Análise dos tempos máximos de chaveamento dos modos de operação de um grupo gerador diesel após ilhamento / Analysis of the maximum switching times of the operating modes for a diesel generator set after islanding

Elian João Agnoletto 21 July 2015 (has links)
A produção de energia elétrica por fontes de geração distribuída (GD) vem se tornando cada vez mais presente no sistema elétrico de potência. De modo geral, os sistemas de GD conectados à rede de distribuição operam controlando potências ativa e reativa, enquanto que no modo isolado, a frequência e a tensão. Sendo assim, após a ocorrência de um ilhamento deve haver alteração no modo de operação da GD para garantir a estabilidade da frequência e da tensão no subsistema ilhado. Ainda, se o modo de operação não for alterado após o ilhamento, os dispositivos de proteção podem atuar desligando a GD. Portanto, o tempo decorrido até a alteração do modo de operação desempenha um papel importante na indicação se a GD permanecerá ou não em funcionamento após a ocorrência do ilhamento. Neste trabalho, são determinados os tempos máximos para chaveamento dos modos de operação de um grupo motor gerador diesel (GMG) operando como GD, utilizando controladores clássicos (CCs) e controladores fuzzy (CFs). Foram analisadas as influências do desbalanço entre as potências geradas e consumidas, do tipo de carga conectada ao subsistema ilhado e do comprimento do alimentador nos tempos máximos. Para evidenciar possíveis vantagens da estratégia de controle não linear, é utilizada uma metodologia na qual o ajuste dos ganhos dos CFs é realizado a partir dos ajustes de referência dos CCs. Devido ao ganho variável que a estratégia não linear adiciona às ações de controle, a utilização de CFs nas malhas do GMG permitiu maiores tempos de chaveamento para determinadas faixas de operação, quando comparado com a utilização de CCs. / Distributed generation (DG) is becoming more present in the electrical power system. In general, when a DG is connected to the grid, the DG works with the active and reactive power control loops. Therefore, after an islanding occurrence, the DG must change the operation control mode from power control to voltage and frequency control to maintain the system stability. If the operation mode is not changed after islanding, the protective devices are sensitized and the DG is disconnected. Therefore, the time elapsed until the operation mode changes has an important role in the indication if the DG remains in operation or not after islanding. In this work, the maximum times for switching the operating control mode of a diesel generator set, working as a DG, are analysed using a classical control strategy (CC) and a fuzzy control strategy (FC). The influence of the power imbalance, load types and the feeder distance on the maximum available time to switch the operation control mode is investigated. To highlight the advantages of a nonlinear control strategy, is used a methodology in which the tuning of the FCs gains is performed from the CCs which are used as reference. Due to the variable gain added by the nonlinear strategy, the FC allowed higher switching times than the CC.
22

Estratégia de controle fuzzy para um grupo motor gerador a diesel operando isolado ou conectado à rede de distribuição / A fuzzy control strategy for a diesel generating set under stand-alone and grid-connected operations

Reis, Giann Braune 01 April 2014 (has links)
Esta tese propõe uma estratégia de controle fuzzy para um grupo motor gerador a diesel como uma fonte de geração distribuída, cobrindo a parte mecânica do sistema que é composta por controle de velocidade e de potência ativa, a parte elétrica do sistema composta por controle de tensão e potência reativa, e também o controle de sincronismo com a rede de distribuição. A estratégia de controle foi baseada em lógica fuzzy que usou uma superfície de controle fixa para os controladores fuzzy. Foram investigados os distúrbios causados pelo efeito de conexão com a rede e da conexão de um motor de indução, um retificador não controlado e uma carga RLC. Resultados de simulação para fluxo de potência no modo conectado foram obtidos usando um alimentador padrão IEEE -1547. Os resultados de simulação obtidos para os modos isolado e conectado usando o controlador fuzzy foram superiores comparados aos resultados obtidos com um controlador comercial. Uma bancada experimental também foi usada para analisar a resposta do sistema no modo isolado com o controlador fuzzy proposto e com o controlador comercial para fins de comparação. Nesse contexto, espera-se com este trabalho contribuir para o desenvolvimento de pesquisas na área de controle e processamento de energia, uma vez que, soluções para a produção de energia utilizando a geração distribuída têm importância estratégica e têm sido foco de investimento e discussões por parte de governos, empresas e universidades. / This thesis proposes a control strategy for a diesel generating set as a distributed generation source covering the mechanical part of the system which includes speed and active power control, the electrical part of the system which includes voltage and reactive power control, and also the synchronism control with the grid. The control strategy was based on a fuzzy logic which used a fixed controller surface for the fuzzy controllers. The effect of the disturbances caused by the grid connection and the disturbances caused by the activation of a induction motor, non controled rectifier and a RLC load types were investigated. Power flow simulation results for the grid-connected mode was obtained with a IEEE -1547 standard feeder. The simulations results for both stand-alone and gridconnected operations using fuzzy controllers were superior when compared to commercial methods. An experimental setup was also used to analyze the system responses under isolated mode with the proposed fuzzy controller and with the commercial controllers for comparison proposes. In this context, it is expected that this work contributes to the development of control and energy processing research area, since solutions for energy production using distributed generation have strategic importance and have been the focus of investment and discussions from governments, companies and universities.
23

Controle de tensão terminal e potência reativa de um grupo motor gerador diesel conectado à rede de distribuição / Terminal voltage control and reactive power of a powerplant diesel generator connected to the distribution network

Neves, Rodolpho Vilela Alves 19 March 2013 (has links)
Este trabalho apresenta uma estratégia de controle coordenado para potência reativa e tensão terminal de um grupo moto gerador (GMG) para uso em um sistema de geração distribuída (GD). A partir da construção de uma superfície fuzzy, baseada no comportamento do erro e da derivada do erro de uma malha de controle, foi realizada a sintonia de controladores fuzzy PD+I para potências ativa e reativa e tensão terminal. O controlador coordenado fuzzy PD+I ajusta automaticamente a tensão nos terminais da máquina e a potência reativa fornecidas à rede de distribuição. A estratégia coordenada é dada através de um parâmetro que regula a malha de potência reativa a partir do erro de tensão terminal, priorizando o ajuste da tensão e ponderando a malha de controle de potência reativa. Para avaliar o desempenho do sistema de controle, a GD é conectada a uma rede de distribuição e submetida a eventos como entrada e saída de cargas locais. O conjunto de cargas locais é composto por um motor de indução, uma carga RLC e um retificador trifásico não controlado. Sete cenários foram simulados para avaliar a estratégia de controle em diferentes regimes de operação do GMG. Resultados para tensão terminal, fator de potência e fluxo de potências entre o sistema, as cargas e a rede, ilustram a eficiência da estratégia de controle apresentada. A estratégia de controle coordenado para potência reativa e tensão terminal se mostrou capaz de melhorar os índices de fator de potência controlando o fluxo de potência do barramento em que a GD estava conectada, sem prejudicar a tensão terminal do gerador, mantendo a GD em limites seguros de operação. / This work presents a coordinated control strategy to terminal voltage and reactive power for a diesel generation set used as a distributed gerenation system (DG). From desired control actions, a fuzzy surface was designed for fuzzy PD+I controllers. Fuzzy PD+I controllers automatically adjust the terminal voltage and the reactive power delivered to the grid. The coordinated control strategy weighs the control action for the reactive power through a variable parameter, prioritizing the terminal voltage adjustment. To illustrate the system control performance, the DG is connected to a grid dynamic model and the system is subjected to connection and disconnection of loads at the local bus. The local loads set was composed of an induction machine, a RLC load and an uncontrolled three-phase rectifier. Seven scenarios were simulated to evaluate the control strategy in different DG regime of operation. Results for terminal voltage, power factor and reactive power among the DG, the local loads and the grid, illustrates the control strategy efficiency improved the power factor by regulating the reactive power injected at the bus, maintaining the DG terminal voltage in safe operation limits.
24

Uma modelagem da máquina síncrona considerando o efeito da curvatura da sapata polar

Alves, Aylton José 15 April 2011 (has links)
This work develops a new mathematical model to the salient pole synchronous machines (SPSM), based on the abc reference system. The model considers the distribution and coil pitch factors of windings and develops a new function for the variable air gap, generated by the curvature of the polar mass. As a result, the development of the modeling takes into account the spatial harmonic components of: magneto motive force MMF(θ)h, electromagnetic ux density B(θ)h and variation function of the air gap g(θ)h. It is also proposed a new and simplied methodology using the locked rotor tests, volt-ampere method, to obtain the constants of the synchronous machine design, which allow the calculation of the modeling parameters and the terminals magnitudes determination. It presents also contributions to traditional methods of obtaining experimental inductances, using the locked rotor test. Yet it develops procedures and makes the simulation of the main temporal magnitudes at the generator terminals connected to the utility grid, electrical torque, speed, voltage and current. The model is validated through the theoretical and experimental confrontation of inductances, and also of the voltages and currents at the generator terminals connected to the utility grid. / Este trabalho desenvolve uma nova modelagem matemática para as máquinas síncronas de polos salientes (MSPS), baseada no sistema abc de referência. A modelagem considera os fatores de distribuição e de passo de bobina dos enrolamentos e desenvolve uma nova função para o entreferro variável, gerado pela curvatura da sapata polar. Como conseqüência o desenvolvimento da modelagem leva em consideração os componentes harmônicos espaciais de: força magneto motriz FMM(θ)h, densidade de uxo eletromagnético B(θ)h e da função de variação do entreferro g(θ)h. É também proposto uma nova e simplificada metodologia a partir dos testes de rotor bloqueado, método volt-ampere, para a obtenção das constantes de projeto da máquina síncrona que possibilitam os cálculos dos parâmetros da modelagem, bem como a determinação das grandezas terminais. Também apresenta contribuições aos métodos tradicionais de obtenção de indutâncias experimentais, a partir dos testes de rotor bloqueado. Ainda desenvolve os procedimentos e faz a simulação das principais grandezas temporais nos terminais do gerador conectado à rede da concessionária: torque elétrico, velocidade, corrente e tensão. A modelagem é convalidada através das confrontações teórico-experimental das indutâncias, e também dos resultados de correntes e tensões nos terminais do gerador conetado à rede da concessionária. / Doutor em Ciências
25

Uma proposta de regulador automático de tensão microcontrolado para geradores síncronos isolados

Alves, Guilherme Henrique 16 September 2016 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Os sistemas de controle de excitação em máquinas síncronas devem detectar com bastante rapidez as mudanças causadas pela entrada de carga no gerador isolado e atuar no sistema de excitação de forma rápida e eficiente, para manter a tensão terminal em níveis desejados. Ao contrário de outros trabalhos realizados nesta área com circuitos eletrônicos analógicos, em muitos casos, este controlador pode ser construído utilizando tecnologia microcontrolada por possuir alto nível de eficiência no controle, circuito com flexibilidade para implementação de diferentes estratégias de controle e baixo custo para produção. A abordagem deste trabalho consiste em uma proposta para aplicação de um controle de excitação automático utilizando uma malha PID, com opções de controle manual, monitoramento de tensão terminal e temperatura de estator da máquina, utilizando um microcontrolador PIC16F877A da empresa Microchip Technology. Os resultados obtidos a partir de ensaios práticos em laboratório com partidas diretas de motores de indução (1 e 2 cv) com um gerador de 2 kVA mostra que a atuação do controlador recuperou a tensão terminal em pouco tempo, para o setpoint adotado. E por fim, os resultados obtidos foram comparados com os tempos de resposta de outro conhecido regulador automático de tensão encontrado no mercado, para comprovar o bom desempenho de controle deste projeto. / The excitation control systems in synchronous machines must very quickly detect changes caused by load increase on the isolated generator and act on the excitation system in a rapid and efficient way in order to maintain terminal voltage at optimal desired levels. Unlike other works related with this area which used analog-based electronic circuits, this controller can in many case be built utilizing microcontrolled technology which is more efficient and flexible to implement different control strategies, as well as having a low cost of production. The approach of this research consists in a proposal to apply an automatic excitation controller, utilizing a PID control loop, including manual adjustments and monitorings of terminal voltage and stator temperature of the machine. It employs a PIC16F877A microcontroller from the Microchip Technology Company. The results obtained through practical tests in laboratory with a direct online start of induction motors (1 and 2 HP) on a 2 kVA generator show that the controller acts to recover the terminal voltage to the adopted setpoint in a reduced time. Finally, the results were also compared to the time of response provided from another well-known automatic voltage regulator found in the market, in order to prove the good control performance of this project. / Dissertação (Mestrado)
26

Efeitos da operação do gerador de indução no comportamento do gerador síncrono operando em um sistema isolado alimentando cargas não lineares / Effects of the induction generator operation on the synchronous generator behavior operating on an isolated system feeding nonlinear loads

Oliveira, José Mário Menescal de 13 July 2018 (has links)
Submitted by Liliane Ferreira (ljuvencia30@gmail.com) on 2018-09-14T11:19:37Z No. of bitstreams: 2 Tese - José Mário Menescal de Oliveira - 2018.pdf: 3555364 bytes, checksum: 7da381c5690449c518f20f2a3fd49fea (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2018-09-17T10:48:33Z (GMT) No. of bitstreams: 2 Tese - José Mário Menescal de Oliveira - 2018.pdf: 3555364 bytes, checksum: 7da381c5690449c518f20f2a3fd49fea (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2018-09-17T10:48:33Z (GMT). No. of bitstreams: 2 Tese - José Mário Menescal de Oliveira - 2018.pdf: 3555364 bytes, checksum: 7da381c5690449c518f20f2a3fd49fea (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2018-07-13 / This thesis demonstrates the effects of harmonic pollution in a salient pole synchronous generator and an induction generator operating in parallel on an isolated system, supplying a non-linear load. The main contributions of this research-study consist of identifying and quantifying the oscillations that non-linear load cause on the electric variables of synchronous and induction generators, such as, the electromagnetic conjugate that presents oscillations of sixth harmonic due to the distorted currents. / Este trabalho mostra os efeitos da poluição harmônica em um gerador síncrono de polos salientes e um gerador de indução operando em paralelo em um sistema isolado suprindo carga não linear. As principais contribuições deste trabalho consistem em identificar e quantificar as oscilações que a carga não linear utilizada provoca nas variáveis elétricas dos geradores síncronos e dos geradores de indução, tal como, o conjugado eletromagnético que apresenta oscilações de sexto harmônico devido as correntes distorcidas.
27

Controle de tensão terminal e potência reativa de um grupo motor gerador diesel conectado à rede de distribuição / Terminal voltage control and reactive power of a powerplant diesel generator connected to the distribution network

Rodolpho Vilela Alves Neves 19 March 2013 (has links)
Este trabalho apresenta uma estratégia de controle coordenado para potência reativa e tensão terminal de um grupo moto gerador (GMG) para uso em um sistema de geração distribuída (GD). A partir da construção de uma superfície fuzzy, baseada no comportamento do erro e da derivada do erro de uma malha de controle, foi realizada a sintonia de controladores fuzzy PD+I para potências ativa e reativa e tensão terminal. O controlador coordenado fuzzy PD+I ajusta automaticamente a tensão nos terminais da máquina e a potência reativa fornecidas à rede de distribuição. A estratégia coordenada é dada através de um parâmetro que regula a malha de potência reativa a partir do erro de tensão terminal, priorizando o ajuste da tensão e ponderando a malha de controle de potência reativa. Para avaliar o desempenho do sistema de controle, a GD é conectada a uma rede de distribuição e submetida a eventos como entrada e saída de cargas locais. O conjunto de cargas locais é composto por um motor de indução, uma carga RLC e um retificador trifásico não controlado. Sete cenários foram simulados para avaliar a estratégia de controle em diferentes regimes de operação do GMG. Resultados para tensão terminal, fator de potência e fluxo de potências entre o sistema, as cargas e a rede, ilustram a eficiência da estratégia de controle apresentada. A estratégia de controle coordenado para potência reativa e tensão terminal se mostrou capaz de melhorar os índices de fator de potência controlando o fluxo de potência do barramento em que a GD estava conectada, sem prejudicar a tensão terminal do gerador, mantendo a GD em limites seguros de operação. / This work presents a coordinated control strategy to terminal voltage and reactive power for a diesel generation set used as a distributed gerenation system (DG). From desired control actions, a fuzzy surface was designed for fuzzy PD+I controllers. Fuzzy PD+I controllers automatically adjust the terminal voltage and the reactive power delivered to the grid. The coordinated control strategy weighs the control action for the reactive power through a variable parameter, prioritizing the terminal voltage adjustment. To illustrate the system control performance, the DG is connected to a grid dynamic model and the system is subjected to connection and disconnection of loads at the local bus. The local loads set was composed of an induction machine, a RLC load and an uncontrolled three-phase rectifier. Seven scenarios were simulated to evaluate the control strategy in different DG regime of operation. Results for terminal voltage, power factor and reactive power among the DG, the local loads and the grid, illustrates the control strategy efficiency improved the power factor by regulating the reactive power injected at the bus, maintaining the DG terminal voltage in safe operation limits.