1

Efeito do plasma de baixa temperatura e pressão no biofilme oral formado sobre esmalte em um modelo in situ / Effect of tissue-tolerable plasma on oral biofilms formed in situ

Alves, Karla Shangela da Silva 30 May 2016 (has links)
ALVES, K. S. S. Efeito do plasma de baixa temperatura e pressão no biofilme oral formado sobre esmalte em um modelo in situ. 2016. 58 f. Tese (Doutorado em Odontologia) - Faculdade de Farmácia, Odontologia e Enfermagem, Fortaleza, 2016. / Submitted by Erika Fernandes (erikaleitefernandes@gmail.com) on 2016-10-13T11:56:46Z No. of bitstreams: 1 2016_tese_kssalves.pdf: 1772314 bytes, checksum: 268cf8202a9a7e5f2e7c43d7ceff3d5e (MD5) / Approved for entry into archive by Erika Fernandes (erikaleitefernandes@gmail.com) on 2016-10-13T11:56:59Z (GMT) No. of bitstreams: 1 2016_tese_kssalves.pdf: 1772314 bytes, checksum: 268cf8202a9a7e5f2e7c43d7ceff3d5e (MD5) / Made available in DSpace on 2016-10-13T11:56:59Z (GMT). No. of bitstreams: 1 2016_tese_kssalves.pdf: 1772314 bytes, checksum: 268cf8202a9a7e5f2e7c43d7ceff3d5e (MD5) Previous issue date: 2016-05-30 / The Low temperature plasma is a promising technology that has being studied in dentistry for its various properties, among them, for their ability to destroy bacteria present in mature biofilm and also destroying the polymeric matrix of oral biofilms. The aim of this study was to evaluate the antimicrobial effect of argon plasma on oral biofilms formed in situ and also verify if this treatment damages the structure of the treated enamel. For that, twenty-two volunteers used palatine intraoral devices containing 6 to bovine enamel slabs that were dripped sucrose 10 times a day with 10% sucrose. The intraoral period was 7 days. At the 7th day, enamel slabs were treated for 5 minutes with plasma, argon flow, 0.12% chlorhexidine, or 0.89% NaCl solution. Thus, biofilms samples were collected, weighed, serial diluted and plated in culture medium for the growth of total microorganisms, total streptococci, mutans streptococci and lactobacilli. In order to analyze whether the treatments damaged the enamel structure, the slabs were analyzed by scanning electron microscopy (SEM) and Raman spectroscopy. Low temperature plasma treatment showed a significant reduction in the viability of the total microorganisms (p <0.001), total streptococcus (p = 0.037) and mutans streptococci (p = 0.004). Argon flow also significantly reduced the mutans streptococci counts. The plasma treatment did not influence on the viability of the lactobacilli under the conditions tested (p = 0.497). SEM revealed smooth and homogeneous regions on the enamel surface, unobserved topographical differences between the glazes in biofilms subjected to different treatments. In Raman spectroscopy, we identified four major bands present in the inorganic phase: 324 (V1), 582 (V2), 960 (V3) e 1045 (V4) cm-1 and other 4 identified in the organic layer 1448 (V5), 1465 (V6), 1653 (V7) 2943(V8) cm-1. No statistical differences in the Raman spectra were observed for enamel of different treatments. In conclusion, the plasma was effective in reducing viable bacteria present in mature oral biofilms produced in situ and not alter in the enamel surface treated biofilms. / O plasma de baixa temperatura é uma tecnologia promissora que vem sendo estudada na odontologia por suas várias propriedades, dentre elas, por sua capacidade de destruir bactérias presentes em biofilme maduro destruindo a matriz do biofilme oral. O objetivo deste estudo foi avaliar o potencial antimicrobiano do plasma de argônio de baixa temperatura em biofilmes orais formados in situ e verificar se o tratamento proposto danifica a estrutura do esmalte tratado. Para tanto, vinte e dois voluntários utilizaram dispositivos intraorais palatinos contendo 6 blocos de esmalte bovino que foram gotejados sacarose 10 vezes ao dia uma solução de sacarose a 10%, durante 7 dias. Ao final do período intraoral, os biofilmes formados sobre os blocos de esmalte receberam tratamento durante 5 minutos com plasma de argônio, gás argônio, clorexidina a 0,12%, ou solução salina de NaCl a 0,89%. As amostras dos biofilmes foram coletadas, pesadas, diluídas de forma seriada e plaqueadas em meio de cultivo para o crescimento de microrganismos totais, estreptococos totais, estreptococos do grupo mutans e lactobacilos. A fim de analisar se os tratamentos danificaram a estrutura do esmalte, os blocos foram analisados por microscopia eletrônica de varredura (MEV) e por espectroscopia Raman. O tratamento do plasma mostrou uma redução significativa na viabilidade dos microrganismos totais (p <0,001), estreptococos totais (p = 0,037) e estreptococos do grupo mutans (p = 0,004). O gás de argônio também reduziu significativamente as contagens de estreptococos do grupo mutans. O tratamento com plasma não demonstrou influência sobre a viabilidade dos lactobacilos nas condições testadas (p = 0,497). A MEV revelou regiões lisas e homogêneas na superfície do esmalte, não sendo observadas diferenças topográficas entre os esmaltes sob biofilmes submetidos aos diferentes tratamentos. No Raman, foram identificadas quatro bandas principais presentes na fase inorgânica: 324 (V1), 582 (V2), 960 (V3) e 1045 (V4)cm-1 e outras 4 identificadas na fase orgânica 1448 (V5), 1465 (V6), 1653 (V7) 2943(V8) cm-1, não ocorrendo diferenças estatísticas entre os espectros do Raman nos blocos de esmaltes dos diferentes tratamentos. Em conclusão, o plasma foi eficaz na redução de bactérias viáveis presentes em biofilmes orais maduros produzidas in situ e não alterou a superfície do esmalte sob biofilme tratado.
2

Desenvolvimento e caracterização físico-química de um novo filme de PECVD na melhora da resistência de união entre a Y-TZP e a cerâmica de cobertura / Development and physical-chemical characterization of a novel PECVD film to improve the bond strength between Y-TZP and veneering ceramic

Bitencourt, Sandro Basso [UNESP] 24 February 2017 (has links)
Submitted by Sandro Basso Bitencourt null (sandrodonto@gmail.com) on 2017-03-23T13:07:44Z No. of bitstreams: 1 Dissertação final - revisado pela biblioteca.pdf: 1890741 bytes, checksum: 67162843354d597f4f93a297398b42fc (MD5) / Approved for entry into archive by Luiz Galeffi (luizgaleffi@gmail.com) on 2017-03-23T16:14:48Z (GMT) No. of bitstreams: 1 bitencourt_sb_me_araca.pdf: 1890741 bytes, checksum: 67162843354d597f4f93a297398b42fc (MD5) / Made available in DSpace on 2017-03-23T16:14:48Z (GMT). No. of bitstreams: 1 bitencourt_sb_me_araca.pdf: 1890741 bytes, checksum: 67162843354d597f4f93a297398b42fc (MD5) Previous issue date: 2017-02-24 / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / A obtenção de uma união duradoura da interface zircônia/cerâmica de cobertura é uma preocupação para sucesso clínico de restaurações livres de metal e ainda não existem evidências que indiquem uma técnica de tratamento dessa zircônia com melhor previsibilidade e durabilidade. Assim, o objetivo desse estudo foi desenvolver e caracterizar fisico-quimicamente um novo filme por vapor químico melhorado por plasma (plasma enhanced chemical vapor deposition – PECVD) na superfície da zircônia tetragonal policristalina estabilizada por óxido de ítrio (Y-TZP) para melhorar sua resistência de união com cerâmica de cobertura. Para isso, um total de 192 amostras de Y-TZP (13×5,4×5 mm) foram divididas em 6 grupos, de acordo com o tratamento de superfície: controle – sem tratamento (C), jateamento com partículas de óxido de alumínio de 27 µm (Al27), jateamento com partículas de óxido de alumínio de 110 µm (Al110), jateamento com partículas de óxido de alumínio de 250 µm (Al250), aplicação de liner para zircônia (L) e o filme por PECVD (P). A superfície da Y-TZP foi caracterizada por meio da microscopia eletrônica de varredura (MEV), espectroscopia de energia dispersiva (EED), microscopia de força atômica (MFA), perfilometria e energia livre de superfície. A resistência de união entre a Y-TZP e uma cerâmica de cobertura foi testada antes e após fadiga térmica (20.000 ciclos de 5 e 55 °C). Os dados foram submetidos à análise de variância e teste Tukey HSD (α=0,05). Como resultados, foi encontrado que o grupo P não alterou a rugosidade de superfície da Y-TZP (P>0,05 vs controle), enquanto os grupos Al110, Al250 e L apresentaram os maiores valores (P<0,05). Todos os tratamentos melhoraram a energia livre de superfície da Y-TZP, exceto o Al27. O grupo P mostrou os maiores valores de resistência ao cisalhamento (P<0,05), sendo semelhante apenas ao grupo Al27 (P=0,107). Os demais grupos foram similares ao controle (P>0,05). A fadiga térmica não afetou a interface Y-TZP/cerâmica de cobertura. Filmes produzidos pela deposição por plasma não promovem alterações estruturais na Y-TZP e são promissores para melhorar a interface de união Y-TZP/cerâmica de cobertura. / The obtainment of a durable zirconia/veneer ceramic interface bond is a preoccupation for clinical success of metal-free restorations and did not exist evidence indicates that the technique with the best predictability and durability. Thus, the aim of this study was to develop and to physico-chemically characterize a novel film formed after plasma enhanced chemical vapor deposition (PECVD) on the yttria stabilized tetragonal zirconia (Y-TZP) surface aiming to improve its bond strength to the veneer ceramic. For this, a total of 192 YTZP samples (13×5.4×5 mm) were divided in 6 groups, according the surface treatment: control – no treatment (C), airborne-particle with 27 µm aluminum oxide (Al27), airborneparticle with 110 µm aluminum oxide (Al110), airborne-particle with 250 µm aluminum oxide (Al250), zirconia liner (L) and the film by PECVD (P). The Y-TZP surface was characterized through scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), atomic force microscopy (AFM), surface roughness and surface free energy. The bond strength between Y-TZP and veneer ceramic was tested before and after thermal fatigue (20,000 cycles of 5 and 55ºC). The data were submitted to analysis of variance and Tukey HSD test (α=0.05). The results were that the roughness of Y-TZP surface was not modified in the P group (P>0.05 vs control), while the Al110, Al250 and L groups showed higher roughness values (P<0.05). All the treatments improved the surface free energy of Y-TZP, except for the Al27 group. The P group showed higher shear bond strength (P<0.05), similar only to the Al27 group (P=0.107). The other groups were similar to control (P>0.05). The thermal fatigue did not affect the Y-TZP/veneer ceramic interface. Films produced by the PECVD deposition did not promote structural changes on the Y-TZP and are promising to improve the bond interface Y-TZP/veneer ceramic. / FAPESP: 2015/10826-9 / FAPESP: 2015/11412-3
3

Efeitos do tratamento com plasma não térmico em superfícies de titânio e materiais cerâmicos / Effects of treatment with nonthermal plasma in titanium surfaces and ceramic materials

Garcia, Bruna Albuquerque 17 February 2016 (has links)
GARCIA, B. A. Efeitos do tratamento com plasma não térmico em superfícies de titânio e materiais cerâmicos. 2016. 80 f. Dissertação (Mestrado em Odontologia) - Faculdade de Farmácia, Odontologia e Enfermagem, Universidade Federal do Ceará, Fortaleza, 2016. / Submitted by Erika Fernandes (erikaleitefernandes@gmail.com) on 2016-04-14T12:44:02Z No. of bitstreams: 1 2016_dis_bagarcia.pdf: 15249907 bytes, checksum: 657c855023b2ef0cf06e6516372f48bb (MD5) / Approved for entry into archive by Erika Fernandes (erikaleitefernandes@gmail.com) on 2016-04-14T12:44:12Z (GMT) No. of bitstreams: 1 2016_dis_bagarcia.pdf: 15249907 bytes, checksum: 657c855023b2ef0cf06e6516372f48bb (MD5) / Made available in DSpace on 2016-04-14T12:44:12Z (GMT). No. of bitstreams: 1 2016_dis_bagarcia.pdf: 15249907 bytes, checksum: 657c855023b2ef0cf06e6516372f48bb (MD5) Previous issue date: 2016-02-17 / Adhesive properties of dental materials such as wetting and surface roughness are important for studies of cementing effects of prosthetic devices, repairs and restorations, combining different materials and even cell adhesion in surgical biomaterials. Modifications in the surfaces of these materials can contribute to improve these properties. This study examined the effects of treatment with argon plasma on surfaces of pure titanium, glass-ceramics reinforced by lithium disilicate and feldspar ceramic. Titanium specimens were divided into three groups (n=5): no treatment (NT); treatment with argon gas, 6 minutes; and treatment with argon plasma, 6 minutes, 10W/1 bar. Contact angle after treatment (IT) - after one hour (HT) and after one week (WT); surface roughness (Sa); and evaluation in a scanning electron microscope (SEM) were analyzed. Ceramic specimens were divided into two groups (n=5): NT and argon plasma 6 minutes, 10W / 1 bar. Contact angle after treatment (IT) – after one hour (HT) and after one week (WT); and surface roughness (Sa) and SEM evaluation and microtensile (MPa) were analyzed. The data were submitted to the Shapiro-Wilk test, analysis of variance (one-way), Tukey and t-Student test (α=0.05). In titanium there was a significant decrease in the contact angle (p<0.0001) in plasma group IT (8.4±1.8), HT (15.7±3.4) and WT (14.8±4.5) compared to the NT group (30.7±1.6). By comparing the gas group IT (24.1±6.1), HT (26.5±6.3) and WT (26.2±5.7) to the NT group (30.7±1.6) there was no significant difference (p=0.0793). There was a significant increase in surface roughness (p=0.0144) in the group treated with plasma (1.1±0.04) compared to NT groups (0.09±0.08) and gas group (1.0±0.05). In SEM, there was more irregular surface in the specimens treated with plasma. Lithium disilicate showed a significant decrease (p=0.0003) contact angle plasma group IT (5.0±0.2) and HT (5.5±1.0) when compared with the group NT (9.6±2.6); showed a significant increase in surface roughness (p=0.02) in the plasma group (1.1±0.4) when compared to the NT group (0.6±0.2) and a significant increase in bond strength (MPa) of a resin cement (p=0.0005) in plasma group (27.6±3.7) compared to the NT group (11.2±2.1). In feldspathic ceramics, when compared to the contact angle of the NT group (30.0±6.5), plasma IT (8.3±2.7), HT (12.9±3.3) and ST (16,2±2.4), we observed a significant (p<0.0001) plasma group; the surface roughness has increased significantly (p=0.03) in the plasma group (1.7±0.6) when compared to the NT group (1.0±0.2). The SEM images plasma group when compared to the NT group exhibited a much more irregular topography both for lithium disilicate and for feldspar. The treatment with argon plasma enhanced wetting and increased roughness of the three surface examined materials: titanium and ceramic lithium disilicate and feldspar. This treatment also increased the bond strength in adhesive cementation on ceramic lithium disilicate. / Propriedades adesivas dos materiais odontológicos, como molhamento e rugosidade de superfície são importantes para estudos de efeitos de cimentações de peças protéticas, restaurações e reparos, unindo diferentes materiais e, até mesmo, adesão de células em biomateriais cirúrgicos. Modificações nas superfícies desses materiais podem contribuir para melhoria dessas propriedades. Este estudo analisou os efeitos do tratamento com plasma não térmico em superfícies de titânio puro, cerâmicas vítreas reforçadas por dissilicato de lítio e cerâmica feldspática. Espécimes de titânio foram distribuídos em três grupos (n=5): sem tratamento (ST); tratamento com gás argônio, 6 minutos; e tratamento com plasma de argônio, 6 minutos, 10W/1 bar. Foram analisados: ângulo de contato logo após o tratamento (TI), após uma hora (TH) e após uma semana (TS); rugosidade de superfície (Sa); e topografia de superfície (MEV). Espécimes das cerâmicas foram distribuídos em dois grupos (n=5): ST e plasma de argônio 6 minutos, 10W/1bar. Foram analisados: ângulo de contato logo após o tratamento (TI), após uma hora (TH) e após uma semana (TS); rugosidade de superfície (Sa); topografia de superfície (MEV) e resistência de união (MPa). Os dados foram submetidos aos testes Shapiro-Wilk, análise de variância (um critério), Tukey e t de Student (α=0,05). No titânio houve diminuição significativa do ângulo de contato (p<0,0001) no grupo plasma TI (8,4±1,8), TH (15,7±3,4) e TS (14,8±4,5), comparando-se ao grupo ST (30,7±1,6). Ao comparar o grupo gás TI (24,1±6,1), TH (26,5±6,3) e TS (26,2±5,7) ao grupo ST (30,7±1,6), não houve diferença significativa (p=0,07). Houve aumento significativo da rugosidade de superfície (p=0,01) no grupo tratado com plasma (1,1±0,04) quando comparados aos grupos ST (0,09±0,08) e grupo gás (1,0±0,05). No MEV, observou-se superfície mais irregular nos espécimes tratados com plasma. O dissilicato de lítio apresentou uma redução significativa (p=0,0003) do ângulo de contato no grupo plasma TI (5,0±0,2) e TH (5,5±1,0), quando comparado ao grupo ST (9,6±2,6); apresentou um aumento significativo na rugosidade superficial (p=0,02) no grupo plasma (1,1±0,4) quando comparado ao grupo ST (0,6±0,2) e um aumento significativo na resistência de união (MPa) (p=0,0005) no grupo plasma (27,6±3,7) quando comparado ao grupo ST (11,2±2,1). Na cerâmica feldspática, quando comparado o ângulo de contato dos grupos ST (30,0±6,5), plasma TI (8,3±2,7), TH (12,9±3,3) e TS (16,2±2,4), observou-se uma redução significativa (p<0,0001) do grupo plasma; na rugosidade de superfície houve um aumento significativo (p=0,03) no grupo plasma (1,7±0,6) quando comparado ao grupo ST (1,0±0,2). As imagens do MEV do grupo plasma, quando comparadas com o grupo ST, apresentaram uma topografia mais irregular tanto para o dissilicato de lítio, quanto para a feldspática. O tratamento com plasma não térmico melhorou o molhamento e aumentou a rugosidade de superfície dos três materiais analisados: titânio e cerâmicas de dissilicato de lítio e feldspática. Esse tratamento, também aumentou a resistência de união na cimentação adesiva em cerâmicas de dissilicato de lítio.
4

Efeitos do plasma de baixa temperatura sobre os substratos esmalte e dentina / Effecs of low temperature plasma on enamel and dentin substrates

Alves, Roberto Haniery Ponte 22 July 2015 (has links)
ALVES, R. H. P. Efeitos do plasma de baixa temperatura sobre os substratos esmalte e dentina. 2015. 44 f. Dissertação (Mestrado em Odontologia) - Faculdade de Farmácia, Odontologia e Enfermagem, Universidade Federal do Ceará, Fortaleza, 2015. / Submitted by Erika Fernandes (erikaleitefernandes@gmail.com) on 2016-05-24T12:42:59Z No. of bitstreams: 1 2015_dis_rhpalves.pdf: 3211354 bytes, checksum: a18ac67c873e9bb8b5db147d33558b04 (MD5) / Approved for entry into archive by Erika Fernandes (erikaleitefernandes@gmail.com) on 2016-05-24T12:43:14Z (GMT) No. of bitstreams: 1 2015_dis_rhpalves.pdf: 3211354 bytes, checksum: a18ac67c873e9bb8b5db147d33558b04 (MD5) / Made available in DSpace on 2016-05-24T12:43:14Z (GMT). No. of bitstreams: 1 2015_dis_rhpalves.pdf: 3211354 bytes, checksum: a18ac67c873e9bb8b5db147d33558b04 (MD5) Previous issue date: 2015-07-22 / Low-temperature plasma (LTP) is a promising technology with the potential benefit of destroying the matrix of the oral biofilm and also produce antimicrobial effect on the bacterial cell. However, the effect of LTP on dental structures is not clear. The objective of this study was to evaluate the effect of LTP on enamel and dentin substrates. Therefore, we analyzed Knoop microhardness to calculate the percentage of surface hardness (SH), changes in contact angles (CA), the surface topography by Scanning Electron Microscopy (SEM) and also the chemical composition by Raman spectrometry (RS). Initially, 4x4x2 mm enamel and dentin blocks were prepared from bovine incisors. All blocks were polished and divided into three groups (n = 6); argon plasma, argon flow rate and control. The SH was assessed before and after each treatment, performing five penetrations in each specimen (50g / 25g and 5s enamel / dentin 5s). Contact angles changes were performed by dispersing water drop on the treated surfaces and observing the contact angle obtained after 1 min and 1 hour. For that, high-resolution digital photos and the Image J program was used. Physical changes in the structure of enamel and dentin submitted to LTP were observed from the SEM. Additionally, the relative proportion of the organic and mineral content of the enamel and dentin after treatment were analyzed by RS. Data were evaluated by analysis of variance (ANOVA) - 2-way (treatment and time) and Tukey test (α <0.05). For the SH the results showed no significant difference in the enamel (p=0.087), however, the SH of dentin decreased after treatment with argon plasma (p=0.005). The results indicated that water contact angle values in enamel decreased after 1min of the application of argon plasma (p<0.05). In the dentin the contact angle decreased after 1 and 60 min of the application of argon plasma (p<0.05). The RS results showed than argon plasma and argon gas presented lower organic matrix bands, similar results were observated for both enamel and dentin. The SEM showed that in addition to removing the external smear layer to the dentinal tubules, treatment with LTP promoted cracks in the enamel and the dentin surfaces. In conclusion, the use of argon plasma decreased the superficial hardness in dentin and, potentially increased the wetting in booth substract. Superficial morphological change and decreased of the organic matrix were observed in booth estructures after treatment with argon plasma and argon flow rate. / O plasma de baixa temperatura (PBT) tem tido seu uso investigado na destruição dos biofilmes orais, no entanto, seu efeito sobre os substratos dentários ainda não está completamente esclarecido. O objetivo deste trabalho foi avaliar o efeito do PBT na dureza superficial, no ângulo de contato, na morfologia das superfícies e composição química do esmalte e dentina bovinos. Para tanto, foram analisados a dureza de superfície Knoop (DS), as alterações nos ângulos de contato (AC), a morfologia de superfície por Microscopia Eletrônica de Varredura (MEV) e sua composição química através da Espectofotometria Raman (ER). Inicialmente, foram confeccionados blocos de esmalte e dentina com dimensões de 4x4x2 mm preparados a partir de dentes bovinos. Todos os blocos foram polidos e dividos em três grupos (n=6): Plasma de Argônio, Gás de Argônio e Controle. A DS foi avaliada antes e depois de cada tratamento, realizando-se cinco penetrações em cada espécime (50g/5s para esmalte e 25g/5s para dentina). A determinação do AC foi realizada dispersando uma gota de água sobre a superfície tratada e observando o ângulo de contato obtido em 1 min e 1 hora, utilizando fotografias digitais de alta resolução e o programa Image J. As alterações físicas na morfologia do esmalte e dentina submetidos ao PBT foram observadas a partir da MEV. Adicionalmente, a proporção relativa do conteúdo orgânico e mineral do esmalte e dentina após os tratamentos foram analisados por ER. Os dados foram avaliados por análise de variância (ANOVA) – 1 via para DS e 2 vias (tratamento e tempo) para AC, após Tukey teste (α < 0,05). Os resultados da DS demostraram não haver diferença significativa no esmalte (p = 0,087) após os tratamentos. No entanto, a MS da dentina diminuiu após o tratamento de plasma de argônio (p = 0,005). Os resultados indicaram que os valores de ângulo de contato da água diminuíram após 1 minuto da aplicação de plasma de argônio no esmalte (p < 0,05) e após 1 minuto e 60 minutos da aplicação de plasma de argônio na dentina (p < 0,05). Os resultados da ER demonstraram que os tratamentos com o plasma de argônio e gás de argônio apresentaram menores intensidades nas bandas da matriz orgânica para o esmalte e para a dentina. Em adição, a MEV demonstrou que, além de remover a smear layer externa aos túbulos dentinários, o tratamento com PBT promoveu rachaduras na superfície do esmalte e da dentina. Em conclusão, o PBT diminuiu a dureza superficial da dentina e melhorou potencialmente o molhamento da superfície do esmalte e dentina. Alterações morfológicas superficiais e diminuição da matrix orgânica foram observadas para ambas as estruturas dentais, depois dos tratamentos com plasma de argônio e gás de argônio.
5

Atividade antifúngica da associação entre plasma frio em pressão atmosférica e antifúngicos poliênicos convencionais sobre biofilmes de Candida albicans. /

Leite, Lady Daiane Pereira January 2020 (has links)
Orientador: Cristiane Yumi Koga-Ito / Resumo: A crescente incidência da resistência às drogas antifúngicas tornou-se um grande desafio para áreas médica e odontológica, fazendo com que a busca por métodos de tratamento alternativos ou em combinação com as já utilizadas sejam urgentemente necessárias. O objetivo deste projeto foi avaliar os efeitos da associação entre o plasma frio em pressão atmosférica e antifúngicos poliênicos convencionais utilizados no tratamento tópico da candidose bucal. Para tanto, foram realizados: a) Determinação das concentrações inibitórias dos antifúngicos poliênicos nistatina e anfotericina B e do plasma frio em pressão atmosférica sobre biofilmes de C. albicans; b) Avaliação do efeito dos tratamentos isolados e associados em condições/concentrações sub-inibitórias para fins de comparação e c) Avaliação dos diferentes protocolos de aplicação dos tratamentos, visando a obtenção da condição experimental mais eficaz para o controle do biofilme fúngico. Os dados de unidades formadoras de colônia foram comparados estatisticamente entre os grupos por One-way ANOVA e post hoc Tukey, com nível de significância de 5%. A partir dos resultados obtidos, pode-se concluir que o jato de plasma apresentou efeito antifúngico similar quando aplicado isoladamente ou em associação com nistatina e anfotericina B. Ainda, foi possível concluir que o jato de plasma frio apresenta efeito antifúngico mais eficaz do que os tratamentos dos biofilmes utilizando nistatina e anfotericina B no tempo de 5 minutos. / Abstract: The increasing incidence of antifungal resistance represents a great challenge in the medical areas and Dentistry. For this reason, the search for alternative methods or combination with the conventional ones is urgently necessary. The aim of this project is to evaluate, the effects of association between atmospheric pressure cold plasma and conventional polyene antifungals used for the treatment of oral candidiasis will be studied. With this purpose, the following methodologies were be used: a) To determine the inhibitory concentrations of the polyene antifungals nystatin and amphotericin B and cold plasma on C. albicans biofilms, b) To evaluate the combination of treatments in subinhibitory conditions, including isolated treatments for comparison purposes and c) To evaluate different protocols of treatment application, aiming to obtain the most effective protocol against fungal biofilm. Data was compared by One-way ANOVA and post hoc Tukey, with a significance level of 5%. Considering the results, it could be concluded that cold plasma showed similar effects when applied alone or in association to nystatin and amphotericin B. Cold plasma showed more effective antifungal effect on biofilms when compared to nystatin and amphotericin B, after 5 min exposure. / Mestre

Page generated in 0.0428 seconds