• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 978
  • 16
  • 15
  • 15
  • 15
  • 9
  • 7
  • 7
  • 6
  • 4
  • 3
  • 3
  • 1
  • 1
  • 1
  • Tagged with
  • 1002
  • 654
  • 321
  • 225
  • 114
  • 103
  • 95
  • 82
  • 80
  • 79
  • 74
  • 71
  • 70
  • 66
  • 61
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
811

EFEITO DE DOIS ANTI-INFLAMATÓRIOS E UM ANTIOXIDANTE NA PREVENÇÃO DA SENSIBILIDADE CAUSADA PELO CLAREAMENTO DENTAL / Effect of two anti-inflammatories and one antioxidant to prevent bleaching-induced tooth sensitivity

Paula, Eloisa Andrade de 05 December 2013 (has links)
Made available in DSpace on 2017-07-24T19:22:32Z (GMT). No. of bitstreams: 1 Eloisa Andrade de Paula.pdf: 11594237 bytes, checksum: 25299b2f989c0877ee886949439d03c9 (MD5) Previous issue date: 2013-12-05 / Fundação Araucária de Apoio ao Desenvolvimento Científico e Tecnológico do Paraná / The tooth bleaching has a long history of tooth sensitivity (TS). This study aimed to determine the effect of different drugs, administered perioperatively, on tooth sensitivity and the degree of tooth whitening after in-office bleaching. A triple-blind,parallel design, randomized clinical trial were conducted. In the first experiment, the participants received a placebo or 400 mg ibuprofen every 8 h while in the second experiment, they were given a placebo or 60 mg etoricoxib every 24 h. In the third experiment, they received a placebo or 500 mg ascorbic acid every 8 h. In all experiments, the first dose of the drug was administered 1 h before in-office bleaching and taken for a period 48 h. The 35% hydrogen peroxide gel (Whiteness HP Maxx, FGM) was used in three 15-min applications for three groups following the manufacturer's directions. The in-office bleaching agent was refreshed every 15 min.Two bleaching sessions, with a one-week interval, were performed on each patient. The shade evaluation were performed before and 30-days, after bleaching with a Vita Easy Shade spectrophotometer and a Vita Classical’s visual shade guide. The tooth sensitivity was recorded on three scales: the five-point verbal rating scale, the 101 points scale, and the visual analogue scale, of and in different time points up to 1 h, 24 h, 48h after bleaching. The % of patients that reported TS at least once during treatment were evaluated by Fisher`s exact and the intensity of tooth sensitivity with Mann-Whitney test. Tooth color changes were evaluated by repeated ANOVA measures and t-test. There were no significant differences in the % of patients with tooth sensitivity and color change between the groups. The lowest tooth sensitivity was observed in the 400 mg ibuprofen group only up to 1 h post bleaching. The perioperative use of ibuprofen, etoricoxib and ascorbic acid per oral route was not able to avoid bleaching-induced tooth sensitivity according to the posology and dose used in this study. However, the 400 mg ibuprofen was able to reduce the intensity of tooth sensitivity up to 1 h post bleaching. / As técnicas de clareamento dental em dentes vitalizados podem apresentar o inconveniente de causarem sensibilidade dental. Neste estudo foram realizados três experimentos com o objetivo de determinar o efeito de dois anti-inflamatórios e um antioxidante utilizados previamente e durante o procedimento de clareamento dental em consultório na sensibilidade dental e no grau de clareamento alcançado. Estes experimentos foram do tipo estudo clínico, randomizado, paralelo, controlado por placebo e triplo cego. No experimento 1, os participantes receberam placebo ou ibuprofeno 400 mg a cada 8 h. No experimento 2, os participantes receberam placebo ou etoricoxibe 60 mg a cada 24 h. No experimento 3, os participantes receberam placebo ou ácido ascórbico 500 mg a cada 8 h. Em todos os experimentos os medicamentos foram administrados 1 hora antes do início do tratamento clareador por um período total de 48 h. Em cada sessão de clareamento, o gel de peróxido de hidrogênio 35% (Whiteness HP Maxx, FGM) foi aplicado 3 vezes durante 15 minutos cada, de acordo com as instruções do fabricante e repetido depois de uma semana, seguindo o mesmo protocolo. As alterações de cor foram avaliadas antes e 30 dias após o tratamento clareador utilizando o espectrofotômetro Vita Easy Shade e a escala de cor Vita Clássica organizada por ordem de valor. Três escalas destinadas a avaliar a intensidade da dor (escala verbal de 5 pontos, escala numérica de 101 pontos e escala visual analógica) foram utilizadas para determinar o nível de sensibilidade imediatamente até 1 h, 24 h e 48 h após o tratamento de clareamento em consultório. A porcentagem de pacientes que relataram sensibilidade, ao menos uma vez durante o tratamento, e a intensidade da sensibilidade dental foram avaliadas pelo teste exato de Fischer e teste de Mann-Whitney, respectivamente. As alterações de cor dental foram determinadas por medidas repetidas ANOVA 1 critério e teste t. Não foram detectadas diferenças significativas no percentual de pacientes que apresentaram sensibilidade e nem na alteração de cor. Somente o medicamento ibuprofeno 400 mg apresentou redução da intensidade da sensibilidade na primeira hora após o tratamento clareador. Os medicamentos não foram capazes de prevenir e nem mesmo minimizar a sensibilidade dental quando administrados de acordo com a posologia e dose empregadas neste estudo.
812

Penetração do peróxido de hidrogênio em diferentes concentrações na câmara pulpar e o manejo da sensibilidade pós-operatória em clareamento dental

Parreiras, Sibelli Olivieri 27 October 2017 (has links)
Submitted by Angela Maria de Oliveira (amolivei@uepg.br) on 2017-10-27T12:19:28Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Tese Sibelli.pdf: 2029440 bytes, checksum: b214f3a9a9cf1dd6ccca621c7ae4fae6 (MD5) / Made available in DSpace on 2017-10-27T12:19:28Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Tese Sibelli.pdf: 2029440 bytes, checksum: b214f3a9a9cf1dd6ccca621c7ae4fae6 (MD5) Previous issue date: 2017-10-27 / Os objetivos deste estudo foram 1) quantificar a concentração do peróxido de hidrogênio (PH) de géis clareadores com diferentes concentrações do mesmo fabricante, 2) quantificar a concentração de PH na câmara pulpar em dentes com aplicação prévia de agentes dessensibilizantes ao clareamento de consultório e 3) avaliar o efeito de um gel dessensibilizante experimental na sensibilidade pósoperatória de pacientes submetidos a clareamento de consultório. Para os estudos 1 e 2, a quantificação de PH na câmara pulpar foi realizada por meio do método espectrofotométrico com a enzima horseradish peroxidase. No estudo 1, foram divididos aleatoriamente 90 dentes em nove grupos (n = 10) e submetidos a diferentes concentrações de gel clareador de mesmo fabricante, simulando o procedimento clareador caseiro e de consultório. No estudo 2, 50 dentes foram selecionados e os diferentes agentes dessensibilizantes: Desensibilize KF 2%, Mi Paste e Desensibilize Nano-P foram aplicados previamente ao clareamento de consultório com PH 35%. No estudo 3, 42 pacientes com os caninos com cor A2 ou mais escuros foram selecionados e divididos aleatoriamente em dois grupos: placebo (controle negativo) e tratamento. Os pacientes do grupo tratamento foram submetidos ao gel experimental a base de nitrato de potássio 5% e glutaraldeído 5% por 10 min previamente ao clareamento de consultório com PH 35%. A sensibilidade dental foi avaliada imediatamente, após 1 h, 24 h e 48 h do clareamento e registradas pelos próprios pacientes por meio das escalas numéricas de 5 pontos e visual analógica. A cor foi avaliada através da escala Vita classical, Vita Bleachedguide e espectrofotômetro Vita Easyshade (Vita Zahnfabrik, Bad Sackingen, Alemanha), inicialmente, 1 semana após cada sessão e um mês depois do término do procedimento. Os dados dos experimentos 1 e 2 foram avaliados por análise de variância (ANOVA) e teste de tukey para o contraste das médias ( = 0,05). Para a análise do risco de sensibilidade dental no estudo 3, os dados foram analisados por meio do teste Mc Nemar e a mudança de cor por teste t de Student ( = 0,05). Foi observado que a quantidade de PH que alcançou a câmara pulpar no grupo clareamento de consultório foi significativamente maior em comparação aos clareamentos caseiro (p = 0,65). Enquanto que os protocolos caseiros apresentaram resultados similares. O uso de agentes dessensibilizantes previamente ao clareamento de consultório reduziu a passagem de PH para a câmara pulpar, de forma que os dessensibilizantes Mi Paste e Nano-P tiveram menor concentração de PH na câmara pulpar (p < 0,001). Foi também possível observar que o risco de sensibilidade dentária do grupo gel dessensibilizante [31,7% (95% IC 19,6 – 46,9)] e para o grupo controle [70,7 (95% IC 55,5 – 82,3%) foram estatisticamente significante (p < 0,0001). Pode-se concluir que fatores como concentração do gel clareador e o uso prévio de agentes dessensibilizantes interferem na difusão do PH, porém a utilização do gel experimental à base de nitrato de potássio 5% e glutaraldeído 5% foi eficaz na redução da sensibilidade pós-operatória em pacientes submetidos a clareamento de consultório. / The objectives of this study were: 1) to evaluate the diffusion of hydrogen peroxide (HP) of bleaching gels with different concentrations from the same manufacturer, 2) quantify the HP concentration in the pulp chamber in teeth with prior application of desensitizing agents and 3) evaluate the effect of an experimental desensitizing gel on the postoperative sensitivity of patients undergoing in-office tooth bleaching. For studies 1 and 2, the quantification of HP in the pulp chamber was performed using the spectrophotometric method with the horseradish peroxidase enzyme. In study 1, 90 teeth were randomly divided into nine groups (n = 10) and submitted to different concentrations of whitening gel from the same manufacturer, simulating the home and in-office whitening procedure. In study 2, 50 teeth were selected at the different desensitizing agents: Desensibilize KF 2%, Mi Paste and Desensibilize Nano-P were applied prior to the office bleaching. In study 3, 42 patients with canines with A2 or darker color were selected and randomly divided into two groups: placebo (negative control) and treatment. Patients in the treatment group were submitted to 5% potassium nitrate and 5% glutaraldehyde gel for 10 min prior to bleaching with 35% hydrogen peroxide. The dental sensitivity was evaluated immediately, after 1 h, 24 h and 48 h of the bleaching and registered by the patients themselves through the numerical scales of 5 points and visual analog. The color was evaluated through the Vita classical, Vita Bleachedguide and Vita Easyshade spectrophotometer (Vita Zahnfabrik, Bad Sackingen, Germany), initially, 1 week after each session and one month after the end of the procedure. Data from experiments 1 and 2 were evaluated by analysis of variance (ANOVA) and tukey test for the means contrast ( = 0.05). For the analysis of the risk of dental sensitivity in study 3, the data were analyzed using the Mc Nemar test and the color change by Student's t-test ( = 0.05). It was observed that the amount of HP that reached the pulp chamber in the office bleaching group was significantly higher compared to home bleaching (p = 0.65). The home protocols presented similar results. The use of desensitizing agents prior to the office bleaching reduced the passage of HP to the pulp chamber, so that the desensitizers Mi Paste and Nano-P had lower HP concentrations in the pulp chamber (p < 0.001). It was also possible to observe that the risk of tooth sensitivity of the desensitizing gel group [31.7% (95% CI 19.6 - 46.9)] and for the control group [70.7 (95% CI 55.5 - 82.3%) were statistically significant (p < 0.0001). It can be concluded that factors such as concentration of the bleaching gel and the previous use of desensitizing agents interfere in the diffusion of PH, but the use of the experimental gel based on 5% potassium nitrate and 5% glutaraldehyde was effective in reducing post-operative in patients undergoing in-office tooth bleaching.
813

Aplicação de ozônio e ozônio + peróxido de hidrogênio para remoção de compostos recalcitrantes em lixiviados de aterros sanitários / Application of ozone and ozone + hydrogen peroxide to remove of recalcitrant compounds in landfill leachates

Schoenell, Elisa Kerber 28 February 2013 (has links)
Submitted by Maicon Juliano Schmidt (maicons) on 2015-07-06T14:05:57Z No. of bitstreams: 1 Elisa Kerber Schoenell.pdf: 1100203 bytes, checksum: 7fc798f66b493b73d31a96dbbf676ff3 (MD5) / Made available in DSpace on 2015-07-06T14:05:57Z (GMT). No. of bitstreams: 1 Elisa Kerber Schoenell.pdf: 1100203 bytes, checksum: 7fc798f66b493b73d31a96dbbf676ff3 (MD5) Previous issue date: 2013-02-28 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / CNPQ – Conselho Nacional de Desenvolvimento Científico e Tecnológico / FINEP - Financiadora de Estudos e Projetos / Ministério da Ciência e Tecnologia / Os lixiviados são efluentes gerados em depósitos de resíduos sólidos, através da decomposição da matéria orgânica, somados as águas de infiltração e a materiais suspensos. Ele possui compostos biodegradáveis e recalcitrantes - de difícil degradação biológica (biodegradação). Este efluente necessita de um tratamento antes de ser disposto no meio ambiente. O objetivo deste trabalho foi avaliar o uso de ozônio (O3) e peróxido de hidrogênio (H2O2) como processo oxidativo avançado (POA), visando a remoção de compostos recalcitrantes em lixiviados de aterros sanitários. Foram utilizados dois lixiviados provenientes do aterro sanitário de São Leopoldo/RS: bruto e tratado por lagoas, os quais foram tratados apenas por O3 em concentração de 29 mg/L (gerados a partir de processo corona) ou com adição de 1000 mg/L de H2O2 ao O3. Os ensaios ocorreram em escala piloto, sendo tratados 460 L de lixiviado em cada ensaio, os quais tiveram duração de 96 horas. O POA (operando com os oxidantes O3 e O3 + H2O2) mostrou-se mais eficiente no tratamento de lixiviados que tiveram as menores concentrações iniciais de DBO, DQO e COT, independente de ser lixiviado bruto ou tratado. Altas remoções de cor aparente, DQO e COT foram observadas, chegando a 99%, 88% e 66%, respectivamente. A maior remoção de carbono inorgânico foi 23%, porém o grupo que iniciou com a maior concentração desse parâmetro, obteve as maiores remoções para todos os outros parâmetros estudados. A adição de H2O2 aumentou a eficiência de remoção de todos os parâmetros analisados, porém não de forma significativa. Observou-se necessidade de tratamento complementar ao POA deste estudo. / Leachates are wastewaters generated at sites of solid waste disposal through organic matter decomposition, added to infiltration waters and suspended materials. It contains biodegradable and recalcitrant compounds - difficult to biological degradation (biodegradation). This wastewater requires treatment before being disposed in the environment. The aim of this study was to evaluate the use of ozone (O3) and hydrogen peroxide (H2O2) as advanced oxidation process (AOP), in order to removal recalcitrant compounds in landfill leachate. It was used two leachates from São Leopoldo/RS landfill: raw and treated in pounds, which were treated only with O3 at a concentration of 29 mg/L (generated from the corona process) or with addition of 1000 mg/L H2O2 to O3. The tests occurred on a pilot scale, treating 460 L of leachate in each test, which lasted 96 hours. OAP (operating with the oxidants O3 and O3 + H2O2) was more efficient in the treatment of leachate that had the lowest initial concentrations of BOD, COD and TOC (both raw and treated leachate).. High removals of apparent color, COD and TOC were observed, reaching 99%, 88% and 66%, respectively. The greater removal of inorganic carbon was 23%, but the group that started with the highest concentration of these parameter, achieve the greatest removals for all others parameters studied. The addition of H2O2 increased the efficiency of removal of all parameters, but not significantly. It was observed need of additional treatment to the POA of this study.
814

Avaliação da remoção de cor e desinfecção de lixiviados de aterro sanitário utilizando ozônio e peróxido de hidrogênio / Evaluation of color and disinfection of landfill leachate using ozone and hydrogen peroxide

Seewald, Marina Medtler 28 February 2013 (has links)
Submitted by Maicon Juliano Schmidt (maicons) on 2015-07-06T19:15:18Z No. of bitstreams: 1 Marina Medtler Seewald.pdf: 3415895 bytes, checksum: a88885e13dc4a2b54ba496bc5a0fd0b7 (MD5) / Made available in DSpace on 2015-07-06T19:15:18Z (GMT). No. of bitstreams: 1 Marina Medtler Seewald.pdf: 3415895 bytes, checksum: a88885e13dc4a2b54ba496bc5a0fd0b7 (MD5) Previous issue date: 2013-02-28 / CNPQ – Conselho Nacional de Desenvolvimento Científico e Tecnológico / FINEP - Financiadora de Estudos e Projetos / Ministério da Ciência e Tecnologia / A degradação de resíduos dispostos em aterro sanitário gera um líquido com alto potencial poluidor caracterizado por sua coloração escura, alto teor de matéria orgânica e de nitrogênio amoniacal. O lixiviado de aterro sanitário pode ainda conter micro-organismos patogênicos provenientes de resíduos contaminados com excreções humanas, representando risco à saúde. Para o tratamento de lixiviado de aterro sanitário, processos biológicos tem mostrado eficiência, especialmente na remoção de matéria orgânica. No entanto, para que se atinja eficiência de remoção desejada para atendimento à legislação, especialmente em lixiviados antigos, um pós-tratamento se faz necessário. O emprego de processos oxidativos avançados (POAs) tem mostrado boa eficiência na remoção de cor, destruição de organismos patogênicos e aumento de biodegradabilidade em efluentes recalcitrantes. O objetivo deste trabalho foi avaliar a remoção de cor e desinfecção de lixiviado de aterro sanitário através do emprego de ozônio e peróxido de hidrogênio como agentes oxidantes. Para tanto, foram realizados doze ensaios no sistema POA instalado para tratar lixiviado bruto e tratado por sistema de lagoas. Seis ensaios foram realizados somente com ozônio e os outros seis com ozônio combinado com peróxido de hidrogênio. O sistema POA possuía volume útil de 460L e os ensaios tiveram a duraçãode 96h. A concentração de ozônio (gás) foi de 29 mg/L e a de peróxido de hidrogênio (adicionado em solução líquida) foi de 1000 mg/L no lixiviado. Com a caracterização do lixiviado, verificou-se alta variabilidade das características dos lixiviados gerados no aterro sanitário de São Leopoldo. Portanto, para a discussão dos resultados de remoção de cor, optou-se por dividir os ensaios realizados por grupos, utilizando como critério para a divisão a concentração inicial de cor verdadeira no lixiviado estudado. Embora inicialmente os resultados indiquem uma similiaridade entre os oxidantes testados a análise de variância de dois fatores realizada com medidas repetidas comprovou que houve diferença entre os agentes os oxidantes utilizados na remoção de cor, sendo observado que o peróxido de hidrogênio apresentou melhor desempenho. Foi observado que quanto menor a concentração inicial de cor verdadeira, mais rápida foi sua remoção. Na desinfecção do lixiviado, os ensaios utilizando ozônio e peróxido de hidrogênio apresentaram maiores taxas de inativação de coliformes termotolerantes, sugerindo que o acréscimo do segundo oxidante foi adequada. A turbidez e matéria orgânica presentes no lixiviado não impediram que a desinfecção ocorresse. Todos os ensaios realizados alcançaram mais de 90% de eficiência na remoção de cor verdadeira em 96h de ensaio e mais de 92% de eficiência na eliminação de coliformes termotolerantes em 24h. / Degradation of grounded waste in landfill generates a liquid with high pollution potential characterized by its dark color, high concentration of organic matter and ammonia nitrogen. Landfill leachate may still contain pathogenic microorganisms from wastes contaminated by human excreta, presenting health risk. For treating landfill leachate, biological processes have shown good performance, especially in organic matter removal. However, in order for the removal efficiency to attain local legislation, particularly in older leachate, a post treatment is necessary. Use of advanced oxidation processes has shown efficiency in color removal, destruction of pathogens and increased biodegradability of recalcitrant effluents. The purpose of this study is to evaluate color removal and disinfection of landfill leachate using ozone and hydrogen peroxide as oxidizing agents. Therefore, twelve experiments were performed in AOP system treating raw and treated leachate by pond system. Six tests were conducted with ozone only and six combining ozone and hydrogen peroxide. The POA was operated with volume of 460L and tests were carried out for 96h. The ozone (gas) concentration was 29 mg/L and hydrogen peroxide (liquid solution added) was 1000 mg/L in the leachate. Characterization of landfill leachate generated in São Leopoldo showed high variability. Therefore, to discuss results of color removal, groups of tests were created using like criteria true color concentration. Although attained results indicated similarity between tested oxidants, performed ANOVA two factors with repeated measures showed difference between oxidizing agents used in color removal. Hydrogen peroxide outperformed ozone alone. True color removal occured faster with smaller true color concentrations. The disinfection of the leachate, using ozone combined with hydrogen peroxide showed higher inactivation rates of fecal coliforms. Turbidity and organic matter in the leachate did not prevent the disinfection. All tests reached over 90% efficiency in true color removal at 96h and over 92% efficiency in disinfection within 24h.
815

Avaliação da eficácia de clareamento, permeabilidade e morfologia superficial do esmalte submetido a diferentes técnicas de aplicação do peróxido de hidrogênio a 35%, após aplicação de flúor / Evaluation of the effectiveness of whitening, morphlogy and perneability of enamel surface under different techniques for application of a hydrogen peroxide 35% after application of fluoride

Renato Jonas dos Santos Schiavoni 31 March 2010 (has links)
Alterações visuais, histoquímicas e micromorfológicas podem ser observadas em superfícies dentais submetidas ao clareamento, desencadeando sensibilidade, menor resistência ao desgaste, maior manchamento e aderência bacteriana. Uma forma de verificar a ocorrência de danos superficiais e sub-superficiais é através da permeabilidade e da avaliação superficial por meio de microscopia eletrônica de varredura. Assim, este estudo in vitro teve por objetivo avaliar a eficácia de clareamento em dentes manchados, a permeabilidade e a morfologia superficial do esmalte dental após tratamento com diferentes técnicas de aplicação do peróxido de hidrogênio a 35% (FGM) seguido ou não da aplicação de flúor. Foram utilizados 260 incisivos bovinos, com superfícies de esmalte de 10x10 mm de área. Após, os espécimes foram casualmente distribuídos (n = 10) e submetidos ao manchamento com café, chá preto e vinho tinto por 72 horas. As medidas de cor eram realizadas com espectrofotômetro de reflexão nos tempos inicial, após o manchamento e logo após a fase de clareamento. Após o período de manchamento os fragmentos eram clareados com peróxido de hidrogênio a 35% (FGM) - convencional, ativado com LED ou laser de Er:YAG seguido ou não da aplicação de flúor (Desensibilize KF 2%, FGM). Os grupos controles eram expostos: a saliva artificial e a aplicação de flúor + saliva artificial. O tratamento clareador foi realizado de acordo com as recomendações do fabricante. No restante do período diário, os espécimes eram imersos em saliva artificial. A seguir, os fragmentos foram subdivididos em dois fragmentos de aproximadamente 5x5 mm de área, sendo um submetido à avaliação da permeabilidade e o outro a avaliação da superfície do esmalte através de microscopia eletrônica de varredura. O método de coloração histoquímica foi utilizado para evidenciar a extensão da permeabilidade no esmalte. Do esmalte eram obtidos três cortes avaliados em microscopia óptica, através de um software de digitalização de imagem (Axion Vision 3.1) verificando a penetração dos íons cobre em relação à espessura total do esmalte. As fotomicrografias eletrônicas de varredura das superfícies vestibulares do esmalte, com aumento de 2000X, foram digitalizadas e avaliadas. Para as análises estatísticas, foi considerado o valor de alteração de cor de cada fragmento nos diferentes tempos de observação e a média das três secções de um mesmo dente para a avaliação da permeabilidade. Em relação à MEV observou-se que em relação aos processos de clareamento, foi encontrado diferenças quando comparadas aos grupos controles. Os grupos controles apresentaram superfícies dentais lisas e regulares. Já os grupos tratados com PH35% e PH 35% + LED apresentaram superfícies dentais marcadas pela presença dos prismas de esmalte suavemente esboçados em meio a um esmalte interprísmático de textura lisa. A aplicação do Er:YAG promoveu a remoção da camada aprismática e exposição clara dos prismas de esmalte, depressões, tornando a superfície porosa e irregular. Nos grupos em que se aplicou o flúor, independente do tipo de clareamento realizado, observou-se superfícies relativamente cobertas por um precipitado fusiforme. Em relação à permeabilidade, os resultados demonstraram não haver diferença significativa. Já em relação à alteração de cor foi encontrada diferença estatística ente o agente aplicado ativado pelo Er:YAG, o método a alcançar as tonalidades de cor mais claras, quando comparado aos métodos convencional e ativado pelo LED. Concluímos que novos estudos são necessários para que se estabeleçam parâmetros adequados e seguros para a aplicação do laser. Isso fará com que se consiga não só melhor tonalidade de cor, mas menores efeitos deletérios na morfologia superficial do esmalte clareado. / Visual changes, micromorphological and histochemical can be observed in areas subjected to dental bleaching, triggering sensitivity, lower wear resistance, increased staining and bacterial adhesion. One way to check the damage to surface and subsurface is through the permeability and surface evaluation by scanning electron microscopy. Thus, this in vitro study was to evaluate the effectiveness of whitening stained teeth, permeability and morphology of enamel after treatment with different techniques of application of hydrogen peroxide 35% (FGM) whether or not the application of fluoride . We used 260 bovine incisors with enamel surfaces of 10x10 mm in size. After, the specimens were randomly distributed (n = 10) and subjected to staining with coffee, black tea and red wine for 72 hours. The color measurements were made at a reflection spectrophotometer in early times, after staining and after the bleaching stage. After the period of staining the fragments were bleached with hydrogen peroxide 35% (FGM) - conventional activated LED or laser Er:YAG whether or not the application of fluoride (KF Desensibilize 2%, FGM). Control groups were exposed: the artificial saliva and fluoride application + artificial saliva. The bleaching treatment was performed according to the manufacturer\'s recommendations. The rest of the daily period, the specimens were immersed in artificial saliva. Next, the fragments were divided into two fragments of approximately 5x5 mm in size, being submitted to an evaluation of the permeability and the other to evaluate the enamel surface by scanning electron microscopy. The histochemical staining method was used to show the extent of the permeability of enamel. Enamel were obtained from three sections evaluated with optical microscopy, using a software image scanning (Axion Vision 3.1) verifying the penetration of copper ions in relation to the total thickness of enamel. The images of scanning electron photomicrographs of the vestibular enamel, an increase of 2000X were scanned and evaluated. For statistical analysis, we considered the color change of each fragment in different observation times and the average of three sections of the same tooth for assessing permeability. Regarding the SEM showed that in relation to the bleaching procedure, we found differences when compared to control groups. The control groups showed tooth surfaces smooth and regular. Since the groups treated with PH35% and 35% PH + LED tooth surfaces showed marked by the presence of enamel rods gently outlined in the midst of an enamel interprismatic smooth texture. The application of Er:YAG promoted the removal of the layer aprismatic and clear statement of the enamel prisms, depressions, making the surface porous and irregular. In groups that applied fluoride, regardless of the type of bleaching done, it was observed on surfaces covered by a precipitate fusiform. In relation to permeability, the results showed no significant difference. In relation to the color change was statistical difference between individual agents used and the Er:YAG method to achieve the color shades lighter when compared to PH35 and PH35% + LED. We conclude that further studies are needed to find themselves safe and appropriate parameters for the laser application. This will make you not only get better color tone, but less deleterious effects on enamel surface morphology cleared.
816

Efeito do peptídeo-1 semelhante ao glucagon endógeno sobre a atividade do NHE3 em túbulo proximal renal / Effect of endogenous glucagon like peptide-1 on NHE3 activity in the renal proximal tubule

Farah, Livia Xavier Soares 22 July 2015 (has links)
O peptídeo-1 semelhante ao glucagon (GLP-1) é um hormônio incretina secretado pelas células L do trato gastrointestinal e liberado imediatamente após a ingestão de alimento. O GLP-1 estimula a secreção de insulina pós-prandial moderando a elevação precoce da glicose no sangue. Embora primariamente envolvido na homeostase da glicose, o GLP-1 é capaz de induzir a diurese e natriurese, quando administrado em doses farmacológicas em humanos e em roedores. Estudos prévios do nosso laboratório demonstraram que o mecanismo de ação renal do GLP-1, bem como de agonistas sintéticos do receptor GLP-1R, envolve o aumento do fluxo plasmático renal (FPR) e do ritmo de filtração glomerular (RFG) bem como a diminuição da reabsorção de sódio dependente da isoforma 3 do trocador Na?/H? (NHE3) em túbulo proximal renal. Entretanto, até o momento, nenhum estudo investigou se o GLP-1 endógeno exerce efeitos sobre o manuseio renal de sal e água, nem o seu papel fisiológico sobre a regulação da atividade do NHE3. Portanto, o objetivo deste estudo foi testar a hipótese que o GLP-1 endógeno modula a função renal de ratos, ao menos em parte, via inibição da atividade do NHE3 em túbulo renal. Para este fim, ratos Wistar (2-3 meses de idade) foram devidamente anestesiados, submetidos à traqueostomia e tiveram a veia jugular e a bexiga canuladas para infusão de uma solução contendo 100 ug/kg/min do antagonista do receptor GLP-1R exendin-9 (Ex-9, 40 uL/min) por um período de 30 minutos e para a coleta de urina, respectivamente. A infusão sistêmica de Ex-9 diminuiu a concentração de AMPc urinário e atividade da PKA cortical renal consistente com o bloqueio da sinalização deflagrada pela interação GLP-1/GLP-1R no rim. Além disso, a administração sistêmica de Ex-9 reduziu a diurese, natriurese, RFG, FPR, clearance de lítio e pH urinário. Em experimentos de microperfusão estacionária in vivo, não foram observadas diferenças no fluxo de bicarbonato dependente de NHE3 entre os túbulos proximais perfundidos com exendin-9 (2 uM) e os túbulos perfundidos com solução controle. No entanto, a perfusão tubular proximal com Ex-9 foi capaz de bloquear completamente as ações inibitórias do GLP-1 (20 nM) sobre a atividade do NHE3. Por outro lado, a infusão sistêmica do Ex-9 reduziu os níveis de fosforilação da serina 552, sítio consenso para a fosforilação por PKA localizado na região C-terminal do NHE3, e que está associado à inibição da atividade de troca Na+/H+ mediada por este transportador. Baseando-se nos achados que a infusão sistêmica do Ex-9 aumenta a reabsorção de sódio e secreção de H?, reduz o clearance do lítio e os diminui os níveis de fosforilação do NHE3 na serina 552 são consistentes com um aumento na atividade deste transportador na ausência/redução da sinalização mediada pela interação do GLP-1 endógeno com seu receptor no rim. Por sua vez, o fato do Ex-9 não afetar a atividade do NHE3 sob as condições experimentais da microperfusão estacionária in vivo é condizente com o fato do GLP-1 não ser sintetizado no néfron e sugere fortemente que é o GLP-1 filtrado que se liga ao seu receptor no túbulo proximal renal resultando na diminuição da reabsorção de bicarbonato de sódio mediada pelo NHE3. Em conjunto, estes resultados sugerem que o GLP-1 endógeno exerce efeito tônico sobre o manuseio renal de sódio e água, mediando portanto, uma relação funcional entre a homeostase glicêmica e volêmica / The glucagon like peptide-1 (GLP-1) is an incretin hormone secreted by the L-cells of the gastrointestinal tract and released immediately after ingestion of food. GLP-1 stimulates postprandial insulin secretion moderating early increase in blood glucose. Although primarily involved in glucose homeostasis, GLP-1 is capable of inducing diuresis and natriuresis when administered in pharmacologic doses in humans and rodents. Previous studies from our laboratory have shown that the renal mechanism of action of GLP-1 and synthetic agonists of GLP-1R receptor, involves an increase of renal plasma flow (RPF) and glomerular filtration rate (GFR) as well a decrease in reabsorption of sodium mediated by the Na? / H? exchanger (NHE3) isoform 3 in the renal proximal tubule. However, to date, no study has investigated whether endogenous GLP-1 exerts effects on the renal handling of salt and water, or its physiological role in the regulation of the activity of NHE3. Therefore, the aim of this study was to test the hypothesis that endogenous GLP-1 modulates renal function in rats, at least in part, via inhibition of the NHE3 in renal tubule. To this end, male Wistar rats (2-3 months old) were properly anesthetized, tracheostomized and the jugular vein and the bladder were cannulated to the infusion of a solution containing 100 ug / kg / min GLP-1R antagonist receiver exendin-9 (Ex-9, 40 uL/min) for a period of 30 minutes and to collect urine, respectively. Systemic infusion of Ex-9 reduced the urinary concentration of cAMP and the renal cortical PKA activity, consistent with the blockage of the signal triggered by the interaction of GLP-1 / GLP-1R in the kidney. Furthermore, systemic administration of ex-9 reduced diuresis, natriuresis, GFR, RPF, lithium clearance and urinary pH. In experiments of in vivo stationary microperfusion, no differences were observed in the NHE3-mediated net bicarbonate flow between proximal tubules perfused with exendin-9 (2 mM) and perfused tubules with control solution. However, the tubular proximal perfusion with Ex-9 was able to completely block the inhibitory actions of GLP-1 (20 nM) on the activity of NHE3. On the other hand, systemic infusion of Ex-9 reduced phosphorylation levels of serine 552, a consensus site for phosphorylation by PKA located in the C-terminal region of NHE3, which is associated with inhibition of exchange activity of Na+/H+ mediated by this transporter. Collectively, the findings that systemic infusion of Ex-9 increases sodium reabsorption and secretion of H+, reduces the lithium clearance and decreases the NHE3 phosphorylation at serine 552 levels are consistent with the idea that NHE3 activity is upregulated in the absence/reduction of the signaling cascade mediated by the interaction of the endogenous GLP-1 with its receptor in the kidney. In turn, the fact Ex-9 does not affect the activity of NHE3 under the experimental conditions of stationary microperfusion in vivo is consistent with the fact that GLP-1 is not synthesized in the nephron. Besides, it strongly suggests that is the filtrated GLP-1 that binds to its receptor in renal proximal tubule, resulting in a decrease in NHE3-mediated sodium bicarbonate reabsorption. Taken together, these results suggest that endogenous GLP-1 exerts a tonic effect on renal sodium and water handling, mediating therefore a functional relationship between volume and glucose homeostasis
817

Fabricação, caracterização do comportamento eletroquímico e aproveitamento analítico de eletrodos modificados para a determinação de peróxido de hidrogênio / Fabrication, characterization of the electrochemical behavior and analytical use of modified electrodes for the determination of hydrogen peroxide

Peña, Roselyn Millaray Castañeda 04 November 2011 (has links)
Neste trabalho são apresentados resultados sobre o desenvolvimento de um sensor visando à utilização no monitoramento de peróxido de hidrogênio em amostras de reações Fenton. Superfícies eletródicas modificadas com filmes de poli-azul de metileno (PMB) e óxido de rutênio de hexacianoferrato (RuOHCF) sem e com a incorporação de nanotubos de carbono de paredes múltiplas (MWCNTs) foram utilizadas para a detecção amperométrica de peróxido de hidrogênio. O efeito da ordem de deposição do PMB e MWCNT foi avaliado por voltametria cíclica e espectroscopia de impedância eletroquímica. Estudos realizados por voltametria cíclica indicaram que a superfície modificada com PBM/MWCNTs facilita a redução catódica do peróxido de hidrogênio, processo que ocorre em 0,0 V vs. Ag/AgCl/KCl(sat). O método para a detecção de peróxido de hidrogênio apresentou uma resposta linear de 109 a 3000 &#181;mol L-1, com limite de detecção de 20,7 &#181;mol L-1 e sensibilidade de 108 &#181;A mmol-1 L cm-2. O eletrodo modificado com RuOHCF foi utilizado para a detecção amperométrica de peróxido de hidrogênio por análise em injeção em fluxo (FIA). O método apresentou uma resposta linear de 10 a 5000 &#181;mol L-1 e limite de detecção de 1,7 &#181;mol L-1. Aplicações em amostras comerciais também foram realizadas, e os resultados foram concordantes com os obtidos por método padrão. Estudos sobre o processo eletrocatalítico da reação de peróxido de hidrogênio em filmes de RuOHCF foram investigados utilizando eletrodo rotativo. A incorporação de MWCNTs na superfície eletródica também foi analisada com o filme de RuOHCF. Os resultados indicaram que a presença de MWCNTs melhorou a resposta do sensor para peróxido de hidrogênio em potenciais próximos a 0,0 V vs. Ag/AgCl/KCl(sat). A influência da quantidade de MWCNTs foi avaliada por amperometria em 0,0 V vs. Ag/AgCl/KCl(sat) na presença de peróxido de hidrogênio. O eletrodo modificado com 100 &#181;g de MWCNTs e posterior deposição do filme de RuOHCF apresentou melhores características analíticas. Obteve-se como resultado uma curva analítica em um intervalo de 0,1 a 10 mmol L-1, originando uma reta de acordo com a equação: -I (&#181;A) = 0,26 + 31,2 [H2O2] (mmol L-1), R2= 0,9999. A sensibilidade foi de 1560 &#181;A mmol-1 L cm-2 e os limites de detecção e quantificação foram estimados em 4,7 (S/N = 3) e 15,8 (S/N = 10) &#181;mol L-1, respectivamente. Comparando-se as características analíticas dos filmes de PMB e RuOHCF depositados na superfície dos MWCNTs, aquele que apresentou melhor resultado foi o eletrodo modificado com MWCNTs e RuOHCF por ter melhor limite de detecção e maior sensibilidade. Esse eletrodo modificado com MWCNTs e RuOHCF foi utilizado para monitorar o consumo de peróxido de hidrogênio em amostras de reação Fenton. Também foi avaliado o efeito da presença de Fe3+ contido no próprio processo de degradação. A interferência foi eliminada complexando o Fe3+ com oxalato. Finalmente, o eletrodo foi utilizado para monitorar a concentração de peróxido de hidrogênio na degradação de fenol e os resultados foram concordantes com os obtidos por método espectrofotométrico / This work presents results on the development of a sensor to monitor the hydrogen peroxide content in samples of Fenton reaction. The electrode surface was modified with films of poly-methylene blue (PMB) and ruthenium oxide hexacyanoferrate (RuOHCF). In some cases, multiwalled carbon nanotubes (MWCNT) were also used. The effect of the order of deposition of PMB and MWCNTs was evaluated by cyclic voltammetry and electrochemical impedance spectroscopy. The influence of immobilization of various platforms in the performance of fabricated sensors for hydrogen peroxide was also studied. Cyclic voltammetry experiments indicated that the surface modified with PMB/MWCNTs facilitates the cathodic reduction of hydrogen peroxide, a process that occurred at 0.0 V vs. Ag/AgCl/KCl(sat). The method showed a linear response from 109 to 3000 &#181;mol L-1 hydrogen peroxide. The limit of detection was estimated as 20.7 (S/N = 3) &#181;mol L-1 with a sensitivity of 108 &#181;A mmol-1 L cm-2. Electrodes modified with RuOHCF films were used for the amperometric detection of hydrogen peroxide by flow injection analysis (FIA).The method showed a linear response from 10 to 5000 &#181;mol L-1 and a detection limit of 1.7 &#181; mol L-1. Analyses of hydrogen peroxide in commercial samples were also performed, and the results agreed with those obtained by a standard method. Studies on the kinetics of the electrocatalytic reduction of hydrogen peroxide in RuOHCF films were carried out using rotating disc voltammetric. The immobilization of MWCNTs on RuOHCF films was also investigated. The results indicated that the presence of MWCNTs facilitated the electrocatalytic reduction of hydrogen peroxide at potential values near to 0.0 V vs. vs. Ag/AgCl/KCl(sat). The influence of the amount of MWCNTs was studied by amperometry at 0.0 V vs. vs. Ag/AgCl/KCl(sat) in the presence of hydrogen peroxide. The electrode modified with 100 &#181;g of MWCNTs and subsequent deposition of the RuOHCF film showed better analytical characteristics. An analytical curve ranging from 0.1 to 10 mmol L-1 hydrogen peroxide was obtained, resulting in a straight line according to the equation: -I (&#181;A) = 0.26 + 31.2 [H2O2] (mmol L-1), R2= 0.9999. The sensitivity was found to be 1560 &#181;A mmol-1 L cm-2 and the detection and quantification limits were estimated at 4.7 (S / N = 3) and 15.8 (S / N = 10) mmol L-1, respectively. Electrodes modified with MWCNTs and RuOHCF films leaded to better detection limit and sensitivity in comparison to those modified with MWCNTs and PMB. This MWCNTs and RuOHCF modified electrode was used to monitor the consumption of hydrogen peroxide in samples of Fenton reaction and the effect of Fe3+ generated in the degradation process was also examined. The interference was minimized by adding oxalate to the samples. Finally, the sensor was used to monitor the concentration of hydrogen peroxide in the degradation of phenol and the results were in agreement with those obtained by using spectrophotometry
818

NADH desidrogenase mitocondrial de Trypanosoma cruzi: subunidade 7 para diagnóstico diferencial de isolados humanos e análise funcional. / Mitochondrial NADH dehydrogenase of Trypanosoma cruzi: subunit 7 for differential diagnosis of human isolates and functional analysis.

Martinez, Julio César Carranza 07 October 2008 (has links)
Na fase crônica da doença de Chagas, 70% dos pacientes são assintomáticos, 20-30% apresentam a forma cardíaca e 8% a digestiva. A influência da heterogeneidade genética das cepas de Trypanosoma cruzi na evolução da forma clínica foi cogitada. Neste trabalho, utilizamos PCRs para genes do maxicírculo de T. cruzi para caracterizar parasitas isolados de 75 pacientes com a forma assintomática ou cardíaca. Verificamos que os genes que codificam as subunidades 7 (ND7) e 4 (ND4) da NADH desidrogenase (complexo I mitocondrial) apresentam deleções em algumas cepas. No entanto, não observamos correlação entre as deleções nos genes e as formas clínicas. Investigamos alguns parâmetros do funcionamento da mitocôndria em cepas controle e com mutações. Verificamos que as deleções em ND7 ou ND4 não afetam a velocidade de consumo de oxigênio em epimastigotas permeabilizados com digitonina, concluindo que o complexo I mitocondrial não é funcional neste estágio. Observamos que os níveis de produção de H2O2 pela mitocôndria não guardam relação com a presença das mutações. / In the chronic phase of Chagas disease, 70% of the patients are asymptomatic, 20-30% develop the cardiac form and 8% the digestive form. The influence of the genetic heterogeneity of Trypanosoma cruzi strains in the outcome of the clinical presentation has been considered. In this study, we employed PCR assays targeted to T. cruzi maxicircle genes to genotype parasite isolates from 75 patients with the asymptomatic or cardiac forms. We verified that the genes that code for subunits 7 (ND7) and 4 (ND4) of the NADH dehydrogenase (mitochondrial complex I) show deletions in some strains. Nevertheless, we found no correlation between the presence of the deletions and the clinical presentations. We investigated some mitochondrial functional parameters in control and mutant strains. We observed that deletions in ND7 or ND4 do not affect the rate of oxygen consumption in epimastigotes permeabilized with digitonin. We conclude that complex I is non-functional in this stage. We observed no correlation between mitochondrial production of H2O2 and the gene deletions.
819

Efeito de antioxidantes na resistência adesiva à microtração do esmalte bovino clareado após 7 dias e 6 meses de armazenamento / Effect of antioxidants on bleached enamel microtensile bond strength after 7 days and 6 months storage

Falcão, Marina Studart Alencar 28 February 2013 (has links)
Este estudo in vitro avaliou o efeito do bicarbonato de sódio 10% (BS) e do hidrogel de ascorbato de sódio 10% (AS) na resistência adesiva à microtração de uma resina composta unida à superfície de esmalte bovino clareado com peróxido de hidrogênio 35% (PH). Cento e vinte superfícies de esmalte vestibular com dimensões de 4mmX4mm de incisivos bovinos foram planificadas e separadas em cinco grupos: C - não clareado e restaurado; OI - clareado com PH e restaurado imediatamente; O7 - clareado com PH, armazenado por 7 dias em água destilada e restaurado; OBS - clareado com PH, BS 10% durante 5 min e restaurado; OAS - clareado com PH, AS 10% durante 15 min e restaurado. O gel de PH (Total Blanc Office, Nova DFL) foi aplicado duas vezes de 20 minutos em cada espécime e as restaurações foram confeccionadas com sistema adesivo restaurador (Natural Bond DE + Natural Look, Nova DFL). Após uma semana, os espécimes foram seccionados para obtenção de palitos com 1,00 mm2 de área média e submetidos ao teste de microtração em máquina de teste universal a 0,5mm/min, imediatamente e após 6 meses. As falhas foram avaliadas em estereomicroscópio digital (200x) e classificadas em: adesiva, coesiva em esmalte, coesiva em resina e mista. Os dados foram analisados por ANOVA a dois critérios e teste de Tukey para comparações múltiplas (p<0,05). Os valores médios de resistência adesiva (MPa ± DP; imediatamente / 6 meses) foram: C (24,22 ± 7,74 Ba / 20,13 ± 6,43 BCa); OI (18,29 ± 5,88 Ca / 25,85 ± 5,23 Ab); O7 (40,88 ± 7,95 Aa / 24,61 ± 7,83 ABb); OBS (19,95 ± 5,67 BCa / 15,94 ± 5,57 CDa); OAS (24,43 ± 6,43 Ba / 13,69 ± 5,58 Db). Das estratégias antioxidantes avaliadas após 7 dias, os grupos OAS e OBS não diferiram estatisticamente do grupo C, nem OBS diferiu estatisticamente do grupo OI. Nesse período de avaliação, somente o grupo O7 apresentou diferença significativa em relação aos demais grupos. Após 6 meses de envelhecimento, apenas O7 e OBS apresentaram desempenho semelhante estatisticamente ao grupo C. O percentual de falhas (7 dias / 6 meses) foi: adesiva (65,26% / 67,06%); coesiva em esmalte (14,74% / 24,71%); coesiva em resina (1,58% / 2,35%); mista (18,42% / 5,88%). Em função dos resultados apresentados, a estratégia mais segura é aguardar 7 dias após o clareamento para a realização de restaurações adesivas. Quando não for possível aguardar este tempo, a aplicação de bicarbonato de sódio 10% por 5 minutos sobre o esmalte clareado deve ser feita. / This \"in vitro\" study evaluated the effect of 10% sodium bicarbonate (SB) and 10% sodium ascorbate (SA) hydrogel on the composite resin microtensile bond strength of bleached bovine enamel with 35% hydrogen peroxide (HP). One hundred and twenty buccal enamel surfaces with dimensions of 4mmX4mm of bovine incisors were flattened and separated into five groups: C - not bleached and restored, OI - bleached with HP and immediately restored; O7 - bleached with HP, stored for 7 days in distilled water and restored; OBS - bleached with HP, 10% SB for 5 min and restored; OAS - bleached with HP, 10% SA for 15 min and restored. HP gel (Total Blanc Office, Nova DFL) was applied twice for 20 minutes on each specimen and the restorations were performed with an adhesive restorative system (Natural Bond DE + Natural Look, Nova DFL). After a week, the specimens were sectioned into sticks with a 1.00 mm2 average area and submitted to a microtensile test in a universal testing machine at 0.5 mm/min, immediately and after 6 months. The failures were evaluated in a digital stereoscope (200x) and classified as: adhesive, cohesive in enamel, cohesive in resin and mixed. Data was analyzed by two-way ANOVA and Tukey\'s test for multiple comparisons (p <0.05). The average values of the bond strength (MPa ± SD; immediately / 6 months) were: C (24.22 ± 7.74 Ba / 20.13 ± 6.43 BCa) OI (18.29 ± 5.88 Ca / 25.85 ± 5.23 Ab); O7 (40.88 ± 7.95 Aa / 24.61 ± 7.83 ABb), OBS (19.95 ± 5.67 BCa / 15.94 ± 5.57 CDa), OAS (24.43 ± 6.43 Ba / 13.69 ± 5.58 Db). Among the antioxidant strategies evaluated after 7 days, the OAS and OBS groups did not differ from group C and neither OBS group differed from the OI group. In the same evaluation period, only the O7 group presented a significant difference compared to the other groups. After 6 months of aging, only the O7 and OBS groups performed statistically similar to group C. The percentage of failures (7 days / 6 months) was: adhesive (65.26% / 67.06%); cohesive in enamel (14.74% / 24.71%); cohesive in resin (1.58% / 2.35%); mixed (18.42% / 5.88%). According to the results presented, the safety strategy is waiting 7 days after bleaching for the adhesive restorative procedures. When this waiting period is not possible, 10% sodium bicarbonate should be applied for 5 minutes on the bleached enamel.
820

Produção de hidrogênio e ácidos orgânicos por fermentação acidogênica em reator anaeróbio de leito fluidificado / Hydrogen and volatile fatty acids production by acidogenic fermentation in anaerobic fluidized bed reactor

Shida, Gessia Momoe 28 April 2008 (has links)
A matéria orgânica presente nas águas residuárias representa uma matéria prima barata para integrar o processo de digestão anaeróbia e gerar fontes de energia alternativas, como o hidrogênio. O hidrogênio pode substituir os combustíveis fósseis não renováveis e diminuir as emissões de gases do efeito estufa responsável por grande parte da mudança climática global. A combustão do hidrogênio com o oxigênio produz somente vapor d\'água e representa 2,75 vezes mais conteúdo de energia que qualquer hidrocarboneto. Além disso, os ácidos orgânicos gerados no processo podem ser utilizados como fonte de carbono para a produção de metano, hidrogênio por organismos fototróficos e biopolímeros e, para a remoção de nutrientes biológicos. A produção de hidrogênio tem sido estudada em reatores de crescimento suspenso e de crescimento imobilizado como o reator anaeróbio de manta de lodo (UASB), reator anaeróbio de leito fixo e reator anaeróbio de leito fluidificado. O objetivo desse estudo foi avaliar a produção de hidrogênio e ácidos orgânicos em um reator anaeróbio de leito fluidificado contendo argila expandida como material suporte. O reator tinha 190 cm de altura, 5 cm de diâmetro interno e um volume de 4192 \'CM POT.3\'. O reator foi inoculado com lodo pré-tratado termicamente a 90°C por 10 minutos para o enriquecimento do inóculo acidogênico. O sistema foi operado com tempo de detenção hidráulica (TDH) de 8, 6, 4, 2 e 1 h e foi alimentado com água residuária sintética contendo 2000 mg/L de glicose. A operação contínua teve duração de 178 dias, e em cada TDH o reator foi operado durante, aproximadamente, 30 dias. A 30°C e pH de 3,8, cerca de 92 a 98% da glicose foi removida. A diminuição do TDH de 8 para 1 h conduziu a um aumento na velocidade média de produção de hidrogênio volumétrico de 0,28 para 1,15 L/h.L, respectivamente. A máxima velocidade de produção de hidrogênio, de 1,15 L/h.L, foi obtida em TDH de 1 h. Em geral, o rendimento de produção de hidrogênio aumentou com a diminuição do TDH, de 1,84 mols \'H IND.2\'/mol glicose em TDH de 8 h para 2,29 mols \'H IND.2\'/mol glicose em TDH de 2 h. O biogás não continha metano e o conteúdo máximo de hidrogênio foi de 37% em TDH de 2 h. Foi observada uma correlação linear entre a velocidade de produção de hidrogênio e a taxa de carregamento orgânico (TCO). Ainda, a TCO máxima de 104 kg/\'M POT.3\'.d não inibiu a produção de hidrogênio. Os maiores metabólitos solúveis foram o ácido butírico (44,64-52,52%) e o ácido acético (41,17-47,48%) com insignificante concentração de etanol (menor do que 10%). A produção de hidrogênio estável e a porcentagem de ácido butírico sobre o ácido acético indicam que o tratamento térmico do lodo foi efetivo e uma típica fermentação do tipo ácido butírico pode ser assegurada por Clostridium. Além disso, foram alcançados bons desempenhos de produção de hidrogênio sob condições de pH em torno de 4,0. / Organic materials in the wastewater can be an inexpensive raw material for integrating fermentation process and suppling renewable energy source such as hydrogen. Nevertheless hydrogen can replace fossil fuels and reduce greenhouse gases responsible for global climate change. The hydrogen combustion with oxygen produces only water vapor and hydrogen gas has 2.75 times the energy content of any hydrocarbons. Furthermore, the volatile fatty acids production can be used as carbon source for methane, photosynthetic hydrogen, bioplastics production and biological nutrients removal. The hydrogen production was carried out in suspend cell system, anaerobic sludge blanket reactor, fixed bed reactors and fluidized bed reactors. The objective of this study was to evaluate the hydrogen and volatile fatty acids production in an anaerobic fluidized bed reactor containing expanded clay like a material to immobilize acclimated anaerobic sludge. The reactor has presented 190 cm high, 5 cm in internal diameter and volume of 4192 \'CM POT.3\'. The reactor was seeded with a heat treated sludge at 90°C for 10 minutes for enriching \'H IND.2\' producing inoculum and supressing methanogens. The system was operated at hydraulic retention time (HRT) of 8, 6, 4, 2 and 1 h and was fed with syntetic wastewater containing 2.000 mg glucose/L. The continuous operation lasted 178 days, and in each TDH the reactor was operated for approximately 30 days. At 30°C and pH 3.8, about 92-98% of glucose was removed. The decrease of HRT from 8.0 to 1.0 led to a marked increase in the mean volumetric hydrogen production rate from 0.28 to 1.15 L/h.L, respectively. The maximum volumetric hydrogen production rate, 1.15 L/h.L, was obtained at HRT of 1.0 h. In general, the hydrogen yield increase from 1.84 mol \'H IND.2\'/mol glucose at HRT of 8.0 h to 2.29 mol \'H IND.2\'/mol glucose at HRT of 2.0 h. The biogas was free methane and the hydrogen content accounted for 37% at HRT of 2.0 h. There was a linear correlation between the hydrogen production rate and the organic loading rate (OLR) and the maximum OLR, 104 Kg/\'M POT.3\'.d, is not expected to inhibit hydrogen production. The major soluble products were butyric acid (44.64- 52.52%) and acetic acid (41.17-47.48%) further ethanol was relatively insignificant (less than 10%). The stable hydrogen production and the percentagen of butyric acid over acetic acid indicated the heat treated sludge was effective and a typical butyrate type fermentation was achieved by Clostridium. In addition, hydrogen production could be performed under pH conditions near 4.0.

Page generated in 0.0768 seconds