• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 978
  • 16
  • 15
  • 15
  • 15
  • 9
  • 7
  • 7
  • 6
  • 4
  • 3
  • 3
  • 1
  • 1
  • 1
  • Tagged with
  • 1002
  • 654
  • 321
  • 225
  • 114
  • 103
  • 95
  • 82
  • 80
  • 79
  • 74
  • 71
  • 70
  • 66
  • 61
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
561

Influência do tempo de aplicação do bicarbonato de sódio a 10% na adesão ao esmalte bovino clareado: estudo in vitro / Effect of the application time of 10% sodium bicarbonate on bleached enamel: an in vitro study

Marina Studart Alencar Borges 08 December 2016 (has links)
Este estudo in vitro avaliou a influência do tempo de aplicação do bicarbonato de sódio a 10% na qualidade da união de um sistema adesivo universal unido ao esmalte bovino clareado por meio de testes de resistência de união (microtração imediata e após 6 meses) e grau de conversão na interface adesiva (espectroscopia micro-Raman). Cento e dez blocos de esmalte bovino (4x4 mm) foram planificados e distribuídos aleatoriamente em 5 grupos: C: controle, sem clareamento; B: clareamento com peróxido de hidrogênio 35% (HP); BS3: clareamento com HP seguido de tratamento com a solução de bicarbonato de sódio 10% (BS) por 3 min; BS5: clareamento com HP seguido de tratamento com BS por 5 min; BS10: clareamento com HP seguido de tratamento com BS por 10 min. O HP foi aplicado duas vezes (20 minutos cada, com exceção do grupo C) e em seguida as restaurações adesivas foram realizadas. Após 24 horas, 20 espécimes de cada grupo foram seccionados em palitos (1x1 mm) e submetidos ao teste de resistência de união (imediato e após 6 meses) em máquina de ensaios universal com velocidade de 0,5 mm/min (n=10). Os dados foram analisados por ANOVA a dois critérios (p <0,05). As médias das análises imediata e após 6 meses foram: C: 26,77 / 25,32; B: 26,42 / 26,42; BS3: 23,95 / 22,98; BS5: 23,65 / 26,64; BS10: 23,42 / 29,30. Nenhum dos fatores testados apresentou significância: tratamento (p=0,349) e tempo (p=0,234), não havendo interação entre estes (p=0,198). Falhas adesivas foram predominantes nos dois períodos de avaliação. Para a análise do grau de conversão, após 24 horas da restauração, 2 espécimes de cada grupo foram seccionados em fatias de 1mm, sendo apenas 3 fatias selecionadas. Os seguintes parâmetros foram utilizados: excitação dos espécimes com laser de argônio operando a 538 nm, espectro obtido a uma resolução ~4cm-1, sob uma região de espectro entre 1580-1660cm-1, verificando a altura dos picos 1608cm-1 e 1637cm-1. Os dados foram analisados por ANOVA a um critério (p <0,05) e as médias do grau de conversão foram: C: 71,10%; B: 72,11%; BS3: 73,98%; BS5: 69,25%; BS10: 70,56%. O fator de estudo tratamento não apresentou significância estatística (p=0,808). A adesão no esmalte clareado parece não ter sido afetada negativamente quando restaurações adesivas foram feitas imediatamente após o clareamento, independente da aplicação ou não da substância antioxidante. Mais estudos que avaliem a adesão em esmalte clareado, principalmente no que diz respeito ao grau de conversão e aos diferentes tipos de sistemas adesivos universais se fazem necessários para fins comparativos e para que possamos indicar seguramente as restaurações imediatas (quando necessárias) na prática clínica. / The present in vitro study evaluated the influence of the application time of 10% sodium bicarbonate in the adhesion quality of a universal adhesive system bonded to bleached enamel through microtensile bond strength testing (immediate and after 6 months) and the degree conversion (micro-Raman spectroscopy). One hundred and ten bovine enamel blocks (4x4mm) were flattened and randomly allocated into 5 groups: C: control, without bleaching; B: bleached with 35% hydrogen peroxide (HP); BS3: bleached and treated with 10% sodium bicarbonate solution (BS) for 3 min; BS5: bleached and treated with BS for 5 min; BS10: bleached and treated with BS for 10 min. HP was applied twice (20 minutes each, except in group C) and the adhesive restorations were performed. After 24 hours, 20 specimens from each group were sectioned into sticks (1x1 mm) and submitted to microtensile bond strength testing (immediately and after 6 months) in a universal testing machine with a crosshead speed of 0.5 mm/min (n = 10). Data was analyzed by two-way ANOVA (p <0.05). The means of the immediate and 6 months analysis were: C 26.77 / 25.32; B: 26.42 / 26.42; BS3: 23.95 / 22.98; BS5: 23.65 / 26.64; BS10: 23.42 / 29.30. None of the tested factors showed significance: treatment (p = 0.349) and time (p = 0.234), with no interaction between them (p = 0.198). Adhesive failures were predominant in both evaluation periods. For the degree of conversion analysis, 2 specimens of each group were sectioned into 1 mm slices after 24 hours of the restorative procedure, and 3 slices were selected. The following parameters were used: excitation of specimens with argon laser operating at 538 nm, spectrum obtained at a resolution of ~4cm-1, under a spectrum region between 1580-1660cm-1, evaluating the height of the peaks at 1608cm-1 and 1637cm-1. Data was analyzed by one-way ANOVA (p <0.05). The means of degree of conversion were: C: 71.10%; B: 72.11%; BS3: 73.98%; BS5: 69.25%; BS10: 70.56%. The study factor \"treatment\" was not statistically significant (p = 0.808). The results of bonding to bleached enamel was not negatively affected when adhesive restorations were made immediately after bleaching, regardless of the application of the antioxidant substance. Further studies to evaluate the adhesion on bleached enamel, mainly with regard to the degree of conversion and different types of universal adhesive systems are needed for comparative purposes. Only after this, the immediate restoration (if necessary) in clinical practice can be safely and indicated.
562

Avaliação in vivo da efetividade e do pH  de géis clareadores no clareamento em consultório em 12 meses de acompanhamento / In vivo evaluation of the effectiveness and pH of bleaching gels for in office whitening- 12 months follow-up

Ana Carolina Trentino Delafiori 10 December 2015 (has links)
O objetivo deste estudo in vivo, internacional, randomizado e duplo cedo foi avaliar comparativamente a efetividade e o pH de diferentes géis clareadores na técnica de clareamento em consultório, com e sem o emprego de fonte de luz híbrida em função do grau de alteração de cor, sensibilidade e manutenção do tratamento ao longo de 12 meses de acompanhamento. Foram selecionados 48 voluntários de acordo com os critérios de inclusão e exclusão. Os pacientes foram divididos, de forma randomizada, em 4 grupos de 12 participantes cada, onde: Grupo EXP10 5 aplicações do gel de peróxido de hidrogênio a 10% (Gel Experimental DMC Equipamentos) e ativação de luz híbrida de LED (violeta)/Laser (Experimental DMC Equipamentos) com 7&#x2032; e 30&#x2033; por aplicação, com tempo total de 37&#x2032;30; Grupo LP15 5 aplicações do gel de peróxido de hidrogênio 15% (Lase Peroxide Lite DMC Equipamentos) seguindo mesmo protocolo do grupo EXP10; Grupo TB35LH 3 aplicações do gel de peróxido de hidrogênio a 35% (Total Blanc Office - DFL) e ativação de luz híbrida de LED (azul)/Laser (Whitening Lase II DMC Equipamentos) de 7&#x2032; e 30&#x2033; por aplicação, com tempo total de 22&#x2032;30&#x2033;; Grupo TB35 3 aplicações do gel de peróxido de hidrogênio a 35% (Total Blanc Office - DFL) sem ativação com fonte de luz, totalizando 45&#x2033;. A determinação dos valores de pH foi realizada com o peagômetro digital (Sentron Model 1001, Sentron) nos tempos inicial e após o término do protocolo clareador. A aferição da cor foi feita com espectofotômetro VITA Easyshade antes do clareamento, após 24 horas, 1 semana, 1, 6 e 12 meses. A sensibilidade dentária e grau de satisfação dos pacientes foram avaliados por meio do questionário VAS e IPS antes, imediatamente após o clareamento, 24 horas e uma semana após. Os resultados da alteração do pH receberam tratamento estatístico pela ANOVA e teste de Bonferroni a 0,05%. Os resultados indicaram que o pH aumentou do momento inicial para o final para todos os protocolos. Não houve diferenças significativas entre os protocolos TB35 e TB35LH em nenhum dos momentos, e o pH médio do grupo EXP10 foi maior em comparação aos outros três grupos nos dois momentos avaliados. Os resultados do &#x394;E receberam tratamento estatístico pela ANOVA e teste de Bonferroni a 0,05%. Os resultados indicaram que não houve diferença significativa entre os grupos LP15, TB35 e TB35LH. O &#x394;E médio observado após 24 horas foi estatisticamente maior que para os outros tempos (inicial, 1 semana, 1 mês, 6 e 12 meses). Para análise da sensibilidade foi construído um modelo linear misto e atribuídos postos (ranks) aos valores de &#x394; e teste de Bonferroni a 0,05% para comparações pareadas. Não houve diferença nos valores da sensibilidade imediatamente e 24 horas após o tratamento, com relação ao momento inicial. Houve diferença significativa entre &#x394;1 e &#x394;3 indicando que a sensação de dor após uma semana do tratamento foi menor do que as observadas nos instantes imediato e após 24 horas. Para os resultados de satisfação foi construído um modelo linear misto e atribuídos postos (ranks) e o Método de Bonferroni (0,05%) foi utilizado para as comparações pareadas do efeito de tempo. Os resultados indicam queda nos níveis de satisfação entre os períodos imediato e um ano e entre os períodos 24 horas e um ano. Todos os géis clareadores apresentaram mínima variação do pH nos tempos avaliados, entretanto houve um aumento do pH da primeira para a última aplicação em todos os grupos estudados e o grupo EXP10 apresentou os maiores valores de pH seguido do LP15, TB35LH e TB35 apresentaram os valores mais baixos de pH. Os grupos LP15, TB35 e TB35LH apresentaram menor variação da cor ao longo de 12 meses de acompanhamento. O efeito do protocolo clareador não influenciou a sensibilidade dos pacientes e após uma semana a sensibilidade retornaram aos níveis normais. O nível de satisfação dos pacientes foi significativo em relação ao tempo e não aos protocolos clareadores, os pacientes do grupo TB35 mostraram-se mais insatisfeitos ao longo da pesquisa. / The aim of the present in vivo study, international, randomized and double early was to comparatively evaluate the effectiveness and pH of different bleaching agents for in office bleaching techniques, with and without the use of a hybrid light source depending on the degree of color change, sensitivity and maintenance treatment over a 12-month follow-up. Selected were 48 volunteers according to the inclusion and exclusion criteria. The patients were randomly divided into 4 groups of 12 participants each, where: EXP Group10- 5 applications of 10% hydrogen peroxide gel (Experimental Gel - Equipment DMC) and activation of hybrid LED light (violet) / Laser (Experimental - Equipment DMC) with 7 &#x2033;and 30&#x2033; per application, with a total time of 37&#x2032;30; LP15 Group- 5 applications of 15% hydrogen peroxide gel (Lase Peroxide Lite - Equipment DMC) following the same protocol of the EXP10 Group; TB35LH Group- 3 applications of 35% hydrogen peroxide gel (of Blanc Office - DFL) and activation of hybrid LED light (blue) / Laser (Whitening Lase II - DMC Equipment) 7 &#x2033;and 30&#x2033; per application, with a total time of 22&#x2032;30; TB35 Group - 3 applications of 35% hydrogen peroxide gel (of Blanc Office - DFL) without light activation, totaling 45 &#x2033;. The determination of pH was carried out with a digital pH meter (Sentron Model 1001, Sentron) in the initial times and after the bleaching protocol. The color measurement was made with a VITA Easyshade spectrophotometer before the treatment, after 24 hours, 1 week, 1, 6 and 12 months. Tooth sensitivity and degree of patient satisfaction were assessed by the VAS IPS questionnaire before, immediately after bleaching, 24 hours and one week after. The pH change results were statistically processed by the ANOVA and Bonferroni tests at 0.05%. The results indicated that the pH increased from baseline to the end for all protocols. There were no significant differences between the TB35 and TB35LH protocols in any of the times, and the average pH of the EXP10 group was higher compared to the other three groups in the two periods evaluated. The results of the &#x394;E received statistical analysis by ANOVA and Bonferroni testing at 0.05%. The results indicated that there was no significant difference between the LP15, TB35 and TB35LH Groups. The average &#x394;E observed after 24 hours was statistically greater than for the other times (initial, 1 week, 1 month, 6 months and 12 months). For the sensitivity analysis, a mixed linear model was constructed and assigned points (ranks) for &#x394; values and the Bonferroni test at 0.05% was used for paired comparisons. There was no difference in sensitivity values immediately and 24 hours after treatment with the initial time. There was a significant difference between &#x394;1 and &#x394;3 indicating that the sensation of pain after one week of treatment was lower than those observed in the immediate times and after 24 hours. For the results of satisfaction, a mixed linear model was constructed and assigned points (ranks) and the Bonferroni method (0.05%) was used for paired comparisons of time effects. The results indicate a reduction in the levels of satisfaction between the immediate and one year periods and periods between 24 hours and one year. All bleaching gels showed minimal pH variation in the evaluated times, however, there was an increase in pH from the first to the last application in all groups and the EXP Group showed the highest pH followed by the LP15, TB35LH and TB35 Groups which presented lower pH values. The LP15, TB35 and TB35LH Groups showed less color variation over a 12 month follow-up. The effect of the bleaching protocol did not affect the sensitivity of patients and after a week, and the sensitivity returned to normal levels. The level of patient satisfaction was significant in relation to the time and not the bleaching protocols. The patients in the TB35 Group were more dissatisfied during the research.
563

Soluções sólidas intersticiais na liga NB-TI46 / Interstitial solid solution in Nb-Ti 46 alloy

Odila Florêncio 18 September 1986 (has links)
Não disponível / Not available
564

Produção de hidrogênio em refinarias de petróleo: avaliação exergética e custo de produção. / Exergy and thermoeconomic evaluation of a petroleum refinery hydrogem production unit.

Flávio Eduardo da Cruz 19 April 2010 (has links)
O hidrogênio molecular (H2) é um gás muito útil nas indústrias químicas e petroquímicas por conta de sua facilidade de reação com outros elementos químicos. Nas refinarias é o principal insumo no processo de remoção do enxofre de diversos combustíveis como a gasolina e óleo diesel, tendo sua demanda aumentada por conta de novas legislações ambientalmente mais restritivas. O hidrogênio é normalmente encontrado na natureza associado a outros elementos químicos, como a água ou os hidrocarbonetos, sendo necessária a aplicação de processos específicos para sua obtenção. Considerada a rota mais econômica para a produção de hidrogênio, o processo de reforma a vapor do gás natural é avaliado pela aplicação da metodologia de análise exergética e termoeconômica, a fim de determinar a eficiência exergética do processo e o custo de produção do hidrogênio. Este custo de produção é muito sensível ao custo do gás natural, fato que pode prejudicar a competitividade desta rota de produção e, consequentemente, abrir a possibilidade de investir na produção de hidrogênio através de tecnologias alternativas. A unidade de geração de hidrogênio estudada está presente em uma das refinarias da Petrobras e sua produção destina-se à remoção do enxofre presente no óleo diesel. Uma planta síntese do processo foi elaborada e as eficiências exergéticas dos componentes foram determinadas. Em seguida, foi realizada uma análise econômica para determinar o custo de construção, operação e manutenção da planta. Com base nos resultados obtidos, aplicou-se a metodologia de análise termoeconômica para determinar o custo de produção de hidrogênio. Dois tipos de custo foram determinados, o custo atual (ou atualizado) de produção, que indica o custo corrente (2010) do produto, e o custo nivelado, que leva em consideração a produção total prevista ao longo vida útil da planta. Para um custo de gás natural igual a 9,11 US$/GJ, o custo de produção do hidrogênio em base exergética foi igual a 17,36 US$/GJ (2.093,13 US$/t) para o valor atual e 25,35 US$/GJ (3.056,97 US$/t) para o valor nivelado. Por fim, estes valores são comparados com outros custos de produção de hidrogênio presentes na literatura. / Pure hydrogen (H2) is an useful gas in chemical and petrochemical industries because it reacts easily with several other elements. On refineries, hydrogen is used to sequestrate sulphur from diesel and gasoline. Emission restrictions regard to fossil fuels are rising the world hydrogen demands. In spite of its abundance, hydrogen is normally found associated with other chemical species like water or hidrocarbons like methane or butane. Some especific processes are required to obtain pure hydrogen. Considered the most economic production route, the natural gas reforming process is analyzed by exergetic and thermoeconomic methods in order to determine the efficiencies and the hydrogen production cost. The hydrogen production cost is very sensitive to the cost of natural gas, which has suffered constant increases due to rising demand. This fact opens the possibility of using technologies that were previously considered economically unviable. The hydrogen unit studied was constructed in one of the Petrobras refineries, and the hydrogen produced is for the removal of sulfur in diesel oil. Based on project documents exergetic efficiencies of each component were determined. After that, an economic analysis was conducted in order to determine the construction, operation and maintenance costs of the whole plant. Two types of cost were determined, the actual cost production, which indicates the current cost product (2010), and the levelized cost, which takes into account the total production over life of the plant. Considering a natural gas cost equal to 9.11 US$/GJ, it was obtained an actual hydrogen production cost of 17.36 US$/GJ (2,093.13 US$/t) and a levelized cost of 25.35 US$/GJ (3,056.97 $/t). These values were compared with some hydrogen production costs presents on scientific papers and related references.
565

Fotodegradação de polímeros solúveis em água e moléculas modelo via processos oxidativos avançados / Photodegradation of water soluble polymers and model molecules via advanced oxidative processes

Laís Calixto Santos 13 October 2008 (has links)
Neste trabalho foi investigado o mecanismo de fotodegradação de polímeros e também a ação de agentes estabilizantes. Foi investigada a degradação oxidativa de polímeros solúveis em água como poli(vinilpirrolidona), PVP; poli(acrilamida), PAM e poli(etilenoglicol), PEG na presença de peróxido de hidrogênio, reagente de Fenton e sal de ferro. O PVP apresentou a menor fotoestabilidade enquanto a PAM apresentou a maior fotoestabilidade. O sal de ferro não promoveu a degradação. As soluções de PEG foram fotooxidadas com os sistemas UV/H2O2, Fenton e foto-Fenton e as amostras foram analisadas por GPC e HPLC. A análise por GPC das soluções de PEG mostrou que em todas as condições oxidativas usadas, a fotooxidação leva a uma queda acentuada da Mw, caracterizando um mecanismo de quebra de cadeia aleatório. Para os três sistemas usados, a polidispersidade aumenta após a degradação, confirmando o mecanismo de quebra aleatória de cadeia. As medidas de GPC também mostraram que a velocidade de degradação é muito maior com o sistema foto-Fenton (kd = 1,010-4 mol.g-1.min-1), seguida pelo sistema UV/H2O2 (kd = 3,610-5 mol.g-1.min-1). O uso do reagente de Fenton apresentou a menor velocidade de degradação (kd = 1,110-6 mol.g-1.min-1). Os produtos de degradação do PEG, nos três sistemas analisados, foram analisados por HPLC, sendo identificados produtos de menor peso molecular, entre eles, EG, 2EG, 3EG, 4EG, e os ácidos glicólico e fórmico. O mecanismo envolve um processo consecutivo em que os etilenoglicóis de maior peso molecular dão origem aos de menor peso molecular. Etilenoglicóis de cadeia curta foram usados com sucesso como moléculas modelo para prever o mecanismo de fotodegradação do PEG. Fenóis primários combinados com antioxidantes secundários contendo fósforo são os sistemas estabilizantes mais efetivos, amplamente usados na estabilização do processamento e na aplicação de olefinas a longo prazo. O mecanismo de reação de hidrólise dos antioxidantes fosfito, escolhidos para diferenciar na estrutura química e no conteúdo de fósforo, é investigado através da espectrometria de massas. Substituintes diferentes em torno do átomo de fósforo mostram um efeito significativo na estabilidade dos fosfitos com substituintes fenol, produzindo estruturas hidroliticamente estáveis. / The aim of this work was to investigate polymer photodegradation mechanisms and stabilizing agents. The course of photooxidative degradation of some water soluble polymers (poly(vinylpyrrolidone), PVP; poly(acrylamide), PAM and poly(ethylene glycol), PEG) in the presence of hydrogen peroxide, Fenton reagent and iron salt has been investigated. PVP showed the lowest photostability while PAM had the greatest photostability. Iron salt was not efficient promoting degradation. PEG has been photooxidized in Fenton, photo-Fenton and UV/H2O2 systems. Samples were analysed using GPC and HPLC. GPC analysis of PEG solutions showed that in all oxidizing conditions used, the photooxidation of PEG aqueous solutions leads to an abrupt decrease of Mw, which means that the degradation of PEG implies a random chain scission mechanism. Polydispersity increases after degradation in all the systems used, confirming a random chain scission mechanism. GPC analysis also showed that the rate of degradation is much higher for the photo-Fenton system (kd = 1,010-4 mol.g-1.min-1), followed by UV/H2O2 system (kd = 3,610-5 mol.g-1.min-1 ). Fenton reagent has the lowest degradation rate (kd = 1,110-6 mol.g-1.min-1). The degradation products of PEG in all oxidizing systems, were analyzed by HPLC and lower molecular weight products were detected, i.e., EG, 2EG, 3EG, 4EG, glycolic and formic acids. The mechanism involved a consecutive process, were the larger ethyleneglycols gave rise, successively, to smaller ones. This suggested that the mechanism involved successive scissions of the polymer chain. Ethyleneglycols were successfully used as model molecules to predict PEGs photodegradation mechanism. Primary hindered phenols in combination with phosphorous-based secondary antioxidants are one of the most effective stabilizing systems, widely used in the processing stabilization and long-term application of polyolefins. The hydrolysis reaction mechanism of phosphite antioxidants, chosen to differ in chemical structure and phosphorus content, is investigated by mass spectrometric means. The analytes under investigation are exposed to accelerated humid ageing conditions and their hydrolytic pathway and stability is investigated. Different substituents around the phosphorus atom are shown to have a significant effect on the stability of the phosphites with phenol substituent producing very hydrolytically stable structures.
566

\"Transferência de carga e ligação de hidrogênio intramolecular em derivados de 9-aminoacridina\" / \"Intramolecular charge and hydrogen bon transfer in 9-aminoacridine derivatives\"

Robson Valentim Pereira 25 August 2006 (has links)
Neste trabalho, o corante 9-aminoacridina foi derivatizado com compostos vinílicos que possuem grupos retiradores de elétrons. A incorporação destes leva à mudanças nas propriedades fotofísicas dos derivados, tais como deslocamentos para regiões de menor energia nos espectros de absorção e emissão, sugerindo a presença de transferência de carga intramolecular (ICT). Os estudos de fluorescência resolvida no tempo confirmam este processo para os derivados. Este estado ICT possui um tempo formação na faixa de 150 – 300 ps e um tempo de vida entre 1 – 3 ns, que depende do solvente. Os derivados que apresentam pelo menos um grupo carbonila como retirador de elétron, possuem um tempo de vida longo na faixa de 8 –10 ns, atribuído à emissão do enol, formado a partir da conjugação estendida por ponte de hidrogênio. A polimerização destes derivados com o ácido metacrílico promoveram mudanças em suas propriedades fotofísicas estacionárias e resolvidas no tempo devido à quebra da conjugação &#61552; estendida. Este fato é ilustrado pelos espectros de absorção e emissão que mostram bandas estruturadas, deslocadas para a região de maior energia e um decaimento monoexponencial, semelhante ao observado com 9-aminoacridina. Anisotropia de fluorescência resolvida no tempo mostra que nos copolímeros o tempo de relaxação rotacional do corante é muito sensível à mudança conformacional do poli (ácido metacrílico) com o pH, possibilitando assim o estudo da dinâmica deste polímero em solução aquosa. / In this work, the dye 9-aminoacridine was derivatized with vinylic compounds containing electron withdrawing groups. The incorporation of these groups leads to changes in the photophysical properties of the dye, such a red shift in the absorption and emission spectra, suggesting the presence of intramolecular charge transfer (ICT) effect. Time-resolved studies have confirmed such process in all derivatives. This ICT state has a risetime in the range 150 – 300 ps and a fluorescence lifetime between 1 – 3 ns, that depends of the solvent. The derivatives with at least one carbonyl group as electron withdrawing, have an additional lifetime in the range of 8 –10 ns, attributed to the enol emission formed by the extended conjugation. The polimerization of these derivatives with methacrylic acid induces changes in the stationary and time-resolved properties of the dye due to the breaking of the extended &#61552;&#61472;conjugation. This fact is illustrated by the absorption and emission spectra that show structured bands with a blue shift, and a monoexponencial decay, similar to the behavior of 9- aminoacridine. Time-resolved fluorescence anisotropy of the bound dye shows that the copolymers have a segment relaxation of the chain is very sensitive to the change in the conformational shape of poly (methacrylic acid) with pH, and such a process is well indicated by following the rotational relaxation of the dye.
567

Investigação do processo de metanação de CO em ânodos de células a combustível PEMFC / Investigation of the CO methanation process in PEMFC fuel cell anodes

Guilherme Gonçalves de Aquino Saglietti 09 May 2013 (has links)
Neste trabalho foi estudada a reação de metanação do CO em catalisador de Ru/C e sua aplicação em purificação de hidrogênio para utilização em célula a combustível. Tendo como meta a otimização da produção de metano em baixas temperaturas foram preparados materiais de RuxPd(1-x)/C, que também foram tratados termicamente em atmosfera úmida e redutora. Ao final do estudo com CO, também foi investigado o efeito da presença de CO2 no fluxo de hidrogênio, tal qual num sistema real utilizando-se gás de síntese. Os dados obtidos por espectroscopia de energia dispersiva de Raio-X (EDX) mostraram uma boa correspondência entre as composições teóricas e as obtidas experimentalmente dos catalisadores preparados neste trabalho. Analisando-se os difratogramas de Raio-X (DRX) foi possível observar a presença de fases metálicas principalmente de Ru, observando-se também o aumento da cristalinidade do material, promovido pelo tratamento térmico. Além disso, os tamanhos médios de cristalito (TMC) dos materiais foram obtidos com a equação de Scherrer e situaram-se em torno de 2,5 nm. As micrografias de TEM confirmaram o tamanho reduzido das partículas, mas apontaram para uma baixa dispersão dos materiais sobre o suporte, principalmente no caso do Ru/C. Com as medidas de XPS foram identificadas espécies de Ru metálico, Ru(IV), Ru(VII), RuOxHy e Ru.xH2O. O tratamento térmico somente afetou a população de espécies do material Ru/C, que passou a apresentar maior percentual de Ru metálico, em detrimento aos óxidos. Os catalisadores Ru/C e Ru7Pd3/C antes e após o tratamento térmico foram acomodados em filtro de linha gasosa (reator de leito fixo), sendo possível concluir que o tratamento térmico somente promoveu melhora no desempenho metanador para o catalisador Ru/C. Quando utilizados em camada difusora anódica este efeito foi ainda mais pronunciado, sendo observada a produção de CH4 em regime estacionário em Ru/C tratado termicamente quando a temperatura de metanação foi 85 &deg;C. O material mais eficiente foi o de Ru/C após o tratamento térmico, sendo capaz inclusive de hidrogenar seletivamente o CO na presença de CO2. A melhora no desempenho da célula que utilizou este material foi mais notável a 105 &deg;C, possibilitando a operação com 33 mV de sobrepotencial a 1 A.cm-2 quando alimentada com H2 contendo 75 ppm de CO. / In this work the CO methanation reaction over Ru/C catalyst and its practical applications for use as hydrogen purifier for low temperature fuel cell anodes were studied. Aiming at optimizing the low temperature methane production, two main procedures were proposed: The use of RuxPd(1-x)/C materials and its corresponding thermal treatment of the Ru/C catalyst under wet and reductive atmosphere. The effect of the presence of CO2 was then investigated under the same conditions as for CO in order to establish the catalysts selectivity for the CO methanation in the presence of CO2, as in a real system using syngas. EDX data showed a good agreement between the expected compositions and that actually obtained for catalysts prepared in this work. DRX spectra have indicated the presence of metallic phases, particularly of Ru, and the increase of the material crystallinity, promoted by the thermal treatment. Furthermore, the materials mean crystallite sizes were obtained by the use of the Scherer equation and they resulted around 2,5 nm for all samples. TEM micrographs confirmed the small particle size but also showed a poor material dispersion of the metals over the carbon support, especially in the case of Ru/C. XPS measurements have evidenced the presence of ruthenium species such as Ru(IV), Ru(VII), RuOxHy and Ru.xH2O in the prepared ruthenium material. The thermal treatment only affected the Ru species population, showing more metallic ruthenium and less oxides. The Ru/C and Ru7Pd3/C, prior and after the treatment, were accommodated inside a gas filter, and mass spectrometry investigations indicated that the thermal treatment only increased the methanation performance for the Ru/C catalyst. When used in anodic gas diffusion layer, this improvement was even more pronounced, and resulted in stationary methane production even at 85 &deg;C. The most efficient material for CO methanation was Ru/C thermally treated, that promoted the CO methanation in a preferable way even when CO2 was present with percentages as high as 25%. The increase of the electrochemical performance of the fuel cell with this catalyst in the diffusion layer was better when at 105 &deg;C.
568

Participação do sulfeto de hidrogênio na manutenção da homeostase hidroeletrolítica em resposta à privação hídrica de 24 horas / Participation of hydrogen sulfide in the maintenance of hydroelectrolytic homeostasis in response to 24-hour water deprivation

Ricardo Coletti 19 December 2013 (has links)
A manutenção da osmolalidade e do volume dos líquidos extra- (LEC) e intracelular (LIC) são fatores de extrema importância à conservação da vida. Na desidratação (por ingestão insuficiente ou perda excessiva de água), sistemas de controle autonômicos e endócrinos são acionados frente à ativação de barorreceptores (periféricos) e osmorreceptores (centrais e periféricos), visando estimular a sede e inibir o apetite ao sódio, além de reduzir a diurese, promover a natriurese e contrair a musculatura lisa dos vasos. Especificamente para o sistema de controle endócrino é evidente que tais respostas se dão pela secreção dos hormônios neuroipofisários vasopressina (AVP) e ocitocina (OT), e pelo aumento da concentração sanguínea de angiotensina II (ANGII). As secreções de AVP e OT são controladas por sistemas subjacentes, representados por neurotransmissores e também por moduladores gasosos, como óxido nítrico (NO) e monóxido de carbono (CO) (Calapai e cols., 1992; Ventura e cols., 2002 e 2008; Gomes e cols., 2004 e 2010; Reis e cols., 2010). Apesar da existência de modelos que investigassem a modulação do H2S sobre respostas hipocampais, modulação da frequência cardíaca e pressão arterial, e temperatura corporal (Abe e Kimura, 1996; Dawe e cols., 2008; Liu e cols., 2011; Ren e cols., 2011; Kwiatkoski e cols., 2012), nenhuma abordagem sobre a interação do H2S com a secreção de AVP e OT havia sido realizada. No presente estudo, portanto, objetivou-se avaliar, após a privação hídrica de 24 horas (estímulo potente à sede e secreção de AVP e OT), os efeitos do H2S sobre a resposta hipotalâmica. Para tanto, sulfeto de sódio (Na2S 65 mM, doador inorgânico), aminooxiacetato (AOA 50 ?M, inibidor da enzima cistationina ?-sintase) ou veículo (NaCl 0,9%) foram administrados intracerebroventricularmente (icv) em ratos adultos privados de água ou hidratados. Observou-se inicialmente que, em animais apenas submetidos à desidratação (vs. hidratados), houve um aumento da atividade das enzimas hipotalâmicas 8 geradoras de H2S; e, além disso, a administração aguda de Na2S a estes animais potencializou a secreção de AVP, OT e CORT (corticosterona), sem alterar a concentração plasmática de ANGII, ANP e prolactina (hormônios medidos após 5 min. da administração icv da droga ou veículo). O H2S exógeno foi também capaz de reduzir o conteúdo de NO hipotalâmico (medido indiretamente pelo metabólito nitrato/nitrito após 5 min.). O grande aumento na secreção plasmática de AVP e OT provavelmente foi o responsável pela maior concentração plasmática de CORT, uma vez que estes hormônios são secretagogos do hormônio adrenocorticotrófico (ACTH) adenoipofisário. Enquanto o aumento de OT pode ter sido o responsável pela redução da ingestão de água entre os animais privados. Inversamente, a administração de AOA (vs. veículo) aumentou a ingestão de água entre os animais desidratados. Desta forma, estes resultados sugerem que o gás H2S pode ser um importante agente modulador da resposta de sede e secreção neuroipofisária durante a privação hídrica; atuando ou diretamente sobre canais e receptores neuronais ou indiretamente através dos sistemas do NO e CO. / Osmolality and volume maintenance of extra- (ECF) and intracellular fluids (ICF) are factors of extreme importance to life preservation. During dehydration (from insufficient intake or excessive loss of water), autonomic and endocrine control systems are triggered mainly by (peripheral) baroreceptors and (central and peripheral) osmoreceptors to stimulate water intake and inhibit sodium appetite, in addition to restraining diuresis, promoting natriuresis and contracting smooth muscle of vessels. Specifically for endocrine control system, it is evident that such responses take place by neurohypophysis secretion of vasopressin (AVP) and oxytocin (OT), and by increase of plasma angiotensin II (ANGII) levels. Both AVP and OT secretion are controlled by underlying systems, which are represented by neurotransmitters and also by gaseous modulators like nitric oxide (NO) and carbon monoxide (CO) (Calapai et al., 1992; Ventura et al., 2002 and 2008; Gomes et al., 2004 and 2010; Reis et al., 2010). Despite the existence of models which investigated H2S modulation on hippocampus responses, heart frequency and blood pressure, and body temperature (Abe and Kimura, 1996; Dawe et al, 2008; Liu et al, 2011; Ren et al, 2011; Kwiatkoski et al, 2012), no approach of H2S interaction with AVP and OT secretion had been conducted. In this study, we thus aimed to evaluate the effects of H2S on hypothalamus response after a 24-hour water deprivation (a powerful stimulus for thirst and AVP/OT secretion). To that, 65 mM sodium sulfide (Na2S, inorganic donor), 50 ?M aminooxyacetate (AOA, cystathionine ?-synthase inhibitor) or vehicle (NaCl 0,9%) were administered intracerebroventricularly (icv) to water-deprived or euhydrated adult rats. It has been initially observed that hypothalamus H2S-generating enzymes activity of dehydrated-only animals was increased (vs. euhydrated); and, further, acute Na2S administration to dehydrated animals potentiated AVP, OT and CORT 10 (corticosterone) secretion without modifying ANGII, ANP and prolactin plasma levels (measured after 5 min. of drug or vehicle icv administration). Exogenous H2S could reduce hypothalamus NO content as well (indirectly measured by metabolite nitrate/nitrite after 5 min.). The great increase of AVP and OT secretion was probably responsible for higher levels of corticosterone, since these hormones are secretagogues of anterior pituitary adrenocorticotropic hormone (ACTH). While OT rise might have been the responsible for reduced water intake among deprived animals. On the other hand, AOA central injection (vs. vehicle) augmented water intake among water-deprived rats. These results therefore suggest that the gas H2S may be an important modulating agent of thirst and posterior pituitary secretion response during water deprivation; acting either directly on neuron channels and receptors or indirectly by NO and CO systems.
569

A metanandamida, um agonista canabinóide, protege a linhagem de neuroblastoma neuro2A da morte celular induzida por peróxido de hidrogênio. / The methanandamide, a cannabinoid agonist, protect the lineage of neuro 2A cell death induced by hydrogen peroxide.

Luciana Gonzalez Auad 02 July 2012 (has links)
As doenças neurodegenerativas são desordens progressivas que afetam determinadas populações neuronais do sistema nervoso central, levando a morte neuronal. Vários fatores contribuem para o desenvolvimento das doenças neurodegenerativas, dentre eles o aumento da formação de radicais livres e/ou estresse oxidativo. O sistema canabinóide vem sendo sugerido como um importante sistema neuroprotetor em diversos modelos de neurodegeneração. Os objetivos do presente estudo foram avaliar a participação do sistema canabinóide em um modelo de morte celular in vitro induzida pelo peróxido de hidrogênio. O modelo celular utilizado foi a linhagem Neuro 2A. Realizamos os tratamentos conjugados para verificar a possível função neuroprotetora do sistema canabinóide. Obtivemos resultados de neuroproteção da Metanandamida revertendo o quadro de morte celular induzido pelo peróxido de hidrogênio. Acreditamos que esta neuroproteção seja via CB1 que inibe os canais de cálcio dependentes de voltagem talvez contribuindo para a redução da progressão da excitotoxicidade. / Neurodegenerative diseases are progressive disorder affecting specific neuronal populations in the central nervous system, leading to neuronal death. Several factors contribute to the development of neurodegenerative diseases, including increased free radical formation and / or oxidative stress. The cannabinoid system has been suggested as an important system neuroprotective in several models of neurodegeneration. The objectives of this study were to evaluate the involvement of the cannabinoid system in a model of in vitro cell death induced by hydrogen peroxide. The model used was the cell line Neuro 2A. Performed the treatments combined to verify the possible neuroprotective effects of the cannabinoid system. We obtained results of neuroprotection Methanandamide reversing the framework of cell death induced by hydrogen peroxide. We believe that this is via neuroprotection CB1 that inhibits calcium channels of voltage-dependent perhaps contributing to the reduction of the progression of excitotoxicity.
570

Análise da permeação de H2O2 amelodentinária através de métodos eletroquímicos / Analysis of enameldentin permeation of H2O2 by electrochemical methods

Alexander Cassandri Nishida 24 April 2013 (has links)
Existem muitas metodologias utilizadas para tentar analisar a permeação de peróxido de hidrogênio através das estruturas dentárias, porém não conseguem determinar o momento exato em que o peróxido começa a alcançar concentrações detectáveis dentro da câmara pulpar. OBJETIVO: Investigar a viabilidade de um modelo experimental de análise eletroquímica para detecção e mensuração da concentração de peróxido de hidrogênio proveniente de produtos utilizados em tratamento clareador e avaliar a cinética da difusão destes peróxidos através dos tecidos duros dentários. MATERIAIS E MÉTODOS: Foram utilizados 45 dentes incisivos bovinos permanentes mandibulares, cujo preparo envolveu a remoção da face lingual coronária, mantendo-se o esmalte e a dentina vestibulares intactos. Todos os dentes foram fixados em resina acrílica com auxílio de matriz elastomérica quadrangular e organizados segundo os testes: 1: análise eletroquímica e 2: análise espectrofotométrica. Para os testes foram utilizados clareadores à base de peróxido de hidrogênio (HP) e de peróxido de carbamida (CP) e seus respectivos placebos (PHP e PCP). Foram realizados três cronoamperogramas e três voltamogramas para cada uma das amostras. Utilizou-se a mesma cela no experimento eletroquímico e no teste espectrofotométrico, permitindo assim a comparação das metodologias. RESULTADOS: A análise eletroquímica mostrou na 1ª permeação de HP média de 1688,50 segundos quando comparada a 857,70s e a 457,70s da 2ª e da 3ª permeações, respectivamente. Desta forma observa-se que a 1ª permeação representa aproximadamente o dobro e o quadruplo dos valores sequenciais da 2ª e da 3ª permeações. Não foi detectado início de permeação para CP, PHP e PCP. Para o grupo HP há uma relação crescente nas concentrações de moléculas de peróxido de hidrogênio detectadas nas três permeações respectivamente. Entretanto, o crescimento entre a 1ª e 2ª permeação é discreto, quando comparado à 3ª permeação, onde foi detectada maior concentração de moléculas do peróxido de hidrogênio. No grupo CP observam-se médias de 2,96E-02 A na 1ª permeação, 3,11E-05 A na 2ª permeação e 1,37E-04 A na 3ª permeação, havendo diferença entre a 1ª e 3ª permeação (p = 0,00472). Todavia, não ocorreram diferenças entre os demais grupos (p > 0,05). Quando comparado o método eletroquímico e o método espectrofotométrico, o peróxido de hidrogênio (HP) não demonstrou diferença significativa entre as análises (p =0,0826); todavia o peróxido de carbamida mostrou diferenças entre as duas análises (p=0,0093). CONCLUSÕES: A metodologia eletroquímica é tão eficaz quanto à metodologia consolidada na literatura para a detecção da presença de peróxido de hidrogênio na câmara pulpar, nos testes com peróxido de hidrogênio 35%. O tempo necessário para que o peróxido de hidrogênio chegasse à câmara pulpar diminuiu a cada aplicação e a penetração do peróxido de hidrogênio aumentou a permeabilidade dos tecidos duros dentais. / There are many methods used to analyze the permeation of hydrogen peroxide through the tooth structure, but they cannot determine the exact moment when the peroxide begins to reach detectable concentrations within the pulp chamber. OBJECTIVE: To investigate the feasibility of an experimental model of electrochemical analysis for detection and measurement of the concentration of hydrogen peroxide from products used in bleaching and evaluate the kinetics of diffusion of these peroxides through dental hard tissues. MATERIALS AND METHODS: We used 45 bovine permanent mandibular incisors, whose preparation involved removing the lingual coronary hard tissues keeping intact the vestibular enamel and dentin. All teeth were fixed in acrylic resin with the aid of elastomeric matrix square and organized according to the tests: 1: electrochemical analysis and 2: spectrophotometric analysis. For tests were used based bleaching hydrogen peroxide (HP) and carbamide peroxide (CP) and their respective placebos (PHP and PCP). Three cronoamperograms and three voltammograms were performed for each sample. We used the same cell to the spectrophotometric test, thus allowing comparison of methodologies. RESULTS: The analysis showed the 1st electrochemical permeation HP average of 1688.50 seconds when compared to 857.70s and 457.70s of the 2nd and 3rd permeations respectively. Thus we observe that the 1st permeation is approximately double and quadruple sequential values of the 2nd and the 3rd permeations. Not detected early permeation for CP, PHP and PCP. For Group HP there is a ratio of molecules increasing concentrations of hydrogen peroxide detected in three permeations respectively. However, the growth between the 1st and 2nd permeation is understated when compared to 3rd permeation, where there has been a greater concentration of molecules of hydrogen peroxide. In the CP group were observed averages of 2.96 E-02A in the 1st permeation, 3.11 E-05 A in the 2nd permeation and 1.37 E-04 A in 3rd permeation, no difference between 1st and 3rd permeation (p = 0.00472) . However, there were no differences between the other groups (p> 0.05). When compared the electrochemical and spectrophotometric methods, hydrogen peroxide (HP) showed no significant difference between the analysis (p = 0.0826), yet the carbamide peroxide showed differences between the two analyzes (p = 0.0093). CONCLUSIONS: The electrochemical method is as effective as the consolidated methodology in the literature to detect the presence of hydrogen peroxide in the pulp chamber, in the tests with hydrogen peroxide 35%. The time required for the hydrogen peroxide to reach the pulp chamber decreased to each application and the penetration of hydrogen peroxide increased the permeability of dental hard tissues.

Page generated in 0.0379 seconds