• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • 2
  • 1
  • Tagged with
  • 6
  • 6
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Contribution à l'économie d'énergie dans le bâtiment : mesure de capacité de stockage dynamique d'une paroi

Prodjinonto, Vincent 15 December 2011 (has links)
L’économie d’énergie dans le bâtiment est devenue une question préoccupante d’envergure internationale. Le secteur du bâtiment en effet, est l’un des plus énergétivores avec par exemple plus de 43% du total d’énergie produite en France, mais aussi l’un des plus polluants avec environs, 23% des émissions de gaz à effet de serre. Avec l’accroissement des ménages, et la demande par conséquent d’énergie, les problèmes ci-dessus évoqués vont décupler et devenir rapidement ingérables les années à venir, si aucune mesure n’est prise. Ainsi, pour faire face à la situation, plusieurs stratégies sont mises en œuvre aux fins de réaliser l’économie d’énergie dans le bâtiment. Il y a le volet prédiction d’énergie qui oeuvre pour l’énergie juste heure après heure ; le volet recherche et élimination de ponts thermiques, afin de réduire au minimum les déperditions d’énergie représentant environ 30% de la consommation d’énergie ; et le volet conservation d’énergie dans les parois de bâtiment pour sa réutilisation future. Notre thèse s’est penchée sur les deux derniers volets en proposant différentes méthodes de CND et des traitements appropriés permettant la mise en évidence de défauts dans les structures de bâtiment. Des approches d’estimation de matrice de transfert ont été aussi abordées, pour permettre de prévoir le comportement thermique du bâtiment soumis à une sollicitation quelconque. La grande contribution de cette thèse concerne la mise au point d’une technique de mesure de capacité de stockage in-situ. Elle est importante, car il existe quantité de logiciels proposant la composition des structures d’un bâtiment pour une capacité de stockage d’énergie donnée. Mais il n’existe aucune méthode permettant de confirmer ou d’infirmer les résultats issus de calculs artificiels. Cette thèse apporte une solution à cette situation en proposant une méthode simple, sans encombrement, facile à mettre en œuvre et offrant un résultat satisfaisant. / Energy saving in buildings has become a major international issue. Indeed, the building sector is one the most energy consuming sectors, for instance in France it consumes more than 43% of the total produced energy, and also it is one of the most polluter with around 23% of the green house gas emissions. As more and more households appear, the energy demand will increase and the above mentioned problems will be ten times more sever making them unmanageable in the upcoming years if no measure is taken. Thus, to face this situation, many strategies have been setup in order to achieve some energy saving in buildings. Among these strategies we find the energy prediction part which deals with hour by hour right energy; the research and elimination part of thermal bridges which its main objective is to reduce as much as possible the energy losses representing around 30% of the energy consumption; and the energy conservation part in wall buildings for future recycling. Our thesis focuses on the last two parts by proposing different methods of CND as well as appropriate survey treatments which allow to highlight structural failure in buildings. Transfer matrix estimation approaches have been used to predict the thermal behavior for a building that is being put under any kind of stress.The main contribution of this thesis concerns the developing of an in-situ storage capacity measuring technique. This is important since there are many softwares proposing the structural composition of a building for a given amount of energy. Nevertheless, there isn’t any method available for confirming or invalidating the results coming from artificial calculations. This thesis brings a solution to this situation by proposing a simple method, with no obstacles, easy to setup and with satisfactory results.
2

Análise térmica e energética de uma edificação residencial climatizada com sistema de Fluxo de Refrigerante Variável -VRF Fernando Pozza

Pozza, Fernando January 2011 (has links)
O trabalho apresenta uma análise térmica e energética de uma edificação localizada na zona bioclimática 1, que compreende as cidades mais frias do Brasil. A análise foi desenvolvida com o auxílio do programa de simulação dinâmica de edificações EnergyPlus em que foi determinado o consumo anual de energia elétrica de toda a edificação existente, bem como o consumo do sistema HVAC (Aquecimento, Ventilação e Ar Condicionado) do tipo split com ciclo reverso. O sistema HVAC existente representa 42% do consumo total de energia elétrica da edificação sendo que o aquecimento totaliza 89% do consumo do sistema HVAC. A avaliação do conforto térmico dos ambientes climatizados da edificação foi realizada tendo como referência as zonas de conforto de inverno e de verão definidas pela ASHRAE Standard 55-2004. Os ambientes apresentaram um percentual de 7,6 % a 33% das horas de operação do sistema HVAC fora da zona de conforto térmico de inverno da ASHRAE, considerando somente a temperatura operativa. A partir dos resultados da simulação da edificação existente foram propostas modificações na envoltória e o uso de um sistema de ar condicionado com tecnologia VRF (fluxo de refrigerante variável) a fim de reduzir o consumo de energia pelo HVAC e o número de horas desconfortáveis. A utilização de vidros duplos de maior transmissividade, superfícies com cores de maior absortividade solar, lã de vidro nas paredes externas e internas duplas e placas de EPS (Poliestireno Expandido) no piso da edificação, apresentaram ótimos resultados, reduzindo o consumo total de energia elétrica em 18,2% e o consumo do sistema HVAC passou a representar apenas 29,6% do total de energia da edificação. Após o aprimoramento da edificação foram selecionadas, a partir de catálogos de fabricantes, as máquinas com tecnologia VRF que atendessem a máxima carga térmica entre os dias de projeto ou arquivo climático sob determinadas condições. Os resultados obtidos com o sistema VRF apresentaram uma redução de 32,8% sobre o consumo de energia do sistema de HVAC e de 9,3 % sobre o consumo total de energia elétrica da edificação quando comparado com um ar condicionado tradicional do tipo split. Com a melhoria na envoltória e o uso da tecnologia VRF para climatização o percentual de horas fora das zonas de conforto da ASHRAE foram menores que os 4% estabelecido pela norma, quando considerado a temperatura operativa. O sistema VRF foi simulado adaptando o módulo de simulação de serpentinas de expansão direta com compressores de velocidade variável, do EnergyPlus, para quatro faixas de capacidades distintas do compressor (60%, 80%, 100% e 120%) e para cada faixa foram inseridas as correlações de desempenho da capacidade e potência elétrica de aquecimento e refrigeração para diferentes condições de operação. Nas simulações foram considerados a perda de desempenho e o consumo elétrico para a operação de degelo com ciclo reverso para temperaturas externas inferiores a 7º C. As simulações com o sistema VRF acoplado a edificação comprovam a capacidade de economizar energia elétrica, além de apresentar o menor custo especifico da energia para aquecimento em relação aos sistemas radiantes. / This dissertation presents the thermal and energetic analysis of a building located in the bioclimatic zone 01, which comprises the coldness regions of Brazil. The analysis was developed using the software for dynamic simulation of buildings called EnergyPlus, where was determined the annual consumption of electricity throughout the existing building as well as the consumption with lighting, electrical equipments and the HVAC system. The existing HVAC system represents 42% of total consumption and the heating corresponds to 89% of the total energy consumption of the HVAC system. The evaluation of thermal comfort zones of building were conducted with reference to the comfort zones of winter and summer from the ASHRAE Standard 55-2004. The thermal zones presented a percentage in the range of 7.6% to 33% of occupation hours outside the boundaries of ASHRAE thermal comfort zone (winter) evaluating the operating temperature. Based on simulation results of the existing building, changes were proposed in the envelope and in the use of a heat pump air conditioning system with VRF technology (variable refrigerant flow) to reduce the energy consumption of the HVAC and the number of hours outside the comfort zone. The use of double layers glasses with high transmissivity and surfaces colored with high solar absorption, wool glass in the external and double internal walls and EPS sheets on the building floor, presented excellent results. The modification of the envelope decreased 18.2 % in the total consumption of electricity and the HVAC system represents only 29.6% of the total energy of the building. After the building improvement was selected from catalogs of manufacturers, machines with VRF technology that could meet the maximum heat load between design days or weather file. The results obtained with the VRF system showed a 32.8% reduction on energy consumption of HVAC system and 9.3% about the total consumption of electricity of the building compared to a traditional heat pump air conditioning system with single speed compressor. With the improvement in the envelope and the use of VRF system the percentage of hours outside the ASHRAE comfort zones were lower than the 4% target set by the standard. The VRF system was modeled from model: Multi-Speed Electric DX Air Coil, of the EnergyPlus, for four different capacities of the compressor (60, 80, 100 and 120%) and for each capacity range were included the performance correlation of heating and cooling capacity, the correlations of electrical power heating and cooling for different condition of operate and correlation of the fraction of part load operation for each machine selected. As the study was conducted to the cooler regions of Brazil, defrost was considered in the simulation with reverse cycle for operating temperatures below 7°C. The heating energy with heat pump VRF presents lower specific cost compared to radiant systems like radiant floor and radiators.
3

Análise térmica e energética de uma edificação residencial climatizada com sistema de Fluxo de Refrigerante Variável -VRF Fernando Pozza

Pozza, Fernando January 2011 (has links)
O trabalho apresenta uma análise térmica e energética de uma edificação localizada na zona bioclimática 1, que compreende as cidades mais frias do Brasil. A análise foi desenvolvida com o auxílio do programa de simulação dinâmica de edificações EnergyPlus em que foi determinado o consumo anual de energia elétrica de toda a edificação existente, bem como o consumo do sistema HVAC (Aquecimento, Ventilação e Ar Condicionado) do tipo split com ciclo reverso. O sistema HVAC existente representa 42% do consumo total de energia elétrica da edificação sendo que o aquecimento totaliza 89% do consumo do sistema HVAC. A avaliação do conforto térmico dos ambientes climatizados da edificação foi realizada tendo como referência as zonas de conforto de inverno e de verão definidas pela ASHRAE Standard 55-2004. Os ambientes apresentaram um percentual de 7,6 % a 33% das horas de operação do sistema HVAC fora da zona de conforto térmico de inverno da ASHRAE, considerando somente a temperatura operativa. A partir dos resultados da simulação da edificação existente foram propostas modificações na envoltória e o uso de um sistema de ar condicionado com tecnologia VRF (fluxo de refrigerante variável) a fim de reduzir o consumo de energia pelo HVAC e o número de horas desconfortáveis. A utilização de vidros duplos de maior transmissividade, superfícies com cores de maior absortividade solar, lã de vidro nas paredes externas e internas duplas e placas de EPS (Poliestireno Expandido) no piso da edificação, apresentaram ótimos resultados, reduzindo o consumo total de energia elétrica em 18,2% e o consumo do sistema HVAC passou a representar apenas 29,6% do total de energia da edificação. Após o aprimoramento da edificação foram selecionadas, a partir de catálogos de fabricantes, as máquinas com tecnologia VRF que atendessem a máxima carga térmica entre os dias de projeto ou arquivo climático sob determinadas condições. Os resultados obtidos com o sistema VRF apresentaram uma redução de 32,8% sobre o consumo de energia do sistema de HVAC e de 9,3 % sobre o consumo total de energia elétrica da edificação quando comparado com um ar condicionado tradicional do tipo split. Com a melhoria na envoltória e o uso da tecnologia VRF para climatização o percentual de horas fora das zonas de conforto da ASHRAE foram menores que os 4% estabelecido pela norma, quando considerado a temperatura operativa. O sistema VRF foi simulado adaptando o módulo de simulação de serpentinas de expansão direta com compressores de velocidade variável, do EnergyPlus, para quatro faixas de capacidades distintas do compressor (60%, 80%, 100% e 120%) e para cada faixa foram inseridas as correlações de desempenho da capacidade e potência elétrica de aquecimento e refrigeração para diferentes condições de operação. Nas simulações foram considerados a perda de desempenho e o consumo elétrico para a operação de degelo com ciclo reverso para temperaturas externas inferiores a 7º C. As simulações com o sistema VRF acoplado a edificação comprovam a capacidade de economizar energia elétrica, além de apresentar o menor custo especifico da energia para aquecimento em relação aos sistemas radiantes. / This dissertation presents the thermal and energetic analysis of a building located in the bioclimatic zone 01, which comprises the coldness regions of Brazil. The analysis was developed using the software for dynamic simulation of buildings called EnergyPlus, where was determined the annual consumption of electricity throughout the existing building as well as the consumption with lighting, electrical equipments and the HVAC system. The existing HVAC system represents 42% of total consumption and the heating corresponds to 89% of the total energy consumption of the HVAC system. The evaluation of thermal comfort zones of building were conducted with reference to the comfort zones of winter and summer from the ASHRAE Standard 55-2004. The thermal zones presented a percentage in the range of 7.6% to 33% of occupation hours outside the boundaries of ASHRAE thermal comfort zone (winter) evaluating the operating temperature. Based on simulation results of the existing building, changes were proposed in the envelope and in the use of a heat pump air conditioning system with VRF technology (variable refrigerant flow) to reduce the energy consumption of the HVAC and the number of hours outside the comfort zone. The use of double layers glasses with high transmissivity and surfaces colored with high solar absorption, wool glass in the external and double internal walls and EPS sheets on the building floor, presented excellent results. The modification of the envelope decreased 18.2 % in the total consumption of electricity and the HVAC system represents only 29.6% of the total energy of the building. After the building improvement was selected from catalogs of manufacturers, machines with VRF technology that could meet the maximum heat load between design days or weather file. The results obtained with the VRF system showed a 32.8% reduction on energy consumption of HVAC system and 9.3% about the total consumption of electricity of the building compared to a traditional heat pump air conditioning system with single speed compressor. With the improvement in the envelope and the use of VRF system the percentage of hours outside the ASHRAE comfort zones were lower than the 4% target set by the standard. The VRF system was modeled from model: Multi-Speed Electric DX Air Coil, of the EnergyPlus, for four different capacities of the compressor (60, 80, 100 and 120%) and for each capacity range were included the performance correlation of heating and cooling capacity, the correlations of electrical power heating and cooling for different condition of operate and correlation of the fraction of part load operation for each machine selected. As the study was conducted to the cooler regions of Brazil, defrost was considered in the simulation with reverse cycle for operating temperatures below 7°C. The heating energy with heat pump VRF presents lower specific cost compared to radiant systems like radiant floor and radiators.
4

Análise térmica e energética de uma edificação residencial climatizada com sistema de Fluxo de Refrigerante Variável -VRF Fernando Pozza

Pozza, Fernando January 2011 (has links)
O trabalho apresenta uma análise térmica e energética de uma edificação localizada na zona bioclimática 1, que compreende as cidades mais frias do Brasil. A análise foi desenvolvida com o auxílio do programa de simulação dinâmica de edificações EnergyPlus em que foi determinado o consumo anual de energia elétrica de toda a edificação existente, bem como o consumo do sistema HVAC (Aquecimento, Ventilação e Ar Condicionado) do tipo split com ciclo reverso. O sistema HVAC existente representa 42% do consumo total de energia elétrica da edificação sendo que o aquecimento totaliza 89% do consumo do sistema HVAC. A avaliação do conforto térmico dos ambientes climatizados da edificação foi realizada tendo como referência as zonas de conforto de inverno e de verão definidas pela ASHRAE Standard 55-2004. Os ambientes apresentaram um percentual de 7,6 % a 33% das horas de operação do sistema HVAC fora da zona de conforto térmico de inverno da ASHRAE, considerando somente a temperatura operativa. A partir dos resultados da simulação da edificação existente foram propostas modificações na envoltória e o uso de um sistema de ar condicionado com tecnologia VRF (fluxo de refrigerante variável) a fim de reduzir o consumo de energia pelo HVAC e o número de horas desconfortáveis. A utilização de vidros duplos de maior transmissividade, superfícies com cores de maior absortividade solar, lã de vidro nas paredes externas e internas duplas e placas de EPS (Poliestireno Expandido) no piso da edificação, apresentaram ótimos resultados, reduzindo o consumo total de energia elétrica em 18,2% e o consumo do sistema HVAC passou a representar apenas 29,6% do total de energia da edificação. Após o aprimoramento da edificação foram selecionadas, a partir de catálogos de fabricantes, as máquinas com tecnologia VRF que atendessem a máxima carga térmica entre os dias de projeto ou arquivo climático sob determinadas condições. Os resultados obtidos com o sistema VRF apresentaram uma redução de 32,8% sobre o consumo de energia do sistema de HVAC e de 9,3 % sobre o consumo total de energia elétrica da edificação quando comparado com um ar condicionado tradicional do tipo split. Com a melhoria na envoltória e o uso da tecnologia VRF para climatização o percentual de horas fora das zonas de conforto da ASHRAE foram menores que os 4% estabelecido pela norma, quando considerado a temperatura operativa. O sistema VRF foi simulado adaptando o módulo de simulação de serpentinas de expansão direta com compressores de velocidade variável, do EnergyPlus, para quatro faixas de capacidades distintas do compressor (60%, 80%, 100% e 120%) e para cada faixa foram inseridas as correlações de desempenho da capacidade e potência elétrica de aquecimento e refrigeração para diferentes condições de operação. Nas simulações foram considerados a perda de desempenho e o consumo elétrico para a operação de degelo com ciclo reverso para temperaturas externas inferiores a 7º C. As simulações com o sistema VRF acoplado a edificação comprovam a capacidade de economizar energia elétrica, além de apresentar o menor custo especifico da energia para aquecimento em relação aos sistemas radiantes. / This dissertation presents the thermal and energetic analysis of a building located in the bioclimatic zone 01, which comprises the coldness regions of Brazil. The analysis was developed using the software for dynamic simulation of buildings called EnergyPlus, where was determined the annual consumption of electricity throughout the existing building as well as the consumption with lighting, electrical equipments and the HVAC system. The existing HVAC system represents 42% of total consumption and the heating corresponds to 89% of the total energy consumption of the HVAC system. The evaluation of thermal comfort zones of building were conducted with reference to the comfort zones of winter and summer from the ASHRAE Standard 55-2004. The thermal zones presented a percentage in the range of 7.6% to 33% of occupation hours outside the boundaries of ASHRAE thermal comfort zone (winter) evaluating the operating temperature. Based on simulation results of the existing building, changes were proposed in the envelope and in the use of a heat pump air conditioning system with VRF technology (variable refrigerant flow) to reduce the energy consumption of the HVAC and the number of hours outside the comfort zone. The use of double layers glasses with high transmissivity and surfaces colored with high solar absorption, wool glass in the external and double internal walls and EPS sheets on the building floor, presented excellent results. The modification of the envelope decreased 18.2 % in the total consumption of electricity and the HVAC system represents only 29.6% of the total energy of the building. After the building improvement was selected from catalogs of manufacturers, machines with VRF technology that could meet the maximum heat load between design days or weather file. The results obtained with the VRF system showed a 32.8% reduction on energy consumption of HVAC system and 9.3% about the total consumption of electricity of the building compared to a traditional heat pump air conditioning system with single speed compressor. With the improvement in the envelope and the use of VRF system the percentage of hours outside the ASHRAE comfort zones were lower than the 4% target set by the standard. The VRF system was modeled from model: Multi-Speed Electric DX Air Coil, of the EnergyPlus, for four different capacities of the compressor (60, 80, 100 and 120%) and for each capacity range were included the performance correlation of heating and cooling capacity, the correlations of electrical power heating and cooling for different condition of operate and correlation of the fraction of part load operation for each machine selected. As the study was conducted to the cooler regions of Brazil, defrost was considered in the simulation with reverse cycle for operating temperatures below 7°C. The heating energy with heat pump VRF presents lower specific cost compared to radiant systems like radiant floor and radiators.
5

Náhrada expanzního ventilu kapilární trubicí / Expansion valve replacing with the capillary tube

Devečka, Viktor January 2016 (has links)
V súčasnosti sa kladie veľký dôraz na znižovanie produkcie emisií, čistotu a kvalitu životného prostredia. Tieto trendy sa týkajú všetkých odvetví, tak isto aj stavebného priemyslu a vykurovania budov. Doposiaľ bolo najrozšírenejším typom vykurovania spaľovanie fosílnych palív. Do popredia sa však dostávajú tepelné čerpadlá a začínajú zaberať výrazný podiel trhu. Kvôli dopytu po tepelných čerpadlách vzrastá počet výrobcov a konkurencia. Cieľom výrobcov je zvyšovanie účinnosti tepelných čerpadiel a zároveň znižovanie výrobných nákladov na dosiahnutie lepšej pozície na trhu. Predložená práca sa zaoberá procesmi prebiehajúcimi v chladivovom okruhu tepelného čerpadla. Skúma správanie chladiva počas kondenzácie a možnosti zvýšenia účinnosti tepelného čerpadla. Zvýšenie účinnosti je dosiahnuté podchladením chladiva počas kondenzácie na zvýšenie tepelných ziskov. To je dosiahnuté zaradením druhého elektronického expanzného ventilu za kondenzátorom. Táto technológia je však finančne náročná. Práca sa zaoberá výpočtom kapiláry na základe praktických meraní, ktorá bude zadržiavať chladivo v kondenzátore a bude plniť podobnú úlohu ako expanzný ventil. Následne sú porovnané výsledky jednotlivých meraní. Výsledky sú porovnané voči jednoduchému systému, kde nedochádza k podchladeniu chladiva. V závere práce je analýza výsledkov jednotlivých systémov.
6

Amélioration et intégration d'une méthode d'affichage des performances en temps réel d'une pompe à chaleur / Improvement and integration of the in-situ heat pump performance assessment method

Niznik, Maria 10 July 2017 (has links)
Actuellement, la plupart des fabricants de pompes à chaleur (PAC) fournissent les valeurs de coefficients de performances (COP) obtenus en laboratoire en conditions contrôlées et standardisées. Une méthode prometteuse, appelée méthode de mesure des performances dans la suite, d’évaluation des performances de PAC in situ, basée sur le bilan énergétique du compresseur, a été présentée par Tran et al. (2013). Cette méthode détermine le débit de fluide frigorigène et est compatible avec différents types de PAC, notamment air-air, et des cycles frigorifiques plus complexes.Tran et al. (2013) ont déterminé que l’incertitude sur l’évaluation de pertes thermiques du compresseur contribue à hauteur de 40% sur l’erreur d’estimation de la puissance thermique. L’objectif de cette thèse est d’établir une méthode simplifiée quant à l’instrumentation pour mesurer les pertes thermiques in situ. Pour cela, deux modèles numériques détaillés sont développés afin d’examiner la distribution de température sur l’enveloppe de deux types de compresseurs, scroll et rotary. Les mesures expérimentales fournies par un fabricant de compresseurs, Mitsubishi Heavy Industries (MHI), sont utilisées pour calibrer et valider les modèles numériques. Ces derniers permettent de définir deux protocoles de mesures différents pour les deux compresseurs. Ensuite, le protocole établi pour le compresseur rotary est intégré dans la méthode de mesures des performances. Les puissances thermiques calculées sont comparées avec des valeurs de référence, obtenues à partir d’un prototype en banc d’essai à EDF Lab Les Renardières. / Currently, most heat pump(HP) manufacturers provide coefficient of performance (COP) values obtained in laboratories under standardized controlled operating conditions. These COP values are not necessarily representative of those obtained on-field. A promising method, referred to as the performance assessment method, that measures heat pump performances in-situ based on compressor energy balance, was presented by Tran et al. (2013). The method determines refrigerant mass flow rate and has the capability of measuring performances of various HP types, such as air-to-air, as well as more complex refrigeration cycles. The method abstains from intrusive measurements, and is, therefore, perfectly suitable for in-situ measurements.As shown in the work of Tran et al. (2013), compressor heat losses account for 40% in the final uncertainty of performance values obtained with the performance assessment method. The objective of this thesis is to establish a rather simplified measurement method, in terms of instrumentation, that is used to determine compressor heat losses in-situ. For this purpose two detailed numerical models for assessing the temperature fields of the scroll and rotary compressor shells were developed. Experimental measurements obtained with the help of compressor manufacturer, Mitsubishi Heavy Industries (MHI), are used to validate and calibrate the numerical models. The developed numerical models allow to define two different measurement protocols for both compressors. Established compressor heat loss protocol for rotary compressor is then integrated in the performance assessment method and the obtained heating capacities are compared with reference measurements in an experimental test bench in EDF Lab Les Renardières.

Page generated in 0.0776 seconds