• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 24
  • 2
  • Tagged with
  • 26
  • 13
  • 9
  • 8
  • 8
  • 7
  • 7
  • 6
  • 6
  • 6
  • 4
  • 4
  • 4
  • 4
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Ansvarsfrågan vid fuktspärrsarbete i våtutrymme

Andersson, Mimmi, Andersson, Louise January 2011 (has links)
This final project is an investigation about the responsibility in rooms where the walls and floors are exposed or partly exposed to irrigation of water, as a bathroom, laundry room and WC.   The cost for all water damage is valued for 5 000 000 000 SEK each year. How is this possible with all information about the problem and good materials? Who is responsible?   Incites had been made in the subject throw reading reports and participation in courses about how to make a room mention above. Discussions have been made with workers in the trade of making the walls waterproof. The conclusion in the rapport is about who´s responsible for the damages and will pay the cost of the renovation. The responsibility is discussed between the contractor and the insurance company. If the room is waterproof system is made by the rules the insurance company pays. If it’s not the contractor is paying or if they don’t know how the carpenter is the owner has to pay for the new bathroom.
2

Fuktskador i bostadskök : En undersökning om fuktskador i kök och hur dessa kan förebyggas vid nyproduktion / Moisture damage in kitchens

Edenvind, Rickard, Eriksson, Amanda January 2011 (has links)
Moisture damage in kitchens is an area that many people believe to be irrelevant andnot a subject to concern, however the problems encountered might be larger thananticipated.The purpose of this essay is to get a view of how problematic moisture damagecurrently is as well as what can be done to prevent damage during the constructionand building of new housing.Statistics regarding moisture damage as well as several tools for damage preventionhave been studied and investigated. Industrial regulations have been reviewed tounderstand the requirements construction companies must legally follow during theconstruction and building of new kitchens. Home manufacturers and largerentrepreneurs have been contacted in order to get their point of view regarding theproblems with moisture damages in kitchens.The knowledge of moisture safe constructions is prevalent by home manufacturers,insurance companies and entrepreneurs. Despite this knowledge, the constructioncompanies predominately follow the industries regulations, which normally onlyimplement the minimum requirements.In order to get construction companies to design and build kitchens with increasedmoisture security, stricter industrial regulations might be needed to be implemented.Unlike bathrooms and laundry rooms, kitchens are not defined as a ”wet room” andthe regulations for the construction of kitchens are more lenient.It is difficult to detect water leaks in an early state and the moisture damage is usuallyextensive before it is discovered and repaired if the kitchen lacks moisture securedconstruction and water security. The most common cause of moisture damage is dueto pipe failure and, most likely in the cold water pipes where corrosion is the biggestproblem.
3

Luftläckage I Småhus : Hur de upptäcks och attityderna till dem

Olsson, Viktor January 2012 (has links)
Air tightness in new buildings has been discussed for several decades. But the knowledge in the subject is low. With tougher requirements from the Swedish government about energy consumption for a new building required competences how these shall be met. It's not only the thick mess of insulation that are important, it's also the air tightness. This report is about air leakage in Swedish houses. How these leaks can be measured/detected and what the consequences may be of them. Both theoretical and practical tips and advice will be given. The author wants to increase the knowledge in this subject for people in the Swedish building industry.
4

Fuktskador i ytterväggar på grund av vattenintrång / Moisture damage in wall contructions due to water intrusion

Kristiansson, Evguenia, Koluktsis, Antonis January 2011 (has links)
Moisture damage in buildings is a serious issue that leads to problematic consequences and high economic costs. Despite the knowledge and awareness existing about moisture problems, extensive damager still occurs today. Studies of moisture in the exterior wall constructions shows that the issue if often caused by rain and water intrusion. These kinds of problem result in major costs usually because the companies have to replace the material and structural components and also in some cases tear down large parts of the buildings. The work includes moisture theory and descriptions of four different exterior wall constructions, wood stud wall with plastered facade, exterior wall with wood facade, exterior wall with concrete, and exterior wall with brick facade. Our thesis work describes how the constructions are affected and moisture damage due to water intrusion. In this thesis, we are trying to concentrate on how water enters the structure, defects of the constructions, moisture damage, risk zones in the buildings and active to prevent moisture problems.The work also includes mail interviews with people from different companies, who have given us answer to our questions. / Fuktskador i våra byggnader är ett aktuellt problem som leder till problematiska konsekvenser och stora ekonomiska kostnader. Trots den kunskap och medvetenhet som idag finns om fuktproblem sker alltjämt omfattande skador. Vid närmare studier kring fukt i ytterväggskonstruktioner påträffas ofta problem som orsakas av regn och vattenintrång. Denna problematik orsakar kostnader, eftersom man i de flesta fall tvingas sanera, byta material och byggnadsdelar och även i vissa fall riva stora delar av byggnader. Arbetet består av en del fuktteori samt beskrivning av fyra olika ytterväggskonstruktioner, nämligen träregelvägg med putsad fasad, yttervägg med träfasad, yttervägg med betongfasad och yttervägg med tegelfasad och beskriver hur dessa påverkas och fuktskadas på grund av vattenintrång. I vårt examensarbete lägger vi stor tyngd på hur vatten tränger in i konstruktioner, brister i konstruktioner, alternativa fuktskador som uppstår, riskområden samt åtgärder. Arbetet inkluderar även mailintervjuer med personer från olika företag, som har gett oss svar på våra frågeställningar.
5

Utvärdering av ventilerade krypgrundskonstruktioner - Fuktproblem och lösningar

Johnsson, Ludvig, Lundberg, Axel January 2012 (has links)
Idag finns det en stor mängd information rörande konstruktionen av en krypgrund. Problemet är dock att en del information börjar bli föråldrad eller saknar en sammanfattning av konkreta konstruktionsval. För att förtydliga detta agerar denna rapport som en jämförelse och sammanställning av informationen för att kunna ge konkreta exempel på lösningar. Uppsatsen huvudfråga är: Hur kan de olika ventilerade krypgrunderna konstrueras för att minska risken för fuktskador?Som metod för sammanställning av rapporten har vi valt att göra en litteraturstudie. Studien tar upp källor av varierande ålder och utgångspunkt, något som vägs in i användandet av informationen. Uppbyggnaden är sådan att först förklaras de två större huvudtyperna av krypgrunder och vad fuktskador i dessa innebär. Även ett avsnitt om hur framtidens klimat kan påverka konstruktionen tas upp. Därefter kommer resultatdelen där sammanställningen av fakta finns att hitta. Resultaten visar att det finns olika tankar om hur man löser olika problem, där de som visat sig fungera bäst har valts att tas med i slutsatsen. Ett exempel kan vara att man förr i tiden valde att punktera en skyddande plastfolie i lågpunkter för att dränera ut kondensvatten. Detta visade sig dock ge upphov till andra problem, varpå rekommendationer ändrades. Detta kan man utläsa i vår resultatdel. Det har även framhävts vilka delar i konstruktionen som är mer eller mindre viktiga att tänka på, även om man skall försöka ta del av alla punkter.Författarna anser att de punkter som tas upp i slutsatsen skall beaktas om man väljer en grundkonstruktion med kryprum av ventilerad typ. Hur strikt man tar del av dessa punkter är upp till varje läsare att avgöra, samt hur läsaren uppfattar tillförlitligheten på källor och presenterade fakta. / There’s today a vast amount of information to be found which has to do with the construction of a crawlspace. The problem though is that some of this information is getting old or it is hard to find a compilation in choices of constructions. In order to make this easier, tis report will act as a comparison and compilation of information regarding solutions to certain problems. The main question in the report is: how can the different ventilated crawlspace constructions be made in order to reduce the risk of moisture damage. In order to compilate this report, the method chosen is a study of literature. This study brings up sources of different age and base, something that has been discussed in order to be able to use the information.The report is built up by first explaining the two main types of crawlspaces and what moisture damage in each of them can do. Also included is a part about climate changes and the effect of these. After that there is a compilation of results and facts to be found.The results show that there are different opinions on how to solve different problems, whereas the one, which has proven the best, has been chosen to represent the ending results. One example of this is that some people thought that it was best to puncture the vapour protecting plastic film in lower parts of the crawlspace, in order to drain water. This was to be shown to give rise to other problems, whereas the recommendation as changed. This can be read about in the results chapter. There is also a weigh-in of which components are more or less important to think about, even if one should consider all of the points.The author’s thinks that the points, which are brought up in the ending chapter, should be considered if a ventilated crawlspace-construction is to be chosen. How one chooses to interpret these points is up to anyone who reads this report, and also how the reader chose to believe in the information and the sources represented in the report.
6

Fuktsäkerhet för takkonstruktion med variabel ångspärr : Tillämpning i modulhus / Moisture control using a variable vapor barrier in roof construction : Application of modular houses

Pernefur, Joacim January 2012 (has links)
Byggbranschen har länge brottats med fuktproblem som följts av fuktskador. Nya tekniska lösningar, som skall få bukt med problemen, har inte alltid visat sig fungera. Med detta som bakgrund har en av dessa tekniska lösningar, en variabel ångspärr utretts.   Moelven Byggmodul AB tillverkar modulhus av olika slag och i detta arbete har en ny takkonstruktion hos ett av deras modulsystem undersökts utifrån ett fuktsäkerhetsperspektiv. Det ursprungliga taket använder en ventilerad luftspalt för att ventilera bort fukt som kan förekomma. Enligt tillverkaren av den variabla ångspärren behövs inte längre den ventilerade luftspalten. Genom att byta ut den ventilerade luftspalten mot ett ytterligare lager med isolering kan värmebehovet för byggnaden minska vilket bidrar till lägre driftkostnader och i sin tur minskad miljöbelastning. En variabel ångspärr har varierande ångenomsläpplighet beroende av luftens relativa fuktighet. På vintern är den relativa fuktigheten inomhus låg och då är ångspärren ångtät. Under sommaren är luftens relativa fuktighet hög och ångspärrens ånggenomsläpplighet större. En takkonstruktion med variabel ångspärr bygger på principen om uppfuktning och uttorkning hos ingående material. En fukttransport från takets uppfuktade delar till inomhusluften är möjlig då takets yttre delar värms upp av t.ex. solen. En dynamisk beräkningsmodell har konstruerats för att ta hänsyn till temperatur- och fuktförhållanden hos takets ingående material. Genom att analysera resultatet har takets fuktsäkerhet kartlagts vid placering av modulen på olika platser i Sverige. Klimatdata såsom solstrålning, relativ luftfuktighet samt temperatur har tagits med i beräkningarna.  Konstruktionens svagaste länk är spånskivan som är placerad närmast takets täckskikt. Den får problem med fukt först och blir dimensionerande. Beräkningsmodellens resultat visar att den undersökta takkonstruktionen med variabel ångspärr fungerar vid låg fuktbelastning i den södra delen av Sverige. I norra Sverige uppstår problem till följd av ett kallare klimat med lägre strålningseffekt från solen. Vid hög fuktbelastning löper den utredda takkonstruktionen en stor risk att drabbas av fuktskador, oavsett placering i landet. / The building construction industry has been struggling with moisture problems, followed by moisture damage, for a long time. New technical solutions, which purposes have been to overcome the problems, have not always been proven to work. With this in mind, one of these technical solutions, the variable diffusion barrier has been investigated.   Moelven Byggmodul produces modular houses of various types and sizes. In this study, a new type of roof construction has been investigated with focus on the ability to prevent moisture problems. The original ceiling uses a ventilated air gap in order to ventilate moisture that may occur. According to the manufacturer of the variable vapor barrier, the vented air gap will not be needed. By replacing the vented air gap with an additional layer of insulation the heating requirements of the building can be reduced which contributes to lower operating costs and reduced environmental impact.   The variable diffusion barrier has variable vapor permeability due to the relative humidity. In winter, the relative humidity is low, and the vapor diffusion barrier is vapor tight. During the summer, the relative humidity is high and the vapor permeability is increased within the diffusion barrier. A roof structure with variable diffusion barrier is based on the principle of moistening and drying of included material. A moisture transfer from the roof moistened part to the indoor air is possible when the roof's outer parts are heated by for example the sun.A dynamic calculation model has been designed to be able to analyze the temperature and moisture conditions of the roof with the module placed at different locations in Sweden.   By analyzing the results, the roofs moisture conditions have been revealed. Climate data such as solar radiation, relative humidity and temperature were taken into account.The weakest link in the structure is the chipboard which is located closest to the roof cover. By low moisture load, modeling results show that the investigated roof structure with variable diffusion barrier can be used in the southern part of Sweden. In northern Sweden, problems occur due to a colder climate with lower heat radiation from the sun. The roof structure shows a high risk of moisture damage, at high moisture load, regardless of location in Sweden.
7

Emballage för prefabricerade väggar och bjälklag, en studie i hållbarhet.

Gustavsson, Andreas January 2008 (has links)
Det här examensarbetet på kandidatnivå resulterar i en undersökning av Derome AB:s nuvarande emballage till prefabricerade väggar och bjälklag. Dagens emballage för prefabväggar och bjälklag följer inte med i utvecklingen. I arbetet undersöks möjligheterna att gå från plastemballage till pappemballage genom materialstudier och med den hållbara utvecklingen i åtanke.
8

Emballage för prefabricerade väggar och bjälklag, en studie i hållbarhet.

Gustavsson, Andreas January 2008 (has links)
<p>Det här examensarbetet på kandidatnivå resulterar i en undersökning av Derome AB:s nuvarande emballage till prefabricerade väggar och bjälklag. Dagens emballage för prefabväggar och bjälklag följer inte med i utvecklingen. I arbetet undersöks möjligheterna att gå från plastemballage till pappemballage genom materialstudier och med den hållbara utvecklingen i åtanke.</p>
9

Orsaker och förebyggande åtgärder mot vattenskador i bostadskök / Causes and prevention of water damage in residential kitchens

Hellstadius, Adam, Hero, Alexander January 2014 (has links)
Med dagens teknikutveckling blir det allt vanligare med nya fräscha maskiner och bekvämligheter. I köket väljer fler och fler att ha diskmaskin, frys med ismaskin, kaffemaskin med mera. Detta leder till ökat antal vattenanslutningar i ett kök. Risken för att en vattenskada ska uppstå är i stort sett lika stor som i ett badrum, ändå klassas inte kök som ett våtrum, vilket ger en stor risk för att omfattande vattenskador ska uppstå. Länsförsäkringar Södermanland har tyckt sig märka att de genomsnittliga skadekostnaderna hos företaget har ökat de senaste åren. De är därför intresserade av att få en liten bild av vad detta kan bero på och vart den största ökningen sker. Rapporten kommer behandla vattenskador i bostadsvillors kök. Därför har följande frågor ställts: ”Vilka är de vanligaste orsakerna till fuktskador i kök?” och ”Vilka åtgärder kan man utföra för att förebygga de vanligaste fuktskadorna i befintliga kök?”. För att kunna besvara dessa frågor har en litteraturstudie genomförts för att se hur dagens branschregler ser ut och hur de sett ut under de undersökta åren, vilka är 2013, 2008 och 2005. Även enkla skadeförebyggande åtgärder som kan utföras i befintliga kök har undersökts. Därefter sammanställdes statistik från Länsförsäkringar Södermanlands skadesystem och jämfördes med nationell statistik ifrån Vattenskadecentrum. Denna statistik har analyserats med hjälp av teorin och den största ökningen som kunde ses var hos diskmaskinen. Detta har stor grund i att allt fler hushåll väljer att installera diskmaskin, vilket är förståeligt. Det är bekvämt och enkelt, speciellt om familjen är stor. En annan del som ökat är rören. De blir gamla och slitna och börjar då läcka. Eftersom rör ofta är svårtillgängliga är det bristande underhåll på dessa, och det är svårt att upptäcka om de läcker. Koppling/fog bidrar med en ganska stor andel skador, men denna post verkar vara på nedåtgående, vilket tyder på att det idag finns bättre kopplingar och folk är mer noggranna, då dessa ofta är ganska synliga. Hur ska då dessa skador förebyggas? Enkla åtgärder är att använda vattentäta skydd under kyl, frys och diskmaskin samt vattentätt ytskikt i diskbänksskåpet, för att leda fram läckande vatten så det blir synligt och kan åtgärdas. Vidare finns olika vattenlarm, vattenfelsbrytare, tryckslagsdämpare med mera som hjälper hushållet att vara vattensäkert.
10

Olika husgrunder med beaktning på fuktskador

Oskarsson, Sebastian January 2022 (has links)
No description available.

Page generated in 0.0423 seconds