• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 107
  • 21
  • 9
  • Tagged with
  • 141
  • 141
  • 141
  • 94
  • 94
  • 92
  • 59
  • 43
  • 32
  • 26
  • 24
  • 22
  • 19
  • 18
  • 17
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Análise das tensões geradas durante a contração de polimerização e aplicação de cargas em restaurações diretas de resina composta. Efeito da utilização de materiais para base ou forramento /

Oliveira, Luana Cristina Araújo de. January 2004 (has links)
Resumo: O objetivo desta investigação científica foi analisar o efeito da presença de materiais para base ou forramento, nas tensões geradas durante a contração de polimerização e aplicação de cargas, em cavidade classe I, no segundo pré-molar superior. Foram avaliadas quatro técnicas restauradoras: 1) Resina composta Z250(3M ESPE) controle, 2) Resina composta Z250(3M ESPE) + forramento com resina de baixa viscosidade FiltekFlow(3M ESPE), 3) Resina composta Z250(3M ESPE) + Forramento com ionômero de vidro modificado por resina Vitrebond(3M ESPE) e 4) Resina composta Z250(3M ESPE) + base com ionômero de vidro modificado por resina Vitrebond(3M ESPE). O estudo transcorreu em três fases: 1)Fotoelasticidade, 2)Tensilometria e 3)Elementos Finitos. 1ª Fase (Fotoelasticidade) - Nesta etapa foram avaliadas as tensões geradas durante a contração de polimerização na cavidade confeccionada em modelo fotoelástico, restaurada com as técnicas descritas acima, nomeadas F1, F2, F3 e F4 respectivamente e determinada a Tensão Cisalhante Máxima(tmáx ) na interface adesiva e realizados os Testes ANOVA e Tukey (p=0,05). 2ª Fase (Tensilometria) - Nesta etapa foram avaliadas as tensões geradas durante a contração de polimerização de cada material, assim agrupados: T1 - resina composta, T2 - resina de baixa viscosidade e T3 - Ionômero de vidro modificado por resina, os quais foram inseridos entre duas bases cilíndricas de dentina bovina (diâmetro 4,0 mm) com espessura de 2,0mm, sendo que a base superior foi conectada a uma célula de carga. Os valores de força foram registrados iniciando simultaneamente com a fotopolimerização até a completa estabilização das forças... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was analyze the effect of liner and base materials presence during polymerization shrinkage and load application, on cavities class I, in maxillary premolar. The following technique were assigned: 1) Composite resin Z250(3M ESPE)-control, 2) Composite resin Z250(3M ESPE) + liner with flowable FiltekFlow (3M ESPE) 3) Composite resin Z250(3M ESPE) + liner with resin-modified glass-ionomer Vitrebond(3M ESPE) e 4) Composite resin Z250(3M ESPE) + base with resin-modified glass-ionomer Vitrebond(3M ESPE). The study was divided in three phases: 1) Photoelasticity, 2) Tensilometry e 3) Finite Elements Analysis. 1ª (Photoelasticity) - In this phase was determinate polymerization shrinkage stress in photoelastic model, filled with techniques, named F1, F2, F3 e F4 respectively and Maximal Shear Stress (tmáx) was determinate along adhesive interface. Results were analyzes by Anova and Tukey Test. (p=0,05). 2ª (Tensilometry) - In this phase was determinate, polymerization shrinkage stress, for each material: T1 - composite resin, T2 - flowable resin e T3 - resin-modified glass-ionomer. Materials were inserted into 2mm space, between two dentin bovine cylindrical bases, (diameter 4,0mm), which one was connected a load cell. A curve ForceXTime, was obtained for each of samples. Results were analyzes by Anova and Tukey Test. (p=0,05). 3ª (Finite Elements Analysis) - In this phase, stresses resulting from polymerization shrinkage in combination with oclusal loading, were determinate in a 2D finite element model. The polymerization shrinkage stress was fundamented in Tensilometry and Phoelasticity results... (Complete abstract, click electronic access below) / Orientador: Sillas Luiz Lordelo Duarte Júnior / Coorientador: Welingtom Dinelli / Banca: José Roberto Cury Saad / Banca: Osmir Batista de Oliveira Júnior / Banca: Cleudmar Amaral de Araújo / Banca: Rafael Francisco Lia Mondelli / Doutor
42

Efeito da incorporação de nanopartículas de hexametafosfato de clorexidina em propriedades de um cimento de ionômero de vidro de alta viscosidade /

Souza, Ana Carolina Becci de. January 2017 (has links)
Orientador: Elisa Maria Aparecida Giro / Resumo: Lesões de cárie secundarias nas margens das restaurações tem sido a principal razão para a sua substituição. Portanto, o desenvolvimento de materiais com propriedades antibacterianas melhoradas e duradouras é desejável. O objetivo deste estudo foi avaliar a influência da incorporação de nanopartículas de hexametafosfato de clorexidina (NPs CLX-HMP) a um cimento de ionômero de vidro (CIV) de alta viscosidade, nas suas propriedades físico-químicas, mecânica e antibacteriana. Após a síntese e caracterização, as nanopartículas foram adicionadas ao CIV nas concentrações de 1%, 2% e 5%. O CIV sem adição de nanopartículas foi utilizado como controle. Espécimes cilíndricos (3mm x 6mm) foram confeccionados com os materiais (n=12/grupo) e mantidos em água deionizada por 30 dias. A liberação de CLX foi avaliada no eluato por espectrofotometria ultravioleta e a dosagem do flúor foi feita com auxílio de um eletrodo específico, nos períodos de 1 h e 1, 7, 15 e 30 dias. No 30º dia, os espécimes receberam uma aplicação tópica de flúor gel neutro 2% e a liberação de flúor foi reavaliada por mais 30 dias. Para avaliar a atividade antibacteriana, biofilmes polimicrobianos cresceram sobre espécimes dos materiais (n=10/grupo), utilizando um modelo de aderência ativa. Em seguida, foram coletados e inoculados em meios de cultura específicos para a quantificação de microrganismos totais, bactérias acidúricas totais e estreptococos do grupo mutans. A atividade metabólica foi analisada pelo ensaio de ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Secondary caries on the margins of restorations have been the main reason for their replacement. Therefore, the development of materials with improved and long-lasting antibacterial properties is desirable. The objective of this study was to evaluate the influence of the incorporation of chlorhexidine hexametaphosphate nanoparticles (CHX-HMP NPs) to a high viscosity glass ionomer cement (GIC) in its physicochemical, mechanical and antibacterial properties. After synthesis and characterization, the nanoparticles were added to the GIC at concentrations of 0%, 1%, 2% and 5%. Cylindrical specimens (3 mm x 6 mm) made with the materials were kept in deionized water for 30 days. The CHX release was evaluated in the eluate by ultraviolet spectrophotometry and the fluoride dosage was done with the help of a specific electrode, in the periods of 1 h and 1, 7, 15 and 30 days. On the 30th day, the specimens received a topical application of neutral fluorine gel 2% and the fluoride release was reevaluated for another 30 days. To evaluate the antibacterial activity, polymicrobial biofilms grew on the specimens of the materials, using an active adherence model. The biofilms formed were collected, inoculated in specific culture media and thereafter, the quantification of total microorganisms, total acid bacteria and streptococci of mutans group was made. The metabolic activity was analyzed by the XTT assay and the biomass by violet crystal staining. Finally, it was evaluated the bond strength of the material to the sound and caries-affected dentin, after 24 h and 6 months of storage of the specimens in artificial saliva, using the microshear test. The fracture patterns were evaluated with the aid of light microscope. Adequate statistical tests were applied according to the distribution of the data and the homogeneity of variances. The level of significance was set at 5%. The synthesized nanoparticles presented ...(complete abstract electronic access below) / Doutor
43

Influência da adição de fosfato octacálcico, alfa-fosfato tricálcico ou hidroxiapatita nas propriedades de um cimento de ionômero de vidro

Santos, Paula Dapper January 2015 (has links)
O protocolo moderno de tratamento da doença cárie está baseado na intervenção minimamente invasiva, que pode lançar mão da remoção parcial de tecido cariado para reduzir os riscos de problemas pós-operatórios. Por possuir capacidade de aderir aos subtratos dentários, os cimentos de ionômero de vidro apresentam indicação para esse processo. Em contrapartida, fosfatos cálcicos apresentam potencialidade de induzir deposição mineral. Sendo assim, o objetivo desse estudo foi avaliar o efeito da incorporação de fosfato octacálcico (OCP), α-fosfato tricálcico (α-TCP) ou hidroxiapatita (HA) sobre as propriedades de um cimento de ionômero de vidro comercial restaurador, bem como caracterizar a dentina bovina desmineralizada restaurada com esses materiais. Foram produzidos três grupos testes: GOCP, GTCP e GHA, por meio da substituição de 5% em massa do pó do cimento original, por 5% em massa de OCP, de α-TCP ou de HA, respectivamente. O grupo GCIV, sem alterações, foi o grupo controle. As propriedades avaliadas foram radiopacidade, tempo de presa inicial e profundidade de polimerização, de acordo com a ISO 9917-2:2010. A caracterização da dentina foi realizada através de microdureza Knoop e espectrocopia Raman, através da intensidade do pico 962 cm-1, para verificar-se a presença de fosfato no interior da dentina. Os resultados de radiopacidade foram equivalentes a 3 mmAl. O tempo de presa inicial variou entre 39,06 + 1,15 min, para o GCIV, e 58,39 + 2,64 min, para o GTCP. Na profundidade de polimerização, os valores variaram entre 1,61 + 0,04, para o GHA, e 1,77 + 0,04 mm, para o GTCP. Todos os resultados de radiopacidade, tempo de presa inicial e profundidade de polimerização foram de acordo com os preconizados pela norma. A dureza da dentina hígida foi superior tanto à dureza dos grupos que foram submetidos à restauração quanto à dureza da dentina desmineralizada. Mesmo sendo ilustrativas, as imagens obtidas da dentina dos diferentes grupos mostram intensidades variadas de fosfato, especialmente em relação à dentina hígida, permitindo inferir que, dentre os grupos desmineralizados, há maior intensidade no GHA. Pode-se concluir que a adição de fosfatos cálcicos não prejudicou as propriedades do cimento de ionômero de vidro comercial e que as imagens que representam a intensidade de fosfato no interior da dentina dos grupos sugerem que os materiais avaliados podem apresentar uma potencial ação indutora de deposição mineral. / The modern protocol for treating caries disease is based on minimal invasive intervention, which can employ incomplete caries removal, to reduce post-operatory problems. For bearing capacity to adhere to tooth substrate, the glass ionomer cement is indicated for this process. Furthermore, the calcium phosphates have potential to induce mineral deposition. Thus, the aim of this study was to evaluate the effect of the addition of octacalcium phosphate (OCP), αtricalcium phosphate (α-TCP), or nanostructured hydroxyapatite (HA) on the properties of commercial restorative glass ionomer cement, and to characterize demineralised bovine dentin restored with these materials. Three test groups were produced: GOCP, GTCP, and GHA, through the substitution of 5%, by mass, of original cement powder with 5%, by mass, of OCP, α-TCP or HA, respectively. The group GCIV, without alteration, was the control group. Radiopacity, initial hardening time, and depth of cure were the properties evaluated, all according to ISO 9917-2:2010. Dentin characterization was conducted using Knoop microhardness and Raman spectroscopy, through 962 cm-1 intensity peak, to verify phosphate existence in inner dentin. Radiopacity results were equivalent to 3 mmAl. Initial hardening time varied between 39.06 + 1.15 min, for GCIV, and 58.39 + 2.64 min, for GTCP. For depth of cure, values varied between 1.61 + 0.04 mm, for GHA, and 1.77 + 0.04 mm, for GTCP. All results of radiopacity, initial hardening time and depth of cure were according to what is established by the standard. Hard sound dentin values were superior both for restored groups hardness and for demineralised dentin hardness. Though illustrative, different groups dentin images show varied phosphate intensities, especially regarding sound dentin, allowing to infer that, among demineralised groups, there are higher intensity in GHA. Thus, it is possible to conclude that the addition of calcium phosphates did not impaired commercial glass ionomer cement properties and that groups images representing inner dentin phosphate intensity suggest that evaluated materials may present potential mineral deposition induction action.
44

Estudo in vitro do efeito antibacteriano de cimentos de ionômero de vidro incorporados com diacetato de clorexidina / In vitro study of the antimicrobial effect of glass ionomer cements incorporated with chlorhexidine diacetate

Renato Mayhé 19 February 2014 (has links)
O objetivo deste trabalho foi o de avaliar in vitro o efeito da ação antibacteriana de cimentos de ionômero de vidro (CIVs) convencionais incorporados com diacetato de clorexidina (DCHX) sobre o Streptococcus mutans. Foram testados os CIVs Maxxion R e Vitro Fil R com a incorporação dos percentuais de 0,5%, 1% e 2% de DCHX através de difusão em ágar e pela exaustão do DCHX por até 40 dias, a fim de observar a longevidade de sua ação inibitória. Foi também avaliado o efeito do fluoreto de sódio na ação antibacteriana do DCHX. Para determinar a diferença entre a média dos halos de inibição Os resultados foram analisados por análise de variância e pelo teste Student-Newman-Keuls (SNK). Todos os corpos de prova com DCHX apresentaram halo para os CIVs variando de 2,29mm a 6,82mm para o Maxxion R e de 1,73mm a 8,97mm para o Vitro Fil R. A capacidade de inibição foi proporcional à concentração de DCHX. Através do teste SNK apenas os grupos Vitro Fil R 0,5% e1% não variaram significativamente entre si. O 15o dia foi o de maior atividade antibacteriana para ambos os CIVs. Os grupos Maxxion R 1% e 2% foram os que menos apresentaram diferenças ao longo do tempo. Não houve crescimento de S mutans para os períodos de 7 e 15 dias de exaustão, sendo verificado o crescimento de colônias apenas na superfície do meio após o período de 96hs de incubação. Não foi observado efeito antagônico na capacidade antibacteriana do DCHX na presença de fluoreto de sódio. A incorporação de DCHX aos CIVs Maxxion R e Vitro Fil R, nas concentrações testadas e por um período de até 40 dias, apresentam resultados positivos no controle bacteriano de S mutans. Dentro das limitações deste estudo é lícito concluir que: efeito da inibição ao S mutans é dependente da concentração do DCHX; o fluoreto por si só não é capaz de inibir o crescimento de S mutans; a associação do DCHX com os CIVs não alterou a capacidade da ação antibacteriana da CHX; a ação antibacteriana da CHX incorporada aos CIVs se mantém eficaz por 15 dias, independente do CIV testado. / The purpose of this study was to evaluate (the in vitro the effect) of antibacterial action of conventional glass ionomer cements (GICs glass ionomer cements) incorporated with chlorhexidine diacetate (DCHX) on Streptococcus mutans. We tested the GICs Maxxion Vitro Fil R & R with the incorporation of the percentage of 0.5%, 1% and 2% DCHX by agar diffusion and the depletion of DCHX by up to 15 days to observe the longevity of its inhibitory action. It was also evaluated the effect of sodium fluoride on the antibacterial action of DCHX. To determine the difference between the mean of the inhibition zones, the results were analyzed by analysis of variance and the Student-Newman-Keuls test (SNK). All specimens presented with DCHX halo for GICs ranging from 2.29 mm to 6.82 mm for Maxxion R and 1.73 mm to 8.97 mm for the FIL Vitro R. The inhibition capacity were proportional to the concentration of DCHX. Through the SNK test only groups Vitro Fil R 0.5% e1% did not vary significantly. The 15th day was the one with highest antibacterial activity for both GICs. The R Maxxion 1% and 2% were the groups with less differences over time. No growth was observed of S. mutans for periods of 7 and 15 days of exhaustion, with observed growth of colonies only on the surface of the culture media after 96 hours of incubation period. No antagonistic effect was observed in the ability of the antibacterial DCHX in the presence of sodium fluoride. Incorporating DCHX GICs Maxxion Vitro Fil R & R, in tested concentrations and for a period up to 40 days showed a positive bacterial control of S. mutans. Despite the limitations of this study, we may conclude that: inhibition effect of S. mutans is dependent on the concentration of DCHX; fluoride alone is not able to inhibit growth of S. mutans; the association of DCHX with VSDs did not alter the capacity of the antibacterial action of CHX and the antibacterial action of CHX incorporated into GICs remains effective for 15 days, regardless of the GIC tested.
45

Efeito da incorporação do trimetafosfato de sódio microparticulado e nanoparticulado ao cimento de ionômero de vidro nas propriedades físico-mecânicas e na desmineralização do esmalte

Abreu, Valéria Marisel de [UNESP] 28 August 2015 (has links) (PDF)
Made available in DSpace on 2016-02-05T18:30:10Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-08-28. Added 1 bitstream(s) on 2016-02-05T18:34:20Z : No. of bitstreams: 1 000857869.pdf: 2789826 bytes, checksum: cecfa33b798ebbee35330f861246deea (MD5) / O objetivo do presente estudo foi avaliar o efeito da incorporação do trimetafosfato de sódio (TMP) microparticulado (m) e nanoparticulado (n) ao cimento de ionômero de vidro (CIV) nas propriedades físico-mecânicas e na desmineralização do esmalte. Foram confeccionados corpos-de-prova (n=54) para cada grupo experimental: CIV sem TMP (CIV), CIV com TMPm 3,5%, 7% e 14% e CIV com TMPn 3,5%, 7% e 14%. Seis corposde- prova foram utilizados na determinação da liberação de fluoreto (F) e TMP em soluções de desmineralização e de remineralização durante 15 dias. As propriedades físico-mecânicas avaliadas 24 horas e 7 dias após a confecção foram: resistência à compressão (n=12), resistência à tração diametral (n=12), dureza de superfície do material (n=6) e grau de conversão de monômeros (n=6). Para o estudo da desmineralização do esmalte, corpos-de-prova (n=12) foram adaptados a blocos de esmalte selecionados pelo teste de dureza de superfície inicial (DS1) e submetidos às ciclagens de pH. A seguir, determinou-se a dureza de superfície final (DS2), em secção longitudinal (DSL) e a concentração de F no esmalte. Testes paramétricos e não paramétricos foram realizados, após a verificação da homocedasticidade dos dados (p<0,05). A adição de 14% de TMP levou a maior média de liberação de F (p<0,05) e os demais grupos foram similares ao CIV (p>0,05). Maior liberação de TMP foi observada com 14% microparticulado (p<0,05). A incorporação do TMP ao CIV promoveu uma redução média nas propriedades mecânicas de 21% (tração), 10% (compressão) e 18% (dureza), após 24 horas e em 18%, 23% e 12%, após 7 dias. O grau de conversão foi menor com adição de 14% TMP quando comparado ao CIV após 24 horas (p<0,05); no tempo de 7 dias não houve diferença entre os grupos (p>0,05). A adição de 7% e 14% de... / The aim of this study was to evaluate the effect of addition of sodium trimetaphosphate (TMP) microparticle (m) and nanoparticle (n) to the glass ionomer cement (GIC) on the physico-mechanical properties and demineralization of the enamel. Specimens (n=54) were fabricated from each experimental group: GIC without TMP (GIC), GIC with 3.5%, 7% and 14% TMPm and GIC with 3.5%, 7% and 14% TMPn. To determine the release of fluoride (F) and TMP it was used six specimens immersed into a demineralization and remineralization solution during 15 days. The physico-mechanical properties evaluated 24 hours and 7 days after fabrication were: compressive strength (n=12), diametral tensile strength (n=12), surface hardness of material (n=6) and the degree of conversion of monomers (n=6). For the study of enamel demineralization, specimens (n=12) were attached to enamel blocks selected by the initial surface hardness test (SH1) and submitted to the pH-cycling. Following, final surface (SH2) and cross-sectional (CSH) hardness, as well as enamel F concentration were determined. Parametric and non-parametric tests were performed after checking the data homoscedasticity (p<0.05). The addition of 14% TMP led to higher mean release of F (p<0.05) and the other groups were similar to the GIC (p>0.05). The release of TMP was higher with 14% microparticulate (p<0.05). The addition of TMP at GIC promoted an average reduction of mechanical properties of 21% (tensile), 10% (compressive) and 18% (hardness) after 24 hours and 18%, 23% and 12% after 7 days. The degree of conversion was lower with addition of 14% TMP compared to the GIC after 24 hours (p<0.05); at 7 days there was no difference between groups (p>0.05). Addition of 7% and 14% TMP reduced mineral loss and increased enamel F concentration when compared...
46

Efeito da ciclagem de ph erosiva nas propriedades mecânicas da dentina utilizando diferentes materiais restauradores

Guedes, Ana Paula Albuquerque [UNESP] 26 July 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:25Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-07-26Bitstream added on 2014-06-13T20:41:41Z : No. of bitstreams: 1 000737081.pdf: 1574523 bytes, checksum: 5bd18c418b9c0819dc40248db7d21062 (MD5) / O objetivo deste estudo in vitro foi avaliar o efeito da ciclagem de pH erosiva com soluções que simulam a erosão dental, provenientes de fatores extrínsecos ou intrínsecos, na dureza e módulo de elasticidade da dentina restaurada com materiais restauradores contendo fluoretos. Quarenta e cinco blocos de dentina medindo 6 x 6 mm foram restaurados com cinco materiais restauradores: sistema adesivo de condicionamento total Adper Single Bond 2 + resina composta Filtek Z250; sistema adesivo autocondicionante One Up Bond F + resina composta Filtek Z250; sistema adesivo autocondicionante Clearfil SE Protect + resina composta Filtek Z250; cimento de ionômero de vidro convencional Riva Self Cure; cimento de ionômero de vidro resinoso Riva Light Cure. Mensurações da dureza Martens e módulo de elasticidade da dentina subjacente à interface de união (10μm, 30μm, 50μm e 70μm) foram realizadas em ultramicrodurômetro digital antes e após a imersão em soluções de água deionizada, ácido cítrico ou ácido clorídrico. Após a ciclagem, os valores de dureza da dentina diminuíram para todos os materiais. Para a dentina restaurada com Adper Single Bond 2, os menores valores foram encontrados próximo a camada híbrida (10 μm) enquanto que para a dentina restaurada com os sistemas adesivos autocondicionantes (Clearfil SE Protect e One Up Bond F), esses valores foram mantidos em todas as distâncias avaliadas. Para os materiais Riva Self Cure e Riva Light Cure somente nas leituras iniciais a distância foi determinante na dureza, uma vez que quanto maior a distância da interface de união, maiores eram os valores encontrados. Com relação ao módulo de elasticidade, para a dentina restaurada com Adper Single Bond 2, não houve diferença significante em todas as distâncias avaliadas. Já na dentina restaurada com os sistemas adesivos autocondicionantes... / The aim of this study was to evaluate the effect of erosive pH cycling with solutions that simulate dental erosion in the hardness and elastic modulus of dentin restored with fluoride-releasing restorative materials. Forty five bovine dentine slabs (6,0 mm x 6,0 mm) were restored with 5 restorative materials: Adper Single Bond 2 total-etch adhesive system + Filtek Z250 composite resin; One Up Bond F self-etching adhesive system + Filtek Z250 composite resin; Clearfil SE Protect self-etching adhesive system + Filtek Z250 composite resin; Riva Self Cure conventional glass ionomer cement and Riva Light Cure light curing glass ionomer cement. The values of hardness and elastic modulus of dentin (10μm, 30μm, 50μm e 70μm) were evaluated in digital ultramicrohardner tester before and after immersion in solutions of deionized water, citric acid and hydrochloric acid. After cycling, the hardness of dentin decreased for all materials. For dentin restored with Adper Single Bond 2, the lowest values were found close to hybrid layer (10 μm), while for the dentin restored with One Up Bond F and Clearfil SE Protect, the values remained unaltered in all the evaluated distances. For dentin restored with Riva Self Cure and Riva Light Cure only in the initial measurements, the distance had a significant effect in the hardness values, since the greater the distance to the bonding interface, higher values of hardness were found. For the elastic modulus analysis, dentin restored with Adper Single Bond 2 showed no significant difference when distances from bonding interface were compared. Dentin restored with self-etching adhesive system (One Up Bond F and Clearfil SE Protect) and glass ionomer cements (Riva Self Cure and Riva Light Cure) showed a reduction in the elastic modulus values from the bonding interface, but after 30 μm the difference was not significant.
47

Análise das tensões geradas durante a contração de polimerização e aplicação de cargas em restaurações diretas de resina composta. Efeito da utilização de materiais para base ou forramento

Oliveira, Luana Cristina Araújo de [UNESP] 26 June 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:26Z (GMT). No. of bitstreams: 0 Previous issue date: 2004-06-26Bitstream added on 2014-06-13T21:02:28Z : No. of bitstreams: 1 oliveira_lca_dr_arafo.pdf: 2273954 bytes, checksum: 3107451a04bf448e6e343be28108c606 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo desta investigação científica foi analisar o efeito da presença de materiais para base ou forramento, nas tensões geradas durante a contração de polimerização e aplicação de cargas, em cavidade classe I, no segundo pré-molar superior. Foram avaliadas quatro técnicas restauradoras: 1) Resina composta Z250(3M ESPE) controle, 2) Resina composta Z250(3M ESPE) + forramento com resina de baixa viscosidade FiltekFlow(3M ESPE), 3) Resina composta Z250(3M ESPE) + Forramento com ionômero de vidro modificado por resina Vitrebond(3M ESPE) e 4) Resina composta Z250(3M ESPE) + base com ionômero de vidro modificado por resina Vitrebond(3M ESPE). O estudo transcorreu em três fases: 1)Fotoelasticidade, 2)Tensilometria e 3)Elementos Finitos. 1ª Fase (Fotoelasticidade) - Nesta etapa foram avaliadas as tensões geradas durante a contração de polimerização na cavidade confeccionada em modelo fotoelástico, restaurada com as técnicas descritas acima, nomeadas F1, F2, F3 e F4 respectivamente e determinada a Tensão Cisalhante Máxima(tmáx ) na interface adesiva e realizados os Testes ANOVA e Tukey (p=0,05). 2ª Fase (Tensilometria) - Nesta etapa foram avaliadas as tensões geradas durante a contração de polimerização de cada material, assim agrupados: T1 - resina composta, T2 - resina de baixa viscosidade e T3 - Ionômero de vidro modificado por resina, os quais foram inseridos entre duas bases cilíndricas de dentina bovina (diâmetro 4,0 mm) com espessura de 2,0mm, sendo que a base superior foi conectada a uma célula de carga. Os valores de força foram registrados iniciando simultaneamente com a fotopolimerização até a completa estabilização das forças... / The aim of this study was analyze the effect of liner and base materials presence during polymerization shrinkage and load application, on cavities class I, in maxillary premolar. The following technique were assigned: 1) Composite resin Z250(3M ESPE)-control, 2) Composite resin Z250(3M ESPE) + liner with flowable FiltekFlow (3M ESPE) 3) Composite resin Z250(3M ESPE) + liner with resin-modified glass-ionomer Vitrebond(3M ESPE) e 4) Composite resin Z250(3M ESPE) + base with resin-modified glass-ionomer Vitrebond(3M ESPE). The study was divided in three phases: 1) Photoelasticity, 2) Tensilometry e 3) Finite Elements Analysis. 1ª (Photoelasticity) - In this phase was determinate polymerization shrinkage stress in photoelastic model, filled with techniques, named F1, F2, F3 e F4 respectively and Maximal Shear Stress (tmáx) was determinate along adhesive interface. Results were analyzes by Anova and Tukey Test. (p=0,05). 2ª (Tensilometry) - In this phase was determinate, polymerization shrinkage stress, for each material: T1 - composite resin, T2 - flowable resin e T3 - resin-modified glass-ionomer. Materials were inserted into 2mm space, between two dentin bovine cylindrical bases, (diameter 4,0mm), which one was connected a load cell. A curve ForceXTime, was obtained for each of samples. Results were analyzes by Anova and Tukey Test. (p=0,05). 3ª (Finite Elements Analysis) - In this phase, stresses resulting from polymerization shrinkage in combination with oclusal loading, were determinate in a 2D finite element model. The polymerization shrinkage stress was fundamented in Tensilometry and Phoelasticity results... (Complete abstract, click electronic access below)
48

Propriedades antimicrobianas, físico-mecânicas e de liberação de fluoreto do cimento de ionômero de vidro associado ao hexametafosfato de sódio microparticulado e nanoparticulado

Hosida, Thayse Yumi [UNESP] 25 February 2015 (has links) (PDF)
Made available in DSpace on 2015-06-17T19:34:29Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-02-25. Added 1 bitstream(s) on 2015-06-18T12:48:45Z : No. of bitstreams: 1 000830085.pdf: 704356 bytes, checksum: fbb6f56d09478a8adc55d7eb2addad71 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / O objetivo do presente estudo foi avaliar as propriedades antimicrobianas, físico-mecânicas e de liberação de fluoreto do cimento de ionômero de vidro (CIV) associado ao hexametafosfato de sódio (HMP) microparticulado e nanoparticulado. Inicialmente, foram obtidas soluções de HMP nas concentrações 1, 3, 6, 9 e 12 % e a atividade antibacteriana foi avaliada contra Streptococcus mutans, Lactobacillus acidophilus e Actinomyces israelli por meio do teste de difusão em ágar. A mesma metodologia foi empregada para determinar a atividade antimicrobiana do CIV associado ao HMP nas concentrações de 6, 9 e 12 % microparticulado ou nanoparticulado. Foi determinada a liberação de fluoreto (F) e HMP em soluções de desmineralização e remineralização. Além disso, as resistências à tração diametral e compressão, dureza de superfície e grau de conversão de monômeros foram analisados. Testes paramétricos e não paramétricos foram realizados, após a verificação da homocedasticidade dos dados (p < 0,05). As soluções de 6, 9 e 12 % de HMP apresentaram melhor atividade antimicrobiana contra as bactérias testadas, sendo essas concentrações incorporadas ao CIV. Todas as concentrações de HMP associado ao CIV tiveram atividade antimicrobiana para todas as bactérias. Observou-se uma relação dose-resposta entre concentração de HMP no CIV e a atividade antimicrobiana. Com relação à liberação de F e HMP, os maiores valores ocorreram no primeiro dia em todos os grupos e as maiores médias de liberação ocorreram nos grupos contendo 9 e 12 % de HMP nanoparticulado. Entretanto, a incorporação do HMP ao CIV reduziu as propriedades físico-mecânicas quando comparado ao CIV mostrando uma relação dose-resposta. Concluiu-se que a incorporação de HMP no CIV melhora a atividade antimicrobiana e aumenta a liberação de F, porém reduz suas... / The aim of this study was to evaluate antimicrobial, physico-mechanical and fluoride release properties of the glass ionomer cement (GIC) associated with HMP microparticle and nanoparticle. Initially, solutions of HMP were obtained at concentrations of 1, 3, 6, 9 and 12 %, and the antibacterial activity was evaluated against Streptococcus mutans, Lactobacillus acidophilus and Actinomyces israelli by agar diffusion test. The same methodology was used to determine the antimicrobial activity of GIC associated with HMP at concentrations of 6, 9 and 12 % microparticle or nanoparticle. The release of F and HMP were determined in demineralization and remineralization solutions. Furthermore, the resistance to diametral tensile and compression, surface hardness and the degree of conversion of monomers were measured. Parametric and non-parametric tests were performed, after checking homocedasticity data (p < 0.05). The solutions of 6, 9 and 12 % of HMP showed better antimicrobial activity against all bacteria tested, and these concentrations incorporated into the CIV. All concentrations of HMP incorporated into the GIC had antimicrobial activity for all bacteria. There was a dose-response relationship between concentration of HMP in the GIC and antimicrobial activity. Regarding the release of F and HMP, higher values occurred on the first day in all groups and the highest levels of release occurred in groups containing 9 and 12 % of HMP nanoparticle. However the incorporation of HMP in the GIC reduced values of physical and mechanical tests when compared to the GIC, showing a dose-response relationship. It was concluded that the incorporation of HMP in GIC improves antimicrobial activity and increase the release of fluoride, but reduces its physical and mechanical properties. The reduction of particulate HMP led to better antimicrobial and fluoride release results
49

Efeito da ciclagem de ph erosiva nas propriedades mecânicas da dentina utilizando diferentes materiais restauradores /

Guedes, Ana Paula Albuquerque. January 2013 (has links)
Orientador: Paulo Henrique dos Santos / Banca: André Luiz Fraga Briso / Banca: Renato Herman Sundfeld / Banca: Cláudia Batitucci dos Santos Daroz / Banca: Anderson Catelan / Resumo: O objetivo deste estudo in vitro foi avaliar o efeito da ciclagem de pH erosiva com soluções que simulam a erosão dental, provenientes de fatores extrínsecos ou intrínsecos, na dureza e módulo de elasticidade da dentina restaurada com materiais restauradores contendo fluoretos. Quarenta e cinco blocos de dentina medindo 6 x 6 mm foram restaurados com cinco materiais restauradores: sistema adesivo de condicionamento total Adper Single Bond 2 + resina composta Filtek Z250; sistema adesivo autocondicionante One Up Bond F + resina composta Filtek Z250; sistema adesivo autocondicionante Clearfil SE Protect + resina composta Filtek Z250; cimento de ionômero de vidro convencional Riva Self Cure; cimento de ionômero de vidro resinoso Riva Light Cure. Mensurações da dureza Martens e módulo de elasticidade da dentina subjacente à interface de união (10μm, 30μm, 50μm e 70μm) foram realizadas em ultramicrodurômetro digital antes e após a imersão em soluções de água deionizada, ácido cítrico ou ácido clorídrico. Após a ciclagem, os valores de dureza da dentina diminuíram para todos os materiais. Para a dentina restaurada com Adper Single Bond 2, os menores valores foram encontrados próximo a camada híbrida (10 μm) enquanto que para a dentina restaurada com os sistemas adesivos autocondicionantes (Clearfil SE Protect e One Up Bond F), esses valores foram mantidos em todas as distâncias avaliadas. Para os materiais Riva Self Cure e Riva Light Cure somente nas leituras iniciais a distância foi determinante na dureza, uma vez que quanto maior a distância da interface de união, maiores eram os valores encontrados. Com relação ao módulo de elasticidade, para a dentina restaurada com Adper Single Bond 2, não houve diferença significante em todas as distâncias avaliadas. Já na dentina restaurada com os sistemas adesivos autocondicionantes ... / Abstract: The aim of this study was to evaluate the effect of erosive pH cycling with solutions that simulate dental erosion in the hardness and elastic modulus of dentin restored with fluoride-releasing restorative materials. Forty five bovine dentine slabs (6,0 mm x 6,0 mm) were restored with 5 restorative materials: Adper Single Bond 2 total-etch adhesive system + Filtek Z250 composite resin; One Up Bond F self-etching adhesive system + Filtek Z250 composite resin; Clearfil SE Protect self-etching adhesive system + Filtek Z250 composite resin; Riva Self Cure conventional glass ionomer cement and Riva Light Cure light curing glass ionomer cement. The values of hardness and elastic modulus of dentin (10μm, 30μm, 50μm e 70μm) were evaluated in digital ultramicrohardner tester before and after immersion in solutions of deionized water, citric acid and hydrochloric acid. After cycling, the hardness of dentin decreased for all materials. For dentin restored with Adper Single Bond 2, the lowest values were found close to hybrid layer (10 μm), while for the dentin restored with One Up Bond F and Clearfil SE Protect, the values remained unaltered in all the evaluated distances. For dentin restored with Riva Self Cure and Riva Light Cure only in the initial measurements, the distance had a significant effect in the hardness values, since the greater the distance to the bonding interface, higher values of hardness were found. For the elastic modulus analysis, dentin restored with Adper Single Bond 2 showed no significant difference when distances from bonding interface were compared. Dentin restored with self-etching adhesive system (One Up Bond F and Clearfil SE Protect) and glass ionomer cements (Riva Self Cure and Riva Light Cure) showed a reduction in the elastic modulus values from the bonding interface, but after 30 μm the difference was not significant. / Doutor
50

Avaliação de materiais restauradores ionoméricos, empregando a técnica do ART

Fernandes, Adriana Beatriz Silveira Pinto [UNESP] January 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:45Z (GMT). No. of bitstreams: 0 Previous issue date: 2004Bitstream added on 2014-06-13T20:36:13Z : No. of bitstreams: 1 fernandes_absp_me_araca.pdf: 2346845 bytes, checksum: f5101690e1608a466dec96035c51358b (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação para o Desenvolvimento da UNESP (FUNDUNESP) / Este estudo teve como objetivo avaliar a interação dos materiais ionoméricos com a dentina, na remoção do tecido cariado, empregando a técnica convencional e a do ART. De um total de 109 dentes, 13 ficaram para controle, 48 foram preparados pela técnica convencional, G I, e os outros 48 pela técnica do ART, G II. Após o preparo das cavidades, os espécimes foram aleatoriamente divididos em 03 subgrupos de acordo com o material restaurador ionomérico empregado: KETAC FILL para G I 1 e G II 1, VIDRION R para G I 2 e G II 2 e FUJI II LC para G I 3 e G II 3, todos com 16 dentes em cada subgrupo. Em cada subgrupo experimental, 06 dentes foram avaliados macroscopicamente e os outros 10, microscopicamente. Para a análise macroscópica, a parte radicular de 36 espécimes restaurados e de 03 espécimes controle foi incluída em resina, e o dente cortado em fatias. Cada fatia foi analisada em lupa estereoscópica a um aumento de 60 vezes. Para a análise microscópica, os 60 dentes preparados e os outros 10 cariados foram descalcificados em solução de EDTA, desidratados e submetidos a banhos de parafina, cortados a uma espessura de 6 micrometros, corados pelo método de Brown & Brenn, e avaliados em microscopia óptica. Os resultados na macroscopia revelaram uma boa adaptação dos materiais à superfície dentinária, pós remoção do tecido cariado; sugerindo semelhança de comportamento quando considerada a técnica de remoção de dentina cariada: convencional e ART. Quando considerado os materiais ionoméricos a avaliação da interface demonstrou um melhor comportamento dos ionômeros FUJI II LC e KETAC FILL em relação ao VIDRION R. Na análise microscópica somente com o FUJI II LC foi possível observar interação do material com a estrutura dentinária, revelando ainda supremacia de comportamento quando se utilizou a técnica convencional em relação a técnica do ART. / This study evaluated the interaction between glass ionomer materials and dentine using the convencional technique and ART in the remotion of decayed tissue. One hundred and nine teeth were used, 13 as control, 48 prepared by the conventional technique (group I) and the other 48 by ART technique (group II). After preparation of the cavites, the specimens were divided in 3 subgroups according to the glass ionomer material used: KETAC FILL for groups G I 1 and G II 1, VIDRION R for groups G I 2 and G II 2 and FUJI II LC for groups G I 3 and G II 3, all with 16 teeth in each subgroup. In each experimental subgroup, 6 teeth were evaluated macroscopically and the other 10, microscopically. For the macroscopic analysis, the root of 36 restored specimens and 3 control specimens were included in resin and the tooth was divided in slices. Each slice was analyzed in a stereoscopic magnifying glass at 60 times magnifying power. For the macroscopic analysis, the 60 prepared teeth and the other 10 decayed ones were decalcified in EDTA solution, dehydrated and subjected to parafine baths, cutt with 6 μm thickness, stained by the Brown & Brenn method, and evaluated in a light microscope. The results of the macroscopic analysis showed a good adaptation of the materials to dentine surface, after remotion of decayed tissue, suggesting similarity of behavior when considering the technique of decayed dentine remotion: conventional and ART. When considering ionomer materials, the evaluation of the interface showed a better behavior of FUJI II LC and KETAC FILL in comparison to VIDRION R. In the microscopic analysis, it was possible to observe the interaction between the material and dentine structure only with FUJI II LC, showing the supremacy of behavior when using the conventional technique in comparison to ART technique.

Page generated in 0.1123 seconds