevação da atividade eletromiográfica nos períodos pós operatórios iniciais. No entanto atingiram padrão de normalidade a partir do 2º mês de pós operatório. Quanto à mobilidade mandibular, a mesma se apresentou diferentemente nos dois grupos, sendo que para o grupo 2, ela mostrou redução da amplitude de todos os movimentos mandibulares avaliados, retomando padrão de normalidade no 2º mês pós operatório. Já para o grupo 3, apenas a abertura bucal máxima mostrou-se reduzida e retomou padrão de normalidade no 1º mês pós operatório. / This study evaluated the bite force, electromyography and jaw mobility in patients undergoing surgery for treatment of fractures that attacked alone, the mandible and the zygomatic-orbital complex. The bite force was recorded by gnathodynamometer in the region of the molars on the side of the fracture and contralateral side and between the central incisors. The electromyographic signals were captured of masseter and temporal muscles. The mandibular mobility was assessed by measuring with a digital caliper, mouth opening, right and left laterality, and protruding jaw, all in the maximum amplitude. The sample consisted of three groups: Group 1 - Control (without fracture - ranking only) with 12 subjects, Group 2 - mandibular fracture, with 8 subjects and Group 3 - Fracture of the zygomatic-orbital complex (CZO), with 5 individuals. The fractures were treated surgically by means of FIR (internal fixation) in all cases, using access and intra or extraoral. The follow up was 2 months for group 2 and group 3 was 6 months. In the assessments, groups 2 and 3 had a reduction of bite force, and increased EMG activity in the early postoperative period. However reached normal range from 2 months postoperatively. The jaw mobility, it is presented differently in two groups, in Group 2, it showed a reduction in the amplitude of all mandibular movements measured, resuming normal pattern in the 2 months after surgery. As for group 3, only maximum mouth opening was reduced and resumed normal range at 1 month postoperatively.
6

Estudo biomecânico de flexão (ex-vivo) em osteotomia no diastema de mandíbulas de equinos com placas bloqueadas e implantes transdentários / Biomechanical bending study (ex-vivo) in equine osteotomized mandible fixing with locking plates and trans-dental implants

Luiz Fernando Rapp de Oliveira Pimentel 14 December 2012 (has links)
Fraturas do diastema mandibular são cirurgicamente mais desafiadoras porque, geralmente são bilaterais, instáveis e altamente contaminadas. Como cada fratura tem características particulares e são únicas, o conhecimento de diferentes técnicas de reparo permitirá que ao veterinário escolher um método de fixação mais adequado à configuração da fratura, considerando os equipamentos disponíveis, a expertise e preferências do cirurgião. O objetivo deste estudo foi avaliar 2 técnicas de fixação de fraturas do diastema mandibular por meio da mensuração de suas características biomecânicas. Mandíbulas osteotomizadas no diastema foram divididas em 2 grupos de fixação (n=8). As mandíbulas foram fixadas com placas bloqueadas (LCP) e por meio de implantes transdentários com placas LC-DCP. Oito mandíbulas intactas (não osteotomizadas) foram submetidas aos ensaios biomecânicos como controle. As mandíbulas foram submetidas à ensaios biomecânicos de flexão até ocorrer a falha. O deslocamento angular (radianos) foi derivado a partir contínua mensuração da largura da fenda com extensometros inseridos ao redor do local da osteotomia. Foram selecionados os dados da fenda da osteotomia a 50 e 100 N.m para comparação padronizada da largura da fenda antes dos pontos de limite elástico e limite de flexão máximo, respectivamente para as 2 técnicas de fixação testadas. Rigidez (N.m/radiano), limite elástico (N.m) e limite de flexão máximo (N.m) foram determinados a partir das curvas de deslocamento angular da flexão e foram comparadas por meio do teste estatístico ANOVA com testes adicionais quando indicado. Foram obtidas imagens radiográficas pré fixação das mandíbulas. Os dentes submetidos à implantes transdentários foram submetidos à exames tomográficos e foram obtidos cortes histológicos calcificados. As cargas de resistência à flexão, de limite elástico e de limite de flexão máximo foram maiores nas mandíbulas intactas. Nas mandíbulas osteotomizadas as cargas de resistência à flexão, de limite elástico, de limite de flexão máximo e da largura da osteotomia à 50 e 100 N.m não foram significantemente diferentes (P>0,05) nas fixações com placas LCP e implantes transdentários com placas LC-DCP. Estas técnicas foram biomecânicamente similares. A fixação com placas LCP transdentários com placas LC-DCP são uma forma estável de fixação de fraturas localizadas no diastema mandibular. Em alguns casos, a cavidade pulpar (71% em dentes incisivos e 43% em dentes pré molares) foi penetrada pelos implantes transdentários. Estudos adicionais com animais vivos devem ser realizados para determinar as consequências a longo prazo do uso de implantes transdentários. / Mandibular fractures of the interdental space are surgically more demanding because they are often bilateral, unstable, and heavily contaminated. Because each fracture is unique, knowledge of the different repair techniques will allow the practitioner to choose a repair method best suited to the fracture configuration, equipment available, and the skill level and preferences of the surgeon. The aim of this study was to evaluate 2 fixation techniques for equine interdental space fractures by mensuration their biomechanical characteristics. Mandibles with interdental osteotomies were divided into 2 fixation groups (n = 8/group). Fixation techniques were the locking compression plates (LCP) and (2) Trans-Dental low contact - dynamic compression-plate fixation (Trans dental LC-DCP). Eight intact (nonosteotomized) mandibles were tested as controls. Mandibles were subjected to monotonic cantilever bending until failure. Angular displacement data (radians) were derived from continuously recorded gap width measurements provided by extensometers placed across the osteotomy site. Osteotomy gap width data (mm) at 50 and 100 Nm were selected for standardized comparison of gap width before the yield point and failure point, respectively of all constructs tested. Stiffness (Nm/radian), yield strength (Nm), and failure strength (Nm) were determined from bending moment-angular displacement curves and were compared using ANOVA with appropriate post hoc testing when indicated. Radiographs were obtained prefixation. Axial tomography and calcified histological cuts were obtained of the teeth submited to trans dental screws implant. Bending stiffness, yield, and ultimate failure loads were greatest for intact mandibles. Among osteotomized mandibles, stiffness, yield, ultimate faluire, and osteotomy gap width at 50 and 100 Nm was not significantly different (P>0,05) among LCP and trans dental LC-DCP constructs. They were biomechanically similar. LCP and trans dental LC-DCP fixation are stable form of fixation for interdental space fractures. In some cases the pulp cavity was penetrated (incisors teeth, 71% and check teeth, 43%) by trans dental implants. Additional studies with live animals must be performed to determine the long term consequences of adhibition the trans dental implants.
7

Avaliação do uso do laser em baixa intensidade em pacientes com fraturas mandibulares – ensaio clínico controlado / Evaluation of the effect of low level laser in patients with mandibular fracture on mandibular dynamics and bite force: a clinical trial pilot study

Lauriti, Leandro 04 December 2015 (has links)
Submitted by Nadir Basilio (nadirsb@uninove.br) on 2018-06-21T18:49:26Z No. of bitstreams: 1 Leandro Lauriti.pdf: 1122104 bytes, checksum: 723249c6bdf2f01f0de75515602a5180 (MD5) / Made available in DSpace on 2018-06-21T18:49:26Z (GMT). No. of bitstreams: 1 Leandro Lauriti.pdf: 1122104 bytes, checksum: 723249c6bdf2f01f0de75515602a5180 (MD5) Previous issue date: 2015-12-04 / The aim of the present study was to perform an evaluation of the effect of low-level laser therapy (LLLT) on bite force, facial swelling, mandibular movements and pain in patients having undergone surgical treatment for mandibular fracture. The patients were divided into two groups: Group 1 – active LLLT; and Group 2 – sham LLLT. Both groups took anti-inflammatory agents postoperatively. Group 2 underwent the surgical reduction and rigid internal fixation, the use of postoperative an anti-inflammatory agent and sham LLLT with the equipment switched off. Fifteen sessions were performed using the point application methods and wavelength: 660 nm; power; 108 mW; radiant energy: 21.6 J; fluence: 21.6 J/cm2; radiance: 38197 mW/cm2; exposure time: 200 seconds per point. The active laser group received LLLT in the region of the incision and over the masseter (3 points: superior, medial and inferior) and temporal (anterior region) muscles, with five application points on each side, totaling 10 points bilaterally. The Shapiro-Wilk test was used for the analysis of the results and normal distribution was demonstrated. Thus, the Student’s t-test was used to determine inter-group differences and repeated-measures ANOVA was used to determine whether significant differences occurred at different times. The level of significance was set to 5% ( = 0.05). The findings we can see considerable improvement in the group submitted to active LLLT with regard to mandibular dynamics, a reduction in postoperative facial swelling, a reduction in pain and an increase in bite force in comparison to the sham group, which only used postoperative corticosteroids. / O objetivo deste estudo foi avaliar o efeito da LBI (laserterapia em baixa intensidade) sobre a força de mordida, edema, movimentos mandibulares e presença de dor em pacientes acometidos por fraturas mandibulares. Os pacientes foram divididos em dois grupos: Grupo 1 (LBI) e Grupo 2 (Placebo). No grupo experimental (Grupo 1), além de anti-inflamatórios no pós operatório foi aplicada a LBI. No grupo Placebo (Grupo 2) foi realizado somente o tratamento cirúrgico de redução e fixação interna rígida, o uso de anti-inflamatórios no pós-operatório e aplicação do equipamento de laser desligado. Foram realizadas um total de 15 sessões pelo método de aplicação pontual com comprimento de onda de 660nm, potência de 108 mW, energia radiante de 21,6 J, fluência de 21,6 J/cm2, irradiância de 38197 mW/cm2, durante 200 segundos por ponto. Receberam o tratamento com laser os grupos com fraturas de mandíbula, na área da incisão e nos músculos masseteres (3 pontos: superior, médio e inferior) e temporais (região anterior) em um total de 5 pontos de aplicação em cada lado, totalizando 10 pontos bilateralmente. Para análise dos resultados foi empregado o teste de Shapiro-Wilk. Como os dados apresentaram distribuição normal foi utilizado o teste t de Student para determinar as diferenças entre os grupos e o teste de ANOVA para medidas repetidas e verificar se houve diferença significante nos diferentes tempos. Adotou-se o nível de significância de 5% (=0,05). Com base nos resultados apresentados podemos verificar uma melhora considerável no grupo experimental tratado com LBI em relação a dinâmica mandibular, redução do edema facial pós-operatório, menor sintomotalogia dolorosa e aumento da força de mordida em relação aos pacientes que utilizaram apenas corticosteróides no pós cirúrgico.

Page generated in 0.0938 seconds