• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 34
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 2
  • 1
  • Tagged with
  • 37
  • 37
  • 29
  • 17
  • 17
  • 12
  • 7
  • 7
  • 6
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Osteossíntese de tíbia com uso de fixador esquelético externo conectado ao pino intramedular tie-in em cães

Dias, Luis Gustavo Gosuen Gonçalves [UNESP] 28 June 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:42Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-06-28Bitstream added on 2014-06-13T19:09:49Z : No. of bitstreams: 1 dias_lggg_me_jabo.pdf: 944031 bytes, checksum: 45badb9ad93152b592ba2aca41808c08 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A incidência de fratura de tíbia em cães representa 21% das que ocorrem nos ossos longos. Vários métodos são utilizados nas osteossínteses deste osso, tais como: pinos intramedulares; fixadores esqueléticos externos; placas ósseas e; associações entre eles. O método usado foi uma modificação da configuração denominada tie-in, na qual um PIM é conectado externamente a pinos de Schanz ou parafusos de aço inoxidável fixados com metil-metacrilato. O PIM é introduzido através de um orifício confeccionado na face medial da tíbia, próximo à crista tibia!. A configuração foi utilizada em 21 cães com fratura de tíbia atendidos no Hospital Veterinário do Câmpus da UNESP de Jaboticabal-SP. Os animais foram avaliados clínica e radiograficamente, no período pré e pós-operatório imediato e a cada 30 dias, até completar quatro meses. Os animais recuperaram, clinicamente, a função do membro no período médio de 11 dias após a cirurgia. Nove animais tiveram a configuração dinamizada, por meio da desconexão do PIM; remoção do PIM ou dos implantes de fixação e retirada dos implantes de fixação e manutenção do PIM. Radiograficamente verificou-se consolidação óssea em média de 76 dias de pós operatório, e apenas um animal apresentou não-união. A configuração tie-in mostrou se eficaz como método de osteossíntese em fraturas tibiais de cães. / The incidence of tibial fractures in dogs assumes 21 % of ali fractures that occur in long bones. Several methods are used in the osteosynthesis, of these fractures like external skeletal fixator, bone plates and associated techniques. The aim of this study is to describe the method and perform a radiographic and clinical evaluation of a group of 21 dogs with tibial fractures from the veterinary teaching hospital of the UNESP SÃO PAULO STATE UNIVERSITY- CAMPUS OF JABOTICABAL. The used method was a modification of the termed tie-in configuration, in that an IMP was connected externally with Schanz pins or stainless steel screws fixed together with methylmethacrylat. The pin was applied through hole on the medial tibia near the tibial crest. Clinical and radiographic evaluations were performed in pre-and post-operatory period and at 30, 60, 90 and 120 days. Animais recovered the function of the affected limb in a mean period of 11 days afier the surgery. Nine dogs underwent dynamization through: a) IMP disconnection, b) IMP or, c) fixation pins takeout and d) fixation pins takeout and maintenance of the IMP. Radiographicaly, the fracture union occurred in 20 dogs, in a mean period of 76 days; non-union was observed in only one dog. T~erefore, the tie-in modificated frame configuration showed efficacy as a method of osteosynthesis in tibial fractures of dogs.
12

Estudo comparativo do Titânio versus Polímero vegetal para fixação interna rígida de fraturas orbitárias de coelhos

Nunes, Elifas Levy [UNESP] 06 December 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:30:23Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-12-06Bitstream added on 2014-06-13T19:00:25Z : No. of bitstreams: 1 nunes_el_dr_botfm_prot.pdf: 2705473 bytes, checksum: cb2a12239895cd0f0391a25351fea181 (MD5) / Nas últimas décadas, os materiais utilizados para reparações ósseas de estruturas faciais tiveram um aprimoramento que muito facilitou a fixação interna rígida. Entretanto, este campo permanece aberto para as pesquisas até os dias atuais, uma vez que não se tem ainda o material ideal para este fim. Objetivo: avaliar a reparação de fraturas da parede orbitária usando a fixação interna rígida com miniplacas de titânio e de polímero vegetal comparando-as. Material e método: foi realizado um estudo experimental, prospectivo, na Faculdade de Medicina de Botucatu, no qual foram utilizados 45 coelhos albinos, submetidos a fratura do assoalho da órbita e divididos em três grupos especiais... / In the last few decades, the advances in material used for repairing facil bone fractures have greatly improved internal rigid fixing. However research in this area remains open as there still no ideal material. Objective: to evaluate the repair of orbital wall fractures with internal rigid fixings comparing mini titanium and reabsorbable vegetal polymer plates... (Complete abstract, click eletronic address below)
13

Tratamento das fraturas com traço simples da diafise do femur, com tecnica minimamente invasiva e placa em onda / Treatment of simple femoral shaft fracture with minimally invasive technique and wave plate

Angelini, Alessandro Janson 31 August 2006 (has links)
Orientador: William Dias Belangero / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-08T02:22:20Z (GMT). No. of bitstreams: 1 Angelini_AlessandroJanson_D.pdf: 8473233 bytes, checksum: 3996290e908ef6f361b3a4bf25baf1d9 (MD5) Previous issue date: 2006 / Resumo: A partir de resultados de estudos mecânicos com a placa em onda, demonstrando sua maior rigidez em montagens com algum tipo de contato cortical, surge este estudo com o objetivo de analisar o desempenho desse tipo de placa no tratamento das fraturas de traço simples da diáfise do fêmur. Foram incluídos, retrospectivamente, 57 pacientes, consecutivos, tratados com a placa em onda com técnica de osteossíntese biológica, com seguimento mínimo de um ano de pós-operatório. Obteve-se índice de consolidação de 94,74% (54 em 57 pacientes) em tempo médio de 12,88 semanas. Conclui-se que o método pode ser considerado uma alternativa às hastes intramedulares, com índices de consolidação semelhantes / Abstract: Mechanical studies with wave plates, were a higher rigidity was shown in models with cortical contact, suggested a study to analyze the use of wave plate in femoral simple shaft fractures. A consecutive series of 57 patients treated with wave plates and biological internal fixation, and a minimal follow up of 1 year after surgery. Healing occurred in 94,74% (54 of 57 patients) with an average of 12 weeks. In conclusion, this method could be considered an alternative to intramedullary nailing, with similar success rates / Doutorado / Cirurgia / Doutor em Cirurgia
14

Fraturas do terço distal do umero associada a parilisia radial : tratamento pela tecnica MIPPO / Fractures of the distal third of the humerus with palsy of the radial nerve : management using minimally-invasive percutaneous plate osteosynthesis

Livani, Bruno 23 February 2007 (has links)
Orientador: William Dias Belangero / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-09T12:25:06Z (GMT). No. of bitstreams: 1 Livani_Bruno_D.pdf: 17610036 bytes, checksum: 98624480cd2e00fcca5f2b8979f6df92 (MD5) Previous issue date: 2007 / Resumo: O tratamento das fraturas do terço distal da diáfise do úmero associadas a lesão do nervo radial ainda é assunto de controvérsia. Especialmente nesta região o nervo pode estar comprimido ou encarcerado por fragmentos ósseos. A osteossíntese com redução indireta da fratura e fixação interna, nesses casos, pode resultar em lesão nervosa permanente. O autor descreve uma técnica cirúrgica com a utilização da placa em ponte, introduzida percutaneamente nessas situações específicas. Seis pacientes foram operados evoluindo com a consolidação da fratura e a recuperação neurológica num tempo médio de 03 meses. Nessa casuística a única complicação foi um caso de infecção com fístula na cicatriz distal que resolveu completamente com a retirada do material de implante / Abstract: Fractures of the distal third of the humerus may be complicated by complete lesions of the radial nerve which may be entrapped or compressed by bone fragments. Indirect reduction and internal fixation may result in a permanent nerve lesion. The author describe the treatment of these lesions by insertion of a bridge plate using the minimally-invasive percutaneous technique. Six patients were operated on and showed complete functional recovery. Healing of the fractures occurred at a mean of 2.7 months (2 to 3) and complete neurological recovery by a mean of 2.3 months (1 to 5). In one patient infection occurred wich resolved after removal of the implante / Doutorado / Pesquisa Experimental / Doutor em Cirurgia
15

Desenvolvimento de placas para fixação interna rígida : estudo da resistência a compressão em fraturas simuladas de côndilo da mandíbula / Development of plates for internal fixation : study of resistance to compression fractures of mandibular condyle simulated

Celegatti Filho, Tóride Sebastião, 1966- 03 July 2013 (has links)
Orientador: Simonides Consani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-23T15:57:19Z (GMT). No. of bitstreams: 1 CelegattiFilho_TorideSebastiao_M.pdf: 4195192 bytes, checksum: e279d02d5c5aabef9927997e90717129 (MD5) Previous issue date: 2013 / Resumo: O propósito neste estudo foi desenvolver placas em forma de Y com espessuras de 0,6, 1,0 e 1,5 mm para ser usadas em fratura de colo de côndilo da mandíbula e submetê-las ao ensaio de resistência mecânica de compressão. Fo-ram desenvolvidas 10 placas em Y para cada espessura, contendo 8 furos. As placas foram confeccionadas de acordo com projeto idealizado pelo autor e fabricado pela empresa Toride Indústria e Comércio Ltda., Mogi Mirim, SP, Brasil. As placas foram confeccionadas com titânio comercialmente puro (grau ll), conforme norma ASTM F-67. Os processos para desenvolvimento das placas foram feitos em programa de desenho mecânico Solid Works. A confecção das placas seguiu a metodologia de fabricação já existente na empresa, compreendendo processo de usinagem em equipamento modelo Discovery Romi de 4 eixos, o qual mantém precisão e controle dimensional com tolerância de ± 0,10 mm. Foram também confeccionadas 30 hemi-mandíbulas do lado esquerdo, com resina de poliuretano rígido de densidade 40 a 50 PCF onde as placas foram fixadas para conter fratura simulada da cabeça do côndilo. O teste de carregamento foi executado na máquina para ensaio universal Instron, modelo 4411, aplicando carga na posição médio-lateral e ântero-posterior na cabeça do côndilo. ANOVA com 2 fatores e teste de Tukey com 5% de significância foram aplicados nos resultados. Quando a carga foi aplicada no sentido médio-lateral, a placa de maior espessura (1,5 mm) obteve a maior resistência, mas sem diferença estatística entre os deslocamentos de 5,0 e 10,0 mm. No sentido ântero-posterior, a placa com maior resistência foi a de menor espessura, seguida pela de maior espessura. Pode-se concluir que: 1 - No sentido médio-lateral, os maiores valores de resistência foram observados no deslocamento de 15 mm, exceto para as placas 0,6 e 1,5 mm com valores similares em 10 e 20 mm respectivamente; 2 - A placa com espessura de 1,5 mm foi a única que apresentou maior valor médio em todos os deslocamentos; 3 - No sentido ântero-posterior, os maiores valores de resistência foram vistos no deslocamento de 15 mm e os menores em 5 mm para todas as espessuras de placas; 4 - A placa com espessura de 0,6 mm foi a que apresentou maiores valores em todos os deslocamentos e 5 - No sentido ântero-posterior, o carregamento de 20 mm não foi alcançado / Abstract: The purpose of this study was to develop a Y plate with thicknesses of 0.6, 1.0 and 1.5 mm for use in condylar mandible fracture and submit them to the me-chanical strength testing Compression. For this study 30 plates were used for surgical containment internal, Y geometry and holes 8, 10 plates with a thickness of 0.6 10 mm plates with 1.0 mm thickness and 10 plates with thickness of 1.5 mm. This model plate was designed by the author and manufactured by Toride Industry e Comercio Ltda., Mogi Mirim, Brazil. The plates were made from commercially pure titanium (grade II), according to ASTM F-67. The processes for developing the plates were made in program Solid Works mechanical design engineering company by Toride, following the procedures of the project. The making of the plates followed the methodology in an existing manufacturing company, including process equipment machining model Romi Discovery of 04 axes, which keeps ac-curacy and dimensional control with a tolerance of ± 0.10 mm, required by the quality system of the company Toride. Were prepared hemi-jaws 30 on the left side with hard polyurethane resin density 40-50 PCF where the plates were fixed. The load test was run on the test equipment universal Servohidráulico Instron Model 4411 (Instron Corp., Norwood, MA.), and will have to evaluate the strength of plates attached Hemi-mandibles applying the force in mid-lateral position, and the force applied at Antero-posterior position, were predetermined three shifts, ob-taining values of average load in the three, Statistical analysis of variance by ANOVA used 02 factors, the Tukey test at 5% significance level was applied. When the load was applied in the medial-lateral plate of greater thickness (1.5 mm) gave the highest strength, but no statistical difference in displacement of 5.0 and 10.0 mm. Antero-posterior direction on the plate was the biggest strength of thinner, following the greater thickness. It can be concluded that: 1 - In the medial - lateral direction, the highest values of resistance were observed in the displacement of 15 mm, except for the 0.6 and 1.5 mm plates with similar values in 10 and 20 mm respectively; 2 - A plate with thickness of 1.5 mm was the one with the highest average value on all shifts; 3 - In the antero-posterior direction, the highest values of resistance were seen in the displacement of 15 mm and 5 mm in the minors for all thicknesses of plates; 4 - A plate with thickness of 0.6 mm showed the highest values in all shifts and; 5 - In the antero-posterior direction, the loading of 20 mm was not achieved / Mestrado / Materiais Dentarios / Mestre em Materiais Dentários
16

Análise topográfica através de análise metalográfica de placa e parafuso do sistema 2,4mm com sistema de travamento em três diferentes quantidades de ciclos de autoclavagem / Topographical analysis via metallographic analysis of plate and screw system of 2.4 mm locking system in three different cycles of autoclaving

Santos, Saulo Ellery, 1983- 03 January 2012 (has links)
Orientador: Roger William Fernandes Moreira, Marcelo Marotta Araujo / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-20T05:38:06Z (GMT). No. of bitstreams: 1 Santos_SauloEllery_D.pdf: 17593176 bytes, checksum: 114d3bc8c68cd4b332a698a936817b96 (MD5) Previous issue date: 2012 / Resumo: Sistemas de fixação interna estável são utilizados em cirurgia óssea, sejam elas de fraturas ou osteotomias programadas, podem ser submetido a múltiplos procedimentos de esterilização procedimentos antes da implantação em um ambiente de acolhimento. Durante a sua utilização eventualmente o cirurgião depara-se com intercorrências cirúrgicas como quebra da placa durante a dobragem ou quebra de parafusos durante sua inserção e isso de fato ocorre na prática clínica. O objetivo do autor neste estudo foi avaliar se o processo repetido de autoclavagens influencia nas características de dureza e microscópicas das placas e parafusos do sistema 2,4mm "locking". A amostra foi dividas em placas: grupo I (0) controle, grupo II submetido a 20 processos de autoclavagem e grupo III submetido a 60 processos de autoclavagem. Os parafusos foram divididos da mesma forma: grupo I (0), grupo II (20) e grupo III (60). Após o preparo do corpo de provas foram realizados os testes de dureza e avaliação em microscopia da microestrutura. Encontrou-se uma média de valores de dureza de 180,2; 183,8 e 171,8 Vickers respectivamente para os grupos I, II e III das placas (p=0,497) e os valores médios de 328,8; 340,8 e 355,3 Vickers respectivamente para os grupos I, II e III dos parafusos (p=0,283). Na análise microscópica tanto dos parafusos quanto das placas observou-se imagens em 500x que revelaram a microestrutura do material, com grânulos em conformações diferentes, de acordo com a margem analisada, observam-se ainda formação de maclas, principalmente na margem interna, o que pode ser decorrente de força de pressão/cisalhamento durante processo de usinagem, mas sem diferenças entre os grupos. Baseado nos resultados obtidos nas amostras estudadas, observou-se que o processo repetido de autoclavagens não alterou significativamente as características de dureza e microscópicas do material analisado / Abstract: Stable internal fixation systems are used in bone surgery, either fractures or osteotomies, It can be submitted to multiple procedures sterilization procedures before implantation. During its use eventually the surgeon is confronted with surgical complications such as rupture of the plate during bending or breakage of screws during insertion, and this in fact occurs in clinical practice. The aim of study was to evaluate if the repeated autoclaving influences the characteristics of hardness and microscopic of plates and screws of 2.4 mm system "locking". The sample was divided into plates: group I (0) control, group II was subjected to 20 sterilization processes and group III underwent 60 procedures for autoclaving. The screws were divided equally: group I (0), group II (20) and group III (60). After preparing the sample, and were carried out hardness testing and evaluation in the microscopy of microstructure. We found a mean hardness value of 180.2, 183.8 and 171.8 Vickers respectively for the groups I, II and III of the plates (p = 0.497) and mean values of 328.8, 340.8 and 355.3 Vickers respectively for the groups I, II and III of the screws (p = 0.283). Microscopic analyzes of both screws and the plates was observed images 500x revealed that the microstructure of the material, with granules in different conformations in accordance with the margin analyzed, there are still forming twinned, especially in the inset, which may be due to pressure force / shear during the machining process, but no differences between groups was observed. Based on the results obtained in all samples, it was observed that the repeated autoclaving does not significantly alter the characteristics of the material hardness and microscopic examination / Doutorado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Doutor em Clínica Odontológica
17

Comparação da resistencia ao carregamento de tres tecnicas de fixação interna rigida utilizadas no tratamento de fraturas condilares : estudo in vitro, em hemimandibulas de poliuretano

Asprino, Luciana, 1974- 18 March 2005 (has links)
Orientador: Marcio de Moraes / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-04T05:16:45Z (GMT). No. of bitstreams: 1 Asprino_Luciana_D.pdf: 2820978 bytes, checksum: 12a98cf496579afbd3ea8036f938836c (MD5) Previous issue date: 2005 / Resumo: O objetivo deste estudo foi avaliar comparativamente a resistência de três técnicas de fixação interna rígida com uso de mini placas em fratura de côndilo mandibular. Foram obtidas 80 réplicas de hemimandíbulas humanas em resina de poliuretano, sendo 20 do grupo controle. As 60 hemimandíbulas restantes foram submetidas a seccionamento simulando fratura subcondilar e em seguida fixadas com três técnicas da aplicação de placas e parafusos do sistema 2,Omm, que deram origem a seis grupos experimentais, cada um com 10 hemimandíbulas. As técnicas de fixação foram: uma placa de quatro furos com quatro parafusos de 6mm; uma placa de quatro furos com quatro parafusos de 8mm; e duas placas de quatro furos com quatro parafusos de 6mm cada. Cada sistema foi submetido ao teste de carregamento com aplicação de carga no sentido médiolateral e antero-posterior em máquina de ensaio universal Instron 4411. Foram mensurados valores de carga e deslocamento de pico. Médias e desvio padrão foram avaliados aplicando-se Análise de Variância (P<.05), verificada a significância estatística, aplicou-se o teste de Tukey com nível de significância de 5%. Tanto para o valor de carga como de deslocamento de pico, as hemimandíbulas fixadas com duas placas tiveram melhor comportamento, seguidas de uma placa com quatro parafusos de 8mm e uma placa com quatro parafusos de 6mm. Os sistemas de fixação aplicados foram mais resistentes ao carregamento no sentido antero-posterior e a aplicação de parafusos de 8mm aumentou a resistência da fixação comparado à aplicação de parafusos de 6 mm somente no teste antero-posterior. Pode-se concluir, dentro das condições testadas, que a utilização do sistema de fixação com a utilização de duas placas traz maior resistência à fixação aplicada às fraturas condilares. E, pode-se sugerir, que o uso de parafusos mais longos aumentaria a resistência da fixação aplicada à fratura de côndilo mandibular / Abstract: The aim of this study was to comparatively evaluate the resistance of three plating rigid internal fixation techniques for mandibular condylar process fractures. Eighty synthetic hemi-mandible replicas made in polyurethane were used to evaluate a control, and three mandibular condyle plating techniques using 2.0mm system plates and screws. The plating techniques were fixation with a four-hole plate and four 6-mm screws, fixation with a four-hole plate and four 8-mm screws and fixation with two four-hole plates with four 6-mm screws each. Each one was subjected to linear loading in medial to lateral and anterior to posterior directions by an Instron 4411 servo hydraulic mechanical testing unit. Load peak value and peak displacement were measured. Means and standard derivations were derived and compared for statistical significance using an analyses variance (P<.05) and compared by Tukey test. Statistically significant differences were noted between fixation groups for the different mechanical measures evaluated under the different directions of linear loading. The two-plate fixation system presented better behavior, followed by one plate with four 8-mm screws and one plate with four 6-mm screws. The employed fixation systems were more resistant to antero-posterior load and the use of 8-mm screws improved the resistance of the fixation when compared to 6-mm screws only in the antero-posterior test. Under the conditions tested the two-plate fixation system provided the most favorable mechanical behavior. We can suggest that lengthy screws can increase the stability at fixation of mandibular condylar process fractures / Doutorado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Doutor em Clínica Odontológica
18

Avaliação in vitro do uso de uma miniplaca convencional e locking, de 4 e 7 furos, para tratamento das fraturas de ângulo mandibular

Ribeiro Júnior, Paulo Domingos [UNESP] 06 May 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:06Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-05-06Bitstream added on 2014-06-13T19:20:06Z : No. of bitstreams: 1 ribeirojunior_pd_dr_araca.pdf: 475855 bytes, checksum: 25027ddf9644c9757d0a760d4ed4ca58 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Este estudo avaliou in vitro a influência do tipo de miniplaca (convencional ou locking) e do número de parafusos instalados no segmento ósseo distal e proximal para a promoção da estabilidade óssea e resistência da osteossínteses pelo método Champy, utilizada para o tratamento de fraturas de ângulo mandibular. Sessenta hemi-mandíbulas de poliuretano, com consistência similar ao osso mandibular, foram divididas em 4 grupos (n=15) e seccionadas na região de ângulo mandibular simulando uma fratura. Os segmentos ósseos foram fixados por diferentes tipos de miniplacas usando sistema 2.0- mm e parafusos monocorticais de 2.0 x 6.0mm. Nos grupos 1 e 2, dois parafusos convencionais (G1) ou locking (G2) foram instalados em cada segmento ósseo usando respectivamente miniplacas retas convencionais e locking; Nos grupos 3 e 4, três parafusos convencionais (G3) ou locking (G4) foram instados no segmento ósseo proximal e quatro parafusos convencionais (G3) ou locking (G4) foram instalados no segmento distal, usando uma miniplaca convencional (G3) e locking (G4) de sete furos, reta. As hemi-mandíbulas foram submetidas a um teste de compressão utilizando uma máquina universal de ensaio INSTRON até que houvesse um distanciamento entre os segmentos ósseos de 4 mm, seja no sentido horizontal ou vertical. Os dados registrados foram submetidos à avaliação estatística pelo método ANOVA e teste de Tukey utilizando um nível de significância de 1%. As miniplacas locking ofereceram maior resistência ao teste de compressão do que as miniplacas convencionais (p<0.01). Porém, não existiu diferença entre o uso de miniplacas de 7 ou 4 furos (p>0.01). Apesar de não estatisticamente significante os resultados numéricos sugeriram que as miniplacas locking longas oferecem maior resistência ao teste de compressão que as miniplacas locking curtas. / This study evaluated in vitro the influence of the type of miniplate (conventional or locking) and the number of screws installed in the proximal and distal segments on the stability and resistance of Champy’s osteosynthesis in mandibular angle fractures. Sixty polyurethane hemimandibles with bone-like consistency were randomly assigned to 4 groups (n=15) and sectioned in the mandibular angle region to simulate fracture. The bone segments were fixed by different osteosynthesis methods using 2.0-mm miniplates and 2.0 x 6 mm monocortical screws: Groups 1 and 2- Two conventional (G1) or locking (G2) screws were installed in each bone segment using either a conventional (G1) or a locking (G2) straight miniplate; Groups 3 and 4- Three conventional (G3) or locking (G4) screws were installed in the proximal segment and four conventional (G3) or locking (G4) screws were installed in the distal segment using a either a conventional (G3) or a locking (G4) 7-hole straight miniplate. The hemimandibles were loaded in compressive strength in an Instron machine until a 4-mm displacement occurred between the segments either vertically or horizontally. Data were analyzed statistically by ANOVA and Tukey’s test at 1% significance level. The locking plate/screw systems provided significantly greater resistance to displacement under compressive load than the conventional plate/screw systems (p<0.01). However, no statistically significant difference was found between 7-hole and 4-hole miniplates (p>0.01). In conclusion, the locking miniplates offered more resistance than conventional miniplates and long locking miniplates provided greater (number results) bone stability compared to short ones.
19

Análise morfométrica dos pedículos toracolombares de pacientes da Região Sul do Brasil / Ana Paula Massuda Valadão de Oliveira ; orientador, Luiz Roberto Aguiar

Oliveira, Ana Paula Massuda Valadão de, 1971- January 2010 (has links)
Dissertação (mestrado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2010 / Bibliografia: f. 139-150 / A instrumentação com parafusos pediculares representa um dos mais importantes avanços técnicos na cirurgia de coluna, desde sua descrição em 1959. A correta aplicação desta técnica depende muito da anatomia e morfometria dos pedículos. Vários estudos popu / First described in 1959, pedicle screw instrumentation remains one of the most important technical advances in spinal surgery. Effective application of the technique depends greatly on pedicle anatomy and morphometry, which several studies have shown to v
20

Análise da distribuição de tensões em placa estabilizadora vitrocerâmica em comparação com placa em aço inox 316L através de simulação numérica / Anderson Marcelo Petchak de Oliveira ; orientadora, Beatriz Luci Fernandes

Oliveira, Anderson Marcelo Petchak January 2010 (has links)
Dissertação (mestrado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2010 / Bibliografia: f.68-71 / Atualmente, existe uma variedade de implantes biodegradáveis disponíveis no mercado como parafusos, hastes e suturas que vem sendo usados na substituição dos implantes tradicionais fabricados em materiais metálicos que, além de necessitarem de uma segunda / Presently, there is a variety of biodegradable implants like bolts, stems and sutures available on the market that have been replacing traditional implants manufactured in metallic materials which, besides the need of a second surgery to be explanted, lib

Page generated in 0.1215 seconds