• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 28
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 29
  • 29
  • 29
  • 14
  • 14
  • 12
  • 6
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Desenvolvimento de placas para fixação interna rígida : estudo da resistência a compressão em fraturas simuladas de côndilo da mandíbula / Development of plates for internal fixation : study of resistance to compression fractures of mandibular condyle simulated

Celegatti Filho, Tóride Sebastião, 1966- 03 July 2013 (has links)
Orientador: Simonides Consani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-23T15:57:19Z (GMT). No. of bitstreams: 1 CelegattiFilho_TorideSebastiao_M.pdf: 4195192 bytes, checksum: e279d02d5c5aabef9927997e90717129 (MD5) Previous issue date: 2013 / Resumo: O propósito neste estudo foi desenvolver placas em forma de Y com espessuras de 0,6, 1,0 e 1,5 mm para ser usadas em fratura de colo de côndilo da mandíbula e submetê-las ao ensaio de resistência mecânica de compressão. Fo-ram desenvolvidas 10 placas em Y para cada espessura, contendo 8 furos. As placas foram confeccionadas de acordo com projeto idealizado pelo autor e fabricado pela empresa Toride Indústria e Comércio Ltda., Mogi Mirim, SP, Brasil. As placas foram confeccionadas com titânio comercialmente puro (grau ll), conforme norma ASTM F-67. Os processos para desenvolvimento das placas foram feitos em programa de desenho mecânico Solid Works. A confecção das placas seguiu a metodologia de fabricação já existente na empresa, compreendendo processo de usinagem em equipamento modelo Discovery Romi de 4 eixos, o qual mantém precisão e controle dimensional com tolerância de ± 0,10 mm. Foram também confeccionadas 30 hemi-mandíbulas do lado esquerdo, com resina de poliuretano rígido de densidade 40 a 50 PCF onde as placas foram fixadas para conter fratura simulada da cabeça do côndilo. O teste de carregamento foi executado na máquina para ensaio universal Instron, modelo 4411, aplicando carga na posição médio-lateral e ântero-posterior na cabeça do côndilo. ANOVA com 2 fatores e teste de Tukey com 5% de significância foram aplicados nos resultados. Quando a carga foi aplicada no sentido médio-lateral, a placa de maior espessura (1,5 mm) obteve a maior resistência, mas sem diferença estatística entre os deslocamentos de 5,0 e 10,0 mm. No sentido ântero-posterior, a placa com maior resistência foi a de menor espessura, seguida pela de maior espessura. Pode-se concluir que: 1 - No sentido médio-lateral, os maiores valores de resistência foram observados no deslocamento de 15 mm, exceto para as placas 0,6 e 1,5 mm com valores similares em 10 e 20 mm respectivamente; 2 - A placa com espessura de 1,5 mm foi a única que apresentou maior valor médio em todos os deslocamentos; 3 - No sentido ântero-posterior, os maiores valores de resistência foram vistos no deslocamento de 15 mm e os menores em 5 mm para todas as espessuras de placas; 4 - A placa com espessura de 0,6 mm foi a que apresentou maiores valores em todos os deslocamentos e 5 - No sentido ântero-posterior, o carregamento de 20 mm não foi alcançado / Abstract: The purpose of this study was to develop a Y plate with thicknesses of 0.6, 1.0 and 1.5 mm for use in condylar mandible fracture and submit them to the me-chanical strength testing Compression. For this study 30 plates were used for surgical containment internal, Y geometry and holes 8, 10 plates with a thickness of 0.6 10 mm plates with 1.0 mm thickness and 10 plates with thickness of 1.5 mm. This model plate was designed by the author and manufactured by Toride Industry e Comercio Ltda., Mogi Mirim, Brazil. The plates were made from commercially pure titanium (grade II), according to ASTM F-67. The processes for developing the plates were made in program Solid Works mechanical design engineering company by Toride, following the procedures of the project. The making of the plates followed the methodology in an existing manufacturing company, including process equipment machining model Romi Discovery of 04 axes, which keeps ac-curacy and dimensional control with a tolerance of ± 0.10 mm, required by the quality system of the company Toride. Were prepared hemi-jaws 30 on the left side with hard polyurethane resin density 40-50 PCF where the plates were fixed. The load test was run on the test equipment universal Servohidráulico Instron Model 4411 (Instron Corp., Norwood, MA.), and will have to evaluate the strength of plates attached Hemi-mandibles applying the force in mid-lateral position, and the force applied at Antero-posterior position, were predetermined three shifts, ob-taining values of average load in the three, Statistical analysis of variance by ANOVA used 02 factors, the Tukey test at 5% significance level was applied. When the load was applied in the medial-lateral plate of greater thickness (1.5 mm) gave the highest strength, but no statistical difference in displacement of 5.0 and 10.0 mm. Antero-posterior direction on the plate was the biggest strength of thinner, following the greater thickness. It can be concluded that: 1 - In the medial - lateral direction, the highest values of resistance were observed in the displacement of 15 mm, except for the 0.6 and 1.5 mm plates with similar values in 10 and 20 mm respectively; 2 - A plate with thickness of 1.5 mm was the one with the highest average value on all shifts; 3 - In the antero-posterior direction, the highest values of resistance were seen in the displacement of 15 mm and 5 mm in the minors for all thicknesses of plates; 4 - A plate with thickness of 0.6 mm showed the highest values in all shifts and; 5 - In the antero-posterior direction, the loading of 20 mm was not achieved / Mestrado / Materiais Dentarios / Mestre em Materiais Dentários
12

Análise topográfica através de análise metalográfica de placa e parafuso do sistema 2,4mm com sistema de travamento em três diferentes quantidades de ciclos de autoclavagem / Topographical analysis via metallographic analysis of plate and screw system of 2.4 mm locking system in three different cycles of autoclaving

Santos, Saulo Ellery, 1983- 03 January 2012 (has links)
Orientador: Roger William Fernandes Moreira, Marcelo Marotta Araujo / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-20T05:38:06Z (GMT). No. of bitstreams: 1 Santos_SauloEllery_D.pdf: 17593176 bytes, checksum: 114d3bc8c68cd4b332a698a936817b96 (MD5) Previous issue date: 2012 / Resumo: Sistemas de fixação interna estável são utilizados em cirurgia óssea, sejam elas de fraturas ou osteotomias programadas, podem ser submetido a múltiplos procedimentos de esterilização procedimentos antes da implantação em um ambiente de acolhimento. Durante a sua utilização eventualmente o cirurgião depara-se com intercorrências cirúrgicas como quebra da placa durante a dobragem ou quebra de parafusos durante sua inserção e isso de fato ocorre na prática clínica. O objetivo do autor neste estudo foi avaliar se o processo repetido de autoclavagens influencia nas características de dureza e microscópicas das placas e parafusos do sistema 2,4mm "locking". A amostra foi dividas em placas: grupo I (0) controle, grupo II submetido a 20 processos de autoclavagem e grupo III submetido a 60 processos de autoclavagem. Os parafusos foram divididos da mesma forma: grupo I (0), grupo II (20) e grupo III (60). Após o preparo do corpo de provas foram realizados os testes de dureza e avaliação em microscopia da microestrutura. Encontrou-se uma média de valores de dureza de 180,2; 183,8 e 171,8 Vickers respectivamente para os grupos I, II e III das placas (p=0,497) e os valores médios de 328,8; 340,8 e 355,3 Vickers respectivamente para os grupos I, II e III dos parafusos (p=0,283). Na análise microscópica tanto dos parafusos quanto das placas observou-se imagens em 500x que revelaram a microestrutura do material, com grânulos em conformações diferentes, de acordo com a margem analisada, observam-se ainda formação de maclas, principalmente na margem interna, o que pode ser decorrente de força de pressão/cisalhamento durante processo de usinagem, mas sem diferenças entre os grupos. Baseado nos resultados obtidos nas amostras estudadas, observou-se que o processo repetido de autoclavagens não alterou significativamente as características de dureza e microscópicas do material analisado / Abstract: Stable internal fixation systems are used in bone surgery, either fractures or osteotomies, It can be submitted to multiple procedures sterilization procedures before implantation. During its use eventually the surgeon is confronted with surgical complications such as rupture of the plate during bending or breakage of screws during insertion, and this in fact occurs in clinical practice. The aim of study was to evaluate if the repeated autoclaving influences the characteristics of hardness and microscopic of plates and screws of 2.4 mm system "locking". The sample was divided into plates: group I (0) control, group II was subjected to 20 sterilization processes and group III underwent 60 procedures for autoclaving. The screws were divided equally: group I (0), group II (20) and group III (60). After preparing the sample, and were carried out hardness testing and evaluation in the microscopy of microstructure. We found a mean hardness value of 180.2, 183.8 and 171.8 Vickers respectively for the groups I, II and III of the plates (p = 0.497) and mean values of 328.8, 340.8 and 355.3 Vickers respectively for the groups I, II and III of the screws (p = 0.283). Microscopic analyzes of both screws and the plates was observed images 500x revealed that the microstructure of the material, with granules in different conformations in accordance with the margin analyzed, there are still forming twinned, especially in the inset, which may be due to pressure force / shear during the machining process, but no differences between groups was observed. Based on the results obtained in all samples, it was observed that the repeated autoclaving does not significantly alter the characteristics of the material hardness and microscopic examination / Doutorado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Doutor em Clínica Odontológica
13

Avaliação in vitro do uso de uma miniplaca convencional e locking, de 4 e 7 furos, para tratamento das fraturas de ângulo mandibular

Ribeiro Júnior, Paulo Domingos [UNESP] 06 May 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:06Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-05-06Bitstream added on 2014-06-13T19:20:06Z : No. of bitstreams: 1 ribeirojunior_pd_dr_araca.pdf: 475855 bytes, checksum: 25027ddf9644c9757d0a760d4ed4ca58 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Este estudo avaliou in vitro a influência do tipo de miniplaca (convencional ou locking) e do número de parafusos instalados no segmento ósseo distal e proximal para a promoção da estabilidade óssea e resistência da osteossínteses pelo método Champy, utilizada para o tratamento de fraturas de ângulo mandibular. Sessenta hemi-mandíbulas de poliuretano, com consistência similar ao osso mandibular, foram divididas em 4 grupos (n=15) e seccionadas na região de ângulo mandibular simulando uma fratura. Os segmentos ósseos foram fixados por diferentes tipos de miniplacas usando sistema 2.0- mm e parafusos monocorticais de 2.0 x 6.0mm. Nos grupos 1 e 2, dois parafusos convencionais (G1) ou locking (G2) foram instalados em cada segmento ósseo usando respectivamente miniplacas retas convencionais e locking; Nos grupos 3 e 4, três parafusos convencionais (G3) ou locking (G4) foram instados no segmento ósseo proximal e quatro parafusos convencionais (G3) ou locking (G4) foram instalados no segmento distal, usando uma miniplaca convencional (G3) e locking (G4) de sete furos, reta. As hemi-mandíbulas foram submetidas a um teste de compressão utilizando uma máquina universal de ensaio INSTRON até que houvesse um distanciamento entre os segmentos ósseos de 4 mm, seja no sentido horizontal ou vertical. Os dados registrados foram submetidos à avaliação estatística pelo método ANOVA e teste de Tukey utilizando um nível de significância de 1%. As miniplacas locking ofereceram maior resistência ao teste de compressão do que as miniplacas convencionais (p<0.01). Porém, não existiu diferença entre o uso de miniplacas de 7 ou 4 furos (p>0.01). Apesar de não estatisticamente significante os resultados numéricos sugeriram que as miniplacas locking longas oferecem maior resistência ao teste de compressão que as miniplacas locking curtas. / This study evaluated in vitro the influence of the type of miniplate (conventional or locking) and the number of screws installed in the proximal and distal segments on the stability and resistance of Champy’s osteosynthesis in mandibular angle fractures. Sixty polyurethane hemimandibles with bone-like consistency were randomly assigned to 4 groups (n=15) and sectioned in the mandibular angle region to simulate fracture. The bone segments were fixed by different osteosynthesis methods using 2.0-mm miniplates and 2.0 x 6 mm monocortical screws: Groups 1 and 2- Two conventional (G1) or locking (G2) screws were installed in each bone segment using either a conventional (G1) or a locking (G2) straight miniplate; Groups 3 and 4- Three conventional (G3) or locking (G4) screws were installed in the proximal segment and four conventional (G3) or locking (G4) screws were installed in the distal segment using a either a conventional (G3) or a locking (G4) 7-hole straight miniplate. The hemimandibles were loaded in compressive strength in an Instron machine until a 4-mm displacement occurred between the segments either vertically or horizontally. Data were analyzed statistically by ANOVA and Tukey’s test at 1% significance level. The locking plate/screw systems provided significantly greater resistance to displacement under compressive load than the conventional plate/screw systems (p<0.01). However, no statistically significant difference was found between 7-hole and 4-hole miniplates (p>0.01). In conclusion, the locking miniplates offered more resistance than conventional miniplates and long locking miniplates provided greater (number results) bone stability compared to short ones.
14

Placas ósseas confeccionadas a partir de diáfise cortical equina na osteossíntese femoral em coelhos = Bone plates produced from equine cortical bone in rabbits femoral osteosynthesis / Fernando Pinheiro Milori ; orientador, Antônia Maria do Rocio Binder do Prado / Bone plates produced from equine cortical bone in rabbits femoral osteosynthesis

Milori, Fernando Pinheiro January 2010 (has links)
Dissertação (mestrado) - Pontifícia Universidade Católica do Paraná, São José dos Pinhais, 2010 / Inclui bibliografias / A evolução tecnológica tem possibilitado o desenvolvimento e o aperfeiçoamento de novos materiais para implantes. Apesar dos fundamentais benefícios providos pelos dispositivos ortopédicos, complicações decorrentes de corrosão, degradação, infecção, além / Actually, technological advances have contributed to the development and improvement of new materials for implants. Despite the fundamental benefits provided by orthopedic materials, complications resulting from corrosion, degradation, infection, and othe
15

Caracterização físico-química, morfológica, análise mecânica e de elementos finitos 3D, de diferentes placas e parafusos metálicos e técnicas de fixação interna, empregadas em fraturas de ângulo mandibular

Guastaldi, Fernando Pozzi Semeghini [UNESP] 26 April 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-04-26Bitstream added on 2014-06-13T20:21:53Z : No. of bitstreams: 1 guastaldi_fps_dr_araca.pdf: 2507066 bytes, checksum: a269643c19104677e351a0d2217af1fc (MD5) / Proposição: Realizar uma caracterização físico-química, morfológica e comparar o comportamento mecânico de uma liga experimental de Ti-Mo, ao sistema de fixação análogo à base de Ti, em fraturas de ângulo mandibular, favoráveis ao deslocamento. Adicionalmente, análises de elementos finitos 3D foram realizadas para avaliar o padrão de distribuição de tensões nas placas e nos parafusos. Material e Método: Vinte e oito réplicas de mandίbulas de poliuretano foram usadas e uniformemente seccionadas na região do ângulo mandibular esquerdo. Estas foram divididas em 4 grupos considerando o material das placas e as técnicas de fixação interna: grupo Eng 1P, uma placa (zona de tensão da mandίbula) e 4 parafusos de 6 mm de comprimento; grupo Eng 2P, duas placas (uma na zona de tensão da mandίbula e a outra na zona de compressão), a primeira fixada com 4 parafusos de 6 mm de comprimento e a segunda com 4 parafusos de 12 mm de comprimento, sendo todo o material de fixação do sistema 2.0-mm. Os mesmos grupos foram criados para a liga Ti-15Mo. Cada grupo foi submetido a uma carga vertical linear no primeiro molar. As médias e os desvios-padrão foram comparados para avaliação estatίstica (ANOVA; p < .05). Adicionalmente, foi construído um modelo de elementos finitos 3D considerando as mesmas variáveis para avaliar as tensões equivalentes de von Mises (σvM) nas placas e nos parafusos. Resultados: Diferença estatisticamente significativa (p < .05) foi encontrada quando foi realizada a comparação entre ambas as técnicas de fixação (1 e 2 placas), independentemente do material das placas (cpTi and Ti-15Mo). Quando considerado os valores das tensões equivalentes de von Mises (σvM) para... / Purpose: Perform a physico-chemical and morphological characterization and compare the mechanical behavior of an experimental Ti-Mo alloy to the analogous metallic Ti-based fixation system, for mandibular angle fractures, favorable to displacement. Additionally, finite element analysis was performed to assess the stress distribution in the plates and screws. Material and Method: Twenty eight polyurethane mandible replicas were used and uniformly sectioned on the left mandibular angle. These were divided into 4 groups considering the material of the plates and the internal fixation techniques: group Eng 1P, one 2.0-mm plate (tension zone of the mandible) and 4 screws 6 mm long; group Eng 2P, two 2.0-mm plates (one in the tension zone of the mandible and the other in the compression zone), the first fixed with 4 screws 6 mm long and the second with 4 screws 12 mm long. The same groups were created for the titanium alloy (Ti-15Mo). Each group was subjected to linear vertical loading at the first molar. Means and standard deviations were compared with respect to statistical significance (ANOVA; p < .05). Additionally, an three-dimensional finite element model reproducing the characteristics of the specimens used in the mechanical tests were created to evaluate the von Mises equivalent stress (σvM) in the plates and screws. Results: Statistically significant difference (p < .05) was found when the comparison between both internal fixation techniques (1 and 2 plates) was performed, regardless the materials of the plates (cpTi and Ti-15Mo). When considering the von Mises equivalent stress (σvM) values for the comparison between both groups (Eng and Ti-15Mo) with 1 plate, an decrease of 10.5% in the plate and an decrease of 29.0% in the screws... (Complete abstract click electronic access below)
16

Osteossíntese minimamente invasiva com placa bloqueada nas fraturas de tíbia em cães

Rosa-Ballaben, Nátalie Massaro [UNESP] 27 June 2014 (has links) (PDF)
Made available in DSpace on 2014-11-10T11:09:44Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-06-27Bitstream added on 2014-11-10T11:58:34Z : No. of bitstreams: 1 000790811.pdf: 1696564 bytes, checksum: 027b168593fdf7d048ba6f9ee1d8823d (MD5) / Avanços na compreensão da biologia óssea e das complicações das fraturas têm levado a modificações na abordagem da fixação interna das mesmas, sendo a osteossíntese minimamente invasiva com placa (MIPO) uma das mais recentes evoluções para o manejo biológico das fraturas. O objetivo do presente estudo foi avaliar o uso de placas bloqueadas aplicadas de forma minimante invasiva em fraturas de tíbia de cães. Foram utilizados 10 cães apresentando fraturas de tíbia, de idades e raças variadas. Os animais foram avaliados quanto a deambulação, intensidade do edema, exames radiográficos, e densitometria óptica nos períodos 0, 15, 30, 60, 90 e 120 dias de pós-operatório. Após 15 dias de pós-operatório 80% dos cães já utilizavam o membro ao caminhar e apresentavam formação de edema leve a ausente no membro operado. Após 30 dias de pós-operatório 100% dos cães já apoiavam o membro ao caminhar e não apresentavam formação de edema no membro. Todos os pacientes apresentaram sinais radiográficos e densitométricos de início de consolidação óssea após 15 dias de pós-operatório. O tratamento de fraturas de tíbia por meio da MIPO é uma alternativa eficaz, resultando em utilização precoce do membro e união clínica efetiva, e pode ser realizada sem uso de intensificadores de imagem / Advances in the comprehension of the bone healing and complications of the treatment of the fractures have been changed some concepts. Less invasive procedures have been advocated. A minimally invasive plate osteosynthesis (MIPO) is one of the best ways to avoid over tissue damage. The aim of this study was to evaluate the use of MIPO in tibial fractures in dogs. Ten dogs presenting a tibial fracture were used. Deambulation, swelling intensity and radiographic changes were evaluated preoperatively, just after the procedure and at 15, 30, 60, 90 e 120 days postoperatively. Six of 10 (60%) dogs were able to walk at 15 days postoperatively with slight swelling and mild lameness. Two of 10 (20%) presented normal walking at the same period. At 30 days postoperatively all dogs were able to walk normally. Six of them were not lame and 9 did not present swelling. Bone healing could be followed by radiographic evaluation. All dog presented initial radiographic signs of bone healing after 15 days postoperatively. Two of 10 showed clinical union at this time. In five of 10 (50%) clinical union could be observed after 60 days. The treatment of tibial fractures by MIPO is an effective alternative resulting in early and effective clinical union and can be performed without the use of image intensifiers
17

Avaliação do comportamento mecânico de três diferentes tipos de osteossíntese em fratura de côndilo mandibular: análise por elementos finitos 3D

Jesus, Giorge Pessoa de [UNESP] 27 September 2013 (has links) (PDF)
Made available in DSpace on 2014-12-02T11:16:37Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-09-27Bitstream added on 2014-12-02T11:21:07Z : No. of bitstreams: 1 000794326.pdf: 1135127 bytes, checksum: cb4342f5f8184e0cb349451bdf351409 (MD5) / O uso de duas miniplacas retas é o método mais indicado na literatura, para se prevenir complicações no tratamento de fraturas de côndilo. Diferentes estudos evidenciam que a estabilidade da osteossíntese é relacionada com as tensões mecânicas que ocorrem na região do côndilo, geradas pelos músculos da mastigação. O objetivo neste estudo foi avaliar o comportamento mecânico de três métodos de osteossíntese, por meio de um modelo mandibular de elementos finitos (MEF), comparando a distribuição de tensões e o comportamento dos materiais nas fraturas subcondilares baixas. Simulou-se uma fratura transversa subcondilar baixa, no modelo mandibular e a adaptação dos materiais de osteossíntese para a fixação da fratura. Três métodos de fixação com placas de titânio foram testados: 1) duas placas retas; 2) uma placa lambda e 3) uma placa trapezoidal. Os resultados mostraram que os métodos de osteossíntese proporcionam uma boa rigidez ao sistema de fixação, com pouco deslocamento na linha de fratura. Apesar disto, com a intensidade da força aplicada, todos os modelos estariam sujeitos a falhas, pois apresentaram valores de tensão de von Mises muito elevados. Comparando o desempenho dos três modelos de placas testados, observou-se que, a placa lambda se comportou melhor, havendo uma distribuição das tensões de von Mises sobre o material de fixação e tensão máxima principal sobre o osso mais homogênea. / The use of two straight plates is the most indicated in literature, to prevent the subcondilar fractures complications. Different studies have highlighted that the osteosynthesis stability is related to the mechanical stresses that occur in the region of the condyle, generated by the chewing muscles. This study evaluated the biomechanical behavior of three methods of fixation, through a mandibular finite element model (FEM), comparing the stress distribution and behavior of materials in low subcondilar fractures. A transverse fracture was simulated in the mandibular model and on adapting osteosynthesis materials for fracture fixation. Three methods of fixations using titanium plates were tested: two straight plates; one lambda plate and; one trapezoidal plate. The results showed that the method of osteosynthesis provides a good stiffness on the fixation system with little displacement at the fracture line. Nevertheless, by the intensity of the applied force, all models would be subject to failure, because they presented very high stress values. Comparing the performance of the three plate’s models tested, it was observed better behaviors for the lambda plate, with a more homogeneous distribution of von Mises stresses on the osteosynthesis devices and maximum principal strain over the bone.
18

Caracterização fenotípica e genotípica de bactérias recuperadas de implante ortopédico de conjunto placa-parafuso e parafuso de aço inoxidável austenítico após remoção cirúrgica

Santos, Cássio Antonio Lanfredi dos [UNESP] 29 August 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:20Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-08-29Bitstream added on 2014-06-13T20:56:14Z : No. of bitstreams: 1 santos_cal_me_arafcf_parcial.pdf: 117464 bytes, checksum: 13283cebdcbc3d9085c0801450c381fd (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Universidade Estadual Paulista (UNESP) / A maioria dos casos de fraturas ósseas é utilizada nas cirurgias, implantes ortopédicos de osteossíntese (placa-parafuso e parafusos) confeccionados em aço inoxidável austeníticos, devido à sua baixa relação custo-benefício. As infecções associadas aos implantes de osteossintese estão relacionadas com o crescimento de microrganismos em biofilmes, resultando em um processo infeccioso de difícil erradicação. O objetivo do estudo foi identificar os microrganismos recuperados do conjunto metálico placaparafuso e parafusos após remoção cirúrgica, avaliar a capacidade de aderência dos microrganismos, verificar a viabilidade celular, caracterizar genotipicamente os isolados Gram-positivos e detectar a resistência aos antimicrobianos. Os conjuntos placa-parafuso e parafusos de aço inoxidável austenítico ASTM F138/F139 e ISO NBR 5832-1/9 foram transportados em bolsa de polietileno para o Laboratório de Microbiologia Clínica. Os implantes foram lavados em solução tampão fosfato-salino, armazenados em bolsa contendo solução Ringer e submetidos ao banho ultrassônico em freqüência de 40±2 kHz por 5 minutos. O fluido sonicado foi transferido para tubos Falcon e centrifugado a 3.000g durante 20 minutos. O sedimento foi resuspendido em nova solução Ringer, homogeneizado por vortex e 10μL semeados em ágar Sangue de carneiro 5%, MacConkey e Sabouraud. Os meios foram incubados em diferentes condições de temperatura por 7 a 14 dias para recuperação de microrganismos. O perfil de resistência dos isolados foi obtido de acordo com CLSI 2011. Para análise da viabilidade celular foi utilizado o kit Live/Dead e microscópio de fluorescência... / The majority of cases of bone fractures is used in surgery, internal fixation of orthopedic implants (screw-plate and screws) manufactured in austenitic stainless steel due to its low cost-benefit. Infections associated with implant fixation are related to the growth of microorganisms in biofilms, resulting in an infection difficult to eradicate. The objective of study was to identify the microorganisms recovered from the set screwplate and screws metallic after surgical removal, evaluate the capacity of adherence of microorganisms, check the cell viability and characterize the isolates genotypically Gram-positive and detect antimicrobial resistance. The sets screw-plate and screws of austenitic stainless steel ASTM F138/F139 and ISO NBR 5832-1/9 were transported in polyethylene bag to the Laboratory of Clinical Microbiology. The implants were washed in phosphate buffered saline solution, stored in bags containing Ringer's solution and submitted to ultrasonic bath at a frequency of 40 kHz ± 2 for 5 minutes. The sonicate fluid was transferred to falcon tubes and centrifuged at 3.000g for 20 minutes The new sediment was re-suspended in Ringer's solution, homogenized by vortex and 10μL seeded agar 5% sheep blood, MacConkey and Sabouraud. The media were incubated at different temperatures for up to 7 days for growth of CFU mL-1. The resistance profile of the isolates was obtained according to CLSI 2011. For analysis of cell viability kit was used for Live/Dead and fluorescence microscope. After microbiological analysis the isolation was observed in some samples of polymicrobial implants. The data obtained showed that bacteria were the most isolated coagulase-negative... (Complete abstract click electronic access below)
19

Avaliação do seio maxilar após fratura do complexo zigomático-maxilar tratado com fixação interna rígida em dois pontos: estudo radiográfico em humanos

Kayatt, Fernando Esgaib [UNESP] 06 August 2002 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:41Z (GMT). No. of bitstreams: 0 Previous issue date: 2002-08-06Bitstream added on 2014-06-13T19:50:41Z : No. of bitstreams: 1 kayatt_fe_me_araca.pdf: 1754439 bytes, checksum: e4d89ad0bd72df4dc5b0274e0a5e3695 (MD5) / O complexo zigomático maxilar é a segunda área da face mais atingida por injúrias, superada apenas pelos ossos nasais. É elemento essencial na configuração da face, uma vez que é a principal estrutura formadora do terço médio facial. É importante na biomecânica, está situado entre o víscero e o neurocrânio, desempenha papel fundamental na absorção e escoamento das forças de mastigação através dos pilares de reforço e sustentação. Nesse contesto encontra-se o seio maxilar cujas funções destacamse: diminuição do peso do crânio; auxiliar a ressonância da voz, a produção e a armazenagem do muco, a umidificação do ar inspirado, a manutenção do aquecimento da fossa nasal, servir como acessório do olfato, definir o contorno facial, entre outras. Avaliamos, através de radiografias PA de Waters, 40 pacientes, sendo 20 pacientes traumatizados nessa região, que foram submetidos à fixação interna rígida em dois pontos e 20 pacientes hígidos, comparando a projeção da imagem do contorno do seio maxilar. Estas avaliações foram realizadas em um período pós-operatório superior a 6 meses. Após análise dos resultados, concluímos que baseado nos achados radiográficos e nos valores de áreas dos seios maxilares, a fixação interna rígida em dois pontos mostrou-se eficaz no tratamento das fraturas não cominutivas do complexo zigomáticomaxilar. / The ZMC is the second facial area most affected by injuries, only surpassed by nasal bones fractures. It’s an essential element in facial configuration because it’s the middle third facial main structure. It’s important biomechanical being situated between the visceral and neurocranium, develop fundamental absorving and draining of the chewing forces job, across the sustaintation and strenghten pillars. Inside this complex the maxillary sinus and its functions are: to reduce head weight, to help voice ressonance, to produce and to store mucus, to umidificate the breathen air, to maintain the nasal fossa warm, olfative accessory and to define the facial contour and others. The research was performed through PA Waters radiography; 40 patients: 20 traumatizated patients in this region, submitted to the two points IRF and 20 health patients were evaluated, comparing the image projection of the maxillary sinus and observating the stability of this kind of fixation. These evaluations were made in post-operative periods, latter 6 months. After result analysis we concluded, based radiography evidence and measurement maxillary sinus area, the two points IRF are efficient on treatment of ZMC fractures not cominutive.
20

Fixação das fraturas da sífise mandibular = avaliação mecânica em mandíbulas de poliretano / Mechanical evaluation of different techcniques for symphysis fractore fixation : an in vitro polyurethane mandible study

Vieira e Oliveira, Thalita Regina, 1981- 02 November 2011 (has links)
Orientador: Luis Augusto Passeri / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-17T14:31:09Z (GMT). No. of bitstreams: 1 Oliveira_ThalitaReginaVieirae_M.pdf: 1115745 bytes, checksum: 5dfbff585807258a186160f2079d47c9 (MD5) Previous issue date: 2011 / Resumo: Este estudo teve como objetivo avaliar, comparativamente, o comportamento mecânico de quatro diferentes métodos de fixação de fraturas de sínfise mandibular. Quarenta réplicas de mandíbulas, confeccionadas em poliuretano, foram utilizadas para o ensaio experimental. As amostras foram divididas em quatro grupos com diferentes métodos de fixação: uma miniplaca, duas miniplacas dispostas paralelamente, duas miniplacas dispostas perpendicularmente e dois parafusos inseridos pela técnica lag screw, todos do sistema de 2,0mm. Cada grupo foi submetido ao teste mecânico em uma máquina de ensaio universal, Instron 4411 (Instron Corp, Norwood, MA), recebendo uma carga vertical linear na região do primeiro molar inferior esquerdo. Os valores das cargas foram mensuradas nos deslocamentos de 1 mm, 3 mm, 5 mm e 10 mm. Os resultados foram comparados por meio da Análise de Variância (p<0.05) e do Teste de Tukey. O método que utilizou uma miniplaca mostrou o menor valor de resistência, quando comparado aos outros métodos de fixação. A técnica lag screw apresentou resistência estatisticamente maior que as duas placas paralelas, em todos os deslocamentos. As duas miniplacas perpendiculares mostraram menor resistência que a técnica lag screw, quando o deslocamento atingiu 1 e 3 mm e resistência estatisticamente semelhante nos deslocamentos de 5 e 10 mm. Entretanto, as duas miniplacas perpendiculares não apresentaram diferença estatisticamente significante em relação ao grupo das duas miniplacas paralelas. Desta forma, a técnica lag screw apresentou melhor comportamento mecânico para a fixação das fraturas de sínfise mandibular, que os demais métodos avaliados neste estudo / Abstract: The aim of this study was to evaluate comparatively the mechanical behavior of 4 different internal fixation methods for mandibular symphysis fractures. Forty polyurethane mandible replicas were used. They were divided in to four groups with different fixation methods: 1 miniplate, 2 parallel miniplates, 2 perpendicular miniplates, 2 lag screws, all of them of a 2.0mm system. Each group was subjected to linear vertical loading at the molar region by an Instron 4411 servohydraulic mechanical testing unit (Instron Corp, Norwood, MA). Load values were measured at 1 mm, 3 mm, 5 mm, and 10 mm of displacement. Means and standard derivations were compared for statistical significance using a variance analysis (p < .05) and compared by the Tukey test. The one 2.0-mm miniplate showed the lowest load scores when compared with other fixation methods. The two 2.0-mm lag screw technique showed higher resistance statistically significant in comparison with two 2.0-mm parallel miniplates for all displacements. The two 2.0-mm perpedicular miniplates showed lower resistance than two 2.0-mm lag screw technique when the displacement was 1 and 3 mm, and statiscally similar results at 5 and 10 mm of displacement. However, the two 2.0-mm perpendicular miniplates group was not statiscally different from the two 2.0-mm parallel miniplates group. The lag screw technique showed better mechanical behavior for fixation of symphyseal fractures than the other methods when subjected to linear vertical loading at the molar region / Mestrado / Fisiopatologia Cirúrgica / Mestre em Ciências

Page generated in 0.0845 seconds