• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 17
  • 15
  • 14
  • 12
  • 6
  • 3
  • Tagged with
  • 67
  • 30
  • 21
  • 18
  • 13
  • 10
  • 10
  • 10
  • 10
  • 10
  • 10
  • 9
  • 8
  • 8
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Analýza retinálních snímků se zaměřením na detekci vrstvy nervových vláken / Analysis of Retinal Images Aimed to Nerve Fiber Layer Detection

Spáčil, Michal January 2011 (has links)
Goal of this work is to theoretically develop and then program a system in Matlab environment to be used as a detection tool for layer of retinal neuron pathways . First part engages oneself upon the problem of analysis within spectral plane and results of using filters conceived upon statistical occurrences of certain frequencies in used samples. Second part than deals with use of gabor filters to detect neuron pathways and the statistical results gained by their use. Based on the results an analysis tool was programmed.
62

Multimodální registrace obrazů sítnice / Multimodal retinal image registration

Štohanzlová, Petra January 2011 (has links)
This work deals with possibilities of registration of retinal images from different mo-dalities, concretely optical coherence tomography (OCT), scanning laser ophthalmoscopy (SLO) and fundus camera. In first stage is the interest focused on registration of SLO and fundus images, which will serve to determine area of interest for consecutive registration of OCT data. The final stage is finding correct location of OCT B-scans in fundus image. On the basis of the studied methods of registration was chosen method making use of computation of correlation coefficient for both cases. For finding optimal parameters of registration is used searching through whole space of parameters. In partial stages of the work was created algorithm for alignment of B-scans followed by detection of blood vessels and also simple algorithm for detection of blood vessels from fundus image. For more transparent registration the graphical user interface was created, which allows loading input images and displaying the result in several possible forms.
63

Analýza vrstvy nervových vláken pro účely diagnostiky glaukomu / Analysis of retinal nerve fiber layer for diagnosis of glaucoma

Vodáková, Martina January 2013 (has links)
The master thesis is focused on creating a methodology for quantification of the nerve fiber layer on photographs of the retina. The introductory part of the text presents a medical motivation of the thesis and mentions several studies dealing with this issue. Furthermore, the work describes available textural features and compares their ability to quantify the thickness of the nerve fiber layer. Based on the described knowledge, the methodology to make different regression models enabling prediction of the retinal nerve fiber layer thickness was developed. Then, the methodology was tested on the available image dataset. The results showed, that the outputs of regression models achieve a high correlation between the predicted output and the retinal nerve fiber layer thickness measured by optical coherence tomography. The conclusion discusses an usability of the applied solution.
64

Analýza obrazových dat sítnice pro podporu diagnostiky glaukomu / Analysis of Retinal Image Data to Support Glaucoma Diagnosis

Odstrčilík, Jan January 2014 (has links)
Fundus kamera je široce dostupné zobrazovací zařízení, které umožňuje relativně rychlé a nenákladné vyšetření zadního segmentu oka – sítnice. Z těchto důvodů se mnoho výzkumných pracovišť zaměřuje právě na vývoj automatických metod diagnostiky nemocí sítnice s využitím fundus fotografií. Tato dizertační práce analyzuje současný stav vědeckého poznání v oblasti diagnostiky glaukomu s využitím fundus kamery a navrhuje novou metodiku hodnocení vrstvy nervových vláken (VNV) na sítnici pomocí texturní analýzy. Spolu s touto metodikou je navržena metoda segmentace cévního řečiště sítnice, jakožto další hodnotný příspěvek k současnému stavu řešené problematiky. Segmentace cévního řečiště rovněž slouží jako nezbytný krok předcházející analýzu VNV. Vedle toho práce publikuje novou volně dostupnou databázi snímků sítnice se zlatými standardy pro účely hodnocení automatických metod segmentace cévního řečiště.
65

OCT (Optical Coherense Tomography) : Teknik och tillämpning

Lundkvist, Stefan January 2013 (has links)
Before year 1895, the doctors could only make a probable diagnosis based on what the patient could tell and it was hurt and there was no discernable change to the outside of the body. With X-ray, it was possible to see inside the patient without first cutting it, you can say that the X-ray was the starting point for diagnostic imaging.The further development of X-ray gave CT (Computed Tomography), where X-ray tubes and detectors rotate around the patient while the patient table moves. Besides CT also developed MRI (Magnetic Resonance Imaging), PET (Positron Emission Tomography) and Ultrasound. Common to these methods is that the produced 3D images.In 1990 a completely new approach for diagnostic imaging, OCT (optical coherence tomography), by measuring the phase shift and the intensity of reflected light, it provides real-time and non-destructive measurements (in vivo) a resolution of 1 to 15 microns, much higher than all other standard imaging techniques. You could say that OCT machine can be compared to ultrasound, which uses the reflection of sound waves to interpretation.The first OCT machines were of type TD (Time Domain), these had low resolution and low scanning speed. In 2005 came the SD-OCT, they had higher resolution and scanning speed, SD stands for spectral domain, SD-OCT is sometimes called FD-OCT as Fourier transformed signals and operating in the frequency domain.The development of OCT machines are only in their infancy, resolution, scanning speed and accuracy will increase all the time, this allows new uses and ways to diagnose developed. OCT can be used in such Oncology, MSD (Musculoskeletal disorders), cardiovascular medicine, teeth, nerves, but the largest field is the eye and then the back of the eye called the retina (retina).This thesis is limited to the eye, the purpose is to provide input to those who are likely to purchase an OCT-machine, but also show the measurement data OCT-machines are performing and how to use the OCT-machine more than to see age-related macular degeneration. Another aim is to increase understanding of the physics behind an OCT-machine for ease of understanding the output given.The manufacture/model that have selected for evaluation are Zeiss Cirrus 4000, Topcon 3D OCT-2000 and Heidelberg Spectralis, the reason is that there are only these three on the Swedish market and all are SD-OCT. The way to evaluate OCT-machines is to scan performance and what the various analysis programs can handle. Furthermore, each OCT-machine scans the macula and optic disk on a experimental person/ reference eye, in order to get the output of the precision, or if you want to call it repeatability, which is very important if one wants to follow a solitary disease course.The conclusion of this thesis is to OCT machines are quite similar. When it comes to ease of use when doing scans is the Cirrus is lightened by the use of the extra screen where you always look eye (iris camera), which makes it easy to adjust the sharpness and position of the mouse buttons. Topcon and Heidelberg is not difficult to use but requires more experience of the person making the OCT scans. Most measurement functions in the analysis program is Topcon and Heidelberg and best accuracy/repeatability is Heidelberg, both the macula and RFNL.OCT machine is a good tool to use on the anterior segment, but in the case the precision allows the precision used to monitor RNFL thickness changes in those with glaucoma. / <p>Validerat; 20131029 (global_studentproject_submitter)</p>
66

Obrazový databázový systém pro podporu diagnostiky glaukomu / Image database system for glaucoma diagnosis support

Peter, Roman January 2008 (has links)
Tato práce popisuje přehled standardních a pokročilých metod používaných k diagnose glaukomu v ranném stádiu. Na základě teoretických poznatků je implementován internetově orientovaný informační systém pro oční lékaře, který má tři hlavní cíle. Prvním cílem je možnost sdílení osobních dat konkrétního pacienta bez nutnosti posílat tato data internetem. Druhým cílem je vytvořit účet pacienta založený na kompletním očním vyšetření. Posledním cílem je aplikovat algoritmus pro registraci intenzitního a barevného fundus obrazu a na jeho základě vytvořit internetově orientovanou tři-dimenzionální vizualizaci optického disku. Tato práce je součásti DAAD spolupráce mezi Ústavem Biomedicínského Inženýrství, Vysokého Učení Technického v Brně, Oční klinikou v Erlangenu a Ústavem Informačních Technologií, Friedrich-Alexander University, Erlangen-Nurnberg.
67

Software pro zpracování retinálních snímků / Software for retinal image processing

Magula, Filip January 2010 (has links)
This thesis deals with practical solutions of software for retinal images digital processing. The theoretic part describes human eye and retinal anatomy and also glaucoma disease. It is also focused on description of method for retinal nerve fiber layer enhancement and analysis. These enhancement are then used for designing of automated image processing. One chapter is devoted to detection and analysis of retinal nerve fibers layer. The practical part includes the user manual for application Image Blockz, which was established within this thesis. Further practical part contains the programmer's manual describing the basic structure of the program and its possible extensions.

Page generated in 0.033 seconds